Home

User Manual S9910 GPRS/CDMA DTU

image

Contents

1. gt 1 S9910 DTU S9910 DTU RS232 n TTE User Device Registry Server Integrated or third party User Mobile Device Since H7000 wireless DDN system has been operated for many years in China it proves that the system is widely applied and works stably The system is a dedicated ideal data transmission channel for industrial applications The manual explains setup procedure of S9910 DTU and provides the system operation guide 1 2 System Features Basic Features GPRS Part m Support dual band GSM GPRS m Complies with ETSI GSM Phase 2 Standard m Real time clock CDMA Part m Support 800 1900MHz band m Complies with FCC SAR and CDG 1 283 m Real time clock Enhanced Features Transparent data transmission and protocol conversion Always online and operation mode selection Support the virtual private data network Support data service center dynamic IP address and domain name STK or UTK card function configuration Support TTL RS 232 422 485 or Ethernet data interface Support voice interface System maintenance and configuration interface Support UGI based remote configuration and maintenance integrated with data service center Support multiple data service center IP address and domain name 1 0 1 1 1 1 system cascading Option SMS backup channel Option Support system upgrade from radio Option Xmodem interface software upgrade Diagnostic and alarm output M80 771001 01 3 RICON S991
2. sscssssssssrssssessssessessssessessssessessssessessesessassssessasessessessssessassesessesessesees 4 1 5 SPECIFICATIONS sscssssssssssssessessssessessssessessrsessessssessessesessesessessessssesseseesessesersesees 5 1 6 TYPE DESCRIPTION onenn inn nenn RRR RORE RERA 6 CHAPTER2 INSTALLATION 509008 0n 590 aaa danas naas anan akena andana 7 2 1 GENERAL one ana anna agan aan ga ENDANG GONG TANGANE NANGGENAH OKT NGANAN ANGEN Kene 7 2 2 OPEN BON 7 2 3 INSTALLATION AND CABLE CONNECTION 8 2 4 GROUNDING cccsssrsssssersessrsersessrsessesersessessnsessesersessessssnssesensessesensessesensnssssensesseses 12 2 5 POWER SUPPLY s ssssssssssssersessrsersessrsessessnsessesessessessssessssessessesessessesessnssesenseseeses 12 2 6 CHECK THE MOBILE NETWORKNLK 12 CHAPTER 3 DTU SETUP nengna rana adep anaa naba nang anaa naba a ga aaa ana naba nangani 13 3 1 SETUP CONNECTION A au a u a tnnt tata satiata NGANAN KENAA ABANGAN 13 3 2 PARAMETERS CONFIGURA TIONN 13 3 2 1 DTU CONFIGURATION QC cscsssssssssssessrsesssssrsessessssessessrsesseseseessessrssseseseeseeses 14 3 2 2 MODULE TEST T sssssssssrssssrserssssrsessssssessessrsessessreessessssessesessessesenenssesereeseeses 31
3. gt DTU Communication Port At Data Terminal Unit DTU Setup status press 3 to enter the DTU Communication Port sub menu and then the below information will be listed Follow the prompt information to change the DTU communication port If the DTU communication port is less than 5 characters press Enter key to confirm HDOS gt 3 Current Local Communication Port 5001 Change Local Communication Port 50000 This is the DTU data communication port the default setting is 5001 It corresponds with DSC setting Normally we do not recommend changing this setting gt DTU Online Report Interval At Data Terminal Unit DTU Setup status press 4 to enter the DTU Online Report Interval sub menu and then the below information will be listed Follow the prompt information to change the DTU online report interval The options are 0 3 65535 seconds HDOS gt 4 Current Online Report Interval 40 Change Online Report Interval 0 3 65535 s 100 The DTU Online Report Interval is the link maintenance parameter it is a heartbeat package transmission interval As we know the mobile network will disconnect mobile terminal if it does not transmit traffic data for the specified period Therefore the DTU should send a heartbeat package to DSC periodically to keep it alive The heartbeat package is an UDP package it may be charged You should set a correct interval based on your application requirements We recommend setting the int
4. Copyright 2005 Ricon Technologies Co Ltd Released Dec 18 2004 M80 771001 01 34 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup 3 2 6 Reset R S9910 DTU is ready to work when you have finished all settings described at paragraph 3 2 1 and checked it without error At Main Menu status press R or re power S9910 DTU below information will be displayed at HyperTerminal HDOS gt R HDOS gt Ricon H7000 DTU Software 3 0 1 Built On Aug 05 2004 HW3 0M Module Power On mtu 256 rval 40 ttl 180 delay 0 debug 1 mt 1 log 0 wd 1 tx1 0 DTU identity number 13812345678 Service Code g99 1 z PPP Username DSC IP 0 0 0 0 DSC Domain Name www riconmobile com DSC Port 5002 DNS IP 202 96 134 133 Access Point Name CMNET Attach DTU to GPRS service 1 HD NCP negotiation re started 40 Try to logon mobile net Welcome to Ricon GPRS DTU Set Primary DNS server to 211 136 20 203 Set Secondary DNS server to 211 136 20 203 Set DTU IP to 10 103 44 130 Searching DSC 0 1 Set DSC IP to 210 21 197 10 Registering at DSC 210 21 197 10 1 DTU 13812345678 register ok Transparent data service is ready now At previous setting the Console Info Type is set to 1 to display the above information If it is set to 0 the commission information will be closed We recommend setting it to 1 for commissioning and setting it to 0 before putting the DTU into service Up to now we have finished S9910 DTU config
5. DSC Domain Name www mdtu com DSC Domain TTL 180 DSC Communication Port 30066 DNS IP Address 202 96 134 133 Secondary DSC IP Address 0 0 0 0 Secondary DSC Communication Port 5005 4 Serial Port Setup At DTU Configuration status press 4 to list the Serial Port Setup sub menu HDOS gt 4 Serial Port Setup Baud Rate Data Bits Parity Bit Stop Bit Flow Control Return gt Baud Rate At Serial Port Setup status press 1 to enter the Baud Rate sub menu and then the below information will be listed Press 1 to 8 to select the required rate If the rate is not listed at the menu press 9 to enter the Custom setting and then type your specified data rate Press R to return HDOS gt 1 300 bps 1200 bps 4800 bps 9600 bps 19200 bps 38400 bps 57600 bps 115200 bps Custom Return 1 2 3 4 5 6 7 8 9 R gt Data Bits At Serial Port Setup status press 2 to enter the Data Bits sub menu and then the below information will be listed Follow the prompt information to set the data bits M80 771001 01 24 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup HDOS gt 2 Current Data Bits 8 Change Data Bits 6 8 8 gt Parity Bit At Serial Port Setup status press 3 to enter the Parity Bits sub menu and then the below information will be listed Follow the prompt information to set the parity bits HDOS gt 3 1 None 2 Odd 3 Even R Return Stop Bit At Serial Po
6. 3 2 3 ADVANCED FUNCTION F cscsssssssssssssrsesssssrsesscssssnssessssessessnsessesessnssesenseseeses 32 3 2 4 DISPLAY SETTING D sengeng in sanane a gang ie nana naa tata sint ta tasse nn a 33 3 2 5 VERSION INFO V gasss aaa esee eese estne tata on Tanos rin uN er R UNG Urr N teta sisse UKRINE FENES 34 kMOnn 35 CHAPTER 4 OPERATION eeeeeeee tana inane rana iorsin keanan sese snae tn i 36 4 1 PANEL INDICATIONS e 409094 0805890585 9005 5059 05 sata tasa totas n ete ta 559 tasas tata sn enn 36 4 2 DTU OPERATION GUIDANCE 36 4 3 TROUBLE SHOOTING eese esee Wa srini ai n e kasusqa tasse aN 37 APPENDIX HYPERTERMINAL SETTING 39 RICON S9910 GPRS CDMA DTU User Manual Chapter 1 Introduction Chapter 1 Introduction This chapter introduces the 9910 GPRS CDMA DTU descriptions features and philosophy General System Features System Components Philosophy Specifications Types Description Pv pb de 3 poor 1 1 General Along with mobile communication technology s development the GPRS and CDMA 1x data networks have covered all country this brings a bright future for industrial applications Requirements towards information system are varied because of different features of numerous industrial applications Mobile
7. Configuration status press 2 to list the Data Terminal Unit DTU Setup sub menu HDOS gt 2 Data Terminal Unit DTU Setup DTU Identity Number Logon DSC Password DTU Communication Port DTU Online Report Interval DTU Maximum Transmission Unit DTU Reconnect Interval Console Info Type Last Packet Idle Interval Identifier separator User defined Heartbeat Return Z0u0 0Ulh UNH gt DTU Identity Number At Data Terminal Unit DTU Setup status press 1 to enter the DTU Identity Number sub menu and then the below information will be listed Follow the prompt information to change the DTU identity number If the DTU identity number is less than 11 characters press Enter key to confirm HDOS gt 1 Current DTU Identity Number 20000000003 Change DTU Identity Number 13812345678 gt Logon DSC Password At Data Terminal Unit DTU Setup status press 2 to enter the Logon DSC password sub menu and then the below information will be listed Follow the prompt information to input 6 characters password HDOS gt 2 Input New DSC Password Confirm New DSC Password M80 771001 01 17 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup Notice For the security consideration the password may be required when the DTU logs on DSC Therefore you can set it at this menu The password is defined at DSC software N A for this version The password is 6 characters Default password is 123456 or null
8. be connected correctly We suggest double check before switch it on Wrong connections may destroy the equipment Power terminals Pin 11 and Pin 12 Here Pin 11 is GND Pin 12 is power input Vin 7 5 26VDC 9910C DTU RS 232 interface and power supply illustration 9910 DTU DCE RS 232 DB9 DTE 1 2 3 4 5 6 7 8 RING 9 GND 10 GND 11 Vin 12 Vin GND RS 232 signal definition Pin Signal Description Note 1 DCD Carrier Detection 2 RX Receive Data 3 TX Transmit Data 4 GPI General Purpose Input 5 OFF Power Off Control 6 GPO General Purpose output 7 RTS Request to Send 8 CTS Clear to Send 9 RING Ring Signal 10 GND Ground 11 GND Ground 12 Vin 7 5 26V DC Input Current 350mAQ 12V RS 232 interface complies the standard RS 232 specification M80 771001 01 10 S9910 GPRS CDMA DTU User Manual Chapter 2 Installation S9910F DTU RS 422 interface and power supply illustration S9910 DTU RS 422 User Side R R GPI OFF GPO T T RING GND 10 GND 11 Vin 12 OON OA Ul UNGAE Vin GND S9910S DTU RS 485 interface and power supply illustration S9910 DTU RS 485 User Side D 0 sJ OA On 4 QON P Vin GND RS 422 485 signal definition Pin Signal Description Note 1 2 T A Transmit Data A RS 485 TX RX 3 T B Transmit Data B RS 485 TX RX 4 GPI General Pur
9. configured at other rate for communicating with DTU However it must be set at 57600baud to enter the DTU configuration menu FK K CK K K CK CK K CK lt x OK CK K x CK x K CK x X x X OK X X x CE x OK x x CE K CE K K K OK K K CE K K K K K H7000 DTU Management Tools 2 C Hardware HW3 0M Copyright C 2003 2008 Ricon Inc DTU Series Number gt PK PK CK CK CK OK OK K x PK CK CK CK lt OK KK x K CK CK CE x K K OK x CK CK x K K K OK OK OK OK K K K K K K Type H or for help Press D to Display the configuration parameters HDOS gt Type H or the main menu will display on your PC screen H7000 DTU Management V3 0 1 C DTU Series No DTU Configuration C Module Test T Advanced Function F Version V Reset R DOS gt 3 2 1 DTU Configuration C At Main Menu status press C to enter the DTU configuration sub menu You may be required to input a correct password M80 771001 01 14 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup Ricon gt C Password S9910 DTU factory default password is 1234 Refer to this paragraph menu 6 descriptions you can modify it with your favor Type a correct password and press Enter key the below sub menus will be listed at HyperTerminal DTU Configuration Mobile Service Center MSC Setup Data Terminal Unit DTU Setup Data Service Center DSC Setup Serial Port Setup Special Setup Set DTU Password Default Setting Return 1 2 3
10. its setting Second M80 771001 01 27 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup gt Set Offline Interval At Special Setup status press 4 to enter the Set Offline Interval sub menu and then the below information will be listed Follow the prompt information to set the offline interval The options are 0 10 65535 seconds Press R to return HDOS gt 4 Current Offline Interval 0 Change Offline Interval 0 10 65535 s 0 This is the parameter to control DTU offline DTU will goes offline after it is idle for the set time Setting 0 is the meaning that DTU will not go offline Other interval corresponds with its idle time setting Second gt DSC Identity Number At Special Setup status press 5 to enter the DSC Identity Number sub menu and then the below information will be listed Follow the prompt information to set the DTU identity number in DSC We recommend setting it with associated SIM or UIM card number Press R to return HDOS gt 5 Current DSC DTU Identity Number Change DSC DTU Identity Number DSC Identity Number is valid at MTT setting 2 For example if the DSC Identity Number is set to 13612345678 the DTU will only be online when it is called by the 13612345678 caller The SIM UIM should support caller ID function If the DSC Identity Number is set to blank the DTU will accept calling from anyone It can be set accordingly gt Communication Protocol Option None 0 DDP 1 At Sp
11. 0 GPRS CDMA DTU User Manual Chapter 1 Introduction EMC EMI design Power management for wide range power input Industrial class pluggable terminal for signal connections 1 3 System Components 1 4 Philosophy H7000 wireless DDN system consists of DTU there are following types can be selected in accordance with specified applications H7111 GPRS DTU TTL data interface built in design H7112 GPRS DTU RS 232 422 485 data interface H7118 GPRS DTU RS 232 422 485 data interface high performance H7161 GPRS DTU Ethernet interface H7611 CDMA DTU TTL data interface H7612 CDMA DTU RS 232 422 485 data interface H7661 CDMA DTU Ethernet interface S9910 CDMA 1x DTU RS 232 422 485 data interface platform designed with customer specified options Data service center There are two options for customer applications H7030 wireless DDN data service center development pack provides classes functions packages and the ActiveX controls Meanwhile Virtual Serial Port Divers can be provided for existing system selections H7036 wireless DDN data service center router it transfers the user data and converts the transmission protocol it can be connected with the broadband network access and the GPRS CDMA 1x network to transmit and convert the data from to GPRS CDMA DTU and then transmit the data to user application data service center S9910 DTU is a product working at cellular data network to provide data service for industria
12. 0 seconds and set it longer than DTU Online Report Interval DSC IP Address and domain name should be configured in accordance with your network planning If a static IP address is available at your server site we recommend setting DSC IP Address at this IP address If it is not set a valid DSC domain name and the DSC IP Address should be null 0 0 0 0 Meanwhile the DNS IP Address should be configured Contact with Ricon support department for more information DSC Communication Port At Data Service Center DSC Setup status press 3 to enter the DSC Communication Port sub menu and then the below information will be listed Follow the prompt information to set the DSC Communication Port Press Enter by to confirm HDOS gt 3 Current DSC Communication Port 5002 Change DSC Communication Port 30066 This is the DSC data communication port the default setting is 5002 You can change it with your system planning gt DNS IP Address At Data Service Center DSC Setup status press 4 to enter the Internet DNS IP Address sub menu and then the below information will be listed Follow the prompt information to set an Internet DNS IP Address HDOS gt 4 Current DNS IP Address 202 96 134 133 Change DNS IP Address 202 96 134 133 M80 771001 01 22 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup The default DNS is Shenzhen DNS address You can modify it according to the local information If the DSC Domain Name i
13. 0123456789 Access Point Name shenzhen0123456789012345 2 Data Terminal Unit DTU Setting DTU Identity Number 13812345678 Local Communication Port 50000 DTU Online Report Interval 100 DTU Maximum Transmission Unit 1000 DTU Reconnect Interval 0 Console Info Type 1 Last Packet Idle Interval 600 Match Char OD 3 Data Service Center DSC Setting DSC IP Address 210 21 197 10 DSC Domain Name www mdtu com DSC Domain TTL 180 DSC Communication Port 30066 DNS IP Address 202 96 134 133 4 Serial Port Setting Baud Rate 57600 Data Bits 8 Stop Bit 1 Parity Bit None Flow Control None 5 Special Setting Mobile Terminal Type 0 Call Type 1 Call Interval 60 Offline Interval 0 DSC Identity Number 13612345678 HDOS gt M80 771001 01 33 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup 3 2 5 Version Info V At Main Menu status press V to list Version Info sub menu HDOS gt v Version Info 1 DTU Software Version 2 DTU Management Tools Version R Return 1 DTU Software Version At Version Info status press 1 to display the DTU Software Version HDOS gt 1 H7000 DTU Software V3 0 1 Copyright 2005 Ricon Technologies Co Ltd Released Dec 18 2004 2 DTU Management Tools Version At Version Info status press 2 to display the DTU Management Tools Version HDOS gt 2 H7000 DTU Management Tools V3 0 1 C
14. 31 means the highest signal To ensure the stable communication the RF signal should be up to 10 If it is less this level we recommend installing a high gain antenna to increase its receiving signal 2 Activate GPRS Mode GPRS example At Module Test status press 2 to activate GPRS mode HDOS gt 2 Activating GPRS Mode Please waiting OK means the activation successful ERROR means the activation failed No echo means failed also 3 Search GPRS Module M80 771001 01 31 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup At Module Test status press 3 to search GPRS module HDOS gt 3 Searching GPRS Module Please waiting Find GPRS Module The result may be Find GPRS Module or Can t find GPRS Module 4 Test GPRS Module At Module Test status press 4 and type AT commands to test GPRS module Notice Incorrect AT command may cause a big problem Read the AT command instructions carefully before executing the command 3 2 3 Advanced Function F It is an advanced function for Ricon contracted developers Contact with Ricon R amp D center for more information M80 771001 01 32 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup 3 2 4 Display Setting D At Main Menu status press D to display DTU all settings HDOS gt D H7000 DTU Configuration List 1 Mobile Service Center MSC Setting Service Code 99 1 PPP Username 01234567890123456789
15. 4 5 6 7 R HDOS gt 1 Mobile Service Center MSC Setup At DTU Configuration status press 1 to enter the Mobile Service Center MSC Setup sub menu and then the below information will be listed Mobile Service Center MSC Setup 1 Service Code 2 PPP User Name 3 PPP Password 4 Access Point Name APN 5 SIM PIN R Return HDOS gt gt Service Code At Mobile Service Center MSC status press 1 to enter the Service Code sub menu and then the below information will be listed Follow the prompt information to input a correct code If the code is less than 8 characters press Enter key to confirm HDOS gt 1 Current Service Code 99 1 Change Service Code 99 1 M80 771001 01 15 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup gt PPP User Name At Mobile Service Center MSC status press 2 to enter the PPP User Name sub menu and then the below information will be listed Follow the prompt information to change the user name If the user name is less than 30 characters press Enter key to confirm HDOS gt 2 Current Username Ricon Chanae Username 012345678901234567890123456789 gt PPP Password At Mobile Service Center MSC status press 3 to enter the PPP Password sub menu and then the below information will be listed Follow the prompt information to change PPP password If the new password is less than 20 characters press Enter key to confirm HDOS gt 3 Change Passwo
16. 9600baud also But I can not enter S9910 DTU management tools Although the DTU traffic data and management data are transmitted through the same physical port but it is transferred via the different logical channel inside of DTU The serial port setting described at paragraph 3 2 1 is only for the traffic data port It does not affect the management port Therefore your HyperTerminal serial port rate should be set to 57600baud and then press and hold PC Space key to enter the DTU Management Tools M80 771001 01 38 S9910 GPRS CDMA DTU User Manual Appendix HyperTerminal Setting Appendix HyperTerminal Setting This annex introdu the Mirosof Windavs operating system Hyper Temanal setting for the S9910 DTU configuration 1 COM Port Setting 2 Properties 3 Host System Encoding Method 4 ASCII Setting 1 COM Port Setting By Clicking Windows Accessories Communications HyperTerminal to create a HyperTerminal Refer to below picture to continue the settings Connection Description 2 xl A5 New Connection Enter a name and choose an icon for the connection Name H7000 Cancel M80 771001 01 39 S9910 GPRS CDMA DTU User Manual Appendix HyperTerminal Setting Connect To The COM port parameters should be specified Select COM number i e COM2 Bites per second Data bits Parity Stop bits and Flow control COM Properties 67600 Notice Flow c
17. RICON MOBILE CONNECT TECHNOLOGY RICON TECHNOLOGIES CO LTD Mobile Data Communications User Manual MOBILE DATA COMMUNICATIONS S9910 GPRS CDMA DTU User Manual Ricon Technologies Co Ltd Ahi Evran Cad No 1 Polaris Plaza Kat 6 No 32 Maslak istanbul Turkey Tel 90 212 275 95 95 Fax 90 212 346 26 70 Email info riconmobile com Copyright 2004 M80 771001 01 Release 2 8 1 Notice Copyright The contents of the manual are protected by Chinese law any organization and or person cannot copy this manual or part of contents without Ricon Technologies Co Ltd authorization in written Trademark Ricon GPRS DTU CDMA DTU MDTU Wireless DDN Ricon Technologies and Ricon are the logos and trademarks of Ricon Technologies Co Ltd The other company trademarks and logos in this manual are owned by the owner Ricon does not have the right for those trademarks and logos Abbreviations APN APP ATM ATM AuC BG BGP BSC BSCC BSS BSSGP BTS CDMA CDR CGF CSD DDN DHCP DNS DSC DTU EGP EIGRP EMC ESP ETSI GGSN GMSC GPRS GSM GSN GTP GTP id HLR HSCSD IGMP Access Point Name Application Asynchronous Transfer Mode Auto Table Machine Authentication Centre Border Gateway Border Gateway Protocol Base Station Controller Base Station Control Connection Base Station System BSS GPRS Protocol Base Transceiver System Code Division Multiple Access Call Detail Record Char
18. can check DTU operation and modify the configurations by a GUI based program locally and remotely This management program should be developed and integrated with the customer s application system Ricon provides a SDK for the development Caution To modify the DSC IP Address you have to carefully configure it with a correct DSC IP Address or domain name incorrect IP address or domain name will lose its communication M80 771001 01 36 S9910 GPRS CDMA DTU User Manual Chapter 4 Operation S9910 DTU should be installed at place with good radio signal receiving For the cabinet and basement environment we recommend to extend the antenna For outdoor use lightning should be considered We propose to install an arrester between antenna and the ANT interface Contact Ricon technical support department for details The configuration parameters can be saved at S9910 DTU flash memory or SIM UIM card and the S9910 DTU flash saved settings will be retrieved in higher priority No routine maintenance is required for S9910 DTU operation At embedded application environment the data service center will check DTU operation information 4 3 Trouble Shooting Problem 1 All LEDs do not light up Check all cables that are connected to the DTU Check the power supply adapter output voltage DTU works normally if the PWR LED flash at 1Hz frequency and it is in configuration status if the PWR LED lights up constantly If the power is correct
19. d properly before putting it in service The installation and configuration should be done or supervised by Ricon qualified engineer Attention Do not install S9910 GPRS CDMA DTU or connect disconnect its cable when it is power on In order to protect products during shipment S9910 GPRS CDMA DTU has been packed properly You may need to keep the packing materials for reshipping after you open the pack box S9910 GPRS CDMA DTU package includes e S9910 DTU 1 piece Packed according to P O User Manual 1 copy CD ROM e Qualified amp Repair Card 1 piece Optional Accessories Standard Antenna Vehicle Antenna Directional Antenna 220VAC Adapter Cascading Cable Mini USB Length 80cm H7071 Configuration Cable After you open the box you should count it carefully with your purchase order M80 771001 01 7 S9910 GPRS CDMA DTU User Manual Chapter 2 Installation 2 3 Installation and Cable Connection Measurement S9910 DTU outside measurement and installation position SIWUIM Open top SIM UIM protection cover and then insert SIM or UIM from left top side SIM UIM card conductors should face downside and the gap face to outside The SIM UIM card also need to be inserted properly and then cove back the SIM UIM protection cover in order to prevent the SIM UIM card from dropping out during shipping Slide the SIM UIM card by your finger to take out the SIM UIM card M80 771001 01 8 S9910 GPRS CDMA DTU User Ma
20. de Public Land Mobile Network Point of Sales Point to Multipoint Group Call Point to Multipoint Multicast Quality of Service Routing Area Remote Authentication Dial In User Service Routing Information Protocol Register Service Center Real Time Operating System RIP RTU RSVP SCADA SGSN SIM SMS SMSC SNMP STK TCP TDMA TMN TTL UDP UIM UMTS USSD UTK VLR WAN WAP WDDN Real time Transport Protocol Remote Terminal Unit Resource reSerVation Protocol Supervisory Control and Data Acquisition Serving GPRS Support Node Subscriber Identify Module Short Message Service Short Message Service Center Simple Network Management Protocol SIM Tool Kits Transmission Control Protocol Time Division Multiple Access Telecommunication Managed Network Time to Live User Datagram Protocol User Identify Module Universal Mobile Telecommunication System Unstructured Supplementary Service Data UIM Tool Kits Visitor Location Register Wide Area Network Wireless Application Protocol Wireless Digital Data Network Contents CHAPTER 1 INTRODUCTION cscsssssssssssrsesscssrsesssssrsessssrsessessnsssecsseesseseneeseeses 1 1 1 GENERAL csssssssessssesecssssessessssessessssesscssssessessssessesessessesessessesessessesessessesessessesessesees 1 1 2 SYSTEM FEATURES csssssssssessessssessessssessessssessessssessessssessessssessesessessesessessesessesees 3 1 3 SYSTEM COMPONENTS usiri ainia a 4 1 4 PHILOSOPHY
21. e Network Connect all signal and power cables and double check it connect antenna insert a valid SIM or UIM depends your DTU type and network and switch on power S9910 DTU PWR LED will light up If PWR LED is flashing it means the S9910 DTU is working normally If the DATA LED is flashing it means there are data stream input out over S9910 DTU data port If the NET LED lights up it means that the 9910 DTU has found and logged on mobile network More information refer to Chapter 4 m All cables should be connected correctly before switch on m Antenna should be connected before switch on otherwise it may cause radio module problem M80 771001 01 12 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup Chapter 3 DTU Setup This chapter introduces the 9910 GPRS CDMA DTU hanay configuration before putting it m sera 1 Setup Connection 2 Parameters configuration S9910 GPRS CDMA DTU is built in with a set of DTU Management Tools for DTU configuration management and commissioning Use the tools to configure DTU parameters before putting it in service and change the configurations during system commissioning The tools can also be used to upgrade the DTU software After entering the DTU Management Tools you can configure and manage your system setting in accordance with your system plan Type H or to display the DTU operation menu Press ESC key to discharge the parameters you have typed Press Enter key to conf
22. e Ripple e Consumption m In Use m Idle e Measurement Weight Temperature e Relative Humidity 1 6 Types Description Chapter 1 Introduction 7 5 26VDC 5VDC Optional lt 300mV Mean current 230mMA 12VDC 12mAQ 12VDC 93x54x22 Not include antenna installation pack and connector 230g 25 60 C 95 non condensing 9910 DTU is a product designed at Ricon platform with customer specified application options It complies with the different industrial applications and different service provider mobile data network In order to identify different products we explain the type name as below S9910 DTU type S9910 XYZn S9910 X data Y network Zn Factory and type interface Ricon GPRS CDMA C RS232 C CDMA A AnyData DTU 3 0 platform D TTL G GPRS B BenQ F RS422 E Sony Ericsson S RS485 H Huawei M Motorola S Siemens W Wavecom Z Zhongxin Z factory n radio module type can be null For example S9910 CGM2 RS 232 DCE interface GPRS DTU built in with Motorola G20 radio module M80 771001 01 S9910 GPRS CDMA DTU User Manual Chapter 2 Installation Chapter 2 2 1 General 2 2 Open Box Installation This chapter desribes the 9910 GPRS CDMA DTU installation prowdurs paver on and initial setup General Open Box Installation and Cable Connection Grounding Power Supply Check the Mobile Network SOU Bee S9910 GPRS CDMA DTU should be installed and configure
23. e parameters can be set to meet the dynamic IP address communication It is no necessary to set it for the static IP address data service center application gt Mobile Terminal Type At Special Setup status press 1 to enter the Mobile Terminal Type sub menu and then the below information will be listed Follow the prompt information to set the Mobile Terminal Type The options are 0 2 5 9 Press R to return HDOS gt 1 Current Mobile Terminal Type 0 Change Mobile Terminal Type 0 9 0 The different Mobile Terminal Type MTT setting will boot different software 1 Setting 0 it is compatible with the previous version However it will not activate the radio module first For stable network this type of setting will enhance the online speed M80 771001 01 26 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup 2 Setting 2 DTU is working at user data trigger mode or DSC retrieve mode For this type of setting DTU is offline at normal time and it only log on the mobile network when it detects user data or DSC calling This configuration is suitable for the less data transmission such as transmitting data per hour day or month It will save power and transmission cost 3 Setting 5 it is compatible with the previous version and suitable for unstable network 4 Setting 9 DTU will return the data send from DSC This setting is used for network testing co works with the DTU test tool 5 Others reserved gt Set Ca
24. ecial Setup status press 6 to enter the Communication Protocol Option sub menu and then the below information will be listed Follow the prompt information to set the Communication Protocol Option Press R to return HDOS gt 6 Current transport Type 1 Change transport Type O 1 0 Users can select communication protocols based on application needs the default communications protocol is the DDP the standard TCP IP protocol M80 771001 01 28 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup Packing way is in a transparent manner DDP DTU DSC protocol refers that we increase the Ricon company protocol into the standard TCP IP protocol between the DTU and DSC gt Network Connection Type UDP 0 TCP 1 At Special Setup status press 7 to enter the Network Connection Type and then the below information will be listed Follow the prompt information to set the Network Connection Type Press R to return HDOS gt 7 Current dsc connection type 0 Change dsc connection type O 1 1 users can choose network connection type based on applications the default type is UDP gt TCP Keepalive Interval At Special Setup status press 8 to enter the TCP Keepalive Interval sub menu and then the below information will be listed Follow the prompt information to set the TCP Keepalive Interval Press R to return HDOS gt 8 Current tcp keepalive Interval 5 Change tcp keepalive Interval 0 1 120 m 10 The TCP keepa
25. er defined Heartbeat Hex aa bb 3 Data Service Center DSC Setup At DTU Configuration status press 3 to list the Data Service Center DSC Setup sub menu HDOS gt 3 Data Service Center DSC Setup DSC IP Address DSC Domain Name DSC Communication Port DNS IP Address Backup DSC IP Address Backup DSC Communication Port Return gt DSC IP Address At Data Service Center DSC Setup status press 1 to enter the DSC IP Address sub menu and then the below information will be listed Follow the prompt information to set the DSC IP Address Press Enter by to confirm HDOS gt 1 Current DSC IP Address 210 21 197 10 Change DSC IP Address 210 21 197 10 gt DSC Domain Name At Data Service Center DSC Setup status press 2 to enter the DSC Domain Name sub menu and then the below information will be listed Follow the prompt information to set the DSC Domain Name Press Enter by to confirm The Domain mane TTL Time to Live must be specified when the DSC domain name has been set M80 771001 01 21 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup HDOS gt 2 Current DSC Domain Name www riconmobile com Change DSC Domain Name www riconmobile com Current DSC TTL 180 Change DSC TTL 0 10 65535 s 180 The domain name should be valid and it may not be set if the DSC IP Address is set If the TTL is set to 0 that means the domain name will alive without limitation Normally we recommend setting it at 3
26. erval at 40 seconds for always online application Set it to 0 that means the interval unlimited and DTU will not send heartbeat package Notice If DTU detects data traffic between DTU and DSC within the interval DTU will not send heartbeat package during this heartbeat interval M80 771001 01 18 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup gt DTU Maximum Transmission Unit At Data Terminal Unit DTU Setup status press 5 to enter the DTU Maximum Transmission Unit sub menu and then the below information will be listed Follow the prompt information to change MTU setting The option is 0 1024 bytes HDOS gt 5 Current Maximum Transmission Unit 256 Change Maximum Transmission Unit 0 1024 Bytes 1000 gt DTU Reconnect Interval At Data Terminal Unit DTU Setup status press 6 to enter the DTU Reconnect Interval sub menu and then the below information will be listed Follow the prompt information to set DTU reconnect interval The option is 0 65535 seconds HDOS gt 6 Current Reconnect Interval 0 Change Reconnect Interval 0 65535 s 0 It is the time of reconnection interval Normally DTU will attach to GPRS or CDMA 1x network and then registers to DSC automatically If it is failed the registration DTU will retry at the interval setting If the interval is set to 0 and DTU fails 3 times registration the DTU will reset its software or hardware immediately and retry again If the interval is s
27. et to non 0 and DTU fails 3 times registration the DTU will reset its software or hardware after the reconnect interval and retry again gt Console Info Type At Data Terminal Unit DTU Setup status press 7 to enter the Console Info Type sub menu and then the below information will be listed Follow the prompt information to set the console info type The option is 0 or 1 HDOS gt 7 Current Console Info Type 1 Change Console Info Type 0 1 1 The setting 1 displays operation status information and 0 closes it When you have completed the configuration the Console Info Type should be set to 0 to close the commissioning information M80 771001 01 19 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup gt Last Packet Idle Interval At Data Terminal Unit DTU Setup status press 8 to enter the Last Packet Idle Interval sub menu and then the below information will be listed Follow the prompt information to set the interval The option is 50 65535 ms HDOS gt 8 Current last packet idle Interval 600 Change last packet idle Interval 50 65535 ms The Last Packet Idle Interval is the waiting time interval for transmitting the data package that is less the MTU If the last package equals to the MTU DTU will transmit it immediately The default setting is 600ms gt Identifier separator At Data Terminal Unit DTU Setup status press 9 to enter the Identifier separator sub menu and then the below informati
28. ge DTU password Type blank new password and press Enter key to delete the old password HDOS gt 6 Input Old DTU Password Input New DTU Password Confirm New DTU Password S9910 DTU factory default password is 1234 Change it after you have logged in Default Setting At DTU Configuration status press 7 to retrieve the factory default setting Follow the prompt information to select Y or N Select Y to retrieve the factory default setting select N to discard the operation HDOS gt 7 Retrieve DTU Default Setting Y N Make sure it is a correct operation before pressing Y Press Y to overwrite all the settings except DTU password DTU ID and DSC ID and then retrieve to the factory default M80 771001 01 30 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup 3 2 2 Module Test T At Main Menu status press T to enter the Module Test sub menu HDOS gt T Test List Test RF Signal Activate GPRS Mode Search GPRS Module Test GPRS Module Return Notice The DTU should be inserted with a valid SIM UIM card and connected with an antenna 1 Test RF Signal At Module Test status press 1 to test and press ESC to return HDOS gt 1 RF Signal Value CSQ 26 99 Figure 0 31 00 indicates the normal RF signal For normal communication the received RF signal should reach 8 31 00 Figure 99 99 indicates no RF signal RF signal indication is divided into 32 levels 0 31 and
29. ging Gateway Function Circuit Switch Data Digital Data Network Dynamic Host Configuration Protocol Domain Name System Data Service Center Data Terminal Unit External Exterior Gateway Protocol External Exterior Internet Group Routing Protocol Electro Magnetic Compatibility Electro Static Precautions European Telecommunications Standards Institute Gateway GPRS Support Node Gateway MSC General Packet Radio Service Global System for Mobile Communications GPRS Support Node GPRS Tunneling Protocol GTP Identity Home Location Register High Speed Circuit Switch Data Internet Group Management Protocol MT MTBF MTTR N A NAS NAT NTP O amp M PAP PCF PDP PDN PDSN PLMN POS PTM G PTM M QoS RA RADIUS RIP RSC RTOS Internet Gateway Routing Protocol Intelligent Network Internet Protocol IP version 4 IP version 6 IP Secure Protocol Integrated Services Digital Network Internet Service Provider Layer 2 Tunneling Protocol Location Area Logical Link Control Mobile Application Part Mobile Domain Name System Mobile Data Terminal Unit Management Information Base Mobile Station Mobile Switching Center Mobile Terminal Mean Time between Failures Mean Time to Recovery Not Applicable Network Access Server Network Address Translation Network Time Protocol Operations amp Maintenance Password Authentication Protocol Packet Control Function Packet Data Protocol Packet Data Network Packet Data Service No
30. irm your setting Refer to the following descriptions for more details 3 1 Setup Connection S9910 DTU should be configured properly before putting into service You can configure and manage DTU parameters by connecting DTU CONN interface to your PC via a configuration cable H7071 it should be ordered separately Also it is possible to access the management tools via the user data interface The below paragraphs are described at user data interface configuration AC Adapter S9910 DTU Configuration Cable Connection 3 2 Parameters Configuration Refer to above connection illustrative diagram connect PC and DTU and create a HyperTerminal HyperTerminal setting refers Appendix The HyperTerminal parameters setting M80 771001 01 13 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup Rate 57600baud Bits abit Parity None Stop Bits 1bit Flow Control None Start a HyperTerminal you have created on you PC and hold your PC SPACE key then power on S9910 DTU The below diagram will appear on your PC screen and then release the SPACE key The HyperTerminal parameters setting refers to described Appendix or Windows operation system manual Notice 1 To enter the S9910 DTU configuration menu you have to press and hold your PC Space key and then power on the DTU unit the below information is displaying on the screen 2 The HyperTerminal communication port rate should be set at 57600baud though it has been
31. l applications such as SCADA system automatic traffic control and finance etc Co working with data service center it provides a transparent data channel for customer specified applications S9910 DTU schematic block diagram is as blow M80 771001 01 4 RICON S9910 GPRS CDMA DTU User Manual Chapter 1 Introduction MDTU Bus i MPU Cascading Radio Module Main Precess Unit Interface gt Zx ZT ZN S as gt Data Bus 2 Control Bus NZ Cx aZ sZ Voice Data Power Interface Interface Management bd f User Data DC Power Speaker Microphone Interface 7 5 26V TTL RS 232 422 485 1 5 Specifications S9910 DTU s main specifications GPRS Data e GPRS Class 2 10 e Coding Scheme CS1 CS4 e Complies SMG3ibis Specifications CDMA 1x Data e Circuit switch data IS 707 A 4 Packet switch data IS 707 A 5 153kbps Class 2 0 Group 3 Fax e CDMA 2000 1XRTT e Complies IS 95A IS 95B CDMA interface Interface Antenna 500 SMA Female SIM UIM 3V Serial Port m Interface TTL RS 232 RS 422 RS 485 B Data Rate 300 115 200bits s m Terminal 3 5mm Pluggable Terminal cable 14 24AWG e Configuration RS 232 only for H7071 config cable Cascading Interface m Interface MDTU Bus Hm Connector Mini USB Voice Interface Alarm Output M80 771001 01 Earphone and Microphone TTL via 3 5mm Pluggable Terminal RICON S9910 GPRS CDMA DTU User Manual Power e Voltage
32. live interval takes effect in the TCP connection type the value sets the frequency of sending a TCP Keepalive packet which make sure the connection is still alive If the DSC can still be visited it means the packet is effective connection Keepalive and the default value is 5 minutes gt PPP Keepalive Interval At Special Setup status press 9 to enter the PPP Keepalive Interval sub menu and then the below information will be listed Follow the prompt information to set the PPP Keepalive Interval Press R to return HDOS gt 9 Current ppp keepalive Interval 0 Change ppp keepalive Interval 0 3 65535 s 10 The value sets the frequency of sending a Keepalive packet which make sure the PPP connection is still alive If the connection is still alive it means the packet is effective The default value is O no use M80 771001 01 29 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup This fuction is effective only for CDMA Products gt Display Special Setting At Special Setup status press D to display current special settings Press R to return HDOS gt D Special Setting Mobile Terminal Type 0 Call Type 1 Call Interval 60 Offline Interval 0 DSC Identity Number Communication Protocol Option None 0 DDP 1 0 Network Connection Type UDP 0 TCP 1 1 TCP Keepalive Interval 10 PPP Keepalive Interval 10 6 Set DTU Password At DTU Configuration status press 6 to chan
33. ll Type At Special Setup status press 2 to enter the Set Call Type sub menu and then the below information will be listed Follow the prompt information to set the call type The option is 0 9 Press R to return HDOS gt 2 Current Calling Type 2 Change Calling Type 0 9 1 1 Setting 0 it is valid at MTT setting 2 DTU checks its DSC IP Address setting and will send a SMS to DSC to request the DSC IP address if it is blank 2 Setting 1 itis valid at MTT setting 2 DTU checks its DSC IP Address setting and will call DSC to request the DSC IP address if it is blank 3 Setting 2 it is valid at MTT setting 2 DTU checks its DSC IP Address setting If the DSC IP address is set DTU will try to dialup mobile network and log on DSC If the DSC IP address is blank DTU is offline and waiting the DSC calling or SMS 4 Setting 3 it is valid at MTT setting 2 DTU is offline and waiting the DSC calling or SMS only The data trigger will not effect 5 Others reserved gt Set Call Interval At Special Setup status press 3 to enter the Set Call Interval sub menu and then the below information will be listed Follow the prompt information to set the call interval The options are 0 10 65535 seconds Press R to return HDOS gt 3 Current Call Interval 60 Change Call Interval 0 10 65535 s 60 Call Interval is time interval to call DSC Setting 0 is that the DTU will call DSC once only Other interval corresponds with
34. ly connected and there is no LED that light up the DTU may be failed Contact to Ricon or reseller for repairing Problem 2 NET LED does not light up NET LED will flash when the S9910 DTU logged in mobile network If the NET LED does not light up you should check the area receiving RF signal and check the SIM or UIM inserted correctly Problem 3 DATA LED does not light up DATA LED will flash when there is data transmitting over the interface Problem 4 All LED indications are normal but it can not transmit traffic data Consult with the local mobile operator to confirm it is covered with GPRS or CDMA 1x service Meanwhile check the DSC IP Address and Communication Port setting Problem 5 It is no problem to enter the management tools To enter the S9910 DTU management tools you have to create a HyperTerminal and set it properly Press and hold the PC Space key and then power on the DTU If it is still problem check the HyperTerminal setting M80 771001 01 37 S9910 GPRS CDMA DTU User Manual Chapter 4 Operation refer to the Appendix for more details Restart the created HyperTerminal hold PC Space key and re power S9910 DTU Caution The laptop PC serial port is very weak You may need to pay attention for this port and check it Furthermore the PC and DTU should be connected at same ground wire Problem 6 I have configured the DTU serial port works at 9600baud and set my PC HyperTerminal COM port rate at same rate
35. nual Chapter 2 Installation Voice Antenna SIM UIM Ground Cascading Config Attention S9910 DTU will not work and display can not find SIM UIM card if you do not insert the SIM UIM card to the end position In order to prevent this problem please put back the SIM UIM cover after you insert the SIM UIM card and screw it tight Cascading Cable Installation If the application requires a very high reliability you may cascade two S9910 DTUs One S9910 GPRS DTU and one S9910 CDMA DTU are recommended and connect the S9910 DTUs by a Mini USB cable via CONN interface You should configure the two S9910 DTUs in accordance with your system plan before putting it in service The DTU configuration procedures refer to Chapter 3 DTU Setup User Data and Power Cable Installation 9910 DTU signals and power supply is connected by industrial class pluggable terminals 3 5mm 12Pin and 14 24AWG outlet cable is recommended Each line definition refers to the following diagrams and tables Also you can find outlet cable definition table at top of S9910 DTU cover As shown in the following diagrams and tables peel off the cable end about 7mm and connect each terminal and cable 14 24AWG cable recommended Make sure that you have connected the terminals without any mistake M80 771001 01 9 S9910 GPRS CDMA DTU User Manual Chapter 2 Installation 7mm 14 24AWG Attention The power cable should
36. on will be listed Follow the prompt information to set the Identifier separator The option is 0x00 0xFF HDOS gt 9 Current Identifier Separator OxOA Change Identifier Separator 0x00 OxFF It is valid when the MTU is set to 0 At this setting DTU will transmit the traffic data by the Identifier separator If DTU detects the Identifier separator from data traffic DTU will transmit the traffic data immediately If the data traffic package length exceeds 1024 bytes and there is no Identifier separator DTU will discard the data package gt User defined Heartbeat At Data Terminal Unit DTU Setup status press a to enter the User defined Heartbeat sub menu and then the below information will be listed Follow the prompt information to set the User defined Heartbeat The option is Ox00 0x80 HDOS gt a Current heartbeat length 0x00 Change heartbeat length 0x00 OxFF 02 Change heartbeat Hex aa bb Display DTU Setting At Data Terminal Unit DTU Setup status press D to display the DTU settings M80 771001 01 20 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup HDOS gt D Data Terminal Unit DTU Setting DTU Identity Number 13812345678 Local Communication Port 50000 DTU Online Report Interval 100 DTU Maximum Transmission Unit 1000 DTU Reconnect Interval 0 Console Info Type 1 Last Packet Idle Interval 600 Identifier Separator OKOA User defined Heartbeat Len 02 Us
37. ontrol should be set to None M80 771001 01 40 S9910 GPRS CDMA DTU User Manual Appendix HyperTerminal Setting 2 Properties Start the created H7000 HyperTerminal connection Click File gt Properties menu click Settings tab set it as show as the picture H7000 Properties 3 Host System Encoding Method Click Input Translation button set host system encoding method Host System Encoding Method M80 771001 01 41 S9910 GPRS CDMA DTU User Manual Appendix HyperTerminal Setting 4 ASCII Setup Click ASCII Setup button set ASCII parameters ASCII Setup M80 771001 01 42
38. pervision automatic traffic control weather station environment protection pipe supervision finance and securities etc H7000 wireless DDN system consists of DTU H7111 GPRS DTU TTL data interface built in design H7112 GPRS DTU RS 232 422 485 data interface H7118 GPRS DTU RS 232 422 485 data interface high performance H7161 GPRS DTU Ethernet interface H7611 CDMA DTU TTL data interface H7612 CDMA DTU RS 232 422 485 data interface H7661 CDMA DTU Ethernet interface S9910 GPRS CDMA 1x DTU RS 232 422 485 data interface platform designed with customer specified options Data Service Center e H7030 wireless DDN data service center development pack it provides classes functions packages and ActiveX controls Meanwhile Virtual Serial Port Divers can be provided for existing system s selections e H7036 wireless DDN data service center router it transfers the user data and converts the transmission protocol it can be connected with the broadband network access and the GPRS CDMA 1x network to transmit and convert the data from to GPRS CDMA DTU and then transmit the data to user application data service center Typical center to multipoint system configuration plan is as below M80 771001 01 2 RICON S9910 GPRS CDMA DTU User Manual Chapter 1 Introduction User Data Service Center Integrated with User s Application gt 9910 DTU RS232 User Device s
39. pose Input 5 OFF Power Off Control 6 GPO General Purpose Output 7 R Receive Data Only RS 422 8 R Receive Data Only RS 422 9 RING Ring Signal 10 GND Ground 11 GND Ground 12 Vin 7 5 26V DC Input Current 350mMA 12V M80 771001 01 11 S9910 GPRS CDMA DTU User Manual Chapter 2 Installation Voice Cable Connection Open SIM UIM card protection cover on top PIN1 EAR of S9910 you will see a 4PIN connector TI TF Fa PIN2 MIC from left to right itis PIN1 PIN4 for signal PIN3 MIC of earphone amp microphone PIN4 EAR 2 4 Grounding To ensure a safe stable and reliable S9910 DTU operation DTU cabinet should be grounded properly Connect the S9910 DTU cabinet to site ground wire at the ground point refer to page 9 picture 2 5 Power Supply 9910 DTU is designed with advanced power management technologies it can operate standalone The DC power is supplied via pluggable terminal Pin 11 GND and Pin 12 Vin Detail definitions refer to above tables About Power Supply When S9910 GPRS DTU communicates with base station surge current will exceed normal current Therefore margins 5 times over normal current may be required for external power supply Normally S9910 DTU input power supply is 7 5 26VDC in most cases 12VDC 1A is recommended Power input of 5VDC can be ordered for specified application Power supply ripple should be less 300 mV 2 6 Check the Mobil
40. rd AA KAA KAA KKK gt Access Point Name At Mobile Service Center MSC status press 4 to enter the Access Point Name sub menu and then the below information will be listed Follow the prompt information to change the access point name If the access point name is less than 24 characters press Enter key to confirm HDOS gt 4 Current Access Point Name CMNET Change Access Point Name shenzhen0123456789012345 Setting Access Point Name Please waiting Above parameters should be set in accordance with the information provided by the local mobile network operator Consult with the local mobile network operator for details gt SIM UIM PIN At Mobile Service Center MSC status press 5 to enter the SIM UIM PIN sub menu and then the below information will be listed Follow the prompt information to change the SIM UIM PIN If the SIM UIM PIN is less than 8 characters press Enter key to confirm Leave it in blank to delete the SIM UIM PIN setting HDOS gt 5 Input New SIM UIM PIN Confirm New SIM UIM PIN M80 771001 01 16 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup gt Display MSC Setting At Mobile Service Center MSC status press D to display MSC settings HDOS gt D Mobile Service Center MSC Setting Service Code 99 1 PPP Username 012345678901234567890123456789 Access Point Name shenzhen0123456789012345 2 Data Terminal Unit DTU Setup At DTU
41. rt Setup status press 4 to enter the Stop Bits sub menu and then the below information will be listed Follow the prompt information to set the stop bits HDOS gt 4 Current Stop Bit 1 Change Stop Bit 1 2 1 gt Flow Control At Serial Port Setup status press 5 to enter the Flow Control sub menu and then the below information will be listed Follow the prompt information and select a correct option to set the type of Flow Control HDOS gt 5 Xon Xoff Hardware None Half Duplex RS485 Full Duplex RS422 Return Notice The options 1 2 and 3 are suitable for S9910C or S9910D the options 4 and 5 are suitable for S9910S or S9910F Display Serial Port Setting M80 771001 01 25 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup At Serial Port Setup status press D to display the Serial Port setting HDOS gt D Serial Port Setting Baud Rate 57600 Data Bits 8 Stop Bit 1 Parity Bit None Flow Control None 5 Special Setup At DTU Configuration status press 5 to list the Special Setup sub menu HDOS gt 5 Special Setup Mobile Terminal Type Set Call Type Set Call Interval Set Offline Interval DSC Identity Number Communication Protocol Option None 0 DDP 1 Network Connection Type UDP O TCP 1 TCP Keepalive Interval PPP Keepalive Interval Return a O QO I O I Q N The Special Setup is designed for the dynamic IP address data service center there ar
42. s used at the DTU the DNS IP Address must be configured and the DNS should work stable Otherwise it will affect the radio link reliability and cause a very big traffic gt Backup DSC IP Address At Data Service Center DSC Setup status press 5 to enter the Backup DSC IP Address sub menu and then the below information will be listed Follow the prompt information to set an Backup DNS IP Address HDOS gt 5 Current DNS IP Address Change DNS IP Address The default back up DNS is 0 0 0 0 When the main channel is unusual or unreasonable failed the system will automatically switch to prepare to set the back up channel for communication and eventually play a backup channel 1 1 gt Backup DSC Communication Port At Data Service Center DSC Setup status press 6 to enter the Backup DSC Communication Port sub menu and then the below information will be listed Follow the prompt information to set an Backup DSC Communication Port HDOS gt 6 Current Port Value 5006 Change Port Value 5005 Back up the DSC server communications port Specific port number is allocated in the light of your system design with the same functioning of the main DSC PORT gt Display DSC Setting At Data Service Center DSC Setup status press D to display the DSC current settings M80 771001 01 23 S9910 GPRS CDMA DTU User Manual Chapter 3 DTU Setup HDOS gt D Data Service Center DSC Setting DSC IP Address 210 21 197 10
43. telecom service providers are required to provide industrial application solutions not only meeting common specifications and also individual special ones Hence we must co operate with mobile service providers to design products and network configurations suitable to industrial end users individualized applications we must develop specified data terminal unit data service center software and network configuration for the applications M80 771001 01 1 RICON S9910 GPRS CDMA DTU User Manual Chapter 1 Introduction Based on years of experience of providing mobile data s industrial application solutions and service operator s network configurations Ricon Technologies has designed S9910 DTU which works at an advanced platform with individualized feature options to meet different requirements GPRS network theoretically can provide a maximum bandwidth 171 2Kbps actually it works at 40 100Kbps bandwidth it depends on service provider s operation policy As we know GPRS is packet based network which provides TCP IP communication channel Same as GPRS network CDMA 1x network can provide a maximum bandwidth up to 300Kb s and actual transmitting and receiving bandwidth reaches 100Kb s Ricon Technologies has developed H7000 wireless DDN system which provides industrial end user a virtual private data network of high speed always online and transparent data transmission It can be widely used at area power SCADA system industrial su
44. urations and commissioning Then we can disconnect the testing cable and connect DTU with the user data device M80 771001 01 35 S9910 GPRS CDMA DTU User Manual Chapter 4 Operation Chapter4 Operation This chapter habas the 9910 GPRS CDMA DTU operation guidance and relative information 1 Panel Indications 2 DTU Operation Guidance 3 Trouble Shooting 4 1 Panel Indications There are three LEDs at S9910 DTU front panel it indicates the DTU and network operation status LED Statues Description PWR Lights up Running management program Flash Fast Unable attach to GPRS CDMA network Flash Slow Attached to GPRS CDMA network DATA Flash Data interface traffic indication NET Lights up Found GPRS CDMA network NET LED is different with modules Module Type NET LED Description A AnyData Flash Attached to GPRS CDMA network B BenQ Flash Attached to GPRS CDMA network E Sony Flash Attached to GPRS CDMA network Ericsson Flash Attached to GPRS CDMA network H Huawei Flash Attached to GPRS CDMA network M Motorola Lights up Attached to GPRS CDMA network S Siemens Flash Attached to GPRS CDMA network Z ZTE Flash Attached to GPRS CDMA network W Wavecom Flash Attached to GPRS CDMA network 4 2 DTU Operation Guidance S9910 DTU is an intelligent data terminal it will operate itself to provide a reliable transparent data communication channel Meanwhile user

Download Pdf Manuals