Home

User Manual For CP4 - Busparts

image

Contents

1. Example When it is live view or menu interface the screen will turn to the main interface after drivers press Broadcast Again d When drivers press Broadcast the speaker will broadcast the next bus station information inside and outside of the vehicle User Manual for CP4 Example If the speaker says we are arriving XX and it will turn to we are leaving XX when pressing Next Stop e Press Enter to view system information and open the selected menu f Press Exit to exit current interface and switch from the main interface to the live view interface g Press KI to go left exit the current status switch the module or interrupt the outside calling h Press E and M to go up or down i Press IB to go right or stop the current broadcast 1 3 3 Product Specification mems Parmetor Performance ndx Panel Material 70 PC 30 ABS Engineering plastics Material Button Material RFID Wipe Card Module 13 56 MHZ for driver to sign in and sign off Built in Module Speaker 100 2W x2 MDVR Interface Connects to Streamax MDVR Yellow 4PIN aviation din connector connects CAM Interface to reversing camera Interface MIC Interface Connects to the driver microphone Yellow hanging line reversing signal detection port high level effective To monitor SENSOR Interface control for reversing Restate station announcer Arrow Keys Function Buttons Confirmation Exit Button 0 Performance Relative Humidity 8906 9096
2. Keep 40 C 2 C for 1 hour Keep 85 C 2C for 2 hours Keep 85 C 2C for 1 hour Keep 23 C 5 C for 2 hours Test eguipment applies to GB T 2423 3 2006 Keep for 24hours at 40 C 2 C 90 95 non condensing without power supply User Manual for CP4 2 2 Mechanical Environmental Performance Serial No Experiment Items Test methods Impact H a Crash Test equipment and method apply to GB T 2423 5 2008 Normal installation and without power supply the peak acceleration is 490 m s and pulse duration is 11 ms Six sides do these steps 3 times Test equipment and method apply to GB T 2423 10 2008 Normal installation and without power supply the vibration frequency is 5 Hz 300 Hz and scanning speed is 1 otc min In 5 Hz 11 Hz frequency range the amplitude is 10 mm In 11 Hz 300 Hz frequency range the vibration acceleration is 50 m s On X Y Z three mutually perpendicular axis each axial does it for 8 hours Test equipment and method apply to GB T 2423 6 1995 Without power supply and any external protections Peak acceleration is 150 m s rated pulse duration is 6 ms Per direction collision is100 5 times Test equipment and methods apply to GB T 2423 8 1995 Without power supply and any external protections it falls from 500 mm height
3. Parameters User Manual for CP4 1 3 4 LCD Specification Screen Tye i uos Touche awreressorwP Se mmm SPSS Resoun OBS EE O Under a suitable brightness condition the higher contrast the Contrast Ratio 20 83402778 richer color levels The response time of the LCD to 70 70 50 70 Typ CR dot Visual Angle 10 Left Right Up Down Maximum Number of Display 262K 16 7M 6bit 6bit Dithe Sae O Y t I 1 3 5 Bracket Installation CP4 supports bracket installation and there are three brackets to be chosen Suitable for relatively flat console Suitable for curved console Suitable for hanging User Manual for CP4 1 3 6 Interface To ensure the waterproof the external interface of CP4 uses harness which leads a bunch of buses from CP4 and then the joint distributes according to their functions details are as following 10Pin aviation din male _ WIZ ANP i 4Pin aviation din male Yellow Big 5559 4Pin male Black apo injection Ee Yellow UL1007 20AWG Definition Connector Name Funcion Definiton ps bL oy g i e Laya 2 1 12V 24AWG Black 10PIN aviation din male connector A sm zu i has 4 RXD connects to Streamax MDVR cr A DTOS 3 6 AUDIO 7 MDVR O an 1 GND 2 MIC 3 MIC 4 MIC SW_IN 1 Power 2 GND Yellow 4PIN aviation din connector Z 3 Audio signal 4 Vido signal CAM connects to reversing camera O4 Vido sig 3 i Connects to driver microph
4. information will be uploaded to platform via MDVR network 1 2 6 SMS and Voice Broadcast Built in 2 speakers 160O 2w they are used to broadcast messages and some prompts 1 2 7 Intercom Connect with microphone and MDVR it can realize the functions of speaking inside outside of the vehicle IP connection and making calls User Manual for CP4 1 3Product structure 1 3 1 Product appearance and size Dimension of CP4 1 3 2 Button Introduction CP4 applies with 18 buttons including 1 0 number buttons 4 function buttons and 4 arrow buttons for bus control and scheduling application a When drivers press number 1 5 it broadcasts the messages set before and if there is no message it would not broadcast anything Supported only with firmware of bus station announcer version Example When drivers press 1 it broadcasts Please take care of your belongings b When drivers press number 6 0 it sends message set before and if there is no message it does not send anything Example When drivers press 9 it will send a message to reguest schedule If it is done successfully the center will send a conformed message back and the bus station announcer will broadcasts it automatically c When drivers press Broadcast Again the speaker will broadcast the the message again or switch the inside calling to outside calling or interrupt outside calling
5. User Manual for CP4 4 dj _ 7 a i 7 a was A a r Bica User Manual For CP4 User Manual for CP4 1 Product Characteristic 1 1 Overview CP4 is a control panel used for bus intelligent dispatch system Adopted with 18 buttons 7 inches large screen display it also integrates with features of SMS reversing monitor and driver swipe card etc It is widely applied to domestic and overseas bus systems for its easy installation powerful features and convenient operation 1 2Features 1 2 1 Control Panel CP4 controls MDVR via RS232 serial port and driver can setup MDVR on CP4 The function of CP4 is similar to remote control Besides it also can setup the menu of CP4 1 2 2 Bus Station Announcer It works with MDVR supported only with firmware of bus station announcer version to announce the stations manually automatically 1 2 3 Live View Menu and video can be transmitted to CP4 via pass through mode CP4 can setup the other functions of MDVR such as record and playback 1 2 4 Reversing Live View There is an AV aviation din on CP4 drivers can connect the camera with CP4 It is not used for recording or monitoring but to view the reversing vehicle and other live view Besides there is a sensor using to connect with NO signal which is to switch the pictures of camera 1 2 5 Drivers Swipe Card There is a built in RFID module in CP4 which is used for drivers to sign in and sign out The
6. one MIC Yellow hanging line reversing signal Hanging line detection port high level effective For SENSOR SENSOR reversing control User Manual for CP4 2 Product Performance 2 1 Environmental Performance Serial No Experiment ltems Test Methods Low Temperature Operation Low Temperature Storage High Temperature Operation o High Temperature Storage Temperature Shock Steady Damp Heat Test equipment applies to GB T 2423 1 2008 Put into the cryogenic chamber at 20 C 2C for 72 hours at 0 85 times rated voltage During this time cut off the power for 1 hour and reconnect the power for 1 hour repeatedly until the end of the test Test equipment applies to GB T 2423 1 2008 Put into the cryogenic chamber at 40 C 2 Cfor 8 hours without power supply Recover to normal temperature after the test Test eguipment applies to GB T 2423 2 2008 Put into the high temperature chamber at 70 C 2 C for 72 hours at 1 25 times rated voltage During this time cut off the power for 1 hour and reconnect the power for 1 hour repeatedly until the end of the test Test eguipment applies to GB T 2423 2 2008 Put into the high temperature chamber at 85 C 2 C for 8 hours without power supply Recover to normal temperature after the test Test eguipment applies to GB T 2423 1 2008 and GB T 2423 2 2008 Test cycles with the following procedures without power supply for 24 hours Keep 40 C 2 C for 2 hours

Download Pdf Manuals

image

Related Search

Related Contents

(全24ページ)(PDF:5.2MB)  FT-VINIFLCH11.FR rev.0  県立図書館8月の新着図書紹介  Melissa 653-114 User's Manual  その他  HWW 900 GC - Website for Güde  Kapitel 2 Das 3D-Modell  Programme Habitat durable - association lorraine énergies  

Copyright © All rights reserved.
Failed to retrieve file