Home

Manual USA OK.cdr - Farmers Market Scales

image

Contents

1. 3 14 IERSE PLU s direct access keys 9 Key used to turn on off the backlight IMPORTANT WARNINGS Sa A 2 Do not open the scale on 3 Never press the keyboard your own your warranty will with objects such as pencils be canceled pens knives etc 1 In case you have a problem with the scale first read the the warranty conditions 4 use a 220 v ac outlet exclusive for the scale avoiding overload or voltage variations 5 never wash the scale using a flow of water this can damage the electronic components for more information read maintenance and cleaning section 6 protect the scale from insects 7 do not drop or hit the scale 8 do not use solvents or mainly from roaches they can seriously with the product to be weighted detergents for cleaning damage the electronic components Use because as time goes by it will only use a damp rag solid products against roaches damage the weight sensor 9 do not place fans or heaters 10 do not place the scale where 11 only authorized and qualified directed towards the scale there is a lot of moisture and or personnel should check and dust repair your scale GENERAL VIEW FINDER LCD DISPLAY 9 8 4 gogog je gt 58886 888888 2 UPPER LEFT indicator shows the products weight in POUNDS or KILOGRAMS when this happens the symbol Ib or kg appears in the alphanumeric MODE indicator PRICE ind
2. DC power supply to make sure the ends are in good condition and that the cable is not twisted or tangled Regularly check the scale to assure it is correctly leveled with its four bases well supported When you clean the scale make sure that there are not any papers or any other kind of material under the plate or under the plate holder that could obstruct the adequate operation of your scale Periodically place some type of insecticide on the scales base to avoid insects specialy roaches that can dirty the interior and alter its adequate operation Do not use detergents nor corrosive liquids while cleaning Do not expose your scale to temperatures below 10 C 14 F or above 40 C 104 F TROUBLESHOOTING Before you call for service to your authorized distributor because of a malfunction in your scale we suggest you first check this manual again to avoid a misunderstanding of the operation and use of the functions If everything is correct then try to correct the problem according to the following list since a simple checkup or a small adjustment could eliminate it If you do not find the problem contact your authorized distributor POWER OFF TIMER FUNCTION This function is permanently enabled when the scale is on and only when you do not have the AC DC power supply connected to the scale When the scale is not use for a period of time greater then 15 minutes it will automaticaly turn off and therefore all the infor
3. necessary to recharge the battery Even with this signal it is possible for the scale to keep on operating for a short period of time 30 minutes but after a second warning signal appears LO bAt fix in the display the scale stops itself and does not respond to the instructions until the battery be recharged or be connected to the AC main iol E It does not operate There is not electric current With a multimeter check if there is electric current in the outlets AC DC Power supply cable Check that the AC DC power supply has a false contact terminals if it is possible check with another AC DC power supply Connect the AC DC power supply if the scale operates then recharge the battery Low battery The scale shows different Material under the plate Check that there are not materials weights when the same holder is obstructing the under the plate holder If there are product is weighed several correct movement remove them and check the times operation again The scale was turned on Remove the weight or put back the If the message PLS with a weight on the plate or plate in its place Turn off the scale UnLOAD appears in the without the plate and then turn it on again view finder The word HELP appears The scale was turned on Remove the weight and turn off the in the PRICE indicator with a big weight on the scale and then turn it on again TECHNICAL SPECIFICATIONS 40 lb 40 Ib 999 99 Range of oper
4. suggest to have at hand the product list that are saved in each memory address To delete all the memories that are stored turn the scale on and during the countdown type foy D and all the memories will be deleted to zero HOW TO TURN ON THE BACKLIGHT This scale model has a backlight that helps you to see better the display information It can be turned on in two ways 1 Automatically when an AC adaptor is connected to the scale 2 Manually It can be performed by pressing the ey key And can be turned off in two ways 1 Automatically when the scale is powered only by battery and the battery is low the backlight is turned off 2 Manually It can be performed by pressing the ey key Note Using the backlight and only powering the scale with the battery the charge of the battery will last less hours This arrow indicates that the scale is working under the FIXED PRICE mode 0 00 H 100 00 0 This arrow indicates that the scale AC adaptor is connected to the 120 VCA MAINTENANCE AND CLEANING Do not use a flow of water to clean your scale Use a damp rag and clean each of these components daily plate cover keyboard To remove oil and greasy substances use a dry and clean rag rubbing the dirty area several times Periodically check the jack where the AC DC power supply is inserted to make sure it is in good condition That is there are no signs of strokes or detachments Periodically check the AC
5. Even with this advise the scale can continue working during a time of 30 min If it appears and after some seconds the scale turns off it indicates that the scale is completely discharged In this point the scale doesn t work and all of the operations performed at that time will be lost To correct this problem connect the AC DC adaptor for a period of time of 10 hrs and keeping the scale off In case of using the scale during this period there s no problem to use it only the recharge time will be higher HOW TO LOAD A MEMORY 1 Press the key fey and then the memory address 00 99 you wish to load or just press any of the direct access keys eo Example If you wish to save 26 60 in the memory address 6 follow these steps 1 Type 2 Press sro 3 Type or just press the direct access key With this sequence the price is saved in the memory address 06 If you wish to load the memory of this example just type or just i and in the PRICE indicator will be displayed the price stored in memory in this case will be 26 60 To change the price stored in a memory just type the new price and store it in the memory address you want to change following the procedure described above These keys are very useful to avoid type the same price constantly To use these memories we
6. FABRICANTES DE BASCULAS TORREY S A DE C V ELECTRONIC SCALE L PC seris USA USER S MANUAL REVISION 1 1 IMPORTANT BEFORE OPERATING THIS SCALE PLEASE READ THIS MANUAL THROUGLY NAME AND LOCATION OF IMPORTANT PARTS CABINET Manufactured in stainless steel and resistant to corrosion and strokes PLATE Also manufactured in stainless steel with the border bent and rounded PLATE HOLDER Manufactured in aluminum that provides resistance to corrosion LEVEL BUBBLE Inserted in the cabinet It is used to level the scale MEMBRANE KEYBOARD It has multifunctions with big and readable keys GENERAL VIEW FINDER It shows the necessary information it has individual indicators upper left indicator alphanumeric MODE indicator PRICE indicator TOTAL indicator LEVELING BASES They level the scale tightening or loosening them JACK Connects the AC DC power supply to the scale 9 CUSTOMER VIEW FINDER Customer display IMPORTANT WARNINGS INTRODUCTION INSTRUCTIONS FOR INSTALLATION NAME AND LOCATION OF IMPORTANT PARTS KEYBOARD GENERAL VIEW FINDER LCD DISPLAY OPERATIONS DESCRIPTION HOW TO WEIGHT A PRODUCT HOW TO ENTER PRICES HOW TO CLEAR WRONG PRICES USE OF THE FIXED PRICE USE OF THE TARE HOW TO USE THE REFERENCE TO ZERO PRICE ADD UP PRICE MULTIPLING FUNCTION HOW TO SAVE MEMORIES HOW TO LOAD A MEMORY HOW TO TURN ON THE BACKLIGHT POWER
7. OFF TIMER FUNCTION USE OF THE BATTERY BATTERY RECHARGE LIFE TIME OF THE RECHARGEABLE BATTERY LOW BATTERY INDICATOR HOW TO ACCESS DE COUNTERS OTHER IMPORTANT MESSAGES THAT APPEAR ON THE SCALE MAINTENANCE AND CLEANING TROUBLESHOOTING TECHNICAL SPECIFICATIONS OOO ONNNNDDDOTBR WWD WARNING IIDO NOT OPEN jj RISK OF SHORT CIRCUIT CAUTION TO REDUCE THE RISK OF SHORT CIRCUIT IN YOUR SCALE DO NOT REMOVE THE COVER OR SUBSTITUTE ANY OF THE PARTS FOR OTHERS THAT ARE NOT ORIGINAL ONLY AUTHORIZED DISTRIBUTOR KEYBOARD Cle ee Lisi O TAa cog 1 on Key used to turn on the scale 2 G When this key is pressed the appliance turns off This key is used to eliminate any containers weight that you do not wish to consider ring a transaction for example boxes bags bottles etc 3 This key is used to start with zero on the weight u 4 d 5 It is used to store prices in a memory location of the scale 6 fe It is used to load a PLU price from memory 7 Key used to add prices up 8 ees Numerical section it is useful to enter data into the scale such as price per pound or kilogram 9 00 Enter two zeroes 10 c Key used to clear wrong data that has been entered with the keyboard It is also used to eliminate the FIXED PRICE function 11 It enables the function FIXED PRICE 12 Keys used to multiply the unit price under 1 2 o 1 4 Ib or kg mode
8. SAVE MEMORIES Your scale has 100 memories to store the prices of 100 products that are sold more frequently The memories are numbered from 00 to 99 To save a price in a memory location 1 Type the price you wish to save 2 Press key 3 Type the memory address 00 99 in wich you wish to save the price or you also can press any of the direct access keys ee com a When the scale is turned on with an excessive weight on the plate near to the half capacity of the scale To correct this situation remove the weight on the scale turn off the scale and then turn it on again b When the scale was handled roughly and or got hitted during the shipment wich caused irreversible damages in its operation In this case call your authorized distributor This message indicates a negative weight this could happen if you lift or remove the scales plate to correct this put the plate back in its place and press the key or turn the scale off and then turn it on again PLS UnLOAd This message appears when If we turn on the scale with a product on the plate to eliminate this message simply remove the product that is on the scale turn off the scale and then turn it on again This message indicates that the total was exceeded when the multiplication price per weight exceed 999999 then appear lines in the TOTAL indicator LO BAt If this message appears in intervals on the display indicates that the scale needs to be recharged
9. ation temp 14 to 104 F 10 to 40 C Range of storage temp 4 to 122 F 20 to 50 C AC DC POWER SUPPLY OUTPUT 9 Vd c 500 mA APPROVED BY
10. es you should use this function and to eliminate it just remove the container from the plate and press key again As in the tare function this function is also substractive from the scale capacity for example if you reference to 10 Ib the scale will only be able to weight up to 30 Ib Due to voltage variance or some other factor it is posibble that without having any weight over the plate the view finder shows some weight or that the zero flag it s not on then press the key and the scale will be referenced to zero turning the zero flag on HOW TO ACCESS THE COUNTERS The scale is equipped with two important counters The Calibration counter and the counter of times that configuration has been changed This counters must be only accesed by oficial office of weights and measures inspectors The calibration counter displays the number of times the scale has been recalibrated by a technician The counter of times that the internal configuration has been changed displays the number of times that a technician has reconfigured the internal function in the scale In both cases the customer can only check the amount that is displayed but can not make any changes To check the counter follow these instructions A Calibration counter 1 Turn on the scale 2 Press lc during the initial countdown at the end of the countdown the view finder will display B Counter of times that the internal co
11. icator shows the price per POUND or KILOGRAM of the product This price can have up to 5 digits ALPHANUMERIC MODE indicator this can show the following readings When a product is being weighed on the scale When there is a negative weight l When you want to see the total sale Total amount to pay indicator TOTAL shows the partial or total sale during a commercial transaction ZERO indicator this reference to ZERO indicates that the scale is ready to start weighing products The indicators disappear when a weight is placed on the scale NET indicator indicates that the TARE function has been activated This indicator disappears when you press the key FIXED PRICE indicator when it is activated it indicates that the price per POUND or KILOGRAM that is shown in the indicator will not be cleared automatically when the product is removed from the scale it is fixed LOW BATTERY indicator when the battery energy is too low this indicator turns on to tell you that it is necessary to recharge it AC DC POWER SUPPLY indicator it means that the scale was connected to the AC DC power supply OPERATIONS DESCRIPTION HOW TO WEIGHT A PRODUCT At the end of this countdown sequence zeroes will appear in the view finder indicating that the scale is ready to use If not see section reference to zero Then place the product to be weighed on the plate and you will see the weight in the corresponding i
12. ice follow these steps 1 Place the product on the plate 2 Enter the product price per pound or kilogram 3 Press After these steps a small arrow will light up in the upper right corner of the TOTAL indicator pointing to the label P PACK fixed price As an example suppose that the product is ham the weight is 4 pounds and the price is 2 70 per pound after entering the fixed price the view finder will look like this To clear the fixed price function just press the c USE OF THE TARE When you wish to weight a product in a container but you do not want to consider the containers weight during the operation you can use the TARE function To use this function follow this steps 3 Remove the container and put the sugar inside it When you remove the container a negative number weight of the container appears in the UPPER LEFT indicator 4 Place the container on the scale and put in the container sugar until you have 15 Ib Then enter the price per pound press It is important to mention that this function is substractive from the scale maximum capacity For example if you have a container that weights 7 lb The scale will only be able to weight up to 33 Ib of product to complete the maximum capacity HOW TO USE THE REFERENCE TO ZERO This function has two uses a Permanent tare when you wish to weigh some products over a same container several tim
13. mation of the transaction you were doing will be lost To turn on the scale again just press the key and repeat your customers operations The power off timer function permits you to save electricity and avoids constant battery recharges USE OF THE BATTERY As mentioned before the scale can operate with a 6 volt built in battery or with an AC DC power supply The battery is rechargeable using the AC DC power supply BATTERY RECHARGE To make this operation just connect the AC DC power supply to the scale for 10 HOURS making sure that the scale was turned off When you recharge the battery for some hours but the battery can not get enough charge to turn on the scale then you must have to charge the battery in this case contact to your authorized distributor LIFE TIME OF THE RECHARGEABLE BATTERY SERVICE LIFE IN RELATION TO CHARGE DISCHARGE CYCLES OF CAPACITY AVAILABLE CHARGE AND DISCHARGE CYCLES The charging capacity of the rechargeable battery in this scale decreases according to the number of charge discharge cycles this causes that the service life is reduced to 1000 cycles For these reason the warranty period for the battery is limited to six months after the purchase date of the scale LOW BATTERY INDICATOR If the battery does not have enough energy to keep the scale operating a long time a low battery message will appear flicking in the PRICE indicator LO bAt This is the first warning signal indicating that it is
14. ndicator INTRODUCTION DEAR CUSTOMER We appreciate that you have chosen this product and we assure that you will get the maximum satisfaction of the new acquisition for your bussines The scale has been designed to give you a great deal saving time and money avoiding losses by human mistakes of interpretation and calculation offering you more fluency and security in your commercial tasks To make your equipment a long lasting investment we suggest to read carefully this manual and make sure to keep it at hand for later consultations In this manual we indicate the necessary steps to benefit and prolong your appliances availability INSTRUCTIONS FOR INSTALLATION 1 Unpack the scale and check the conditions of the product If it is damaged report it inmediately to your authorized distributor 2 Place the scale where there is not any movement or vibration make sure it is leveled adequately checking that the four leveling bases are supporting the scale over the surface were it has been placed and if the level bubble under the plate is centered to adjust tighten or loosen the leveling bases until the bubble is in the center of the circle 3 Connect the AC DC power supply if you use it to 220 V A C outlet 4 Turn the scale on after the countdown sequence your ee scale will display zeroes and will be ready to use I READY IMPORTANT NOTE If your scale displays HELP after you followed the previous steps and after the ini
15. nfiguration has been changed 1 Turn on the scale 2 Press 6 K countdown the view finder will display during the initial countdown at the end of the If any of the two cases to get to the normal operation mode just turn off the scale and turn it on again Your scale leaves the factory like the examples OTHER IMPORTANT MESSAGES THAT APPEAR ON THE SCALE OLOAD 7 This message indicates that a weight that exceeds the maximum capacity has been placed on the scale To correct it simply remove the over weight PRICE ADD UP When you want to add some prices up follow these steps 1 Put the commodity over the plate 2 Remove the commodity with the unit price for example a price of 2 20 and a weight of 1 50 Ib and press r 4 When you press e with 3 Put another good with the unit the total indicator in zeroes you will see the sum total accumulator without adding any price up price and then press l TOT 2 6 50 5 To delete the sum total press a key when the sum total is PRICE MULTIPLING FUNCTION When you want to use the price per 1 4 or 1 2 Ib or kg put the weight over the plate and enter price per 1 4 or 1 2 Then press or key automatically appears the price per Ib or kilogram If the price does not exceed 999 99 It will be displayed on the unit price If you want to use any of these keys again remove the commodity and follow the same procedure HOW TO
16. tial countdown it means that it was handled roughly and or got hit during the shipment wich cause irreversible damage in its operation Call your authorized distributor Is possible that the scale displays HELP when you turn it on with weight on the plate when this happens remove the weight and turn the scale off and then turn it on HOW TO ENTER PRICES The product price per pound or kilogram is entered pressing the numbers of the keyboard to indicate the desired value This value will appear in the PRICE indicator and the total amount to pay will be calculated automatically being shown in the TOTAL indicator For example if the product price per pound in the previous examples is 8 20 just press and the following display will appear J 8 20 209 10 HOW TO CLEAR WRONG PRICES When a mistaken price is entered you can clear it in two ways a Manually Simply press the clear C key and enter the correct price b Automatically The price is automatically cleared removing the product from the plate except if it s not enabled the fixed price function FIXED PRICE FUNCTION When it is necessary to constantly be weighing the same kind of product one does not change its price you can use the FIXED PRICE function It is used to keep the price FIXED in the PRICE indicator avoiding it to be automatically cleared when the weight is removed from the scale To fix a pr