1. Model Suffix Code Descriptions YTMX580 Multi Input Temperature Transmitter Output Signal L Wireless communication ISA100 11a Housing 7 Always 7 0 G 1 2 female nine electrical connections Electrical Connection 2 1 2 NPT female nine electrical connections 4 M20 female nine electrical connections Integral Indicator N None L 316 SST 2 inch pipe mounting Mounting Bracket WwW 316 SST wall mounting N None Power Supply A Battery case only battery not included with a blind plug Antenna 5 A Integral antenna B Remote antenna 6 Temperature Unit A Cel K 2 B Cel K degF degR 3 A Always A Option Codes Optional specifications See Option Code 1 For wall mounting please prepare bolts and nuts 2 This is a Japan only specification only available to end users inside Japan 3 In Japan degF F and degR R are non statutory measurement units Suffix code B can only be specified by end users outside of Japan 4 Order the remote antenna cables separately from accessary option 5 Use of antenna is limited by local regulation of radio and telecommunication law Consult Yokogawa for details 6 Not selectable for TIIS explosion proof specifications suffix code JS37 Note Cel means C degF means F and degR means R m OPTIONAL SPECIFICATION Item Description Option Code Coating High anti cor
2. Degrees of Protection IP66 IP67 NEMA Type 4X Connection Terminal 4 mm Screw terminal Name Plate and Tag 316 SST Mounting Blacket 316 SST Select pipe mounting or wall mounting Weight 3 2 kg 7 05 Ib Without mounting bracket Connections Refer to MODEL AND SUFFIX CODES m ACCESSORIES Remote Antenna Cable optional accessories Only by order of option Specification of Cable 83D SFA HDPE Outside Diameter of Cable 11 1 mm Minimum Bend Radius 67 mm when fixing 167 mm when wiring Cable End Treatment N type connector one end is male and the other is female Operational temperature range 40 to 85 C 40 to 185 F When fixing shows the bending radius for fixing the state is maintained for a long time When wiring shows the bending radius while checking the wiring position This bending radius is set larger than that for fixing in order to prevent damage to the cable because the cable is likely to be repeatedly bent when checking the final wiring position GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt Table 1 Sensor type measurement range and accuracy Sensor Type Standard Measurement Range Accuracy 100 to 1820 C 212 0 to 3308 0 F Accuracy not guaranteed for less than 400 C 752 0 F 2 54 C 4 57 F in the range from B 400 C
3. 40 to 85 C With remote antenna mounting bracket F9193UB Antenna cable 3 m Operational temperature range 40 to 85 C With remote antenna mounting bracket F9193UC Antenna cable 4 m 1 m 3 m with arrestor Operational temperature range 40 to 85 C With remote antenna mounting bracket F9193UD Antenna cable 6 m 3 m 3 m with arrestor Operational temperature range 40 to 85 C With remote antenna mounting bracket F9193UE Antenna cable 13 m 3 m 10 m with arrestor Operational temperature range 40 to 85 C With remote antenna mounting bracket Antenna F9193DH 2dBi Remote Antenna White 1 Use of remote antenna cable is limited by local regulation of radio and telecommunication law Consult Yokogawa for details Product Model code part number Specification Battery pack assembly F9915NQ t Battery case Lithium thionyl chloride batteries 2 pieces Battery case F9915NK 2 Battery case only Batteries F9915NR Lithium thionyl chloride batteries 2 pieces B8808DE Front door Gasket 1 piece Front door part B8808DM Front door Bolt Cap Long 1 piece B8808DN Front door Bolt Cap Short 1 piece B8808EM Front door Bolt SUS316 1 piece Bracket B8808DW 2B Pipe Mounting Bracket SUS316 B8808DV Wall Mounting Bracket SUS316 Shunt resistor X010 050 1 50 Q 0 1 for 4mm screw terminals Operational temperature range 25 to 80 C 1 Ifyou need F9915MA pl ease purchase F9915NQ F9915NQ is a set of F9915MA
4. Management Station YFGW410 Refer to GS 01W02D01 01EN Field Wireless Access Point YFGW510 Refer to GS 01W02E01 01EN Field Wireless Media Converter YFGW610 Refer to GS 01W02D02 01EN Versatile Device Management Wizard FieldMate Refer to GS 01RO1A01 01E Thermocouple Refer to GS 06B01B01 00E GS 06B01E01 00E Mineral Insulated Thermocouple Refer to GS 06B02D01 00E Resistance Temperature Sensor Refer to GS 06B03B01 00E GS 06B04D01 00E Protection Tube Thermowell Refer to GS 06B02T02 00E Paperless Recorder DAQSTATION DX1000 DX2000 Refer to GS 04L41B01 01E GS 04L42B01 01E Data Acquisition Unit MW100 Refer to GS 04M10A01 01E lt Related Documents gt Field Wireless System Overview Refer to GS 01W01A01 01EN lt Trademarks gt All the brand names or product names of Yokogawa Electric used in this document are either trademarks or registered trademarks of Yokogawa Electric Corporation Company and product names used in this manual are trademarks or registered trademarks of their respective holders The company and product names used in this manual are not accompanied by the trademark or registered trademark symbols and GS 04R01B01 01EN Feb 27 2014 00
5. less than 400 C 752 0 F 0 64 C 1 15 F in the range from RTD Pt200 IEC751 400 C 752 0 F or more to less than 500 C 932 0 F 0 74 C 4 1 33 F for 500 C 932 0 F or more 200 to 850 C 328 0 to 1562 0 F 0 38 C 0 68 F for less than 400 C 752 0 F 0 48 C 0 86 F in the range from Pt500 400 C 752 0 F or more to less than 500 C 932 0 F 0 58 C 1 04 F for 500 C 932 0 F or more mV 10 to 100 mV 0 035 mV V 0 01 to 1 V 0 001 V Ohm 0 to 2000 Q 1 0 Q Note1 For T C input add Cold Junction Compensation Accuracy 0 5 C to the total accuracy Note2 For RTD input of the 2 wire connection add a corrected value 0 1 C to the total accuracy Note3 For DC miliamperes 4 to 20 mA connect external shunt resistors Note4 Explosion proofing not applicable to DC volts DC miliamperes All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt Table 2 Effects of ambient temperature Sensor Type Temperature g a Mie ae in Ambient Measurement Range 0 2 C 0 066 of t 100 t lt 300 C B 0 07 C 0 0057 of t 300 300 C lt t lt 1000 C 0 037 C t2 1000 C 0 035 C 0 00492 oft t lt 0 C i 0 035 C 0 001
6. lt lt Contents gt gt lt lt Index gt gt General Specifications GS 04R01B01 01EN YTMX580 Multi Input Temperature Transmitter JTMK ISA100 Wireless The model YTMX580 Multi Input Temperature Transmitter can accept inputs from up to 8 points of measurement such as thermocouples 8 types K E J etc or RTD signals 3 types Pt100 etc converting the corresponding measurement input values to a wireless signal It can also accept DC voltage resistance and 4 20 mADC signal input In addition to temperature signals it can also wirelessly send and receive setting parameters Internal battery power means eliminating not only signal wires but also power cables this offers great installation cost reductions The communication is compliant with 1SA100 11a protocol specifications m FEATURES e Long Life Battery Design Ultra low current consumption design using two high capacity lithium thionyl chloride batteries provide wireless operation for years e High Security Wireless Network Configuration Infrared communication between the devices for wireless network configuration and parameter setting e Quick Update Time Selectable from 1 second to 60 minutes for measured process value to publish wirelessly m STANDARD SPECIFICATIONS a WIRELESS SPECIFICATIONS Communication protocol SA100 11a protocol Data rate 250 kbps Frequency 2400 2483 5 MHz license free ISM band Radio security AES 128 bit
7. 2 Indoor Outdoor use EMC Conformity Standards EN61326 1 Class A Table 2 For use in industrial locations EN61326 2 3 EN 301 489 1 EN 301 489 17 R amp TTE Conformity Standards C ETSI EN 300 328 ETSI EN 301 489 1 ETSI EN 301 489 17 EN60950 1 EN62311 Regulation Conformity of the Wireless Module e FCC Approval e IC Approval e Japanese Radio Law Construction Design Attestation Number 007WWCUL0480 Korea Certification Radio Wave Act KCC REM YHQ WEN007 EMC and Radiocommunications regulatory arrangement in Australia and New Zealand RCM AS NZS 4268 AS NZS 2772 2 EN61326 1 Class A Table2 For use in industrial location GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt Explosion Protection FM Intrinsically safe nonincendive Approval Intrinsically Safe for Class Division 1 Groups A B C amp D Class II Division 1 Groups E F amp G and Class Ill Division 1 Class Zone 0 in Hazardous Locations AEx ia IIC Nonincendive for Class l Division 2 Groups A B C amp D Class II Division 2 Groups F amp G and Class III Division 1 Class Zone 2 Group IIC in Hazardous Locations Sensor Circuit Parameter Voc Uo 5 88 V Isc lo 130 1 mA Po 191 2 mW Ca Co 1 UF La Lo 1 mH Ambient temperature 50 to 70 C 58 to 158 F CSA Intrinsically safe Approval non incendive Approval Intrinsically Safe for Class Division 1 Groups A B C amp D Cl
8. 46 oft t20 C j 0 0039 C 0 00529 of t t lt 0 C 0 0039 C 0 00149 oft t20 C Tc K 0 00521 C 0 00707 oft t lt 0 C 0 00521 C 0 00182 oft t20 C N 0 0077 C 0 00918 oft t lt 0 C 0 0077 C 0 00136 oft t20 C 0 04 C 0 0 0102 oft t lt 100 C R S 0 0316 C 0 001 oft 100 C lt t lt 600 C 0 0175 C 0 00173 oft t2 600 C 0 00513 C 0 00631 oft t lt 0 C 0 00513 C 0 0008 oft t20 C Pt100 0 0048 C 0 0016 of absolute value t Entire Sensor Input Range PODO 0 0038 C 0 0015 of absolute value t t lt 650 C RTD 0 0028 C 0 0016 oft t2 650 C PEOD 0 003 C 0 0014 of absolute value t t lt 650 C 0 002 C 0 0016 oft t2 650 C mV 0 0002 mV 0 0015 of reading Entire Sensor Input Range V 0 005 mV 0 0015 of reading Entire Sensor Input Range Ohm 0 001 Q 0 0009 of reading Entire Sensor Input Range Note1 The t on Table 2 means the value of the reading in C Note2 The absolute value t on Table 2 means the absolute value of the reading in C Example of absolute value t When the temperature value is 250 Kelvin abs reading is 23 15 absolute 250 273 15 All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt m MODEL AND SUFFIX CODES
9. 752 0 F or more to less than 800 C 1472 0 F 1 54 C 2 78 F for 800 C 1472 0 F or more E 200 to 1000 C 328 0 to 1832 0 F 0 80 C 1 44 F for less than 0 C 32 0 F 0 40 C 40 72 F for 0 C 32 0 F or more J 180 to 760 C 292 0 to 1400 0 F 0 80 C 1 44 F for less than 0 C 32 0 F 0 70 C 1 26 F for 0 C 32 0 F or more s o o o TIC K IEC584 180 to 1372 C 292 0 to 2501 6 F aor F for less than 0 C t 1 0 C 1 80 F for 0 C 32 0 F or more N 200 to 1300 C 328 0 to 2372 0 F t 2 0 C 3 60 F for less than 0 C 32 0 F 1 0 C 1 80 F for 0 C 32 0 F or more 0 to 1768 C 32 0 to 3214 4 F 2 00 C 3 60 F for less than 200 R C 392 0 F 1 50 C 42 70 F for 200 C 392 0 F or more 0 to 1768 C 32 0 to 3214 4 F 2 00 C 3 60 F for less than 200 s C 392 0 F 1 40 C 42 52 F for 200 C 392 0 F or more T 200 to 400 C 328 0 to 752 0 F 0 70 C 41 26 F 200 to 850 C 328 0 to 1562 0 F 0 30 C 0 54 F for less than 400 C 752 0 F 0 40 C 0 72 F in the range from Pt100 400 C 752 0 F or more to less than 500 C 932 0 F 0 50 C 0 90 F for 500 C 932 0 F or more 200 to 850 C 328 0 to 1562 0 F 0 54 C 0 98 F for
10. and instruction manual 2 If you need F9915NS please purchase F9915NK F9915NK is a set of F9915NS and instruction manual Model Surffix Code Description YTMXBP Blind plug for electrical connection A1 G 1 2 1 piece A4 G 1 2 4 pieces A7 G 1 2 7 pieces C1 1 2 NPT 1 piece Type and Quantity C4 1 2 NPT 4 pieces C7 1 2 NPT 7 pieces D1 M20 1 piece D4 M20 4 pieces D7 M20 7 pieces All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt m DIMENSIONS e 2 inch pipe mounting vertical or horizontal pipe Unit mm approx inch 147 3 5 80 67 3 45 2 2 65 1 78 Mounting bracket 164 6 46 Tr 173 6 81 110 4 33 89 5 3 52 ae lt 118 4 65 120 4 72 118 4 65 133 8 5 27 O D 60 mm Electrical connection 48 48 48 48 o Height of directly attach the remote antenna to the body a S 2 x o g N 1 89 ov its g ite rep ce Y E02 ai Note If not specified the tolerance is 3 However for dimentions less than 10 mm the tolerance is 0 3 mm All Rights Reserved Copyright 2011 2014 Yokogawa Electri
11. ass Il Division 1 Groups E F amp G Class Ill Division 1 Non incendive for Class Division 2 Groups A B C amp D Class II Division 2 Groups F amp G Class III Division 1 Enclosure Type 4X IP66 IP67 Temperature Code T4 Ambient temperature 50 to 70 C Ex ia IIC T4 Sensor Circuit Parameter Uo 5 88 V lo 130 1 mA Po 191 2 mW Co 1 pF Lo 1 mH ATEX Intrinsically safe Approval Il 1 G Ex ia IIC T4 Ga Sensor Circuit Parameter Uo 5 88 V lo 130 1 mA Po 191 2 mW Co 1pF Lo 1 mH Ambient temperature 50 to 70 C IECEx Intrinsically safe Approval Ex ia IIC T4 Ga Sensor Circuit Parameter Uo 5 88 V lo 130 1 mA Po 191 2 mW Co 1 pF Lo 1 mH Ambient temperature 50 to 70 C TIIS intrinsically safe Approval Ex ia IIC T4 X Power Supply Battery pack F9915MA or battery case F9915NS DC7 2V Sensor Input Circuit Uo 5 88 V lo 130 1 mA Po 191 3 mW Co 1 u F Lo 1 mH Ambient temperature 20 to 60 C The remote antenna model antenna suffix code B is not applicable All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation a PHYSICAL SPECIFICATIONS Enclosure Housing Low copper cast aluminum alloy Coating e Standard coating polyurethane mint green paint Munsell 5 6 BG 3 3 2 9 or its equivalent e High anti corrosion coating Option Code X2 Base coating epoxy resin coating Finish coating polyurethane coating The color is same as standard type
12. c Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt 9 e Wall mounting Unit mm approx inch Mounting bracket 256 10 08 143 5 63 256 10 276 10 87 0 39 48 48 48 48 Electrical connection a Height of directly attach the remote antenna to the body 2 02 1 18 48 1 89 4 06 2 hole a Wall mounting dimensions or M5 tapping 1 64 0 5 6 46 0 02 a 1 256 0 5 10 08 0 02 ez Note If not specified the tolerance is 3 However for dimentions less than 10 mm the tolerance is 0 3 mm All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 10 lt lt Contents gt gt lt lt Index gt gt e Remote antena bracket Unit mm approx inch 17 0 67 71 7 2 82 37 3 1 47 17 5 0 69 L gt eoe yj I S t9 x Q al F 1 I lt Lee SIN 62 19 o 3 7 g Y Y H B a minimum R67 bJ 2 inch pipe a 98 3 86 J04 ai e Remote antenna Antenna cable Antenna Antenna High frequency coaxial cable Non direction antenna Sheath dia 11 11mm Gain 2 dBi lt Without ar
13. codified RF Transmitter power Max 11 6 dBm fixed Antenna 2 dBi Omni directional type a PERFORMANCE SPECIFICATIONS Accuracy See Table 1 Cold Junction Compensation Accuracy For T C only 0 5 C 0 9 F added to accuracy when using thermocouple input Ambient Temperature Effect per 1 0 C change See Table 2 Battery Pack Battery pack with long life lithium thionyl chloride batteries With the intrinsically safe type the battery pack is replaceable in a hazardous area Typical battery life is 6 years at 60 seconds publication period update time in the following conditions e Network connection JOIN status e Ambient temperature 2342 C e Device role IO function only LED indicator off Environmental condition such as ambient temperature and vibration may affect the battery life m FUNCTIONAL SPECIFICATIONS Input channels 8 points Input type is selectable Thermocouples 2 3 and 4 wire RTDs ohms DC milivolts and DC miliamperes 4 to 20 mA with external shunt resistors See Table 1 Note Explosion proofing not applicable during DC volts and DC miliamperes input Maximum Allowable Input voltage 2 5 VDC Category O Transient overvoltage 330V Input Resistance 10 MO or more Input Signal Source Resistance for T C mV 1 KQ or lower Input Lead Wire Resistance for RTD Ohm 10 Q per wire or lower Output Wireless ISA100 11a protocol 2 4 GHz signal YOKOGAWA Yokogawa Ele
14. ctric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan GS 04R01B01 01EN Copyright September 2011 7th Edition Feb 27 2014 lt lt Contents gt gt lt lt Index gt gt Measurement Range See Table 1 Publication Period Update Time 1 to 3600 sec selectable Minimum of 2 seconds with 4 or more measuring points Zero gain Adjustment Set the amount of zero gain point adjustment Status Display The RDY green and ALM red LEDs indicate the following statuses Starting Running Waiting to JOIN network Squawk Alarm Deep Sleep Sensor Burnout Select HIGH LOW or OFF as the configuration use setting software Self Diagnostics Amplifier failure sensor failure configuration error battery alarm wireless communication alarm and over range error for process variables Software Download Function Software download function permits to update wireless field device software via ISA100 11a wireless communication Device Role The following 2 device roles are supported depending on the network topology e lO Function only IO e lO Function and Routing Function IO Router Device Role IO Star lO Router Mesh SE Network form Example network connections and devices GW Gateway GW Gateway IO YTMX580 IO R YTMX580 IO YTMX580 E01 ai Infrared Communication Data rate 9600 bps Distance Infrared surface of the near infrared adapter should be withi
15. e unit for all inputs will be the same It is not necessary to specify the unit of mV V and ohm inputs for these units automatically will be mV V or Ohm 3 Tag Number if required Specify Tag number up to 16 letters to be engraved on the tag plate Also the specified letters are written to the Tag_Name 16 letters of the amplifier memory The characters can be specified using alphanumeric and the symbols and Do not write anything to Tag number when nothing is engraved on the tag plate 4 Software tag if required Specify this software tag when the tag number required is different from the tag number specified for the Tag plate The tag number specified in Software tag will be entered on Tag_Name up to 16 letters in the amplifier memory Note Lower case alphabet characters and periods cannot be used in Yokogawa s configuration software Specify the tag name Tag_Name using a combination of upper case alphabet characters numbers and hyphens lt Factory Setting gt Table A Settings upon shipment Tag No Blank or as specified in order Calibration range and unit See Table 1 Measurement Range or as specified in order All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation Subject to change without notice 12 lt Related Instruments gt Field Wireless Integrated Gateway YFGW 710 Refer to GS 01W01F01 01EN Field Wireless
16. ent is shipped with the settings shown in Table A 1 Sensor type 1 Select an input sensor type from table 1 Each input is of the same type 2 For RTD and resistance input specify the number of wire as well Example Pt100 3 wire system 3 With the FC1 option Factory configured settings with multiple input types ranges please indicate the type of sensor for each input You can also select NOT_USED for inputs 2 through 8 Note1 If the option code related to explosion protection is specified Either DCV mV or DCV V as sensor type is should NOT be applied Note2 If the period of measurement is 1 second the maximum number of measuring points is 3 At a 1 second period the sensor type for at least 5 points must be set to NOT_USED 2 Calibration range and unit if required 1 Calibration range can be specified within the measurement range shown in Table 1 With the FC1 option please indicate the upper and lower limit values for each input If FC1 is not specified the upper and lower limit values for all inputs will be the same 2 Please specify the units of temperature for each input C K F or R F and R are available when Temperature Unit suffix code B is specified In Japan F and R are non statutory measurement units Suffix code B can only be specified by end users outside of Japan With the FC1 option please indicate the unit for each input If FC1 is not specified th
17. n 30 cm Power Supply 2x primary lithium thionyl chloride batteries size D With battery case batteries sold separately Insulation Resistance Measuring input terminal to ground terminal 100 MQ or greater at 500 VDC Dielectric Strength Dielectric strength that can withstand the following conditions Measuring input terminal to ground terminal 500 VAC 50 60 Hz 1 min leakage current of 5 mA or less Between measuring input terminal 200 VAC 50 60 Hz 1 min leakage current of 5 mA or less All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation a NORMAL OPERATING CONDITION Optional features or approval codes may affect limits Ambient Temperature Limits 40 to 85 C 40 to 185 F As for explosion protect type see REGULATORY COMPLIANCE STATEMENTS Ambient Humidity Limits 0 to 100 RH Storage Temperature 40 to 85 C 40 to 185 F Vibration 3G or less at resonant frequencies from 10 to 2000 Hz IEC 60770 1 m REGULATORY COMPLIANCE STATEMENTS This device contains the wireless module The wireless module satisfies the following standards Please confirm that a installation region fulfills a standards require additional regulatory information and approvals contact to Yokogawa Electric Corporation Safety Standards EN61010 1 EN61010 2 030 CSA C22 2 No 61010 1 12 CSA C22 2 No 61010 2 030 12 UL 61010 1 UL 61010 2 030 CSA NRTL C Overvoltage Category Pollution Degree
18. rester gt lt With arrester gt Part number F9193DH x im Antenna e DA 20 5 Antenna a Cable 2 Length 3 mor 10 m selectable af _ Arrester Cable t Length 1mor3m Cable 1 selectable Length 1mor3m z selectable P co 4 P Main unit Main unit E05 ai Note If not specified the tolerance is 3 However for dimentions less than 10 mm the tolerance is 0 3 mm All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt 1 1 e Infrared Configuration e Terminal Configuration oon mm me mm om cama wa ga na a Ta slekel ololclelelelelelelelelaleleicicielo o ao Infrared port E06 ai Ground terminal O OOQ a li J Ground terminal E07 ai e Input Wiring 1o 03 1 03 2 04 o2 04 A B TC or DC millivolts two wire three wire four wire RTD or ohm RTD or ohm RTD or ohm E08 ai lo 03 4 20mA Enq Power device 50Q supply DC milliamperes use a shunt resistor All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt lt Ordering Information gt Specify the following when ordering Model suffix codes and optional codes The instrum
19. rosion coating IX2 Factory configured settings Factory configured settings with multiple input types ranges IFC1 m OPTIONAL SPECIFICATION For Explosion Protected type Item Description Option Code Canadian Standards Association CSA CSA Intrinsically safe and non incendive approval ICS17 Factory Mutual FM FM intrinsically safe and nonincendive approval IFS17 1 TIIS TIIS intrinsically safe approval JS37 1 2 ATEX ATEX intrinsically safe approval IKS27 IECEx Scheme IECEx intrinsically safe approval ISS27 1 CS17 FS17 JS37 KS27 SS27 cannot be specified together 2 JS37 can be specified on Integral antenna models Suffix Code for Antenna is A E Standarad Accessories Product User s manual Booklet Qty Mounting bracket 2 inch pipe mounting or wall mounting 1 set Battery case installed in the main body 1 Remote antenna 1 1 Not included if specifying no mounting brackets mounting bracket suffix code is N 2 With the remote antenna option Antenna Type suffix code B All Rights Reserved Copyright 2011 2014 Yokogawa Electric Corporation GS 04R01B01 01EN Feb 27 2014 00 lt lt Contents gt gt lt lt Index gt gt E Optional Accessories Product Model code part number Specification Remote antenna cable F9193UA Antenna cable 1 m Operational temperature range