User Manual Intelligent Power System (iPS)

image

Contents

1. age definitions To battery To device Figure 2 10 Cable connection After all cables are well connected turn on the battery power by pressing the power button hold for 7 seconds on the remote control again and the battery is ready to supply DC power to device 2 4 2 Discharging Time Estimation To estimate discharging time you must need to know the power consumption of the loader PC or Device For example assuming power consumption of the loader is 40Wh discharging time for different capacities of iPS M batteries is listed following Model Discharging Time Estimation IPS M420S 8 10 hours 400Wh 40 Wh IPS M210S 4 5 hours 200Wh 40Wh iPS M S series User Manual V A1 10 2 4 3 Low Capacity Warning When the battery capacity is lower than 10 battery protection will be active to pre vent battery over discharging There are 2 scenarios 1 When the battery level is lower than 10 during continuous use The Red LED keeps flashing and a warning beep sound is triggered The beep ing sound will continue until the AC power is plugged in When battery capacity is 0 the battery system shuts down automatically 2 Turning iPS on when battery capacity is lower than 10 If the battery capacity is less than 10 initially when you press the power on button on the remote control to turn on the battery the Red LED on the remote will keep flashing and a warning beep sound is triggered The beeping sound will
2. concrete or ceramic tile If floors are covered with synthetic material the rel ative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital IEC 61000 4 4 output output environment lines lines en 5 oo n Mains power quality Surge should be that of a typical IEC 61000 4 5 2 kV line s to 2 kV line s to commercial or hospital u environment earth earth Power frequency mag Power frequency ee 50 60 Hz netic fields should be at magnetic field IEC 61000 4 8 3 A m 3 A m levels characteristic of a typical location in a typi cal commercial or hospi tal environment iPS M S series User Manual V A1 20 interruptions and voltage variations on power supply input lines IEC 61000 4 11 lt 5 UT gt 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles lt 5 UT gt 95 dip in UT for 5 sec lt 5 UT gt 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles lt 5 UT gt 95 dip in UT for 5 sec Mains power quality should be that of a typical commercial or hospital environment If the user of the model IPS M Bat tery requires continued operation during power mains interruptions it is recommended that the model IPS M Battery be powered from an uninter ruptible powe
3. ee een 20 ix IPS M S series User Manual V A1 iPS M S series User Manual V A1 Chapter 1 General Information 1 1 Introduction iPS is an intelligent power system designed to provide DC power to various equip ment in a mobile environment With a Lithium Iron Phosphate LFP cell iPS has a larger battery capacity and lighter weight than traditional battery systems Lead Acid Also LFP batteries are more safe stable and clean than other types of battery iPS is suitable to be installed in mobile carts which are used in hospitals and other applications that need higher standard of safety and environmental safety 1 2 Specifications iPS M S Series Category Attribute iPS M420S iPS M210S Battery Type Lithium Iron Phosphate Battery Capacity 400Wh 200Wh Battery Life SPAN DOD 80 2000 cycles DOD 80 1000 cycles Charge Time lt 3hr DOD 100 lt 1 5hr DOD 100 Power Supply Input Voltage 100 240Vac 50 60H Max 4 5A System 1 19 Vdc Max 6A DES Nomade System 2 12 Vdc Max 5A Charging Status LEDs with continuous readout intelligent software Indicators DC Output Inter Dc Jack 4 pin mini lock din face I O Ports Cc icati ommunication RS 232 Interface Vibration 5 500Hz 1G Environment Cooling System Fanless Water Resistance IP67 DC output connector Dimensions L x W 282 x 260 x 101 mm 11 1 x 10 2 x 3 9 inch x H Physical Charac teris
4. continue until AC power is plugged in When battery capacity is 0 the bat tery system shuts down automatically RED LED keeps flashing Warning When the battery capacity is 0 you MUST RECHARGE WITHIN 48 HOURS to keep the battery cell alive and extend the battery life 11 IPS M S series User Manual V A1 2 5 Battery Pack Replacement iPS M power system allows to do battery pack replacement in just 4 easy steps 1 Turn AC power switch off Turn off switch Turn off switch 2 Remove top cover screws and top cover iPS M S series User Manual V A1 12 3 Remove screws on battery pack holder 4 Disconnect battery cell cable and system cable to remove old battery cell and replace new one 5 Reverse above steps to reassemble the battery system 13 IPS M S series User Manual V A1 IPS M S series User Manual V A1 14 Chapter 3 Battery Maintenance 3 1 Regular Use There are 3 key points you need to know when maintaining the battery system 1 When the battery is new immediately recharge it to 100 before first use 2 When power capacity is lower than 30 and the LED indicator appears orange plug the AC power to recharge 3 If battery is over discharged and the PC or connected devices are shut down or powered down The battery must be recharged within 48 hours 2 days to main tain the battery life 3 2 Storing the Battery If the battery system or battery pack is going to b
5. EMC Table 4 1 EMC Table Guidance and manufacturer s declaration electromagnetic emissions The model IPS M power system is intended for use in the electromagnetic environments specified below The customer or the user of the model IPS M power system should be assured that it is used in such an environment Emissions test Compliance ance Electromagnetic environment guid Conducted Radiated EN 60601 1 2 Harmonic emissions IEC 61000 3 2 Voltage fluctuations amp flicker emissions IEC 61000 3 3 The model IPS M is suitable for use in all establishments including domestic estab lishments and those directly connected to the public low voltage power supply net work that supplies buildings used for domestic purposes Guidance and manufacturer s declaration electromagnetic immunity The model IPS M power system is intended for use in the electromagnetic environment specified below The customer or the user of the model IPS M power system should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic envi ronment guidance Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst 6 kV contact 8 kV air 2 kV for power supply lines 1 kV for input 6 kV contact 8 kV air 2 kV for power supply lines 1 kV for input Floors should be wood
6. Intelligent Power System iPS IPS M S series Power System AD ANTECH Enabling an Intelligent Planet Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Declaration of Conformity FCC Class B Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful i
7. Started 2 1 Overview of IPS M Power System Before starting to use IPS take a moment to become familiar with the functions of connectors switches and ports which are illustrated in the figures below 1 System 2 12 Voc 5 A 5 AC In and AC On Off switch 2 System 1 19 Voc 6A 100 240 Vac F4A 3 6 pin remote control connector 6 AC input switch 4 RJ 45 to RS 232 connector 7 Ground pole Figure 2 1 I O Ports and AC Connector The front side view figure 2 2 AC On Off Switch Figure 2 2 Front and Top View with AC Switch iPS M S series User Manual V A1 6 2 2 Overview of IPS M Remote Control Remote control is a switch for IPS There is one Power On Off button and LED indicator to display battery capacity See figure 2 4 for button and LED indicator Power On Off Button LED Indicator Figure 2 3 Remote Control 2 3 Battery Charging When purchasing the iPS M Power System you MUST perform a battery charge before providing power to other devices To do a battery charge connect the AC power cord and turn on the AC power switch beside the AC IN connector on the front side Also connect the remote control to the battery and press the power on button press and hold for at least 7 seconds to turn on power Plug AC power cord Turn on switch Figure 2 5 AC power cord connecting and power switch on 7 IPS M S series User Manual V A1 Turn on switch Figure 2 6 AC power switch on Connect remo
8. at people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted Ifthe equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel MH The power cord or plug is damaged Liquid has penetrated into the equipment m The equipment has been exposed to moisture a The equipment does not work well or you cannot get it to work according to the user s manual The equipment has been dropped and damaged V iPS M S series User Manual V A1 15 16 17 18 19 20 MH The equipment has obvious signs of breakage Do not leave this equipment in an environment where the storage temperature may go below 20 C 4 F or above 60 C 140 F This could damage the equipment The equipment should be in a controlled environment Follow national state or local requirements to dispose of unit Contact information No 1 Alley 20 Lane 26 Rueiguang Road Neihu District Taipei Taiwan 114 R O C TEL 886 2 2792 7818 This equipment shall not be used as a life support system Grounding reliability can only be achieved when
9. e stored in a warehouse for a long time the following tasks need to be performed 1 When battery is new recharge it to 100 immediately before moving to the warehouse 2 Before storing the battery and leaving it in idle status it must be recharged to 100 3 If battery is not to be used or put in idle mode for a long time recharge to 100 than move to the warehouse It is also suggested to perform a recharge regu larly For 400Wh power system every 1 year For 200Wh power every 6 months iPS M S series User Manual V A1 16 3 3 Trouble Shooting When the battery system runs abnormally such as 1 Failure to power on 2 Failure to power off 3 Remote LED ON but no DC power output 4 AC power in and all switches ON but the battery doesn t recharge There is a reset button on battery system follow these recovery steps 1 Press the reset button once when battery power is down remote LED off 2 Press power button hold for 7 seconds on Remote Control to power on the battery 3 When the LED lights up again the battery system is recovered SYSTEM2 SYSTEM1 Reset Button Warning When battery is going to be stored for a long time make sure to recharge it to 100 capacity If stored in a warehouse over 1 year you A need to do regular recharges Every year for 400Wh power system Every 6 months for 200Wh power system 17 IPS M S series User Manual V A1 IPS M S series User Manual V A1 18 Chapter 4
10. equipment which are not authority to operate the equipment expressly approved by the relevant standards authority could void your Caution Danger of explosion if battery is incorrectly replaced manufacturer Dispose of used batteries according to the manufacturer s instructions N Replace only with the same or equivalent type recommended by the Note Notes provide optional additional information Packing List Before setting up the system check that the items listed below are included and in good condition If any item does not accord with the table please contact your dealer immediately iPS M series battery system x 1 4 PIN Ring Terminal cable x 1 4 PIN DC Jack cable x 1 6 PIN Remote control cable x 1 RJ45 RS232 console cable x 1 Warranty card x 1 iii iPS M S series User Manual V A1 Additional Information and Assistance 1 2 Visit the Advantech websites at www advantech com or www advantech com tw where you can find the latest information about the product Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages T
11. his equipment is a source of electromagnetic waves Before use please make sure that there are not EMI sensitive devices in its surrounding which may mal function therefore Warning To prevent electric shock turn off AC power or unplug AC power cord N before remove cover Caution 1 Please contact a qualified technician or your retail provider for bat tery replacement Do not do it by yourself A 2 There is a danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Discard used batteries according to the manufac turer s instructions iPS M S series User Manual V A1 iv Safety Instructions 10 11 12 13 14 Read these safety instructions carefully Keep this User Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equip ment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so th
12. lec tronic components iPS M S series User Manual V A1 viii Contents Chapter Chapter Chapter Chapter 1 s O1 amp ND 2 4 2 5 4 1 General Information 1 Introduction a een en aan 2 Specifications emitir da dia ips ias 2 Remote Control Specifications 3 DC to DC Converter Specifications 3 DIMENSIONS csi dd dans 4 Getting Started 5 Overview of IPS M Power System 6 Figure 2 1 I O Ports and AC Connector 6 Figure 2 2 Front and Top View with AC Switch ee 6 Overview of IPS M Remote Control 7 Figure 2 3 Remote Control us 7 Battery Charging 225se nee 7 Figure 2 4 Connecting the AC power cord with iPS M battery 7 Figure 2 5 AC power cord connecting and power switch on 7 Figure 2 6 AC power switch on 8 Figure 2 7 Connecting the remote control 8 Figure 2 8 Power ON battery 8 Battery Discharging u anne en 9 24 1 Device Connection determine dan 9 Figure 2 9 Battery power off 9 Figure 2 10Cable connection 10 2 4 2 Discharging Time Estimation oooconnnnccnnnnnncccccnnnnconccccnnnnnnccnnnnnns 10 2 4 3 Low Capacity Warning 11 Battery Pack Replacement ran nnnnnannn nn 12 Battery Maintenance 2 19 Regular USC cctv italien 16 Storing the Battery tpm imnn tiss nm nations 16 Trouble Shooting ifs seen return tait ae 17 ENG Table ee ce I EMG Table
13. nd electronic prod ucts carrying the mark left must be disposed of sepa rately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your display products please follow the guidance of your local author ity or ask the shop where you purchased the product or if applicable follow any agreements made between your self The mark on electrical and electronic products only applies to the current European Union Member States iPS M S series User Manual V A1 vi Explanation of Graphical Symbols IEC 60878 and ISO 3864 B 3 6 Warning dangerous voltage AN ISO 7000 0434 Attention consult ACCOMPANYING DOCUMENTS BE ISO 7000 1641 Follow operating instructions or Consult instructions for use D IEC 60417 5009 SANDY BY m IEC 60417 5031 Direct current JEC 60417 5017 Earth ground IEC 60417 5021 Equipotentiality vii iPS M S series User Manual V A1 Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage m To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on m Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive e
14. nter ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer ence to radio or television reception which can be determined by turning the equip ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver E Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Part No 2008M42010 Edition 1 Printed in Taiwan July 2014 iPS M S series User Manual V A1 ii Technical Support and Assistance 1 2 Visit the Advantech website at http support advantech com where you can find the latest information about the product Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages Warnings Cautions and Notes Warning Any changes or modifications made to the
15. r supply or another battery NOTE UT is the a c mains voltage prior to application of the test level 21 IPS M S series User Manual V A1 AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies O Advantech Co Ltd 2014
16. te control Figure 2 7 Connecting the remote control Press the power button and hold for 7 seconds to turn on battery power Figure 2 8 Power ON battery iPS M S series User Manual V A1 8 When the battery is charging an LED indicator keeping flashing If the battery capac ity reaches 100 the LED indicator stops flashing and all LEDs are bright Caution After purchasing the new iPS M power system you must charge the battery to 100 which keeps the battery cell in active status and A extends battery life Caution When charged to 100 its best to remove AC power to prevent OVER CHARGING which may decrease battery life 2 4 Battery Discharging iPS M power system provides 2 output modes to provide power to loader PC or other devices DC power can provide from one of each DC output port or both ports Max Watt for System 1 and System 2 output System 1 19V x 6A 114W System 2 12V x 5A 60W Maximum output is around 174W 2 4 1 Device Connection Before connecting equipment to iPS M power system turn off battery power from the remote control first Then connect the cable to the battery system and equipment Press power button and hold for 7 seconds to turn off battery power When power is off all LED light will go off m eo ao k d Figure 2 9 Battery power off 9 IPS M S series User Manual V A1 Connecting iPS M cable to System 1 or System 2 port depends on equipment volt
17. the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade Use a power cord that matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein Warning A Warning A Caution 1 Input Voltage rate 100 240V 47 63Hz 4 5A Max 2 Output Voltage rate System1 19V 6A Max System2 12V 5A Max Do not modify this equipment without authorization of the manufac turer To avoid risk of electric shock this equipment must only be con nected to a supply mains with protective earth To prevent electric shock turn off AC power or unplug AC power cord before remove cover To disconnect this product from the mains supply disconnect the mains plug from the socket outlet The power supply is regarded as part of this equipment Please contact a qualified technician or your retail provider for bat tery replacement Do not do it by yourself There is a danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Discard used batteries according to the manufac turer s instructions Within the European Union EU wide legislation as implemented in each Member State requires that waste electrical a
18. tics Weigh ekg akg Certifications UL60601 1 EN60601 1 CE FCC Class B CCC certified Battery capacity indicator Alerts battery capacity temperature warning Battery Life cycle statistics Report amp log file Power Manager AMIS Link Client Installation Server Installation Optional Multi language support including Chinese Tradi tional Chinese Simple English German and Dutch Software iPS M S series User Manual V A1 2 1 3 Remote Control Specifications Category Attribute iPS REMT Physical Dimensions L x W x H 80 x 48 x 14 mm 3 1 x 1 8 x 0 5 inch Characteristics Weight 0 3kg Display amp Power Button Battery power button Controller LED Display LED Indicator 1 4 DC to DC Converter Specifications Category Attribute iPS REMT Physical Dimensions L x W x H 54 x 23 x 12 mm 2 1 x 0 9 x 0 4 inch Characteristics Weight 0 4kg DC In 12 24Vdc 8 3A Mode 1 12Vdc 6A I O ports DC Out Mode 2 15Vdc 5A Mode 3 16Vdc 5A Mode 4 19Vdc 4A IPS M S series User Manual V A1 1 5 Dimensions 282 tor r N ss i Anar 18 420 gt EET og ie a oo o o z 1 e 20 E iPS M S series User Manual V A1 4 Chapter 2 Getting