Home
SWS Series User`s Manual (Rev. 050817)
Contents
1. and Category 9 monitoring x and control instruments Most of Harvard Apparatus products fall into either Category 8 or and are currently exempt from the RoHS Directive Do Not Dispose Product with Harvard Apparatus will continue to monitor the application of the RoHS Municipal Waste Directive to its products and will comply with any changes as they apply Special Collection Disposal Required Warner Instruments A Harvard Apparatus Company
2. SWS Manual Rev 050817 Warner Instruments SWS Series Syringe Heater Warner Instruments 1125 Dixwell Avenue Hamden CT 06514 800 599 4203 203 776 0664 203 776 1278 fax CC SWS Manual Rev 050817 Table of Contents INTRODUCTION sau NOMENCLATURE 230322 ee nina anaa aaan ES EDIT RETERTETERT OPERA VION aaa eignen Setlline Tili s ai reed AERE PUER EE IDEE RN NIENTE RN M Nm EE APPENDIX Go ee SPECIHCAUODS e Accessories and replacement parts e eee eee e eee eee eee e seats eese esee osse sete esee esos sese eese e esos osos sette eeeee Warranty and Sec VICE oe eere eee TUNI ae IIa tv UR I aie ie E i ii NOTTS NOR Tcr E Deco NOTEN es ee ie bubus ee ee re Cerina 0 eee i ns ent RP RO RE SR Oe OS nN SWS Manual Rev 050817 3 The SWS Syringe Warmer System from Warner Instruments is comprised of a SWS syringe warmer and a TC 124 temperature controller This capable system is designed to conveniently warm solutions in a syringe for use in a variety of applications The compact design of the warmer allows it to be used either with a syringe pump or mounted on a support stand The model number of the specific syringe warmer SW 10 SW 60 indicates the size syringe to which it fits In general reservoir heating is an important technique used to deliver warmed solution of a bath or to eli
3. Syringe Heater is designed to be mounted directly onto a syringe body The heater mounted syringe can the be mounted onto a syringe pump support stand or hand manipulated Temperature regulation is maintained via Warner s TC 124 mini temperature controller Instructions for the function and use of the TC 124 is provided in a separate user s manual The SWS Syringe Heater have two o rings mounted into grooves in the top of the unit which serve to provide a gripping mechanism for inserted syringes As a result a syringe can be partly or completely inserted into the heater body SETUP 1 Place the TC 124 temperature controller in a convenient location Do not plug the device in yet 2 Place an appropriately sized syringe into the syringe heater Mount the syringe to a support stand or perfusion pump 3 Attach a stopcock to the Luer fitting on the syringe and run perfusion lines from the syringe to your setup 4 Connect the power cord from the syringe heater to the input channel on the temperature controller o Plug the TC 124 in and adjust the unit to the solution temperature See the TC 124 User s Manual Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 6 OPERATION The main use of a heater control device such as the TC 124 is to maintain a constant solution temperature with a minimum deviation from the set temperature Settling Times A feedback sensor for the temperature
4. controller resides within the aluminum block of the SWS Series heater Consequently the Read Temperature reported by the device is actually that of the heater block Therefore it is important to allow enough time for the system to reach equilibrium so that the reported temperature is also that of the solution being warmed Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 7 APPENDIX Specifications SWS Series Syringe Warmers Heater resistance 10 0 Temperature range 25 50 C Input voltage 12V nominal 16V max mem memo nm NN m amo man Syringe Type Becton Dickinson Becton Dickinson Equipment is intended to be operated in a controlled laboratory environment Operating conditions Temperature 0 40 C Altitude sea level to 2000 m Relative humidity 0 95 Accessories and replacement parts Description Model No Order No Syringe Warmer for 10 cc syringes SWS 10 64 1584 Syringe Warmer for 60 cc syringes SWS 60 64 1560 Syringe Warmer for 140 cc syringes SWS 140 64 1585 Temperature Controller US TC 124 64 1545 Temperature Controller EU TC 124E 64 1545E Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 8 Warranty and service Warranty The SWS Series Syringe Warmer is covered by our Warranty to be free from defects in materials and workmanship from the date of shipment for a period of one year If a failure occurs within this period we will either repair o
5. ilable 3 Insure the shipment for its full value 4 Include an explanation of the problem with the shipment Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 Certifications Declaration of Conformity CE MARKING EMC Application of Council Directive 89 336 EEC Standards To Which Conformity Is Declared Manufacturer s Name Manufacturer s Address Equipment Description Equipment Class Model Numbers EN55022 Class A EN61000 3 2 EN61000 3 3 EN50082 1 1992 EN61000 4 2 EN61000 4 3 ENV50204 EN610000 4 4 EN610000 4 8 EN610000 4 11 Warner Instruments LLC 1125 Dixwell Avenue Hamden CT 06514 Tel 203 776 0664 Power Controller ITE Class A TC 124 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Place Hamden Connecticut USA pah gri Full Name Burton J Warner Signature Position President Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 10 Declaration of Conformity CE MARKING LVD Application of Council Directive 73 23 EEC Standards To Which Conformity Is Declared Manufacturer s Name Manufacturer s Address Equipment Description Equipment Class Model Numbers EN61010 1 1993 Warner Instruments LLC 1125 Dixwell Avenue Hamden CT 06514 Tel 203 776 0664 Power Controller Safety requirements for electrical equi
6. minate outgassing in heated solutions Since solution gas loading has a dependence on pressure and temperature preheating a solution at atmospheric pressure prior to delivery to a warmed environment can minimize the occurrence of bubbles in the bath even if the solution is allowed to cool enroute Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 4 NOMENCLATURE Text conventions This manual refers to instrument controls at two functional levels specific controls and settings of these controls To minimize the potential for confusion we have employed the following text conventions Since our goal is to provide clarity rather than complexity we welcome any feedback you may wish to provide Warner Instrument product numbers are presented using bold type References to controls are specified using SMALL CAPS gt References to control settings are specified using italic type Special comments and warnings are presented in highlighted text Any other formatting should be apparent from context Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 9 SYSTEM DESCRIPTION A syringe heating system is comprised of one or more syringe heaters and a temperature controller These devices work in concert to provide temperature control of bulk solutions prior to delivery to a warmed environment The SWS Syringe Heater is one component of such a syringe heating system The SWS
7. pment for measurement and laboratory use Class I TC 124 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Place Hamden Connecticut USA Signature Full Name Burton J Warner Position President Warner Instruments A Harvard Apparatus Company SWS Manual Rev 050817 11 WEEE RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers Harvard Apparatus is committed to being a good corporate citizen As part of that commitment we strive to maintain an environmentally conscious manufacturing operation The European Union EU has enacted two Directives the first on product recycling Waste Electrical and Electronic Equipment WEEE and the second limiting the use of certain substances Restriction on the use of Hazardous Substances RoHS Over time these Directives will be implemented in the national laws of each EU Member State Once the final national regulations have been put into place recycling will be offered for those Harvard Apparatus products which are within the scope of the WEEE Directive Products falling under the scope of the WEEE Directive available for sale after August 13 2005 will be identified with a wheelie bin symbol Two Categories of products covered by the WEEE Directive are currently exempt from the RoHS Directive Category 8 medical devices with the exception of implanted or infected products
8. r replace the faulty component s This warranty does not cover instrument failure or damage caused by physical abuse or electrical stress inputs exceeding specified limits In the event that instrument repairs are necessary shipping charges to the factory are the customer s responsibility Return charges will be paid by Warner Instruments Our offices are located at 1125 Dixwell Avenue Hamden CT 06514 Normal business hours are 8 30 AM to 5 00 PM EST Monday through Friday and we can be reached by phone at 800 599 4203 or 203 776 0664 Our fax number is 203 716 1278 We can also be reached by e mail at support warneronline com or through our Web site at http www warneronline com Service notes Please refer all questions regarding service to our Engineering Department A Should service be required please contact the factory The problem may often be corrected by us shipping a replacement part Factory service if required will be expedited to minimize the customer s inconvenience Instruments are inspected immediately upon receipt and the customer is notified if the repair is not covered by our warranty Repairs can often be completed in 1 2 days from our receipt of the instrument B Iffactory service is required please observe the following instructions 1 Obtain an RMA from Warner Instruments 2 Package the instrument with at least 3 inches of cushioning on all sides Use the original shipping carton if it is ava
Download Pdf Manuals
Related Search
Related Contents
Char-Broil 463720110 Charcoal Grill User Manual CAN - Cod. vec568 R2 Samsung Bezsáčkový vysavač, 850 W MCS9865 Win 98/ME User Manual GE 20-27 Refrigerator User Manual Umwelt- und Gesundheitsanforderungen an 5075 - Lega srl costruzioni apistiche Precisa Balance BJ165 Series Handbook Simplicity 6216 Lawn Mower User Manual Copyright © All rights reserved.