Home

MICROSENS - TeraMile

image

Contents

1. 0060A7123456 Port o1 e Delete Help Static MAC Addresses interface MAC Filtering By filtering MAC address the switch can easily filter the pre configured MAC address and reduce the un safety You can add and delete filtering MAC address MAC Address Table MAC Filtering Static MAC Addresses D MAC Filtering All Mac amp ddresses Multicast Filtering lA amp 2B3Cc4D3ESBF SIBZCSD4ESF6 MAC Address lae4cSasbedif Delete Help MAC Filtering interface e MAC Address Enter the MAC address that you want to filter Add e Click e f you want to delete the MAC address from the filtering table select the MAC address MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 63 83 l Delete and click All MAC Addresses You can view all of the MAC addresses learned by the selected port e Select the port number e The selected port of static amp dynamic MAC address information will be displayed in here l Clear MAC Table l l l e Click to clear the dynamic MAC addresses information of the current port shown on the screen MAC Address Table All Mac Addresses Static MAC Addresses MAC Filtering All Mac Addresses Multicast Filtering Port Mo Port 02 112244335555 STATIC 334455552211 STATIC FFESDZLCCZISF STATIC Dynamic Address Cou
2. RSTP System Configuration interface RSTP Port Configuration This web page provides the port configuration interface for RSTP You can assign higher or lower priority to each port Rapid spanning tree will have the port with the higher priority in forwarding state and block other ports to make certain that there is no loop in the LAN e Select the port in the port column field e Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 e Priority Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 e Admin P2P The rapid state transitions possible within RSTP are dependent upon whether the port concerned can only be connected to exactly another bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means the port is regarded as a point to point link False means the port is regarded as a shared link Auto means the link type is determined by the auto negotiation between the two peers e Admin Edge The port directly connected to end stations won t create bridging loop in the network To configure the port as an edge port set the port to True status e Admin Non Stp The port includes the STP mat
3. Meita ee iens i Fault Alarm Contacts 3 amp 4 The wire gauge for the terminal block should be in the range between 12 24 AWG MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 12 83 Cabling e Use four twisted pair Category 5e or above cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long e Fiber segment using single mode connector type must use 9 125 um single mode fiber cable User can connect two devices in the distance up to 30km e Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2km distances e Gigabit Copper SFP mini GBIC combo port The Industrial switch has the auto detected Giga port Gigabit Copper SFP combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable for the connection up to 1000Mbps The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting dual mode can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate S
4. ZP6 USSR Zone 5 WAST West Australian aJ hours 7 pm Standard i CCT China Coast USSR 8 hours 8 pm Zone 7 JST Japan Standard USSR NA 9 pm Zone 8 EAST East Australian Standard GST Guam Standard USSR Zone eM nouns on 9 IDLE International Date Line NZST New Zealand 12 hours Midnight Standard NZT New Zealand e SNTP Sever URL Set the SNTP server IP address You can assign a local network time server IP address or an internet time server IP address e Switch Timer When the switch has successfully connected to the SNTP server whose IP address was assigned in the column field of SNTP Server URL the current coordinated time is displayed here MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 32 83 Daylight Saving Period Set up the Daylight Saving beginning date time and Daylight Saving ending date time Please key in the value in the format of YYYYMMDD and HH MM leave a space between YYYYMMDD and HH MM o YYYYMMDD an eight digit year month day specification o HH MM a five digit including a colon mark hour minute specification For example key in 20070701 02 00 and 20071104 02 04 in the two column fields respectively to represent that DST begins at 2 00 a m on March 11 2007 and ends at 2 00 a m on November 4 2007 For non US and Europe
5. ONAN ARWN S and signs represent the polarity of the wires that make up each wire pair Before you power PD please check the RJ 45 connector pin assignment follow IEEE802 3af standard otherwise you may need to change one of the RJ 45 connector pin assignment attached with the UTP cable Appendix B Command Sets User EXEC Privileged EXEC Global configuration VLAN database Interface configuration lt fh UM System Commands Set Netstar Commands Level Description Show switch switch gt show show con Be ooo o configuration show terminal P Show console information switch tshow terminal write memory ethos user configuration switch write memory into permanent memory flash rom system name Configure system name _ switch config system name xxx System Name MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 71 83 Netstar Commands Level Description Example di aw System Location string Encre nnum x System Description description string XXX face been a System Contact window string S show system info how system information switch gt show system info ip address Configure the IP address _ switch config ip address Ip address Subnet mask of switch 192 168 16 1 255 255 255 0 Gateway 192 168 16 254 Bd AU tn RN
6. Port 03 100TX Down Enable g g 0 0 0 g 0 g Port 04 100TA DownEnable 0 g 0 0 0 g g Port 05 1Q00TX Down Enable 0 0 Port 06 100TX Down Enable g g 0 0 g g Port 7 1O00TX Up Enable 466 1132 g g g 137 1 Port 08 LOOT Down Enable 0 g 0 0 g 0 g Port 09 1GTX mGBIC Down Enable 0 g 0 0 0 g 0 g Fort 10 1GTX mGBEIC Down Enable 0 g g g Clear Help Port Statistics interface Port Control In Port control you can configure the settings of each port to control the connection parameters and the status of each port is listed beneath Port select the port that you want to configure State Current port status The port can be set to disable or enable mode If the port setting is disable then will not receive or transmit any packet MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 35 83 Negotiation Auto and Force Being set as Auto the speed and duplex mode are negotiated automatically When you set it as Force you have to set the speed and duplex mode manually Speed It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only Duplex It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this co
7. When the 802 1Q VLAN function is enabled all ports on the switch belong to default VLAN of VID 1 which means they logically are regarded as members of the same broadcast domain The valid VLAN ID is in the range of number between 1 and 4094 The amount of VLAN groups is up to 256 including default VLAN that cannot be deleted Each member port of 802 1Q is on either an Access Link VLAN tagged or a Trunk Link no VLAN tagged All frames on an Access Link carry no VLAN identification Conversely all frames on a Trunk Link are VLAN tagged Besides there is the third mode Hybrid A Hybrid Link can carry both VLAN tagged frames and untagged frames A single port is supposed to belong to one VLAN group except it is on a Trunk Hybrid Link The technique of 802 1Q tagging inserts a 4 byte tag including VLAN ID of the destination port PVID in the frame With the combination of Access Trunk Hybrid Links the communication across switches also can make the packet sent through tagged and untagged ports 802 1Q Configuration e Pull down the selection item and focus on 802 1Q then press Ay to set the VLAN Operation Mode in 802 1Q mode e Enable GVRP Protocol GVRP GARP VLAN Registration Protocol is a protocol that facilitates control of virtual local area networks VLANs within a larger network GVRP conforms to the IEEE 802 1Q specification which defines a method of tagging frames with VLAN configuration data This allows network devices
8. i i 4 1st Ring Port of X Ring TT R T 20ms 1st Ring Port of Dual Ring Forwarding Port Forwarding Port Ring Master MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 18 83 Console Management Connecting to the Console Port The supplied cable which one end is RS 232 connector and the other end is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of switch The connected terminal or PC must support the terminal emulation program 3 ems TIT T 7 To the console port of AH To PC or Terminal the Industrial Switch DB 9 pin Female Pin Assignment NC 1 OrangeWhite 2 J 290range 3 3 GreenWhite NC J4 Blue 5 S5 Blue White NC Green NC 7 Brown White NC 8 Brown NC 2 3 NC 5 NC NC NC MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 19 83 Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication par
9. FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 75 83 Netstar Commands Level Description vlan 8021q port Assign a hybrid link for switch vlan vlan 8021q port 3 PortNumber VLAN by port if the port hybrid link untag 4 tag 3 6 8 hybrid link untag belong to a trunk group jor UntaggedVID this command can t be switch vlan vlan 8021q port 3 tag applied hybrid link untag 5 tag 6 8 TaggedVID List vlan 8021q trunk Assign a access link for switch vlan vlan 8021q trunk 3 PortNumber VLAN by trunk group access link untag 33 Assign a trunk link for switch vlan vlan 8021q trunk 3 PortNumber VLAN by trunk group trunk link tag 2 3 6 99 trunk link tag Or TaggedVID List switch vlan vlan 8021q trunk 3 trunk link tag 3 20 Assign a hybrid link for switch vlan vlan 8021q trunk 3 PortNumber VLAN by trunk group hybrid link untag 4 tag 3 6 8 hybrid link untag Or UntaggedVID switch vlan ivlan 8021q trunk 3 tag hybrid link untag 5 tag 6 8 TaggedVID List show vlan GroupID V Show VLAN information switch vlan stshow vlan 23 Or show vlan no vlan group V Delete port base group ID switch vlan no vlan group 2 GroupID Netstar Commands Description Example h amp spanning tree enable Enable spanning tree switch config spanning tree enable spanning tree priority Configure spanning tree switch config spanning tree priority 0 61440 priorit
10. function of switch T switch RE re function of switch Bou 1 restart default G Restore to default switch config tdefault admin username Changes a login switch config admin username Username username XXXXXX maximum 10 words ae i EM m e Password maximum 10 words XXXXXX Kd eel ac RR information ahepserver enable G Enable DHCP Server switconfgjidhepserveremabie Disable DHCP Server FREE oe dhcpserver lowip Configure low IP address switch config dhcpserver lowip E EN E EN PT NN M High IP for IP pool 192 168 1 200 dhcpserver subnetmask Configure subnet mask switch config ztdhcpserver Subnet mack forbHcrdems subnetmask 293239 253 0 Gateway DHCP clients 192 168 1 254 dhcpserver dnsip Configure DNS IP for switch config dhcpserver dnsip hour 1 DNS IP dhcpserver leasetime Set static IP for DHCP switch config interface fastEthernet clients by port 2 Hours dhcpserver ipbinding switch config dhcpserver ipbinding 192 168 1 1 IP address u show dhcpserver Show configuration of switch show dhcpserver configuration DHCP server configuration show dhcpserver clients Show client entries of switch show dhcpserver clients DHCP server Show IP Binding switch show dhcpserver ip binding information of DHCP server function function MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www
11. 00 60 A7 12 34 56 78 dynamic DHCP 85762 DHCP Client Entries interface DHCP Server Port and IP Bindings Assign the dynamic IP address bound with the port to the connected client The user is allowed to fill each port column with one particular IP address When the device is connecting to the port and asks for IP assigning the system will assign the IP address bound with the port MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 25 83 DHCP Server Port and IP Binding System Configuration Client Entries Port and IP Binding l Port IP Port 01 0 0 0 0 Port 02 0 0 0 0 Port 03 0 0 0 0 Port 04 0 0 0 0 Port 05 0 0 0 0 Port 06 0 0 0 0 Port 07 0 0 0 0 Port 08 0 0 0 0 Port 09 0 0 0 0 Port 10 0 0 0 0 Apply Help Port and IP Bindings interface TFTP Update Firmware It provides the functions to allow the user to update the switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server e TFTP Server IP Address Fill in your TFTP server IP e Firmware File Name the name of firmware image e Click Apply TFTP Update Firmware Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 155 15 2 Firmware File Name limage bin Help Update Firmware interface TFTP Restore
12. 1 LEER IGMP Snooping Enable IGMP Query Enable Apply Help IGMP Configuration interface M Ring M Ring provides a faster redundant recovery than Spanning Tree topology The action is similar to STP or RSTP but the algorithms between them are not the same In the M Ring topology every switch should be enabled with M Ring function and two ports should be assigned as the member ports in the ring Only one switch in the M Ring group would be set as the master switch that one of its two member ports would be blocked called backup port and another port is called working port Other switches in the M Ring group are called working switches and their two member ports are called working ports When the failure of network connection occurs the backup port of the master switch Ring Master will automatically become a working port to recover from the failure The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the M Ring group If there are 2 or more switches in master mode the software will select the switch with lowest MAC address number as the ring master The M Ring master ring mode can be enabled by setting the M Ring configuration interface Also the user can identify whether the switch is the ring master by checking the R M LED indicator on the panel of the switch The system also supports the Couple Ring that can
13. Assign a trunk group with switch config taggregator group 1 1 GroupID Port list LACP active GroupID 1 4 4 lacp workp 2 Port list Member port list jor This parameter could be a switch config aggregator group 2 Workport port range ex 1 4 ora port 1 4 3 lacp workp 3 list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 74 83 Netstar Commands Level Description aggregator group Assign a static trunk group switch config aggregator group 1 2 GroupID Port list GroupID 1 4 4 nolacp nolacp Port list Member port list jor This parameter could be a switch config aggregator group 1 port range ex 1 4 or a port 3 1 2 nolacp list separate by a comma ex 2 3 6 Show the information of switch show aggregator 1 trunk group Or e eM aggregator 2 show aggregator Sieber aggregator 3 no aggregator lacp Disable the LACP function of switch config no aggreator lacp 1 GroupID trunk group no aggregator group Remove a trunk group switch config no aggreator group 2 GroupID VLAN Commands Set Netstar Commands Level Description vlan database ad Enter VLAN configure Example s database
14. Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Introduction Industrial Gigabit Ethernet Switch with M Ring 8x 10 100 1000Base T 2x 100 1000Base X SFP Combo Port meets the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Besides the industrial switch provides the PoE function for kinds of Powered Devices to receive power as well as data over the RJ 45 cable MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 3 83 Hardware features IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX IEEE802 3ab 1000Base T IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure Standard IEEE802 3ad Port trunk with LACP IEEE802 3af Power over Ethernet IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE 802 1x User Authentication Radius IEEE802 1ab LLDP Back plane Switching Fabric 5 6Gbps OMS Architecture Packet throughput ability Full Duplex 8 3Mpps 64bytes 14 880pps for Ethernet port Transfer Rate 148 800pp
15. GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 33 83 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off IP Security IP Security Mode Enable M Enable HTTP Server V Enable Telnet Server Security IP1 192 168 16 11 Security IP2 192 168 16 21 Security IP3 192 168 16 31 Security IP4 192 168 16 41 Security IP5 192 168 16 110 Security IP6 192 158 16 120 Security IP7 192 158 16 130 Security IPS 192 168 16 140 Security IPQ 192 168 16 210 Security IP10 152 168 16 220 Apply Help IP Security interface User Authentication Here you can change login user name and password for the management security issue e User name Key in the new user name The default is root e Password Key in the new password The default is root e Confirm password Re type the new password Appl e And then click Apply User Authentication User Name Wew Password es Confirm Password e User Authentication interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 34 83 Port Statistics The following chart provides the current statistic information which displays
16. accounts for receiving event alert Provides one relay output for port breakdown power fail Relay Alarm Alarm Relay current carry ability 1A 9 DC24V MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 6 83 1 Cold start 2 Link down SNMP Trap 3 Link up 4 Authorization fail 5 PD disconnect trap PoE port event jue Provides DHCP Client DHCP Server Port and IP Binding Provides DNS client feature and supports Primary and Secondary DNS server SNTP Supports SNTP to synchronize system clock in Internet Firmware Update Supports TFTP firmware update TFTP backup and restore Configuration Supports binary format configuration file for system quick Upload Download installation Each port allows importing 128bits of alphabetic string of word on SNMP and CLI interface Package Contents Please refer to the package content list below to verify them against the checklist e Industrial Gigabit Ethernet Switch with M Ring 8x 10 100 1000Base T 2x 100 1000Base X SFP Combo Port User manual x1 RJ 45 to DB9 Female cable x1 Pluggable Terminal Block x1 Mounting plate x2 Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Hardware description In this paragraph it will describe the Indust
17. com Manageable Gigabit Ethernet Switch with SFP User manual Page 17 83 Dual Homing Application Dual Homing function is to prevent the connection breaking from between M Ring group and upper level core switch Assign two ports to be the Dual Homing port that is the backup port in an M Ring group The Dual Homing function works only when the M Ring function is active Each M Ring group has only one Dual Homing port In Dual Homing application architecture the Rapid Spanning Tree protocol of the upper level switches need to be enabled Ethernet Switch Rapid Spanning Tree Protocol Ethernet Switch Perrys L eer mum emm dedu mes c ensca CUI e a a aa sa m CE E E N a Hot Standby Link M Ring Industrial Backup Path Switch Industrial E Switch IE Industrial Switch E Industrial Switch Switch Industrial Dual Ring Application Dual ring is the advanced function that supports backup connection for transmission redundant purpose While the connection fails the system will recover from failure within 20 milliseconds Apart from that Dual Ring only needs one unit and only the one located in the middle to be configured as the Ring Master switch to deploy the dual ring Dual Ring Backup Path gt gt ON v e i Blocking Blocking Port P 1 ort 2nd Ring Port of Dual Ring 2nd Ring Port of X Ring p Ring 1 Blocking Port s Blocking Port Ring2 2 E R T 20ms T E
18. connect 2 or more M Ring group for the redundant backup function Dual Homing function that can prevent connection lose between M Ring group and upper level core switch Apart from the advantages Dual Ring can handle 2 rings in the system and has the ability to recover from failure within 20 milliseconds e Enable Ring To enable the M Ring function tick the checkbox beside the Enable Ring string label If this checkbox is not ticked all the ring functions are unavailable o Enable Ring Master Tick the checkbox to enable this switch to be the ring master MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 58 83 o 1 amp 2 Ring Ports Pull down the selection menu to assign the ports as the member ports 1 Ring Port is the working port and 2 Ring Port is the backup port When 1 Ring Port fails the system will automatically upgrade the 2 Ring Port to be the working port e Enable Couple Ring To enable the couple ring function tick the checkbox beside the Enable Couple Ring string label o Couple Port Assign the member port which is connected to the other ring group o Control Port When the Enable Couple Ring checkbox is ticked you have to assign the control port to form a couple ring group between the two M rings e Enable Dual Homing Set up one of the ports on the switch to be the Dual Homing por
19. have to be the same e Untagged VID This column field is available when Link Type is set as Access Link and Hybrid Link Assign a number in the range between 1 an 4094 e Tagged VID This column field is available when Link Type is set as Trunk Link and Hybrid Link Assign a number in the range between 1 an 4094 Apply e Click to have the configuration take effect e You can see the link type untagged VID and tagged VID information of each port in the table below on the screen VLAN vontiguratien Port Part 1 Part 2 Part 3 Part 4 Part 5 Port 06 Port Port 08 Port 09 Port 10 VLAN Operation Mode 8n Iv Enable GVRP Protocol Management vlan ID lo 802 10 Configuration Port Link Type Group Configuration Untagged Vid Tagged Vid Fort 0i Access Link h Apply Help Link Type Access Link Access Link Trunk Link Hybrid Link Access Link Access Link Access Link Access Link Access Link Access Link Untagged Vid Tagged Vid z 3 i zd Dn 2 3 7 d E d 1 1 802 1Q VLAN interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 47 83 Group Configuration Edit the existing VLAN Group Select the VLAN group in the table list Edit e Click VLAN Configuration VLAN Operation Mode p0210 W Enable GVRP P
20. host v1 v2c 192 168 1 50 snmpv3 context name Configure the context switch config snmpv3 context name Context Name name Test snmpv3 user Configure the userprofile switch config snmpv3 user test01 User Name for SNMPV3 agent group G1 password AuthPW PrivPW group Privacy password could be Group Name empty password Authentication Password Privacy Password snmpv3 access context Configure the access table switch config snmpv3 access name Context Name of SNMPV3 agent context name Test group G1 group security level AuthPriv Group Name match rule Exact views V1 V1 V1 security level NoAuthNoPriv AuthNoPriv AuthPriv match rule Exact Prifix views Read View Name Write View Name Notify View Name snmpv3 mibview view Configure the mibview switch config snmpv3 mibview view View Name table of SNMPV3 agent V1 type Excluded sub oid 1 3 6 1 type Excluded Included sub oid OID show snmp P Show SNMP configuration switch show snmp Strings Community community strings publie o s carna strings Community community strings public Host address host 192 168 1 50 ser mamet onmes agents r econome snmpva user Test User Name SNMPv3 agent MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 79 83 Netstar Commands Leve
21. mode Vlanmode To set switch VLAN mode switch vlan vlanmode portbase portbase 802 1q gvrp or switch vian vlanmode 802 1q or switch vlan stvlanmode gvrp novan V jNoVLAN Switch vian no vlan Ported based VLAN configuration switch vlan vlan port based port PortNumbers Edd vlan GroupID oW vlan no vlan group GroupID vlan 8021q name GroupName vid VID vlan 8021q port PortNumber access link untag UntaggedVID vlan 8021q port PortNumber trunk link tag TaggedVID List grpname test grpid 2 port 2 4 grpname test grpid 2 port 2 3 4 M VLAN switch vlan show vlan 23 oo Delete ici sks base group ID switch vlan no vlan group 2 IEEE 802 1Q VLAN Change the name of vlan port based grpname V Add new port based i Group Name VALN i grpid or GroupID switch vlan vlan port based switch vlan vlan 8021q name test VLAN group if the group vid 22 didn t exist this command can t be applied Assign a access link for switch vlan vlan 8021q port 3 VLAN by port if the port access link untag 33 belong to a trunk group this command can t be applied Assign a trunk link for switch vlan vlan 8021q port 3 trunk VLAN by port if the port link tag 2 3 6 99 belong to a trunk group jor this command can t be switch vlan vlan 8021q port 3 trunk applied link tag 3 20 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0
22. of the two switches When disabled the trunk group is a static trunk group The advantage of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports but member ports won t know that they should be aggregated together to form a logic trunk group e Work ports This column field allows the user to type in the total number of active port up to four With LACP static trunk group e g you assign four ports to be the members of a trunk group whose work ports column field is set as two the exceed ports are standby redundant ports and can be aggregated if working ports fail If it is a static trunk group non LACP the number of work ports must equal the total number of group member ports e Select the ports to join the trunk group The system allows four ports maximum to be Add aggregated in a trunk group Click Add to add the port which is focused to the left Hemove field To remove unwanted ports select the port and click l e When LACP enabled you can configure LACP Active Passive status for each port on State Activity page Appl o lll Delete l Delete e Use to delete Trunk Group Select the Group ID and click MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 37 83 Port Trunk Aggregator Setting Aggregator Setting Aggregator Informa
23. offset of daylight switch config sntp daylight offset 3 Minute saving time if SNTP function is inactive this command can t be applied Le G sntp daylight period Start time End time Set SNTP server IP if SNTP switch config sntp ip 192 169 1 1 function is inactive this command can t be applied Set timezone index use switch config ztsntp timezone 22 show sntp timzezone command to get more information of index number sntp timezone Timezone Show SNTP information switch show sntp Show index number of switch show sntp timezone time zone list show sntp timezone Disable SNTP function switch config no sntp Disable daylight saving switch config zno sntp daylight time no sntp daylight MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 83 83 m ring Commands Set Netstar Commands Level Description Example O ring enable amp Enable Mring swtconfipiringenable G nableringmaster swithkonfifring master ring couplering G nablecouplering __ switch configy ring couplering G Enable dual homing ring ringport M E 1st 2nd Ring switch config tring ringport 7 8 1st Ring Port 2nd Ring Port S Penta Coupling Port pwiichiconfio ring couplingpor 1 ee massima cai Control Port ring homingp
24. the real time packet transfer status for each port The user might use the information to plan and implement the network or check and find the problem when the collision or heavy traffic occurs Port The port number Type Displays the current speed of connection to the port Link The status of linking Up or Down State It s set by Port Control When the state is disabled the port will not transmit or receive any packet Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 bytes oversize CRC Align errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving bad packets including undersize less than 64 bytes oversize CRC error fragments and jabbers via this port Tx Abort Packet The aborted packet while transmitting Packet Collision The counts of collision packet Packet Dropped The counts of dropped packet Rx Bcast Packet The counts of broadcast packet Rx Mcast Packet The counts of multicast packet l Clear Click button to clean all counts Port Statistics Tx Good Tx Bad Rx Good Rx Bad Tx Abort Packet Packet RX Bcast RX Mcast Port Type Link State Packet Packet Packet Packet Packet Collision Dropped Packet Packet Port 1 1O00TX Down Enable 0 g 0 0 0 0 Port 02 1O0O0TX DownEnable 0 g g 0 0 g 0
25. 3 function Context Table Configure SNMP v3 context table Assign the context name of context table Click Add to add context name Click Remove to remove unwanted context name User Profile Configure SNMP v3 user table e User ID Set up the user name e Authentication Password Set up the authentication password e Privacy Password Set up the private password Add e Click to add context name l Remove e Click to remove unwanted context name Group Table Configure SNMP v3 group table e Security Name User ID Assign the user name that you have set up in user table e Group Name Set up the group name Add e Click to add context name l Remove e Click to remove unwanted context name MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 53 83 SNMP SNMPv3 Configuration System Configuration Trap Configuration l SNMPv3 Configuration Context Table Context Name Apply User Table Current User Profiles New User Profile Remove Add none User ID Authentication Password Privacy Password Group Table Current Group content New Group Table Remove Add none Security Name User ID Group Name Access Table Current Access Tables New Access Table Remove Add none Context Prefix Group Name C NoAuthNoPriv AuthNoPr
26. Base TX connections or Gigabit Ethernet 10Base T 100Base TX 1000Base T connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the figures below for straight through and crossover cable schematic 10 100BASE TX Pin outs With10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data e RJ 45 Pin Assignments and signs represent the polarity of the wires that make up each wire pair The table below shows the 10 100BASE TX MDI and MDI X port pin outs PinMDEX Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD DL a Transmit Data minus TD Receive Data minus RD 10 100Base TX Cable Schematic The following two figures show the 10 100Base TX cable schematic Switch Router or PC 3 TD4 5 RD 6 TD 6 RD kD 4 1 TD 2 RD 4 2 TD Straight through cable schematic MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Switch 3 TD 6 TD RD 2 RD 10 100 1000Base TX Pin outs Cross over cable schematic 3 6 2 Switch ID TD RD RD T
27. Configuration You can restore a previous backup configuration from the TFTP server to recover the settings Before doing that you must locate the image file on the TFTP server first and the switch will download back the flash image e TFTP Server IP Address Fill in your TFTP server IP e Restore File Name Fill in the correct restore file name e Click Apply TFTP Restore Configuration Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 165 16 2 Restore File Name data hin Help Restore Configuration interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 26 83 TFTP Backup Configuration You can back up the current configuration from flash ROM to the TFTP server for the purpose of recovering the configuration later It helps you to avoid wasting time on configuring the settings by backing up the configuration e TFTP Server IP Address Fill in your TFTP server IP e Backup File Name Fill the file name e Click Apply TFTP Backup Configuration Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address Backup File Name data bir Cini Hata Backup Configuration interface System Event Log Syslog Configuration This page allows the user to decide whether to send the system event log and sel
28. FF Port 09 N A 1GTX mGBIC Down Enable Auto 1G Full N A Enable N A OFF Port 10 N A 1GTX mGBIC Down Enable Auto 1G Full N A Enable N A OFF Port Control interface Port Trunk Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any one single port or network cable Link Aggregation Control Protocol LACP which is a protocol running on layer 2 provides a standardized means in accordance with IEEE 802 3ad to bundle several physical ports together to form a single logical channel All the ports within the logical channel or so called logical aggregator work at the same connection speed and LACP operation requires full duplex mode MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 36 83 Aggregator setting e System Priority A value which is used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP peer of the trunk group e Group ID There are 13 trunk groups to be selected Assign the Group ID to the trunk group e LACP When enabled the trunk group is using LACP A port which joins an LACP trunk group has to make an agreement with its member ports first Please notice that a trunk group including member ports split between two switches has to enable the LACP function
29. FP transceiver to plug into the slots Then use proper multi mode or single mode fiber according to the transceiver With fiber optic it transmits at speed up to 1000 Mbps and you can prevent noise interference from the system The SFP Copper Combo port can t both work at the same time The SFP port has the higher priority than copper port if you insert the 1000M SFP transceiver which has connected to the remote device via fiber cable into the SFP port the connection of the accompanying copper port will link down If you insert the 100M SFP transceiver into the SFP port even without a fiber connection to the remote the connection of the accompanying copper port will link down immediately To connect the transceiver and LC cable please follow the steps shown below First insert the transceiver into the SFP slot Notice that the triangle mark is the bottom of the slot Triangle Mark Transceiver to the SFP slot MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 13 83 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connec
30. Green Full duplex Collision Amber SFP port LNK ACT Green 1000T LNK ACT Green 1000M Green External Power Supply DC 48V Redundant power DC 48V and Power Suppl PP y connective removable terminal block for master and slave power Power Consumption 116Watts Full load Operating Humidity 5 to 95 Non condensing Operating Standard 10 C 60 C Temperature Wide Operating Temperature 40 C 75 C P30 69mm W x 132mm D x 176mm CM Installation DIN rail and wall mount ear FCC Class A CE EN61000 4 2 CE EN61000 4 3 CE EN 61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Stability Testing oo Free fall IEC60068 2 27 Shock IEC60068 2 6 Software features RFC 1215 Trap RFC1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 RFC 1757 RSTP MIB Private MIB LLDP MIB Port Based VLAN VLAN IEEE 802 1Q Tag VLAN 256 entries VLAN ID Up to 4K VLAN ID can be assigned from 1 to 4096 GVRP 256 Groups Port Trunk with LACP Supports LLDP allowing switch to advertise its identification and capability on the LAN Peer eee IEEE802 1d spanning tree P g IEEE802 1w rapid spanning tree MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Storage 40 C 85 C Temperature LACP Port Trunk 4 Trunk groups Maximum 4 trunk members Man
31. MICROSENS Expert Line Managed Industrial Switch with M Ring Function and PoE 8x 10 100 Base TX 2x 10 100 1000Base T 100 1000 Base X SFP Ports User Manual General Ethernet is an international standard that has been proven in millions of applications worldwide ensuring the compatibility of components from various vendors The IP protocol has already left the in house environment and is using also in harsh environments industrial solutions What is more the integration of the industrial network with the data network is easily done without protocol conversion The new Managed Expert Line Industrial Switches meet the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance The devices are very compact and include 8 Port Gigabit Ethernet switches 10 Port Gigabit Ethernet switches 18 Port Gigabit Ethernet switches For particularly demanding uses the industrial switches are designed in a suitably robust construction with an integrated clamping device for direct assembly on 35 mm DIN rails This new Expert Line Switches are providing also extensive management function and offering the possibility to build fiber optic m rings for redundancy The ultra fast protection mechanism provides short reaction time for missing critical and fail sensitive applications Gigabit Ethernet Switch MICROSENS GmbH a
32. P assign range is from 192 168 1 100 192 168 1 200 Therefore 192 168 1 200 is the High IP address e Subnet Mask The dynamic IP assign range subnet mask e Gateway The gateway in your network e DNS Domain Name Server IP Address in your network MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 24 83 e Lease Time sec It is the time period that system will reset the dynamic IP assignment to ensure the dynamic IP won t have been occupied for a long time otherwise the server won t know that the dynamic IP is idle And then click Apply DHCP Server System Configuration System Configuration Client Entries Part and IP Bindina DHCP Server Disable v Low IP Address 192 168 16 100 High IP Address 102 168 16 200 Subnet Mask 255 255 2550 Gateway 192 168 16 254 DNS 0 0 0 0 Lease Time sec 96400 anny Helo DHCP Server Configuration interface DHCP Client Client Entries When the DHCP server function is enabled the system will collect the DHCP client information including the assigned IP address the MAC address of the client device the IP assigning type status and lease time DHCP Server Client Entries System Configuration Port and IP Binding IP addr Client ID Type Status Lease 192 168 16 101 00 60 A7 45 67 89 00 dynamic DHCP 85383 192 168 168 100
33. P of TFTP server and the file name of image upgrade flash upgrade fw Upgrade firmware by TFTP switch config tupgrade and need to specify the IP of flash upgrade fw TFTP server and the file name of image SystemLog SMTP and Event Commands Set Netstar Commands Level Description systemlog ip Set System log server IP switch config t systemlog ip IP address address 192 168 1 100 systemlog mode Specified the log mode switch config t systemlog mode both client server both show systemlog E Displays system log Switch gt show systemlog show systemlog Show system log client amp switch show systemlog server information no systemlog G Disable systemlog functon switch config no systemlog smtp enable G Enable SMTP function switch config smtp enable IP address 192 168 1 5 authentication account account password password Index Email address Address Alert test com SMTP Disable SMTP function switch config no smtp event authentication failure Systemlog SMTP Both event ring topology change Systemlog SMTP Both event systemlog Link UP Link Down Both Set Authentication failure switch config event authentication event type failure both Set M ring topology switch config event ring topology changed event type change both Set port event for system switch config interface fastethernet 3 switch config if event systemlog both event device cold start Set cold start
34. Page 55 83 QoS Configuration Qos Policy Use an 8 4 2 1 weighted fair queuing scheme C Use a strict priority scheme Priority Type Disable Apply Help Port based Priority Port 01 Port 02 Port 03 Port 04 Port 05 Port 06 Port 07 Port 03 Port 09 Port 10 Li eg LOWES Lowes Lowest Lowest Lowest Lowest Lowest Lowest Lowest Apply Help cos Priority 0 1 2 3 4 6 i Lowest Lowest Lowest r Lowest Lowest Lowest Lowest Lowest Apply Help TOS Priority 0 Lowest mes mes IE E IE Es EE Priority 8 14 Lowest Lowest IE IE IE mes Lowest IET Priority 16 17 22 Lowest Eum ET E IE E Lowes EE Priority 24 Lowest fave mes ies IE mes IE IE Priority 32 Lowest ioves E r iones E IE E EZ Priority 40 Lowest E mes E E mes E IE Priority 48 3 Lowest r E m Priority 56 i 58 59 60 61 62 J 63 Lowest Lowest Lowest Lowest Lowest Lowest Lowest Lowest Apply Help QoS Configuration interface Port Base Priority Configure the priority level for each port With the drop down selection item of Priority Type above being selected as Port based this control item will then be available to set the queuing policy for each port e Port x Each port has 4 priority leve
35. ageable Gigabit Ethernet Switch with SFP User manual Page 5 83 Supports M ring Dual Homing Couple Ring and Dual Ring Topology Provides redundant backup feature and the recovery time below 20ms The quality of service determined by port Tag and IPv4 Type of STEELS SAGE service IPvA IPv6 Different Service Supports IEEE802 1p class of service per port provides 4 priority queues Class of Service Supports 100 entries of MAC address for static MAC and another 100 Port Security for MAC filter Supports 3 mirroring types RX TX and Both packet Supports IGMP snooping v1 v2 256 multicast groups and IGMP query Supports 10 IP addresses that have permission to access the switch Eosecurity management and to prevent unauthorized intruder Login Security Supports IEEE802 1X Authentication RADIUS Support ingress packet filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 100K 102400Kbps 10 100 100K 256000Kbps 1000 Ingress filter packet type combination rules are Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The packet filter rate can be set from 100K 102400Kbps 10 100 100K 256000Kbps 1000 Bandwidth Control Supports Flow Control for Full duplex and Back Pressure for Half duplex System Log Supports System log record and remote system log server SMTP Supports SMTP Server and 6 e mail
36. aits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 o Hello Time 1 10 The time that controls switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 o Forward Delay Time 4 30 The number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening to STP states to the forwarding state Enter a value between 4 through 30 Follow the rule to configure the MAX Age Hello Time and Forward Delay Time 2 x Forward Delay Time value 1 gt Max Age value gt 2 x Hello Time value 1 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 49 83 RSTP System Configuration System Configuration Port Configuration RSTP Mode Enable Priority 0 61440 22768 Max Age 6 40 o0 Hello Time 1 10 Fra Forward Delay Time 4 30 Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or zn ta 2 Hello Time 1 Apply Help Root Bridge Information Bridge ID 0060A7123456 Root Priority 32768 Root Port Root Root Path Cost 0 Max Age 20 Hello Time 2 _ Forward Delay 15
37. ameters to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None COM Properties x Fort settings Bits per second EET NN Data bits Bo Parity Nons e Stop bits h xj Elow control Nae re Advanced Restore Defaults The settings of communication parameters After finishing the parameter settings click OK When the blank screen shows up press Enter key to bring out the login prompt Key in the root default value for the both User name and Password use Enter key to switch then press Enter key and the Main Menu of console management appears Please see the figure for login screen as below User Mame root Password REEL Conslole login interface CLI Management The system supports a command line interface management CLl After you have logged in the system by typing in user name and password you will see a command prompt To enter CLI management interface enter enable command MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 20 83 switch gt e switch CLI command interface The following table lists the CLI commands and description Commands Level The user commands available at the user level are a subset of those available at th
38. an countries specify the amount of time for day light savings Please key in the valid figure in the range of minute between 0 and 720 which means you can set the offset up to 12 hours Appl aia V SNTP Configuration SNTP Client Enable Daylight Saving Time Enable UTC Timezone GMT 08 00 Taipel SNTP Server URL 70 158 30 201 Switch Timer Daylight Saving Period 20070311 02 0 20071104 02 0 Daylight Saving Offset mins Apply Help SNTP Configuration interface IP Security IP security function allows the user to assign 10 specific IP addresses that have permission to manage the switch through the http and telnet services for the securing switch management The purpose of giving the limited IP addresses permission is to allow only the authorized personnel device can do the management task on the switch IP Security Mode When this option is enabled the Enable HTTP Server and Enable Telnet Server Check boxes will then be available Enable HTTP Server When this check box is checked the IP addresses among Security IP1 IP10 will be allowed to access via HTTP service Enable Telnet Server When checked the IP addresses among Security IP1 IP10 will be allowed to access via Telnet service Security IP 1 10 Assign up to 10 specific IP addresses Only these 10 IP address can access and manage the switch through the Web browser Apply And then click button to apply the configuration MICROSENS
39. bled the specified port works without complying with 802 1x protocol Appl c DAR 802 1x Radius Port Configuration System Configuration Port Configuration l Misc Configuration Port State Port 01 4 Port 02 Port 03 Authorize Port 04 Port os v Reject Accept Authorize WeiDisable Port Authorization Port State Port 01 Disable Port 02 Disable Port 03 Disable Port 04 Disable Port 05 Disable Port 06 Disable Port 07 Disable Port 08 Disable Port 09 Disable Port 10 Disable 802 1x Per Port Setting interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 61 83 Misc Configuration e Quiet Period Set the period during which the port doesn t try to acquire a supplicant TX Period Set the period the port wait for retransmit next EAPOL PDU during an authentication session e Supplicant Timeout Set the period of time the switch waits for a supplicant response to an EAP request e Server Timeout Set the period of time the switch waits for a server response to an authentication request e Max Requests Set the number of authentication that must time out before authentication fails and the authentication session ends e Reauth period Set the period of time after which clients connected must be re authenticated Appl o aa APY 802 1x Radiu
40. bo w M Ring Managed Switch and the installation points to be attended to it Installation Steps Unpack the Industrial switch packing Check if the DIN Rail is screwed on the Industrial switch or not If not please refer to DIN Rail Mounting section for DIN Rail installation If user wants to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights Prepare the twisted pair straight through Category 5e above cable for Ethernet connection Insert one side of RJ 45 cable into the Industrial switch Ethernet port RJ 45 port and another side of RJ 45 cable to the network device s Ethernet port RJ 45 port e g Switch PC or Server The UTP port RJ 45 LED on the industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication When all connections are set and LED lights all show in normal the installation is complete DIN Rail Mounting Please follow the steps below to hang the industrial switch Backside Pull
41. ch config 8021x misc timeout global servertimeout 20 configuration command to set the server timeout Use the 802 1x misc max switch config t 8021x misc request global maxrequest 3 configuration command to set the MAX requests Use the 802 1x misc switch config 8021x misc reauth period global reauthperiod 3000 configuration command to set the reauth period Use the 802 1x port state switch config interface fastethernet interface configuration 3 command to set the state switch config if 48021x portstate of the selected port accept Displays a summary of the switch gt show 8021x 802 1x properties and also the port sates Disable 802 1x function switch config tno 8021x 8021x misc servertimeout sec 8021x misc maxrequest number 8021x misc reauthperiod sec 8021x portstate disable reject accept authorize show 8021x no 8021x MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 81 83 TFTP Commands Set Netstar Commands Level Description Defaults Example backup flash backup cfg Save configuration to TFTP switch config backup and need to specify the IP of flash backup_cfg TFTP server and the file name of image restore flash restore cfg Get configuration from TFTP switch config restore server and need to specify flash restore cfg the I
42. down the drop down menu bar Enable LACP Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically Port Trunk Aggregator Setting Aggregator Setting Aggregator Information State Activity System Priority F Group ID Trunk 1 Select Lacp Enable gt Work Ports Apply Delete Help Notice The trunk function do not support GVRP and M Ring Switch 1 configuration interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 39 83 Port Trunk Aggregator Information Aggregator Setting State Activity zt Q060A7234567 PortNo Key Priority Active PortNo Key Priority selected 8 513 1 selected Static Trunking Group Group Key 2 Port Member Port 01 Port 02 Aggregation Information of Switch 1 Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches configured Switch 2 configuration Port Trunk Aggregator Setting Aggregator Setting 1 Aggregator Information 1 State Activity System Priority n Group ID Trunk 1 _ Select Lacp T Work Ports 2 cdd Remove So Apply D
43. dress to the switch e DHCP Client Enable or disable the DHCP client function When DHCP client function is enabled the industrial switch will be assigned an IP address from the network DHCP server The default IP address will be replaced with an IP address which is assigned by the DHCP server After user click Apply button a pop up dialog show up It is to inform the user that when the DHCP client is enabled the current IP will lose and user should find the new IP on the DHCP server e IP Address Assign the IP address that the network is using If DHCP client function is enabled then user needn t assign the IP address manually Instead the network DHCP server will assign the IP address for the industrial switch and display it in this column The default IP is 192 168 16 1 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 23 83 Subnet Mask Assign the subnet mask of the IP address If DHCP client function is disabled the user has to assign the subnet mask in this column field e Gateway Assign the network gateway for the switch If DHCP client function is disabled the user has to assign the gateway in this column field The default gateway is 192 168 16 254 e DNS1 Assign the primary DNS IP address e DNS2 Assign the secondary DNS IP address And then click Apply IP Configuration DHCP Cli
44. e privileged level Use this mode to e Perform basic tests e Displays system information The privileged command is Enter the enable advance mode Privileged ere Enter disable to Privileged this mode to command while in switch EXEC Near EXEC mode exit e Displays advance function status e Save configures Begin a session with TEN Enter logout or NEDERES your switch quit Enter the configure To exit to Global command while in switch privileged EXEC Configuration privileged EXEC contig mode enter mode exit or end Use this mode to configure parameters that apply to your switch as a whole Er ie vial To exit to user database command switch Use this mode to configure VLAN database ais A EXEC mode de while in privileged vlan st VLAN specific parameters enter exit EXEC mode To exit to global configuration mode enter exit To exist to privileged EXEC mode or end Enter the interface command with a switch specific interface config while in global if configuration mode Use this mode to configure parameters for the switch and Ethernet ports Interface configuration MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 21 83 Web Based Management This section introduces the configuration and functions of the Web Based management About Web ba
45. e proper UTP cable to construct user network Please check that is using the right cable use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps connections or 100 Category 5e 6 cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet e Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutionsems e f the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance e f the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit Please check user system s Ethernet devices configuration or status MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 67 83 Appendix A RJ 45 Pin Assignment RJ 45 Pin Assignments The UTP STP ports will automatically sense for Fast Ethernet 10Base T 100
46. ect the mode which the system event log will be sent to client only server only or both client and server What kind of event log will be issued to the client server depends on the selection on the Event Configuration tab There are five types of event Device Cold Start Device Warm Start Authentication Failure M Ring Topology Change and Port Event available to be issued as the event log e Syslog Client Mode Select the system log mode Client Only Server Only or Both Client Only means the system event log will only be sent to this interface of the switch but on the other hand Server Only means the system log will only be sent to the remote system log server with its IP assigned If the mode is set in Both the system event log will be sent to the remote server and this interface e System Log Server IP Address When the Syslog Mode item is set as Server Only Both the user has to assign the system log server IP address to which the log will be sent e Click Reload to refresh the events log e Click Clear to clear all current events log e After configuring click Apply MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 27 83 System Event Log Syslog Configuration Syslog Configuration l SMTP Configuration Event Configuration Syslog Client Mode Both Syslog Ser
47. elete Help Notice The trunk function do not support GVRP and M Ring Switch 2 configuration interface Set System Priority of the trunk group The default is 1 Select a trunk group ID by pull down the drop down menu bar Enable LACP a ee run Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 40 83 Port Trunk Aggregator Information Aggregator Setting State Activity Groupi Actor Partner Priority 1 1 MAC 0060A7123456 QUA 723455 7 PortNo Key Priority Active PortNo Key Priority E 513 1 selected 5 5131 E 5131 selected 3 513 1 Aggregation Information of Switch 2 Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches configured State Activity Having set up the LACP aggregator on the tab of Aggregator Setting you can configure the state activity for the members of the LACP trunk group You can tick or cancel the checkbox beside the state display When you remove the tick mark to the port and click Apply the port state activity will change to Passive e Active The port automatically sends LACP protocol packets e Passive The p
48. em serverport Use the 802 1x system switch config 8021x system port ID server port global serverport 1812 configuration command to change the radius server port MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 80 83 Netstar Commands Level Description 8021x system accountport Use the 802 1x system switch config 8021x system port ID account port global accountport 1813 configuration command to change the accounting port Use the 802 1x system switch config 8021x system share key global sharedkey 123456 configuration command to change the shared key value Use the 802 1x system switch config 8021x system nasid nasid global test1 configuration command to change the NAS ID Use the 802 1x misc quiet switch config 8021x misc period global quietperiod 10 configuration command to specify the quiet period value of the switch Use the 802 1x misc TX switch config 8021x misc txperiod 5 period global configuration command to set the TX period 8021x misc supptimeout Use the 802 1x misc supp switch config 8021x misc sec timeout global supptimeout 20 8021x system sharedkey ID 8021x system nasid words 8021x misc quietperiod sec 8021x misc txperiod sec configuration command to set the supplicant timeout Use the 802 1x misc server swit
49. ent Disable IP Address Subnet Mask 255 255 255 0 Gateway DNS1 0000 0 Apply Help IP configuration interface DHCP Server System configuration DHCP is the abbreviation of Dynamic Host Configuration Protocol that is a protocol for assigning dynamic IP addresses to devices on a network With dynamic addressing a device can have a different IP address every time it connects to the network In some systems the device s IP address can even change while it is still connected DHCP also supports a mix of static and dynamic IP addresses Dynamic addressing simplifies network administration because the software keeps track of IP addresses rather than requiring an administrator to manage the task This means that a new computer can be added to a network without the hassle of manually assigning it a unique IP address The system provides the DHCP server function Having enabled the DHCP server function the switch system will be configured as a DHCP server e DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network e Low IP Address the dynamic IP assign range Low IP address is the beginning of the dynamic IP assigns range For example dynamic IP assign range is from 192 168 1 100 192 168 1 200 192 168 1 100 will be the Low IP address e High IP Address the dynamic IP assign range High IP address is the end of the dynamic IP assigns range For example dynamic I
50. event type switch config tevent device cold Systemlog SMTP Both start both MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 82 83 Netstar Commands Level Description Example event smtp Set port event for SMTP switch config tinterface fastethernet Link UP Link Down Both 3 switch config if tevent smtp both show event Show event selection switch show event Sp type start failure failure event type authentication failure change changed event type topology change no event systemlog Disable port event for switch config interface fastethernet system log 3 switch config if no event systemlog no event smtp Disable port event for switch config interface fastethernet SMTP 3 switch config if no event smtp oe onn S server information SNTP Commands Set Netstar Commands Level Description Example sntp enable LT Enable SNTP function switch config tsntp enable sntp daylight Enable daylight saving switch config sntp daylight time if SNTP function is inactive this command can t be applied Set period of daylight switch config sntp daylight period saving time if SNTP 20060101 01 01 20060202 01 01 function is inactive this command can t be applied Parameter format yyyymmdd hh mm sntp daylight offset Set
51. ex htm Coo Bf Password NT reae reae rbanotenrt aure serbade ba Pha koe enrt ano eenu paseo Login screen MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 22 83 System Information User can assign the system name description location and contact personnel to identify the switch The version table below is a read only field to show the basic information of the switch e System Name Assign the name of switch The maximum length is 64 bytes e System Description Displays the description of switch e System Location Assign the switch physical location The maximum length is 64 bytes e System Contact Enter the name of contact person or organization e Firmware Version Displays the switch s firmware version e Kernel Version Displays the kernel software version e MAC Address Displays the unique hardware address assigned by manufacturer default System Information System Name System Description 8 10 100TX 2 10 100 1000T Mini GBIC Combo w 8 PoE Injec System Location P System Contact D OE Apply Help Firmware Version v1 11 Kernel Version v1 58 MAC Address OO60A 7123456 System information interface IP Configuration The switch is a network device which needs to be assigned an IP address for being identified on the network Users have to decide a means of assigning IP ad
52. ferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 44 83 VLAN Configuration VLAN Operation Mode Port Based Enable GVRP Protocol Management vlan ID fo Apply Group Name VLAN 1 VLAN ID 78 Po rt 1 Part nz Part 3 Part na Add Remove Apply Help Enter the group name and VLAN ID Add the selected port number into the right field to group these members to be a VLAN group or remove any of them listed in the right field from the VLAN _ Apply e And then click to have the configuration take effect You will see the VLAN list displays VLAN Configuration VLAN Operation Mode Port Based Enable GVRP Protocol Management wlan ID o VLAM 1 i Add Edit Delete Help VLAN Port Based Edit Delete interface Delete e Use to delete the VLAN Edit Use Edt to modify group name VLAN ID or add remove the members of the existing VLAN group MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 45 83 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 802 1Q VLAN Virtual Local Area Network VLAN can be implemented on the switch to logically create different broadcast domain
53. he following figure shows the 10 100 1000 Ethernet RJ 45 pin outs Pin Label TPO TPO TP TPs TP2 rea TP3 TP3 b oL MB e a zu un 10 100 1000Base TX Cable Schematic Swich gg ma f OF b TPO TPO TP1a TP1 TP24 TP2 TP34 TP3 Router oc FC TP14 TP1 TPO TPO a 4n pb T tet M co TP TP3 TP24 TP2 Straight through cables schematic Page 68 83 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 69 83 Cwrinh Dwitch TPO UT TP z TRO 2 TRO 3 TP1 3 TPi amp TPI amp TP 4 TP2 X IF2 5 TP2 5 TP2 7 IP3e 4 e 7 TRS a TP3 a TF3 Cross over cables schematic RJ 45 Pin Assignment of PoE With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data pins 4 5 7 and 8 are used for power supplying Pin out of Cisco non 802 3af standard PD MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 70 83 Pin out of PoE Midspan Hub Switch Signal Name RX RX TX VCC VCC TX VCC VCC Pin 1 2 3 4 5 6 7 8 Pin out of PoE Endspan Hub Switch Signal Name TX VCC TX VCC TX VCC TX VCC
54. hematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation Appl e Click ed MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual RSTP Port Configuration System Configuration Path Cost Port 02 Priority 1 200000000 0 240 Port Configuration Admin P2P Admin Edge Admin Non Stp Page 50 83 Port 03 200001 128 Auto true false Port o4 Port 05 priority must be a multiple of 16 Apply Help RSTP Port Status Path Port OperOper Stp Port cost Priority P2P Edge Neighbor at Role Port 01 200000 128 True True False Disabled Disabled Port 02 200000 128 True True False Disabled Disabled Port 03 200000 128 True True False Disabled Disabled Port 04 200000 128 True True False Disabled Disabled Port 05 200000 128 True True False Disabled Disabled Port 06 200000 128 True True False Disabled Disabled Port 07 20000 128 False True False Forwarding Designated Port 08 200000 128 j True True False Disabled Disabled Port 09 20000 128 True True False Disabled Disabled Port 10 20000 128 j True True False Disabled Disabled RSTP Port Configuration interface SNMP Configuration Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers worksta
55. hernet Switch with SFP User manual Page 43 83 VLAN Configuration VLAN Operation Mode Disable Enable GYRP Pratacal Management vlan ID VLA NOT ENABLE VLAN Configuration interface VLAN configuration Port based VLAN A port based VLAN basically consists of its members ports which means the VLAN is created by grouping the selected ports This method provides the convenience for users to configure a simple VLAN easily without complicated steps Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored The port based VLAN function allows the user to create separate VLANSs to limit the unnecessary packet flooding however for the purpose of sharing resource a single port called a common port can belongs to different VLANs which all the member devices ports in different VLANs have the permission to access the common port while they still cannot communicate with each other in different VLANs VLAN Configuration VLAN Operation Mode Port Based v Enable GYVEP Protocol Management Wlan ID Edit Delete Help VLAN Port Based interface Appl Pull down the selection item and focus on Port Based then press vpy to set the VLAN Operation Mode in Port Based mode Add Click EL to add a new VLAN group The maximum VLAN groups are up to 64 MICROSENS GmbH amp Co KG Kue
56. it Set interface output switch config interface fastEthernet bandwidth Rate Range is 2 from 100 kbps to 102400 switch config if bandwidth out 100 kbps or to 256000 kbps for giga ports and zero means no limit show bandwidth Show interfaces switch config interface fastEthernet bandwidth control 2 switch config if show bandwidth state Use the state interface switch config interface fastEthernet Enable Disable configuration command 2 to specify the state mode switch config if state Disable of operation for Ethernet ports Use the disable form of this command to disable the port show interface show interface switch config interface fastEthernet configuration configuration status 2 switch config if show interface configuration show interface status show interface actual switch config interface fastEthernet status 2 switch config if show interface status show interface accounting show interface statistic switch config interface fastEthernet counter 2 switch config if show interface accounting no accounting Clear interface switch config interface fastEthernet accounting information 2 switch config if no accounting Trunk Commands Set Netstar Commands Level Description aggregator priority Set port group system priority Exame aor priority 3 priority 22 1 65535 aggregator activityport Set activity port switch config aggregator Group ID activityport 2 Port Numbers aggregator group
57. it value which is under 15 4 Watts e Mode Displays the operating mode of the port e Current mA Displays the operating current of the port e Voltage V Displays the operating voltage of the port e Power mW Displays the power consumption of the port e Determined Class Displays the PD s class _ Apply e And then click to carry into effect Factory Default Reset switch to default configuration Click Reset to reset all configurations to the default value MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 66 83 Factory Default M Keep current IP address setting v Keep current username amp password Reset Help Factory Default interface Save Configuration Save all configurations that you have made in the system To ensure the all configuration will be saved Click Save Flash to save the all configuration to the flash memory Save Configuration Save Configuration interface System Reboot Reboot the switch in software reset Click Reboot to reboot the system System Reboot Please click Reboot button to restart switch device Reboot System Reboot interface Trouble shooting e Verify that is using the right power cord adapter DC 12 48V please don t use the power adapter with DC output higher than 48V or it will burn this converter down e Select th
58. iv Security Level C AuthPriv Context Match Rule Exact Prefix Read View Name Write View Name Notify View Name MIBView Table Current MIBTables New MIBView Table Remove Add none View Name SubOid Tree Type Excluded Included Help Note Any modification of SNMPv3 tables might cause MIB accessing rejection Please take notice of the causality between the tables before you modify these tables SNMP V3 configuration interface Access Table Configure SNMP v3 access table e Context Prefix Set up the context name e Group Name Set up the group name e Security Level Select the access level e Context Match Rule Select the context match rule e Read View Name Set up the read view e Write View Name Set up the write view e Notify View Name Set up the notify view Add e Click to add context name l Remove e Click to remove unwanted context name MIBview Table Configure MIB view table e ViewName Set up the name MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 54 83 e Sub Oid Tree Fill the Sub OID e Type Select the type exclude or included Add e Click to add context name l Remove e Click to remove unwanted context name QoS Configuration Quality of Service QoS is the ability to provide different priority to different applications u
59. ively by setting the trigger condition e System event selection There are 4 event types Device Cold Start Device Warm Start Authentication Failure and M ring Topology Change The checkboxes are not available for ticking unless the Syslog Client Mode on the Syslog Configuration tab and the E mail Alert on the SMTP Configuration tab are enabled first o Device cold start When the device executes cold start action the system will issue a log event email alert to the system log SMTP server respectively o Device warm start When the device executes warm start the system will issue a log event email alert to the system log SMTP server respectively o Authentication Failure When the SNMP authentication fails the system will issue a log event email alert to the system log SMTP server respectively o M ring topology change When the M ring topology has changed the system will issue a log event email alert to the system log SMTP server respectively e Port event selection Also before the drop down menu items are available the Syslog Client Mode selection item on the Syslog Configuration tab and the E mail Alert selection item on the SMTP Configuration tab must be enabled first Those drop down menu items have 3 selections Link UP Link Down and Link UP amp Link Down Disable means no event will be sent to the system log SMTP server MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www micro
60. l Description no snmpv3 access context Remove specified access switch config no snmpv3 access name Context Name table of SNMPv3 agent context name Test group G1 security group level AuthPr Group Name iv match rule Exact views V1 V1 V1 security level NoAuthNoPriv AuthNoPriv AuthPriv match rule Exact Prifix views Read View Name Write View Name Notify View Name no snmpv3 mibview view Remove specified switch config no snmpv3 mibview View Name mibview table of SNMPV3 view V1 type Excluded sub oid 1 3 6 1 type agent Excluded Included sub oid OID Port Mirroring Commands Set Netstar Commands Level Description Example a monitor function Set TX destination port of switch config monitor tx REN dn NR B mmu information Show port monitor switch config interface fastEthernet information 2 switch config if show monitor Disable source port of switch config interface fastEthernet monitor function 2 switch config if no monitor 802 1x Commands Set Netstar Commands Level Description Example Z 8021x enable Use the 802 1x global switch config 8021x enable configuration command to enable 802 1x protocols 8021x system radiusip Use the 802 1x system switch config 8021x system IP address radius IP global radiusip 192 168 1 1 configuration command to change the radius server IP 8021x syst
61. lia anes table static table static filter table filter Remove an entry of MAC switch config interface fastEthernet address table of interface 2 static switch config if no mac address table static hwaddr 000012345678 no mac address table filter Remove an entry of MAC switch config no mac address table hwaddr address table filter filter hwaddr 000012348678 MAC MAC address table SNMP Commands Set Netstar Commands Description Example snmp system name Set SNMP agent system __ switch config snmp system name System Name name I2switch snmp system location Set SNMP agent system __ switch config snmp system location location lab System Location MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 78 83 Netstar Commands Level Description Example CIC ENERO Bald nad System Contact contact where cae S end ee a viv2cilv3 v1 v2cv3 SNMP v1v2cv3 snmp community strings Add SNMP community switch config snmp community Community string strings public right rw right RO RW snmp server host Configure SNMP server switch config snmp server host IP address host information and 192 168 1 50 community public community community string trap version v1 Community string remove trap version Switch config no snmp server
62. ls High Middle Low and Lowest to be chosen Appl tice AY MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 56 83 COS Configuration Set up the COS priority level With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port e COS priority Set up the COS priority level 0 7 with 4 egress queues High Middle Low Lowest Appl o aa APY TOS Configuration Set up the TOS priority With the drop down selection item of Priority Type above being selected as TOS only TOS first this control item will then be available to set the queuing policy for each port e TOS priority the system provides 0 63 TOS priority level Each level has 4 types of priority egress queues high middle low and lowest The default value is Lowest priority for each level When the IP packet is received the system will check the TOS level value in the IP packet that has received For example user set the TOS level 25 as high the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority Appl cia APY IGMP Configuration The Internet Group Management Protocol IGMP is an inter
63. lumn is read only Flow Control Whether or not the receiving node sends feedback to the sending node is determined by this item When enabled once the device exceeds the input data rate of another device the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time When disabled the receiving device will drop the packet if too much to process Security When the Security selection is set as On any access from the device which connects to this port will be blocked unless the MAC address of the device is included in the static MAC address table See the segment of MAC Address Table Static MAC Addresses Appl clic APY Port Control Negotiation Speed Duplex Flow Control Security Full Enable Off Port State Enable Auto r Apply Help Speed Duplex Flow Control Port Group ID Type Link State Negotiation TRE RE Security Port O1 N A 100TX Down Enable Auto 100 Full M A Enable N A OFF Port 02 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 03 N A 100TX Down Enable Auta 100 Full N A EnableN A OFF Port O4 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 05 N A 100Tx Down Enable Auto 100 Full N A Enable N A OFF Fort 06 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 07 N A 100TX Up Enable Auto 100 Full 100 HalfEnable OFF OFF Port 08 N A 1O00TX Down Enable Auto 100 Full N A Enable N A O
64. microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 16 83 M Ring Application The industrial switch supports the M Ring protocol that can help the network system to recovery from network connection failure within 20ms or less and make the network system more reliable The M Ring algorithm is similar to spanning tree protocol STP algorithm but its recovery time is faster than STP The following figure is a sample M Ring application Data collect server ment Interface Industrial Switch ES A H M Ring Backup path Field Management M Ring Group Industrial Switch Programmable logic controller Distribute 1 O control system Serial Device Server Field Automatic device Field Automatic device Field Automatic device Coupling Ring Application In the network there may have more than one M Ring group Using the coupling ring function can connect each M Ring for redundant backup It can ensure the transmissions between two ring groups not to fail The following figure is a sample of coupling ring application Coupling Ring Backup Path Coupling Port switch 1 Coupling Port switch 3 Control Port A a Backup path s N Control Port switch 2 switch 4 M Ring Group A Coupling Port Backup path MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens
65. microsens com show dhcpserver ip binding no dhcpserver security enable Manageable Gigabit Ethernet Switch with SFP User manual Page 72 83 security http security telnet security ip Index 1 10 IP Address etstar Commands show security security telnet Description Example Enable IP security of HTTP switch config security http server Enable IP security of switch config security telnet telnet server Set the IP security list switch config security ip 1 192 168 1 55 Show the information of switch show security IP security pew eee no security http Bd i all Port Commands Set Netstar Commands interface fastEthernet Portid function HTTP server telnet server Description Example Choose the port for switch config interface fastEthernet modification 2 Use the duplex switch config interface fastEthernet configuration command 2 to specify the duplex switch config if duplex full mode of operation for Fast Ethernet Use the speed switch config interface fastEthernet configuration command 2 to specify the speed mode switch config if tspeed 100 of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga port no flowcontrol Disable flow control of switch config if no flowcontrol interface security enable Enable security of switch config interface fastEthernet interface 2 switch c
66. move Add public RO String PO private RW CRO RW Agent Mode Current Mode C SNMP V1 V2C only SNMP v1 v2c only l C SNMP V3 only C SNMP Vi1 V2C V3 Change Help SNMP System Configuration interface Trap Configuration A trap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version e IP Address Enter the IP address of trap manager e Community Enter the community string e Trap Version Select the SNMP trap version type v1 or v2c Add e Click e To remove the community string select the community string listed in the current l Remove managers field and click MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 52 83 SNMP Trap Configuration System Configuration l Trap Configuration SHMPv3 Configuration Trap Managers Current Managers Mew Manager Remove Add 132 169 16 21 TrapHnst v1 IP Address 152 158 18 23 192 168 16 22 IrapHastz v2 Community TrapHost3 Trap version Help Trap Managers interface 1 C yec SNMPV3 Configuration Configure the SNMP V
67. mp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 2 83 The contents of this manual are based on the table below listing firmware version software kernel version and hardware version If the switch functions are different from the description of the manual please contact the local sale dealer for more information T diis Hardware version FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e
68. n of advancing clocks so that afternoons have more daylight and mornings have less Typically clocks are adjusted forward one hour near the start of spring and are adjusted backward in autumn e SNTP Client Enable or disable SNTP function to get the time from the SNTP server e Daylight Saving Time This is used as a control switch to enable disable daylight saving period and daylight saving offset Users can configure Daylight Saving Period and Daylight Saving Offset in a certain period time and offset time while there is no need to enable daylight saving function Afterwards users can just set this item as enable without assign Daylight Saving Period and Daylight Saving Offset again e UTC Timezone Set the switch location time zone The following table lists the different location time zone for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC AST Atlantic Standard ROUES e EDT Eastern Daylight EST Eastern Standard Shou Jam CDT Central Daylight MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 31 83 MDT Mountain Daylight PDT Pacific Daylight PST Pacific Standard A ac ADT Alaskan Daylight ALA Alaskan Standard CET Central European FWT French Winter MET Middle European xau MEWT Middle European Winter SWT Swedish Winter EET Eastern European
69. nal protocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message as follows A message sent from the querier IGMP router or switch asking for a Query response from each host belonging to the multicast group A message sent by a host to the querier to indicate that the host Report wants to be or is a member of a given group indicated in the report message Leave A message sent by a host to the querier to indicate that the host has Group quit being a member of a specific multicast group The switch supports IP multicast You can enable IGMP protocol via setting IGMP configuration page to see the IGMP snooping information IP multicast addresses are in the range of 224 0 0 0 through 239 255 255 255 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 57 83 e IGMP Protocol Enable or disable the IGMP protocol e IGMP Query enable or disable the IGMP query function The IGMP query information will be displayed in IGMP status section Appl cia AY IGMP Configuration IP Address VLAN ID Member Part 259 250 200 2035 TERELTE 224 000 000 251 1 oe ee ape k ok eg ouo
70. ned in the IEEE 802 1AB it is an emerging standard which provides a solution for the configuration issues caused by expanding LANs LLDP specifically defines a standard method for Ethernet network devices such as switches routers and wireless LAN access points to advertise information about themselves to other nodes on the network and store the information they discover LLDP runs on all 802 media The protocol runs over the data link layer only allowing two systems running different network layer protocols to learn about each other e LLDP Protocol Pull down the selection menu to disable or enable LLDP function e LLDP Interval Set the interval of advertising the switch s information to other nodes Appl ice PV LLDP Configuration LLDP Protocol Disable LLOP Interval 30 sec Apply Help LLDP Interface Security In this section you can configure 802 1x and MAC address table 802 1X Radius Configuration 802 1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority like the user name and password that are verified by an authentication server such as RADIUS server System Configuration After enabling the IEEE 802 1X function you can configure the parameters of this function e IEEE 802 1x Protocol Enable or disable 802 1x protocol e Radius Server IP Set the Radius Server IP address e Server Port Set the UDP destination por
71. nt D Static Address Count 3 Clear MAC Table All MAC Address interface MAC Address Table Multicast Filtering Multicasts are similar to broadcasts they are sent to all end stations on a LAN or VLAN Multicast filtering is the function which end stations can receive the multicast traffic if the connected ports had been included in the specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to the registered end stations e IP Address Assign a multicast group IP address in the range of 224 0 0 0 239 255 255 255 e Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address A l e Click Ad to append a new filter of multicast to the field or select the filter in the Delete field and click to remove it MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 64 83 MAC Address Table Multicast Filtering Static MAC Addresses MAC Filtering All Mac Addresses Multicast Filtering 239 000 000 100 jore 239 000 001 100 qe upon 239 000 002 100 Topupu e Ep IP Address 238 0 3 100 Part 0i Porto F Part a3 Port o4 Member Ports Portas C Port a6 M Part a7 I Part a8 Port og D Part 10 Add Delete Help Multicast Fil
72. nt which provides the link path for one or more VLAN aware devices switches A Trunk Port connected to the trunk link has an understanding of tagged frame which is used for the communication among VLANs across switches Which frames of the specified VIDs will be forwarded depends on the values filled in the Tagged VID column field Please insert a MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 46 83 comma between two VIDs Note 1 A trunk port doesn t insert tag into an untagged frame and therefore the untagged VID column field is not available 2 It s not necessary to type 1 in the tagged VID The trunk port will forward the frames of VLAN 1 3 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports have to be the same o Hybrid Link A segment which consists of Access and Trunk links The hybrid port has both the features of access and trunk ports A hybrid port has a PVID belonging to a particular VLAN and it also forwards the specified tagged frames for the purpose of VLAN communication across switches Note 1 It s not necessary to type 1 in the tagged VID The hybrid port will forward the frames of VLAN 1 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports
73. onfig if security enable speed 10 100 1000 auto no security Disable security of switch config interface fastEthernet interface 2 switch config if no security bandwidth type all Set interface ingress limit switch config interface fastEthernet frame type to accept all 2 frame switch config if bandwidth type all 2 bandwidth type broadcast Set interface ingress limit switch config interface fastEthernet multicast flooded unicast frame type to accept broadcast multicast and switch config if bandwidth type flooded unicast frame broadcast multicast flooded unicast Set interface ingress limit switch config interface fastEthernet frame type to accept broadcast and multicast switch config if bandwidth type frame broadcast multicast bandwidth type broadcast multicast bandwidth type broadcast only Set interface ingress limit switch config tinterface fastEthernet frame type to only accept 2 broadcast frame switch config if bandwidth type broadcast only MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 73 83 Netstar Commands Level Description Set interface input switch config interface fastEthernet bandwidth Rate Range is 2 from 100 kbps to 102400 switch config if bandwidth in 100 kbps or to 256000 kbps for giga ports and zero means no lim
74. ort Configure Dual Homing _ switch config ring homingport 3 s vm pene ring M Ring G Disable M ring switch config no ring G Disable ring master switch config no ring master Coupling Port Disable couple ring switch config no ring couplering Disable dual homing switch config no ring dualhoming Order Information 2x SFP slot 10x RJ 45 2x Power 1x Console Industrial Gigabit Ethernet Switch with M Ring MS651220PM 48 8x 10 100Base TX PoE 2x 100 1000Base X SFP Combo Port MICROSENS reserves the right to make any changes without further notice to any product to improve reliability function or design MICROSENS does not assume any liability arising out of the application or use of any product 5008 md fr MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com
75. ort does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device roup A link having either two active LACP nodes or one active node can perform dynamic LACP trunk A link having two passive LACP nodes will not perform dynamic LACP trunk because both ports are waiting for an LACP protocol packet from the opposite device Port Trunk State Activity Aggregator Setting Aggregator Information i 5tate Activity Port LACP State Activity PortLAcP State Activity 1 N A 2 NA 3 M Active 4 N A 5 Iv Active 5 N A N A 8 N A a N A 10 N A Apply Help Port Trunk State Activity interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 41 83 Port Mirroring The Port mirroring is a method for monitoring traffic in switched networks Traffic through ports can be monitored by one specific port That means traffic goes in or out monitored source ports will be duplicated into mirror destination port e Destination Port There is only one port can be selected to be destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only User can connect mirror port to LAN analyzer or Netxray e Source Port The p
76. orts that user wants to monitor All monitored port traffic will be copied to mirror destination port User can select multiple source ports by checking the RX or TX check boxes to be monitored Appl e And then click iiid button Port Mirroring Destination Port Source Port RX TX RX TX Port 01 e C Iv Iv Port 02 Hm e Iv Iv Port 03 6 C Iv O Port 04 C C O Iv Port 05 C Iv O Port 06 G C Iv Iv Port 07 e C Iv Iv Port 08 6 C Iv E Port 09 C C E Iv Port 10 ud C Iv O Apply _Help Port Trunk Port Mirroring interface Rate Limiting You can set up every port s bandwidth rate and frame limitation type e Ingress Limit Frame type Select the frame type that you want to filter The frame types have 4 options for selecting All Broadcast Multicast Flooded Unicast Broadcast Multicast and Broadcast only Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports the type of AIl MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 42 83 Rate Limiting Ingress Limit Frame Type Ingress Egress Port 1 All E kbps o kbps Port 02 I Se aE Ee SLT OTT OR ANNUS D kbp E D kbps Port 04 Al llo kbpsl0 kbps Port s Al v o wbps D kbps Port 06 Al vx o kbpslo kbps Port 0z Al
77. ount and password for authentication when this switch logs in to the SMTP server e Mail Account Set up the email account e g johnadmin to receive the email alert It must be an existing email account on the mail server e Password The email account password e Confirm Password reconfirm the password e Rcpt e mail Address 1 6 you can assign up to 6 e mail accounts also to receive the alert Appl e Click PN MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 28 83 System Event Log SMTP Configuration Syslog Configuration l SMTP Configuration Event Configuration E mail Alert Enable SMTP Server IP Address f H2 158 15 5 Sender switch10 162123 com i Auth entication Mail Account johnadmin Password eer Confirm Password em 0004 Rcpte mail Address 1 supemisomil23 com Rcpt e mail Address 2 T Rcpt e mail Address 3 EN Repte mailAddress4 Rcpte mailAddress5 Rcpt e mail Address 6 MEN Help SMTP Configuration interface System Event Log Event Configuration Having ticked the Syslog SMTP checkboxes the event log email alert will be sent to the system log server and the SMTP server respectively Also Port event log alert link up link down and both can be sent to the system log server SMTP server respect
78. power on Green Off No power The industrial switch is the master of M Ring rou Green group Off The industrial switch is not a ring master in M Ring group Power 1 is active Green ff Power 1 is inactive Power 2 is active Green Off Power 2 is inactive n Power or port failure FAULT Off No failure A network device is detected 7 gt D gt i gt it Green Upper LED The port is transmitting or receiving packets from the TX device Green Lower 1000M LED The SFP port is linking Green Blinking P9 P10 RJ Ul Link Active The port is transmitting or receiving packets from Blinks the TX device No device attached A network device is detected Green P9 P10 SFP WR The port is transmitting or receiving packets from Pis the TX device No device attached The port is operating in full duplex mode Amber P1 P8 Blinking Collision of Packets occurs The port is in half duplex mode or no device is Off attached A powered device is connected utilizing Power GIREN Ethernet on the port FWD P1 P8 Green ttl No device is connected or power forwarding fails MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 9 83 Hardware Installation In this paragraph we will describe how to install the 8 10 100 1000T 2 10 100 1000T 100 1000 SFP Com
79. rial switch s hardware spec port cabling information and wiring installation Physical Dimension Industrial Gigabit Ethernet Switch with M Ring 8x 10 100 1000Base T 2x 100 1000Base X SFP Combo Port dimension is 69 x 132 x 176 mm w xd x h Front Panel Here is the front panel of the Industrial Gigabit Ethernet Switch with M Ring 8x 10 100 1000Base T 2x 100 1000Base X SFP Combo Port shown as below MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 7 83 NN 10 100 10008 T lt E d o z 9 Front Panel of the industrial switch Bottom View The bottom panel of the the Industrial Gigabit Ethernet Switch with M Ring 8x 10 100 1000Base T 2x 100 1000Base X SFP Combo Port has one terminal block connector in which has two DC power inputs Top Panel of the industrial switch LED Indicators There are diagnostic LED indicators located on the front panel of the industrial switch They provide real time information of system and optional status The following table provides description of the LED status and their meanings for the switch MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 8 83 The switch unit is
80. riority cos Configure COS Priority switch config qos priority cos 0 Priority lowest low middl middle iori Configure TOS Priority switch config qos priority tos 3 high Priority lowest low middl elhigh MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 77 83 Netstar Commands Level Description Example Displays the information Switch show qos of QoS configuration Se a cae Disable QoS function switch config no qos IGMP Commands Set Netstar Commands Level Description Example ud E dtd NN function Igmp query auto Set IGMP query to auto switch config zzlgmp query auto er S metes erem mamme Igmp query force Set IGMP query to force switch config zzlgmp query force memet moe NEE remate ment cuanto e IGMP configuration remm eMe snoopingenties nn IGMP snooping entries UL adl abaci function Mv IT Mac Filter Table Commands Set Netstar Commands Level Description mac address table static Configure MAC address switch config interface fastEthernet table of interface static 2 switch config if mac address table static hwaddr 000012345678 mac address table filter Configure MAC address switch config itmac address table hwaddr table filter filter hwaddr 000012348678 MAC sici
81. rotocol Management vlan ID E Apply 502 10 Configuration D Group Configuration Delete Group Configuration interface You can Change the VLAN group name and VLAN ID VLAN Configuration VLAN Operation Mode s021Q9 M Enable GYRP Protocol Management Wlan ID lo Apply 502 10 Configuration Group Contiguration Group Name VLAN_3 YLA ID 3 Apply Group Configuration interface MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 48 83 Rapid Spanning Tree The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol RSTP System Configuration User can view spanning tree information about the Root Bridge Appl User can modify RSTP state After modification click dad button o RSTP mode User must enable or disable RSTP function before configure the related parameters o Priority 0 61440 A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root The value must be a multiple of 4096 according to the protocol standard rule o Max Age 6 40 The number of seconds a bridge w
82. s Misc Configuration System Configuration Port Configuration l Misc Configuration Quiet Period lo Tx Period Bo Supplicant Timeout 30 Server Timeout n Max Requests D J Reauth Period 3600 Apply Help 802 1x Misc Configuration interface MAC Address Table Use the MAC address table to ensure the port security Static MAC Address You can add a static MAC address it remains in the switch s address table regardless of whether the device is physically connected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again You can add modify delete a static MAC address Add the Static MAC Address You can add static MAC address in the switch MAC table here e MAC Address Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity e Port No Pull down the selection menu to select the port number MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 62 83 Add e Click e f you want to delete the MAC address from filtering table select the MAC address and l Delete Click MAC Address Table Static MAC Addresses MAC Filtering All Mac Addresses Multicast Filtering AABBCCDDEEFF FFEEDDCCBBAA Part 1
83. s e Firmware Version This column shows the PoE chip s firmware version e Port Knockoff Disabled Power Management state where one or more PDs have been powered down so that a higher priority PD may be powered up and yet not exceed the maximum total power available for PDs e AC Disconnect Tick this checkbox to monitor the AC impedance on the port terminals and removes power when the impedance rises above a certain value for a certain period for details see the IEEE 802 3af specification e Capacitive Detection If the port and capacitive detection are enabled the capacitances state reads in the voltage result from the constant current This is then subtracted from the pre capacitance voltage to get a charge rate If this charge rate is within the window of the PD signatures the device is considered to be discovered e Start Showing with a tick symbol the system initializes and resets successfully _ Apply e And then click to carry into effect e Port The index of PoE ports e Enable State Check it to enable the PoE function to the port e Power Limit From Check it to decide the power limit method o Classification When this check box is ticked the system will limit the power supply to the powered device in accordance with the related class e Legacy Check it to support the legacy power devices e Priority Pull down the selection menu item to choose the priority of power supplying e Port Limit 15400 mW User can key in the power lim
84. s for Fast Ethernet port 1 488 000pps for Gigabit Fiber Ethernet port Cmemmm oem OOS Comm os o 10 100TX 8 x RJ 45 10 100 1000T Mini GBIC Combo 2 x RJ 45 2 x 100 1000 SFP sockets RS 232 connector RJ 45 type 10Base T 2 pair UTP STP Cat 3 4 5 5E cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E cable NETWOrK cae EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Distance Multi mode 0 to 5 km 1300 nm 50 125 um 800 MHz km 0 to 4 km 1300 nm 62 5 125 um 500 MHz km Single mode 0 to 40 km 1310 nm 9 125 um 3 5 PS nm km 0 to 80 km 1550 nm 9 125 um 19 PS nm km Optical Fiber Min TX Output Multi mode 20 dBm Single mode 0 to 40 km 5 dBm 0 to 80 km 5 dBm Max TX Output Multi mode 14 dBm Single mode 0 to 40 km 0 dBm 0 to 80 km 0 dBm Sensitivity 36 to 32 dBm Single mode 34 to 30 dBm Multi mode RJ 45 port 1 8 support IEEE 802 3af End point Alternative A mode Per port provides 15 4W ability Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com PoE pin assignment Manageable Gigabit Ethernet Switch with SFP User manual Page 4 83 Per unit Power Green Power 1 Green Power 2 Green Fault Red Master Green FWD Green 8 port 10 100 Link Activity
85. sed Management On CPU board of the switch there is an embedded HTML web site residing in flash memory which offers advanced management features and allow users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen Preparing for Web Management Before using web management install the industrial switch on the network and make sure that any one of the PCs on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password are as follows e IP Address 192 168 16 1 e Subnet Mask 255 255 255 0 e Default Gateway 192 168 16 254 e User Name root e Password root System Login 1 Launch the Internet Explorer on the PC 2 Key in http the IP address of the switch and then Press Enter File Edit View Favorites Tools Help x Bach gt x E Pi j Search SY Favorites al ci p Address E http 192 168 16 1 The login screen will appear right after 4 Key in the user name and password The default user name and password are the same as root 5 Press Enter or OK and then the home screen of the Web based management appears as below gt ind
86. sens com Manageable Gigabit Ethernet Switch with SFP User manual Page 29 83 o Link UP The system will only issue a log message when the link up event of the port occurs o Link Down The system will only issue a log message when the link down event of port occurs o Link UP amp Link Down The system will issue a log message at the time when port connection is link up and link down System Event Log Event Configuration Syslog Configuration SMTP Configuration Event Configuration System event selection Event Type Syslog SMTP Device cold start O Iv Device warm start Iv O Authentication failure O Iw X Ring topology change Iv a Port event selection Port Syslog SMTP Port 01 Disable xf Disable H Port 02 Di EU Disable W Port 03 Disable Port 04 Disable rj Port 05 Disable xf Disable I Port 06 Disable Disable H Port 07 Disable xf Disabe Port 08 Disable xf Disable ej Port 09 Disable Disable Port 10 Disable gt Disable H Help Event Configuration interface Fault Relay Alarm The Fault Relay Alarm function provides the Power Failure and Port Link Down Broken detection With both power input 1 and power input 2 installed and the check boxes of power 1 power 2 ticked the FAULT LED indicator will then be possible to light up when any one of the power failures occurs As for the Port Link Down Broken detection the FAULT LED indicator will light up when the port failure occurs certainly the check bo
87. sers or data flows or to guarantee a certain level of performance to a data flow QoS guarantees are important if the network capacity is insufficient especially for real time streaming multimedia applications such as voice over IP or Video Teleconferencing since these often require fixed bit rate and are delay sensitive and in networks where the capacity is a limited resource for example in cellular data communication In the absence of network congestion QoS mechanisms are not required QoS Policy and Priority Type e Qos Policy select the Qos policy rule o Using the 8 4 2 1 weight fair queue scheme The switch will follow 8 4 2 1 rate to process priority queue from High to lowest queue For example when the system processes 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time in accordance with the 8 4 2 1 policy rule o Use the strict priority scheme Always higher queue will be process first except higher queue is empty e Priority Type there are 5 priority type selections available Disable means no priority type is selected e Port base the port priority will follow the Port base that you have assigned High middle low or lowest Appl e Click 285 MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual
88. t For a switch there is only one Dual Homing port Dual Homing function works only when the M Ring function enabled e Enable Dual Ring When this check box is ticked the Enable Ring Master check box will then also be enabled by the system which means this equipment is assigned as the Ring Master The Dual Ring differs from the Couple Ring in that it only needs a unit to form a redundant linking system of two rings _ Apply e And then click to apply the configuration M Ring Configuration W Enable Ring W Enable Ring Master 1st Ring Port Port D1 FORWARDING 2nd Ring Port Port o2 LINK OO VT Enable Couple Ring Couple Port Port 03 LINED Control Port Port 04 LINKO Yf Enable Dual Homing Homing Port Port 05 LINK DOWN W Enable Dual Ring 1st Ring Port Port D7 LINK OO VT 2nd Ring Port Port og LINK OO VT This switch is Ring Master Apply Help M ring Interface When the M Ring function enable user must disable the RSTP The M Ring function and RSTP function cannot exist in a switch at the same time MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 59 83 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off LLDP Configuration Link Layer Discovery Protocol LLDP is defi
89. t when selecting an interface to place into the forwarding state stp path priority Use the spanning tree port switch config interface fastEthernet Port Priority priority interface configuration 2 command to configure a port switch config if stp path priority priority that 128 is used when two switches tie for position as the root switch stp admin Autrruaee Autrruaee Admin P2P of STP priority on switch config stinterface fastEthernet this interface 2 switch config if stp admin p2p Auto Admin Sd of STP priority on switch config interface fastEthernet mune switch config if stp admin edge True Admin NonSTP of STP priority on this interface stp admin fated o fated o stp admin non stp True False switch config interface fastEthernet 2 switch config if stp admin non stp False show aoe a summary of the switch gt show spanning tree aoe tree states s Mil Disable spanning tree switch config no spanning tree QOS Commands Set Netstar Commands Level Description Example qos policy Select QOS policy switch config qos policy weighted weighted fair strict scheduling fair qos prioritytype Setting of QOS priority switch config tqos prioritytype port based cos only tos type only cos first tos first qos priority portbased Configure Port based switch config qos priority portbased Port Priority 1 low lowest low middle high qos p
90. t for authentication requests to the specified Radius Server e Accounting Port Set the UDP destination port for accounting requests to the specified Radius Server e Shared Key Set an encryption key for using during authentication sessions with the specified radius server This key must match the encryption key used on the Radius Server e NAS Identifier Set the identifier for the radius client MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 60 83 Appl e Click 28 802 1x Radius System Configuration System Configuration Port Configuration Misc Configuration 807 1 Protocol Enable Radius Server IP 192 168 16 237 Server Port 1812 Accounting Port 1813 Shared Key i2345678 NAS Identifier M amp S L2 SWITCH Apply Help 802 1x System Configuration interface 802 1x Port Configuration You can configure 802 1x authentication state for each port The State provides Disable Accept Reject and Authorize e Reject The specified port is required to be held in the unauthorized state e Accept The specified port is required to be held in the Authorized state e Authorized The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server e Disable When disa
91. tering interface Power over Ethernet This segment shows the Power over Ethernet function Power over Ethernet Maximum Power Available 200 Ww Actual Power Consumption 0 W System Power Limit 200 w Main Supply Voltage 480 dV Firmware Version 2 03 Port Knockoff Disabled AC Disconnect v Capacitive Detection Start fr Apply Power Limit Enable Power Limit From Mode Current Voltage Power Determined Port tate Classfication 93CY Priority Sea mA V mw Class 1 FE m tw 15400 Detecting 0 0 0 0 0 15 4W 2 R a r flow 15400 Detecting 0 0 0 0 0 15 4W 3 FE E C ow 15400 Detecting 0 0 0 0 0 15 4W a F a I tow 15400 Detecting 0 0 0 0 0 15 4W 5 F E tow 15400 Detecting o 0 0 0 0 15 4W 6 F C low 15400 Null 0 0 0 0 0 15 4W 7 F fi C ow 15400 Detecting 0 0 0 0 0 15 4W 8 F B tow 15400 Detecting 0 0 0 0 0 15 4W Apply PoE Status e Maximum Power Available Displays the maximum power supply in Watt e Actual Power Consumption This column shows the real time total power consumption MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 65 83 e System Power Limit User can modify the value to this column field to limit the total output power for the system e Main Supply Voltage This column shows the output voltage of the system for PoE port
92. tion State Activity System Priority pe Group ID Trunk i Select Lacp Enable Work Ports fa Remove gt gt Apply Delete Help Notice The trunk function do not support GVRP and X Ring Port Trunk Aggregator Setting interface Aggregator Information LACP disable Port Trunk Aggregator Setting Aggregator Setting l Aggregator Infarmatian State Activity System Priority 1 Group ID Trunk 2 Select Lacp sable Work Ports E lt lt Add Remove Apply Delete Help Notice The trunk function do not support GVRP and M Ring Assigning 2 ports to a trunk group with LACP disabled Port Trunk Aggregator Information Aggregator Setting Aggregator Information State Activity Static Trunking Group Group Key 1 Port Member 12 Static Trunking Group information MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 38 83 Group Key Displays the trunk group ID Port Member Displays the members of this static trunk group LACP enable Having set up the aggregator setting with LACP enabled you will see the trunking group information between two switches on the tab of Aggregator Information Switch 1 configuration 1 2 3 4 Set System Priority of the trunk group The default is 1 Select a trunk group ID by pull
93. tions routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP System Configuration e Community Strings You can define a new community string set or remove unwanted community string o String Fill the name of string o RO Read only Enables requests accompanied by this string to display MIB object information o RW Read write Enables requests accompanied by this string to display MIB object information and to set MIB objects Add Click o To remove the community string select the community string that you defined Remove l l l before and click The strings of Public RO and Private RW are default strings You can remove them but after resetting the switch to default the two strings show up again MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 51 83 Change Agent Mode Select the SNMP version that you want to use it And then click to switch to the selected SNMP version mode SNMP System Configuration System Configuration Trap Configuration SNMPv3 Configuration Community Strings Current Strings New Community String Re
94. to dynamically exchange VLAN configuration information with other devices For example having enabled GVRP on two switches they are able to automatically exchange the information of their VLAN database Therefore the user doesn t need to manually configure whether the link is trunk or hybrid the packets belonging to the same VLAN can communicate across switches Tick this checkbox to enable GVRP protocol This checkbox is available while the VLAN Operation Mode is in 802 1Q mode e Management VLAN ID Only when the VLAN members whose Untagged VID PVID equals to the value in this column will have the permission to access the switch The default value is 0 that means this limit is not enabled all members in different VLANs can access this switch e Select the port you want to configure e Link Type There are 3 types of link type o Access Link A segment which provides the link path for one or more stations to the VLAN aware device An Access Port untagged port connected to the access link has an untagged VID also called PVID After an untagged frame gets into the access port the switch will insert a four byte tag in the frame The contents of the last 12 bit of the tag is untagged VID When this frame is sent out through any of the access port of the same PVID the switch will remove the tag from the frame to recover it to what it was Those ports of the same untagged VID are regarded as the same VLAN group members o Trunk Link A segme
95. to release MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 10 83 e First insert the top of DIN Rail into the track e Then lightly push the DIN Rail into the track e Check if the DIN Rail is tightened on the track or not e To remove the industrial switch from the track pull down the release plate as shown with the first picture pull to release MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 11 83 Wiring the Power Inputs Please follow the steps below to insert the power wire V V V V Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing The wire gauge for the terminal block should be in the range between 12 24 AWG Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Industrial Switch
96. tor MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 14 83 Second push down the metal loop and pull the transceiver out by the plastic handle Pull out from the transceiver Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application A sample application of the industrial switch is shown as below Data collect server Industrial Industrial Mises NN Switch Switch am Field Management Distribute O Programmable control system logic controller Serial Device Server Field Automatic device Field Automatic device Field Automatic device MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 15 83 The illustration below shows an example of power over Ethernet application Non PoE Devices IEEE 802 3af Compliant Powered Devices Non PoE Non PoE VoIP Phone Access Point VoIP Phone IP Camera Wireless AP Power Ethernet Power Cable Cable Cable Ethernet Cable Splitter Splitter PoE Industrial Switch Uplink via UTP STP Uplink via Fiber MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www
97. v j o kbps kbps Portos v o Wbeps O kbps Port 09 C D kb ps D kb ps Port 10 C D kbps D kbps Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit Help Rate Limiting interface 1 4 4 e All the ports support port ingress and egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate as 1Mbps ingress rate as 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate o Ingress Enter the port effective ingress rate The default value is 0 o Egress Enter the port effective egress rate The default value is 0 _ Apply e And then click to apply the settings VLAN configuration A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which would allow you to isolate network traffic so only the members of the VLAN will receive traffic from the same VLAN members Basically creating a VLAN from a switch is logically equivalent to reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The industrial switch supports port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Et
98. ver IP Address 192 168 16 200 Apply 3 Jan 1 00 02 53 System Log Server IP 192 168 16 200 2 Jan 1 00 02 53 System Log Enable 1 Jan 1 00 02 18 Clear System Log Table Reload Clear Help Syslog Configuration interface System Event Log SMITP Configuration Simple Mail Transfer Protocol SMTP is the standard for email transmissions across the network You can configure the SMTP server IP mail subject sender mail account password and the recipient email addresses which the e mail alert will send to There are also five types of event Device Cold Start Device Warm Start Authentication Failure M Ring Topology Change and Port Event available to be issued as the e mail alert Besides this function provides the authentication mechanism including an authentication step through which the client effectively logs in to the SMTP server during the process of sending e mail alert e Email Alert With this function being enabled the user is allowed to configure the detail settings for sending the e mail alert to the SMTP server when the events occur e SMTP Server IP set up the mail server IP address when Email Alert enabled this function will then be available e Sender key in a complete email address e g switch101 123 com to identify where the event log comes from e Authentication Having ticked this checkbox the mail account password and confirm password column fields will then show up Configure the email acc
99. x beside the port must be ticked first Please refer to the segment of Wiring the Fault Alarm Contact for the failure detection e Power Failure Tick the check box to enable the function of lighting up the FAULT LED on the panel when power fails e Port Link Down Broken Tick the check box to enable the function of lighting up FAULT LED on the panel when Ports states are link down or broken MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 30 83 Fault Relay Alarm Power Failure M Power 1 M Power 2 Port Link Down Broken C Port 1 C Fort 2 Port 3 Port 4 Port 5 M Port 6 C Port 7 C Port 8 Port 9 Port 10 Apply Fault Relay Alarm interface SNTP Configuration SNTP Simple Network Time Protocol is a simplified version of NTP which is an Internet protocol used to synchronize the clocks of computers to some time reference Because time usually just advances the time on different node stations will be different With the communicating programs running on those devices it would cause time to jump forward and back a non desirable effect Therefore the switch provides comprehensive mechanisms to access national time and frequency dissemination services organize the time synchronization subnet and the local clock in each participating subnet peer Daylight saving time DST is the conventio
100. y parameter 32767 Use the spanning tree max age switch config spanning tree max global configuration command lage 15 to change the interval between messages the spanning tree receives from the root switch If a switch does not receive a bridge protocol data unit BPDU message from the root switch within this interval it recomputed the Spanning Tree Protocol STP topology Use the spanning tree hello switch config tspanning tree hello time global configuration time 3 command to specify the interval between hello bridge protocol data units BPDUs MICROSENS GmbH amp Co KG KueferstraBe 16 59067 Hamm Germany Tel 49 23 81 94 52 0 FAX 100 www microsens com Manageable Gigabit Ethernet Switch with SFP User manual Page 76 83 Netstar Commands evel Description spanning tree forward time seconds Use the spanning tree forward switch config spanning tree time global configuration forward time 20 command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the port begins forwarding Use the spanning tree cost switch config interface fastEthernet interface configuration 2 command to set the path cost switch config if stp path cost 20 for Spanning Tree Protocol STP calculations In the event of a loop spanning tree considers the path cos