1. E2 Select a surge absorber that has a maxi mum circuit voltage greater then that of the peak voltage of the power supply paraa F FG i Lf G a Lightening Surge Absorber 3 Grounding Cautions Be sure to create an exclusive ground for the Power Cord s FG terminal Use a grounding resistance of 100 Q a wire of 2 mm or thicker or your coun try s applicable standard The SG signal ground and FG frame ground terminals are connected inter nally in the GP unit When connecting the SG line to another device be sure that the design of the system connection does not pro duce a shorting loop The grounding wire should have a cross sectional area greater then 2 mm Create the connection point as close to the GP unit as possible and make the wire as short as possible When using a long grounding wire replace the thin wire with a thicker wire and place it in a duct Exclusive Grounding BEST GP unit Other Equipment I Common Grounding OK Other GEO Equipment Common Grounding Not OK Other PP unit Equipment 4 All GP Input and Output signal lines must be separated from all operating circuit Dower cables If this is not possible use a shielded cable and ground the shield Securing the USB cable con nection IMPORTANT When using USB Host Interface in Hazardous Locations please fi
2. GP Unit Side S2L3 5 12 90F lt made by Weidmuller gt Connector Terminal Block B2L3 5 12LH lt made by Weidmuller gt Pin Arrangement Pin Signal Name Direction Meaning 1 RESET IN_A Input External Reset Input RESET IN_B Input 3 RUN Output R RUN Signal O O 4 RUN Output O O 5 ALARM Output O O ALARM Signal O O 6 ALARM Output O O F BUZZER Output B Signal uzzer o 00o 8 BUZZER Output g ar fia 9 NC Not Connected do 10 NC Not Connected 11 SP Output Speaker Out 12 SP_GND Output Speaker Ground Input Circuit e Output Circuit F 1 ES aes Load 5 i O i 1 4 SAT TS DC E H 7 LE E F24V 1 4 g lig 1 E 5 4kQ i 10 kQ 5 Installations 1 Installation Requirements For easier maintenance operation and improved ventilation be sure to install the GP at least 100 mm 3 94 in away from adjacent structures and other equipment Unit immiin Be sure that the surrounding air tem perature and the ambient humidity are within their designated ranges Sur rounding air temperature O to 50 C Ambient humidity 10 to 90 RH Wet bulb temperature 39 C max When installing the GP on the panel of a cabinet or enclosure Surrounding ai
3. Installation Fastener E 1 J and secure the fastener GP Hook on the panel with a screw IMPORTANT Tightening the screws with too much force can damage the GP units plastic case The necessary torque is 0 5 Nem 3 Wiring and attaching detaching the AUX connector GP 3400 series only IMPORTANT Be sure to remove the AUX Connector from the GP unit prior to starting wiring Failure to do so may cause an electric shock m Items Required to Wire Connectors Screwdriver Recommended type SDI Product No 900837 lt Weidmuller Japan gt If another manufacturer is used be sure the part has the following dimensions point depth 0 4 mm 0 02 in point height 2 5 mm 0 10 in length from the point to the handle 80 mm 3 15 in Point shape should be DIN5264A and meet Security Standard DN EN60900 Also the screwdriver s tip should be flat as indicated in order to access the narrow hole of the connector x O Screwdriver Tip Shape m Detachment Turn the tabs on the levers at both ends of the connector and the connector is released from the GP m Wiring and attachment 1 Insert the tip of the screwdriver into one of the square holes Then insert the cable into the corresponding round hole When you pull out the screwdriver the cable is locked For the pin assignment of the AUX con nector refer to External Interfaces Wire 2 Screwdriver
4. Wiring the DC Type Power Cord m Power Cord Specifications Use copper conductors only Power Cord 0 75 to 2 5 mm2 Diameter 18 12 AWG Conductor In Type Simple or Stranded Wire 7 mm Conductor 2 1 If the Conductor s end individual wires are not twisted correctly the end wires may either short against each other or against an electrode m Power Connector Plug Specifications 24 V ov Grounding Terminal connected to the GP chassis The power connector plug is CA5 DCCNM 01 made by Pro face or MSTB2 5 3 ST 5 08 made by Phoenix Contact When connecting the Power Cord use the following items when performing wiring Items are made by Phoenix Contact Recomended SZF 1 0 6x3 5 Driver 1204517 Al 0 75 8GY 3200519 Recomended Al 1 8RD 3200030 Pin Terminals Al 1 5 8BK 3200043 Al 2 5 8BU 3200522 Recomended Pin Terminal a ans Crimp Tool m Connecting the GP Power Cord 1 Confirm that the GP unit s Power Cord is unplugged from the power supply When using GP 3300 Series remove the power connector plug from the right side of the main unit the rear face for the AGP 3310T 3360T When using GP 3400 Series the power connector plug is packaged with other accessories Strip the power cord twist the conductor s wire ends insert them into the pin terminal and crimp the terminal Attach the
5. certification s information refer to the Pro face Home page lt Cautions gt Be aware of the following items when building the GP into an end use product The GP units rear face is not approved as an enclosure When building the GP unit into an end use product be sure to use an enclosure that satisfies standards as the end use product s overall enclosure The GP unit must be used indoors only Install and operate the GP with its front panel facing outwards If the GP is mounted so as to cool itself naturally be sure to install it in a verti cal panel Also it s recommended that the GP should be mounted at least 100mm away from any other adjacent structures or machine parts The tem perature must be checked on the final product in which the GP is installed Serial Interface COM2 is not Limited Power Source For use on a flat surface of a Type 4X Indoor Use Only and or Type 13 Enclosure Hazardous Locations Compliance and Handling Cautions 1 Power and input output wiring must be in accordance with Class I Divi sion 2 wiring methods Article 501 10 B of the National Electrical Code NFPA 70 within the United States and in accordance with Sec tion 18 152 of the Canadian Electrical Code for units installed within Can ada Suitable for use in Class Division 2 Groups A B C and D Hazardous Locations or Non Hazardous Locations only WARNING Explosion hazard substitution of any components ma
6. 2 Insert the wired AUX connector into the auxiliary I O or sound output interface AUX on the left side of the GP unit on If the connector cannot be fully inserted turn the tabs on the levers at both ends of the connector in the reverse direction and insert the connector 1 Wire should be AWG 22 to AWG 18 thick and twisted Applicable wire sizes are UL1015 and UL1007 2 Be sure to strip from 6 5 to 8 0 mm 0 26 to 0 31 in of cover from the wire Be sure to strip only the amount of cover required If too much cover is removed the end wires may short against each other or against an electrode which can create an electric shock If not enough cover is removed the wire cannot carry a charge Do not solder the wire itself This could lead to a bad or poor contact Insert each wire completely into its opening Failure to do so can lead to a unit malfunction or short either against wire filaments or against an electrode 3 Do not rotate the point of the screwdriver inside the square shaped opening It may cause a malfunction Wiring A WARNING To avoid an electric shock prior to connecting the GP unit s power cord terminals to the power terminal block confirm that the GP unit s power supply is completely turned OFF via a breaker or similar unit Any other power level can damage both the GP and the power supply When the FG terminal is connected be sure the wire is grounded 1
7. GP 3300 3400 Series Installation Guide l I AX HA Caution Be sure to read the Warning Caution Information on the attached sheet before using the product Package Contents 1 GP Unit 1 2 English and Japanese installation Guides 1 of each lt This Guide gt Warning Caution Information 1 Installation Gasket 1 attached to the GP unit 5 Installation Fasteners Set of 4 RCA BNC Convertor 1 AGP 3360T AGP 3450T oy AUX Connector 1 GP 3400 a Ep 8 Power Connector 1 Attached to the GP unit for GP 3300 Series Zu SC 3 En nego 9 USB Cable Clamp 2 port 1 set Holder 1 Cover 2 GP 3400 Series Sd 10 USB Cable ca 1 port 1 Holder 1 Clamp 1 All GP 3300 Series except AGP 3310T 3360T Z D 11 USB Cable ae 1 LO Clip 2 Tie 2 AGP 3310T 3360T EE BD ZS SEE eS This unit has been carefully packed with special attention to quality However should you find anything damaged or missing please contact your local GP distributor immediately About the Manual For the detailed information on GP3000 series refer to the following manuals GP3000 Series Hardware Manual Maintenance Troubleshooting The manuals can be selected from the help menu of GP Pro EX or downloaded from Pro face Home Page URL http www pro face com otasuke When using GP 3300 Series with Pro De
8. ch the GP unit s rear face of the shown below to fix the USB holder USB host interface by the same proce 2 dure 3 Insert the USB cable into the USB Host Interface 4 Attach the USB cover to fix the USB cable Insert the USB cover into the m Detaching the USB cable tab of the USB holder 1 Remove the USB cable while pushing USB Holder the grip section of the clip When the clip is removed from the USB cable cut the tie making sure not to damage the cable 3 GP 3400 Series units IMPORTANT m Attaching the USB Holder When using the GP be sure to attach all the 2 USB covers m Removing the USB Holder 1 Lift up the tab of the USB holder and then remove the USB cover as shown below USB Holder Z USB Cover 2 After removing the USB cable remove the picks pushing the USB holder from both top and bottom Installation prerequisites for standards The GP 3300 3400 Series units are UL c UL listed products UL File No E220851 UL File No E182139 UL c UL Prod ct Model No Registration Model No AGP3300 L1 D24 3280007 03 AGP3300 S1 D24 3280007 02 AGP3300 T1 D24 3280007 01 AGP3301 L1 D24 3280007 13 AGP3301 S1 D24 3280007 12 AGP3302 B1 D24 3280007 24 AGP3310 T1 D24 3710011 01 AGP3360 T1 D24 3710011 02 AGP3400 T1 D24 3280035 01 AGP3400 S1 D24 3280035 02 AGP3450 T1 D24 3280035 31 For the detailed
9. e The VCC output is not protected against overcurrent To prevent damage or unit malfunctions use only the rated current m COM2 Always connect close to the GP unit s COM port when terminating with the termina tion pins TRMRX TRMTX Recommended Cable XM2A 0901 lt made by OMRON Corp gt Connector XM2D 0901 lt made by OMRON Corp gt AGP 3302B only Recommended Jack Screw XM2Z 0073 lt made by OMRON Corp gt Recommended Cable Cover XM2S 0913 lt made by OMRON Corp gt Fitting fastener 4 40 UNC Ping RS422 RS485 Except AGP 3302B RS422 AGP 3302B only in Signal Name Meaning Signal Name Meaning Termination 3 1 TRMRX Receiver side 100 RDA Receive Data A 2 RDA Receive Data A RDB Receive Data B 3 SDA Send Data A SDA Send Data A 4 RS RTS Request for Send ERA Data Terminal Ready A 5 SG Signal Ground SG Signal Ground 6 VCC 5 V 5 Output 0 25 A T CSB Clear to Send B T RDB Receive Data B SDB Send Data B 8 SDB Send Data B CSA Clear to Send A Termination 9 TRMTX Receiver side 100 Q ERB Data Terminal Ready B Frame Ground Frame Ground shell FG Common with se FS Common with SG 1 The VCC output for Pin 6 is not protected against overcurrent To prevent damage or unit malfunctions use only the rated current m AUX Input Output and Sound Output Interface Supported by GP 3400 series only
10. ept for AGP 3302B s Ethernet Interface LAN 10BASE T 100BASE TX This interface uses an RJ 45 type modular jack connector 8 pins Except for AGP 3301 AGP 3302B m Power Connector Socket n USB Host Interface USB Complies with USB 1 1 Uses a TYPE A connector Power supply voltage 5 VDC 5 Output current 500 mA max The maximum communication distance 5m G Serial Interface COM1 D sub 9 pin plug type RS232C RS422 and RS485 are switched by software AGP 3302B supports RS232C only H Serial Interface COM2 D sub 9 pin socket type RS422 and RS485 are supported AGP 3302B has D sub 9 pin plug type and supports RS422 only CF Card Cover Except for AGP 3302B J Dip Switches Located inside the CF Card Cover Except for AGP 3302B Left Side EL AGP 3300T AGP 3450T K AUX Input Output and Sound Output Interface AUX Used for external reset alarm output buzzer output and sound output Except for GP 3300 series AUDIO Input Interface L IN MIC It s an interface to which a microphone is connected A mini jack connector 3 5 mm is used Supported by AGP 3360T AGP 3450T only VIDEO Input Interface V IN It s an interface to which a video camera is connected NTSC 59 9 Hz and PAL 50 Hz are supported A RCA connector 75 Q is used Supported by AGP 3360T AGP 3450T o
11. he detailed information be downloaded and refer the Declaration of Conformity from Pro face Home Page Digital Electronics Corporation 8 2 52 Nanko higashi Suminoe ku Osaka 559 0031 JAPAN TEL 81 0 6 6613 3116 FAX 81 0 6 6613 5888 http www pro face com The information in this document is subject to change without notice O Copyright 2005 Digital Electronics Corporation All rights reserved PFX104042A AGP3300 3400 MT12E BTH 2012 3 SS F Addendum Anexo Annexe PHA99478 08 2018 California Proposition 65 Warning Lead and Lead Compounds Advertencia de la Proposicion 65 de California Plomo y compuestos de plomo Avertissement concernant la Proposition 65 de Californie Plomb et compos s de plomb AXWARNING This product can expose you to chemicals including lead and lead compounds which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov All trademarks are the property of Schneider Electric SE its subsidiaries and affiliated companies Schneider Electric USA Inc 800 Federal Street Andover MA 01810 USA 888 778 2733 www schneider electric us ADVERTENCIA Este producto puede exponerle a qu micos incluyendo plomo y compuestos de plomo que es son conocido s por el Estado de California como causante s de c ncer y defectos de nacimiento u otros da os reproductivo
12. higher for an extended period of time the screen contrast level may decrease from its original level of brightness External Interfaces IMPORTANT e For instructions on how to connect to other devices always refer to the GP Pro EX Device PLC Connection Manual Always connect the 5 SG Signal Ground of the GP unit to the connected device especially if the connected device is also not isolated Failure to do so may damage the RS232C RS422 RS485 circuit m COM1 Recommended Cable Connector XM2D 0901 lt made by OMRON Corp gt Recommended Jack Screw XM2Z 0073 lt made by OMRON Corp gt Recommended Cable Cover XM28 0913 lt made by OMRON Corp gt Fitting fastener 4 40 UNC Pin RS232C RS422 RS485 Except AGP 3302B Signal Name Meaning Signal Name Meaning 1 cD Carrier Detect RDA Receive Data A 2 RD RXD Receive Data RDB Receive Data B 3 SD TXD Send Data SDA Send Data A 4 ER DTR Data Terminal Ready ERA ra Terminal Ready 5 SG Signal Ground SG Signal Ground 6 DR DSR Data Set Ready CSB Clear to Send B 7 RS RTS Request to Send SDB Send Data B 8 CS CTS Clear to Send CSA Clear to Send A Called status display p s 9 CI RI VCC 5 V 5 Output 0 25 A ERB Data Terminal Ready B Frame Ground Frame Ground shell FG Common with se FS Common with SG 1 The RI VCC selection for Pin 9 is switched via softwar
13. ng the diagram pass the tie through the clip hole Next turn the tie and pass it slightly through the head the clip will be lightly affixed on the USB cable so that the USB cable can pass through the center of the tie loop e Check the direction of the head before hand and make sure that it is in the position where the USB cable is through the center of the tie loop so that the tie can pass through the head Pass the tie through the head lightly because once it has been tightened it cannot be loosened again Tighten according to Step 5 The provided tie can be substituted with the Pro face made CA8 USBATALL 01 or other commercially available items with width 2 5 mm 0 10in and thickness 1 1 mm 0 04in 4 Insert the USB cable from Step 3 all the way in to the USB host interface with pushing the clip tab Make sure that the clip tab cannot be removed from the USB that is hung on the GP Insert with pushing the clip tab 5 Following the diagram completely 1 Before starting the procedure orient tighten the tie and thoroughly affix the two tabs on both sides of the USB the clip on the connector shell Holder in the direction of the arrows in the figure and remove the USB Cover Tabs i igs gt we 2 Attach the USB holder to the USB Host Interface part of the main unit Hook the lower pick of the USB holder to the attachment hole of the main y unit and then insert the upper pick as Atta
14. nly N Speaker Output Interface SPEAKER OUT A mini jack connector 3 5 mm is used Supported by AGP 3310T AGP 3360T only The following is each part for the AGP 3310T 3360T AGP 3360T Front co ee H AGP 3360T AGP 3360T AGP 3360T Rear Bottom Right Side 3 General Specifications m Electrical Specifications AGP 3300 3301 3310T 3360T AGP 3302B AGP 3400 3450T Input Voltage DC 24 V E Rated Voltage DC 19 2 to 28 8 V 2 Allowable o Voltage Drop 5 ms max 10 ms max o Power Consumption 26 W max 18 W max 28 W max In Rush Current 30 A max Voltage Endurance AC 1000 V 20 mA for 1 minute between charging and FG terminals Insulation Resistance DC 500 V 10 MQ min between charging and FG terminals m Environmental Specifications Surrounding Air ont Temperature 0 to 50 C Storage Temperature 20 to 60 C Ambient Humidit 10 to 90 RH Wet bulb temperature 39 C max no y condensation Physica Storage Humidity 10 to 90 RH Wet bulb temperature 39 C max no condensation Dust 0 1 mg m and below non conductive levels Pollution Degree For use in Pollution Degree 2 environment 1 When using a model with a monochrome LCD or a STN Color LCD model in an environment where the temperature is 40 C or
15. r temperature indicates both the panel face and cabinet or enclosure s internal temperature Panel Face Inside Cabinet Be sure that heat from surrounding equip ment does not cause the GP to exceed its standard operating temperature 2 GP Installation 1 Create a Panel Cut and insert the GP into the panel from the front Unit mm in Panel r lt 3 0 12 thickness X maa e gt GP A Panel oF x Y thickness ap 3300 156 07 128 5 1610 06 i to pace 16 1444 14 869 041 5 0 10 20 204 5 159 51 1 6 0 06 GP 3400 0 o e me 18 0544 6 2819 4 10 0 10 39 2 Confirm that the installation gasket is attached to the GP unit and then place the GP unit into the Panel from the front IMPORTANT It is strongly recommended that you use the installation gasket since it absorbs vibration in addition to repelling water For the procedure for replacing the installa tion gasket refer to GP3000 Series Hard ware Manual 3 The following figures show the four 4 fastener insertion slot locations Insert each fastener s hook into the slot and tighten it with a screwdriver Insert the installation fasteners securely into the insertion slot recess Foot Top E S oo G Insertion Slots Ges oG EEEE Bottom The figure shows the GP 3300 series Insertion Slot Recess Hook the fastener on the Recess o Panel
16. s Para mayor informaci n visite www P65Warnings ca gov Todas las marcas comerciales son propiedad de Schneider Electric SE sus filiales y compa as afiliadas Importado en M xico por Schneider Electric M xico S A de C V Av Ejercito Nacional No 904 Col Palmas Polanco 11560 M xico D F 55 5804 5000 www schneider electric com mx AVERTISSEMENT Ce produit peut vous exposer des agents chimiques y compris plomb et compos s de plomb identifi s par l tat de Californie comme pouvant causer le cancer et des malformations cong nitales ou autres troubles de l appareil reproducteur Pour de plus amples informations pri re de consulter www P65Warnings ca gov Toutes les marques commerciales sont la propri t de Schneider Electric SE ses filiales et compagnies affili es Schneider Electric Canada Inc 5985 McLaughlin Road Mississauga ON L5R 1B8 Canada 800 565 6699 www schneider electric ca 2018 Schneider Electric All Rights Reserved Reservados todos los derechos Tous droits r serv s Schneider
17. signer refer to AGP 3300 Series User Manual PDF File AGP 3300 Series User Manual can be selected from Manual in the Install dialog box displayed after the CD ROM of Pro Designer is inserted Part Names and Functions Front AGP 3300T AGP 3450T Bottom CF Card Cover Open Rear Right Side AGP 3300T DF TETERE J GP 3450T AGP 3450T AGP 3450T Name Description gt Status LED Operation Mode Drawing OFFLINE In operation RUN In operation STOP When power is turned on In operation Major Error Backlight burnout or GP malfuction During software startup Logic execution mode when logic is enabled Color Indicator Green ON Flashing ON Flashing ON Flashing Red Orange 1 When backlight replacement or repair of the GP is required please contact your local GP distributor The logic program is disabled in the AGP 3302B 3301L 3301S The Status LED turns on only in Operation Mode Drawing wW Expansion Unit Interface EXT Used to connect an expansion unit that can transmit data O CF Card Access LED Lit in green when the CF Card is inserted and the cover is closed or when the CF Card is being accessed Exc
18. terminal to the power connector IMPORTANT Use a flat blade screwdriver Size 0 6 X 3 5 to tighten the terminal screws The torque required to tighten these screws is 0 5 to 0 6 Nem 5 7 Lbeln Do not solder the cable connection 2 a 4 Attach the Power connector Plug to the GP AGP 3300T Power connector Plug 2 Power Supply Cautions Input and Output signal lines must be separated from the power control cables for operational circuits To improve noise resistance be sure to twist the ends of the power cord wires before connecting them to the Power connector Plug The GP units power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal lines To reduce noise make the power cord as short as possible If the supplied voltage exceeds the GP unit s range connect a voltage trans former Be sure to use a low noise power sup ply between the line and the ground If there is an excess amount of noise connect a noise reducing transformer The temperature rating of field installed conductors 75 C only IMPORTANT Use voltage and noise reducing trans formers with capacities exceeding Power Consumption value Must be used with a Class 2 Power Supply 24 VDC Connect a surge absorber to handle power surges Be sure to ground the surge absorber E1 separately from the GP unit
19. x the USB cable with the USB Holder If it s not fixed so that the connector on the GP s side and the PLC s side cannot come out the USB Host Interface can not be used in the Hazardous Loca tions Input Output Signal Line Cautions 1 GP 3300 Series units Except for AGP 3310T AGP 3360T E Attaching the USB Cable Clamp 1 Insert the USB holder into the slot in front of the GP unit s USB port and pull it down and forward 2 Pass the band of the USB cable clamp through the bridge of the USB holder Bridge USB Holder 3 Insert the USB cable into the port Fasten the band around the plug and secure it with the clamp USB Holder o m Removing the USB Cable Clamp 1 Lower the tab and lift the clamp to release the plug 2 AGP 3310T 3360T units Be careful for the edge of the clip not to cut the fingers m Attaching the USB Cable Clip 1 Mount the clip to the USB mark lt gt connector shell so that it overlaps The clip is corresponding to 27 to 43 5mm 1 06 to 1 71 in length of the USB connector A 27 to 43 5mm ibs to 1 71 in 2 Align the clip and the USB cable connector shell and adjust the position of the holes where the clip is affixed To ensure stability select the clip hole position that is closest to the base of the connector shell and that is not making contact with the base Pass the tie through here 3 Followi
20. y impair suitability for Class I Division 9 WARNING Explosion hazard when in hazardous locations turn OFF power before replacing or wiring modules 5 WARNING Explosion hazard confirm that the power supply has been turned OFF before disconnecting equipment or confirm that the location is not subject to the risk of explosion WARNING Explosion hazard do not disconnect equipment unless power has been switched off or the area is known to be Non Hazardous In the case of use in Hazardous Locations be sure to check that the externally connected unit and each interface have been fixed with screws and locked In Hazardous Locations it s impossible to insert or pull the cable from the applicable port Be sure to check that the location is Non Hazardous before inserting or pulling it CE Marking The AGP3300 L1 D24 AGP3300 S1 Inquiry Do you have any questions about difficulties with your GP Please access our site anytime that you need help with a solution http www pro face com otasuke Note Please be aware that Digital Electronics Corporation shall not be held liable by the user for any damages losses or third party claims arising from the uses of this product D24 AGP3300 T1 D24 AGP3301 L1 D24 AGP3301 S1 D24 AGP3302 B1 D24 AGP3310 T1 D24 AGP3360 T1 D24 AGP3400 S1 D24 AGP3400 T1 D24 AGP3450 T1 D24 units are CE marked EMC compliant products For t