Guardall BM5 Keypad User Manual

image

Contents

1. own PIN 4 to 6 digits or Electronic Key Change PIN All Users The Engineer also has control of User 2 and User 3 PINs and will see Press V Press A User 2 also has control over User 3 PIN and will see Key in the number to select the required User PIN As User 3 can only change their own PIN this option menu is not displayed All Users will now see Enter the new PIN followed by or insert an electronic key The display will change to Re enter PIN or key to validate the change After a few seconds press X to return to the main menu Log out Press X and log in again to check the PIN has been allocated If the PIN is invalid or already used the following is displayed for a few seconds When the New PIN menu re appears try again If different PINs are entered the following is displayed for a few seconds Try again Option 04 View Log Not User 3 The Log holds up to 10 events with their time amp date When entered the most recent event is displayed Use the A key to view previous events and the W key to return to more recent ones Note the log rolls over so having just enetered the menu pressing V will go to the oldest event stored Alarm Heat Pre Alarm Heat Signal Lost Alarm Fire Pre Alarm Fire Reset Fault Power Soak On Soak Off Limit Exceeded Limit Reset Watchdog Test Heat Test Fire Option 05 View Threshold Not Us
2. Guardall BM5 Keypad User Manual The Keypad acts as a low level service aid It provides advanced diagnostics in the chosen language and uses universal symbols to annotate the indicator LEDs The keypad supports 3 levels of users Engineer Has access to the full range of set up menus Refer to the BM5 Engineering Manual 320702 for details This is available free of charge from the Guardall Technical Hot Line phone 44 0 131 333 3802 User 2 Has access to all features described in this guide User 3 Can only Reset the BMS after an alarm change User 3 PIN number and the language displayed LED LCD Exit Menu Indicators Display Quit Option Scroll Menu Up Down Electronic Key Socket LED Indications Green ODE System functioning correctly Green oo Record Soak active Green et Alignment Set up mode Yellow Pa Service Engineer Required Red Tan Pre Alarm investigate Red ops Smoke Alarm active Red s z Heat Alarm active Yellow hy Fault signal Under normal operation the OK LED flashes Wiring The Keypad The keypad is wired to CN4 on the Receiver PCB by connecting terminal to to I to A and P to B NOTE On older Receiver PCBs which do not have a plug on connector block and are marked issue 1 or 2 or 3 or 4 or A some connections are reversed Connect to to I to B and P to A Electronic Key An Electronic Key can be substituted for the User or Engineer PIN numbers The
3. appear even if no signal is present Over time as the lens gets dirty the Guardall BM5 adjusts to compensate for the reduction in the strength of the signal When the compensation limit is approached a warning is displayed If the limit is exceeded fixed at 50 and 20 a fault will be signalled and the following displayed The lens and housing must be cleaned to restore the signal to the initial strength and the signal voltage re fixed NOTE This fault condition cannot be cleared until the signal voltage has been re fixed This requires Engineer level system access Keypad Menus Only the options available to the User are displayed After a few seconds the display changes to the Main Menu from the Signal Status page Press W to move down and view the available menu options To move back up use A To select a menu option key in it s number To exit from an option return to a previous menu or log out press X To get help in entering data press Option 01 Reset All Users This will clear latched Alarm or Fault conditions provided the cause of the condition has been cleared It is functionally identical to other reset methods described in the Engineering Manual If the Compensation Limit has been exceeded the following will appear and the Fault Light will stay on Engineer level access is now required to Reset the signal voltage after cleaning the lenses Option 02 All 3 users may select their
4. er 3 Use the AW keys to view the threshold settings These are only configurable by the Engineer using menu 40 With default settings they appear as follows Press V Press A Press V Press A Press A Press V Press A Option 06 Set Date Not User 3 The current Date will be displayed To change it press J Enter as Day Month Year e g 07072000 If valid you will be returned to the Date set to menu If invalid the following error message will be displayed Try again when Date Enter re appears Press X to return to the main menu Option 07 Set time Not User 3 The current Time will be displayed To change press lt 1 Enter the Time as Hour and Minutes in 24hr clock format e g 0555 05 55 If valid you will be returned to the Clock set to menu If invalid the following will be displayed Try again when the Clock Enter menu re appears Press X to return to the main menu Option 08 Fire Alarm Test Not User 3 The following is displayed Check the following Receiver System and Keypad Fire LEDs are on The Smoke Fire Relay is activated Test Fire message is recorded in the Log A Reset 01 is required after the Fire Test Press X to return to the main menu Option 09 Heat Test Not User 3 The following is displayed Check the following System and Keypad Heat LEDs are on Output rela
5. re is a maximum of three codes or keys per system LCD Display One of three Rest Pages is normally displayed Use the AW keys to select the message required Press W Press A Press W Press A Alarm Display If an alarm or fault occurs the Guardall BM5 heading message is replaced as shown below The following messages may be displayed Alarm Fire Highest Priority Alarm Heat 4 Pre Alarm Fire 4 Pre Alarm Heat 4 Signal Lost Signal Increase 4 Limit Exceeded 4 Fault Lowest Priority Only the message that has the highest priority will be shown Use the AW keys to display Obscuration Modulation or Date and Time as required Log On For access to other keypad functions the User must Log On using a PIN or Electronic Key The factory default PINs are Engineer 9999 User2 1111 User3 2222 To change a PIN see Keypad Menu Option 02 below Enter the appropriate PIN The display will show Then press 4 Alternatively insert the Electronic Key If valid the user is logged on If an invalid PIN or Key is entered the PIN error message is displayed Press X and try again If no key presses occur for 5 minutes the User will be logged off Signal Status The first page displayed after log on shows whether the signal beam is within the acceptable range of percentage compensation NOTE As compensation is only slowly up dated this message may
6. y configured for Heat is activated lt A Test Heat message is recorded in the Log A reset 01 is required after the Heat test Press X to return to the main menu Option 10 LED Test Not User 3 The following is displayed Check the following LEDs on the Keypad will be alternately pulsed The Receiver LEDs will be pulsed Note The Fault LED will show only short flashes and the fault output relay will also be pulsed Press X to return to the main menu Option 99 Set Language All Users The default language is English Press V Press A Press V Press A Press 1 2 3 4 or 5 to select the desired language The display will automatically return to the main menu in the new language Guardall Limited Lochend Industrial Estate NEWBRIDGE EH28 8PL UK Sales 44 0 131 333 2900 Tech Hotline 44 0 131 333 3802 320703 0C

Download Pdf Manuals

image

Related Search

Related Contents

Installing the Painless #10102 Harness in an early Fiat  Guía del usuario  Vulcan - DMC Equipamentos  Cliquez sur le lien pour télécharger la  Netgear WG302 User's Manual  Bedienungsanleitung  Transcend 512MB, DDR2, 533Mhz, PC4200/4300, JetRam, CL4      PR22 MHC Streptamer Manual_0005_2012 Version 2  