Home

GDV Sport - GDV Argentina

image

Contents

1. Copy to clipboard Fit to window Set maximal enlargment Zoom in Zoom out Print all images Print images Fit ellipse automatically Turn GDV image upside down Mirror GDV image horizontally Save colored images Compute average image Capture GDV View Menu item Operation Copy to clipboard Copies the frame being in the screen to the clipboard taking into account coloring sectors and viewing Fit to window Fits maximal quantity of GDV images in the screen simultaneously the quantity of images in the screen depends on the monitor resolution Set maximal enlargement Scales up the selected GDV image for the whole window Zoom in Scales up the selected GDV image image Zoom out Scales down the selected GDV image image Print all images Calls the Preview window Print image Calls the Print preview window and prints out the selected GDV image Fit ellipse The program automatically recalculate inscribed ellipse overriding automatically previously made manual changes for single GDV image or for all loaded GDV images Turn GDV images Rotates GDV image on 180 upside down Mirror GDV image horizontally Save colored images Compute average image View The image is a rectangular matrix of points of the form I x y with size w by h Mirror GDV image horizontally means to transform the image so that I x y will take the position I wx y Save GDV images
2. The subject s personal data and the GDV images file list are saved in the file with the sbj extension The file is created on the disk and its content is updated at the moment when you finish working with the program Inside the file contains references to the files with GDV images That is to transfer the information onto another computer you need to copy the required sbj files together with the appropriate files with GDV images keeping their arrangement with reference to each other in the directory structure For the convenience of the data storage and transfer to other computers it is recommended to keep a certain structure of subject data folders on the disk In particular the following example schematically displayed is very convenient In this case to transfer the information about e g Adam Smith you need just to copy the folder Adam Smith with all its contents and the file Adam Smith sbj If there is no need to transfer the GDV images you can just copy the sbj file In such case the program will enable you to preview the previously calculated data but re processing will be inaccessible My computer 2010 01 20 2010 03 12 stadium D Calibration 2010 03 16 office Without filter Capture1 2010 02 19 With filter GDV Adam Smith GDV images Capture Data 2010 03 14 Investigations 1 Adam Smith sbj Sport teams Bob Marley GDV images Bob Marley sbj Investigations 2 materials When y
3. Close the program Print GDV mages Capture GDV mages Load GDV mages The Programs button makes it possible to start any program from the GDV Software package installed on the computer When the selected program is launched the files of subjects open in the current programs are automatically loaded into it Further on during work there will be automatic synchronizing of the altered data among all programs to where the altered subject s file is loaded Pinte Tport GDV Diagram GDV Energy Fie Add new subject entry or load data from disk New subject Load subject Load per list Remove from list GDV capture data is not added GDV Sport gt Working with program gt General description of the program GDV Sport gt Working with program gt Adding an entry of a new subject data Adding an entry of a new subject data On page Subject list there are two lists the upper one is responsible for the information about subjects and the lower one for the information about captures assigned to each of subjects loaded into the upper list To work with the program it is necessary to add the information about a new subject into the upper list press the button highlighted with the color in the figure r Omaa K pert Add new subject entry or load data from disk Load subject Load per list Remove from list GDV capture data is not added Calibration
4. 2011_03_13 16 06 MonTueWedthu Fri A J J Jij2f3 Gerd cason fats e 7 e 9 ao SI 11 12 BEM 14 15 16 17 EER a8 19 20 21 22 23 24 25 26 27 28 29 30 31 S GDV images without filter i Hi No data es Load GDV images GDV images with filter No data Capture GDV images Cancel Done In the lower part of the window there are the control elements that enable to add GDV captures for the given subject By default it will be named Capture 1 If necessary you can enter the name corresponding to the specific character of the test e g before and after treatment Right from this window using button Load GD images you can indicated the path to the GDV images with or without filter if the images have already been captured before and saved to disk Besides you can start the GDV Capture program to capture GDV images by button Capture GDV images The line Date is filled out automatically after loading or capturing GDV images Enter additional information about capturing in the field Remark Capt count Remark 1 e 3a Category E GDV capture Date Without filter With filter 2011_03_13 16 4 3 2009 10 46 59 AM is loaded is loadec 4 Calibration When you finish entering data press subject and the newly added capture Add opire at dat Done and on page Subject Lis
5. GDV Sport gt Working with program gt Pseudocoloring modes Pseudocoloring modes You can view GDV images in various pseudocoloring modes which enables to study the peculiarity of development of gas discharge more accurately Pseudocoloring is only represented in the programs of GDV Software complex All GDV images are saved on the disc in original palette of 256 tints of grey You can switch one pseudocoloring mode to another in the upper left corner of the page r The 1 Original image eR Inverted image K GDV images with fiter Intensive palette Solid palette Blue tte Omaa Cport 3K Moise Smith 2011_03_13 16 25 Calibration S N ose Load GDV mages Calculate following types of pseudo coloring are provided in the program Original image image as it was obtained from video camera and saved in AVI file Gray color palette containing 256 shades of gray from black to white is used Inverted image inverted gray color palette is used containing 256 shades of gray from black to white Particular small details and thin streamers are better seen in this palette than in the initial image Intensive palette image points are colored in one of eight colors The brightest glow points are colored in the shades of blue less bright points are colored in the shades of red Points the intensity of which is higher than the noise level but lower than the base noise level for the given
6. a dialog containing consecutively switched pages Part of pages is available only after loading or processing of data The program interface is designed in such a way that the user can consecutively realize construction and visualization of GDV Sport in accordance with standard analysis procedure When the program is launched the start page is displayed from where the user can start working Start work User manual About program When you select the User Manual button you will see the description of working with programs The menu item About program will display the data on the installed program version time and date of its issue the hardlock number and there is also a possibility to change the language of the user interface to any of the supported ones without re installing the program To do this you need to check the required language and restart the program The interface language will change for all programs in the package When you select JO w GDV Sport Version 1 3 8 Build date and time 3 28 2012 3 02 21 AM Copyright c Kirlionics Technologies International User s interface language English Change This program developed using following libraries wxWidgets 2 8 10 Boost 1 47 0 Start work click the left mouse button to go to the next page Subject list Pinte Tport Add new subject entry or load data from disk New subject Load subject Load per list Remove from lis
7. in the form of their display on the screen taking into account current coloring type sector fragmentation etc Processes averaged image and asks to save it Calls GDV image real size view window GDV Sport gt Working with program gt GDV Image menu GDV Sport gt Working with program gt Data table Data table The Data table page contains brief numeric information on basic parameters calculated in the GDV Sport program These data are presented in the Rating table The Rating table consists of lines with parameters calculated for each subject and columns containing the following information 1 N the ordinal number of the table line 2 NAME first name Middle name and Last name of the subject 3 Point its meaning is from minimum 1 to maximum 10 It characterizes the overall condition Is has a direct relationship with the parameter Energy Potential 4 Energy potential EP the parameter characterizing the relationship of the physiological and emotional state of the athlete It is calculated as a percentage maximum 100 EP is the characteristics of the subject s functional energy level for the period of study The higher EP the higher the potential reserve of the subject or the competitive readiness level for athletes High EP value characterizes purposefulness stress resistance high movement activity and a stock of potential reserves 5 Stress background SB the parameter characterizing the level o
8. the level of noise for each GDV image frame individually Base intensity is calculated on the basis of the analysis of histogram of image spectrum Statistical characteristics of spectrum are taken as the values of base intensity These characteristics correspond to the spectrum average value plus the value of its RMS average value of spectrum median of spectrum or peak of spectrum Minimal fragment area removal of fragments of glow with the glow area less than the given minimal area of fragment On default this parameter is 30 Working radius removal of all points of the image whose distance from which to the glow center is bigger than the given working radius The glow center is either calculated automatically as the center of gravity of all the glow points or set by the user after manual correction of the glow center The same value of coordinates of the glow center is used for all the frames of video file Intensity correction the intensity of all pixels of a GDV image increases or decreases by the same value that is automatically calculated by the program so as to bring the characteristics of the image spectrum most closely to the characteristics of the spectrum of test object GDV images taken during calibration OK to activate new parameters The loaded GDV images are automatically filtered from noise under new parameters and are renewed in the screen GDV Sport gt Working with program gt Noise filtration
9. will be used for correction and keeping the keyboard CTRL button pressed move the contour border Pinte Sport Eneroy paene HI Noise Smith 2011 03 13 16 25 GDV images without fiter GDv images with filter Calibration R J oad GDV images lt lt Back Calculate nn Besides sector division of the corresponding finger is superimposed on the GDV images Detailed information on the GDV image can be obtained using the mouse e when you move the cursor over the image the information is displayed in the lower part of the window cts Sport Ener ate v EA E EE noe Gnin 201103131625 GDV mages without filter GDV 4mages with filter r Omaa Cport ens EA EE ne Gnin 20110313 1625 GDV images without fiter GDv images with fiter Calibration Print GDV mages Capture GDV mages Load GDV mages N GDV Sport gt Working with program gt Correction of the center and ellipse for the GDV image of finger GDV Sport gt Working with program gt GDV Image menu GDV Image menu Contextual pop up menu can be called for any loaded GDV image Press right mouse button in the line showing frame s number and path to the file Contextual menu appears It consists of the following items r Eneray palette HIR Noise Smith 2011 0313 16 22 GDV images without filter GDV images with filter
10. 25 b E REE SE LRT RE ad G Calibration Print GDV images Capture GDV mages Load GDV mages lt lt Back Next gt gt N A A GDV image is a number of points pixels each of which is characterized by the glow intensity a value within 0 255 Zero intensity corresponds to the absence of glow in the given point and 255 indicate maximal glow intensity The GDV image spectrum is the function that determines the number of points with specified intensity Fig shows a typical GDV image spectrum The horizontal axis shows the intensity and the vertical one the number of image pixels with preset intensity Any video camera used to register GDV images has a certain error of performance Therefore the images contain evenly spread noise points of low intensity The figure shows the part of spectrum corresponding to there noise pixels in grey The blue color indicates the spectral region corresponding to the brightest and most informative point of gas discharge glow around the subject CAGDVData Smith Without filter 1R bmp Bie ks GDV Image Spectrum parameters Information Isoline Calibration data 6266 Spectrum parameters Maximum intensity 255 Minimum intensity 2 Mean intensity 24 RMS error of intensity 26 Peak intensity 18 Spectrum width 253 Pixel count Histogram position Intensity 44 Pixel count 177 Noise level 30 Pixels count axis maxi
11. 3 2011 4 18 26 PM isn t loaded isn t load w p to enter changes in the personal data of the selected subject The button Remove from list enables you to remove the selected recording about the subject from the program This action does not result in data file removal from the disk but only increases the memory space Using the button you can delete all loaded data from the program memory To work with the lower list the following buttons are provided s to add a new capture for the subject selected in the upper list e Edit data to introduce changes and to add comments to capture selected in the lower list s to delete capture selected in the lower list e To save changes press Save changes To switch to another GDV image page use the button Next GDV Sport gt Working with program gt Adding an entry of a new subject data GDV Sport gt Working with program gt Loading GDV images Loading GDV images Loading of GDV images is done on the GDV images page and also in the subject s window with the Load GDV images button it is highlighted with the color in the figure The files of GDV images are to have in their name the finger indices 1R 5R 1L 5L r Oraa Cport H Noise Smith 2011_03_13 16 22 GDV mages without filter Calibration To load GDV images you need to press the button Load GDV images in the shown up win
12. 7 37 PM GDV device model GDV Camera Pro with analog videocamera FTDI 13 6001 110310 Path to GDV images files C GDVData Calibration Radius error 0 01 should be less then 2 00 Area error 1 46 should be less then 5 00 Intensity error Filename Date and time of capture 0001 bmp 6 4 2011 12 07 09 PM 0002 bmp 6 4 2011 12 07 12 PM The renewed calibration data will be automatically recorded into all GDV images of the series that you see on the screen both with and without filter if any For an arbitrary set of GDV images Make sure that all programs of the GDV Software package are closed Run any program of the GDV Software package except GDV Capture GDV Viewer GDV Scilab Go to page of the list of subjects DO NOT LOAD sbj files Select in the menu Action the item Group calibration OTa Sport Calibration L New subject Load subject Add new subject entry or load data from disk GDV capture data is not added New subject Load subject data Load per list Last calibration info Calibration Group calibration Close the program 5 The GDV Capture 2 program will start Press the Load GDV images button in the upper left hand corner of the program window and select the GDV images of the test object that need recalculation Load GDV images GP see Energy palette X Type of connected GDV device GDV Camera P
13. DV images The demo version makes it possible to work only with built in data the functions of creating loading and saving files of subjects are blocked you also can not load GDV images from disk or start the GDV Capture to capture these files The program can simultaneously carry out the data processing for several subjects with a possibility of having several GDV captures for each of them e g taken on different dates A GDV capture is one or two sets of files of GDV images of fingers taken with and without filter In this program only GDV images without filters are required The list of captures and personal data of the subject name gender age etc are saved in the file or on the disk Therefore to process the subject s data it is necessary either to create a new file or to download the previously created one and then add the new capture When you want to close the program or delete subjects from the list a request will be made if you need to save all changes during this session Thus a typical working procedure looks as follows 1 Create a new file or download the existing one 2 Add the new capture 3 Download the subject s GDV images without filter 4 Calibration if this procedure has not been carried out before 5 Check settings of noise filtration pseudocoloring mode and if necessary introduce your corrections 6 Corrections of inner ellipses 7 Processing and analysis of the obtained data 8 Printi
14. EMF formats enable to save the file of the printed page in Windows Bitmap extension BMP or Windows changes the scale of the preview page Information on the number of pages is shown in the window status bar After pressing button Print window Print setup appears If you have a color printer the printer is automatically set for color printing Landscape page setup is given by default GDV Sport gt Working with program gt Printing out GDV images GDV Sport gt Working with program gt Saving printed documents Saving printed documents Any document a graph or GDV image that is formed in the program can be saved from the Print preview window To do this press the button Save to file in the upper part of this window The type of file is Windows Enhanced Metafile by default EMF extension but you can also select Windows Bitmap BMP extension It is advised to use the EMF format for saving pages as first of all images occupy much fewer space on disk in this format than in BMP format Secondly when these images are scaled in documents for example in Microsoft Word distortions are minimal GDV Sport gt Working with program gt Saving printed documents
15. GDV Sport gt Introduction GDV Sport Introduction Purpose of the program System requirements Recommended computer configuration Training level of a user Working with program General description of the program Adding an entry of a new subject data Loading GDV images Capturing GDV images Calibration Group calibration Noise filtration Pseudocoloring modes Correction of the center and ellipse for the GDV image of finger GDV Image menu Data table Summary Additional information Printing out GDV images Saving printed documents GDV Sport gt Introduction GDV Sport gt Introduction gt Purpose of the program Purpose of the program The GDV Sport program is designed to evaluate the psycho emotional status parameters expressed as peer review diagnostic decisions and integral indices reflecting the energy functional level of human body based on GDV images of human fingers The calculated parameters and indices express the potential of successfulness in the subject s activity The program is intended for evaluating the potential successfulness and efficiency of athletes and staff members of companies The individual rating of a person in the group is based on these characteristics The method is based on high correlation correlation coefficients are more than 0 85 of the indicated parameters and indices calculated independently by means of tests and peer review decisions with geometrical and brightness characteristics of G
16. ain Automatic capture 5 Press in the upper left hand corner of the program window and select GDV images of the test object that need recalculation 370 x 285 Energy level 1 Image transformation No transformation Tun aiinos Static GDV images bmp L Parameter name Parameter value 6 Press and then Save calibration results and close the GDV Capture 2 program CBO DS Gl B el regain C HD Ey catbraton o00s EY cabration 0002 HB Catbration ooo3 IB aperas JE oanez Parameter Value Date and time of calibration 6 4 2011 12 09 29 PM Date and time of GDV images capture 6 4 2011 12 07 37 PM GDV device model GDV Camera Pro with analog videocamera FTDI 13 6001 110310 Path to GDV images files C GDVData Calibration Radius error 0 01 should be less then 2 00 Area error 1 46 should be less then 5 00 Intensity error 1 21 should be less then 5 00 13911 13942 58 Filename Date and time of capture Inner radius irregularity Area error Intensity error 0001 bmp 6 4 2011 12 07 09PM 0 56 tolerance 4 00 6 82 tolerance 15 00 1 75 tolerance 8 00 0002 bmp 6 4 2011 12 07 12PM 0 55 tolerance 4 00 7 08 tolerance 15 00 1 99 tolerance 8 00 Dependence of the test object s glow area on noise level AUNE Value Date and time of calibration 6 4 2011 12 09 29 PM Date and time of GDV images capture 6 4 2011 12 0
17. cases the contour almost absolutely repeats the finger contour However sometimes the glow has outbursts and dark areas as a result of which the finger contour built automatically is not precise and requires manual correction In this case the contour can be manually adjusted the position of the center and the finger orientation can be corrected in order to have a more precise energy field picture In order to correct the finger center position move the mouse cursor to the displayed GDV gram center press the left button and move the cursor keeping the right button pressed r E Noise smith 2011_03_13 16 25 GDV images without filter GDv images with filter 1 1 B woon stert HH waar oC HB atan 10 Calibration Print GDV mages Capture GDV mages Load GDV mages N The finger orientation on a GDV gram can be corrected in a similar way In order to do that move the cursor to one of the displayed GDV gram axes press the leftt button and move the cursor keeping the left button pressed The kept axis will be rotated against the GDV gram center Pa xe L Eneroy paene EA GG Noise Smith 2011 03 13 16 25 GDV images without fiter GDv images with filter Calibration Bice C J oad GDV images lt lt Back Calculate In order to correct the contour mark the corresponding GDV gram move the cursor to touch the axis which
18. center exceeds the specified value are removed It should be emphasized that during the filtration procedure there is no physical removal of information from images all further calculations in the program are done as if all filtered pixels had zero intensity Therefore you can change the noise filtration parameters any time not losing the data on noise pixels The noise filtration parameters settings are carried out by the user The two main factors to select these parameters are the type of the used GDV Camera and specific features of the recorded GDV images In the Operation Manual to the GDV Camera you will find the recommendations helping to determine the correct parameter values You need to follow the principle of selecting the most contrast part of the glow that can usually be seen with a naked eye It is also important when you are registering the test object images to ensure such filtration parameters that the inner part of the glow would not contain noise pixels For the convenience of selecting optimal parameters of noise filtration the program can switch to different types of image pseudocoloring You can use the following way to control the correctness of the chosen parameters 1 Set the intensive or energy palette for loaded images Select the noise filtration parameters so that to avoid a large number of yellow dots Switch to the initial image palette Switch off the display of the filtered points Make sure that the v
19. dow and indicate the path to the folder where the GDV image set is stored then press the buttons l Select all and Open Tans J Smith 6 E G fv Dera vamenenua Th 13 03 2011 16 16 02 03 2011 16 02 Vima Ji With filter J Without filter Vima pa na Tun atines Static GDV images bme Parameter name Parameter value Calibration 5R lt Select all Vima pa na 5R bmp 1Lbmp 1R bmp 2L bmp 2R bmp 3Lbmp 3F v Open Tun pa nos Static GDV images C pnp S Rs Parameter name Parameter value The pictures of the subject s GDV images are loaded into the GDV image window Pinte A Noise Smith 2011_03_13 16 22 GDV images without filter GDv images with filter b By without meris 18 without fiter 2R HB without nrzranp HH without G Calibration S Capture GDV images GDV images taken without filter are loaded into the program Use the button for calibration of the loaded GDV images Use the button Print GDV images to print out the pictures of the loaded GDV images with an overlay of sector division by Korotkov Use the button if you want to reload GDV images GDV Sport gt Working with program gt Loading GDV images GDV Sport gt Working with program gt Capturing GDV images Cap
20. ension sbj GDV Diagram GDV Energy Field etc GZ Folder pattern ka File name pattern k Type of files in thelist Data files sbj File name C GDVData GDVEnergyField Crystal sbj C GDVData GDVEnergyField Fisher sbj C GDVData GDVEnergyField Luz sbj C GDVData GDVEnergyField Rooney sbj C GDVData GDVEnergyField Smith sbj Number of files in the list 0 Calibratic 2 Go to the GDV image page and select the required series 3 Press Calibration in the lower left hand corner of the program window or select the item Calibration from the menu Action rts Sport SK Noise Smith 2011_03_13 16 25 GDV images without filter GDV images with filter L i B without nter HB without fiter ar HB met nena HB without merat HH without prest Calibration Print GDV mages Capture GDV mages Load GDV images Calculate 4 The GDV Capture 2 program will start For further work press OK of the warning pop up window Type of connected GDV device GDV Camera Pro with analog videocamera FTDI 13 6001 110310 Image size 370 x 285 Energy level 1 Image transformation No transformation To complete calibration capture at least 10 GDV images ve of the test object and save them or load earlier captured images L Then press Process button E Do not show this message ag
21. f anxiety stress SB within 0 2 a totally calm completely relaxed person which may be the result of several factors a deep meditation complete inner peace the influence of psychedelics a deep sleep in a quiet phase chronic depression etc SB 2 4 a normal quiet state SB 4 6 an excited state characteristic of active work excitement intense activity SB 6 8 at least four possible situations e a response to a previous stressful situation an unpleasant conversation illness failure in the training process driving in stressful conditions etc e increased nervousness or stress accumulated over long periods of time emotional stress vegetative dysfunctions e people with a special type of mentality that can quickly switch from the state of extreme excitement and nervousness into a quiet state e the state of overtraining fatigue danger of injury SB in the range of 8 10 a very high stress background the peak of excitement Category All selected categories Sort criterio Score Descending X Capture Capture Energetic Stress as EE date category Score potential level 1 Smith 2011_03_13 16 4 3 2009 10 46 59 AM 3 217 Print The data table can be saved to a text file or printed out When you print out the rating table you can indicated the name of the group to which the subjects refer e g swimming The entered names are saved and you can select them afterwards If
22. frame are colored in yellow All image points removed by noise filtration are shown in white Solid palette all image points removed by noise filtration are shown in black color the rest of the points are shown in a monotonous bright color Use this palette analyzing sector s glow area and glow area of the whole image in order to avoid optical illusion which can occur if some points are not seen well as the coloring is similar to the coloring of noise points Blue palette color palette containing 256 shades of blue from black to bright blue is used Points with minimal intensity of glow are shown in dark almost black shades points with maximal intensity of glow are shown in bright almost blue shades This palette displays the glow similar to the way it can be seen in instrument s electrode by the naked eye Energy palette the image points are colored in one of the nine colors The brightest glow points are colored in blues the less bright ones are colored in reds oranges and violets All image points removed by the noise filtering algorithm are displayed in white GDV Sport gt Working with program gt Pseudocoloring modes GDV Sport gt Working with program gt Correction of the center and ellipse for the GDV image of finger Correction of the center and ellipse for the GDV image of finger Determination of the ellipse and glow center is built automatically when the GDV grams are load ed In most of the
23. ional activity of body and systems The state of energy deficiency can be attributed to total breakdown dysfunctions of separate organs or systems overfatigue neuro psychic stress over training In this state the subject can function normally in particular an athlete can show good results however a long period of such state leads to development of negative processes on psycho physiological or somatic level Necessity check up at the moment of measurements the subject is under stress which makes it impossible to adequately evaluate his psycho physiological readiness The given situation requires a more detailed psychological and medical examination In the table marks the qualities which by the result of processing GDV images are mostly pronounced for the subject C TTS A Category All selected categories zj Smith 2011_03_13 16 25 Print Press Print to print out the obtained data Press Save to save the results E Si S2 53 54 S5 C1 C2 C3 C4 C5 D1 D2 D3 D4 DS Sport valuable merits S1 Activity S2 Purposefulness 3 Self reliance S4 Stress resistance S5 Self regulation Before nosologic changes C1 introspection C2 Unsolvable dreams C3 Amotivational anxiety C4 Deterioration of efficiency C5 Irascbility irritability Dysadaptation states D1 Troubled hypohondriacal states D2 Tendency to solitude D3 Vege
24. isible peculiarities of the subject s glow have not disappeared from the screen Switch to the monotonous palette Nau pWN Make sure that the bright blue dots do not fill the entire or almost entire glow area 8 If necessary repeat the procedure Naturally the procedure of selecting the parameters is done only once using several samples of GDV images of fingers and GDV images of the test object captured with the given GDV Camera Several parameters of noise filtering are offered in the program Press la a a a e Sport Smith 2011_03_13 16 25 GDV mages without filter GDV images with filter Noise filter parameters is Abs noise level 30 Rel noise level 100 Base intensity Threshold Min fragment area 30 Work radius 0 Indude inner ellipse glow V Intensity correction BT JE wehout teria JE without teria PE wihout erat JE without ter Calibration Print GDV mages Capture GDV mages Load GDV mages lt lt Back Next gt gt Absolute noise level removal of all the image points whose intensity is lower or equal to the given noise level It is recommended to select the value individually for each session of recording within the limits from 10 to 60 Relative noise level the program automatically selects absolute noise level on the basis of the given percent of the value of base intensity This algorithm selects
25. mum 6266 KG C GDvData smith Without fiter 1R bmp 7 The video camera performance error is not the only noise contribution to GDV images It also may be dirt on the work surface of the instrument It may result in separate bright spots or fragments that also should be filtered As a result noise filtration of GDV images is carried out in two stages First you need to remove pixels whose intensity is equal or less than a certain limit There are two ways of setting this limit 1 The limit is set directly a corresponding parameter of the program is called absolute noise level 2 The limit is determined automatically for each image by a certain characteristic of the GDV image spectrum SK Noise Smith 2011_03_13 16 25 GDV images without filter GDV images with filter Noise filter parameters r 2 Abs noise level 30 Rel noise level 100 S A 7 3 i Base intensity Threshold k B Without fiter 5R Min fragment area Mean 5 Median Work radius peak Include inner ellips Threshold 6 d Intensity correction 2 Coox cancel 6 Calibration Print GDV images Capture GDV mages Load GDV mages lt lt Back Next gt gt The latter method is regulated by the two parameters relative noise level and basic intensity A relative noise level determines the percentage of the limit value for filt
26. n in the GDV image processing programs To carry out calibration you need to press Calibration in the left lower part of the GDV images window E Pie te S pert Noise Smith 2011_03_13 16 25 GDV images without filter Calibration V The program GDV Capture will be launched in the calibration mode A more detailed description of calibration process loading or capturing GDV images see in the instruction to the GDV Capture program in section Working with program GDV Capture GDV Sport gt Working with program gt Calibration GDV Sport gt Working with program gt Group calibration Group calibration Beginning from version 2 7 0 of the GDV Capture 2 program the algorithm of obtaining calibration data was considerably improved while the format of saving information and the set of the calculated parameters were not changed Therefore if you process GDV images that were previously recorded by an earlier version of the GDV Capture 2 earlier than 2 7 0 in the new versions of GDV Software beginning from 2010 the results will be incorrect To avoid this it is necessary to recalculate calibration data in the latest version of the GDV Capture 2 program and to save these data into GDV image files You can do it in two ways 1 For one selected series of a single subject 1 Load the sbj file of the subject into any program of the GDV Software package working with the ext
27. ng and saving the results GDV Sport gt Introduction gt Purpose of the program GDV Sport gt Introduction gt System requirements System requirements The program can be operated in the following Microsoft Windows operating systems e Windows 2000 e Windows XP e Windows Vista e Windows 7 Recommended computer configuration Recommended computer configuration e 32 bit x86 or 64 bit x64 processor with a clock speed of 1 gigahertz GHz or higher e 1 gigabyte GB 32 bit system or 2 GB 64 bit system memory RAM e 16 gigabytes GB 32 bit system or 20 GB 64 bit system hard disk space e graphic device DirectX 9 or higher Training level of a user Training level of a user e user should have skills of work with Windows OS GDV Sport gt Introduction gt System requirements GDV Sport gt Working with program Working with program General description of the program Adding an entry of a new subject data Loading GDV images Capturing GDV images Calibration Group calibration Noise filtration Pseudocoloring modes Correction of the center and ellipse for the GDV image of finger GDV Image menu Data table Summary Additional information Printing out GDV images Saving printed documents GDV Sport gt Working with program GDV Sport gt Working with program gt General description of the program General description of the program The interface of the GDV Sport is arranged as
28. o be open You can edit the list using the following buttons s A enables to add to the list the files with sbj extension from the selected folder on the disk U x deletes all selected files with sbj extension from the list B deletes all files with sbj extension from the list Using the Folder pattern and File name pattern you can load into the list not all files but only those that meet a specific condition In these input fields you can enter any part of the folder or file name You can also use the two special symbols and means any number including 0 of any symbols means just one symbol For example you have a set of files of 10 fingers and you need to open the files with fingers of the right hand taken with filter To do it you type Filter in the Folder pattern field and type R into the File name pattern naturally you need to name the files and folders on the disk in an appropriate way Then when you scan the selected folder only the required files will be loaded into the list When you have finished selecting the parameters press OK C TTS A 7 Edit data Use the button Subject name Sex Age Capt count Remark 1 Smith male 20 2 New subject Load subject Load per list Edit data Remove from list Category GDV capture Date Without filter With filter 1 2011_03_13 16 15 4 3 2009 10 46 59 AM is loaded is loaded 2 2011_03_13 16 3 1
29. ou press the button New subject the subject s personal data window will show up CYT VI Sport File name C GDVData Subject 1 sbj Browse Personal data Name Subject 1 Sex male Birthday 13 3 1991 day month year Remark GDV Capture data GDV Capture name 2011_03_13 16 06 Date New sul Category x Edit Remark GDV mages without filter No data Capture GDV images amp Load GDV images GDV images with filter No data G Capture GDV images The file name with the sbj extension to where the subject s data will be saved is formed by the program automatically based on the subject s name and the current path to the GDV data base This path is normally selected by the user when installing the software and it is not to be changed further on However using the button you can indicate a new path to the GDV data base In the upper part of the window enter the subject s personal date name of subject in the line Name e g Smith indicate the date of birth select sex and if necessary put down your comments to this subject Button BS enables to enter or edit the date of birth using the calendar CTI Sport File name C GDVData Subject 1 sbj Browse Personal data Name Subject 1 Sex male wij Birthday 13 3 1991 day month year Remark a GDV Capture data GDV Capture name
30. ration calculated from the selected basic intensity There are 5 options of basic intensities Average an average intensity calculated by analysis of all points of image Average RMS an average intensity of all points of image plus standard intensity deviation Median a median of the image points intensities Peak the most frequently met intensity value Threshold a value exceeding the intensity peak the number of pixels containing this value is less than 1 of the total amount of image points H S T L At the second stage of filtration a list of image fragments is built groups of glow pixels situated nearby the principle of 8 connectedness is used two points are neighboring if their coordinate values have not more than one unit difference i e the neighboring of the given points are those being in one of the eight nearby positions For each fragment the area is calculated i e the number of pixels in it Then you need to remove from the GDV image all fragments whose area is smaller than the specified one It is regulated by the parameter minimal fragment area The value of this parameter is 10 by default and usually does not require any changes For the convenience of processing GDV images of liquids that may splash during a discharge and also if there is edge flare external lighting another parameter has been introduced the working radius If this parameter is non zero all pixels whose distance to the glow
31. ro with analog videocamera FTDI 13 6001 110310 Image size 370 x 285 Energy level 1 Image transformation No transformation Tun pa nos Static GDV images bmp Parameter name Parameter value 6 Press Calculate D Su Te Eeo C AD SS SSS E amanen So lB mania 7 Then press Save calibration results the GDV Capture 2 program will close Value Date and time of calibration 6 4 2011 12 09 29 PM Date and time of GDV images capture 6 4 2011 12 07 37 PM GDV device model GDV Camera Pro with analog videocamera FTDI 13 6001 110310 Path to GDV images files C GDVData Calibration Radius error 0 01 should be less then 2 00 Area error 1 46 should be less then 5 00 Intensity error 1 21 should be less then 5 00 Filename Date and time of capture Inner radius irregularity Area error Intensity error 0001 bmp 6 4 2011 12 07 09PM___0 56 tolerance 4 00 6 82 tolerance 15 00 1 75 tolerance 8 00 0002 bmp 6 4 201112 07 12PM 0 55 tolerance 4 00 7 08 tolerance 15 00 1 99 tolerance 8 00 Value Date and time of calibration 6 4 2011 12 09 29 PM Date and time of GDV mages capture 6 4 2011 12 07 37 PM GDV device model GDV Camera Pro with analog videocamera FTDI 13 6001 110310 Path to GDV images files C GDVData Calibration Radius error 0 01 should be less then 2 00 Area e
32. rror 1 46 should be less then 5 00 Intensity error Filename Date and time of capture 0001 bmp 6 4 2011 12 07 09PM 0 5 75 tolerance 8 00 0002 bmp 6 4 2011 12 07 12PM 0 1 99 tolerance 8 00 8 The window with a list of GDV images into which the renewed calibration data needed to be recorded will open Press Add all files from selected folder to select one or several file from any folder or press Load from folder to load all GDV images from the selected folder the folder is scanned recursively E Folder pattern File name pattern Q x Type of files in thelist Data files sbj NS File name Number of files in the list 0 Type of filesin thelist Data files sbj File name C GDVData GDVEnergyField Crystal sbj C GDVData GDVEnergyField Fisher sbj C GDVData GDVEnergyField Luz sbj C GDVData GDVEnergyField Rooney sbj C GDVData GDVEnergyField Smith sbj Number of files in the list 0 Calibrat 10 Save the data with the new calibration GDV Sport gt Working with program gt Group calibration GDV Sport gt Working with program gt Noise filtration Noise filtration The window Noise filter parameters is opened using the button in the upper part of the Dynamic GDV images page a x Seats AE GDV images without filter GDV images with filter Smith 2011_03_13 16
33. s levels of organization and complexity Mental self regulation is one of the levels of regulating the activity of theses systems expressing the specific character of mental properties of reflection and modeling the reality which realize it including the subject s reflections Before nosologic changes Introspection observation of one s own mental life going deep into one s own thoughts Unsolvable dreams an effort to find a solution of unsolvable problems at subconscientious level during sleep Unmotivational anxiety a symptom of psychoemotional disorder Deterioration of efficiency a decrease of an ability to perform expedient activities at the given level of efficiency during a certain time period Irascibility irritability a non controlled inadequate psychoemotional subject s response to exogenous irritants Dysadaptation states Troubled hypohondriacal states a depressive psychological disorder with obsessive and overvalued alarms referred to one s health Tendency to solitude a psychoemotional state characterizing a state of depression both endogenous without any evident reasons and reactive response to psychotraumatic reaction Vegetative dysfunction it is combined with emotional disorders and expressed in vegetative manifestations giddiness sweating chill shivering arterial pressure variations lack of air Energy deficiency state states indicate insufficient energy supply of funct
34. t GDV capture data is not added In the upper right part of the page Subject list there is the menu of the program When you click on the button the menu will appear with a list of all pages where you can arbitrary switch to other pages of the program The current page is checked you can choose another one with the left mouse button but you need to consider that part of pages will be available only after the loading or processing of the GDV images You can switch between pages during work using buttons Previous and Next or in the lower right part of the page Subject list in the menu Page inte Tport Next Previous Welcome to the program Add new subject entry or v Subject list load data from disk GDV images Data table Summary Additional Info New subject Load subject Load per list Remove from list GDV capture data is not added If GDV images are loaded there is an opportunity to switch between necessary pages in the menu Page If you press the button a menu will show up with a list of possible actions on this page including both operations common to all pages of the program New subject Load subject s data etc and specific operations for the current working window For example Group calibration this option allows recalibration of gdv images which were calibrated earlier with new algorithm of calibration Pinte Tport temove capt
35. t there will show up the entries about the Before the subject s name and names of captures there are checkmarks to check uncheck the processing of a single subject or capture It means that you can process view not all loaded ones but only selected sets of captures and not only loaded subjects but only selected ones To check uncheck you need to double click the left mouse button C TTS A 7 To work with the upper list the following buttons are provided below the list Subject name Sex Age Capt count Remark 1 Smith male 20 2 New subject Load subject Load per list Edit data Remove from list Category GDV capture Date Without filter With filter 1 2011_03_13 16 15 4 3 2009 10 46 59 AM is loaded is loaded 2 2011_03_13 16 3 13 2011 4 18 26 PM isn t loaded isn t load w p The button Load subject enables to load information about the subject from the previously saved file The Load per list button enables to for a list of files of subjects and to load this data into the program from the window Files list composing File name pattern Q x Type of files in thelist Data files sbj File name C GDVData Fisher sbj C GDVData Smith sbj C GDVData Crystal sbj C GDVData Luz sbj C GDVData Rooney sbj Number of files in the list 5 The window shows a list of files with extension sbj which need t
36. tative dysfunction D4 Energy deficiency state D5 Necessity for check up Press the button Go to the subjects page to return to the page with the List of subjects GDV Sport gt Working with program gt Summary GDV Sport gt Working with program gt Additional information Additional information On the last page it is possible to correct or add the additional comments to the Subject or Capture This information will be saved in sbj file r Smith Subject Information GDV Capture Information 12011 03 13 16 25 GDV Sport gt Working with program gt Additional information GDV Sport gt Working with program gt Printing out GDV images Print GDV images The program makes it possible to print out the loaded GDV images with sector division Press on the GDV image loading page Before printing the program will open the preview window from where the image might be printed or saved cose La Gisa x b gt eau Smith 2011_03_13 16 25 GDV im ages without filter There are several buttons in the tool bar of this window 60 Close closes the preview window Print switches to window Print setup followed by printing lt lt gt gt enables to view the previous page and next one I lt lt enables to view the first page and the last one Safe to file Enhanced Metafile extension
37. technical state of the GDV camera and for the analysis of glow area of test object which is necessary for proceeding in different programs of GDV Software You need to perform calibration in the following cases s Before starting to work with a new GDV device e When you connect the GDV device to a computer that has not been used for calibration e After switching from the AC DC adapter 110 240V 12V to the battery and back e When you bring the GDV device from one room to another or outdoors and back e When the climatic conditions in the room where you capture GDV images change if the temperature difference is more than 5 C or humidity difference is more than 10 e In presence of an outer electromagnetic radiation source near to the GDV device or when the GDV device is taken to a place with normal or low electromagnetic noise level from a place with high electromagnetic noise level e Also once in 6 months The calibration process begins with capturing or loading GDV images of the test object You will need no less than 10 GDV images of the test object for processing the first 5 GDV images should be recaptured Before processing you need to save all GDV images It is important to make sure that GDV images of the test object have no defects for example due to misplacement of the test object illumination or dusty inner circle etc Such defects can distort calibration data which will make it impossible to obtain reliable informatio
38. the name of the group is not obligatory you need to press Cancel C TTS A Category All selected categories Sort criterio score Descending X Capture Capture S Energetic Stress as EE date category potential level 1 Smith 2011_03_13 16 4 3 2009 10 46 59 AM 3 21 7 Enter group name swimming Print GDV Sport gt Working with program gt Data table GDV Sport gt Working with program gt Summary Summary The page Summary contains a table where the qualities of the following categories are mentioned Sport valuable merits Activity a subject s ability to change the situation or an attitude to it in the absence of the definite prognosis of its results but continuously taking into account the degree of its efficiency Purposefulness a psychoemotional state characterizing readiness and emotional motivation in reaching the goal Self reliance a volitional quality that shows in calm perception of his own abilities and advantages by the subject Stress resistance the constellation of personal qualities which enable the subject to stand high intellectual volitional and emotional overloadings due to peculiarities of his professional activity without harmful after effects for himself and other people Self regulation regulation from Latin regulare to bring to order to adjust expedient functioning of living systems of variou
39. turing GDV images On page there is the button that makes it possible to capture GDV images from any program of the GDV Software package r 3K Moise Smith 2011_03_13 16 25 GDV images without filter Calibration lt lt Back N Load GDV mages The GDV image capture process is carried out in the GDV Capture program When you save the captured GDV images in this program the following structure of folders on the disk will be automatically created lt Subject 1 gt sbj lt Subject 1 gt GDV Images lt Name of capture 1 gt GDV images without filter 1R bmp 2R bmp 3R bmp GDV images with filter 1R bmp 2R bmp 3R bmp The lines containing in lt gt will be replaced by data input by the operator when creating the subject s account and during GDV capturing Until the GDV Capture is closed the work of the program from where the call is made will be blocked After saving the captured GDV images and closing the GDV Capture program the images will automatically load to the GDV images window The protocol of capturing GDV images is described in details in the instruction to the GDV Capture program GDV Sport gt Working with program gt Capturing GDV images GDV Sport gt Working with program gt Calibration Calibration Calibration of GDV devices is the process of registration of number of GDV images of test object and processing of the images with the purposes of control of
40. ure Add new subject entry or load data from disk New subject Load subject Load per list Remove from list GDV capture data is not added New subject Load subject data Load per list Last calibration info Calibration Group calibration Close the program TTS Tport Subject name Sex Age Cap 1 Smith male 22 Gan a ee a Gee Category GDV capture Date 1 Capture2 4 3 2009 10 46 59 AM New subject Edit subject data Remove subject from list Load subject data Load per list Save changes Clear list Add capture Edit capture data Remove capture Last calibration info Calibration Close the program a H Add capture Edit data Edit capture data CTs port GDV Capture data GDV Capture name Capture 2 Date 4 3 2009 10 46 59 AM Category Remark ____ GDV images without filter C GDVData smith Without filter Catego GDV images with filter C GDVData Smith With filter 9 Capture GDV images Load GDV images Capture GDV images SVT V7 Sport Noise Smith Capture 2 Go to subject s page New subject GDV mages without filter GDV images with filter Save changes Capture GDV images Load GDV images Print GDV images Recalculate all Last calibration info Calibration

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual Manuel De L`utilisateur Vacuum  XD360U-EST WD380U-EST  Softwarehandbuch für NAV - PNF 35 - a  Philips DVDR3570H User Guide Manual - DVDPlayer  Frigidaire FRS184YS2 Product Specifications Sheet  BK MIKRO9  

Copyright © All rights reserved.
Failed to retrieve file