Home
E2 Humidistat - On Time Mall
Contents
1. 1 Removable terminal block for wire connections TO MOUNT THE UNIT This product is engineered to give you years of satisfactory service Here are a few precautions Do not allow excess humidification Excess humidity can cause condensation and enable mold and mildew growth e e Do not tamper with the unit s internal components HUMIDIFIER The unit contains no user serviceable parts CONTROL MODULE e The contents of this manual may not be reproduced without the permission of the manufacturer NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice SPECIFICATIONS TYPE DESCRIPTION WIRING TO DS 15 RS 15 CS 15 DS 35 ees pad a RS 35 CS 35 ELITE STEAM HUMIDIFIER HxWxD 3 3 x 3 3 x 0 8 in Weight 95 4 g 3 4 ounces NOTES Temperature unit F C To remove the humidistat from the base squeeze OUTDOOR TEMP SENSOR Temperature operating 32 F to 99 F the louvered base at the top and bottom NOT USED IN MANUAL MODE range 0 C to 37 C e To remove the humidistat from the wall lift up on Temperature resolution 2 F 1 C the humidistat and pivot top away from wall Humidity range 10 to 90 Before wall mounting please remove the gasket Humidity resolution 1 e Before return air duct mounting please remove the breakout piece Remove terminal block for wiring eG TEO VOl AG e If return air duct mounting route wires between TEC
2. E e If in air intake place 1 foot or closer to outside wall TO USE THE UNIT GENERA lire OPN N Place at least 6 higher than possible snow age Do not route sensor wire near high voltage wires Press to select OFF MANUAL or AUTO mode if E2 Humidistat TO CONNECT THE UNIT outdoor sensor is connected INTRODUCTION e OFF mode The humidifier is turned off i WIRING TO 24V HUMIDIFIER FOR CONSTANT DISPLAY e MANUAL mode The E2 will work to maintain the an bas ror selecting ine Cee ee E2 RE OF single humidity selected You can set your desired Humidistat A professional technician should install the z a re humidity level by pressing A or V The humidifier unit Z i OUTDOOR TEMP SENSOR will turn ON or OFF according to your manual setting L ronu aens The humidifier will operate when the measured relative humidity falls more than 2 below the set point Humidity will have to be lowered when weather NOTE Please keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and Tp LENO VALVE is colder or if condensation is suspected warnings you should know about Suggested Setting Outdoor Temperatures OVE RVI EW aaa 727 58 24 V TRANSFORMER 1 5 E0 2 9 C HUMIDIFIER 24V A TUNE OOERAION 20 F0 23 25 FO 18 C WIRING TO 24V BYPASS HUMIDIFIER 30 F1 0 T2 1 35 F20 U 8 e r 40 F30 a ESAE e AUTO mode The E2 will automaticall
3. HNICAL SUPPORT humidistat and base General Filters Inc Tel 248 476 5100 43800 Grand River www generalaire com Mount the sensor outside the house Novi MI 48375 USA Do not mount on South side of the house or in direct sunlight e Place at least 4 feet away from any exhaust vent FORM NO 13144 REV D
4. MANUAL mode e AREO feniperanure Mtl e To toggle between indoor outdoor temperature 7 Wall mount cover Squeeze top bottom to open 24V OUTPUT FROM HUMIDIFIER RED WIRES OR 8 H midit index chart 727 58 24 V TRANSFORMER SWITCHED WITH FURNACE OR ae u y OR 24 VAC POWER SUPP LY SWITCHED WITH FURNACE and indoor humidity Press 9 Outdoor temperature reading is displayed e To change the temperature unit Press C F 10 Temperature humidity setting is displayed WIRING TO DS 20 ELITE DUCT STEAM HUMIDIFIER e To set the temperature humidity offset in 11 Temperature humidity offset is displayed ic di T 12 Indoor temperature humidity reading is displayed AE EON MANUAE idk loge died aay v a 13 M W Increase decrease setting enter Pe ANEU ay and ann wn INE l b rmidit Temaer ure olser sellin 2S OUTDOOR TEMP SENSOR ak temperature or humidity reading ul i pem mone 2 Use amp or W to change the setting 3 to 3 3 Press and V simultaneously or wait 5 seconds to confirm and move onto the next setting FIELD SUPPLIED HUMIDIFIER PO ZRODE ae pills e Loor Hi will flash on the display when INSTALLED x MEASUREMENT HI POWER SUPPLY ad Indoor temp Below 0 C Above 32 F 99 F 37 C Outdoor temp Below 40 C Above 50 C 40 F 122 F Humidity Below 10 Above 90 e f power is lost current settings are retained o 12500 AIR PRESSURE SWITCH PRECAUTIONS
5. y raise the EER EE humidity as the outdoor temperature increases This NOT USED IN MANUAL MODE provides the highest possible humidity The E2 will L eronsa automatically lower the humidity as temperatures drop This minimizes the risk of condensation on cold PRENESE surfaces like windows You can adjust the Auto SOLENOID VALVE Humidity Index Set Point from 0 low to 10 high by oi pressing A or V The Humidity Index is based on the outdoor temperature and indoor humidity The OOA W OR 24 VAC POWER SUPPLY 1 Operation modes SMUTS HED VITH FURNACE OPERATION humidifier will switch ON OFF according to the 2 Moisture is being added into the environment calculated auto humidity index set point Lower Index 3 Humidity temperature reading WIRING TO 1137 1000 POWER HUMIDIFIER settings are for older homes with less insulation and vapor barriers Higher Index settings are for newer homes with complete vapor barriers triple pane gt 5 Sao windows and high R value insulation If condensation occurs reduce Index setting by 2 points until n Zz n a 193v T C 4 Toggle between OFF MANUAL and AUTO modes if outdoor sensor is connected 5 Toggle between indoor humidity and indoor PASEET T condensation stops 4 outdoor temperature displays if outdoor sensor is NOT USED IN MANUAL MODE NOTE If the outdoor temperature sensor fails ae i aac a i HUMIDIFER CONTROL LEADS flashes and the unit will default to
Download Pdf Manuals
Related Search
Related Contents
目 次 ステップ 1:オンライン申請を利用する前にすること ステップ2 SERVICE MANUAL REFRIGERATION MCL ACC-F052 screen protector Neptune APFC RM Series Manual User Manual of - Panda Vending Manuale de instruzioni Bedienungsanleitung カタログ - Kodak Electrónica de Potencia (11694) - Facultad de Ciencias Químicas e Xantech RS2321X8 User's Manual Copyright © All rights reserved.
Failed to retrieve file