AR200 Automatic Digital Refractometer User Guide

image

Contents

1. To perform calibration of any additional points follow the procedure outlined in steps A through G making sure that you always start with the lowest refractive index sample and moving up to the highest refractive index sample Clean and dry the prism surface and the AR200 will be ready to take readings 11 1 CALIBRATION OILS The recommended Extended Precision Standard Calibration Oils are manufactured by Cargille Labs Cedar Grove NJ 07009 1289 USA Phone 201 239 6633 To our knowledge they are the only domestic USA source of extended precision standard calibration oils with six significant figures in index The characteristics of these oils are NIST traceable Stated accuracy at 0 00005 nD shelf life in years Temperature coefficients TC are guaranteed at their specified reference temperatures usually 20 or 25 C 12 0 CHANNELS 12 1 12 2 CHANNEL 1 ICUMSA BRIX The AR200 is preprogrammed at the factory with channel 1 to read Sucrose or Brix scale per the International Commission for Uniform Methods of Sugar Analysis ICUMSA Temperature Corrected TC readings in channel 1 are valid for Brix Solutions only CHANNEL 2 4 USER PROGRAMABLE User programmable scales or custom channels may be programmed at the factory or by using the optional IR communications package Custom channels allow the user to use measurments specific to a solution to measure that solution and deliver readings with temp
2. AR ZO Refractometer User s Guide Reichert TECHNOLOGIES Analytical Instruments Reichert AR200 Instruction Manual Table of Contents Page 1 0 Introduction 3 2 0 Specifications 4 3 0 Environmental Conditions 5 4 0 Care and Cleaning 5 4 1 Care of Prism Surface 5 5 0 Instrument Features 6 6 0 Automatic Temperature Compensation 7 6 1 Temperature coefficient and correction calculations 7 7 0 Installation Procedure 7 7 1 Set Up 8 8 0 Sample Reading 10 9 0 Menu Options 11 10 0 Daily Single Point Calibration 12 11 0 Multipoint Calibration 13 11 1 Calibration Oils 14 12 0 Channels 15 12 1 Channel 1 Brix Sucrose per ICUMSA 15 12 2 Channels 2 4 User Programmable 15 13 0 Accessories 15 Page 2 1 0 INTRODUCTION Congratulations on your purchase of the Reichert AR200 Digital Handheld Refractometer This manual describes the proper operation and care of this state of the art instrument The AR200 is capable of measuring Solids Brix Solids TC Brix Temperature Compensated Refractive Index and Refractive Index TC temperature Compensated per ICUMSA Sucrose temperature Coefficient Although it s main purpose is to aid quality control personnel in Food and Beverage applications it s advanced features make it a well suited instrument widely used for Medical Pharmaceutical Industrial Fluids Chemical and Petrochemical Industries An AR200 has the capability to measure Refractive Index nD of liquid solutions to
3. 10 C 45 C Max Relative Humidity 80 for temperatures to 31 C decreasing linearly to 50 relative humidity at 40 C Pollution Degree 2 Altitude up to 2 000 meters 4 0 CARE AND CLEANING 4 The Reichert AR200 is a precision optical instrument The prism surface and well should be cleaned immediately after use The interior components are protected from dust spills and other damage The stainless steel well and prism assembly is sealed with corrosion resistant epoxy All non optical components can be cleaned with soap and water or methanol Using strong solvents such as N N Dimethylformamide or N N Nimethylacetamide cresols phenols and other tar acids should be avoided Tetrahydrofuran or some lacquer thinners and their components can also deteriorate the prism seal over time or when applied at elevated temperatures Do not use Acetone Acetone based products or other harsh solvents when cleaning the instrument s body or it s components CARE OF PRISM SURFACE The prism surface should be cleaned immediately after use The use of strong acids or bases should not be measured with this instrument or used as cleaning agents Do not use any metal or sharp objects to clean or pry loose the prism seal or residue on the sample or well The sample should be wiped off with a moist tissue Warm water and soap is recommended for removing sucrose residue and oil based samples followed by a distilled water cleaning Remove an
4. Batteries four AAA Page 7 Page 8 7 1 SET A UP Turn the instrument over and remove the battery cover by rotating it in a counter clockwise direction Install the four AAA batteries in the direction indicated Reinstall the battery cover and turn instrument over Place the instrument on a solid surface in an environment where the temperature is stable Be sure to keep instrument away from heat or air conditioning vents which can cause drafts and affect the temperature stability Allow the instrument time to reach room temperature Turn the AR200 on by pressing the MENU key The title screen will appear followed by instructions to apply sample and press read DO NOT apply sample or press read at this time Reichert AR200 Ver X XX Select desired Reading Mode by pressing MENU key again to enter menu options Exit Menu Use READ Up CAL Down keys to advance through mode options to Reading Mode press the MENU Return key when you see the following screen Reading Mode le d Use the UP or DOWN keys to advance through Reading options select Brix TC mode for this exercise by highlighting and pressing the RETURN MENU key Brix TC Solids Temperature Compensated nD Refractive Index Brix Solids nD TC Refractive Index Temperature Compensated Brix TC ia 4 You will then exit
5. the Refractive Index displayed value reference section 6 1 9 0 MENU OPTIONS A Exit Menu Pressing the MENU key when this is displayed will exit the menu mode Calibration Displays options of 1 Set water Pressing MENU will prompt to Apply Water and then CAL or MENU key to cancel 2 Span 1 40229 Press MENU will prompt to Apply 1 40229 NIST certified calibration oil and to press CAL or MENU key to cancel 3 Span 1 51416 Press MENU will prompt to Apply 1 51416 NIST certified calibration oil and to press CAL or MENU key to cancel 4 Add Delete Edit When selecting any of these modes a Warning will appear Incorrect use of this function can corrupt the instrument Contact the Technical Support Group for a complete explanation if this function is to be used 5 Exit Press MENU to exit the calibration options mode Contrast Press the MENU key to enter and the Up Down keys to adjust display contrast IR Linkup To use this function the optional Docking Station 13951000 must be used This feature allows for downloading of stored values up to 225 of the most current readings and up to 5 point current calibration log Set Clock Allows for setting of the time in 12 hour am pm or 24 hour military and the date in MDY format Select Channel This feature is visible only when at least one custom channel has been added to the AR200 Ente
6. the menu screen and return to the main screen Press CAL key and follow instructions to add sample add Distilled Water as the sample Enough distilled water should be added to cover the prism surface approximately 3 drops Allow sample to temperature equilibrate to prism well Press CAL key again Observe the display for message indicating Set Point Cal Successful Apply water CAL Calibration MENU Cancel Set point cal successful Press the READ key and note the value on the display which should be 0 0 Brix TC 20 0 C Please note that the 0 0 Brix TC reading can vary by 0 1 which is the acceptable tolerance of the AR200 0 0 Brix TC 20 0 C Page 9 8 0 Page 10 ee READING Clean and dry the prism and well with a soft wipe which will leave no residue and recommended cleaning agents soap and warm water Methanol or Isopropyl Alcohol followed by distilled water B Add enough of the sample to cover prism surface and allow adequate time for sample to temperature equilibrate to prism well C Press READ D Note value on display 1 3330 nD TC 20 0 C E Reference directions in Set Up section to switch between the four modes of measurement 7 nD 2 Brix 3 nD TC 4 Brix TC F Compare reading to known value Note any difference in well temperature from sample reference temperature and adjust refractive index reading mathematically from
7. a precision of 0 0001 or Solids Brix to 0 1 with a range of 1 3300 to 1 5600nD and 0 to 95 Solids Brix Please note that an AR200 Refractometer is a high precision optical instrument It is absolutely necessary to properly maintain the instrument to obtain the best possible accuracy This includes thoroughly cleaning the prism and well after each sample and routinely calibrating the instrument Always store the instrument with the well clean and dry Page 3 2 0 SPECIFICATIONS Page 4 The Reichert AR200 operates on four AAA batteries The instrument is capable of 3000 readings on a set of batteries and has auto off sleep mode after 30 seconds of inactivity and low battery detection Three Key Operation CAL READ and MENU with on screen prompts Illumination 589 nm LED Range 1 3300 to 1 5600 Refractive Index nD 589nm Sodium D line 0 to 95 Solids Brix Sucrose per ICUMSA in Channel 1 User definable in channels 2 4 Readability 0 0001 nD 0 1 Solids 0 1 C Temperature Accuracy 0 0001nD 0 1 Solids Brix 0 2 C Temperature Temperature Compensation Range 15 40 C 59 104 F per ICUMSA in Channel 1 user definable in custom channels Prism Assembly Sapphire Prism sealed to Stainless Steel Well with solvent resistant epoxy Dimensions 18cm x 9cm x 3 5cm 7 L x 3 75 W x 1 37 D Weight 410g 3 0 ENVIROMENTAL CONDITIONS Temperature Range
8. ble to contact the technical support group before using this feature The 3 4 and 5 point calibrations is made available to allow the user to precisely calibrate the instrument to certified standards near the refractive index range where the measurements are being made Reference the procedure below to perform the multipoint calibration Always clean and dry the prism surface between the application of samples and be sure to proceed starting from the distilled water up to the sample with the highest refractive index Turn the AR200 on by pressing the MENU key Press the MENU key again after the startup screen appears to enter the Menu Press the UP key until Calibration is read on the display and press the MENU key When Set Water appears press the MENU key and follow the instructions on the display to add water and press the CAL key Continue calibration process by repeating steps A through C and proceed to the next step Page 13 Page 14 When Set Water appears press the UP key several times to advance to the Span 1 51416 value this value is given as an example and may be different although close to the value on your AR200 Press the MENU key other points exist Span 1 51416 Follow the on screen instructions to apply 1 51416 sample allow time for the sample to equilibrate and press CAL key Apply 1 51416 CAL Calibration MENU Cancel
9. erature correction factors that relate to that solution 13 0 ACCESSORIES Catalog No 13951000 IR Communications Package The IR Communications Package includes a docking station and the software required to connect the AR200 to your PC It is useful for down loading stored readings up to 225 of the most recent readings and up to 5 point current calibration log Catalog No 13K41330 Calibration Oil 1 51432 Catalog No 13K41340 Calibration Oil 1 40229 Catalog No 13K41350 Calibration Oil 1 45755 Catalog No 13K41360 Calibration Oil 1 48989 Above values may vary due to supplier of oil Page 15 Reichert Analytical Instruments Reichert Inc 3362 Walden Ave Depew NY 14043 USA Toll Free 888 849 8955 Phone 716 686 4500 email info reichert com www reichert com Reichert GmbH Hubertusstrasse 4 D 82229 Seefeld Germany Tel 49 8152 993530 ISO 9001 Certified 13950000 100 Rev F Page 16
10. peratures As an example Samples taken at 15 C 40 C are corrected to a reference temperature reading of 20 C Temperature correction or control is necessary because refractive index varies inversely with temperature as temperature of sample rises refractive index falls and so as sample temperature drops refractive index will rise This feature can be used in lieu of controlling the temperature of the prism and sample It is however necessary to Allow Samples to Temperature Equilibrate sample must reach same temperature as prism surface so that the AR200 can properly correct for temperature The automatic temperature compensation mode built into the AR200 is based on the temperature coefficients AnD A C of sucrose per the ICUMSA scales When readings are taken in Index TC Refractive Index Temperature Compensated mode the reading is only valid for Sucrose Brix solutions 6 1 Temperature Coefficient Calculations non Sucrose samples Should you need to temperature correct refractive index values for samples other than those that are sucrose based Please download Temperature Coefficient Calculation and Temperature Correction at www reichert com Analytical Applications or contact Reichert Analytical Technical Support 716 686 4500 7 0 INSTALLATION PROCEDURE A Unpack instrument from carton Retain packing material for future storage protection shipping B Please note the following accessories Instruction Manual
11. ring this feature allows the operator to switch between available channels scales Reading Mode Allows for changing between nD nD TC Brix or Brix TC reading modes TC modes are Temperature Compensated based upon Sucrose data in channel 1 Page 11 10 0 DAILY SINGLE POINT CALIBRATION Page 12 1 2 Turn the instrument on by pressing the CAL key Atthe displayed message to apply sample press the Cal key again Exit Menu d Apply Distilled Water sample and Press the CAL key Apply water CAL Calibration MENU Cancel Set point cal successful message will appear if the AR200 is functioning properly Set point cal successful 10 0 DP DO MULTIPOINT CALIBRATION The AR200 can be calibrated with up to 5 points using distilled water and 4 user definable points note that these are set atthe factory to match available NIST certified standards Performing a 2 point calibration will provide the required accuracy needed using distilled water and a high refractive index NIST certified standard The AR200 has 3 points available as points that can be chosen through the calibration mode menu Two additional points are available and modification ofthe existing points can also be done through the Aad Delete Edit option in the calibration menu When entering this screen a message will appear Warning Incorrect use of this function can corrupt your instrument It is advisa
12. y remaining moisture with a dry tissue Page 5 5 0 INSTRUMENT FEATURES Refer to the features listed below Page 6 1 Instrument Display Digitally displays measurement values operator instructions and error messages Keypad Controls All three controls are soft touch membrane keys CAL down READ up MENU return These keys serve a dual purpose as function keys and also facilitate moving the displayed cursor highlighter when selecting the many available options CAL Prompts the user to perform a water calibration Also is used as the Down key to allow scrolling when changing menu options or values READ Will read the sample in the well Also is used as the Up key to scroll through choices when changing menu options and values MENU Allows entry to the menu options of the AR200 The menu key also functions as Enter Exit or Cancel depending on the menu screen and or the on screen instructions Sample Well The sample well is made of Stainless Steel with a Sapphire Prism mounted to its center When a sample is placed on the prism face it is important that the sample cover the entire prism surface to attain an accurate reading IR Window Located on the bottom of the AR200 it is used to communicate with your PC when cradled in the optional docking station 6 0 AUTOMATIC TEMPERATURE COMPENSATION Automatic temperature compensation corrects readings overarange oftem