Home

Installation Guide

image

Contents

1. 1 2 Piscatus3D modes Piscatus3D is available in two different modes Inshore Pro and Deepsea Pro It is important to understand the differences between these modes and how the modes overlap Please refer the table below to compare the available modes Inshore Pro produces the highest detail of the seafloor because of its finer data resolution and depth accuracy Deepsea Pro is a more efficient system by storing less data it is able to maintaining bigger map sizes in Piscatus Version 5 Installation Guide 7 deeper waters For most vessels Inshore Pro is the current choice as it can give higher detail in shallow water but still stores data down to 3200 metres Deepsea Pro is recommend for vessels working almost constantly over 1000 metres or require 3D maps larger than 20 Nm Feature Inshore Pro Deepsea Pro Data resolution 2 4 metres 20 metres Depth accuracy 0 1 metres 1 metre inimum depth O metres O metres aximum depth 3200 metres 32000 metres inimum map size 1Nm 5 Nm aximum map size 20Nm 60 Nm Best performance lt 1000 metres gt 1000 metres lt 1000 metres High detail Good detail gt 1000 metres Small maps detail same High detail larger maps as Deepsea Pro 1 3 How Piscatus3D works There are five main software elements that make Piscatus3D work These are SMISealog Shared Memory SeaDBLog Firebird Database Server Piscatus3D Figure 1 over the
2. From Line allows the user to set the start point in the simulation file based on its line number The simulation will start from this point each time the Start SIM button is clicked Continue allows the user to stop the simulation and continue from where it stopped The simulation will start from where it was stopped when the Start SIM button is clicked Simulation output options These options allow the user to control the processing and output of data There are three options that are self descriptive They are used for simulations where data is being sent to another computer device or comm port Default Process and don t send NMEA to output comm port Simulation comm output options These options allow the user to control the flow of data being sent out comm ports These are used for simulations where data is being sent to another computer device or comm port Default Out GP and SD to same port 34 Piscatus Version 5 Installation Guide 4 4 4 Playing preset simulations SMISealog is installed with three built in simulations These are useful for Piscatus3D dealers for show room presentations and other situations where the system must be viewed in operation but no real data is available Preset simulations are available through the SMISealog Control Panel window under the NMEA Processing and Preset SIMs tab Simulations are started by selecting one of the thre
3. DATA ad 10 15 COMPUTER SPEGIFICATIONS issan rece cirits do ec a sh 10 2 0 INSTALLATION INFORMATION sscsssssscsssssssssessssssececsssesessssssssessssesessssececessssesessseseesenee 12 ZN TALLA ONPE o ed aos al 12 2D INSTALLATION MEDIA co 14 23 INSTALLAMON MODE birca adios 15 3 0 SOFTWARE INSTALLATION ssssssssssssssscessssssececessesesessssesecsssssessssesecesessececessssecesssseeesens 16 SNA LN ASA e 16 3 2 RUNNING PISCATUS3D FOR THE FIRST TIME OBTAINING THE PERMIT CODE 19 4 0 CONFIGURATION OF SMISEALOG cssssssssssssssesessssssesessssesessesecesessosecessssesesessesesessesees 21 A INTRODUCTION oo 21 4 PASSING SMISCAIOG sto Dacia dates neo dead tdo edi e o 21 4 1 2 SMlSealog quick setup 22 4 1 3 Viewing SMISealog Status AD COMM PORTS ANDINMEA nimeen E E REEE 24 4 2 1 Viewing INCOMING data cocinan 24 ADD SEUNG UP CON EEA EA E ESE 25 4 2 3 Listening to incoming data 29 4 24 Sending data isinisisi 25 4 2 5 Using the automatic NMEA setup feature 26 4 2 6 Selecting NMEA settings occiso 26 4 2 7 NMEA CXQMPLES sssssssssssssssssssssssssnsssssssssesssssssssssseeessseseuinss 27 4 2 8 Primary and Secondary depth data and GUtO SWItCH vsssssssssssecssssssssnssssesesenssseesssnnsseesen 28 4 2 9 Filtering AG cesesscsscsessssssessssscsssncossssnscesesssvessscensssssesscdunsiaisesasessnsssesssutesssassasssssecesassssainacssnsnessseeasacseisit 29 4 2 10 Enabling Setup Mode to i
4. Current Tide tab This tab displays the data used to generate the tide value and when it was last updated 30 Piscatus Version 5 Installation Guide 4 3 3 Selecting a tide engine check SMISealog is able to calculate tide with three different engines The first is the Piscatus3D Tide Engine and is available worldwide with every installation of Piscatus3D There are another two tide engines available which are able to produce better tide calculations in European countries these are TotalTide and Proudman Both these tide engines must be purchased and installed separately before they can be used in SMISealog Please contact your local Piscatus3D dealer for details on obtaining a copy of these tide engines The TotalTide tide engine requires no extra settings to be selected before it begins to provide tide values to Piscatus3D But the Proudman tide engine requires you to select the data and license files which are in the Proudman installation directory 4 3 4 Setting a default tide station to always be used This feature is only available when using the Piscatus3D tide engine By default SMISealog automatically uses the closest tide station in order to calculate the current tide value The user can override this setting by manually selecting a default tide station Open the SMISealog Control Panel window and click on the Tide Adjustment tab and then the Current Tide tab 2 Inthe Tide Optio
5. Dealer Trial Full Result Demo Demo Install Install Piscatus Version 5 Installation Guide 3 0 SOFTWARE INSTALLATION 3 1 Installing Piscatus3D Note make sure you are logged on as Administrator to do the installation 1 Place the Piscatus3D installation CD in the computer s CD drive The setup program should start automatically however if Autorun is disabled on the machine you will have to start it manually To do this go to Windows Explorer and navigate to the CD drive and double click on SetupPiscatus5 exe Microsoft Windows Vista will require the setup program to be run as an administrator and will display a message to this point which you must accept to start the installation process 2 The Piscatus3D installation window will open as shown to the right Installation Urna betas gt options can be set up on the window Presos voto 118 Epa von chort Pe seman ER 1 y wenererte wmn o he Misaone P by clicking the Advanced Options tab Saag ty om apes yee T These options should not be changed FAN r y era meme cot GeForce IOO Yer gria when doing a first install as they control cast basil ran sh nace ais 4 08 muse ss which components are installed and all prom raton Lant X 7 et oina DIR LAA AL erre are required on first install Reinstalling tet oe cis a pus individual components can be helpful after install if one component is found to be faulty and must be r
6. SMlSeaLog is a stand alone program separate from Piscatus3D SMISeaLog picks out the various NMEA sentences it has been configured to recognize such as depth position hardness and roughness COG SOG and net position and writes these parametres to Shared Memory It also flags or discards errors in the incoming data such as an incorrect position from the GPS or the sounder coming offthe bottom and giving erroneous depth values Piscatus3D and SeaDBLog then both read the values from Shared Memory If C Plot Pro or SeaPlot Pro are also installed on the same computer they can access Shared Memory as well and use the parametres and values stored there SMISealog also has a tide calculation engine and calculates the tide based on GPS position and GPS date time SMISealog then places this tide value in Shared Memory to be used by Piscatus3D and SeaDBLog Tide information comes from any of three tide engines being the Piscatus3D TotalTide or Proudman tide engines Figure 1 The relationships and data flow between Piscatus3D elements SeaDBLog writes depth hardness and roughness information from Shared Memory to the Piscatus3D database file C Piscatus3D Data BATHYMETRY FDB The SeaDBLog program runs as a background Windows service called the Sealog Database SeaDBLog also creates trip logs which are exported by the Map Manager program and can be imported into the Fleet Manager program Fleet Manager is sold separately and is used by commerc
7. each source is in NMEA0183 format and up to four NMEA0183 outputs are required This unit is wired up as follows with each data source and destination being wired into the top of the unit Each source is wired to pins 2 and 7 Each destination is wired to pins 1 ground and 3 Pin 2 Pin5 lt x lt gt 3_8 38 Device 1 Device 2 Device 3 Device 4 NMEAO183 NMEA0183 NMEAO183 NMEA0183 Piscatus Version 5 Installation Guide 37 5 2 DM24 The DM24 is a more complex multiplexer designed to be used when up to four data sources are to be merged each source is in any format and up to four outputs in any format The unit is wired up as follows with each device and the DM24 being plugged into the DM22 4 Junction Box The incoming data comes into the junction box out to the DM24 where it is converted and merged back to the junction box and out an I O port standard setup I O 1 EBLO MAN 8089 zawa 9 LOVIAN y 3080 88 LOWSWN Mey 68 10V3NN Boag o 3 gt 38 Piscatus Version 5 Installation Guide 5 3 How to convert Furuno CIF to NMEA0183 with a DM24 The conversion of formats is done in the DM24 using two dip switches In the following text switch states are described as 0 or 1 where 0 represents off and 1 on Dip Switch 1 Dip Switch 2 The first thing to do is to plug the devices into the DM22 4 Junction Box The important thing here is to plug the Furuno
8. echo sounder and also keeps data within the limits of the Piscatus3D 3D system Echo sounder Depths This filter compares incoming data with recent data points and is designed to filter out erroneous data points such as a double echo It generates an average for the last x points and allows for an error of y if the new data is outside the range of y for z readings the average is reset using new data The default settings for this are X 5 Y 50and Z 10 Depth offset This setting allows you to set how far under the water line your transducer is When a depth is received from your echo sounder this distance is added Net height This filter works in the same way as the above filter but on the net height from seabed data X 3 Y 10 and Z 5 Net depth This filter works in the same way as the above filter but on the net depth below sea level X 3 Y 20 and Z 5 Cleaning level When each point is added to the database it is compared against points around it By default this is on the normal setting If you struggle with bad data from your echo sounder try the high setting Database cleaning can also be stopped by setting the cleaning level to none Piscatus Version 5 Installation Guide 29 4 2 10 Enabling Setup Mode to ignore GPS position problems SMISealog is normally configured with the vessel at the wharf Dock As the vessel is not moving SMISealog will flag the data as ha
9. receiving data for a set time and using the highest count values of received NMEA strings to select the best settings To access this automatic NM Control Pane window click the NMEA Processing ta EA setup feature open the SMISealog b and then the System tab and then click the Auto detect NMEA Settings button Before starting the automatic NMEA setup feature make ON and send for information on viewing incoming data 4 2 6 Selecting NMEA settings All data sent each line con MEA strings he NMEA da MEA strings Piscatus3D wil o Piscatus3D must be in NMEA format This format but needs to know which ones to expect This m listen for dependin WO parts a For example is SDDBS Setting the correct comm port an alker and a data type depth data has a tal done by a marine electronics technician Roughness and hardness N Furuno echo offset values that can be ente and SeaScan allows you to The Net NME equipment With these data P terrain for more effective fish system you h may need to sounders or SeaScan or RoxAnn seafloor di fferent values for the same fferences between units w units give out di correct these di type o hen da A tab has options for setting up Piscatus3D to liste iscatus3D can put your net ing There are options to se sure all marine electronic devices sending data to Piscatus3D are switched ing da
10. seabed discrimination device if present Instructions for configuring SMISealog are outlined in section 3 0 13 If you are outside New Zealand it is possible that you will be supplied an extra Back ground relief data CD inside the installation pack This installs land and seabed data for your area if available Please install this data before using Piscatus30 3 2 Running Piscatus3D for the first time obtaining the Permit Code Piscatus3D uses a dongle and a special code referred to as a Permit Code for its security and licensing If your local supplier does not have a dongle in stock a 60 day trial can be installed and used without a dongle This gives you a window of time to organise the delivery of a dongle so that your Piscatus3D system can be permanently used Please give you local supplier as much notice as possible to avoid purchasing a Piscatus3D system when no dongles are being held in stock To obtain the Permit Code to licence Piscatus3D and operate the software you need to contact Seabed Mapping and provide us with the Computer ID of the machine you are installing Piscatus3 on Piscatus Version 5 Installation Guide 19 1 The first time you run Piscatus3D after installation the Computer Identity window will open as shown below Computer Identity To register your copy of Piscatus pleare send us the identity code displayed below We will then forward back your Permit code to enter Your compute
11. the SMISealog Control Panel window and click on the Tide Adjustment tab and then the Graph tab This tab will automatically show the current tide station being used but different tide stations in the area can be viewed by selecting them from the drop down box Tide stations for other areas can also be displayed by searching for them using the lookup feature on the Lookup tab described above 4 4 Simulations 4 4 1 Recording simulation files SMISealog can be set up to record simulation files in the System tab of the NMEA processing tab These simulation files record the raw NMEA data being received by SMISealog and using the simulator in SMISealog can be played back and sent into SMISealog again 1 To start recording a simulation file open the SMISealog Control Panel window and click on the NMEA Processing tab and then the System tab 2 Inthe NMEA Log Files section tick the Record NMEA log option Optionally specify a date when you wish the recording to cease at 3 Underneath this option there is a setting that allows you to control the amount of NMEA data recorded We recommend Every line be used However for users with little hard drive space the recording of simulation files over a week or more can create some rather arge files so this frequency can be changed to conserve hard drive space 4 Recorded simulation files are stored on the hard drive in the C Piscatu
12. you are missing important data you may have to customize your NMEA or filtering settings Please check Selecting NMEA settings and Filtering Data sections of this manual for further assistance 9 Start Piscatus3D If all required data is shown in the Incoming data window start Piscatus3D Piscatus3D should detect the data and load a 3D seabed for around the boats current position when this happens the Follow boat option in the bottom left of Piscatus3 will be ticked 4 1 3 Viewing SMISealog Status The System first tab under the NMEA Processing tab of the SMISealog Control Panel window gives you a quick summary of SMISealog s current status The top section called Current Status gives you a live update of the most important data values being used by Piscatus3D All these data values and the data status readings are important for Piscatus3 to work correctly Also displayed here is the status of database ogging and trip logging The bottom section called Setup Tools gives you an option to open a virtual keyboard for users of Piscatus3B with touch screen displays This virtual keyboard can be used anywhere in Windows to enter text A user can also restore factory settings and perform an automatic MEA setup 4 2 Comm ports and NMEA 4 2 1 Viewing incoming data To view the incoming data open the SMISealog Control Panel window click the NMEA Processing tab and then Terminal t
13. 3D successfully are outlined below However for performance reasons we strongly suggest you obtain a system that encompasses the recommended requirements Recommended system requirements Intel Pentium Dual Core Processor 1 8 GHz 1024 MB of DDR RAM GeForce 6 series 256MB nVidia Video Card essential 80GB 7200 RPM Serial ATA Hard Drive Screen Resolution 1280 x 1024 Piscatus Version 5 Installation Guide 11 The installation process of Piscatus3D can be undertaken in many different ways This section will explain some of the options and help to remove any uncertainties 2 1 Installation types 1 User demo 2 Dealer demo 3 Trial installation 4 Full installation ITEM 1 User demo installation 2 Dealer demo installation DESCRIPTION The user demo version on the brochure disk will install without a dongle It will display pre loaded bathymetric data It won t record input from a sounder or GPS It can be installed on multiple computers It will expire 60 days after installation It can t be loaded back onto the same computer The dealer demo version will install from any Piscatus3D installation CD It requires the special demo dongle to run This will allow dealers and distributors to demonstrate Piscatus3D on an ongoing basis either in a showroom office or from a laptop It has the same functionality as the user demo except that it will not expire after 60 days if installed correctly and enabled
14. CIF signal into I O 2 which is the same position as Device 2 in the diagram at the start of this section Now you must set the dip switches in order to convert the signal format First take the top of the DM24 unit There are four switches on dip switch 2 set them all to 1 There are eight switches on dip switch 1 from 1 to 8 set each switch as follows 00100000 Turn the DM24 off and on to save the new settings To test the DM24 conversion turn on only the attached Furuno CIF device and watch the SMISealog Terminal window to ensure the correct format data is being received Piscatus Version 5 Installation Guide 39 dd Improve your fishing experience and results with Piscatus3 CONTACT INFORMATION Piscatus Limited Port Nelson New Zealand P 64 0 3 545 7020 F 64 0 3 545 7021 E support piscatus co nz W www piscatus co nz PISCATUS3D UPEWIGH SEAR y
15. ENSE GPS Echo Sounder Simrad ITI via multiplexer x Y NMEA 0183 Creation of marks vessel tracks Y Y Trial 60 days available Y Y Physical dongle required for permanent Vi wi installation Permanent Storage of instrument inputs including navigation and other data x Y in program database Permanent storage of marks vessel track in Es 7 program database 2 2 Installation media ITEM DESCRIPTION A Piscatus3B version 5 To install full options Classic Inshore Pro installation CD Deepsea Pro To install 60 day trial version without need for dongle B Demo installation amp Contains Piscatus3b demo installation amp promotional movie DVD background relief data Contains video presentations with audio in English C Background relief data CD 3D topography data installation CD relevant to area of customer Supplied separately with Item A above for you only Dongle USB security key Demo or Full E Installation pack Box sleeve Quickstart guide user manual installation manual Piscatus Version 5 Installation Guide 2 3 Installation model Step 1 The Disk aude Step 2 Install Type El Step 3 Demo Installed App E O Full ra A ra A Step 4 Demo Demo Trial Full License 60 day Dongle 60 day Dongle Ory Step 5 Trial Full Permit Permit Permit y y y y Step 6 User
16. Start SeaDBLog Service SMISealog has to be manually restarted via the Windows Start Menu Firebird must be started through Windows Services in the Administrative Tools section of Control Panel Piscatus Version 5 Installation Guide 35 Check data being received and processed If the bottom right light in Piscatus30 is flashing or solid red check SMISealog is receiving and processing the data correctly through the Terminal or Comms tab of the SMISealog Control Panel window When viewing incoming data check for position and depth data and data lags being issued Check Shared Memory in Piscatus3D If data is being correctly received and processed in SMISealog check that Piscatus3D is receiving this data To do this go to the Help menu and select Support System Information Click on the Shared Memory tab and click the Auto update option so it is checked The values being sent to Piscatus3D from SMISealog will be displayed Check these values against the incoming data in SMISealog to make sure they are the same 36 Piscatus Version 5 Installation Guide 5 0 USING MULTIPLEXERS Multiplexers are used to merge incoming data from multiple sources into one data stream We recommend the MX4 and DM24 data multiplexers available from Pacific Micro Systems http www pacmicro com products html 5 1 MX4 The MX4 is a simple multiplexer designed to be used when up to four data sources are to be merged
17. Version 5 0 Installation Guide PISCATUS Piscatus3D delivers a real time 3D view of the ocean floor anywhere in the world helping you to make the best decisions to catch more fish faster Version 5 0 Installation Guide Congratulations on your purchase of Piscatus3D Piscatus3D is a comprehensive 3 Dimensional fishing tool that displays in superior detail exactly what is happening underwater in real time as you fish With an interface designed by fishermen for ease of use view your underwater fishing grounds as never before Piscatus3D shows your boat the seabed the target fish and your fishing gear Built on a stable and reliable technology platform Piscatus32 automatically saves your data as you fish Piscatus30 is available in three customised applications designed specifically for your fishing operations Inshore Pro Deep Sea Pro and Piscatus3D Classic PISCATUS Piscatus Version 5 Installation Guide 8 LICENCE TERMS The Piscatus3D software the Software has not been designed as nor purports to be a navigational aid and must not be used or relied upon as such by the user The Software is supplied solely as an aid to fishing not an aid to navigation The software is supplied on the express condition that Piscatus3D Limited accepts no liability for any loss of catch failure to catch loss of life personal injury or loss or damage to any vessel or fishing gear resulting from the use o
18. ab The control on the left called Display Input is where you select the comm port you wish to view data coming in from The control to the right is a where the associated incoming data is displayed this control is black and will display lines of incoming NMEA data with white text Sometimes these lines of data will appear very quickly and must be paused in order to be read To pause the incoming data click the Pause button at the bottom of the window For example to view data coming in from comm port 3 Left click on the Comm3 option in the Display Input list When this option has been checked data from comm port 3 will be displayed on the right hand black data display area 24 Piscatus Version 5 Installation Guide 4 2 2 Setting up comm ports To set SMISealog to listen for incoming data open the SMISealog Control Panel window and click the NMEA Processing tab and then the Comms tab Comm ports can set up to listen for or to send data From the Comms tab the baud rate speed of data being sent or received can be set and whether or not incoming data should be checksum validated There are also options to completely stop start data comms and database logging Note data cannot be read and sent from the same comm port In order to read and send data you must have a minimum of two available comm ports Setting the correct comm port and NMEA settings can be complicated and should only be done by a m
19. arine electronics technician 4 2 3 Listening to incoming data To listen to incoming data from a specific comm port open the SMISealog Control Panel window Click the NMEA Processing tab and then the Comms tab and click on the required comm ports name from the list on the left entitled read input from Max 5 ports A tick will appear to the left of the comm port s name to indicate that SMISealog is listening to this comm port for data Up to five comm ports can be selected to receive data 4 2 4 Sending data Data can be sent from SMISealog out a comm port For example you can send data to a CNBX that is using the SmartNet system send data to another PC or device or send data to another comm port for another application To send data from a specific comm port open the SMISealog Control Panel window Click the NMEA Processing tab and then the Comms tab and click on the required comm ports name from the list on the right entitled Send output to Max 2 ports A tick will appear to the left ofthe comm port s name to indicate that SMISealog is sending data out this comm port Up to two comm ports can be selected to send data Piscatus Version 5 Installation Guide 25 4 2 5 Using the automatic NMEA setup feature The automati SMISealog an c NMEA setup feature is designed to lis d automatically set all NMEA string sett ten to the data being received by ings It does this by listening to the
20. d data to Piscatus3D This includes equipment like GPS echo sounder and data multiplexer Check data cables are correctly plugged into PC serial rs232 comm ports 2 Check for data in terminal Open the SMISealog Control Panel window by left clicking on the SMISealog icon and selecting the Control Panel option In the window that opens click the NMEA Processing tab and then the Terminal tab Select different comm ports from the Display Input list Data will appear as white lines of text against the black background each line will normally start with the character Note down a list of which comm ports display data Example data string SGPGGA 212812 4107 138 5 17423 858 E 1 7 2 1 1 M 19 M 22 Piscatus Version 5 Installation Guide In the SMISealog Control Panel window click on the NMEA Processing tab and then the Comms tab In the Read input from Max 5 ports list tick each of the comm ports for the appropriate input comm port as noted in Step 2 Finally tick the Enable Comms option to start data processing The quickest way to set up your NMEA processing options is to open the SMISealog Control Panel window click on the NMEA Processing tab and then the System tab and in here click the Auto Detect NMEA Settings button This process will monitor all incoming data for thirty seconds then automatically select the best options In the Net NMEA tab you
21. e simulation buttons and stopped by pressing the Stop SIM button As when playing simulation files the speed of the simulation can be changed by reducing or increasing the line delay 4 5 Fault Finding 4 5 1 Restoring factory defaults If SMISealog settings have been modified and SMISealog will not work correctly restoring factory settings may help This will restore comm port NMEA filtering and tide settings Once factory defaults have been restored all settings would have to be adjusted to the users setup again 1 To restore factory defaults open the SMISealog Control Panel window click on the NMEA Processing tab and then the System tab 2 In here click the Restore Factory Defaults button 4 5 2 Finding problems If Piscatus3D does not seem to be working correctly please check all of the following These checks are written at a marine technician level and do not give every detail on fixing the problem Check services n the bottom left of Piscatus3D there are six lights All six lights should be green for Piscatus3D to be working correctly If one or more light is not green place or mouse over he light and you will get a short message of the problem SeaDBLog can be restarted in Piscatus3D through the Help Support System Information window In the System nformation window that opens click the Database tab and in here you will see buttons called Stop SeaDBLog Service and
22. ecting into a boat s GPS sounder and seafloor discrimination device a database can be built of the seabed s depth hardness and roughness from the area the boat fishes Depths are then used to build a model of the seafloor and hardness and roughness characteristics are overlaid By getting accurate maps of the seafloor instantly a fisherman can increase the boat s efficiency markedly Seabed Mapping Piscatus3 Ltd is run by ex commercial fishermen and it is a policy that all our staff spend time at sea on commercial fishing boats Our experience and close association with the commercial fishing industry helps us to make our products as useful as possible and easy to use for fishermen We understand that fishermen want to catch fish and not learn about computers Piscatus3D can interact with the boat s plotter via a component called Shared Memory At the moment C Plot Pro and SeaPlot Pro are supported If a different plotter is used please contact Seabed Mapping and we can see if we can integrate with it as well This manual details the background components of Piscatus3D what they do and how they all work together the software installation procedure and the configurations necessary for the Piscatus3D system to work with the boat s electronic equipment This manual assumes a reasonable level of understanding of a PC windows and marine electronics Please consult the Piscatus3D user manual for learning how to operate the software
23. eplaced To continue press the Next button Reial Rar uti Tex ne 3 Onthe Install tab there are two options Select Install Piscatus3D Version 5 to install the full working version of Piscatus30 Or select Install Piscatus3D Version 5 Trial to install a 60 day version which also has full working functionality Note Trial installations can be converted to full installation after 60 days by purchasing a dongle and requesting a new full version permit code But please be aware that the system will not run once the 60 days has expired and that there may be some downtime before a dongle is received 16 Piscatus Version 5 Installation Guide 4 Once either the full or trial install option has been selected the installation will start This installation installs all required parts of the Piscatus3D system You will now be asked if you want to proceed with the installation on your local drive as shown below select Yes The default installation directory for Piscatus3D is C Piscatus3D A AQ O Setup 1 now red te tal Pacatus to your lacal dive De you wsh to vente ie j h 5 The first thing to be installed on your Open Fle Security Waring computer will be Firebird Database The palidver cesta pol bo varied fen gus aun pee want bs server 2 You may be displayed with RA g y p y A 1 Ima ktopinetaevertea rt meta pre a security warning before installation pu Brata innam Publio E Spa App
24. f the software The licence entitles the user a single licence to use one copy of the Software installed on a single terminal The sole entitlement of the user is as a licensee of the Software for the purposes of the user only Piscatus3D retains sole and exclusive copyright of the Software and written material supplied and neither the Software itself nor any written materials supplied with the Software may be copied by the user or made available to or used by any other person in any manner All other rights are solely reserved to Piscatus3D Limited Piscatus3 Limited s liability in respect of the Software is entirely limited to any performance failure relating to the Software itself when operated strictly in accordance with operator instructions Piscatus3D Limited s liability is solely limited to a refund of the purchase price of the Software In particular no liability is accepted for any failure caused by the operating environment in which the Software is installed or used any consequential loss or damage incurred by the user or any third party the consequences of any installation or reconfiguration of the user s operating environment by the distributor of the Software All warranties implied by the law of any jurisdiction are excluded to the maximum extent possible Piscatus3D Limited accepts no liability whatsoever for any failure breakdown or incompatibility of any related hardware supplied by its distributors or deale
25. ft Display incoming data click on the small white and red fish icon From this menu you Tide Graph can do simple tasks like starting and stopping tide adjustment v Start Tide Adjustment viewing the current tide graph or opening the SMISealog Stop Tide Adjustment Control Panel window A picture of the SMISealog menu is Help shown on the left Shutdown SMISealog Piscatus Version 5 Installation Guide 21 The top option called Control Panel opens the SMISealog Control Panel window where SMISealog settings are set and modified as shown below 3 PMA Proceserg tow Achmet abortado Syrien Comme feat NMEA Boat MAMA Niet hasta Ferg tet Fate Tarrant Pronat sats Goma Current States GGeeog Simulation running Lact Ore 63 09 Cate Statue FID F254 y Lat bae 007 131 S hast Date GP2D 070 21 20 14 DO kog Active Last Long 171051 E Last Toe 03 Tre bog Disabled Cors Enabled Los Disabled MAA Log Pine FT Record MEA to 2 F Sko recerting on date ros Mecrea Frwy rom aag loot Coen atat 1 2 Caan rpt The SMISealog control panel is designed using tab controls There are two main tabs along the top for NMEA processing and tide adjustment Beneath each of these main tabs are sub tabs that group different options available to the user The status bar along the bottom shows which comm ports are currently being used 4 1 2 SMISealog quick setup 1 Turn on all electrical equipment that has been wired to sen
26. gnore GPS position problems 30 4 2 11 Receiving ARPA target dt 30 NA e o e 30 4 3 1 How tide adjustments are calculated 4 3 2 Viewing current tide adjustment 30 4 3 3 Selecting a tide engine Check 31 4 3 4 Setting a default tide station to always be USC 31 4 3 5 Viewing a list of available tide stations in YOUF Al O 31 436 VIEWING THE TICES ARAN A on 32 Piscatus Version 5 Installation Guide 5 JA IMUATION S mainiota e Ae es oa acai Ae lence A Ah tas etic ca antl 32 AA TRECOIGING sinulat ones e 32 4 4 2 Playing recorded simulation files essessssssssoosssssusssesssssssssssssssssssssessssisssssssssussassesesssnsssssssssnsesseses 33 4 4 3 Simulation Options 4 4 4 Playing preset simulations 45 FAULT AND NG os ed e e e aE 45 LRESTOMNG LACTOIY CEIGUI ES 0 denen deme cae dot o abhi kaa deot bins dl cdo A are dl cb bd 35 BLAN problems ian A A ls 35 5 0 USING MULTIPLEXERS wssscsssscssocsssesestsnsssevenssscosssnsnssacsesbsvseseatonnsseosasastsescnstesvebstsbessenscscosseate 37 VEE A tee 37 DIM DAS e E nel tea bee ee E E EN 37 5 3 HOW TO CONVERT FURUNO CIF TO NMEA0183 WITH A DM 24 cacaos 39 6 Piscatus Version 5 Installation Guide 1 0 INTRODUCTION 1 1 What is Piscatus3D Piscatus3D is a computer program that makes maps of the seafloor or lake bed for commercial and recreational fishermen It has been designed to help fishermen catch more fish in less time By conn
27. ial fisheries to maintain a central database back at head office Piscatus Version 5 Installation Guide Piscatus3D also reads Shared Memory to dynamically update the terrain model and boat position in real time Only when a new position is rendered does Piscatus3D fetch points from the database Piscatus3D Inshore Pro and Piscatus3D DeepSea Pro both install from the same set of disks The Permit Code you are given by Seabed Mapping when licensing the software determines what mode Piscatus3D will run in and whether any additional modules are activated Navigator is another program that is opened from within Piscatus3D itself This program gives the user an overview of the world with coastlines boat tracklines and high resolution global bathymetry maps Piscatus3D Navigator is standard with all Piscatus3D nshore Pro and Piscatus3D DeepSea Pro installations and does not require any extra installation steps SmartNet is an add on module that can be purchased in addition to the standard Piscatus3D system It is a net positioning system that determines net location by matching depths received from the net sounder with seafloor depths stored in the Piscatus3D database SmartNet can be added on to any Piscatus3D DeepSea Pro installation f you are doing a SmartNet installation on a boat please contact Seabed Mapping for further details 1 4 Built in data Piscatus3D comes with a built in background dataset called Pred
28. icted Bathymetry that covers the planet This data is a one nautical mile grid cell dataset based on satellite altimetry The dataset is kept separate from the boat s actual soundings and once the boat has collected its own data the background data will be ignored where the owner s data is present Another type of background data is Piscatus3D relief data These are high detail data files available in some areas containing topographical and or bathymetry data for localized areas This data is typically used to draw land terrain for inshore and lake fishing The data is installed separately from the Piscatus3D background Predicted Bathymetry and is only available in areas where either topographical or bathymetry data is available in the public domain Typically the precision of this data is around 90m and therefore may produce some accuracy errors around the shorelines Note however that boat data collected will always override land data points present in same location 10 Piscatus Version 5 Installation Guide In some special cases supplementary data can be supplied as text XYZ data and imported into the user database via the Map Manager program This data may come from a number of different sources including other Piscatus3D users hydrographical offices and government agencies Instructions for importing this type of data can be found in the user guidebook 1 5 Computer specifications The minimum system requirements for running Piscatus
29. log to listen to your NMEA strings please try the Automatic NMEA setup feature For information on this please refer to section 3 2 5 4 2 7 NMEA examples Position heading and speed GPS SGPGGA GPS position and time SGPRMC GPS position and time SGPVTG Speed and course over ground SGPZDA Time and date Gyro SGPHDT Vessel heading Depth Sounder SSDDBT Depth below transducer SSDDBS Depth below sounder There is an option on the BOAT NMEA tab to enable support for an old JRC NMEA format with a leading U character Hardness Roughness data JRC JFC130 SPJRCS Hardness data SeaScan SPSAP Depth Hardness and Roughness data RoxAnn N A Depth Hardness and Roughness data Piscatus Version 5 Installation Guide 27 Furuno SPFEC Depth Hardness and Roughness data Net information When using any of the following please ensure that the correct net monitor is selected on the Piscatus30 Setup window Simrad ITI SIIGLL Net position SIIDBS Depth below sounder SIIHFB Trawl height footrope and bottom SIITDS Trawl spread Furuno CN22 SIIDBS Depth below sounder SIMTW Temperature Scanmar SSMDBS Depth below sounder SSMHFB Trawl height footrope and bottom SSMTDS Trawl spread Netview3D SIIN3D Net position depth range height and temperature Pacha Geonet SIISAL Net sensors range bearing and depth SIISAN Net sensors height temperature and spread 4 2 8 Primar
30. ns section at the bottom of the window click the Always use option then click the Set button 3 A message will pop up asking you to select the tide station to use dismiss this message by clicking the OK button You will automatically be taken to the Lookup tab of Piscatus3 Tide 4 Click the Set as default station button 5 You will be returned to the Current Tide tab and you will notice that the tide station you just selected is now displayed in the Always use box 4 3 5 Viewing a list of available tide stations in your area This feature is only available when using the Piscatus3D tide engine To view a list of available tide stations in your area open the SMISealog Control Panel window and click on the Tide Adjustment tab and then the Lookup tab Enter a latitude and longitude for your area and click the Lookup button The tide engine will search for tide stations around the Piscatus Version 5 Installation Guide 31 latitude longitude position entered up to the maximum range set the default is 40 000 metres The tide stations found to be within range of the latitude longitude entered will be displayed These tide stations can then be selected and set as a default tide station or their tide values can be viewed graphically 4 3 6 Viewing the tide station graph This feature is only available when using the Piscatus3D tide engine To view a tide graph open
31. oranien of Firebird Database Server as shown a FTAA ee ap eee below If displayed select Run Accept or Allow Ba I7 Aways ask betore opening Pws Me This le coes nat have s valc doai sqnetre fuat verfiss te ir You thosd sty an wins Som gt len you nat lisy can ceckse whut softeere Lo a 2 6 The HASP SRM Run Time Environment RTE is the next component to be installation a If you are installing the full working version the installation will ask you to insert you HASP dongle once the RTE is installed The window to the right Please insert your HASP dongle will be displayed This window will automatically disappear and the installation will continue once the dongle is detected If you do not have the dongle at this time select the Cancel Search button to continue anehna bor HAS Donda the installation Corcelfeacn b Ifyou are installing the 60 day trial version the installation will ask if you wish to have a 60 day license Select YES to this question Please note that this 60 day license cannot be un installed or re installed Piscatus Version 5 Installation Guide 17 7 Next the Piscatus3D application will be installed This is automatic and no settings and buttons must be touched The process windows as shown to the right will be displayed eae vat oris Soe neah Wea Don yas comme Swine tirs Ciao ep rejes Ma T pro 8 The underlying data sets that come with Piscatus3D
32. page shows one possible setup of a Piscatus3D system and the flow of data between the various Piscatus3D elements In this example data is given out from the various bits of electronic equipment on the boat in NMEA format Each of these data outputs are fed into a Data Multiplexer wh ich combines all the NMEA sentences into one data stream This data stream is then fed into the Piscatus3 gt computer via a single comm port This is a common setup for vessels with more than two devices outputting data to Piscatus3D Piscatus Version 5 Installation Guide Other possible Piscatus30 setup options are to receive the data via UDP using the computer s ethernet port or to send NMEA into multiple comm ports on the PC thus removing the need for a data multiplexer UDP data is only available from some NMEA Data Multiplexers or can be configured on another computer within the Piscatus32 computer s network This setup allows multiple data sources to be shared over an Ethernet network to multiple computers and multiple programs per computer Setting Piscatus3D SMISealog to listen to NMEA from many comm ports is a good option for users only requiring GPS and echo sounder data but correct precautions should be taken concerning electrical isolation and device earthing Please contact your Piscatus30 dealer concerning electrical isolation and device earthing with your installation PC oR Ret E elos 4 a ott roy AE tenes oe lt
33. r s Kientfy code email code lo seabed seabed co nz wih your details Copy code to cipbeard Copy code to dsk Emai entry code Enter your Parmi code here 2 Please supply Piscatus3D Limited with the 32 digit Computer Identity code either via email Ssupport piscatus co nz or through our website dealer login page http www piscatus co nz login htm If you do not have internet access you can phone us on 64 3 545 7020 or fax the code to 64 3 545 7021 We strongly recommend using either email or the internet and copying and pasting the codes so as to prevent any potential errors when copying them down Other Information we require is the Piscatus3D mode either Inshore Pro or DeepSea Pro vessel name and the company name the vessel belongs to The latter is only used when generating the Permit Code as Piscatus3D installations have encryption routines that take into account the parent company to allow data sharing between vessels using the Fleet Manager and Map Manager programs 3 Seabed Mapping will reply with a 64 digit Permit Code that should be entered in the bottom text field of the above Computer Identity window Once the Permit Code has been entered click the Accept button to continue Piscatus3D will automatically load after you have accepted the Licence Terms 4 Piscatus3 is now ready to use Click the Follow Boat option in the upper left hand corner of the screen and you will be taken to the curren
34. rs or otherwise used to operate the software This licence continues until terminated The user may terminate the licence by destroying the CD containing the Software and all written material supplied or returning it to the retailer distributor from whom it was purchased The licence terminates automatically if the user is in breach of any provisions of this licence Piscatus Version 5 Installation Guide 9 If any provision in this licence is held to be unenforceable by any Court having jurisdiction the rest of this licence will remain in full force and effect 10 This licence is governed exclusively by the laws of New Zealand and constitutes the entire agreement between the user and Piscatus3D Limited replacing the terms of any purchase order marketing material communication or any representation by Piscatus3D Limited or any distributor retailer appointed by Piscatus3 Limited ACCEPTANCE The intending user of the Software has read the terms of this licence and by ticking the box to install the Software accepts the above Licence Terms as exclusively constituting the terms of use of the Software 4 Piscatus Version 5 Installation Guide 1 0 INTRODUCTION ooconccococoonononononononononononononanononananonananarinanannononononononononononononononononononororranoririnanss 7 TIWHAT IS PICA TU nas 7 1 2 PISCATUSID MODE Sc 7 13 HOW PISCATUSO WORKS uine cia aNes eilacuaua ee a lain aaa otaiant 8 TWA BUNT IN
35. s3D Data MEAlogs folder Each simulation file is named based on its date created with extension txt For example a file created on August 31 2005 would be 31082005 txt Note for information on playing back a recorded simulation file please refer to the section 4 4 2 32 Piscatus Version 5 Installation Guide 4 4 2 Playing recorded simulation files In order to play a recorded simulation file NMEA settings must be correctly set This section of the manual only covers use of the simulation and not SMISealog setup Te To start a simulation open the SMISealog Control Panel window and click on the NMEA Processing tab and then the Simulation tab Click the button This will open an Open file dialog box use this to navigate to and select a NMEA simulation file Set the Play Options The play speed of the simulation can be adjusted by changing the Line delay m s We recommend 100 m s Increasing the line delay will slow the simulation Click the Start SIM button to start the simulation Check the simulation progress The simulation progress can be checked in two places The first is the progress bar below the Start SIM button this should be slowly filling as the simulation file is played Below the progress bar there is also a line count that should be increasing It is important to check the Terminal tab to make sure that simulation data is entering SMlSealog To do
36. should select the type of net monitoring equipment if any used ow check the incoming data In the SMISealog Control Panel window click the NMEA Processing tab and then the Comms tab and then click the Display incoming data button This will open the Incoming data window Check the different fields in his window there needs to be a minimum of the following items in order for Piscatus3 O operate UTC Date UTC Time Latitude Longitude Depth If some fields are missing like Heading or SOG go to the Boat NMEA tab and select the appropriate NMEA sentence type Heading may need to be changed from GPHDT to RMC Heading COG and SOG data is not essential but does make the software better to use Once you have selected a tide engine if a tide station is available in your area the above data will be enough to calculate its current height Allow up to 30 seconds for the tide engine to find a station after a lat long position is detected by SMISealog Additional tide station options can be chosen on the Tide Adjustment tab in the SMISealog Control Panel window If you have net sensors attached to your trawl this data should appear in the Incoming data window in the right hand column called Data From Net Most trawl sensor systems need to be in a simulation mode in order to output data when the net is not in the water Piscatus Version 5 Installation Guide 23 Note if
37. t boat GPS position Note SMISealog may need to be configured before Piscatus3D can receive GPS position and other data see section 4 0 20 Piscatus Version 5 Installation Guide 4 0 CONFIGURATION OF SMISEALOG After Piscatus3D has successfully installed you will need to configure it correctly so that it talks to the boat s electronic equipment Most of the required configurations are default settings but they may need a little tweaking depending on the boat involved 4 1 Introduction SMISealog is the data entry point for the Piscatus3D system SMISealog listens to the data being sent into the PCs serial comm port or UDP network This data is received in NMEA format from marine equipment for example GPS or echo sounder SMISealog then extracts the required data from this and shares it to Piscatus3D to be viewed SMISealog also uses GPS position date and time data to calculate the current tide at boat position This tide value is used by Piscatus3D to correct all recorded depth data to chart datum When you first install Piscatus3D there are some settings in SMISealog that will need to be set Please read the Quick setup section 3 1 2 of the manual for a brief description of this setup stage or read the remainder of the manual for a detailed step by step description 4 1 1 Using SMISealog SMlSealog runs as a background task to Piscatus3D and runs in EZEREN the Windows system tray To access the SMISealog menu le
38. ta Please refer to the Viewing incoming data section of this manual sends lines of data with taining an identifier and data delimited by commas There are many different some of which contain the same data Piscatus3D must be set up to process ta your equipment is sending Piscatus30 knows how to process many different eans setting the identifier g on the data type required An identifier is made up of er of SD and data type of DBS therefore the identifier d NMEA settings can be complicated and should only be EA setup is much easier Simply choose between JRC or scrimination systems There are red for this data We have found that different echo sounders f seafloor This offset value ta sharing between vessels n to your net positioning in areal position relative to the ect what type of net positioning ave Selecting one of these will set the correct N be adjusted for each installation EA setting below Settings 26 Piscatus Version 5 Installation Guide The default settings in Piscatus3D should be correct to get GPS position and echo sounder depth from most modern marine electronic equipment The best way to find what NMEA strings your equipment outputs in to use the terminal tab in SMISealog Use this to view a comm ports data and press the pause button to stop the data display update so you can read to the individual NMEA strings being received If you are having problems setting up SMISea
39. this click on the Terminal tab and click the Display SIM data button White lines of text should be appearing against the black background Check processed data Now check that all data is being processed correctly To do this select the Comms tab and click the Display Incoming data The Incoming Data window will now be displayed showing you which data is being received and processed Start Piscatus3D if all the above steps have worked correctly You will be able to watch the simulation play Piscatus Version 5 Installation Guide 33 4 4 3 Simulation options There are many specialized options which can be fine tuned in the simulator Below is a table of these options which a description on how to use them Option Description Line delay This option controls the speed of the simulation Simulation files are made up of NMEA lines of data increasing the delay between sending each line of data slows the simulation Default 100 m s File Repeat By default this is set to play once This means that the simulation will play from start to finish only once and then stop There are two further options for playing twice and forever Start or continue options These options allow the flow of the simulation file to be changed There are three options From start From line Continue From start starts the simulation from the start every time he Start SIM button is clicked
40. ving a problem therefore causing Piscatus3D to ignore all data There is a setup mode option at the bottom on the System tab in the SMISealog control panel Place a tick in this option to make SMISealog ignore GPS position problems so data can be checked in Piscatus3D This option is not saved and will be un ticked when SMISealog is next loaded 4 2 11 Receiving ARPA target data The settings for receiving ARPA target data are on the boat NMEA 2 tab in the SMISealog SMISealog is only able to receive data from the radar NMEA string RATTM If this string is being received that ARPA targets within that string will be listed on this tab There are no other settings which need to be adjusted 4 3 Using tide adjustment 4 3 1 How tide adjustments are calculated Piscatus3D is a utility built into SMISealog that uses data from tide stations around the world to calculate the tide Corrections can then be applied to depth data stored in the Piscatus3D database The tide station used to calculate the current tide is the closest station within range of the boat s position This range is 40 000m 40km by default but it can be changed Once the tide station is found the GPS date time or if unavailable your computer s date time is used to calculate the tide 4 3 2 Viewing current tide adjustment To view the current tide at the boat s position open the SMISealog Control Panel window click the Tide Adjustment tab and then the
41. will now be installed o APIO First to be installed is what we call the Predicted Bathymetry dataset This is the satellite altimetry dataset for the whole planet based on the ETOPO1 A E dear na Dira dataset and is what Piscatus3D uses for its initial maps Once a boat starts to add real data the bathymetry is immediately updated to use the real data 9 Once the Predicted Bathymetry installation has been completed an empty BATHYMETRY FDB database file is installed This database stores the boat s soundings and hardness roughness data 10 Following installation of the database Piscatus32 Navigator and high resolution bathymetry maps are installed 18 Piscatus Version 5 Installation Guide 11 When installation has completed a verification program is run to check everything has been installed correctly and all services are running Iintaaton crrptete Pecut sep segunes oyuer mhont to cormpless tha ina Retest Lam Rebost iise You will be notified when installation is complete In order to finish the installation process and start all required components and system reboot is required Options are displayed as shown below to reboot now or later It is recommended you reboot now 12 Before your Piscatus3D system will operate the installation will need to be permitted and SMlSealog will need to be configured to listen to the incoming NMEA data from the GPS echo sounder and
42. with the special demo dongle When you load the disk go to the Advanced Options tab and select the Display Demo Install button in the Install Setup menu When the dealer install option has been selected the button to install Piscatus3 should display the text Install Piscatus Demo Version The Dealer Demo version actually installs a database containing more detailed bathymetric data for display purposes Piscatus Version 5 Installation Guide 3 Trial installation A 60 day trial license for the full version of Piscatus3D can be loaded during the installation process When you load the disk simply select the Install Piscatus3D Version 5 Trial button on the default menu The trial version does not require a dongle although a permit code is required for the system to function Please note that once installed these 60 day trial licenses cannot be un installed or re installed The license will remain on the system for 60 days After 60 days the installation can continue to be used if a dongle is inserted into the computer although you will need to contact us in sufficient time for us to physically get a dongle to you The trial version has full Piscatus3D version 5 functionality i e it can receive and save GPS sounder etc data Piscatus Version 5 Installation Guide 13 Piscatus3D Functional differences Demo vs Full License FEATURE Receives instrument inputs DEMO LICENSE FULL LIC
43. y and Secondary depth data and auto switch Some vessels have more than one echo sounder One could be a backup or preferred at increased depths The Sounder Data section of the Boat NMEA tab allows SMISealog to be setup to receive data from two different NMEA strings SMlSealog will switch from primary to secondary or vice versa automatically when no depth data has been received for some time or when the auto switch depth is crossed 28 Piscatus Version 5 Installation Guide 4 2 9 Filtering data To access the filter settings open the SMISealog Control Panel window click the NMEA Processing tab and then the Filtering tab The Piscatus system does data cleaning and these are the filtering settings here in SMISealog These settings allow incoming data points to be compared with recent data points and are designed to filter out erroneous data points for example double echo used as bottom depth by your echo sounder Filter setting Description Vessel position Sometimes GPS position can jump and cause Piscatus3D to load another 3D seabed map By setting this option GPS positions further than 1000 metres from your last known good position will be ignored This is automatically corrected if more than six GPS positions are found to be beyond 1000 metres Min max acceptable depth This is a simple check on the data coming in from the echo sounder It basically stops huge errors from the

Download Pdf Manuals

image

Related Search

Related Contents

DMS Go - GE Measurement & Control    Bomba de calor de aire/agua dividida  HM*-16  こちら - 株式会社エスキュービズム通商  Damian full shop  R0E001000EXT00 Users Manual (External Trigger Cable for E100  TempSpray-H306 TempSpray-H206 TempSpray-H106  NS フリーアドレスタイプ取扱説明書 - Garage  

Copyright © All rights reserved.
Failed to retrieve file