Contents

1. www moxa com support Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 Table of Contents 1 CICK AGO PIUS ROV 0 tuaied CCK SCOPUS ESA restan E E E EOS SEARS ClEkSGO PISM ULLOA A A A A A A Zi ClIEKSGO Plus Components crsa scuateccdendscceesnetusbenercusaucas Ii SNM staan ctunicd 0004 0000000000 AAA AE AAA ASA AA AAA DA TFE VS SS Nee PA S eat oaanss ea teG uae o o o o Rae S eek a Seneca il Et Arar CaP re EPO CGE te Mn 0 CINE EENIA Remote ACION eenn rere nour corti O oe CERC 7 Se 6 0 Pl S RU ES 22 1 NERAN EANNAN ANENA aR SA Lene Ea SR nen re ee eee ee re Te eee 3 5 TES INSEE 0 A ue aoe nai a A TYDES OIE CONdIOAS sos TYDES Or TREN BESE 60 iS ESEO KIF CONCILIO NS erretiro eiis eris Ee EErEE EEEE EEEE EENEN EENEN ENEE EEEE ANAN AAAA EEE EistOf THEN ELSESACUONS versie R 4 Click amp Go Plus 1 l Starting a 5 07 A ii 1 Overview Moxa s ioLogik 2500 is a remote I O device designed for smart monitoring applications over Ethernet With
2. only be triggered when Client IP and Action ID match 2 6 Click8 Go Plus Click8 Go Plus Components CGI Commands CGI commands can be used with Click amp Go Plus Using a web browser or standard HTTP protocol makes it easier for a security SCADA system to monitor and control an ioLogik 2500 via CGI commands Using the as server option allows the ioLogik 2500 to play the role of server to receive CGI commands and use CGI commands in Click amp Go Plus conditions Using the As Client option allows the ioLogik 2500 to play role of client to send CGI commands and use CGI commands in Click amp Go Plus actions NOTE CGI commands are case sensitive The default strings for sending CGI commands to the ioLogik 2500 are GET Method http IP address Port cg CGIMOXA Command 9 GET Method http domain port path query path query string length 17 max 99 http ff 192 168 1 254 8 1 7 CGIMOXA Command Post Method http I1P address Port cg CGIMOXA Command POST Method path post content length 17 max 99 http 192 168 1 254 80 f Content application x www form urlencoded only CGIMOXA Command 2 7 3 Click8 Go Plus Rules Click amp Go Plus logic was developed by Moxa to provide an easy way to program your ioLogik 2500 In this chapter we explain how to use Click amp Go Plus logic to deploy a remote I O solution The following topics are covered in this chapt
3. Click amp Go Plus User s Manual First Edition August 2014 www moxa com product MOXA 2014 Moxa Inc All rights reserved Click amp Go Plus User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice O 2014 Moxa Inc All rights reserved Trademarks The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact Information
4. Click amp Go Plus intelligence built in the ioLogik 2500 can be configured for simple outputs paired up with simple input triggers without using a PC controller Click amp Go Plus intelligence allows the ioLogik 2500 to be configured to automatically report I O events according to user specified conditions Simple IF Then Else statements are used to specify conditions that are required for certain actions to take place Up to 8 conditions and 8 actions can be combined in one rule and up to 48 rules can be defined Supported actions include sending SNMP traps or TCP UDP messages to up to 10 hosts at a time The following topics are covered in this chapter O Click amp Go Plus Overview O Click amp Go plus Features O Using Click amp Go Plus Logic Click8 Go Plus Overview Click amp Go Plus Overview Click amp Go Plus logic can be managed and configured with the IOxpress utility to handle front end events IOxpress s graphical user interface also provides easy access to all status information and ioLogik 2500 settings Click amp Go plus Features Click amp Go Plus Logic has the following key features e Easy local logic control using graphical and intuitive IF Then Else style constructions e Up to 48 user defined rules e Choice of email TCP UDP and SNMP trap for active I O messaging e Customizable message content with dynamic fields for time date IP address and more e Up to 10 simultaneous IP destinations f
5. ay Monday Tuesday Wednesday Thursday Friday Pl Saturday Range of Recurrence Startson 2014 12 5 gr 8 No end date Ends after 10 occurrences O 0685 214 139 B 25 Click8 Go Plus Click8 Go Plus Components Internal Register The Internal Register Integer represents a status flag to link the status of the first logic to the second one by specifying other actions in the THEN ELSE fields Internal Register Setting Unsigned Short Float Internal Register Setting Float E J Hame Internal Register 00 Internal Register 01 Internal Register 02 Internal Register 03 Internal Register 04 Internal Register 05 Internal Register 06 Internal Register 07 Internal Register 08 Internal Register 09 Float Internal Register 00 Float Internal Register 01 Float Internal Register 02 Float Internal Register 03 Float Internal Register 04 Float Internal Register 05 Float Internal Register 06 Float Internal Register 07 Float Internal Register 08 Float Internal Register 09 oOo 2 D O O D Ol amp amp Remote Action The Remote Action function can be used to connect between several ioLogik 2500 devices e The As Server function can be used in IF conditions to trigger the local device e The As Client function can be used in THEN ELSE actions to trigger a remote device Mame Remote Acton_Server_0 Setting Client IP 0 0 oO 0 Action ID 01 NOTE For As Server the device will
6. ed using different protocols value or state Sends message or data Includes both Digital and Analog 5 package using different IO types protocols List of IF Conditions Parameter Type Parameter acions DI DI Ch ON OFF Change Change from OFF to ON IS DO Ch ON OFF Change Change from OFF to ON Relay Ch ON OFF Change Change from OFF to ON odios Host Connection Fall TRE Remote Action Remote Action Server TRUE sMS TRUE TRUE Second Parameter Other Parameter IO gt 1 V 1 V 1 V 1 V V 1 V V 1 V V 1 V l I TY A A 1 1 1 l I ry l T l T SMS CGI Command CGI Serial TAG Boolean Serial TAG TRUE Parameter Type Parameter Virtual channe VER Virtual Channel Serial TAG Serial TAG gt lt Float DWORD WORD 3 3 Click8 Go Plus Click amp Go Plus Rules List of THEN ELSE Actions Parameter Type Parameter Actions SSS poi CONOR outer A er Parameter Type Parameter Actions S SNMP Trap Trap Send Every Sec 0 Send One Time Repeat only 00 930 4 when IF condition still exist for certain period of time TCP UDP Message Message Send Every Sec 0 Send One Time Repeat only en pee when IF condition still exist for certain period of time E Mail e mail Send Every Sec 0 Send One T
7. er O Click amp Go Plus Rules O If THEN ELSE Conditions Structural Categories Types of IF Conditions Types of THEN ELSE Actions List of IF Conditions List of THEN ELSE Actions Vv VW V WV Click8 Go Plus Click8 Go Plus Rules Click amp Go Plus Rules After you finish configure Click amp Go components you can create Click amp Go Plus rules Click amp Go Plus logic provides an easy way to program your ioLogik 2500 product for Smart Ethernet Remote I O operations The main Click amp Go rules page is shown below ef Moxa lOxpress CMOxpre Project Device Configuration Online Device Options Help E Offline Configuration 2 Slot 00 Model 2542 T Server Ol If THEN ELSE Conditions Structural Categories IF Condition THEN Action ELSE Action Types of IF Conditions eSupports physical IO and software components software IO EVENT eMonitors the result of Boolean type output e g True False Enable Disable Start Stop eUsually used with Digital IO types eSupports physical IO and software components software IO COM PARISON eMonitors the result of numerical output types eUsually used with Analog IO types 3 2 Click8 Go Plus Click amp Go Plus Rules Types of THEN ELSE Actions Actions Active Message Supports physical IO and software components software IO Specific types of Actions that contain customized content Sets the result of output to fix
8. etting Name Timer_0 Time Interval 53 SEC Initial State 2 2 Click8 Go Plus Click8 Go Plus Components SNMP Trap The ioLogik supports SNMP Simple Network Management Protocol v1 v2c to allow monitoring of the network and 1 0 devices with SNMP Network Management software SNMP Trap can be used for THEN ELSE actions It is useful for building automation and telecom applications The SNMP Trap function sends an SNMP trap to one or more IP destinations The trap number can be any number between 1 and 20 You may need to consult with your network administrator to determine how trap numbers will be used and defined on your network Mame SNMP_Trap_0 server Settings Version vi v Server 11P Address 0 0 0 0 Server 2 IP Address 0 0 0 0 Server 1 Trap Community public Server 2 Trap Community public Parameter Settings Slot Select Specific ID Slot 00 Model 2542 T Slot 00 Model 2542 T Slot 00 Model 2542 T Content Settings Send as ASCII Content 0 max chars 200 Keyword Lookup 2 3 Click8 Go Plus Click8 Go Plus Components TCP UDP Message The TCP UDP Message feature enables you to configure one or more IP addresses of the Message Servers to which Click amp Go Plus logic sends the generated event messages Click amp Go Plus logic sends the defined active message to all addresses listed Configure the following fields in the Server Settings area e Server 1 2 IP Address Ente
9. ime Repeat only ee 2 when IF condition still exist for certain period of time SMS SMS Send Every Sec 0 Send One Time Repeat only gt 03 when IF condition still exist for certain period of time CGI Command CGI Send Every Sec 0 Send One Time Repeat only badass AE when IF condition still exist for certain period of time 3 4 4 Click amp Go Plus Simulation Click amp Go Plus Simulation is a tool provided for users to simulate the Click amp Go plus rules discussed in Chapter 3 The following topics are covered in this chapter O Starting a Simulation Click8 Go Plus Click amp Go Plus Simulation Starting a Simulation The following figure shows the main settings page of Click amp Go rules 7 Oxpress Project Device Configuration Online Device Options Help E Offline Configuration 2 Slot 00 Model 2542 T Server 0 Condition 0 Click the conditions tab to change the status of a condition All of the relevant information will be shown in the Log Messages column Condition 0 O A Event Rule_0 Condition 0 Set Slot 00 Model 2542 T DIO 00 DI ON Click Run Once to start a simulation The simulation result will be shown as T True or F False ee T Condition 0 Tr 4 2
10. or TCP UDP messaging e Internal register function for remote output control when Click amp Go plus is running e Timer Delay function for timing events e Configurable interval for time triggered events Using Click amp Go Plus Logic The following flowchart shows an overview of the Click amp Go Plus Logic configuration process 1 Set up 2 Create 3 Design 4 Run I O Components C amp G Components C amp G Logic Rules C amp G Simulation More information is available about each of these four topics e Setting up 1 0 Components See the ioLogik 2500 User s Manual e Creating C amp G Components See Chapter 2 of this manual e Designing C amp G Logic Rules See Chapter 3 of this manual e Running C amp G Simulation See Chapter 4 of this manual 1 2 2 Click8 Go Plus Components Click8iGo Plus components can be used to specify conditions and actions that are required for certain actions to take place Up to 8 conditions and 8 actions can be combined in one rule and you can define up to 48 rules The following topics are covered in this chapter Timer SNMP Trap TCP UDP Message Email Schedule Internal Register Remote Action CGI Commands O O O O O O O O Click8 Go Plus Click8 Go Plus Components Timer The Timer function can be used to control the timing of logic rules in the IF conditions Use Time Interval to repeat the same action periodically Interval sec Timer S
11. r the IP address of a message server e Message Protocol Select the message protocol TCP or UDP to use from the drop down list e Message Port Set the port number the computer uses to communicate with the device The default TCP UDP port number is 9000 e Retry Enter the number of connection attempts e Interval Enter the number of seconds the device will wait before sending an active message Name TCP_UDP Message 0 server Settings Server 11P Address 0 0 0 0 Server 2 IP Address 0 0 0 0 Message Protocol i Message Port TCP UDP 3000 Retry 3 Interval sec 0 Content Settings Send as ASCII 5 Send as UNICODE 5 Send as HEX separated by Keyword Lookup Content 0 max chars 200 Email The E mail function can send a customizable email to one or more mail boxes Click8 Go Plus Components Click8 Go Plus Schedule The Schedule function can be used in an IF condition It allows users to set a starting point or time period for a task For recurring actions you can select the relevant weekdays If a time period needs to be defined specify the settings in the Range of Recurrence column For example the Schedule function can be used if a pump needs to start at 9 00 PM and stop at 11 00 PM every Monday Wednesday and Friday Schedule Name Periodic_0 Mode Periodic ll Time Starts 19 56 26 Ends 19 56 26 Recurrence Pattern Weekly Recurevery 1 week s on Pl Sund