1. 2 80 Pause Play If the signal is active the screen can be paused by touching HI Pause is located in the menu bar on the far right side If the signal is paused the screen will resume real time measurements by touching gt i In order to capture a single shot wave form touch and hold HI or peda until it changes to a Then touch waveform Single shot waveform catpure is a feature more for the dynamic power meter but if the setting is changed on and it will capture a single shot the power meter it will remain in that state on the spectrum analyzer To change it back to pause play press and hold 2 90 Host Properties From Demo Mode touch from the bottom right corner of the menu screen to view host properties When hardware is plugged in and product is in active mode touch from the bottom right corner of the menu screen to view host properties Here is an example of host properties on an iPad Host Properties Version 0 9 0 Device iPad Connection Type Supported UART USB OK iOS version 3 1 3 or newer is required for WiPry to operate Section 3 Switching Spectrum Mode to Power Mode While in spectrum mode touch ala It will then change to df These menu item allow you to switch or toggle from spectrum mode to power mode and back again 13 Revised November 17 2011 AN WiPry Combo Manual Section 4 Spectrum Analyzer Performance 4 10 Detailed Performance Specifications O scium designs RF t
2. LSCIUM WiPry Combo Manual Innovation for Inventors Table of Contents Spectrum Analzyer Section 1 Getting Started with SAFETY 1 10 Quickstart Guide 1 20 Getting Started with SAFETY 1 30 Compatibility 1 31 Hardware 1 32 Software Section 2 How Spectrum Analyzer Works 2 10 Menus 2 20 Spectrum Views 2 21 Real Time View Waterfall View 2 22 Raw 2 23 Hold Decay 2 24 Average 2 25 Int Atten Ext Atten 2 26 Clear Waveforms 2 30 Cursors 2 31 On Off 2 32 Axis 2 33 Mode 2 34 Horizontal Cursors 2 35 Vertical Cursors 2 40 Measurements 2 50 Colors 2 51 Real Wave 2 53 Decay 2 54 Average 2 55 Max Hold 2 56 Min Hold 2 60 Demo 2 70 Settings 2 71 Grid Settings 2 72 Alerts 2 73 Sounds 2 74 Units 2 75 Screenshot 2 76 Email 2 77 Manage Data Log 2 78 Configuration Settings 2 80 Pause Play 2 90 Host Properties Section 3 Switching Spectrum Mode to Power Mode Section 4 Spectrum Analyzer Performance 4 10 Detailed Specifications Dynamic Power Meter Section 5 How WiPry Power Works 5 10 Menus 5 20 Power Meter 5 21 Int Atten 5 22 Fxt Atten 5 23 Reference wave 5 30 Cursors 5 31 On Off 5 32 Axis 5 33 Mode 5 34 Horizontal Cursors 5 35 Vertical Cursors 5 40 Measurements 5 50 Trigger 5 51 RF Triggering 5 52 Digital Iriggering 5 53 Auto vs Normal 5 54 Dela 5 55 Holdoff 5 56 Single shot Waveform Capture 5 60 Demo 5 70 Settings 5 71 Grid Sett
3. 2011 WiPry Combo Manual iPad iPhone iPod The option that is touched will activate From the menu select the desired triggering function from these options single channel only GB simultancous events on two channels WB a single event on one of two channels GE or concurrent events on two channels WB 2 Below the selected triggering functions touch either E or 6 to select digital channel one D1 or digitial channel two D2 which will be used as channels A and B respectively 3 After locating the desired digital channel touch QB and when activated it will change to A D2 In this example channel A is now D2 4 To choose whether triggering occurs on a rising or falling edge either select for a falling edge or select cea fora rising edge 5 53 Auto vs Normal Touch BI Then touch common Touch the desired mode either AUTO or NORMAL For example if activating AUTO mode touch QB and it will change to GTI Repeat the process for NORMAL mode The default setting is AUTO 5 54 Delay To set the trigger delay from the main screen touch the screen and swipe horizontaly to move the trigger point The bottom portion w will detach from the top to set the trigger position To set the trigger delay from the trigger menu touch then select R and press MITO located next to DELAY A pick wheel will appear that allows you to set the delay time to the value shown in the readout To select the desired trigger delay
4. cursor in the vertical direction and place where desired The selected cursor will be displayed as a solid line and the un selected cursor a dashed line The position of the selected cursor is indicated next to mW or dBm in the summary bar The distance between the two cursors is indicated next to AmW or AdBm in the summary bar If cursor data is to be displayed in Base touch MIS The unit of measure is listed across from the word Unit The default setting is QE but it can be changed to mW If cursor data is to be displayed as a ratio touch ae The options next to the phrase 100 WITHIN set the ratio Ratio settings available next to 100 WITHIN include EI The option of EDM sets 100 within grid or the display screen The STESSI option sets 100 between the two cursors 5 35 Vertical Cursors Touch the ES icon from the menu bar Touch I to activate cursors Touch from the cursors menu On the main screen touch and swipe the desired cursor in the horizontal direction and place where desired The selected cursor will be displayed as a solid line and the un selected cursor a dashed line The position of the selected cursor is indicated next to t in the summary bar The distance between the two cursors is indicated next to At in the summary bar The point where the selected cursor crosses the waveform is indicated in the summary bar next to mW or dBm and the vertical difference between the crossing points of the two vertical cursors is in
5. on and off respectively On the main screen touch and swipe the desired cursor in the vertical direction and place where desired The selected cursor will be displayed as a solid line and the un selected cursor a dotted line The position of the selected cursor is indicated next to dBm or mW in the summary bar The distance between the two cursors is indicated next to AdBm or mW in the summary bar If cursor data is to be displayed in Base touch MITI The image next to the word UNIT QQ allows you to view the current unit of time If cursor data is to be displayed as a ratio touch EI The options next to the phrase 100 WITHIN set the ratio Ratio settings available next to 100 WITHIN include Ca The option of GRID sets 100 within the screen divisions or grid divisions The CURSOR option sets 100 between the two cursors 2 35 Vertical Cursors Touch the icon from the menu bar Touch J to activate cursors Touch from the cursors menu On the main screen touch and swipe the desired cursor in the horizontal direction and place where desired The selected cursor will be displayed as a solid line and the un selected cursor a dashed line The position of the selected cursor is indicated next to Hz in the summary bar The distance between the two cursors is indicated next to AmW or AdBm in the summary bar The point where the selected cursor crosses the spectrum waveform is indicated in the summary bar next to dBm The vertical differe
6. the desired measurements To activate the settings touch away from the menu or touch 2 22 Raw Touch Gi on the menu bar then touch II and scroll through the pick wheel until it RAW is highlighted To activate the raw view touch away from the menu or touch Back 2 23 Hold Decay Touch cy on the menu bar In the default setting should be selected Once decay is activated both the advanced options for hold and decay will be activated To change the advanced option touch and swipe the dot to the right of either hold or decay Decay amp _ gt 00m While decay is activated it is also possible to simultaneously select any two other real time views 2 24 Average Touch cy on the menu bar In the default setting ENS should be selected When selected an advanced sliding bar is then activated below To change the advanced options touch and swipe the dot to the right of average AVERAGE Que 2005 K 2 24 Int Atten Ext Atten Touch Gi on the menu bar To change the Internal Attenuation Int Atten level touch E 10 the right of Meee Enter the desired value using the pick wheel To activate the setting touch away from the menu or touch To change the External Attenvation level the same procedure should be followed Touch EI to the right of CAEN Enter the desired value using the pick wheel To activate the setting touch away from the menu or touch 2 25 Clear Waveforms To clear waveforms touch Gi on the menu b
7. touch and drag in each of the four columns until the specific value is reached To activate the settings touch away from the menu or touch BACK 5 55 Holdoff Touch in the menu bar to enter the trigger menu Touch COMMON J Touch MITO next to HOLDOFF to set the holdoff time Setting the HOLDOFF value should be done in the same manner as the delay 5 56 Single Shot Waveform Capture If the signal is active the screen can be paused by touching m Pause is located in the menu bar on the far right side If the signal is paused the screen will resume real time measurements by touching Leal In order to capture a single shot wave form touch and hold HI or until it changes to a Then touch and it will capture a single shot waveform Once this menu item is changed to single shot waveform capture it will remain the menu option even when switching to the spectrum analyzer To change it back to pause play press and hold id 20 Revised November 17 2011 iPad iPhone iPod 5 60 Demo Touch a Four different settings exist None WiFi DECT and DSSS Once a setting is selected it will change from wma to OwA O On the iPhone and iPod touch press and hold a and it will change to Ea That way the options available in the settings menu are viewable while still in demo mode Once hardware has been plugged in however demo mode no longer is available 5 70 Settings appears in the main menu bar of the iPad at all times On the iPho
8. touch and swipe the dot to the right of the text To change Peaks on top touch OLE ap Six options exist None Raw Decay Average Max Hold and Min Hold Select the desired option by scrolling through the pick wheel to activate the settings touch away from the menu or touch Back ff PEAKS ON TOP es ee PEAKS DECAY PEAKS AVG PEAKS NONE 2 50 Colors 2 51 Real Wave Touch heee Then touch Either 09 or S in the menu Then select the desired color using the color palette To activate the settings touch away from the menu or touch BACK To clear the setting touch CANCEL To select the desired color threshold touch MERI next to either Min or Max Then select the desired units using the pick wheel To activate the settings touch away from the menu or touch BAcK 8 Revised November 17 2011 iPad iPhone iPod The threshold level is controlled with w located on the far right of the screen Touch and drag the bubble either up or down in order to manually change the threshold A horizontal line and 600dBm will then appear to the right of w i Also the interface will show a color gradient using the selected colors for Min and Max To set the colors to a default Rainbow setting touch QM When Rainbow is selected it will look like and both Min and Max will be grayed out To personalize Raw Wave colors touch either CD or e and select a color from the pick wheel RAW WAVE RAIN
9. BOW To reset colors to default touch SSIS 2 52 Heat Map Touch Zi Then touch either SD or SE in the menu Then select the desired color using the color palette To activate the settings touch away from the menu or touch Es To clear the setting touch CANCEL To select the desired color threshold touch QB next to either Min Mid or Max Then select the desired units using the pick wheel To activate the settings touch away from the menu or touch Back ff Revised November 17 2011 9 WiPry Combo Manual iPad iPhone iPod To set the colors to a default Rainbow setting touch GMB When Rainbow is selected it will look like and Min Mid and Max will be grayed out To personalize Raw Wave colors touch either AMM GRID or O and select a color from the pick wheel RAW WAVE RAINBOW To reset colors to default touch SS 2 53 Decay Touch al then touch a next to the phrase Then select the desired color using the color palette To activate the settings touch away from the menu or touch BACK To clear the setting touch CANCEL 2 54 Average Touch Ree Then touch faa next to the phrase Seatla tate E Then select the desired setting in the pick wheel To activate the settings touch away from the menu or touch BACK To clear the setting touch CANCEL 2 55 Max Hold Touch per Then touch Gees next to the phrase aw alele ze Then select the desired setting in the pick wheel To ac
10. To scroll through the measurement options touch ne Then scroll thorugh the pick wheel to choose the desired measurements To activate a selection make sure it is highlighted and then touch away from the menu or touch Up to six measurements can be selected simultaneously Measurements appear on the top right of the interface 5 50 Trigger 5 51 RF Triggering The trigger level is controlled with w located on the far right of the screen Touch and drag the bubble either up or down Moving the level up will increase the trigger level and moving it down will decrease the trigger level The exact trigger level will appear just to the left of the bubble along with either an up arrow or a down arrow An up arrow indicates that the trigger is on a rising edge a down arrow indicates that the trigger is on a falling edge It is also possible to change the trigger level in the advanced triggering menu Touch BI Then touch SAE and when active it will change to EIA To navigate to an exact trigger level touch on EER next to the word LEVEL The power trigger level pick wheel will then appear in either dBm s or mW s To select the desired trigger level touch and drag in each of the four columns until the specific value is reached To activate the settings touch away from the menu or touch BACK 18 Revised November 17 2011 AN iPad iPhone iPod When RF power triggering has been enabled then all the advance
11. ar Then touch CLEARWAVEFORWS 2 30 Cursors 2 31 Cursors On Off Touch on the menu bar Touch J to activate cursors With real time wave views it is possible to select either 6 Revised November 17 2011 iPad iPhone iPod horizontal or vertical cursors With the waterfall view both the horizontal and the vertical cursors will be activated 2 32 Cursor Axis Touch either the HORIZONTAL cursor or the cursor Double tap the interface until the summary screen appears Metrics relating to the cursors appear in the center of the summary screen 2 33 Cursor Mode There are two modes available on this device and TRACKING Upon activating cursors two lines will appear One is dotted and the other is solid The solid line is active and can be moved while the dotted line is stationary unless the cursors are in tracking mode While in tracking mode both the solid and dotted lines will move together In independent mode the solid line is the only line that can be moved Additionally dynamic metrics related to the solid line are available in the summary screen located at the bottom Touch on the dotted line and it will become a movable ui line while the other line will change to dotted 2 34 Horizontal Cursors Touch the REG icon from the menu bar Touch QQ to activate cursors Touch HORIZONTAL from the cursors menu and it will change from HORIZONTAL to Size iS Touch KIB and E 10 turn the horizontal cursors
12. d respectively and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Please note that the use of this accessory with iPod iPhone or iPad may affect wireless performance 3 Revised November 17 2011 WiPry Combo Manual 1 20 WiPry Spectrum SAFETY Do not apply more than 20dBm to the antenna without attenuation Oscium is not held liable for usage outside of these limits 1 30 Compatibility 1 31 Hardware WiPry works on these specific Apple devices iPod touch 1 22 3 and 4 generation iPhone 4S iPhone 4 iPhone 3GS Made for iPhone 3G iPhone iPad 2 iPad iPod DiPhone _ iPad 1 32 Software WiPry is compatible with all generations of the iPod touch iPhone and iPad devices running iOS version 3 1 3 or higher Three distinct products are available under the WiPry brand WiPry Spectrum WiPry Power and WiPry Combo Once hardware is connected the system will automatically recognize whether it is the spectrum analyzer WiPry Spectrum or the power meter WiPry Power or both WiPry Combo The connected hardware will enable the appropriate functionality If hardware has not been detected demo mode will simulate data Test drive the software for free by downloading WiPry from the Apple App Store Available on the a App Store 4 Revised November 17 2011 LS Section 2 Ho
13. d options for digital triggering will be grayed out To reactivate the RF power trigger touch any of the options on the picture below and it will no longer be grayed out The same process applies for reactivating the digital triggering RF power triggering is only available with hardware it is not avaiable in demo mode To trigger off of a rising edge touch B If rising is already activated it will look like IGIENE This means that falling is deactivated because both falling and rising cannot be active at the same time If rising is deactivated it will look like BEE Touch it once and it will activate to GSN To trigger off a falling edge the same procedure should be followed Falling should look like VERN when activated and FALLING when deactivated To recenter your trigger level touch GEREN and your signal will be brought in line with your signal 5 52 Digital Triggering This feature is also only available with hardware it is not available in demo mode When in demo mode all the digital triggering options are grayed out 1 Touch es from the menu bar Then touch BSUS at the top of the menu to view more advanced digital triggering options All the options may be grayed out because power and digital triggering cant both be active at the same time If power is grayed out digital is active and vice versa To activate the desired trigger touch one of the advanced triggering options 19 Revised November 17
14. dicated in the summary bar next to AmW or AdBm When using vertical cursor t At and mW AmW or dBm AdBm will be visible in the summary bar Verify that cursors are selected To move cursors independently of one another touch MERA To move cursors as a single unit with a fixed distance between them touch TRAcKING The following options are available 1 If cursor data is to be displayed in Base touch MESJ The options next to the word UNIT set the unit of time Time settings available in the Base option include QB The NI option sets the unit of measure in seconds The He option sets the unit of measure in hertz 2 If cursor metrics are to be displayed in Phase touch PHASE The options next to the phrase 360 WITHIN sets the phase The option of gag sets 360 within 5 divisions The WEJ option sets 360 between the two cursors 3 If cursor data is to be displayed as a ratio touch ERNOD The options next to the phrase 100 WITHIN set the ratio Ratio settings available next to 100 WITHIN include CIN The option of gg sets 100 within 5 divisions The RED option sets 100 between the two cursors 17 Revised November 17 2011 WiPry Combo Manual iPad iPhone iPod 5 40 Measurements Touch pini from the menu bar Fifteen different measurements exist Min Max Mean Peak to Peak RMS Duty Cycle Duty Cycle Pulse Width Pulse Width Cycle Mean Cycle RMS Frequency Period Rise Time and Fall Time
15. e appropriate word or icon The following options exist in the menu bar GENE ps Pe pet When hardware is plugged into the iPad the demo option disappears On the iPhone iPod touch the same optio exist in demo mode fo that the settings option is not viewable To view settings in demo mode press and hold Po and it will change to Touch al on the menu bar This will allow you to toggle to spectrum analyzer mode To toggle back to power meter mode touch EN 15 Revised November 17 2011 A WiPry Combo Manual iPad iPhone iPod 5 20 Power Meter 6 21 Internal Attenuation Touch on the menu bar Touch SEB to the right of the word AAE Then select the desired setting in the pick wheel To activate the settings touch away from the menu or touch Back 5 22 Fxternal Attenuation The same process should be used when changing the external attenuation Touch on the menu bar Touch EE 10 the right of the word EXT ATTEN Then select the desired setting in the pick wheel To activate the settings touch away from the menu or touch BACK 5 23 Reference Wave Touch on the menu bar Then touch grab GO to create a reference wave for the power output When a wave has been captured GB will change to GED and GAB will change to UO Once the wave has been captured it is saved and available for future use by touching reference The reference wave will appear as a white wave and Q will appear to the far left of t
16. e pictures are still available in photos where they can be emailed The other option is to simultaneously press both the home button and the power button on your Apple device The screen will flash white while the picture is captured When a picture is captured this way everything visible on the LCD will be captured and available in photos where they can be emailed 5 78 Manage Data Log This feature is only available with hardware it is not available in demo mode When in demo mode the data logging options for DATA LOG START and STOP are grayed out Touch E from the menu bar Then touch START from the data log option EG J START will then change to RD in order to indicate data is being logged To stop data logging touch BB Touch kJ Then touch GB A pick wheel will appear with all of the data that has been previously logged where it will be possible to email the raw data that has been collected 5 79a Configuration Settings Reset Configurations To reset the configuration touch Bi Then touch RESETCONFIG Saving Configurations Up to three configurations can be saved at a time Touch EH Then touch next to CONFIG 1 2 or 3 will then change to MIEI in order to indicate that the configuration is saved To upload a saved configuration touch m aa will then briefly change to indicating that the configuration has been loaded 5 79b Pause Play If the signal is active the screen can be paused by touching HI Pause i
17. est equipment you want to get your hands on We leverage the intuitive features and touchscreen technology found in the iOS family of products iPad iPhone iPod touch making test equipment easier to use than ever With WiPry Combo you get both a dynamic power meter and a spectrum analyzer in one Now it s possible for your phone touch or tablet to become a powerful test equipment tool that you can use on the go WiPry Combo Spectrum Analyzer Mode Spectrum Analyzer Highlights Spectru m Ana lyzer e Industry leading visualization capabilities A e Data Logging in csv format Technical Specifications lt As Mobile As You Are e Screenshots can be emailed Easiest most intuitive spectrum analyzer you ll Frequency Range 2 400 to 2 495 GHz Svern use Amplitude Range 40dBm to 20dBm Amplitude Resolution 2 0dBm Preferred Tool of the Next Resolution Bandwidth 1MHz Generation of Inventors Sweep Time 200ms WiPry Combo also enables you to visualize re Antenna External with SMB al time radio frequency signals in the 2 4GHz ISM band It is perfect for detecting open WiFi channels and identifying unauthorized WiFi access points 14 Revised November 17 2011 4 iPad iPhone iPod Section 5 How the Dynamic Power Meter Works 5 10 Menus Double clicking on the display will toggle between the menu bar and the summary bar The Menu Bar The menu bar has sub menus that can be selected by touching th
18. hat wave To clear the reference wave touch the word clear a Then touch Ga 5 30 Cursors 5 31 Cursors On Off Touch on the menu bar Touch J to activate cursors Touch Ga to turn cursors off 5 32 Cursor Axis Then touch either the HORIZONTAL cursor or the cursor Double tap the interface until the summary screen appears Metrics relating to the cursors appear in the center of the summary screen 5 33 Cursor Mode There are two modes available on this device and REGGIO Upon activating cursors two lines will appear One is dotted and the other is solid The solid line is active and can be moved while the dotted line is stationary unless the cursors are in tracking mode While in tracking mode both the solid and dotted lines will move together In independent mode the solid line is the only line that can be moved Additionally dynamic metrics related to the solid line are available in the summary screen located at the bottom measurements will be in green Touch on the dotted line 16 Revised November 17 2011 iPad iPhone iPod and it will become a movable solid line while the other line will change to dotted 5 34 Horizontal Cursors Touch the REG icon from the menu bar Touch to activate cursors Touch HORIZONTAL from the cursors menu and it will change from HORIZONTAL to Ge Touch EIB and E 10 turn the horizontal cursors on and off respectively On the main screen touch and swipe the desired
19. he screen It is not possible to retrieve screenshots from this spot and pictures are not available in photos where they can be emailed The other option is to simultaneously press both the home button and the power button on your Apple device The screen will flash white while the picture is captured When a picture is captured this way everything visible on the LCD will be captured and available in photos where it can be emailed 2 77 Manage Data Log This feature is only available with hardware it is not available in demo mode When in demo mode the data logging options START and STOP are grayed out Touch Hi from the menu bar Then touch GB from the data log option EA ae G will then change to B in order to indicate data is being logged To stop data logging touch EBB Touch Ei Then touch Qa A pick wheel will appear with all of the data that has been previously logged where it will be possible to email the raw data that has been collected 2 78 Configuration Settings Reset Configurations To reset the configuration touch Ei Then touch GEGIO Ge Saving Configurations Up to three configurations can be saved at a time Touch Then touch next to CONFIG 1 2 or 3 will then change to E in order to indicate that the configuration is saved 12 Revised November 17 2011 iPad iPhone iPod To upload a saved configuration touch MEM will then change to MEZ which confirms that the saved profile has been loaded
20. iPry Combo all include hardware along with an external antenna pictured above Each product comes with a full one year manufacturer warranty 23 Revised November 17 2011 WiPry Combo Manual 7 20 Conducted Measurement Kit An optional Conducted Measurement Kit can be purchase along side of WiPry Combo and WiPry Power Included in the kit three custom SMB Grabbers Harness SMA Adapater and RP SMA Adapter all pictured above 24 Revised November 17 2011 Section 8 Performance Specifications A O S C U M bE A 7 19 dBm Power Meter Technical Specifications Frequency Range 100 MHz to 2 7 GHz Timescale 2 us div to 1 s div Antenna External with SMB connector Amplitude Range 45dBm to 20dBm Amplitude Resolution 2 0dBm Optional Accessory kit Provides ability to make conducted measurements Power Meter Highlights e Ability to capture trigger and record the actual power output of RF amplitude e Wide frequency range 100 MHz to 2 7 GHz e Display configuration can be saved for on the go measurements e Two finger stretch zooms in and out of scaling no more buttons and knobs e Data Logging in csv format e Easiest most intuitive power meter you ll ever use e Preferred power meter for the next generation of Inventors n WiPry Combo Dynamic Power Meter Preferred Tool of the Next Generation of Inventors WiPry Combo brings the typical LCD style RF power measurements to a g
21. ings 5 72 Alerts 5 73 Persistence 5 74 Sounds 5 75 Units 5 76 Screenshot 5 77 Email 5 78 Manage Data Lo 5 79a Configuration Settings 5 79b Pause Play 5 80 Host Properties Section 6 Switching Power Mode to Spectrum Mode Section7 Product Warranty amp Accessory 7 10 Manufacturers Warranty 7 20 Optional Conducted Measurement Kit Section 8 Power Meter Performance 8 10 Detailed Specifications 8 20 Performance Optimization Section 9 How to Contact Us Section 1 Getting Started with SAFETY 1 10 WiPry Combo Quickstart Guide The quickstart guide listed below applies for both the spectrum analyzer and the dynamic power meter Quickstart Guide WIPry Combo Spectrum Analyzer amp Dynamic Power Meter 30 PIN DOCK CONNECTOR CONNECT TO APPLE DEVICE WARNING DIOR NOI Na SO THAN 20dBm TO THE ANTENNA WITHOUT 2 4GHz 2 5GHz EXTERNAL ANTENNA ATTENUATION WARNING DO NOT APPLY MORE THAN 0 5 3 8 V TO THE EXTERNAL TRIGGER EXTERNAL TRIGGER COPTIONAL 1 Connect Antenna and External Trigger Coptional to the appropriate ports 2 Download WiPry from the App Store 3 Connect accessory to the iPod touch iPhone or iPad using the 30 pin dock connector 4 For more information please visit the Oscium website WWwW OSCIUM COM Made for iPod Made for iPhone and Made for iPad means that an electronic accessory has been designed to connect specifically to iPod iPhone or iPa
22. nce between the crossing points of the two vertical cursors is indicated in the summary bar next to AdBm When using vertical cursors both Hz AHz and dBm AdBm or mW AmW will be visible in the summary bar Revised November 17 2011 7 WiPry Combo Manual iPad iPhone iPod Verify that cursors are selected To move cursors independently of one another touch MERA To move cursors as a single unit with a fixed distance between them touch GSO The following options are available SSE 1 If cursor data is to be displayed in Base touch ITS The options next to the word UNIT set the unit of time Time settings available in the Base option include RB The N option sets the unit of measure in seconds The option sets the unit of measure in hertz 2 If cursor metrics are to be displayed in Phase touch RIMINI The options next to the phrase 360 WITHIN sets the phase The option of GIS sets 360 within 5 divisions The RED option sets 360 between the two cursors 3 If cursor data is to be displayed as a ratio touch RATIO The options next to the phrase 100 WITHIN set the ratio Ratio settings available next to 100 WITHIN include BS The option of EN sets 100 within 5 divisions The BGS option sets 100 between the two cursors 2 40 Measurements Touch sea from the menu bar Four different peak measurements exist Peaks On Top Peaks Decay Peaks Avg and Peaks None To change any of the measurements
23. ne and iPod touch press and hold ES and it will change to When hardware is connected all additional settings and features are available 5 71 Grid Settings Lines vs Dots Touch Ei Then touch the desired selection either LINES or ports This setting affects the way that the signals are displayed it will either be point by point dots or it will be represented with a line Graticule Touch i Then touch lt or 6 to scroll through the various background display options They include Crosshairs Major Tics Minor Tics Major Grid Minor Grid and finally Graticule Once a selection is touched it becomes active and changes from GRATICULE to Touching graticule is a shortcut for touching all of the above 5 72 Alerts Touch kJ Three alerts are available They are located on the third row from the top ALERTS ON STARTUP amp ON DISCONNECT Cycle through the options by touching a or E next to the selection Then touch the selection to activate it To deactivate a specific alert touch the alert and it will change from GRAAL to _onsTARTUP__ Touching is a shortcut for touching all of the above 5 73 Persistence Touch Then touch and swipe the dot to the right of persist ESSE 5 74 Sounds Sounds can be controlled either through hardware or software The Apple device can control the sound in the same way it always controls sound by using the plus minus volume controls on the side of the device In the s
24. now your thoughts about our newest product WiPry The best way to reach us is at www oscium com contact Send us a technical question or just say hi Thank you for your interest in WiPry 26 Revised November 17 2011
25. oftware sounds are turned off by touching Bi Then touch E to turn sounds off or touch QQ to turn sounds on 21 Revised November 17 2011 WiPry Combo Manual 5 75 Units Touch iS from the menu bar Then touch either dem or mw next to the word MMSE Once a unit of measure has been selected it will apply to all metrics for the power meter With WiPry Combo a change in the power meter settings will transfer over to the spectrum analyzer and vice versa 5 76 Screenshot Two options exist First a screenshot can be captured by simultaneously pressing both the home button and the power button on your Apple device The screen will flash white while the picture is captured When a picture is captured this way everything visible on the LCD will be captured and available in photos The second option is to touch Ei and then touch SCREENSHOT The text SCREENSHOT will briefly fade from translucent to gray The setting menu will disappear and the display will briefly change to full screen mode Although this is a very useful method it may not always be the best way to take a screenshot By simultaneously pressing the home and the power button it is possible to take a picture of exactly what is on the screen In some cases this will be the best option 5 77 Email Touch EI Then touch CE The email will consist of the image currently displayed on the screen Although it is not possible to retrieve screenshots from this spot th
26. ouchping is a shortcut for touchping all of the above 2 73 Sounds Sounds can be controlled either through hardware or software The Apple device can control the sound in the same way it always controls sound by using the plus minus volume controls on the side of the device In the software sounds are 11 Revised November 17 2011 WiPry Combo Manual iPad iPhone iPod turned off by touchping eal Then touch SAA to turn sounds off or touch RY to turn sounds on 2 74 Units Touch i from the menu bar Then touch either dem or OW next to the word RUALEHS Once a unit of measure has been selected it will apply to all metrics for the spectrum analyzer For those that are using WiPry Combo a change in the power meter settings will transfer over to the power meter and vice versa 2 75 Screenshot Two options exist First a screenshot can be captured by simultaneously pressing both the home button and the power button on your Apple device The screen will flash white while the picture is captured When a picture is c aptured this way everything visible on the LCD will be captured and available in photos The second option is to touch E and then touch SCREENSHOT J The text SCREENSHOT will briefly fade to from translucent to gray The setting menu will disappear and the display will briefly change to full screen mode 2 76 Email Touch Then touch CE The email will consist of the image currently displayed on t
27. raphical interface showing you the waveform of the amplitude with respect to time It operates exactly like an oscilloscope but instead of showing voltage you get RF amplitude This means that you can capture trigger and record the actual power output as you would a voltage on an oscilloscope This is extremely powerful for protocol verification and troubleshooting of wireless devices With the optional conducted measurement kit WiPry Combo is also capable of con ducted measurements as well as non RF related triggering Data is collected at up to 12 MSPS allowing you to analyze and verify the smallest protocol level on off times Revised November 17 2011 hN WiPry Combo Manual 8 20 Performance Optimization Newer generations of Apple hardware will improve the Oscium customer experience Animations will be faster and crisper Multitasking can also affect performance Turning off applications will improve performance Double click the home button on your Apple device All the applications listed in this menu are currently running on the device Press and hold any icon They will begin to shake and a minus sign will appear on the top left corner of the app Touchping the minus sign will shut down the app it will not delete it from your device This will free up additional processing power on your device to maximize the user experience but it will only work on 3rd generation devices and newer Section 9 How to Contact Us Please let us k
28. s located in the menu bar on the far right side 22 Revised November 17 2011 If the signal is paused the screen will resume real time measurements by touching palati In order to capture a single shot wave form touch and hold HI or pak until it changes to e Then touch waveform Single shot waveform capture is a feature more for the dynamic power meter but if the setting is changed on and it will capture a single shot the power meter it will remain in that state on the spectrum analyzer To change it back to pause play press and hold 5 80 Host Properties From Demo Mode touch El from the bottom right corner of the menu screen to view host properties When hardware is plugged in and product is in Active Mode touch from the bottom right corner of the menu screen to view host properties Here is an example of host properties on an iPhone Host Properties Version 1 0 0 Device iPhone 4 Connection Type Supported UART USB iOS version 3 1 3 or newer is required for WiPry to operate Section 6 Switching between Power and Spectrum When using WiPry Combo with the functionality of both a spectrum analyzer and a power meter both interfaces will be active and fully functional Touch o It will then change to ala This will allow you to switch between the power interface and the spectrum interface Section 7 Product Warranty amp Accessories 7 10 Product Warranty a WiPry Spectrum WiPry Power and W
29. tivate the settings touch away from the menu or touch Back E To clear the setting touch CANCEL 10 Revised November 17 2011 iPad iPhone iPod 2 56 Min Hold Touch Zi Then touch O next to the phrase LA ia lele Eee Then select the desired setting in the pick wheel To activate the settings touch away from the menu or touch Back To clear the setting touch CANCEL 2 60 Demo Touch ral Four different settings exist NONE WiFi DECT and DSSS Once a setting is selected it will change from 2 70 Settings 2 71 Grid Settings Lines vs Dots Touch that the signals are displayed it will either be point by point dots or it will be represented with a line Graticule Touch Major Tics Minor Tics Major Grid Minor Grid and finally Graticule Once a selection is touchped it becomes active and changes from QS to Touchping graticule is a shortcut for touchping all of the above Then touch the desired selection either LINES or Dors This setting affects the way Then touch E or E to scroll through the various background display options They include Crosshairs 2 72 Alerts Touch Three alerts are available They are located on the third row from the top ALERTS ON STARTUP amp ON DISCONNECT Cycle through the options by touchping E or a next to the selection Then touch the selection to activate it To deactivate a specific alert touch the alert and it will change from RICE to EEMI T
30. w WIPry Spectrum Works 2 10 Menus The section of the manual describes how the spectrum analyzer portion of WiPry Combo works on the iPad iPhone and iPod touch iPad iPhone iPod Double clicking on the display will toggle between the menu bar and the summary bar The Menu Bar A 8 04 dBm The menu bar has sub menus that can be activated by touching the appropriate word or icon When using the iPad and hardware is not connected the following options exist in the menu bar When hardware is plugged into the iPad the demo option disappears On the iPhone iPod touch the same options exist in demo mode except that the settings option is not viewable To view settings in demo mode press and hold and it will change To toggle between spectrum analyzer mode and power meter mode touch Eg or Pd in the bottom right corner of the menu bar to change the mode 5 Revised November 17 2011 4 WiPry Combo Manual iPad iPhone iPod 2 20 Spectrum Views 2 21 Real Time View Waterfall View Touch cy on the menu bar At the top of the menu the waveform can be set to either real wave or waterfall by touchping either or ETS When activated it will change from EB to WATERFALL When real wave is selected six additional views are available Raw Decay Average Max Hold Min Hold and Heat Map To scroll through the measurement options touch SL ee Then scroll through the pick wheel to choose

Download Pdf Manuals

image

Related Search

Related Contents

50396-M-D - Lite  FDS Versión 5 - Trinaper - Aqualab  Troy-Bilt 643D, 643B Tiller User Manual      Samsung HW-J6000/ZA Specification Sheet  Gefen EXT-HDMI1.3-244 User's Manual  Milrinon Labatec® i.v. Composition Forme galénique et quantité de  Toshiba GR-H41TA Refrigerator User Manual  TECHNO VISION BASIC USER MANUAL  