SIMADYN D Digital Control System Buffer memory

image

Contents

1. Attachments 7 Attachments 7 1 Block diagram Block diagram MM3 7 2 Layout diagram Layout diagram MM3 3SE 465 611 9005 00 AO Siemens AG Dk Nr 251341 Edition 05 95 7 SIMADYN D Hardware User Manual Attachments Block diagram MM3 JOJOBUUOD UId 96 LX sng JO0J99UUO9 UIA 96 ZX sng ssaJppe pue 01 U09 e ep IUl snq 7 wou lt Y LA Y LILI LILI LIL LILLIE Lt LI Lot LI LI A Keldsip eldsip qa snjeis juewBbes 7 indino NIAGY ON eS NS yndul a Si ndul euuajuy Siemens AG Dk Nr 251341 SIMADYN D Hardware User Manual Edition 05 95 ECB instructions 8 ECB instructions Components which can be destroyed by electrostatic discharge ECB Generally electronic boards should only be touched when absolutely necessary The human body must be electrically discharged before touching an electronic board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contact with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man
2. aes Lie tact 6 5 3 Ud ode lod 6 6 STRUGE mask of the MM reed 6 fs A oO 7 FV TA SO 7 2 FAyOut Magram siysecet vets tateatveteh a e Muecer aetna eta aneded Adal Mune 7 e EGB INSTITUCION it o fa dd ee ast teeta tats 2a a o fae 9 Siemens AG Dk Nr 251341 Edition 05 95 SIMADYN D Hardware User Manual Warning information Edition 05 95 Siemens AG Dk Nr 251341 SIMADYN D Hardware User Manual Warning information NOTE The information in this Manual does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes please contact your local Siemens office Further the contents of this Manual shall not become a part of or modify any prior or existing agreement committment or relationship The sales contract contains the entire obligation of Siemens The warranty contained in the contract between the parties is the sole warranty of Siemens Any statements contained herein do not create new warranties nor modify the existing warranty Warning information WARNING Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and material damage can result Only appropriately qualified person
3. includes two memory blocks each 64 kbyte a 16 bit microprocessor 80C186 8MHz which decodes the time signals the associated peripherals and a 2 kbyte dual port RAM Each of the two buffer memory blocks is 64 kbyte and has a 32 k 16 organization One buffer memory area can be accessed via the L bus and the other via the C bus Access is either bytewise or wordwise The processor board which is inserted to the left of the buffer memory board initializes and checks both buffer memories MM3 must be configured so that it is located next to the first processor module i e at slot 3 The MM3 buffer memory module has no bus termination The integrated clock module counts the time independent of other components is quartz clocked and buffered from the rack battery so that the the time is continually updated even if the subrack is not operational The integrated processor ensures that the time in this block is as accurate as possible If a time signal is available this is decoded and the internal clock is synchronized Presently one of two different time signals is used for synchronization this is defined in the STRUC mask when configuring the system The first signal is the so called DCF 77 radio signal which can be received everywhere in central Europe An external antenna is required as the rooms in which SIMADYN D is used are generally screened or accomodate noise emitting equipment The external antenna must be mounted outside the
4. room and oriented towards Frankfurt Main where the time signal transmitter is located The direction is specified on the antenna housing The antenna is connected using BNC socket X7 on the front panel The second signal is the audible IRIG B signal which is transmitted via cable This signal is especially used in USA and Canada but can also be used in other regions when special generators are used In this case high precision clocks can be used as time transmitter however the accuracy can be somewhat less than for the DCF 77 radio signal Socket X6 is provided on the front panel for connecting the IRIG B signal cable The time is indicated on a 7 segment LED displays on the front panel They are mounted horizontally The following is displayed from the top to the bottom Date day of the month and month and time hours minutes and seconds A flashing display indicates that the time might be incorrect e g after switch on The time can also be manually set Two buttons are used on the front panel The cursor is moved with the upper key identified by a flashing display A one is added to the value at the cursor position with the lower key for seconds the value is set to zero Siemens AG Dk Nr 251341 Edition 05 95 3 SIMADYN D Hardware User Manual Notes 1 For the DCF 77 signal the time telegram lasts one minute thus the display can flash for up to two minutes even for perfect receptions until the complete telegram has be
5. SIMADYN D User Manual Digital Control System Buffer memory module MM3 Edition 05 95 DK Nr 251341 User Manual Buffer memory module MM3 E ES Buffer memory module MM3 02 93 Buffer memory module MM3 09 94 Buffer memory module MM3 05 95 Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Warning MAIN id dean abe dto Aled dada at ta 1 DADA NN e tdo E 3 2 FUNCION descriptor dia labels 3 21 General noma tidad dd diras 3 Si Boardidesignws titan thet alt tada fli S 5 4 Important application information ooooncccccnnnnaccccnnnannn connnnncnnnn cnn cnn anna nc conan nn anna nan n nn nn nan nn nana 5 A E datas sticciei dine eat bite tates a a nal te bake cal a 4 Bib 6 5 12 Generalintormato Meisi id erat i cata 6 5 2 POWer SUD title ceo edo dobla ace ns la todo ecos DEl cece
6. en received 2 The standard IRIG B signal unfortunately does not contain clear information regarding the date but only the sequence of the days in the year no differentiation as far as a leap year is conccerned Thus date information could be incorrect This is also identified by a flashing display and must be corrected using the keys 3 The board is initialized from processor 1 This is realized at run up in the rack if the MM3 was configured in the master program Only then is the buffer memory enabled and the time displayed at the front panel The time is transferred to the dual port RAM only accessible from the L bus The time can be read out of the dual port RAM This is realized by the RTC001 function block As far as the functional scope is concerned this replaces the existing RTC block For more information refer to the module catalog LEDs H20 H23 are provided on the front panel They indicate the status of the time receiver The individual LEDs have the following significance H20 green The board is initialized for receiving DF77 signals 7 The board is initializied for receiving IRIG B signals H21 flashes every The time signal is being received a Hit Signal has no information check signal cable H22 green j The time signal does not contain correct information lit The information comes minimum of 10 seconds in the correct format H23 red Error in the time telegram Decoding running The MM3 routes
7. made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ECB protective measures are clearly shown in the following diagram a Conductive floor surface d ECB overall b ECB table e ECB chain c ECB shoes f Cubicle ground connection Siemens AG Dk Nr 251341 Edition 05 95 9 SIMADYN D Hardware User Manual ECB instructions 10 Edition 05 95 Siemens AG Dk Nr 251341 SIMADYN D Hardware User Manual ECB instructions Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen System Based Technology Siemens AG Dk Nr 251341 Edition 05 95 11 SIMADYN D Hardware User Manual
8. nel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The successful and safe operation of this equipment is dependent on prope handling installation operation and maintenance Siemens AG Dk Nr 251341 Edition 05 95 1 SIMADYN D Hardware User Manual Warning information Definitions QUALIFIED PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment in accordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicate
9. s that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the User Manual which is essential to highlight CAUTION This board contains components which can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 05 95 Siemens AG Dk Nr 251341 SIMADYN D Hardware User Manual Ordering information 1 Ordering information MM3 6DD 1611 0AFO Antenna for inside use Hopf Elektronik Nottebohmstr 41 58511 L denscheid FG443610 internal antenna 4436 Long Distance Antenna for external use Hopf Elektronik Nottebohmstr 41 58511 L denschaid FG441800 external antenna 4418 2 Function description 2 1 General information Board MM3 is used in the SIMADYN D system for processor board data transfer and real time counting It
10. t application information The MM3 buffer memory board may only be used in a SIMADYN D subrack The subracks must be equipped with bus terminating modules The board must be tightly screwed into the subrack to ensure perfect operation even during start up If the board is inserted in an adapter for test purposes the front panel must be connected to the housing through a short cable It is not permissible that the board is either inserted or withdrawn with the subrack power supply switched in Siemens AG Dk Nr 251341 Edition 05 95 5 SIMADYN D Hardware User Manual Technical data 5 Technical data 5 1 General information Insulation group DC Ambient temperature Storage temperature Humidity rating Altitude rating Mechanical stressing Packaging system Dimensions Board width Weight 5 2 Power supply A acc to VDE 0110 13 Group 2 at 24 V DC 15V DC 5V 0 to 55 degrees C 40 to 70 degrees C F acc to DIN 40050 S acc to DIN 40040 Installation in stationary equipment which is not necessarily vibration free ES 902 C 233 4 mm 220 mm 1 slot 20 14 mm approx 700 y Potential Rated voltage 4 75 V 5 25 V 14 4 V 15 6 V VCCR 5 3 Current drain 600 mA 0 02 mA 6 STRUC mask of the MM3 MM3 Radio clock with L C bus buffer memory SiIGIG 0 Signal type 0 DCF 77 1 IRIG B 2 TIM1K lt Real time clock 6 Edition 05 95 Siemens AG Dk Nr 251341 SIMADYN D Hardware User Manual
11. the RDYIN signal externally This line can also be activated from the processor modules This is realized by connector X5 on the board Relay contacts are connected here and thus the output is electrically isolated The relay contacts are closed in the operating status and are open for at least 100 ms if a fault condition develops even with the subrack switched out The voltage at the relay contacts may not exceed 60 V During switching the current must not exceed 0 5 A and the maximum switching capability is 20 W The double test socket for the reset signal X10 X11 is used to reset the internal processor and may not be used during operation 4 Edition 05 95 Siemens AG Dk Nr 251341 SIMADYN D Hardware User Manual Board design 3 Board design The MM3 buffer memory board has the following features Local and communications bus connection L and C bus each with 96 pin connector ES902C with SIMADYN D control bus assignment 64 Kbyte RAM for the local bus 64 Kbyte RAM for the communications bus Time buffering using the subrack back up battery Dual port RAM for transferring time if 10 7 segment LED displays for time H1 to H10 Format Day month hour minutes seconds 2 keys for manually setting the clock if a time signal is not used 4 LEDs for status displays H20 to H23 Relay contacts for the system error signal X5 1 double test socket for the reset signal X10 X11 for resetting the board 4 Importan