Home
AirWorks AWK-3121 User`s Manual
Contents
1. Advance Encryption System is enabled Mixed Provides TKIP broadcast key and TKIP AES unicast key for some legacy Client This option is rarely used This option is available in AP Master mode only and does not support AES enabled clients Passphrase 8 to 63 characters Master key to generate keys for encryption and decryption Key renewal for AP Master mode only 60 to 86400 seconds Specifies the time period of group key renewal 3600 seconds 1 minute to 1 day NOTE The key renewal value dictates how often the wireless AP encryption keys should be changed The security level is generally higher if you set the key renewal value to a shorter number which forces the encryption keys to be changed more frequently The default value is 3600 seconds 6 minutes Longer time periods can be considered if the line is not very busy 3 13 AirWorks AWK 3121 Web Console Configuration WPA WPA2 Enterprise for AP Master mode By setting WPA type to Enterprise you can use EAP Extensible Authentication Protocol a framework authentication protocol used by 802 1X to provide network authentication In these Enterprise level security modes a back end RADIUS Remote Authentication Dial n User Service server is needed if IEEE 802 1X functionality is enabled in WPA WPA2 The IEEE 802 1X protocol also offers the possibility of carrying out an efficient connection authentication on a large scale network It is not necessary to exchange
2. AWK 3121 supports EEE802 1D Spanning Tree Protocol and EEE802 1w Rapid STP standards In addition to eliminating unexpected path looping STP RSTP can provide a backup path recovery if a wired wireless path fails accidentally The reliability and availability can increase because this fail over function AWK 3121 s STP RSTP feature is disabled by default To be completely effective you must enable RSTP STP on every AWK 3121 connected to your network If AWK 3121 plays a Client role which is connected to a device PLC RTU etc as opposed to network switch equipment it is not necessary to enable STP RSTP The reason is that it will cause unnecessary negotiation AWK 3121s support STP RSTP in AP mode including WDS only The following figures indicate which Spanning Tree Protocol parameters can be configured A more detailed explanation of each parameter is given below the figure RSTP Settings AP only RSTP status Bridge priority 22768 Hello time 2 1 10 seconds Forwarding delay 15 4230 seconds Max age 20 6 40 seconds T Edge port 1 LAN E 128 Y 200000 Mn AP E 128 Y 12000000 m DS 1 C 128 Y 2000000 C RSTP status Mo l Enable RSTP Port priority Port cost Status Z 3 This field will appear only when selected to operate STP RSTP It indicates whether this AWK 3121 is the Root of the Spanning Tree the root is determined automatically or not Bridge priority Setting Description Factory
3. Step 2 Select certificate key file Browse Upload Certificate File NOTE The WLAN certificate will remain after the AWK 3121 reboots Even though it is expired it can still be seen on the Current Certificate Advanced Settings Several advanced functions are available to increase the functionality of your AWK 3121 and wireless network system A VLAN is a collection of clients and hosts grouped together as if they were connected to the broadcast domains in a layer 2 network The DHCP server helps you deploy wireless clients efficiently Packet filters provide security mechanisms such as firewalls in different network layers Moreover the AWK 3121 can support STP RSTP protocol to increase reliability across the entire network and SNMP support can make network management easier 3 21 AirWorks AWK 3121 Web Console Configuration Using Virtual LAN Setting up Virtual LANs VLANs on your AWK series increases the efficiency of your network by dividing the LAN into logical segments as opposed to physical segments In general VLANs are easier to manage The Virtual LAN VLAN Concept What is a VLAN A virtual LAN commonly known as a VLAN is a group of hosts with a common set of requirements that communicate as if they were attached to the same broadcast domain regardless of their physical location A VLAN has the same attributes as a physical LAN but it allows for end stations to be grouped together even if they are n
4. Specifies the transmission distance or max range between two 500 for transmission AWK devices This parameter should be set properly especially 500 to 10000 m for long distance communication Noise protection Enable Disable Adjusts the interference coping capability of the wireless signal Disable This option should be enabled for communication distance under 500 meters and should be disabled for communication distances over 500 meters Transmission enhancement Enable Disable This setting can enhance communication by strengthening the Disable AWK 3121 s transmission power It is quite useful for long distance transmission or countering environmental interference The user must carefully evaluate and measure the transmission power of the entire system to ensure it stays below the regulative limit In addition that RF type 802 11la mode cannot be used if this function is enabled NOTE When Transmission enhancement is enabled the Tx Power is at Full RF type B G Mixed Channel1 13 e US model 22 dB e EU model 20 dB e JP model 20 dB RF type A Channel 36 48 e US model 17 dB e EU model 17 dB e JP model 17 dB NOTE Make sure the same Transmission distance parameters are set in both AP and Client sides and both Bridges When this parameter is greater than 500 an optimal algorithm will be enabled to support long distance transmission Note that Transmission enhancement only supports 80
5. 72 dBm 48 Mbps 70 dBm 54 Mbps 802 11a 87 dBm 6 Mbps 86 dBm 9 Mbps 85 dBm 12 Mbps 82 dBm 18 Mbps 80 dBm 24 Mbps 76 dBm 36 Mbps 72 dBm 48 Mbps 70 dBm 54 Mbps Protocol Support General Protocols Proxy ARP DNS HTTP HTTPS IP ICMP SNTP TCP UDP RADIUS SNMP PPPoE DHCP AP only Protocols ARP BOOTP DHCP dynamic VLAN Tags for 802 1X Clients STP RSTP IEEE 802 1D w Interface Default Antenna 2 dBi dual band omni directional antenna RP SMA male Connector for External Antennas RP SMA female LAN Ports 1 10 100BaseT X auto negotiation speed RJ 45 type Console for External Antenna RS 232 RJ 45 type LED Indicators PWR1 PWR2 PoE FAULT STATE signal strength CLIENT MODE BRIDGE MODE WLAN 10M 100M Alarm Contact 1 relay output with current carrying capacity of 1 A 24 VDC Digital Inputs 2 electrically isolated inputs e 13 to 30 V for state 1 e 3 to 30 V for state 0 e Max input current 8 mA Physical Characteristics Housing Metal providing IP30 protection Weight 850 g Dimensions 53 6 x 135 x 105 mm 2 11 x 5 31 x 4 13 in Installation DIN Rail mounting wall mounting with optional kit Environmental Limits Operating Temperature Standard Models 25 to 60 C 32 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Power Requireme
6. for V1 V2c V3 and V3 only DES based data encryption AES based data encryption Private key A data encryption key is the minimum requirement for data encryption maximum of 63 characters Private MIB Information Device Object ID Also know as OID This is the AWK 3121 s enterprise value It is fixed Link Fault Pass Through for Client Slave mode only This function means if Ethernet port is link down wireless connection will be forced to disconnect Once Ethernet link is recovered AWK will try to connect to AP If wireless is disconnected AWK restarts auto negotiation on Ethernet port but always stays in the link failure state Once the wireless connection is recovered AWK will try to recover the Ethernet link System log will indicate the link fault pass through events in addition to the original link up down events Link Fault Pass Through for Client Slave mode only Link Fault Pass Through Enable Disable Link Fault Pass Through Enables Link Fault Pass Through Disable Disable Link Fault Pass Through 3 31 AirWorks AWK 3121 Web Console Configuration Auto Warning Settings Since industrial grade devices are often located at the endpoints of a system these devices will not always know what is happening elsewhere on the network This means that these devices including wireless APs or clients must provide system maintainers with real time alarm messages Even when system administrators
7. or Internet resource and Windows will open it for you Oper telnet 192 168 127 293 Cancel Browse 2 When using SSH client ex PuTTY please run the client program ex putty exe and then input the AWK 3121 s IP address specifying 22 for the SSH connection port i PuTTY Configuration x Categor Fl Session Basic options for your Pul Ty session Lagging a Es Terminal specity the destination you wantto connectto Keyboard Host Name or IF address a Bell f 927 168 127 253 a E i bel Connection type Po Baw Telnet Rlogin SSH Serial Appearance 3 The Console login screen will appear Please refer to the previous paragraph RS 232 Console Configuration and for login and administration Configuration by Web Browser with HTTPS SSL To secure your HTTP access the AWK 3121 supports HTTPS SSL encryption for all HTTP traffic Perform the following steps to access the AWK 3121 s web browser interface via HTTPS SSL 1 Open your web browser and type https lt AWK 3121 s IP address gt in the address field Press Enter to establish the connection J https 77192 168 127 253 home asp Microsoft Internet Explorer File Edt View Favorites Tools Help Address https 192 168 127 253 home asp 2 Warning messages will pop out to warn users that the security certificate was issued by a company they have not chosen to trust Security Alert E Infor
8. 21 0D 99 1 BSS OPENH 2000 3 default O0 15 F2 A2 07 64 1 BSS OPEN 20001 4 BLW 54PM O0 90 Co D 6 B5 20 6 BSS WEP 2000 5 BLW 54PM 00 930 CC D6 BC EC 6 BSS OPEN 20001 6 ZyXEL O0 19 CB 41 48 94 1i BSS WEP 2000 7 O0 16 01 80 11 7F 1i BSS OPEN 200 8 HJ wWireless 00 16 01 EC D0 61 2 BSS WEP anll 3 default 00 40 05 56 9D B1 8 BSS WEP 2000 10 hpsetup 52 BC 90 E2 84 14 10 Ad Hog OPEN anall Refresh Close Pe ETA A E If the Gateway field in Basic Settings gt Network Settings is empty a warning message will appear reminding you to set the default gateway when Client mode is enabled You can ignore this message if you are only planning a local network and packets will not be sent outside the network 3 9 AirWorks AWK 3121 Web Console Configuration Supports EEE802 11a standard only B G Mixed Bo Supports EEE802 11b standard only Supports EEE802 11g standard only B G Mixed Supports both of EEE802 11b g standards but 802 11g can be Slowed down when 802 11b clients are on the network Channel for AP Master mode only Available channels vary AWK 3121 plays a role of wireless AP 6 in B G Mixed with RF type mode Factory Default Max of 31 characters The SSID of a client and the SSID of the AP must be identical for MOXA the client and AP to be able to communicate with each other SSID broadcast for AP Master mode only Enable Disable SSID can be broadcast or not NOTE The AWK 3121 J P for Japanese
9. 21m 31s Client 00 13 CE E1 EE EF joined 126 2008 06 18 21h 26m 05s System restart 127 2008 06 18 21h 26m 14s Power 1 transition Of gt On 128 2008 06 18 21h 26m 14s LAN link on 129 2008 06 18 21h 26m 18s Client 00 13 CE E1 EE EF joined 130 2008 06 18 21h 26m 33s Client 00 13 CE E1 EE EF joined 131 2008 06 18 21h 2 m 22s8 Client 00 13 CE E1 EE EF leaved 132 2008 06 18 21h 28m i2es Client 00 13 CE E1 EE EF joined 133 2008 06 18 21h 28m 51s Client 00 13 CE E1 EE EF joined Export Lag Clear Lag Refresh Relay Status The status of user configurable events can be found under Relay Status The status will refresh every 5 seconds if the Auto refresh box is checked If an event is triggered it will be noted on this list System administrators can click Acknowledge Event when he has acknowledged the event and addressed it Relay Status Y Auto refresh Relay Status Powerl transition On gt Off Power2 transition On gt 0ff PoE transition On gt Off DI1 transition On gt Off DI1 transition Off gt On DI transition On gt Off DI transition Off gt On LAN link On LAN link Off 3 38 AirWorks AWK 3121 Web Console Configuration DI and Power Status The status of power inputs and digital inputs is shown on this web page The status will refresh every 5 seconds if the Auto refresh box is checked Din and Power status M Auto refresh Input s
10. Default Numerical value You can increase the bridge priority by selecting a lower 32768 selected number A higher bridge priority brings a greater chance of by user being established as the root of the Spanning Tree topology Hello time Numerical value input The root of the Spanning Tree topology periodically sends out a 2 seconds by user hello message to other devices on the network to check if the 1 10 seconds topology is healthy Hello time indicates how often the root sends hello messages Forwarding delay Numerical value input The amount of time this device waits before checking to see if it 15 seconds by user should change to a different topology 4 30 seconds Max age Numerical value input As a non root role if the device has not received a hello 20 seconds by user message from the root longer than Max age it will reconfigure 6 40 seconds itself as a root Once two or more devices on the network are recognized as a root the devices will renegotiate to set up a new Spanning Tree topology 3 28 AirWorks AWK 3121 Web Console Configuration NOTE The AWK 3121 comes with 10 ports for RSTP settings Numbers 3 10 WDS1 WDS8 are available only when WDS is enabled in AP mode Enable RSTP Enable disable Enables or disables the port as a node on the Spanning Tree Disable topology unchecked Port priority Setting Description Factory Default Numerical val
11. ID Set the management VLAN of this AWK ranges from 1 to 4094 Port Trunk Port LAN ss This port is the LAN port on the AWK Yes This is a wireless port for the specific SSID This field will refer to the SSID that you have created If more SSIDs have been created new rows will be added Port PVID VLAN ID ranging from 1 Set the port s VLAN ID for devices that connect to the port The 1 to 4094 port can be a LAN port or WLAN ports VLAN Tagged A comma seperated list Specify which VLANs can communicate with this specific VLAN of VLAN IDs Each of the VLAN IDs range from 1 to 4094 The VLAN feature can allow wireless clients to manage the AP If the VLAN Management ID matches a VLAN ID then those wireless clients who are members of that VLAN will have AP management access CAUTION Once a VLAN Management ID is configured and is equivalent to one of the VLAN IDs on the AP all members of that User VLAN will have management access to the AP Be careful to restrict VLAN membership to those with legitimate access to the AP 3 23 AirWorks AWK 3121 Web Console Configuration DHCP Server for AP mode only DHCP Dynamic Host Configuration Protocol is a networking protocol that allows administrators to assign temporary IP addresses to network computers by leasing an IP address to a user for a limited amount of time instead of assigning permanent IP addresses The AWK 3121 can act as a simplified DHCP s
12. Refresh ll Ex No Modelname IP address Device MAC address Firmware versio ay awest27Us 168 127 253 00 90 E8 00 00 01 255 255 255 0 EEE System info Device info 802 11 info Model name AMWE 3121 U5 Device name AWE 3121_ 9390 Serial No 3390 System up time O days 00h D0m 51 2 Firmware version 1 2 Build 09052501 Click Assign IP to change the IP setting AWK Search Utility Sele Ele Edit Function Tools Help i E E gt p search Search Ex Locate hud Unlock Upgrade Refresh Refresh All No Hodelname Paade Lt Device MAC address _ Firmware versio Ei AWK 3127 U5 En 168 127 253 System info Device info 802 11 info Model name AWE 3721 U5 IP configuration Device name AWE 3121_ 9390 serial No 3390 Beie System up time O days 00h 00m 51s Firmware version 1 2 Build 09052501 Subnet mask Gateway Primary ONS server Secondary ONS server w OK X Cancel 4 7 AirWorks AWK 3121 Software Installation and Configuration The three advanced options Search Connection and Miscellaneous are explained below Search Retry count default 5 Indicates how many times the search will be retried automatically e Retry interval ms The time lapsed between retries Advanced Options search Connection Misc Retry count 5 Retry interval ma O00 f Ob aE Cancel Connection Connection timeout secs Use this option to set the waiting time for the De
13. UII CS alerts AAA o aaa 3 11 Advanced Wireless Settings ccccccc cece cee ener renee en en ne EE EE eed DEAE E A EES DEES E EE SEE EEE ESS SEE SEES ESSE SEER EE GEEES 3 17 WLAN Certification Settings for EAP TLS in Client mode only ccccceceee eee eeeee eee eeeeeeeeeeeseneeeeeesgnnes 3 21 Advanced A A O a a CO Ci A assests 3 21 SING Virta kA N a Soak e e AAA AAA ddan dead aa NAO Da IAO 3 22 COnNNOUTNO VI USAN REA ASAS AA DO RARA BANAAN A 3 23 DHCP Server for AP Mode only ooccoocccccccccccccccccnnnnncnncn rn rr 3 24 P E o ni O E A A A ES 3 25 RSTP Settings for WDS M ste sor Slave Only cuado 3 28 SNMP AGOMEA seSvtenie ches cnet ac teed cde er ele ae 3 29 Link Fault Pass Through for Client Slave mode only cccccceecceee cece cece eee eeeeeeeeeeeseeeeeeeegeaneeeeeagganes 3 31 Auto Warning im 1 80 a ae 3 32 Sn nama A cme manatee mat ateat tater 3 32 Otc Hee AR 3 33 AGA Renee ea eee RCE ee Ree ee ee en eee Ia 3 34 REIA tt errr rrr errr rr rere eT errr errr Teer terre rene eer eee eee errr seer errr ere cert rer ner errr er ere er ere 3 35 AA o q TRG TRA RG RA BATRA TRA TI Bias bos Dios ios Dies Dios Dios bios ics bios bie bey bia di ae 3 35 Sis See ee a ee ee ee ee ee ee Ce T ee ee ene meee ene ee nn nn eee a nen ern ae en ee ree 3 37 MUN CIES SS CWS rte cans oe ona abe ee es eye acu an E aa 2 an aan ce ama SUN Ee ca 3 37 Associated Client LIST Mor AFP MOdE Only a A A AAA 3 37 DACP CI NELISE or AP mode Only
14. Wi Fi Protected Access and WPA2 represent significant improvements over the WEP encryption method WPA is a security standard based on 802 11i draft 3 while WPA2 is based on the fully ratified version of 802 11i The initial vector is transmitted encrypted and enhanced with its 48 bits twice as long as WEP The key is regularly changed so that true session is secured Even though AES encryption is only included in the WPA2 standard it is widely available in the WPA security mode of some wireless APs and clients as well The AWK 3121 also supports AES algorithms in WPA and WPA2 for better compatibility Personal versions of WPA WPA2 also know as WPA WPA PSK Pre Shared Key provide a simple way of encrypting a wireless connection for high confidentiality A Passphrase is used as a basis for encryption methods or cipher types in a WLAN connection The passphrases should be complicated and as long as possible There must be at least 80f ASCII characters in the Passphrase and it could go up to 63 For security reasons this passphrase should only be disclosed to users who need it and it should be changed regularly WLAN Security Settings Security mode WPA WPA type Personal Encryption method TKIP Passphrase Key renewal 60 86400 second Provides Pre Shared Key enabled WPA and WPA2 Personal Provides enterprise level security for WPA and WPA2 Encryption method TKIP Temporal Key Integrity Protocol is enabled TKIP
15. default user name and password and then click on the Login button Web Console Login Username admin Password Login goahead WEBSERVER NOTE Default user name and password User Name admin Password root For security reasons we strongly recommend changing the default password To do so select Maintenance gt Password and then follow the on screen instructions to change the password 2 2 AirWorks AWK 3121 Getting Started NOTE After you click Submit to apply changes the web page will refresh Updated will appear on the page and a blinking reminder will be shown on the upper right corner of the web page sis ota A Weel ux oe lt LL ys gt Total Solution for Industrial Wireless Networking J Main Menu E Overview System Info Settings Updated To activate the changes click Restart and then Save and Restart after you change the settings About 30 seconds are needed for the AWK 3121 to complete the reboot procedure e Step 5 Select the AWK 3121 operation mode By default the AWK 3121 s operation mode is set to AP You can change to Client mode in Wireless Settings gt Basic Wireless Settings Detailed information about configuring the AWK 3121 s operation can be found in Chapter 3 e Step 6 Test communications In the following sections we describe two test methods that can be used to ensure that a network connection has been established Communication Testing After installing the AWK 31
16. es AN NM NANNA W M N a M a EA e MEAN E SEE 3 37 o ieri a a A E E E nan D A AE AAAA AAAA AAAA AA AAAA EEOAE A 3 38 Relay CaS au E A E E E A aa 3 38 PD zeit Cl POW Sie Status os we ts so ts so see og SES 3 39 Malntena tanta vation aden Rue en OEA TL AS AOS DA AO ec 3 39 CONSOLA OS ee ee cen A rete 3 39 ic ee rrr ere 3 39 Firmware O eed edad eee aad eae aedial dud aeadedes 3 40 CONTADOR EXDO adem pred eee a eer eee een A A aaa 3 40 Load Factory Der asia aa NOD a eco 3 41 A A O esta a 3 41 IVINS Gs SUE Se bi 3 42 Save COn Uat wits ee a a A adadda ida aaa aad aad begduasetanieeaeadae 3 42 RR RN O 3 43 e eer rere Stet ey eee ere ere eer ee rene er er eer ter eer rer ker ker rer eer eer eee eer reer eee er rey 3 43 4 Software Installation and Configuration coccion cis 4 1 O oo Etoo IRIS 4 2 E en ence es IEO AI EE eee eee 4 2 PAstalling AVVK S Carch UE ada adudaludscteaceaaens 4 2 COnfGUEING AWK Search UEM ES Sedo 4 5 5 Other Console Considerations ii aa ad a A A AA A 5 1 RS 232 Console Configuration 115200 None 8 1 VT100 000ccccccccncccccccnnnncnncrn cnn cnn rr rr 5 2 Conriguravion by lelnettcana SSH COMO curs E AAGas 5 3 Configuration by Web Browser with ATT SS as 5 4 Disabling Temet and BrOwWSer ACCESS iina a E i E E E E EE A AEE SNA 5 5 As RETENC ES A AAA A 1 Wireless Distriputiom System WDS ireas aE AATRE AEE A RA ee aE ORA R A aT A R AAAA AEA A 2 E A E a a a he Rene rere eer eee Per enere here ny A 3 E ren tet
17. frequency bands only connects SSI D hidden APs in all EEE802 11a channels and EEE802 11g channels 1 to 11 The AWK 3121 EU for European frequency bands only connects SSID hidden APs in all EEE802 11b g channels WDS for AP mode only Enable Disable AWK 3121 supports WDS or not NOTE When WDS is enabled you can use a pure point to point WDS link by disabling AP functionality The AWK 3121 provides 8 entities for WDS settings and can support up to 8 WDS links to other APs or wireless bridges The list appears when WDS Enable is checked Enter the MAC address to set up a WDS link Remember to activate a WDS link by checking the Active check box SSID broadcast 2 Enable Disable WDS Enable Disable AP functionality 2 Enable Disable WDS Settings No Active MAC address WDS1 WDS2 WDS3 WDS4 3 10 AirWorks AWK 3121 Web Console Configuration WLAN Security Settings The AWK 3121 provides four standardized wireless security modes Open WEP Wired Equivalent Privacy WPA Wi Fi Protected Access and WPA2 Several security modes are available in the AWK 3121 by selecting Security mode and WPA type Open No authentication no data encryption WEP Static WEP Wired Equivalent Privacy keys must be configured manually WPA WPA2 Personal Also known as WPA WPA2 PSK You will need to specify the Pre Shared Key in the Passphrase field which will be used by the TKIP or AES engine as a master key to generate keys t
18. index The selected key setting specifies the key to be used as a send key for encrypting traffic from the AP side to the wireless client side All 4 WEP keys are used as receive keys to decrypt traffic from the wireless client side to the AP side The WEP key can be presented in two Key types HEX and ASCII Each ASCII character has 8 bits so a 40 bit or 64 bit WEP key contains 5 characters and a 104 bit or 128 bit key has 13 characters In hex each character uses 4 bits so a 40 bit key has 10 hex characters and a 128 bit key has 26 characters WLAN Security Settings Security mode Authentication type Key type HE Key length key index WEP key 1 WEP key 2 ey WEP key 3 A WEP key 4 A Authentication type Factory Default Data encryption is enabled but without authentication Open Data encryption and authentication are both enabled Factory Default Specifies WEP keys in hex decimal number form Specifies WEP keys in ASCII form Key length 64 bits Uses 40 bit secret keys with 24 bit initialization vector 64 bits 128 bits Uses 104 bit secret key with 24 bit initialization vector Key index 1 4 Specifies which WEP key is used WEP key 1 4 ASCII type A string that can be used as a WEP seed for the RC4 encryption None 64 bits 5 chars engine 128 bits 13chars HEX type 64 bits 10 hex chars 128 bits 26 hex chars 3 12 AirWorks AWK 3121 Web Console Configuration WPA WPA2 Personal WPA
19. keys or passphrases WLAN Security Settings Security mode wpa y WPA type Enterprise Encryption method mixed Primary RADIUS server IP es Primary RADIUS server port Primary RADIUS shared key Secondary RADIUS server IP Secondary RADIUS server port igiz Secondary RADIUS shared key Key renewal 3600 60 86400 seconds WPA type Provides Pre Shared Key enabled WPA and WPA2 Personal Provides enterprise level security for WPA and WPA2 Encryption method TKIP Temporal Key Integrity Protocol is enabled TKIP Advance Encryption System is enabled Mixed Provides TKIP broadcast key and TKIP AES unicast key for some legacy Client This option is rarely used This option is available in AP Master mode only and cannot support AES enabled clients Primary Secondary RADIUS server IP The IP address of Specifies the delegated RADIUS server for EAP None RADIUS server Primary Secondary RADIUS port Factory Default Port number Specifies the port number of the delegated RADIUS server 1812 Primary Secondary RADIUS shared key Factory Default Max of 31 characters The secret key shared between AP and RADIUS server None Key renewal 60 to 86400 seconds Specifies the time period of group key renewal 3600 seconds 1 minute to 1 year 3 14 AirWorks AWK 3121 Web Console Configuration WPA WPA2 Enterprise for Client Slave mode When used as a client the AWK 3121 can support three EAP metho
20. known as Personal Information Exchange Syntax Standard certificate formats that define file formats commonly used to store private keys with accompanying public key certificates protected with a password based symmetric key WLAN Certificate Settings Import for EAP TLS in Client mode only Current status Certificate issued to Certificate issued by Certificate expiration date Current Status displays information for the current WLAN certificate which has been imported into the AWK 3121 Nothing will be shown if a certificate is not available Certificate issued to Shows the certificate user Certificate issued by Shows the certificate issuer Certificate expiration date ndicates when the certificate has expired You can import a new WLAN certificate in Import WLAN Certificate by following these steps in order 1 Input the corresponding password or key in the Certificate private password field and then click Submit to set the password 2 The password will be displayed in the Certificate private password field Click on the Browse button in Select certificate key file and select the certificate file 3 Click Upload Certificate File to import the certificate file If the import succeeds you can see the information uploaded in Current Certificate If it fails you may need to return to step 1 to set the password correctly and then import the certificate file again Step 1 Certificate private password Submit
21. tree rere errr ret eee rere er rte n nce E E eL tt Tet Ort tnte nny A 3 Fragment ic ciciciekcietcieh dei diei dei dei diei dean teai teas teen teas tenn tenia career a ea rna ra Dena rna ru An ru ru Trn a aa ni A 3 A O A 3 SS ONU rain EEEE A 4 The Ss TR PRS TP Concept id eae be dada N A 4 Differences between RSTP and STO e E te tt alta diane A 4 B Supporting TATED ENON hia aout msm A a is as B 1 FA 91616 TMS USES sac B 2 Doc Declaration Of CONTO PAU seminal e hadeuuduae B 2 Federal Communication Commission Interference Statement ssssrsesrrrssrrrrerrrreerrrrsrrrrerrrreerrreerrn B 2 RSTTE Complance Statemehierace east heeded erie weer i dis iii daoo B 3 FW are RECO Vo oa dr do aa B 4 1 Introduction The AirWorks AWK 3121 enables wireless users to access network resources wirelessly The AWK 3121 is rated to operate at temperatures ranging from O to 60 C for standard models and 40 to 75 C for wide temperature models and is rugged enough for any harsh industrial environment The following topics are covered in this chapter O Overview Package Checklist Product Features Product Specifications n Functional Design gt LED Indicators gt Beeper gt Reset Button gt Relay Digital Output AirWorks AWK 3121 Introduction Overview The AWK 3121 Access Point is ideal for applications that are hard to wire too expensive to wire or use mobile equipment that connects to a TCP IP network Th
22. wireless links are specified by the EEE802 11 standard e STA AP This type of wireless link is established between an EEE802 11 Station STA and an EEE802 11 Access Point AP An STA is usually a client computer PC or PDA with a WLAN network interface card NIC The Client mode is actually an STA e WDS This type of wireless link is established between two IEEE802 11 APs Wireless packets transmitted along the WDS link comply with the EEE802 11 WDS Wireless Distribution System format at the link layer Refer to the Wireless Distribution System WDS section in Chapter 5 for details Keep in mind that WPA WPA2 CANNOT be supported in WDS To establish a static bridge link based on the WDS the APs at both end of the WDS link must be configured manually with each other s MAC addresses To establish a dynamic bridge link between an AP and a Client both devices must be configured with the same channel and security settings see WLAN Security Settings for details Moreover the same SSID is also needed for clients that roam the APs in Bridge mode The Client automatically scans for any AP that is using the matched SSID and establishes a bridge link with the scanned AP When the AWK 3121 is configured for Client mode it can be used as an Ethernet to wireless or LAN to WLAN network adapter For example a notebook computer equipped with an Ethernet adaptor but no wireless card can be connected to this device with an Ethernet
23. your selection State DREN A Ready To modify the appearance of the PComm Terminal Emulator window select Edit gt Font and then choose the desired formatting options ATTENTION If you unplug the RS 232 cable or trigger DTR a disconnection event will be evoked to enforce logout for network security You will need to log in again to resume operation Configuration by Telnet and SSH Consoles NOTE You may use Telnet or SSH client to access the AWK 3121 and manage the console over a network To access the AWK 3121 s functions over the network from a PC host that is connected to the same LAN as the AWK 3121 you need to make sure that the PC host and the AWK 3121 are on the same logical subnet To do this check your PC host s IP address and subnet mask The AWK 3121 s default I P address is 192 168 127 253 and the default subnet mask is 255 255 255 0 for a Class C network If you do not set these values properly please check the network settings of your PC host and then change the IP address to 192 168 127 xxx and subnet mask to 255 255 255 0 Follow the steps below to access the console utility via Telnet or SSH client 5 3 AirWorks AWK 3121 Other Console Considerations 1 From Windows Desktop run Start gt Run and then use Telnet to access the AWK 3121 s IP address from the Windows Run window you may also issue the telnet command from the MS DOS prompt Run kd d Type the name of a program folder document
24. 2 11b g mode 802 11a mode is not supported Transmission enhancement is also recommended to enable communication at both ends when long distance transmission is required A high gain antenna installed at a fixed antenna connector can also improve performance Select Antenna at MAIN or AUX Antenna Auto The AWK 3121 uses two antennas MAIN and AUX and Auto enables the diversity function for reducing multipath effect MAIN Diversity function is disabled Only MAIN antenna is in use AUX Diversity function is disabled Only AUX antenna is in use 3 19 AirWorks AWK 3121 Web Console Configuration EAPOL Version 1 EAPOL version 1 was standardized in the 2001 version of 1 802 1X which is much more commonly implemented EAPOL version 2 was specified in 802 1X 2004 WMM Enable Disable WMM is a QoS standard for WLAN traffic Voice and video data Disable will be given priority bandwidth when enabled with WMM supported wireless clients Full 11a channel support Enable Disable Full 11a channel support allows users to select one channel Disable from 802 11a including channels in licensed and unlicensed bands READ THIS BEFORE CHANGING THE DFS SETTING DFS Dynamic Frequency Selection is a mechanism to allow unlicensed wireless devices to share spectrum with existing radar systems by detecting radar systems and avoid causing interference with them The current versions of Moxa AWK series products do n
25. 21 you can run a sample test to make sure the AWK 3121 and wireless connection are functioning normally Two testing methods are described below Use the first method if you are using only one AWK 3121 device and use the second method if you are using two or more AWK 3121 units How to Test One AWK 3121 If you are only using one AWK 3121 you will need a second notebook computer equipped with a WLAN card Configure the WLAN card to connect to the AWK 3121 NOTE the default SSID is MOXA and change the IP address of the second notebook Notebook B so that it is on the same subnet as the first notebook Notebook A which is connected to the AWK 3121 After configuring the WLAN card establish a wireless connection with the AWK 3121 and open a DOS window on Notebook B At the prompt type ping lt IP address of notebook A gt and then press Enter see the figure below A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make sure the connections are correct SSID MOXA IP 192 168 127 253 Notebook B Notebook A IP 192 168 127 1 IP 192 168 127 2 2 3 AirWorks AWK 3121 Getting Started How to Test Two or More AWK 3121 Units If you have two or more AWK 3121 units you will need a second notebook computer Notebook B equipped with an Ethernet port Use the default settings for the fir
26. AirWorks AWK 3121 User s Manual Seventh Edition June 2014 www moxa com product MOXA O 2014 Moxa Inc All rights reserved Reproduction without permission is prohibited AirWorks AWK 3121 User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 02014 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these
27. AirWorks AWK 3121 Web Console Configuration Misc Settings Additional settings to help you manage your AWK 3121 are available on this page Misc Settings Reset button Always enable Disable after 60 sec Reset button Always enable The AWK 3121 s Reset button works normally Always enable Disable after 60 sec The AWK 3121 s reset to default function will be inactive 60 seconds after the AWK 3121 finishes booting up Save Configuration The following figure shows how the AWK 3121 stores the setting changes into volatile and non volatile memory All data stored in volatile memory will disappear when the AWK 3121 is shutdown or rebooted unless they are y Because the AWK 3121 starts up and initializes with the settings stored in flash memory all new changes must be saved to flash memory before restarting the AWK 3121 This also means the new changes will not work unless you run either the Save Configuration function or the Restart function Configuration E setting changes Restart without saving configuration volatile non volatile The system reboots and memory _ memory _ Restart initialize with the settings in falsh memory Save and Restart After you click on Save Configuration in the left menu box the following screen will appear Click Save if you wish to update the configuration settings in the flash memory at this time Alternatively you may choose to run other functions and put o
28. BC 01 Import Contig Import ABC 01 Export Config Export To download the configuration to the AWK Turn off the AWK Plug in the ABC 01 to the AWK s RS 232 console Turn on AWK AWK will detect ABC 01 during bootup and download the configuration from the ABC 01 to the AWK automatically Once the configuration downloads and if configuration format is correct the AWK will emit oY three short beeps then continue the boot up 5 Once the AWK has booted up successfully it will emit the normal two beeps and the ready LED will turn to solid green Factory Default Use this function to reset the AWK 3121 and roll all settings back to the factory default values You can also reset the hardware by pressing the reset button on the top panel of the AWK 3121 Load Factory Default Reset to Factory Default Click Activate to reset all settings including the console password to the factory default values The system will be restarted immediately Activate Password You can change the administration password for each of the AWK 3121 s console managers by using the Password function Before you set up a new password you must input the current password and reenter the new password for confirmation For your security do not use the default password root and remember to change the administration password regularly Password Current password e Mew password Jeescene Confirm password fessesso 3 41
29. Certificate reduction makes TTLS and PEAP much more popular than EAP TLS The AWK 3121 provides some non cryptographic EAP methods including PAP CHAP MS CHAP and MS CHAP V2 These EAP methods are not recommended for direct use on wireless networks However they may be useful as inner authentication methods with TTLS and PEAP Because the inner and outer authentications can use distinct user names in TTLS and PEAP you can use an anonymous user name for the outer authentication with the true user name only shown through the encrypted channel Keep in mind that not all client software supports anonymous alteration Confirm this with the network administrator before you enable identity hiding in TTLS and PEAP WLAN Security Settings Security mode WPAZ WPA type Enterprise Encryption method TKIP EAP Protocol TLS TTLS Inner Authentication MS CHAP V2 Anonymous User name Password TTL Inner Authentication Password Authentication Protocol is used MS CHAP V2 CHAP Challenge Handshake Authentication Protocol is used MS CHAP Microsoft CHAP is used MS CHAP V2 Microsoft CHAP version 2 is used Anonymous Factory Default Max of 31 characters A distinct name used for outer authentication None User name amp Password Factory Default User name and password used in inner authentication None 3 16 AirWorks AWK 3121 PEAP Web Console Configuration There are a few differences in the TTLS and PEAP i
30. K 3121 s current status The information is categorized into several groups System info Device info and 802 11 info Overview All information on this page are active values System Info Model name AWK 3121 U5 Device name AWK 3121 954 Serial No 9547 System up time 3 days 14h 01m 05s Firmware version 1 10 Build 13082217 Device Info Device MAC address 00 90 E8 245 05 CB IP address 192 168 127 253 Subnet mask 255 255 255 0 Gateway 802 11 Info Country code Operation mode AP Channel 6 RF type B G Mixed SSID AirWorks AWK 3121 Web Console Configuration Click on SSID for more detailed 802 11 information as shown in the following figure Wireless Status Auto refresh Show status of 807 11 info Operation mode Client Channel Mot connected RF type Br Mixed SSID MOA Security mode OFEN Current BSSID HA Signal strength olll 06 dem Transmission rate Py fs Transmission power Full NOTE The 802 11 info that is displayed may be different for different operation modes For example Current BSSID is not available in Client mode and Signal strength is not available in AP mode Basic Settings The Basic Settings group includes the most commonly used settings required by administrators to maintain and control the AWK 3121 System Info Settings The System Info items especially Device name and Device description are displayed and included on the Overview page in SNMP information and
31. Query period 500 600 9999 seconds The Current local time shows the AWK 3121 s system time when you open this web page You can click on the Set Time button to activate the updated date and time parameters An Updated string will appear to indicate that the change is complete Local time settings will be immediately activated in the system without running Save and Restart NOTE The AWK 3121 has a built in real time clock RTC We strongly recommend that users update the Local time for the AWK 3121 after the initial setup or a long term shutdown especially when the network does not have an Internet connection for accessing the NTP server or there is no NTP server on the LAN Current local time User adjustable time The date and time parameters allow configuration of the local time with immediate activation Use 24 hour format yyyy mm dd hh mm ss Time zone User selectable time The time zone setting allows conversion from GMT Greenwich GMT Greenwich zone Mean Time to local time Mean Time ATTENTION Changing the time zone will automatically adjust the Current local time You should configure the Time zone before setting the Current local time Daylight saving time Enable Disable Daylight saving time also know as DST or summer time Disable involves advancing clocks usually 1 hour during the summer time to provide an extra hour of daylight in the afternoon 3 6 AirWorks AWK 3121 Web Consol
32. S Transmission Rates 802 11b 1 2 5 5 11 Mbps 802 1la g 6 9 12 18 24 36 48 54 Mbps TX Transmit Power for hardware revision 1 2 802 11b Typ 23 1 5 dBm 1 to 11 Mbps 802 119 Typ 20 1 5 dBm 6 to 24 Mbps Typ 19 1 5 dBm 36 Mbps Typ 18 1 5 dBm 48 Mbps Typ 171 5 dBm 54 Mbps 802 11a Typ 18 1 5 dBm 6 to 24 Mbps Typ 16 1 5 dBm 36 to 48 Mbps Typ 15 1 5 dBm 54 Mbps RX Sensitivity for hardware revision 1 2 802 11b 97 dBm 1 Mbps 94 dBm 2 Mbps 92 dBm 5 5 Mbps 90 dBm 11 Mbps 802 119 93 dBm 6 Mbps 91 dBm 9 Mbps 90 dBm 12 Mbps 88 dBm 18 Mbps 84 dBm 24 Mbps 80 dBm 36 Mbps 76 dBm 48 Mbps 74 dBm 54 Mbps 802 11a 90 dBm 6 Mbps 89 dBm 9 Mbps 89 dBm 12 Mbps 85 dBm 18 Mbps 83 dBm 24 Mbps 79 dBm 36 Mbps 75 dBm 48 Mbps 74 dBm 54 Mbps 1 3 AirWorks AWK 3121 Introduction TX Transmit Power for hardware revisions 1 0 and 1 1 802 11b Typ 18 1 5 dBm 1 to 11 Mbps 802 119 Typ 18 1 5 dBm 6 to 24 Mbps Typ 16 1 5 dBm 36 to 48 Mbps Typ 15 1 5 dBm 54 Mbps 802 11a Typ 16 1 5 dBm E 6 to 24 Mbps Typ 14 1 5 dBm 36 to 48 Mbps Typ 1341 5 dBm 54 Mbps RX Sensitivity for hardware revisions 1 0 and 1 1 802 11b 92 dBm 1 Mbps 90 dBm 2 Mbps 88 dBm 5 5 Mbps 84 dBm 11 Mbps 802 119 87 dBm 6 Mbps 86 dBm 9 Mbps 85 dBm 12 Mbps 82 dBm 18 Mbps 80 dBm 24 Mbps 76 dBm 36 Mbps
33. SET button down for under 5 seconds and then release e Reset to factory default Hold the RESET button down for over 5 seconds until the STATE LED starts blinking green Release the button to reset the AWK 3121 RESET button Relay Digital Output The AWK 3121 has one relay output consisting of the 2 terminal block contacts on the top panel as shown below These relay contacts are used to forward system failures and user configured events The two wires attached to the relay contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the relay circuit will remain closed For safety reasons the relay circuit is kept open when the AWK 3121 is not powered up Summary of the AWK 3121 s Relay Status Power Status Event Relay AC RC es open LJ L LJ Lj 1 7 2 Getting Started This chapter explains how to install Moxa s AirWorks AWK 3121 for the first time and quickly set up your wireless network and test whether the connection is running well The function guide provides a convenient means of determining which functions you need to use The following topics are covered in this chapter O First time Installation and Configuration O Communication Testing O Function Map AirWorks AWK 3121 Getting Started First time Installation and Configuration Before installing the AWK 3121 make sure that all items in the Package Checklist are in the box You wi
34. Syslog Server Syslog port Port destination Enter the UDP port of the corresponding Syslog server 514 1 to 65535 3 33 AirWorks AWK 3121 E mail E mail Event Types Web Console Configuration Check the box for Active to enable the event items All default values are deactivated unchecked Details for each event item can be found on the System log Event Types table on page 3 31 E mail Event Types Event Cold start Warm start PoE transition On gt 0ff PoE transition Off gt On Configuration changed Console authentication failure DI 1 transition On gt Off DI 1 transition Off gt On DI 2 transition On gt Off DI 2 transition Off gt On LAN link on LAN link off Power 1 transition On gt Off Power 1 transition Off gt On Power 2 transition On gt Off Power 2 transition Off gt On b P z lt m m N N fig ff MAL Mid N E mail Server Settings You can set up to 4 e mail addresses to receive alarm emails from the AWK 3121 The following parameters can be configured on the E mail Server Settings page In addition a Send Test Mail button can be used to test whether the Mail server and e mail addresses work well More detailed explanations about these parameters are given after the following figure E mail Server Settings Mail server SMTP User name Password From e mail address To e mail address 1 To e mail address 2 To e mail
35. The AWK 3121 is disassociated from an AP for Client Slave mode Configuration file import via Web Console Console authentication failure Power 1 2 transition On gt Off Power 1 2 transition Off gt On 3 32 AirWorks AWK 3121 Web Console Configuration DI 1 2 transition On gt Off Digital Input 1 2 is triggered by on to off transition DI 1 2 transition Off gt On Digital Input 1 2 is triggered by off to on transition Syslog This function provides the event logs for the Syslog server The function supports up to three configurable Syslog servers and Syslog server UDP port numbers When an event occurs the event will be sent as a Syslog UDP packet to the specified Syslog servers Syslog Event Types Detail information for the grouped events is shown in the following table You can check the box for Enable log to enable the grouped events All default values are enabled checked Details for each event group can be found on the System log Event Types table on page 3 31 Syslog Event Types Event group Enable log System related events MNetwork related events Config related events Power events DI events Syslog Server Settings You can configure the parameters for your Syslog servers in this page Syslog Server Settings Syslog server 1 Syslog port Syslog server 2 Syslog port Syslog server 3 Syslog port Syslog server 1 2 3 IP address Enter the IP address of the 1st 2nd 3rd
36. Traffic Indicator Message TIM Beacon Interval indicates the frequency interval of AP DTI M Delivery Traffic Indication Map DTI M is contained in beacon frames It is used to indicate that broadcast and multicast frames buffered by the AP will be delivered shortly Lower settings result in more efficient networking while preventing your PC from dropping into power saving sleep mode Higher settings allow your PC to enter sleep mode thus saving power Fragment A lower setting means smaller packets which will create more packets for each transmission If you have decreased this value and experience high packet error rates you can increase it again but it will likely decrease overall network performance Only minor modifications of this value are recommended RTS Threshold RTS Threshold 256 2346 This setting determines how large a packet can be before the Access Point coordinates transmission and reception to ensure efficient communication This value should remain at its default setting of 2 346 When you encounter inconsistent data flow only minor modifications are recommended AirWorks AWK 3121 References STP and RSTP The STP RSTP Concept Spanning Tree Protocol STP was designed to help reduce link failures in a network and provide protection from loops Networks that have a complicated architecture are prone to broadcast storms caused by unintended loops in the network The STP protocol is part of the I EEE802 1D stan
37. address 3 To e mail address 4 Submit Send Test Mail Mail server SMTP ss c IP address The IP Address of your email server 3 34 AirWorks AWK 3121 Web Console Configuration User name amp Password A User name and password used in the SMTP server From e mail address Max 63 characters Enter the administrator s e mail address which will be shown in None the From field of a warning e mail To E mail address 1 2 3 4 Max 63 characters Enter the receivers e mail addresses Relay Trap The AWK 3121 has one relay output which consists of 2 terminal block contacts on the AWK 3121 s top panel These relay contacts are used to indicate user configured events and system failure The two wires attached to the relay contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the relay circuit will remain closed For safety reasons the relay circuit is kept open when the AWK 3121 is not powered Relay Event Types You can check the box for Active to enable the event items All default values are deactivated unchecked Details for each event item can be found in the System log Event Types table on page 3 31 Relay Event Types Event Power 1 transition On gt Off Power 2 transition On gt Off PoE transition On gt 0ff DI 1 transition On gt Off DI 1 transition Off gt On DI 2 transition On gt Off DI 2 t
38. address Device MAC address Firmware versio Ey 1 AME 3121 115 132 168 127 253 O00 90 98 00 00 01 255 255 255 0 1 2 Build 09052 System info Device info 202 11 info FL Exit Model name Aw E 3121 U5 Locate SAR Device name AWK 3121_9390 Serial Ho 9390 Locating System up time 0 dave OD0h D0m 51 2 Model AMWE 3121 U5 Firmware version 1 2 Build 09052501 IF 192 168 127 253 00 90 E8 00 00 01 Metmazk 255 255 255 0 5 Make sure your AWK is unlocked before using the search utility s icons setting The AWK will unlock automatically if the password is set to the default Otherwise you must enter the new password manually 6 Goto Tools gt AWK login Options to manage and unlock additional AWKs AWE Search Utility File Edit Function Tools Help ro E Utility Login Options a IP a 7 Search Search AMET Telnet Assign IP Upgrade Refresh Refresh All Model name Advanced Options evice MAC address Firmware versio AWK 31214 Customize List View ETM SSSA n 0 255 255 255 0 EME system info Device info 802 11 info FL Exit Model name AMWE 3121 U5 Device name AMWE 3121_ 9390 Serial No 33590 System up time 0 days 00h 00m 57 Firmware version 1 2 Build 09052507 7 Use the scroll down list to select the MAC addresses of those AWKs you would like to manage and then click Add Key in the password for the AWK device and then click OK to save If you return to the search page and search for the AWK
39. again you will find that the AWK will unlock automatically ATTENTION For security purposes we suggest you can change the AWK search utility login password instead of using the default AWE Login Options Found awe devicelsl 499 166 127 253 00 90 8 00 40 01 a Add Last IP Device MAC address Username COM NAAA cE 192 168 127 253 00 90 9 00 40 01 admin AirWorks AWK 3121 Software Installation and Configuration To modify the configuration of the highlighted AWK click on the Web icon to open the web console This will take you to the web console where you can make all configuration changes Refer to Chapter 3 Using the Web Console for information on how to use the web console e AWK Search Utility Sele File Edit Function Tools Help 2 Xx a Hs Y E ni F Search Search Ex Ae wi ibe Assign IP Unlock Upgrade Refresh Refresh ll Exit No Modelmame IFP address Device MAC address Subnet mask Firmware versio a AWK 3121 U5 192 168 127 253 00 90 E8 00 00 01 255 255 255 0 IEEE System info Device info 802 11 into Model name AWE 3721 U5 Device name AWE 3721_ 9390 Serial No 3390 System up time O days 00h 00m 51s Firmware version 1 2 Build 09052501 Click on Telnet if you would like to use telnet to configure your AWKs AWE Search Utility File Edit Function Tools Help a Ek el nM FL Search Search Ex Locate Wi coal IP Unlock Upgrade Refresh
40. are out of the control room for an extended period they can still be informed of the status of devices almost instantaneously when exceptions occur In addition to logging these events the AWK 3121 supports different approaches to warn engineers automatically such as SNMP trap e mail and relay output It also supports two digital inputs to integrate sensors into your system to automate alarms by email and relay output System Log System Log Event Types Detail information for grouped events is shown in the following table You can check the box for Enable log to enable the grouped events All default values are enabled checked The log for system events can be seen in Status gt System Log System log Event Types Event group Enable log x System related events Metwork related events Config related events Power events a A A DI events System related events Event is triggered when System restart warm start The AWK 3121 is rebooted such as when its settings are changed IP address subnet mask etc Network related events Event is triggered when LAN link on The LAN port is connected to a device or network LAN link off The port is disconnected e g the cable is pulled out or the opposing device shuts down Client joined left A wireless client is associated or disassociated for AP Master mode WLAN connected to AP The AWK 3121 is associated with an AP for Client Slave mode WLAN disconnected
41. armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help B 2 AirWorks AWK 3121 Supporting I nformation NOTE FCC Caution To assure continued compliance example use only shielded interface cables when connecting to computer or peripheral devices Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operated in conjunction with any other antenna or transmitter FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment sho
42. articular AWK 3121 You can click Select all to select all the content in the list for further editing You can click Refresh to refresh the list Associated Client List 1 lt 00 13 ce el ee ef gt Select all Refresh DHCP Client List for AP mode only The DHCP Client List shows all the clients that require and have successfully received IP assignments You can click the Refresh button to refresh the list DHCP Client List MAC IP 00 13 c0e el ee ef 192 168 12 2 Select all Refresh You can press Select all button to select all content in the list for further editing 3 37 AirWorks AWK 3121 Web Console Configuration Select All Print Select all Refresh System Log Triggered events are recorded in System Log You can export the log contents to an available viewer by clicking Export Log You can use the Clear Log button to clear the log contents and the Refresh button to refresh the log System Log 116 2008 06 18 20h 46m 50s Power 1 transition Of gt On 117 2008 06 18 20h 46m 50s LAN link on 118 2008 06 18 21h 1 m 01s System restart 119 2008 06 18 21h 1 m 10s Power 1 transition Of gt On 120 2008 06 18 21h 1 m 10s LAN link on 121 2008 06 18 21h 19m 55s System restart 122 2008 06 18 21h 20m 04s Power 1 transition Of gt On 123 2008 06 18 21h 20m 04s LAN link on 124 2008 06 18 21h 20m ei1s Client 00 13 CE E1 EE EF joined 125 2008 06 18 21h
43. cable to provide wireless connectivity to another AP Although it is more convenient to use dynamic bridging there is a limitation the Client can only transmit IP based packets between its wireless interface WLAN and Ethernet interface LAN other types of traffic such as IPX and AppleTalk are not forwarded 3 7 AirWorks AWK 3121 Web Console Configuration Operation Mode The AWK 3121 supports four main operation modes Client AP Master and Slave each of which plays a distinct role on the wireless network Operation Mode Wireless enable Enable Disable Operation mode Wireless Enable Setting Description Factory Default Enable Disable The RF Radio Frequency module can be manually turned on or Enable off This function is available in AP operation mode only OS Operation Mode AP Y Master This mode collocates with AWK 5222 5232 6222 6232 s Wireless bridge mode The AWK 3121 plays the role of wireless Master Slave This mode collocates with AWK 5222 5232 6222 6232 s MS Wireless bridge mode The AWK 3121 plays the role of wireless Slave Basic Wireless Settings The WLAN Basic Setting Selection panel is used to add and edit SSIDs An SSID is a unique identifier that wireless networking devices use to establish and maintain wireless connectivity Multiple access points on a network or sub network can use the same SSIDs You can configure your AWK to use up to 9 SSIDs and configure each SSID
44. changes are incorporated into new editions of the publication Technical Support Contact I nformation www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 Table of Contents De a e UT O al o y PEPPER rro O 1 1 OVINOS 1 2 Package C NECkiS E aiian a a a aaa aa ee td 1 2 Product FOUR E ESENE A AN a S KIE a NN 1 2 Product Ss OSC IE CEOS ees coros 1 3 Funcional DESIG cartier aaa ee el ed eae A AA A 1 5 ED dG Gan Ol Stet giet als tehet abs ela veh sete tet ee venues aed vas das aes ee aang rane nana yonene E 1 5 O 1 6 Ro ee OS 1 7 READ cia 1 7 A alo o OO OOOO 2 1 First time Installation and Configuration iii ici ii 2 2 COMUNICACION TES too lia AAN 2 3 FUNCION Mapoteca ee denon TUET 2 5 Ja Web Console Contigua lO Nasa aaa cacon andnancn on cacndocadennas 3 1 Web Browser COMPOQURAUO Ns sisaria A AREARE 3 2 SN at A A A AUN ASA ANAS AAAS ea E A E AS 3 3 Basic SetunOsS strict re eer ee cee DAE SA OA AE te nr re ne nr 3 4 System Into S SUMING Seg oa seo ee eo 3 4 Nr A A TE 3 5 TME SEMOS supina ee ee Te re ere te cs 3 6 MVP ST SSS QUIN GS acia 3 7 Operation MOS aii a atea ando 3 8 AS SeMS eira aa a eases ae aes saa cae sas ee a ao eo 3 8 WEAN SSC LIA S
45. dard 1998 Edition bridge specification Rapid Spanning Tree Protocol RSTP implements the Spanning Tree Algorithm and Protocol defined by EEE802 1w 2001 standard RSTP provides the following benefits e The topology of a bridged network will be determined much more quickly compared to STP e RSTP is backward compatible with STP making it relatively easy to deploy For example gt Defaults to sending 802 1D style BPDUs if packets with this format are received gt STP 802 1D and RSTP 802 1w can operate on the LAN ports and WLAN ports AP and WDS1 WDS8 of the same AWK 3121 This feature is particularly helpful when the AWK 3121 connects to older equipment such as legacy switches Differences between RSTP and STP RSTP is similar to STP but includes additional information in the BPDUs that allow each bridge to confirm that it has taken action to prevent loops from forming when it decides to enable a link to a neighboring bridge Adjacent bridges connected via point to point links will be able to enable a link without waiting to ensure that all other bridges in the network have had time to react to the change The main benefit of RSTP is that the configuration decision is made locally rather than network wide allowing RSTP to carry out automatic configuration and restore a link faster than STP Supporting Information This chapter presents additional information about this manual and product You can also learn how to contact Moxa f
46. ddress Identifies the AWK 3121 on a TCP IP network 192 168 127 253 Subnet mask AWK 3121 s subnet Identifies the type of network to which the AWK 3121 is 255 255 255 0 mask connected e g 255 255 0 0 for a Class B network or 255 255 255 0 for a Class C network Gateway AWK 3121 s default The IP address of the router that connects the LAN to an outside None gateway network Primary Secondary DNS server IP address of the The IP address of the DNS Server used by your network After None Primary Secondary entering the DNS Server s IP address you can input the DNS server AWK 3121 s URL e g http ap11 abc com in your browser s address field instead of entering the IP address The Secondary DNS server will be used if the Primary DNS server fails to connect 3 5 AirWorks AWK 3121 Web Console Configuration Time Settings The AWK 3121 has a time calibration function based on information from an NTP server or user specified Date and Time information Functions such as Auto warning can add real time information to the message Time Settings Date YYYY MM DD Time HH MM SS Current local time 2009 H o1 H 23 is 58 is Set Time Time zone GMT 06 00 Central Time US amp Canada Daylight saving time Enable Starts at Apr y ist y sun y oo foo HH MM Stops at oct y llast y sun y foo foo HH MM Time offset 01 00 Time server 1 ltime nist gow Time server 2
47. ded web browser is Microsoft Internet Explorer 7 0 or 8 0 with JVM Java Virtual Machine installed To use the AWK 3121 s management and monitoring functions from a PC host connected to the same LAN as the AWK 3121 you must make sure that the PC host and the AWK 3121 are on the same logical subnet Similarly if the AWK 3121 is configured for other VLAN settings you must make sure your PC host is on the management VLAN The Moxa AWK 3121 s default IP is 192 168 127 253 Follow these steps to access the AWK 3121 s web based console management interface Press Enter to establish the connection 3 about blank Microsoft Internet Explorer Oj xj File Edit View Favorites Tools Help m O Back ir y x 2 A jJ Search Se Favorites En eb pS 2 The Web Console Login page will open Enter the password default Username admin default Password root and then click Login to continue Web Console Login Username admin Password Login goahead WEBSERVER 3 You may need to wait a few moments for the web page to download to your computer Note that the Model name and IP address of your AWK 312 are both shown in the title bar of the web page This information can be used to help you identify multiple AWK 3121 units 3 2 Web Console Configuration Internet Explorer and type the AWK 3121 s IP address in the address field AirWorks AWK 3121 Web Console Configuration 4 Use the menu tree on
48. derations RS 232 Console Configuration 115200 None 8 1 VT100 The serial console connection method which requires using a short serial cable to connect the AWK 3121 to a PC s COM port can be used if you do not know the AWK 3121 s IP address It is also convenient to use serial console configurations when you cannot access the AWK 3121 over Ethernet LAN such as in the case of LAN cable disconnections or broadcast storming over the LAN ATTENTION Do not use the RS 232 console manager when the AWK 3121 is powered at reversed voltage ex 48VDC even though reverse voltage protection is supported If you need to connect the RS 232 console at reversed voltage Moxa s TCC 82 isolator is your best solution NOTE We recommend using Moxa PComm Lite Terminal Emulator which can be downloaded free of charge from Moxa s website Before running PComm Terminal Emulator use an RJ45 to DB9 F or RJ45 to DB25 F cable to connect the AWK 3121 s RS 232 console port to your PC s COM port generally COM1 or COM2 depending on how your system is set up After installing PComm Terminal Emulator take the following steps to access the RS 232 console utility 1 From the Windows desktop open the Start menu and start PComm Terminal Emulator in the PComm Lite group 2 Select Open under Port Manager to open a new connection En PComm Terminal Emulator Mim E4 Profile a 3 The Communication Parameter page of the Property window ope
49. differently All of the SSIDs are active at the same time that is client devices can use any of the SSIDs to associate with the access point WLAN Basic Setting Selection Status SSID Operation Mode Action Active MOXA AP Add SSID Click on Add SSID to create more SSI Ds Status Operation Mode Action Active AP Edit Inactive AP Save Cancel Add SSID 3 8 AirWorks AWK 3121 Web Console Configuration NOTE NOTE Click on Edit to assign different configuration settings to each SSID The configuration panel appears as follows Basic Wireless Settings Operation mode Client RF type Channel SSID broadcast Enable Disable WDS Enable Disable When you switch to Client mode a Site Survey button will be available on the Basic Wireless Settings panel Click the Site Survey button to view information about available APs as shown in the following figure You can click on the SSID of an entity and bring the value of its SSID onto the SSID field of the Basic Wireless Settings page Click the Refresh button to re scan and update the table Basic Wireless Settings Operation mode Client RF type B G Mixed Channel SSID MOXA site Survey SSID broadcast Enable Disable WDS Enable Disable http 192 168 127 253 Site Survey Microsoft Internet Explorer Site Survey Mo SSID MAC address Channel Mode Signal 1 Home 00 18 84 81 CD 9A 1 BSS WEP 2000 2 FON_AP 00 18 84
50. ds or EAP protocols EAP TLS EAP TTLS and EAP PEAP corresponding to WPA WPA Enterprise settings on the AP side WLAN Security Settings Security mode DE WPA type Enterprise Encryption method EAP Protocol Encryption method TKIP Temporal Key Integrity Protocol is enabled TKIP AES Advance Encryption System is enabled EAP Protocol TLS Specifies Transport Layer Security protocol TLS TTLS Specifies Tunneled Transport Layer Security PEAP Specifies Protected Extensible Authentication Protocol or Protected EAP Before choosing the EAP protocol for your WPA WPA2 Enterpise settings on the client end please contact the network administrator to make sure the system supports the protocol on the AP end Detailed information on these three popular EAP protocols is presented in the following sections EAP TLS TLS is the standards based successor to Secure Socket Layer SSL It can establish a trusted communication channel over a distrusted network TLS provides mutual authentication through certificate exchange EAP TLS is also secure to use You are required to submit a digital certificate to the authentication server for validation but the authentication server must also supply a certificate You can use Basic Wireless Settings gt WLAN Certificate Settings to import your WLAN certificate and enable EAP TLS on the client end WLAN Security Settings Security mode DE WPA type Enterprise Encryption meth
51. e AWK 3121 can operate at temperatures ranging from 25 to 60 C for standard models and 40 to 75 C for extended temperature models and is rugged enough for any harsh industrial environment Installation is easy with either DI N Rail mounting or wall mounting in distribution boxes The DIN Rail wall mounting capability wide operating temperature range and IP30 housing with LED indicators make the AWK 3121 a convenient yet reliable solution for any industrial wireless application Package Checklist Moxa s AWK 3121 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance e 1 AWK 3121 e 2 Dual band Omnidirectional Antennas 2dBi RP SMA 2 48 amp 5GHz e 1 Quick Installation Guide e 1 Software CD e 1 Moxa Product Warranty Card e 1 Cable holder with 1 screw e 2 Protective caps NOTE The above items come with the standard AWK 3121 model but the package contents may vary for customized versions Product Features e EEE802 11a b g compliant e Three in one design AP Bridge Client e Advanced wireless security gt 64 bit and 128 bit WEP WPA WPA2 gt SSID Hiding IEEE 802 1X RADIUS gt Packet access control amp filtering e STP RSTP support for network system redundancy for Master and Slave mode only e Long distance transmission support e Turbo Roaming enables rapid handover for Client mode only e ABC O1 for configuration
52. e AWK Search Utility program When the Login page appears select the Search AWK only option to search for AWKs and to view each AWK s configuration Select the AWK management option to assign IPs upgrade firmware and locate devices AWE Search Utility Login AWK Search Utility f AWE management af OK aC Cancel 2 Open the AWK Search Utility and then click the Search icon AWE Search Utility File Edit Function Tools Help SearchEx 7 IP address _ Device MAC address 3 The Searching window indicates the progress of the search When the search is complete all AWKs that were located will be displayed in the AWK Search Utility window 0 AWK Search Utility Ea px File Edit Function Tools Help lt if EG E d E m Search SearchEx 7 Locate Ww Telnet Assign IP Upgrade Retesh Refresh All IP address Device MAC address Firmware versio AMWE 3121 US 00 90 68 00 00 01 255 255 255 0 eee System info Device into 802 11 info F Exit Model name AA 2121 05 Device name AMWE 3121_ 9390 Serial No 9390 System up time O days O0h 00rn 51s Firmware wersion 1 2 Build 09052501 AirWorks AWK 3121 Software Installation and Configuration 4 Click Locate to cause the selected device to beep 2 AWE Search Utility File Edit Function Tools Help ra re Bg a E Y E nu rare es lt El gt i Search Search Ex Locate Wi Telnet Assign IP Upgrade Refresh Refresh All IP
53. e Configuration When Daylight saving time is enabled the following parameters will be shown e Starts at The date that daylight saving time begins e Stops at The date that daylight saving time ends e Time offset Indicates how many hours forward the clock should be advanced Time server 1 2 IP Name of Time IP or Domain name of the NTP time server The 2nd NTP server Time nist gov Server 1 2 will be used if the 1st NTP server fails to connect Query period Query period time This parameter determines how often the time is updated from 600 seconds 1 to 9999 seconds the NTP server Wireless Settings NOTE The essential settings for wireless networks are presented in this function group Settings must be properly set before establishing your wireless network Familiarize yourself with the following terms before starting the configuration process AP Bridge This mode provides both Access Point and Static LAN to LAN Bridging functionality The static LAN to LAN bridging function is supported by the Wireless Distribution System WDS Client This mode is for Dynamic LAN to LAN Bridging or Device to LAN scenarios The Client automatically establishes bridge links with other APs In either AP Bridge or Client mode the AWK 3121 forwards packets between its Ethernet interface LAN and wireless interface WLAN to connect wired hosts on the Ethernet side with wireless host s on the wireless side There are two types of
54. enable data encryption to enhance data security The AWK 3121 s MIB can be found in the software CD and supports reading the attributes via SNMP Only get method is supported SNMP security modes and security levels supported by the AWK 3121 are shown in the following table Select the security mode and level that will be used to communicate between the SNMP agent and manager 3 29 AirWorks AWK 3121 Web Console Configuration Protocol Setting on Authentication Data Version UI web page Type Encryption SNMP V1 V2c Community Use a community string match for V1 V2c Read string authentication Community V1 V2c Community Use a community string match for Write Read string authentication Community SNMP V3 No Auth Use account with admin or user to access objects MD5 or SHA Authentication Provides authentication based on based on MD5 or HMAC MD5 or HMAC SHA algorithms SHA 8 character passwords are the minimum requirement for authentication MD5 or SHA Authentication Provides authentication based on HMAC MD5 based on MD5 or encryption or HMAC SHA algorithms and data SHA encryption key 8 character passwords anda data encryption key are the minimum requirements for authentication and encryption The following parameters can be configured on the SNMP Agent page A more detailed explanation of each parameter is given below the following figure SNMP Agent Enable Disable Remote management Disable Read community publ
55. er Settings vi ist Trap version ist Trap server IP name viele ist Trap community laet 2nd Trap version Kiz 2nd Trap server IP name 2nd Trap community laet lst 2nd Trap version SNMP trap defined in SNMPv1 V1 SNMP trap defined in SNMPv2 lst 2nd Trap server P name IP address or host Enter the IP address or name of the trap server used by your None name network 1st 2nd Trap community Max of 31 characters Use a community string match with a maximum of 31 alert characters for authentication 3 36 AirWorks AWK 3121 Web Console Configuration Status Wireless Status The status for 802 11 info parameters such as Operation mode and Channel are shown on the Wireless Status page The status will refresh every 5 seconds if the Auto refresh box is checked Certain values for 802 11 info may not show up due to different operation modes As a result Current BSSID and Signal strength are not available in AP mode It is helpful to use the continuously updated information on this page such as Signal strength to monitor the signal strength of the AWK 3121 in Client mode Wireless Status Auto refresh 807 11 info Operation mode AP Channel 6 RF type Br Mixed Current BSSID est Signal strength HA Transmission rate Auto Transmission power Full Associated Client List for AP mode only Associated Client List shows all the clients that are currently associated to a p
56. erver and easily assign IP addresses to your DHCP clients by responding to the DHCP requests from the client ends The P related parameters you set on this page will also be sent to the client You can also assign a static P address to a specific client by entering its MAC address The AWK 3121 provides a Static DHCP mapping list with up to 16 entities Be reminded to check the Active check box for each entity to activate the setting You can check the IP assignment status under Status gt DHCP Client List DHCP Server AP only DHCP server Default gateway Subnet mask Primary DNS server Secondary ONS server Start IP address Maximum number of users Client lease time 1 10 days Static DHCP mapping lactive IP Address MAC Address Factory Default Enables AWK 3121 as a DHCP server Disable Disable DHCP server function Default gateway Factory Default IP address of a default The IP address of the router that connects to an outside None gateway network Subnet mask Setting Description Factory Default subnet mask Identifies the type of sub network e g 255 255 0 0 for a None Class B network or 255 255 255 0 for a Class C network Primary Secondary DNS server IP address of Primary The IP address of the DNS Server used by your network After None Secondary DNS server entering the DNS Server s IP address you can use URL as well The Secondary DNS server will be used if the Primary DNS s
57. erver fails to connect 3 24 AirWorks AWK 3121 Web Console Configuration Start I P address IP address Indicates the IP address which AWK 3121 can start assigning Maximum number of users 1 999 Specifies how many IP address can be assigned continuously Client lease time 1 10 days The lease time for which an IP address is assigned The IP 10 days address may go expired after the lease time is reached Packet Filters The AWK 3121 includes various filters for I P based packets going through LAN and WLAN interfaces You can set these filters as a firewall to help enhance network security MAC Filter The AWK 3121 s MAC filter is a policy based filter that can allow or filter out IP based packets with specified MAC addresses The AWK 3121 provides 8 entities for setting MAC addresses in your filtering policy Remember to check the Active check box for each entity to activate the setting MAC Filters Enable Disable Policy Drop No active Name MAC address Enable Enables MAC filter Disable Policy Only the packets fitting the entities on list can be allowed Drop Any packet fitting the entities on list will be denied ATTENTION Be careful when you enable the filter function Drop no entity on list is activated all packets are allowed Accept no entity on list is activated all packets are denied 3 25 AirWorks AWK 3121 Web Console Configuration IP Protocol F
58. fault Login Locate Assign IP Upload Firmware and Unlock to complete Upgrade timeout secs Use this option to set the waiting time for the connection to disconnect while the firmware is upgrading Use this option to set the waiting time for the Firmware to write to flash Advanced Options Search Connection Misc Connection timeout secs 0 Upgrade timeout zeca 500 fr OF E Cancel Misc Search on start Checkmark this box if you would like the search function to start searching for devices after you log in to the AWK search Utility Advanced Options Search Connection Misc Search on start ff OF XK Cancel 5 Other Console Considerations This chapter explains how to access the AWK 3121 for the first time In addition to HTTP access there are four ways to access AWK 3121 serial console Telnet console SSH console and HTTPS console The serial console connection method which requires using a short serial cable to connect the AWK 3121 to a PC s COM port can be used if you do not know the AWK 3121 s IP address The other consoles can be used to access the AWK 3121 over an Ethernet LAN or over the Internet The following topics are covered in this chapter O RS 232 Console Configuration 115200 None 8 1 VT100 O Configuration by Telnet and SSH Consoles O Configuration by Web Browser with HTTPS SSL O Disabling Telnet and Browser Access AirWorks AWK 3121 Other Console Consi
59. ff saving the configuration until later However the new setting changes will remain in the non volatile memory until you save the configurations Save Configuration If you have submitted any configuration changes you must save the changes and restart the server before they take effect Click Save to save the changes in the AWK 3121 US s memory Click Restart to activae new settings in the navigation panel Save 3 42 AirWorks AWK 3121 Web Console Configuration Restart If you submitted configuration changes you will find a blinking string in the upper right corner of the screen After making all your changes click the Restart function in the left menu box One of two different screens will appear If you made changes recently but did not save you will be given two options Clicking the Restart button here will reboot the AWK 3121 directly and all setting changes will be ignored Clicking the Save and Restart button will apply all setting changes and then reboot the AWK 3121 Restart IH Warning Click Restart to discard changes and reboot the AWK 3121 US directly Click Save and Restart to apply all setting changes and reboot the AWK 3121 US Restart Save and Restart If you run the Restart function without changing any configurations or saving all your changes you will see just one Restart button on your screen Restart IH Warning Clicking Restart will disconnect all Ethernet connections and
60. groups In a typical scenario each user VLAN represents a department workgroup for example one VLAN could be used for a marketing department and the other for a human resource department In this scenario the AP would assign every packet it accepted to a VLAN Each packet would then be identified as marketing or human resource depending on which wireless client received it The AP would insert VLAN headers or tags with identifiers into the packets transmitted on the wired backbone to a network switch Finally the switch would be configured to route yLAN 3 packets from the marketing department to the vAN floor 3 appropriate corporate resources such as printers Ln TL 503 and servers Packets from the human resource X ib a poor A ggi0 1 E poor department could be restricted to a gateway that a allowed access to only the Internet A member of sei E the human resource department could send and X receive e mail and access the Internet but would A G be prevented from accessing servers or hosts on MN the local corporate network 3 22 AirWorks AWK 3121 Web Console Configuration Configuring Virtual LAN NOTE VLAN Settings To configure the AWK s VLAN use the VLAN Setting page to configure the ports VLAN Settings AP only Management LAN ID LAN ASLON Please use comma to See a LAN EU MOXA SSID2 SSID3 SSID4 SSIDS SSID6 SSID SSID8 SSID9 Management VLAN ID VLAN
61. hat actually encrypt outgoing packets and decrypt incoming packets WPA WPA2 Enterprise Also called WPA WPA2 EAP Extensible Authentication Protocol In addition to device based authentication WPA WPA2 Enterprise enables user based authentication via EEE802 1X The AWK 3121 can support three EAP methods EAP TLS EAP TTLS and EAP PEAP WLAN Security Settings Security mode Security mode Setting Description Faactory Default No authentication Open WEP Static WEP is used WPA2 Fully supports EEE802 11i with TKIP AES 802 1X WPA and WPA2 are not supported in WDS Bridge mode Open For security reasons you should NOT set security mode to Open System since authentication and data encryption are NOT performed in Open System mode 3 11 AirWorks AWK 3121 Web Console Configuration WEP According to the EEE802 11 standard WEP can be used for authentication and data encryption to maintain confidentiality Shared or Shared Key authentication type is used if WEP authentication and data encryption are both needed Normally Open or Open System authentication type is used when WEP data encryption is run with authentication When WEP is enabled as a security mode the length of a key So called WEP seed can be specified as 64 128 bits which is actually a 40 104 bit secret key with a 24 bit initialization vector The AWK 3121 provides 4 entities of WEP key settings that can be selected to use with Key
62. ic Write commnulty private SNMP agent version Wi Vec ka Admin authentication type Admin privacy type Privacy key Private MIB information Device object ID enterprise 8691 15 7 Enable Enables SNMP Agent Disable Disables SNMP Agent Remote Management Allow remote management via SNMP agent Disable Disallow remote management via SNMP agent Read community for V1 V2c V1 V2c Read Use a community string match with a maximum of 31 public Community characters for authentication This means that the SNMP agent can access all objects with read only permissions using this community string 3 30 AirWorks AWK 3121 Web Console Configuration Write community for V1 V2c V1 V2c Read Write Use a community string match with a maximum of 31 private Community characters for authentication This means that the SNMP agent can accesses all objects with read write permissions using this community string SNMP agent version V1 V2c V3 or Select the SNMP protocol version used to manage the switch V1 V2c V1 V2c or V3 only Admin auth type for V1 V2c V3 and V3 only Use admin account to access objects No authentication No Auth MD5 Provide authentication based on the HMAC MD5 algorithms 8 character passwords are the minimum requirement for authentication SHA Provides authentication based on HMAC SHA algorithms 8 character passwords are the a minimum requirement for authentication Admin private key
63. ilter The AWK 3121 s IP protocol filter is a policy based filter that can allow or filter out IP based packets with specified IP protocol and source destination IP addresses The AWK 3121 provides 8 entities for setting IP protocol and source destination IP addresses in your filtering policy Four IP protocols are available All ICMP TCP and UDP You must specify either the Source IP or the Destination IP By combining IP addresses and netmasks you can specify a single IP address or a range of IP addresses to accept or drop For example IP address 192 168 1 1 and netmask 255 255 255 255 refers to the sole IP address 192 168 1 1 IP address 192 168 1 1 and netmask 255 255 255 0 refers to the range of IP addresses from 192 168 1 1 to 192 168 255 Remember to check the Active check box for each entity to activate the setting IP Protocol Filters Enable Disable Y Policy Drop No Active Protocol Source IP Source netmask Destination IP Destination netmask o WEAD 9 E Eta A o la ACC Enables IP protocol filter Disable Disables IP protocol filter Policy Only the packets fitting the entities on the list can be allowed Drop Any packet fitting the entities on the list will be denied ATTENTION Be careful when you enable the filter function Drop no entity on list is activated all packets are allowed Accept no entity on list is activated all packets are denied 3 26 A
64. import export e Dedicated antenna selection e Free firmware update for more advanced functions e RS 232 console management e 2DI 1DO for on site monitoring and warnings e Wide 40 to 75 C operating temperature range T model e Redundant 24 VDC power inputs or EEE802 3af Power over Ethernet e DIN Rail or wall mounting e P30 protected high strength metal housing 1 2 AirWorks AWK 3121 Introduction Product Specifications WLAN Interface Standards IEEE 802 11a b g for Wireless LAN IEEE 802 11i for Wireless Security IEEE 802 3u for 10 100BaseT X IEEE 802 3af for Power over Ethernet IEEE 802 1D for Spanning Tree Protocol IEEE 802 1w for Rapid STP IEEE 802 1Q VLAN Spread Spectrum and Modulation typical e DSSS with DBPSK DQPSK CCK e OFDM with BPSK QPSK 16QAM 64QAM e 802 11b CCK O 11 5 5 Mbps DQPSK O 2 Mbps DBPSK 11 Mbps e 802 11a g 64QAM O 54 48 Mbps 16QAM 36 24 Mbps QPSK 18 12 Mbps BPSK 9 6 Mbps Operating Channels central frequency US 2 412 to 2 462 GHz 11 channels 5 18 to 5 24 GHz 4 channels EU 2 412 to 2 472 GHz 13 channels 5 18 to 5 24 GHz 4 channels LP 2 412 to 2 472 GHz 13 channels OFDM 2 412 to 2 484 GHz 14 channels DSSS 5 18 to 5 24 GHz 4 channels for W52 Security e SSID broadcast enable disable e Firewall for MAC IP Protocol Port based filtering e 64 bit and 128 bit WEP encryption WPA WPA2 Personal and Enterprise IEEE 802 1X RADIUS TKIP and AE
65. in alarm emails Setting System Info items makes it easier to identify the different AWK 3121 units connected to your network System Info Settings Device name AWK 3121 9547 Device location Device description Device contact information Device name Max 31 of characters This option is useful for specifying the role or application of AWK 3121_ lt Serial different AWK 3121 units No of this AWK 3121 gt Device location Max of 31 characters Specifies the location of different AWK 3121 units Device description Max of 31 characters Use this space to record amore detailed description of the None AWK 3121 3 4 AirWorks AWK 3121 Web Console Configuration Device contact information Max of 31 characters Provides information about whom to contact in order to resolve None problems Use this space to record contact information of the person responsible for maintaining this AWK 3121 Network Settings The Network Settings configuration panel allows you to modify the usual TCP IP network parameters An explanation of each configuration item is given below Network Settings IP configuration Static IP address Static Subnet mask 255 255 255 0 Gateway Primary DNS server Secondary DNS server IP configuration T DHCP he AWK 3121 s IP address will be assigned automatically by Static the network s DHCP server Set up the AWK 3121 s IP address manually IP address AWK 3121 s IP a
66. irWorks AWK 3121 Web Console Configuration TCP UDP Port Filter The AWK 3121 s TCP UDP port filter is a policy based filter that can allow or filter out TCP UDP based packets with a specified source or destination port The AWK 3121 provides 8 entities for setting the range of source destination ports of a specific protocol In addition to selecting TCP or UDP protocol you can set either the source port destination port or both The end port can be left empty if only a single port is specified Of course the end port cannot be larger then the start port The Application name is a text string that describes the corresponding entity with up to 31 characters Remember to check the Active check box for each entity to activate the setting TCP UDP Port Filters Enable Disable r Folicy Drop No fictive Source port Destination port Protocol Application name Po ee ed Ps eA E 2 E ad TCR Po EO E ed JJ SS Enable Enables TCP UDP port filter Disable Disables TCP UDP port filter Policy Only the packets fitting the entities on list can be allowed Any packet fitting the entities on list will be denied ATTENTI ON Be careful when you enable the filter function Drop no entity on list is activated all packets are allowed Accept no entity on list is activated all packets are denied 3 27 AirWorks AWK 3121 Web Console Configuration RSTP Settings for WDS Maste or Slave only
67. ity aka Ready to Install Setup le now ready to begin installing AWE Search Utility on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program Flesko a MLS E Search Utility Start Menu folder AWE Search Utility Install Cancel 6 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen 7 Click Finish to complete the installation of AWK Search Utility 2 Setup AWE Search Utility Completing the AWK Search Utility Setup Wizard Setup has finished installing AWE Search Utility on your computer The application may be launched by selecting the Installed icons Click Finish to exit Setup AirWorks AWK 3121 Software Installation and Configuration Configuring AWK Search Utility The Broadcast Search function is used to locate all AWK 3121 APs that are connected to the same LAN as your computer After locating an AWK 3121 you will be able to change its IP address Since the Broadcast Search function searches by TCP packet and not IP address it doesn t matter if the AWK 3121 is configured as an AP or Client In either case APs and Clients connected to the LAN will be located regardless of whether or not they are part of the same subnet as the host 1 Start th
68. ll need access to a notebook computer or PC equipped with an Ethernet port The AWK 3121 has a default IP address that must be used when connecting to the device for the first time e Step 1 Select the power source The AWK 3121 can be powered by a DC power input or PoE Power over Ethernet The AWK 3121 will use whichever power source you choose e Step 2 Connect the AWK 3121 to a notebook or PC Since the AWK 3121 supports MDI MDI X auto sensing you can use either a straight through cable or crossover cable to connect the AWK 3121 to a computer The LED indicator on the AWK 3121 s LAN port will light up when a connection is established e Step 3 Set up the computer s IP address Choose an IP address on the same subnet as the AWK 3121 Since the AWK 3121 s default IP address is 192 168 127 253 and the subnet mask is 255 255 255 0 you should set the IP address of the computer to 192 168 127 xxx NOTE After you select Maintenance gt Load Factory Default and click the Submit button the AWK 3121 will be reset to factory default settings and the IP address will be reset to 192 168 127 253 e Step 4 Use the web based manager to configure the AWK 3121 Open your computer s web browser and type http 192 168 127 253 in the address field to access the homepage of the web based Network Manager Before the homepage opens you will need to enter the user name and password as shown in the following figure For first time configuration enter the
69. mation you exchange with this site cannot be viewed or y changed by others However there it a problem with the site s security certificate A The security certificate mas issued by a company vou have not chosen to trust View the certificate to determine whether you want to trust the certifying authority e The secunty certificate date is valid The secunty certificate has a valid name matching the name of the page you are tying ho wiew Do you want to proceed if View Certificate 5 4 AirWorks AWK 3121 Other Console Considerations 3 Select Yes to accept the certificate issued by Moxa IW and then enter the AWK 3121 s web browser interface secured via HTTPS SSL You can see the protocol in URL is https Then you can use the menu tree on the left side of the window to open the function pages to access each of AWK 3121 s functions 3 MOXA AWK 3121 JP 192 168 127 253 Microsoft Internet Explorer a File Edit View Favorites Tools Help Back gt 7 x BE Search 5 2 Favorites E Eb J Py Address El https 1192 168 127 253 home asp h Go gt Total Solution for Industrial Wireless Networking J Main Menu Overview LD Overview HEJ Basic Settings FIL Wireless Settings len A Cathkin a All information on this page are active values System info Disabling Telnet and Browser Access If you are connecting the AWK 3121 to a public network but do not intend to use its management functio
70. nd make it easy to establish and maintain your wireless network The following topics are covered in this chapter O Web Browser Configuration O Overview O Basic Settings gt System Info Settings gt Network Settings gt Time Settings O Wireless Settings a Operation Mode O Basic Wireless Settings gt WLAN Security Settings gt Advanced Wireless Settings gt WLAN Certification Settings for EAP TLS in Client mode only O Advanced Settings gt Using Virtual LAN gt Configuring Virtual LAN gt DHCP Server for AP mode only gt Packet Filters gt RSTP Settings for WDS Maste or Slave only gt SNMP Agent gt Link Fault Pass Through for Client Slave mode only O Auto Warning Settings gt System Log gt Syslog gt E mail gt Relay gt Trap O a Status gt Wireless Status gt Associated Client List for AP mode only gt DHCP Client List for AP mode only gt System Log gt Relay Status gt DI and Power Status Maintenance Console Settings Ping Firmware Upgrade gt gt gt gt Config Import Export gt Load Factory Default gt Password gt Misc Settings Save Configuration Restart Logout AirWorks AWK 3121 Web Browser Configuration NOTE 1 Open your web browser e g Moxa AWK 3121 s web browser interface provides a convenient way to modify its configuration and access the built in monitoring and network administration functions The recommen
71. nner authentication procedures TTLS uses the encrypted channel to exchange attribute value pairs AVPs while PEAP uses the encrypted channel to start a second EAP exchange inside of the tunnel The AWK 3121 provides MS CHAP V2 merely as an EAP method for inner authentication WLAN Security Settings Security mode WPA type Encryption method EAP Protocol Inner EAP protocol Anonymous User name Password Inner EAP protocol MS CHAP V2 Anonymous Enterprise MS CHAP V2 gt Microsoft CHAP version 2 is used MS CHAP V2 Factory Default Max of 31 characters A distinct name used for outer authentication None User name amp Password Advanced Wireless Settings User name and password used in inner authentication None Additional wireless related parameters are presented in this section to help you set up your wireless network in detail Advanced Wireless Settings Transmission rate Transmission power Beacon interval DTIM interval Fragmentation threshold RTS threshold Transmission distance Noise protection Transmission enhancement Antenna EAPOL version WMM Full 11a channel support Turbo roaming 40 1000ms 1 15 256 2346 256 2346 500 500 11000m Disable Y Disable Auto 1 T Disable Disable Enable 3 17 AirWorks AWK 3121 Web Console Configuration Transmission Rate The AWK 3121 senses and adjusts the data rate automatically Available rate
72. ns Select the appropriate COM port for Console Connection 115200 for Baud Rate 8 for Data Bits None for Parity and 1 for Stop Bits Click on the Terminal tab and select VT100 or ANSI for Terminal Type Click on OK to continue Property Ed Property Communication Parameter Terminal File Transfer Capturing Communication Parameter Terminal File Transfer Capturing COM Options Terminal Type WT OD r Forts COMI ARSI sea Bled ete Dumb Terminal Option e Tenra Transmit Data Bits Send Enter Ley As Parity Stop Bits Flow Control Output State Receive ATSACTS OTRA ON OFF CR Translation SON ACOEE ATS ON C OFF LF Translation 5 2 AirWorks AWK 3121 Other Console Considerations NOTE 4 The Console login screen will appear Log into the RS 232 console with the login name default admin and password default root if no new password is set E COM1 115200 None 8 1 VT100 AE e WE 3121 U8 J DTR POOL login admin RATS Password State OPEN m m Heady 5 The AWK 3121 s device information and Main Menu will be displayed Please follow the description on screen and select the administration option you wish to perform EY COM1 115200 None 8 1 V1100 AWK 3121 U5 LAN MAC Address O0O 30 e5 09 21 33 Serial Ho 45 Firmware Version 1 0 build 08060411 il System Info Settings 2 Time Settings 3 Network Settings 4 Pestart igi Quit ey in
73. ns over the network then we suggest disabling both Telnet Console and Web Configuration Please run Maintenance gt Console Settings to disable them as shown in the following figure Console Settings HTTP console C Enable Disable HTTPS console Enable Disable Telnet console C Enable Disable SSH console Enable Disable Submit A References This chapter provides more detailed information about wireless related technologies The information in this chapter can help you administer your AWK 3121s and plan your industrial wireless network better The following topics are covered in this appendix O O O O O O Wireless Distribution System WDS Beacon DTI M Fragment RTS Threshold STP and RSTP gt The STP RSTP Concept gt Differences between RSTP and STP AirWorks AWK 3121 References Wireless Distribution System WDS Traditionally APs are connected via Ethernet LAN ports By using a Wireless Distribution System WDS APs can communicate with one another wirelessly For example AP 2 acts as an access point for the notebook computers or other EEE802 11 enabled clients and forwards packets sent from the notebook computers to AP 1 through WDS Then AP 1 forwards the packets to the Ethernet LAN Packets destined for the notebook computers follow a reverse path from the Ethernet LAN through the APs to the notebook computers In this way AP 2 acts as an AP repeater Notebook Compu
74. nts Input Voltage 12 to 48 VDC redundant dual DC power inputs or 48 VDC Power over Ethernet I EEE 802 3af compliant Connector 10 pin removable terminal block Power Consumption e 0 121 to 0 494 A 12 to 48 VDC e 0 3 A 24 VDC Reverse Polarity Protection Present Regulatory Approvals Safety EN60950 1 UL60950 1 Radio EN300 328 EN301 893 TELEC 1 4 AirWorks AWK 3121 Introduction A A EMC EN301 489 1 17 FCC Part 15 EN55022 55024 EC61000 6 2 4 Transportation Directive 72 245 EEC for e E mark Hazardous Location UL cUL Class Div 2 ATEX Class Zone 2 Note Please check Moxa s website for the most up to date certification status Warranty Warranty Period 5 years Details See www moxa com warranty ATTENTION For EXPLOSION PROOF application the AWK 3121 are designed and certified to meet the requirements of CID2 and ATEX and shall be mounted in a suitable enclosure rate to at least IP54 and Pollution Degree 2 as defined in EN60529 and used within its rated electrical and environmental ratings ATTENTION e The AWK 3121 is NOT a portable mobile device and should be located at least 20 cm away from the human body e The AWK 3121 is NOT designed for the general public A well trained technician should be enlisted to ensure safe deployment of AWK 3121 units and to establish a wireless network Functional Design LED Indicators The LEDs on the front panel of the AWK 3121 provide a q
75. od TKIP EAP Protocol TLS Certificate issued to Certificate issued by Certificate expiration date You can check the current certificate status in Current Status if it is available e Certificate issued to Shows the certificate user e Certificate issued by Shows the certificate issuer e Certificate expiration date Indicates when the certificate has expired 3 15 AirWorks AWK 3121 Web Console Configuration EAP TTLS It is usually much easier to re use existing authentication systems such as a Windows domain or Active Directory LDAP directory or Kerberos realm rather than creating a parallel authentication system As a result TTLS Tunneled TLS and PEAP Protected EAP are used to support the use of so called legacy authentication methods TTLS and PEAP work in a similar way First they establish a TLS tunnel EAP TLS for example and validate whether the network is trustworthy with digital certificates on the authentication server This step establishes a tunnel that protects the next step or inner authentication and consequently is sometimes referred to as outer authentication The TLS tunnel is then used to encrypt an older authentication protocol that authenticates the user for the network As you can see digital certificates are still needed for outer authentication in a simplified form Only a small number of certificates are required which can be generated by a small certificate authority
76. og 2 da Ha System Log Event Types 23 Syslog z 0 Syslog Event Types pod 0 Syslog Server Settings 2 ea E mail E gm E mail Event Types Essential settings related to establishing a wireless network Advanced features to support additional network management and secure wired and wireless communication Note These advanced functions are all optional Application oriented device management functions to set up events traps and reactions via relay warning e mail and SNMP notification i J E mail Server Settings 2a Sui Note These functions are all optional 3 HCJ Relay Event Types o Ey Trap 0O Trap Event Types 03 SNMP Trap Recelver Settings 2a Status Wireless Status Associated Client List DHCP Client List System Log Real time status information for monitoring wired wireless network performance advanced services and device management functions Relay Status DI and Power Status RSTA Status alntenance Console Settings Pina Firmware Upgrade Functions for maintaining the AWK 3121 and for Contig Import Export Load Factory Default Password diagnosing the network Tr a ne aes ae On demand functions to support the web based 0 Save Configuration C Restart 23 Logout console management operation 2 5 3 Web Console Configuration In this chapter we explain all aspects of web based console configuration Moxa s easy to use management functions help you set up your AWK 3121 a
77. or technical support The following topics are covered in this appendix O About This User s Manual O DoC Declaration of Conformity gt Federal Communication Commission Interference Statement gt RETTE Compliance Statement O Firmware Recovery AirWorks AWK 3121 Supporting Information About This User s Manual A This manual is mainly designed for but nto limited to the following hardware and firmware for the AWK 3121 e Hardware Rev 1 2 e Firmware Ver 1 10 You are strongly recommended to visit Moxa s website http www moxa com and find the latest product datasheet firmware QIG Quick Installation Guide UM User s Manual and related information NOTE You can find out the hardware revision number of AWK 3121 on the side label MOXA Model Name AWK 3121 US Production S N LOREM MAC Address 09 00 E9 09 21 93 Rev 1 2 The firmware version number can be seen on the Overview page as follow Overview All information on this page are active values System info Model name AWK 3121 US Device name AWK 3121 0000 Serial No 0 System up time O days 00h 02m 02s Firmware version 1 2 Build 09012300 DoC Declaration of Conformity Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against h
78. ot in Bridge WDS Mode WLAN function is in Client Slave mode and AWK has established a link with an AP CLI ENT Green WLAN data communication is run in Client Slave mode WLAN is not in Client Mode or AWK has not established a link with an AP WLAN functions in AP Bridge Master mode Amber WLAN s data communication is run in AP Bridge Master mode Off WLAN is not in use or not working properly TP Port LED Indicators Port Interface TP port s 100Mbps link is active Green Data is being transmitted at 100 Mbps Off TP port s 100Mbps link is inactive TP port s 10Mbps link is active Amber Data is being transmitted at 10 Mbps TP port s 100Mbps link is inactive Amber ATTENTION A The FAULT SIGNAL CLIENT BRIDGE and WLAN LEDs lighting up simultaneously and blinking at one second intervals indicates that the system has failed to boot This may be due to improper operation or an uncontrollable factor such as an unexpected shutdown during firmware update Instructions on how to recover the firmware can be found in Chapter 6 in the Firmware Recovery section Beeper The beeper emits two short beeps when the system is ready 1 6 AirWorks AWK 3121 Introduction Reset Button The RESET button is located on the top panel of the AWK 3121 You can reboot the AWK 3121 or reset it to factory default settings by pressing the RESET button with a pointed object such as an unfolded paper clip e System reboot Hold the RE
79. ot located on the same network switch Network reconfiguration can be done through software instead of physically relocating devices VLANs now extend as far as the reach of the access point signal Clients can be segmented into wireless sub networks via SSID and VLAN assignment A Client can access the network by connecting to an AP configured to support its assigned SSID VLAN Benefits of VLANs VLANs are used to conveniently efficiently and easily manage your network in the following ways e Manage adds moves and changes from a single point of contact e Define and monitor groups e Reduce broadcast and multicast traffic to unnecessary destinations e Improve network performance and reduce latency e Increase security e Secure network restricts members to resources on their own VLAN e Clients roam without compromising security VLAN Workgroups and Traffic Management The AP assigns clients to a VLAN based on a Network Name SSID The AP can support up to 9 SSIDs per radio interface with a unique VLAN configurable per SSID The AP matches packets transmitted or received to a network name with the associated VLAN Traffic received by a VLAN is only sent on the wireless interface associated with that same VLAN This eliminates unnecessary traffic on the wireless LAN conserving bandwidth and maximizing throughput In addition to enhancing wireless traffic management the VLAN capable AP supports easy assignment of wireless users to work
80. ot support DFS so only U NII Low channels 36 40 44 and 48 are supported by default If you want to enable the Full 11a channel support option keep in mind that your wireless devices may interfere with radar systems which may violate local laws If you are not sure about this we recommend that you keep this option disabled Updated firmware that supports DFS will be available soon Turbo Roaming for Client mode only Enable Disable Moxa s Turbo Roaming can enable rapid handover when the Disable AWK 3121 as a client roams among a group of APs When Turbo Roaming is enabled the RF type AP alive check and Scan channels will be shown as follows RF type shows the current RF type that this client is using AP alive check will check if the AP connection is still available When this function is enabled a check will be done every 10 ms You can set up Scan channels for the APs among which this client is going to roam There are three Scan channels available Note that the Scan channels may need to be modified when the RF type is changed For example channel 36 is not available in B G or B G Mix mode Turbo roaming Enable RF type a AP alive check ae 3 20 AirWorks AWK 3121 Web Console Configuration WLAN Certification Settings for EAP TLS in Client mode only When EAP TLS is used a WLAN Certificate will be required at the client end to support WPA WPA2 Enterprise The AWK 3121 can support the PKCS 12 also
81. ppear Press Ctrl C to enter the menu and select 1 to start the firmware upgrade process IP address of ANE 3121 192 168 1 2 IP address of TETP server 192 168 1 1 1 Start to firmvare upgrade using the above network setting immediately 2 Change the network settings Enter your selection l 2 enter for abort 1 Select O in the sub menu to load the firmware image via LAN and then enter the file name of the firmware to start the firmware recovery Load method select 0 Load trom LAN 1 Load trom serial with modem q Abort select Please select item JU Please input load image name Default file name AWEK 3121 rom User Input file name AWK 3121 1 0 rom B 4
82. ransition Off gt On LAN link On LAN link Off Traps can be used to signal abnormal conditions notifications to a management station This trap driven notification can make your network more efficient Because a management station usually takes care of a large number of devices that have a large number of objects it will be overloading for the management station to poll or send requests to query every object on every device It would be better if the managed device agent could notify the management station by sending a message known as a trap for the event 3 35 AirWorks AWK 3121 Web Console Configuration Trap Event Types Trap Event Types Event Active Cold start F Warm start F Power 1 transition On gt 0ff C Power 1 transition Off gt 0n C Power 2 transition On gt 0ff F Power 2 transition Off gt 0n F PoE transition On gt Off F PoE transition Off gt On C Configuration changed F Console authentication failure F DI 1 transition On gt 0ff C DI 1 transition Off gt On C DI 2 transition On gt 0ff F DI 2 transition Off gt On F LAN link on C LAN link off F SNMP Trap Receiver Settings SNMP traps are defined in SMIv1 MIBs SNMPv1 and SMIv2 MI Bs SNMPv2c The two styles are basically equivalent and it is possible to convert between the two You can set the parameters for SNMP trap receivers through the web page SNMP Trap Receiv
83. reboot the AWK 3121 US Restart You will not be able to run any of the AWK 3121 s functions while the system is rebooting Logout Logout helps users disconnect the current HTTP or HTTPS session and go to the Login page For security reasons we recommend you logout before quitting the console manager Logout Click Logout button to defalut Login page Logout 3 43 4 Software Installation and Configuration The following topics are covered in this chapter O Overview O AWK Search Utility gt Installing AWK Search Utility gt Configuring AWK Search Utility AirWorks AWK 3121 Software Installation and Configuration Overview The Documentation amp Software CD included with your AWK 3121 is designed to make the installation and configuration procedure easy and straightforward This auto run CD includes AWK Search Utility to broadcast search for all AWK s accessible over the network the AWK 3121 User s Manual and Quick Installation Guide AWK Search Utility Installing AWK Search Utility Click the INSTALL UTILITY button in the AWK Installation CD auto run window to install AWK Search Utility Once the program starts running click Yes to proceed 1 Click Next when the Welcome screen opens to proceed with the installation ig Setup AWK Search Utility Sele Welcome to the AWK Search Utility Setup Wizard This will install AWE Search Utility on pour computer Iki recommended that you clo
84. s Users can manually select a target transmission data rate Transmission Power Auto Specifies wireless signal coverage by automatically selecting Full the strength of Tx power NOTE Tx power at Full e US model 17 dB e EU model 16 dB e JP model 18 dB RF type A Channel 36 48 Auto Specifies wireless signal coverage by automatically selecting Full the strength of Tx power NOTE Tx power at Full e US model 14 dB e EU model 16 dB e JP model 14 dB Beacon Interval for AP Master mode only Beacon Interval Indicates the frequency interval of the beacon 100 ms 40 to 1000 ms DTI M Interval for AP Master mode only Data Beacon Rate Indicates how often the AWK 3121 sends out a Delivery Traffic 1 1 to 15 Indication Message Fragmentation threshold Fragment Length Specifies the maximum size a data packet before splitting and 2346 256 to 2346 creating another new packet RTS threshold RTS CTS Threshold Determines how large a packet can be before the Access Point 2346 256 to 2346 coordinates transmission and reception to ensure efficient communication 3 18 AirWorks AWK 3121 Web Console Configuration NOTE You can refer to the related glossaries in Chapter 5 for detailed information about the above mentioned settings By setting these parameters properly you can better tune the performance of your wireless network Transmission distance Distance or max range
85. se all other applications before Continuing Click Nest to continue or Cancel to exit Setup 2 Setup AWE Search Utility Select Destination Location Where should AE Search Utility be installed O al seek Urin niate fla ala To continue click Next IF you would like to select a different folder click Browse C Program Files MoxasaVk WaavK Search Utility Al least 2 5 MB of free disk space is required AirWorks AWK 3121 Software Installation and Configuration 3 Click Next to create the program s shortcut files to the default directory or click Browse to select an alternate location El Setup AWK Search Utility See Select Start Menu Folder Where should Setup place the program s shortcuts nu FA Setup will create the program s shortcuts in the following Start Menu Falder To continue click Next IF you would like to select a different folder click Browse AWK Search Utility 4 Click Next to select additional tasks 2 Setup AWK Search Utility Jia Ex Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would like Setup to perform while installing AWE Search Utility then click Next Additional icons Create a Quick Launch icon 4 3 AirWorks AWK 3121 Software Installation and Configuration 5 Click Next to proceed with the installation The installer then displays a summary of the installation options El Setup AWK Search Util
86. st AWK 3121 connected to notebook A and change the second or third AWK 3121 connected to notebook B to Client mode and then configure the notebooks and AWK 3121 units properly AP IP 192 168 127 253 Client IP 192 168 127 252 A el el maa m PING SSID MOXA oe ae a t a ae Notebook B Notebook A IP 192 168 127 1 IP 192 168 127 2 After setting up the testing environment open a DOS window on notebook B At the prompt type ping lt IP address of notebook A gt and then press Enter A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make sure the connections are correct 2 4 AirWorks AWK 3121 i Function ee Main Menu HOJ Overview Getting Started Quick overview of the AWK 3121 s status aa Basic Settings Basic settings for administering the AWK 3121 System Info Settings i Q Network Settings J Time Settings Wireless Settings e 0 Operation Mode a WLAN 2 eC Basic Wireless Settings qu WLAN Security Settings C Advanced Wireless Setting CJ WLAN Certificate Settings aa Advanced Settings gm WLAN Settings C DHCP Server Packet Filters 7 Y MAC Filters CI IP Protocol Filters MCI TCP UDP Port Filters C RSTP Settings 0 SNMP Agent l i 0I Link Fault Pass Through PS Auto Warning Settings System L
87. tatus On Off Power 1 status On Power 2 status Off PoE status Off DI 1 status Off DI 2 status Off Maintenance Maintenance functions provide the administrator with tools to manage the AWK 3121 and wired wireless networks Console Settings You can enable or disable access permission for the following consoles HTTP HTTPS Telnet and SSH connections For more security we recommend you only allow access to the two secured consoles HTTPS and SSH Console Settings HTTP console e Enable Disable HTTPS console e Enable Disable Telnet console Enable Disable SSH console e Enable Disable Submit Ping Ping helps to diagnose the integrity of wired or wireless networks By inputting a node s IP address in the Destination field you can use the ping command to make sure it exists and whether or not the access path is available Ping Destination 192 168 253 2 3 39 AirWorks AWK 3121 Web Console Configuration If the node and access path are available you will see that all packets were successfully transmitted with no loss Otherwise some or even all packets may get lost as shown in the following figure Ping Destination PING 192 168 127 2 192 168 127 2 56 data bytes 192 168 127 2 ping statistics 4 packets transmitted O packets received 100 packet loss Firmware Upgrade The AWK 3121 can be enhanced with more value added functions by installing firmware
88. ter AP 2 302 11 enabled client By using WDS two or more LAN segments can be connected wirelessly As illustrated in the above figure a pair of wireless LAN to LAN bridges is used to connect two LAN segments Since the AP is WDS enabled it can be used as a wireless bridge WDS Link Bridge 1 Bridge 2 It is a good idea to plan your wireless network by drawing a diagram so that you know how each AWK 3121 is connected to other peer APs or wireless bridges by WDS and how bridges are connected to other peer bridges by WDS See the following figure for an example of a network planning diagram LAN Segment 2 LAN Segment 3 Bridge 2 LAN Segment 1 Bridge 3 Bridge 1 Bridge 4 LAN Segment 5 Bridge 5 LAN Segment 4 lL WDS link AirWorks AWK 3121 References ATTENTION Be sure to eliminate loops from networks that consist of wireless bridges Ethernet switches Ethernet links and WDS links If any loops exist packets will circle around the loops and network performance will be seriously degraded The following figure shows a network topology containing a loop Ethernet E i Switch Hub Bridge 4 Ethernet link i a WDS link Bridge 2 Beacon A beacon is a packet broadcast by the AP to keep the network synchronized A beacon includes the wireless LAN service area the AP address the Broadcast destination address a time stamp Delivery Traffic Indicator Maps DTIM and the
89. the left side of the window to open the function pages to access each of the AWK 3121 s functions E MOXA AWK 3121 US 192 168 127 253 Microsoft Internet Explorer File Edit View Favorites Tools Help Back ka gt oF x E A yo Search 5 2 Favorites C4 E T Address 2 https 192 168 127 253 home asp Go NO YN eee Lye Pyle yy Total Solution for Industrial Wireless Networking Overview A Basic Settings All information on this page are active values EH Wireless Settings 3 System info Ej Advanced Settings Sa Model name AWK S121 US peer ae a Device name AWK 3121_0049 Fl Status z La te Serial No 49 a ee System up time O days OOh 00m 28s Speer aca Firmware version 1 0 build 08061615 I Restart a al Logout Device info In the following paragraphs we describe each AWK 3121 management function in detail A quick overview is available in this manual in the Function Map section of Chapter 2 NOTE The model name of the AWK 3121 is shown as AWK 3121 XX where XX indicates the country code The country code indicates the AWK 3121 version and which bandwidth it uses We use AWK 3121 US as an example in the following figures The country code and model name that appears on your computer screen may be different than the one shown here NOTE For security reasons you will need to log back into the AWK 3121 after a 5 minute time out Overview The Overview page summarizes the AW
90. tor every one second Section userdisk Cksum error UsaStfeadde gt O b58c5051 Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C to enter Firmware Recoverying Process Press Ctrl C and the following message will appear IP address of ANE 3121 0 0 0 0 IP address of TETP server 0 0 0 0 1 Start to firmware upgrade using the above network setting immediately 2 Change the network settings Enter your selection 1 2 enter for abort A Enter 2 to change the network setting Specify where the AWK 3121 s firmware file on the TFTP server and press y to write the settings into flash memory IP address of AWE 31271 0 0 0 0 IP address of TETP server 0 0 0 0 1 Start to firmware upgrade using the above network setting immediately 2 Change the network settings Enter your selection 1 2 enter for abort 2 IP address of ANE 3121 192 168 1 2 IP address of TFTP server 192 168 1 1 Update RedBoot non volatile configuration continue yen y AWK 3121 restarts and the Press Ctrl C to enter Firmware Recovery Process message will rea
91. ue Increase this port s priority as a node on the Spanning Tree 128 selected by user topology by inputting a lower number Port cost Enable Disable Input a higher cost to indicate that this port is less suitable as a 2000000 node for the Spanning Tree topology Edge port Checked unchecked Sets a port which no BPDU expectedly goes through as an unchecked except edge port AP port We recommend you set an edge port for the port which is connected to a non STP RSTP sub network or an end device PLC RTU etc aS opposed to network equipment This can prevent unnecessary waiting and negotiation of STP RSTP protocol and accelerate system initialization When an edge port receives BPDUs it can still function as an STP RSTP port and start negotiation Setting an edge port is different from disabling STP RSTP on a port If you disable STP RSTP a port will not deal with STP RSTP BPDUs at all Port Status Port Status indicates the current Spanning Tree status of this port Use Forwarding for normal transmission or Blocking to block transmission SNMP Agent The AWK 3121 supports SNMP V1 V2c V3 SNMP V1 and SNMP V2c use a community string match for authentication which means that SNMP servers access all objects with read only or read write permissions using the community string public private default value SNMP V3 which requires you to select an authentication level of MD5 or SHA is the most secure protocol You can also
92. uick and easy means of determining the current operational status and wireless settings The FAULT LED indicates system failures and user configured events If the AWK 3121 cannot retrieve the IP address from a DHCP server the FAULT LED will blink at one second intervals The SIGNAL LEDs indicate Signal strength and only operate in Client mode Fault LED E Signal a Strength F LEDs SIGNAL 9 cit BRIDGE lt WLAN 1 5 AirWorks AWK 3121 Introduction The following table summarizes how to read the device s wireless settings from the LED displays More information is available in Chapter 3 in the Basic Wireless Settings section NICE Description Front Panel LED Indicators System MT Euan Power is being supplied from powerinput 1 Power is not being supplied frompower input 1 MTS r n lt Power is being supplied from power input 2 Power is not being supplied from power input 2 a Power is being supplied via PoE off Power is not being supplied via PoE Cannot get an IP address from the Blink slow l DHCP server interval 1 sec FAULT Blink OA IP address conflict interval 0 5 sec Off Error condition does not exist Green Software Ready FATE po Green The AWK has been located by AWK Search Utility interval 1sec Red Booting error condition Green Signal level for Client Slave mode only 5 LEDS or 2 WLAN function is in Bridge WDS Mode BRI DGE Green Off WLAN is n
93. uld be installed and operated with a minimum distance of 20 cm between the radiator amp your body This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC 15 407 e Within the 5 15 5 25 GHz band U NII devices will be restricted to indoor operations to reduce any potential for harmful interference to co channel MSS operations The availability of some specific channels and or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination The firmware setting is not accessible by the end user R amp TTE Compliance Statement Moxa declares that the apparatus AWK 3121 complies with the essential requirements and other relevant provisions of Directive 1999 5 EC This equipment complies with all the requirements of DIRECTIVE 1999 5 CE OF THE EUROPEAN PARLI AMENT AND THE COUNCIL OF 9 March 1999 on radio equipment and telecommunication terminal equipment and the mutual recognition of their conformity R amp TTE The R amp TTE Directive repeals and replaces in the directive 98 13 EEC Telecommunications Terminal Equipment and Satellite Earth Station Equipment as of April 8 2000 Safety This equipment is designed with the utmost care for the safety of those
94. upgrades The latest firmware is available at Moxa s download center Before running a firmware upgrade make sure the AWK 3121 is off line Click the Browse button to specify the firmware image file and click Firmware Upgrade and Restart to start the firmware upgrade After the progress bar reaches 100 the AWK 3121 will reboot itself When upgrading your firmware the AWK 3121 s other functions are forbidden Firmware Upgrade Select update image CVAWK3121_1 0_Build_08071116 rom Browse Firmware Upgrade and Restart ATTENTION Please make sure the power source is stable when you upgrade your firmware An unexpected power breakup may damage your AWK 3121 Config mport Export You can back up or restore the AWK 3121 s configuration with Config Import Export In the Config Import section click Browse to specify the configuration file and click Config I mport button to begin importing the configuration Config Import Select configuration file Browse Config Import In the Config Export section click the Config Export button and save the configuration file onto your local storage media The configuration file is a text file and you can view and edit it with a general text editing tool Config Export Config Export 3 40 AirWorks AWK 3121 Web Console Configuration Load You can also back up or restore the ABC 01 HW Rev 1 1 support only configuration with Config Import Export A
95. who install and use it However special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment All guidelines of this and of the computer manufacturer must therefore be allowed at all times to ensure the safe use of the equipment EU Countries Intended for Use The ETSI version of this device is intended for home and office use in Austria Belgium Denmark Finland France with Frequency channel restrictions Germany Greece Ireland Italy Luxembourg Portugal Spain Sweden The Netherlands and United Kingdom The ETSI version of this device is also authorized for use in EFTA member states Norway and Switzerland EU Countries Not I ntended for Use None Potential Restrictive Use France only channels 10 11 12 and 13 B 3 AirWorks AWK 3121 Supporting Information Firmware Recovery When the LEDs of FAULT Signal Strength CLIENT BRIDGE and WLAN all light up simultaneously and blink at one second interval it means the system booting has failed It may result from some wrong operation or uncontrollable issues such as an unexpected shutdown during firmware update The AWK 3121 is designed to help administrators recover such damage and resume system operation rapidly You can refer to the following instructions to recover the firmware Connect to the AWK 3121 s ES 232 console with 115200bps and N 8 1 You will see the following message shown on the terminal emula