Latch lock
Contents
1. Installation and The warranty conditions are limited to costfree exchange of the product or repair Costs Userman ual and risks caused by transport installation or de installation of the product and all other costs caused by the repairing will not be compensated Liability for consequential loss no matter which type are strictly excluded Congratulations on your purchase of the latch lock RFID125kHz With this decision Obligation of the user you have acquired locking technology with which you can lock and secure furniture without a key but nevertheless in a controlled safe way The user undertakes only to allow persons to work with the latch lock RFID125kHz who The user s manual must be accessible for operators e have been instructed in working with the latch lock RFID125kHz In addition general and local regulations on accident e have read and understood this user s manual Q Important prevention and environmental protection are to be obser ved Warning signals of the latch lock RFID125kHz General safety instructions The lock is equipped with a 3V battery which guarantees up to 20 000 openings The battery level is automatically checked if no opening by radio signal has taken place within 30 days Q Important If the battery level is low or the 20 000 openings have been exceeded the necessary battery replacement is indicated by an audible signal Under certain circumstances the signal may last If the door
2. Technical specifications of the latch lock RFID125kHz Mechanical specification Weight per Set Complete Set 200 Gramm Electrical specifications Equipment class as per Class 2 Directive 1999 5 EC Latch lock RFID125 kHz oF HF radiation output max 66 dBuA m at 10m Frequency band 119 to 135 kHz A CRIZA Ambient conditions Operating temperature 5 C bis 35 C 41 F to 95 F D 4 Relative humidity operation 20 bis 75 not condensing Disposal N Danger The electronics of the latch lock RFID125kHz contains a lithium ion battery Dispose of this battery in accordance with national regulations When disposing of partly discharged batteries ensure that no accidental short circuits can occur between the poles of the battery for example due to key fob in pocket of clothing danger of explosion and fire Fasten the partly discharged battery for transport using non conductive adhesive film in such a way that no short circuits can occur VE vr Z Important Separate electronics of the latch lock RFID125kHz from the other parts and dispose of in accor dance with local regulations and directives Warranty conditions This product was designed and manufactured carefully At the moment of purchase the warranty amounts 12 months for material and manufacturing failures The warranty starts with the date of purchase for 12 months The product can be exchanged prior to certification of the proof of pur chase
3. an encoded chip ID medi z o um This chip can be in the form of an ID card cheque card format or key fob Authorised opening of an electronic lock in wooden furniture with an encoded chip This chip can be in the form of an ID card cheque card format or key fob Function of the lock is only warran ted when mounted on not conductive materials wood plastic The max thickness of the material must not exceed 20 mm If used with higher material thickness or metal doors or doors with metal Components of the latch lock RFID125kHz coatings an external antenna must be used The set contains the following components Forseeable misuse e Latch lock with changeable case e closing part with break and spring di Use of the lock in explosive environments Use of the lock outside of the stipulated specifications scharge for the automatic door opener For damage resulting from incorrect use the customer bears sole responsibility the manufacturer as e 2 pc pins for closing part accepts no liability whatsoever e Battery CR123A i Ig e 125 kHz programming card Conversions or modifications e Transponder 125 kHz Any type of modification to the latch lock RFID125kHz is not permitted e Stickers with Logo The electromagnetic conduct of the latch lock RFID125kHz may be impaired by additions or e 2 fastening plates for 2 leafed doors modifications of any kind e 15 pcs screws Therefore do not carry out any modifications or additions to elec
4. eader panel until a long confirmation signal is sounded gt All saved transponders are deleted the latch is moved into the open position 7 Switch signal tone on or off keep the programming button pressed for max one second gt The signal tone is switched off on ah Note The lock can be operated in two modes Mode Standard latch function Only programmed transponders can lock unlock the drawer lock After the identification of an authorized transponder the latch moves to the open position and then moves back automatically to the closed position Mode open closed bolt function After the identification of an authorized transponder the latch moves to the open position and stops in this position At the next identification of the authorized transponder the latch moves to the close position and stops in this position Q Important Assembling distance ca 20 cm Important RFID Card reader distance Key fob up to 25mm Transponder card up to 40mm Check reading distance after assemb ling the latch lock RFID125kHz EEC Declaration of Conformity in accordance with the directives 2004 108 EC Directive on electro magnetic compatibility EMC 1999 5 EC 1999 Directive on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity R amp TTE Directive on waste electric and electronic equipment WEEE 2011 65 EC Directive on the restriction of
5. is closed when starting up or changing the battery without inserting the battery the for several days in which case automatic unlocking of the lock takes place door cannot be opened via radio signals it is necessary to break the door open Follow the exact instructions for installation and start up of the radio systems and replacement of the batteries Remove the flat battery and to prevent a malfunction wait at least 30 seconds Aim of the latch lock RFID125kHz before inserting a new battery Observe correct polarity at the battery case and the battery The latch lock RFID125kHz is a compact wireless furniture lock for cupboards and drawers It is itself opened with an electric motor when closed the system locks itself Contactless chip technology is used as the key The system is woken up and opened by contactless identification via an Q authorised ID medium on the door Important The ID medium is simple to programme or delete The installation of the lock with the springpo During installation of the lock and strike plate ensure that the door is not pre stressed and wered door opener is possible without drilling holes in the piece of furniture stresses are not transferred to the locking system There is a risk that the latch can no longer open gt malfunction Avoid doors which are pre loaded with a rubber profile Functional description Intended use Authorised opening of an electronic lock in wooden furniture with
6. rance is necessary for the emergency opening in case of the low battery Make sure that the transponder used have a very good reading quality There should always be a comfortable reading distance be available from the front of the cabinet of at least 5 10 mm The mounting distance between two locks should be approx 20 cm There is otherwise a risk of interference of the fields of the card reading panels That can cause discharge of the battery Program the Latch lock RFID125kHz On delivery the lock is neutral Programming can be carried out altered at any time as described in the following Standard configuration means wheater the programming card nor the transpon der is programmed The audible signal is on and the mode standard is activated automatically closing of the latch The programming procedure as described in the following can be done changed at every time 1 Store programming card press the programming button of the lock for 3 seconds until a long signal tone and immediately afterwards a ticking is audible for approx 7 seconds During the ticking you must hold the programming card against the card reader panel until a confirmation tune is audible gt The programming card is now stored Note When using a new programming card the memory will be erased long signal If the programming button has been pressed too short the lock begins to tick and an alarm will sound You have now turned the identification
7. signal off see point 6 2 Store transponder hold the stored program card once against the card reader panel gt A ticking is audible for approx 7 seconds During the ticking hold the transponder key fob against the card reader panel to read it in until a confirmation signal is sounded 2 x 3 short beeps gt The transponder is now stored 3 Check transponder for function hold the transponder once against the card reader panel gt The confirmation signal is sounded again the latch moves back and the lock opens Repeat the process 2 to 3 times to store further transponders You can teach at maximum 1 program ming card and 50 transponder at once The programming card and the transponder can be teached in at several other locks 4 Delete stored transponders individually hold the programming card once against the card reader panel A ticking is heard for approx 7 seconds During the ticking hold the transponder against the card reader panel to delete it until a confirmation signal is sounded gt The transponder is deleted 5 Open the latch e g with programming card and hold the latch in this position Put the pro gramming card 4x to the card reader panel The latch will hold open until a authorised transpon der will reset the hold open function gt All saved transponders are stored the latch is moved into the open position 6 Delete all stored transponders hold the programming card 5x against the card r
8. the use of certain hazardous substances in electrical and electronic equipment recast 2002 96 EC 2003 for the product Latch lock RFID125kHz The following harmonised standards are applied EN 300330 2 V1 3 1 2006 EN 301489 3 V1 4 1 2002 EN ISO 12100 2010 EN 50364 2010
9. tric electronic components es ee the case e Manua Replacement and wear parts and process materials The use of replacement parts from third party manufacturers may lead to dangers Use only aatan original parts or parts approved by the manufacturer Latch lock RFID125kHz installation When unpacking check whether the components as per the description are present Dispose of the packaging in accordance with the applicable regulations of your country Insert battery 1 Normally the battery compartment is already open the cover with screws is contained in an accessory bag Otherwise open the battery compart ment by unscrewing the two M3x6 screws 2 Remove the battery from the blister pack 3 Insert the battery into the battery compartment Observe correct polarity z 4 Screw on the battery case cover with the M3x6mm screws provided gt The device is ready for programming Latch lock RFID125kHz general survey ing hol Screwing holes Programming button Spezial programming connector Card reader panel The programming button has two functions 1 For transponder signal on off gt short press 2 Creating a programming card long press until long beep Install latch lock RFID125kHz on furniture body and door Anschraubplatte fiir Verriegelungsadapter The lock assembly of furniture and the closing part must always be mounted so that the door in the closed state has at least 0 5 mm distance This tole
Download Pdf Manuals
Related Search
Related Contents
Lien - suzuki pure enduro france Manual de Usuario Bemfola 75 IU/0.125 ml Bemfola 150 IU/0.25 ml PlatePatcher 12.1 User Guide - Product Documentation IV-P100 取扱説明書 Orion SKYQUEST XT12 User's Manual 5 - Protections moteurs - Electropoint Distribution SA ParkZone Spitfire Mk IX PNP Copyright © All rights reserved.