1. Mechanical accessories Electrical accessories A Rotary mirror attachment Cooling ROT 10 jacket O J LED digital display air purge Ball and socket unit Ball and socket mounting mounting steel Cooling plate LumaSense Technologies Americas and Australia Europe Middle East Africa India China Sales amp Service Sales amp Service Sales amp Support Center Sales amp Support Center 3301 Leonard Court D 60326 Frankfurt Germany Mumbai India Shanghai China Santa Clara CA 95054 Kleyerstr 90 Tel 1408 727 1600 Tel 49 69 97373 0 Tel 91 22 67419203 Tel 86 21 5882 2277 Fax 1408 727 1677 Fax 49 69 97373 167 Fax 91 22 67419201 Fax 86 21 5887 0077 info lumasenseinc com Visit lumasenseinc com for local sales representation 2010 LumaSense Technologies Rev 12 2010 All rights reserved Specifications are subject to change without notice
2. 08 08 05 QB 400mm 17 14 07 05 Eoo o 388mm 1 O08 08 O45 Ee 390mm 14 1 O06 O45 700mm 18 15 15 08 2 700mm 26 15 1 08 o 170mm 3 24 24 14 of 1190mm 41 24 16 13 my 550mm 15 1 1 06 By 550mm 2 12 08 06 3000mm 9 6 6 33 3000mm 107 59 43 38 oe 9500mm 2 9 9 106 Bag 5600mm 20 11 8 7 Aperture D 13 5 t0 17 10to13 5to7 Aperture D 135 to 17 10 to 13 depending on the objective distance Reference numbers Type Temperature range with with with with view finder view finder view finder view finder fixed optics fixed optics focusable optics fixed optics laser targeting light laser targeting light laser targeting light scanner type S 550 to 1400 C MB 14 3 839 100 3 839 110 3 839 120 3 839 130 600 to 1600 C MB 16 3 839 150 3 839 160 3 839 170 3 839 180 650 to 1800 C MB 18 3 839 200 3 839 210 3 839 220 3 839 230 750 to 2500 C MB 25 3 839 250 3 839 260 3 839 270 3 839 280 550 to 2000 C MB 20L 3 839 300 3 839 310 3 839 320 3 839 330 700 to 3500 C MB 35L 3 839 350 3 839 360 3 839 370 3 839 380 250 to 1000 C MB 10 3 839 600 3 839 610 3 839 620 3 839 630 300 to 1300 C MB 13 3 839 650 3 839 660 3 839 670 3 839 680 350 to 1800 C MB 18 3 839 700 3 839 710
3. 90 connector IMPAC pyrometers RS232 interface 3 820 830 connection cable length 20 m 90 connector 3 890 630 LDP 1224 LED display large 3 820 840 connection cable length 25 m 90 connector height of digits 57 mm 3 820 550 connection cable length 30 m 90 connector 3 835 060 AONE 3 820 750 connection cable length 5 m 90 connector 3 837 200 ees g late temperature resistant up to 200 C 3 837 230 i g P ket 3 821 120 additional cable for limit contacts 5 m PO ae l 3821130 additional cable for limit contacts 10 m AE OA 3821140 additional cable for limit contacts 15 m S DIRAN pee an tor TONN 3 821 150 additional cable for limit contacts 20 m 3 843 260 rotary mirror attachment ROT 10 IS 12 S IGA 12 S with integrated scanner The pyrometers IS 12 S and IGA 12 S with fixed optics are equipped with a scanning mechanism built into the pyrometer housing which moves the measuring beam up and down In combination with the pyrometer s maximum value storage peak picker the scanner is optimally used for scanning of thin oscillating wires for finding scale free spots on heavily scaled surfaces or for measuring small hot objects whose position is not exactly determined All instruments are equipped with a thru lens view finder and an ad ditional laser targeting light for exact alignment to the position of the measuring object The scanning angle is adjustable between 0 and 4 the scanning frequency between 4 and 10 Hz Dis
4. of measured value in C 1 C Exposure time tgo lt 1ms L temperature ranges with dynamical adaptation at low signal levels adjustable up to 10 s Emissivity 0 100 1 000 in 1 1000 steps Analog output linear 0 20 mA or 4 20 mA DC switchable load max 500 Ohm Test current output fixed 10 mA Power supply 24 V DC 15 to 40 V DC or 24 VAC 12 to 30 VAC 48 to 62 Hz Power consumption max 7 W Serial interface switchable at the pyrometer RS232 or RS485 addressable half duplex baud rate 2 4 up to 115 kBd Limit switches 2 relay outputs change over contacts switch power max 30 W Imax 1A Umax 60 V DC Control panel 4 keys operate with tipp of ball point pen Parameters adjustable at the instrument or via serial interface emissivity e response time tog clear time for maximum value storage tc subrange O to 20 or 4 to 20 mA switch points for limit switches C F interface RS232 or RS485 address baud rate test current output Additionally adjustable only via interface keyboard lock recalibration with special software Maximum value storage single or double storage cleared by preselected time interval external deletion contact or via digital interface automatically with the next measuring object Isolation power supply digital interface analog output are galvanically isolated against each other and housing Sighting built
5. 3 839 720 3 839 730 400 to 2300 C MB 23 3 839 750 3 839 760 3 839 770 3 839 780 250 to 1400 C MB 14L 3 839 800 3 839 810 3 839 820 3 839 830 IS 12 IGA 12 Ordering note When ordering please select one optics included in scope of delivery A connection cable or an additional cable for limit contacts is not included in scope of delivery Scope of delivery Pyrometer with optics of your selection InfraWin operating and analizing software Accessories works certificate user manual 3 846 610 exchangeable fixed optics 1 3 821 160 additional cable for limit contacts 25 m 3 846 620 exchangeable fixed optics 2 3 821 170 additional cable for limit contacts 30 m 3 846 630 exchangeable fixed optics 3 3 821 200 additional cable for limit contacts 5 m 3 846 640 exchangeable fixed optics 4 temperature resistant up to 200 C ia ah exc ranean E MKENOpUGS gt 3852290 Power supply NG DC for DIN rail mounting exchangeable fixed optics 6 3848670 exchangeable focusable optics 1 ee ee geable focusable optics am 3 890 640 LED digital display DA 4000 N Se ene eee ee 3 890650 LED digital display DA 4000 with 2 limit 3 848 690 exchangeable focusable optics 3 Ree ae l 3 820 340 connection cable length 5 m 90 connector 3 890 560 LED digital display DA 6000 N with possibility 3 820 530 connection cable length 10 m 90 connector for pyrometer parameter settings for digital 3 820 540 connection cable length 15 m
6. LUMASENSE TECHNOLOGIES IMPAC Infrared Thermometers Very robust high end IMPAC pyrometer for non contact temperature measurements on metals ceramics graphite etc between 250 and 3500 C IS 12 IS 12 S IGA 12 IGA 12 S e Temperature ranges between 250 and 3500 C e Short response times lt 1 ms e Extremely small spot sizes min 0 1 mm e Distance ratio up to 900 1 e Built in 5 digit LED display e Thru lens view finder or with additional laser targeting light e Test current output e 2 fast limit switches e Interfaces RS232 RS485 switchable e With fixed or focusable optics CE The IS 12 IS 12 S IGA 12 and IGA 12 S are very robust digital and highly accurate pyrometers for non contact temperature measurement on metals ceramics graphite etc For optimal match of the instrument to the application 6 different fixed optics and 3 different focusable op tics with extremely small spot sizes are available The pyrometer parameters can be selected via keys the settings are indicated on the built in LED display In measuring mode the actual tem perature is indicated The pyrometers are equipped with RS232 and RS485 serial interfaces switchable via the keys This addi tionally enables the reading of tem perature and pyrometer parameters via the provided nfraWin PC soft ware If necessary the parameters also can be changed via PC Two adjustable limit switches can be us
7. easuring distances is shown in the following table _ With fixed optics Measuring distance Scanning distance 54 mm 130 mm 144 mm 261 mm 554 mm 857 mm 1194 mm 1768 mm 5494 mm 8035 mm j O measuring distance 106 mm distance pyrometer s lens window ROT 10 me ai 4 AO Lol Renee t a mirror rotation scanning distance The signal is analysed via the pyrometer s analog output 0 4 20 mA and or the serial interface RS232 or RS485 The scanning frequency is permanently set to 12 5 Hz The attachment is powerd by 24 V AC 50 Hz The pyrometer has to be adjusted to the fastest exposure time due to the mirror rotation to keep the smallest spot size The high mirror rotation speed of the mirror produces spot sizes in form of a line For the different temperatur ranges MB the fol lowing spot sizes are achieved IS 12 MB 14 MB 16 18 20L_ MB 25 35L IGA 12 MB 10 MB 13 MB 14L MB 18 MB23 N fs JE SENN 2 1 x 0 7 2 0x 0 6 JE 18x04 1 6 x 0 2 144 mm 4 8x 1 0 46x08 4 3x0 5 4 1x0 3 954 mm 16 8 x 2 3 16 5 x 2 0 15 7 x 1 2 15 2 x 0 7 1194 mm 36 8 x 5 5 35 1 x 3 8 34 1 x 2 8 32 7 x 1 4 9494 mm C 1629x190 158 9 x 15 C 1589x 20 150 3 x 6 4 scanning angle pe til O Types with fixed optics Types with focusable optics optics inserted pulled out Overview Accessories
8. ed to trigger a switch process e g to recognize hot objects located in the measuring beam A thru lens view finder or addition ally a laser targeting light for exact alignment of the pyrometer is avail able The instruments IS 12 S and IGA 12 S are equipped with an inte grated scanner which moves the measuring beam adjustable up and down up to 4 Typical applications preheating annealing tempering welding forging hardening sintering melting soldering rolling brazing normalizing Technical Data IS 12 IS 12 S IGA 12 IGA 12 S Temperature ranges MB 14 550 to 1400 C MB 10 250 to 1000 C MB 16 600 to 1600 C MB 13 300 to 1300 C MB 18 650 to 1800 C MB 18 350 to 1800 C MB 25 750 to 2500 C MB 23 400 to 2300 C MB 20L 550 to 2000 C MB 14L 250 to 1400 C MB 35L 700 to 3500 C Subrange any range adjustable within the temperature range minimum span 51 C Spectral range LOr to Cium 1 45 to 1 8 um Signal processing fotoelectric current digitized immediately Accuracy below 1500 C 0 3 of measured value in C 1 C e 1 t 15 Tamb 23 C above 1500 C 0 5 of measured value in C Amb temp dependency tk lt 0 01 of reading in C x dT temperature of pyrometer housing 23 C Display built in 5 digit LED display additional function LED s Resolution interface and display 0 1 C analog output lt 0 025 of temperature range Repeatability 0 1
9. ents or the replacement of other pyrometers is simplified Output The analog measuring outputs 0 20 mA or 4 20 mA are selectable as well as the serial digital interfaces RS232 or RS485 Additionally the interface allows the controlling of the pyrometer via PC Bus control The serial interface RS485 facilitates the integration of the pyrometer into existing field bus systems Calibration If a suitable calibration source is available a calibration of the pyrometers can be done via serial interface without opening the housing C or F display active limit switches Fixed or focusable optics Laser targeting light optional LED display for measuring temperature or parameters Parameter indicator Adjusting keys for parameters interface RS232 or RS485 test current ouput Settings scanning angle scanning frequency only for the instuments IS 12 S and IGA 12 S Paralax free thru lens view finder Additional ouput for limit switches Power supply analog ouput digital interface ad The pyrometers are equipped with fixed or focusable optics The spot size for the fixed optics is shown for the specified measuring distance The focusable optics offer the smallest possible spot size at the required distance The spot sizes are shown in the follow ing tables all distances are measured from the front of the lens For spot sizes between those in the table values can be found by inte
10. in parallax free thru lens view finder additionally laser targeting light CAUTION power level lt 1 mW 630 680 nm CDRH class II Ambient temperature 0 to 70 C at housing no condensating conditions Storage temperature 20 to 70 C Rel humidity Non condensing conditions Protection class IP65 DIN 40 050 Weight 2 2 kg CE label according to EU directives about electromagnetic immunity LASER RADIATION DO NOT STARE INTO BEAM WAVELENGTH 630 680nm lt 1 mW MAXIMUM CLASS II LASER PRODUCT Advantages of the digital signal processing The signal processing of series 12 pyrometers is fully digital i e the detector signal is digitized immediately and digitally processed With this technique an extremely high accuracy and repeatability as well as very long measuring ranges are achieved Accuracy The high accuracy will be achieved by the digital linearisation of the sensor output as well as the digital com pensation of the ambient temperature Temperature range Due to the digital technique the user can set any temperature sub range within the full temperature range The minimum span of the sub range is 51 C The analog measuring output corresponds automatically to the selected sub range This setting of a sub range can be done without recalibration of the pyrometer and does not effect the high accuracy and repeatability As almost any sub range is adjustable the storage of spare in strum
11. rpolation The optics can be changed at any time to another of the same type without recalibrating the pyrometer The selection of a suitable optics depends on different factors e Very short measuring distances up to 250 mm to achieve extremely small spot sizes are only available as fixed optics e The rotary mirror attachment ROT 10 can only be used in combination with fixed optics e The 3 focusable optics allow the exact adjustment of any required measuring distance from 277 mm e Focusable optics offer high flexibility to adapt the instrument to applications with different measuring distances Fixed optics 12 S IGA 12 IGA12 Spot sized differing from the stated values IS 12 IS 12 S MB MB 1 18 20L MB 25 35L can be calculated with the following equa IGA 12 IGA 12 S MB10 MB13 14L MB18 MB23_ uong ptics Meas distance Spot size Mg mm yy a 80mm 0 9 0 7 0 3 0 1 2 a 160mm 0 7 0 6 0 4 0 2 3 a 250mm 1 0 8 0 5 0 3 4 a 660 mm 23 2 1 2 0 7 a 1300 mm 5 5 3 8 2 8 q 4 6 a 5600 mm 19 15 12 6 4 Aperture D 19 13 5 10 T M T M D D M M D D hle o otics IC 4 2 Foci ica b aC pti cs IGA TA Measuring Spot size Mg mm Measuring pot size Mg mm distance MB 14 MB16 MB18 MB25 distance MB 10 MB13 MB18 MB23 a mm MB 20L MB 35L a mm MB 14L WE 27mm 09 06 06 04 W 279mm 13 09 05 04 S 400mm 1
12. tance a Scanning distance at 4 scanning angle a 80mm 5 6 mm a 160mm 11 2 mm a 250 mm 17 5 mm a 660 mm 46 mm a 1300 mm 91 mm a 5600 mm 391 mm scanning distance The moving measuring beam does not increase the spot sizes due to the very fast exposure time of the pyrometers The scanning length increases with increasing measuring distance An overview of the scanning length at the different distances of the optics is shown in the table Rotary mirror attachment ROT 10 accessory For larger scanning distances than the integrated scanner the ro tary mirror attachment ROT 10 can be mounted on the IS 12 and IGA 12 with fixed optics So a scanning angle between 63 and 73 can be achieved depending on the measuring range Typical applications of the rotary mirror attachment are measure ments of thin oscillating wires or moving sheets and capturing the maximum temperature of bulk material or scaled metals With help of a rotating mirror the measuring beam of the pyrometer is moved over the measuring object in a line If the instrument is equipped with a laser targeting light the scanning distance can be followed visually The rotary mirror attachment only can be mounted onto the fixed optics pyrometers The distance of the pyrometer s lens to the win dow of the scanner is 106 mm The required optic has to be selected accordingly An overview of the scanning distances of the different m