Physio Range User Manual
Contents
1. prevention of deep vein thrombosis ARTERIAL Raynaud s disease arteriosclerosis acro cyanosis blue leg EDEMA Gravitational lymphatic post mastectomy inguinal lymphadenectomy after cast removal rheumatoid multiple sclerosis FLEXION Chronic injury burns and skin graft CONTRACTURES CONTRA INDICATIONS Acute thrombophlebitis acute pulmonary edema congestive heart failure known or suspected deep vein thrombosis PULSEPRESS DYVAMIC COMPRESSION THERAPY Ef 6UISH TECCHUICAL SPECIFIC TIONS Power Source Frequency Internal Fuse Caution A Water Resistance Mode Storage Operation Pressure Regulation Pressure Meter 220 250V AC 50Hz T500mA Type BF Equipment not suitable for use in the presence of Flammable Anesthic mixture with air or oxygen or nitrous oxide Read instructions prior to using equipment Ordinary Equipment Intermittent Operation Equipment to be stored used between 20 and 30 degrees C Equipment suitable for use 0 50 humidity Range 30 60 100mmHg 5mmHg LCD Display Range 0 100mmHg 2mmHg The following data applies to Physio 3 Physio 3 Pro Physio 6 Power Consumption D 20W Class II Double Insulated Device The following data applies to the Physio 12 Pro Power Comsumption D PULSEPRESS DYVAMIC COMPRESSION THERAPY 40W Class Double Insulated Device
2. OM TROLS 1 Power Switch This turns the unit on and off The unit starts cycling as soon as power in turned on 2 Pressure Display This displays the pressure set by the user When the set pressure is reached in the garment the compres sor switches off and waits for the cycle time to complete prior to deflating the garment When this happens Ommhg is displayed 3 Air Outlet This is where the air tube is attached For use with a single garment the top bung must be in place Remove the bung for use with two garments 4 Power Inlet This is where the power cable is plugged 5 Pressure Control This sets the air pressure in the garments to that stated on the pressure display from 30 100mmHg 6 Deflate Timer Control This sets the deflation time cycle in seconds 7 Inflate Timer Control This sets the inflation time cycle in seconds Auto mode sets the inflation and deflation setting to the optimal for the garment Just select a pressure and the rest is done by the internal microprocessor 8 Therapy Control This sets the therapy time in minutes The black start button needs to be pushed to start the unit Once complete the unit bleeps and vents 9 Start button Press this to start the unit running Once se lected therapy time is completed press this to restart the system E UEBLISI I OPERA THUG IUSTRUC TIO US WARNING These units must only be operated by gualified medical staff Operation of these units by any ot
3. PULSEPRESS DSTUAITNC COMPRESSION THERAPY UT a A CONU TENU TS ENGLISH SAFETY INSTRUCTIONS ELECTROMAGNETIC INTERFERENCE DESCRIPTION OF CONTROLS CARE AND MAINTENANCE INDICATIONS AND CONTRA INDICATIONS TECHNICAL SPECIFICATIONS FRANCAIS INSTRUCTIONS DE SECURITE INTERFERENCE ELECTROMAGNETIQUE DESCRIPTION DES COMMANDES ENTRETIEN ET MAINTENANCE INDICATIONS ET CONTRE INDICATIONS SPECIFICATIONS TECHNIQUES DEUTSCH SICHERHEITSHINWEISE ELEKTROMAGNETISCHE STORUNG BESCHREIBUNG DER STEUERELEMENTE PFLEGE UND WARTUNG ANZEIGEN UND GEGENANZEIGEN TECHNISCHE DATEN ITALIANO ISTRUZIONI DI SICUREZZA INTERFERENZA ELETTROMAGNETICA DESCRIZIONE DEI COMANDI CURA E MANUTENZIONE INDICAZIONI E CONTROINDICAZIONI SPECIFICHE TECNICHE PORTUGUESE INSTRU ES DE SEGURAN A INTERFERENCIA ELECTROMAGNETICA DESCRICAO DOS CONTROLOS CUIDADOS E MANUTEN O INDICACOES E CONTRA INDICACOES ESPECIFICACOES TECNICAS ESPANOL INSTRUCCIONES DE SEGURIDAD INTERFERENCIA ELECTROMAGNETICA DESCRIPCION DE LOS MANDOS CUIDADO Y MANTENIMIENTO INDICACIONES Y CONTRAINDICACIONES ESPECIFICACIONES TECNICAS PULSEPRESS DYNAMIC COMPRESSION THERAPY EU Hy a SAFETY IUSTRUC TIOMNMS Read all of these instructions and save them for later reference Follow all warnings and instructions marked on the devices These units m
4. her person is entirely the responsibility of that person WARNING This manual must be read and fully understood before these units are applied to patients WARNING Refer to section on indications and contra indications prior to the unit being applied to patients Application to Patient These units are designed to provide compression to the Pulse Press range of Solo and Multi pressure garments Each unit can be connected to one or two garments simultaneously If only one garment is being used then the other outlet is sealed For the Multi pumps the blanking plug must be removed to use a second garment The hoses connection is unable to be the wrong way round The other end of the air feed hose simply pushes onto the garment For the Solo pumps the hose latches into the outlet with a push and twist action The other end of the air feed hose pushes into the garment inlet elbow Operational Use 1 oe nah 2 Connect the mains lead to the IEC power inlet socket Insert the mains plug of the lead into a standard 220 240 V mains socket Fit the air feed hose s to the air outlets as described above Ensure that all connections to the pump and garment make a good seal Place fit the garment s onto the limb s requiring treatment Turn the unit on A visual mains indicator will illuminate Select the required pressure using the pressure control Set up the inflate and deflate times as required Note the time the treatment start
5. ment at all times in the cycle 3 Deflate Timer Control This sets the deflation time cycle in seconds 4 Air Outlet This is where the air tube is attached The unused air outlet is plugged Unplug for second garment 5 Power Inlet This is where the power cable is plugged 6 Power Switch This turns the unit on and off The unit starts cycling as soon as power in turned on 7 Inflate Timer Control This sets the inflation time cycle in seconds NB if the inflate time is set too low then the system will not have time to reach the desired pressure PHYSIO 6 COM TROLS 1 Power Switch This turns the unit on and off The unit starts cycling as soon as power in turned on 2 Pressure Display This displays the pressure set by the user When the set pressure is reached in the garment the compres sor switches off and waits for the cycle time to complete prior to deflating the garment When this happens Ommhg is displayed 3 Air Outlet This is where the air tube is attached For use with a single garment the top bung must be in place Remove the bung for use with two garments 4 Power Inlet This is where the power cable is plugged 5 Pressure Control This sets the air pressure in the garments to that stated on the pressure display from 30 100mmHg 6 Deflate Timer Control This sets the deflation time cycle in seconds 7 Inflate Timer Control This sets the inflation time cycle in seconds PHYSIO e PRO C
6. s so that the unit can be switched off when the desired time has elapsed DO NOT unzip the garment when the unit is switched on This may cause damage to the garment Always turn off the power before unzipping the garment Extra comfort can be obtained by first placing a Pulse Press Garment Liner on the limb under the pressure garment PULSEPRESS DYNAMIC COMPRESSION THERAPY E a CARE AMD MAIU TEMAUCE PUMP Before cleaning the pump unit always ensure it has been disconnected from the mains power supply Clean the unit with a light detergent ensuring that only a damp and not wet cloth is used If in doubt as to the action of the detergent try cleaning the underside of the unit first where damage will be unseen There are no service items which need replacing or cleaning out on a regular basis All technical information can be found at www mjsgrp com GARMENT The garments can be sponged with a detergent Allow to dry fully before use DO NOT FORCE DRY In the event of heavy soiling the garments can be machine washed See wash label Always insert the air entry blanking plug to prevent water ingress and turn the garment inside out prior to machine washing IUDICA TIOMS AMD COM TRA IFUDICA TIOMS INDICATIONS VENOUS Post phlebetic syndrome varicose veins varicosities of pregnancy stasis dermatitis leg ulcers WOUND RECOVERY Venous ligation or stripping hand surgery total knee replacement D V T For
7. se interference to radio communications If this equipment does cause interference then the user is encouraged to try to correct the interference by one or more of the following measures e Re orientate or relocate the receiving antenna e Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the manufacturer of the device PULSEPRESS DYNAMIC COMPRESSION THERAPY PHYSIO 3 COM TROLS 1 Pressure Control This sets the air pressure in the garments to that stated on the front panel in mmHg 20 60 mmHg 2 Air Outlet This is where the garment air tube is attached 3 Power Switch This turns the unit on and off The unit starts cycling as soon as power in turned on The system automatically sets the inflation to that needed by the garment being used Once the pressure in the garnent hits the set pressure the system deflates for a fixed time period 4 Power Inlet This is where the power cable is plugged in PHYSIO 3 PRO COM TROLS 1 Pressure Control This sets the air pressure in the garments To set the pressure attach a garment and set the inflation to 120 secs Switch the pump on and wait for the pressure meter reading to settle on a number Now adjust the pressure clockwise to increase to the desired level giving the system time to settle 2 Pressure Meter This displays the pressure in the gar
8. ust only be operated by qualified medical staff Operation of these units by any other person is entirely the responsibility of that person This manual must be read and fully understood before these units are applied to patients e Equipment not suitable for use in the presence of Flammable Anesthic mixture with air or with oxygen or nitrous oxide Unplug the pumps before cleaning Only ever use a damp cloth Do not spill liquid onto the pump enclosure e Always place pumps on a flat stable surface before operation The pumps will not operate properly if tilted or at an angle Do not cover the pumps whilst in operation e Use only the type of power source indicated on the pump s rear label e Do not use a damaged or frayed power cord Unplug the pumps and refer servicing to qualified personnel under the following conditions o Ifthe power cord or plug is damaged o If liquid has entered the pumps o If the plastic outer enclosure is damaged o If the pump is not operating normally continuous running noisy running or low performance e Always switch off the pump before unzipping the garments ELECTROMAGUETIC IU TERFEREUCE This equipment has been constructed and tested to comply with EN60601 1 2 EMC regulations for Medical devices This test was designed to provide reasonable protection against harmful interference This equipment may generate and radiate radio frequency energy and if not installed correctly may cau