Home

klearbar mini countertop water dispenser

image

Contents

1.
2. filter If you see unflushed carbon fines these may appear as black specks in the water and are not harmful but may not present well so consider additional flushing after inserting the new filter It is also suggested to sanitize both the hot and cold tanks similar to the new install procedure every other filter change 12 months as needed Turn counter clockwise left then lift to remove Insert new filter then turn clockwise right to install Changing the UV Lamp Your Klearbar Mini pure water dispenser may come equipped with an optional ultraviolet UV light that will reduce up to 99 9 of unknown and potentially harmful bacteria or other microbes When operating the UV lamp resides safely inside a protective quartz sleeve and stainless steel chamber strategically located between the water reservoir and faucet The UV is not designed for use when known non potable water conditions are present Discontinue use of the Klearbar Mini during these conditions and thoroughly flush and change the filter prior to renewed use 1 Turn off power and unplug the Klearbar Mini you do not have to turn off water for this procedure Remove the top black cover Use the UV removal tool to press the red tab on top of the UV lamp component in an outward direction and then twist the UV component in a counter clockwise manner to unlock Lift the UV lamp straight up to remove DO NOT REMOVE AT AN ANGLE FOR DANGER OF BREAKING CALL YOUR INSTALLE
3. minimize stress on stainless water tank and optional UV component Flush with clean tap water thoroughly after a one hour soak New Installation 1 Remove all packing materials before performing procedures below 2 Make sure both hot and cold switches are in the off position 3 Pre mix 5 quarts of very hot or near boiling tap water to any of the following a OPTIONAL Sodium bicarbonate baking soda 8 tablespoons 4 oz b OPTIONAL Household bleach 1 ounce WARNING IF USING BLEACH BE MINDFUL OF POTENTIAL STAINING OF CLOTHES FS PILLED WARNING IF USING OPTIONAL SANITIZER WITH KLEARBAR MINI2 ONLY DISCONNECT UV LAMP COMPONENT BEFORE ADDING SOLUTION TO PREVENT POTENTIAL OF BAD AFTERTASTE KLEARBAR MINI2 WILL NOT LEAK WHEN REMOVING THE UV LAMP AVOID TOUCHING UV LAMP WITH BARE FINGERS TO PREVENT NATURAL OIL TRANSFER ONTO LAMP WHICH MAY DECREASE LAMP LIFE REINSERT UV LAMP WHEN FLUSHING IS COMPLETE 4 Plug Mini into GFCI electrical outlet 5 Remove top reservoir cover and slowly pour sanitizing solution into top of empty reservoir 6 Dispense from both hot and cold water sides to fill internal lines with solution 7 Soak for 1 3 hours dispense ALL water from both sides to flush fill again with clean tap water dispense from both sides to rinse NOTE ANOTHER DRAINING METHOD IS TO REMOVE SILICON PLUGS FROM BOTTOM OF KLEARBAR MINI REMEMBER TO REPLACE BEFORE REFILLING Between Filter Changes 1 Turn off water supply to the Kle
4. reservoir float Immediately turn off water Klearbar Mini beeps switch has engaged indicating supply and call for service possible overflow Hot water switch is turned off Verify the hot water switch is turned on Energy Save mode has activated Touch any button to wake up Klearbar Mini then wait several Hot water mode does not minutes and try again produce enough hot water or 1 1 1 1 i Excessive hot water demand Wait five minutes and try again does not dispense at all Internal overload breaker has Immediately turn off entire tripped possibly due to no system turn off water supply water in hot tank when hot tank and call for service turned on Cold water switch is turned off Verify the cold water switch is turned on Energy Save mode has activated Touch any button to wake up Cold water mode does not the Klearbar Mini then wait produce enough cold water several minutes and try again Excessive cold water demand Wait several minutes and try again Water in dispensing lines have Pour the first cup of water out warmed to room temperature and dispense again Water has a non acceptable New Klearbar Mini Sanitize and or flush taste New Klearbar Filter is several months old Replace filter sanitize and flush Pour out the first cup or two of water daily as needed Discarded water is still safe for drinking plants or other uses Service Provider 21 Serial Klearbar 855 GO KLEAR www klearbar com
5. 1 4 tubing into 1 4 union tee inserted into refrigerator water feed line 1 4 union tee 1 4 stem elbow 08 Connect To Existing Refrigerator Ice Maker Water Line E use the included 1 4 union tee when connectingto a 1 4 J water mains connection or use a brass compression 2 7 union tee If desired always use a plastic compression W ferrule when connecting polyethylene tubing using a brass 5 union a brass compression ferrule may cut into the plastic tubing and cause a leak 1 BEFORE PLUGGING IN TO ELECTRICITY turn off water line supply to refrigerator ice maker 2 Using a plastic tube or copper line cutter make a square cut of the existing ice maker water line no closer than 12 inches from where the water line originates from the floor or wall and insert the 1 4 union tee here It may be good to have a large towel nearby as a small amount of residual water may spray and drain out once the line is cut Connect one end of the included 1 4 polyethylene tubing to the 1 4 union tee 3 Place the Klearbar Mini within a few feet of an available GFCI electrical socket and connect the included 1 4 stem elbow into the water inlet port on the back of the unit be careful not to connect to the optional overflow port Now connect the opposite end 1 4 polyethylene water line into the 1 4 elbow behind the Klearbar Mini Trim off extra water line as needed for a professional look 09 4 Install an optional 1 4 turn ball
6. KLEARBAR MINI COUNTERTOP WATER DISPENSER INSTALLATION USER MANUAL M KLEARBAR TAP INTO MORE TAP INTO MORE Dear customer We know you have multiple options and thank you for choosing the best KlearBar For home and office Clearly the right call anytime Index OEA diagram nn 06 ce a 07 Use la lq e nn yz EAE 000 313 6 specifications ass 18 65 0011 18 oaoa 20 WHAT S YOUR FAVORITE COLOR Blue bar Orange bar Silver bar Red bar Green bar Yellow bar White bar Black bar Cream bar si SmartFilter N 01 Water j Quality m al BIRIMPEMIPED amp PURE 06 Overview amp Diagram 1 Touchscreen operation panel 2 Front panel indicator light Blue COLD water Red HOT water Purple ENERGY SAVE mode Energy save mode will start after 4 hours of non use Touch any key to bring system to normal operation 3 Fali el 4 Removable drip trav 5 Removable top panel 6 On Off cold water compressor and deliverv pump 7 On Off hot water tank 8 Water overflow line outlet 9 Water line inlet insert included 1 4 stem Touch screen instructions user guide 1 Hot water activation icon 2 Tank refill activation icon 3 Cold water activation icon 4 UV light activation icon Mini2 only For HOT water dispense touch and release 5 t
7. R OR KLEARBAR IF THIS SHOULD HAPPEN 2 Be careful not to touch the new UV lamp glass as natural oil from your fingers may cause reduced UV lamp effectiveness Insert the new UV lamp and line up top tab where indicated then twist clockwise while gently pressing down until you hear a click indicating the lamp is properly inserted 3 Reinstall top cover plug unit back in and turn on If the UV icon on the top operational panel is flashing the lamp may not be properly inserted Repeat procedure as needed A Discard old UV lamp properly UV lamps contain mercury Hg and should be disposed of in accordance with local disposal laws Contact www lamprecycle org or your local recycler for details J UV removal tool UV replacement Included with lamp Part install kit 4UVGR310MB Cleaning Your Klearbar Mini Using amicrofiber or soft cloth dampened with warm water you can wipe your Klearbar Mini s outer panels Do not use harsh detergents or other cleaning aids which can possibly damage the outer surface Use only a dry cloth to wipe the touch screen Do not use water or any other detergent to clean the back of the machine Keep dry Your Klearbar Mini color side panels are easily changeable with a Phillips head screwdriver Remove the top black cover Locate the two screws on both the front and back top corners of each side panel Loosen both screws for each panel e Facing either panel position your thu
8. arbar Mini 2 Turn off both hot and cold switches 3 Pre mix 5 quarts of very hot or near boiling tap water to any of the following a OPTIONAL Sodium bicarbonate baking soda 8 tablespoons 4 oz b OPTIONAL Household bleach 1 ounce WARNING IF USING BLEACH BE MINDFUL OF POTENTIAL STAINING OF CLOTHES SPILLED WARNING IF USING OPTIONAL SANITIZER WITH KLEARBAR MINI2 ONLY DISCONNECT UV LAMP COMPONENT BEFORE ADDING SOLUTION TO PREVENT POTENTIAL OF BAD AFTERTASTE KLEARBAR MINI2 WILL NOT LEAK WHEN REMOVING THE UV LAMP AVOID TOUCHING UV LAMP WITH BARE FINGERS TO PREVENT NATURAL OIL TRANSFER ONTO LAMP WHICH MAY DECREASE LAMP LIFE REINSERT UV LAMP WHEN FLUSHING IS COMPLETE 4 Fully drain both hot and cold sides of reservoir 5 Remove top reservoir cover and slowly pour sanitizing solution into top of reservoir Hot tank will fill first then cold ambient reservoir 6 Dispense from both hot and cold water sides to fill internal lines with solution 7 Soak for 1 3 hours dispense ALL water from both sides fill again with clean tap water dispense from both sides 1 Changing the Water Filter 1 Lift top black cover back to front to remove Turn off water supply then turn filter in a half turn counterclockwise and pull up Insert new filter and turn clockwise to fully engage back into unit 2 Turn water supply back on and dispense at least three 3 gallons of cold water This procedure will drain old water and flush new
9. enses near 40 cups of cold water an hour 2 0 gallons 7 6 liters at an average temperature of 50 degree F 10 degree C e R134 refrigerant 1 5873 oz e 33 ounce 1 0 liter ambient water capacity above cold water baffle 86 ounce 3 2 liter total main tank capacity UV ultra violet lamp Klearbar Mini2 model only Klearbar replacement bulb assembly part 4UVGR310MB e Lamp type T5 germicidal e 4 W 0 17 A 29V e replace every 6 12 months Purification and Filtration Systems 300 gallon 1 micron carbon block filter Klearbar Smart filter part 37MC235 e NSF 42 53 certified Replace a minimum of every six months Water Supply e Minimum water pressure 22 psi Maximum water pressure 87 psi Product Dimensions e 15L x 12 5W x 14 5H 30 Ibs weight 20 Trouble Shooting PROBLEM REASONS FOR MALFUNCTION SOLUTIONS No electrical outlet connection Plug in electrical cord No water source connection Verify connection to water line and valve is turned on Water is not dispensing No power at electrical outlet Reset GFCI or breaker Filter is missing or clogged Verify filter is properly seated into filter head into filter head or replace filter Water line not connected Immediately turn off water properly supply and reconnect Water leakage Leakage from within the Mini Immediately turn off water supply call for service Overflowing drip tray Remove and empty drip tray EAS Al Emergency
10. hen touch and hold 6 For COLD water dispense touch and hold 7 07 Installation amp Maintenance Your Klearbar Mini comes standard with virtually everything you need for a simple water line connection Installation User manual 15 feet of food grade 1 4 polyethylene tubing 45 psi pressure reducer pre installed inside water dispenser Angle stop valve mains connector 1 4 union tee install if using existing ice maker water line connection 1 4 stem elbow install at water line inlet You may also need the following items to assist your installation Adjustable wrench to install angle stop valve Teflon plumbers tape use when installing angle stop valve e Plastic tubing cutter or scissors 3 8 inch drill bit and drill if needed to drill hole in cabinetry to hide water line ALWAYS PLUG KLEARBAR MINI ELECTRICAL CORD INTO A 6 PROTECTED POWER OUTLET There are multiple ways to connect your Klearbar Mini but regardless of your choice it is recommended to follow local plumbing codes or consider hiring a licensed plumber But should you decide to DIY do it yourself we have provided a basic blueprint to get you on your way Perhaps the easiest connection is to an existing water line already provided by your refrigerator ice maker Use a 1 4 union tee for this connection a r M Connect 1 4 tubing into 1 4 stem elbow Connect 1 4 stem elbow into water line inlet port b f Connect
11. mbs half way down near the edge of both sides left thumb on the left side and right thumb on the right side e Press and slide in a downward motion which should unlatch the panel from the inside allowing you to remove Do this for both sides Install the new panels in reverse and you re done REPLACEMENT COLOR PANELS 2 PER SET Blue part MINIP BLU Red part MINIP RED White part MNIP WHT Orange part MINIP ORG Green part MINIP GRN Black part MINIP BLK Silver part MINIP SLV Yellow part MINIP VEE Cream part MINIP CRM Safety Instructions Do not use extension cords or power adaptors to avoid overheating and potential fire hazards e Only connect the Klearbar Mini to a GFCI grounded power source Do not use If there Is a defect in either the electrical cable power source or any other part of the Klearbar Mini Call you vendor for assistance on any questions related to these issues e Do not let children operate the Klearbar Mini unattended by an adult The Klearbar Mini can dispense extremely hot water which can cause severe burns if handled inappropriately To avoid water damage and overflowing do not reposition the Klearbar Mini prior to first shutting off the water inlet and then emptying both internal hot and cold water tanks The Klearbar Mini is intended to purifying and filtering drinking water as provided to purify a
12. n tape to downstream thread and reconnect the riser tube existing waterline existing waterline Y kk 5 faucet r li fi existing waterline J E gt to faucet 1 JS l 1 epvernecrerceorenace 7 RE 0 SSS m asa MATT 7 TTIIIIIYT DILL PASS SRSA SSE ASSURED 7 i p L 77 7 aa 7 1 l 1 J J wen se 1 fin Y gt bar a 7 A tee jA L quick tee supply stop 2 Supply stop adapter B gt supply stop adapter Before tee adaptor Tee adaptor installec After tee adaptor installed 4 Use the included 1 4 polyethylene tubing and connect to the Klearbar angle stop valve or optional tee adaptor First slide nut then compression ring onto tubing and then insert tubing insert into end of plastic tube Now attach plastic tubing to Teflon taped thread 5 Next drill a 3 8 hole through sink or countertop near the final resting place of the Klearbar Mini Be extremely careful if drilling through a porcelain cast iron sink or granite countertop as damage may result Consult a professional if unsure with this procedure Also consider drilling hole s behind cabinet drawers leading to side opening of cabinet versus top opening of countertop 6 Place the Klearbar Mini within a few feet of an available GFCI electrical socket and connect the included 1 4 stem elbow into the water inlet port on the back of the unit be careful not to connect to the optional overflow port Now pull the 1 4 water line through the drilled hole
13. nd filter NSF standards In case there is an official recommendation by the public health authority to boil water prior to drinking tap water in your area do not use the Klearbar Mini The Klearbar Mini is intended for use with approved potable water only Replace the filter sanitize and thoroughly flush the Klearbar Mini immediately after boil water advisory has lifted e Leave a minimum two inch space on all sides of the Klearbar Mini for proper venting and operation of the cooling and heating systems If you do not intend to use your Klearbar Mini for several days for safety purposes unplug it and close the incoming water supply line into the machine When the machine is turned back on it is recommended to flush and sanitize both tanks as described above e Klearbar Inc will not be responsible for any internal changes to the Klearbar Mini made by an unauthorized installer as well as for any defect malfunction or damage caused by the use of non original replacement parts e Servicing and repairs should solely be handled by an authorized dealer and any warranty is limited to original parts only from an authorized dealer of Klearbar Inc Technical Specifications Electricity e 120v 7 e 115 e 7 5 Amps Heating System 53 ounce 1 6 liter capacity dispenses up to 40 cups of hot water an hour 2 2 gallons 8 2 liters at an average temperature of 185 F 85 C Cooling System 73 ounce 2 2 liter capacity disp
14. s and connect into the 1 4 stem elbow at rear of Klearbar Mini 7 Install an optional 1 4 turn ball valve not included available at most hardware stores about 12 inches from the 1 4 stem elbow enabling easy on off access This is very convenient should you ever need to remove the Klearbar Mini for cleaning or should you discover a leak 8 Turn on mains valve and check for leaks 9 MAKE SURE THE HOT WATER SWITCH IS IN THE OFF POSITION BEFORE PLUGGING IN to a GFCI receptacle Allow to completely fill Once full the Klearbar Mini will automatically stop filling with water 10 Dispense at least 10 ounces of water from both the hot and cold tanks It is now safe to turn on the hot and cold water tanks WARNING TURNING ON THE HOT WATER TANK BEFORE COMPLETELY FULL MAY RESULT IN TRIPPING THE HOT TANK OVERLOAD PROTECTOR SWITCH WATER WILL NOT HEAT IF THIS HAPPENS TURN OFF WATER CONNECTION UNPLUG UNIT AND CONTACT YOUR SERVICING DEALER FOR ASSISTANCE AN UNEIMITRED SUP BLT OF PURE GREAT TASTING CLEAN WATER ET La th en a 1 EA LL E1 eF AS User Maintenance It is recommended to flush and sanitize your Klearbar Mini upon installation and after a filter change approximately every six months or as needed to assure the freshest drinking water possible Use a 5 quart pre mixed solution of very hot tap water and OPTIONAL sanitizer baking soda works good using bleach avoid prolonged periods of use to
15. valve not included available at most hardware stores about 12 inches from the 1 4 stem elbow enabling easy water on off access without having to pull the refrigerator away from the wall This is very convenient should you ever need to remove the Klearbar Mini for cleaning or should you discover a leak 5 BEFORE TURNING ON WATER LIFT RESERVOIR COVER THEN REMOVE MOISTURE ABSORBING DESICCANT BAG INSIDE RESRVOIR ALSO REMOVE PROTECTIVE FOAM INSERTS 3 FROM THE ELECTRONIC FLOAT SWITCH KLEARBAR MINI2 ONLY INSIDE THE RESERVOIR 6 BEFORE TURNING ON WATER PLACE HOT WATER SWITCH TO OFF POSITION and then plug the Klearbar Mini into a GFCI receptacle Open the water connection and allow to reservoir to fill up When the reservoir is full prime the water pump by dispensing 10 ounces of water from both the cold and hot water tanks Only after priming 5 it now safe to turn on the cold and hot water switches on the rear of the equipment Connect To Main beneath a Sink 1 Turn off COLD water supply beneath sink 2 Use a wrench and disconnect the copper or braided riser tube connected to the stop valve already threaded or soldered to the copper water main 3 Thread the Klearbar angle stop valve mains connector OR OPTIONAL TEE ADAPTOR purchased separately by first wrapping Teflon tape not included around the newly exposed thread of the stop valve plumbed to the cold water main Hand tighten then snugly tighten using a wrench Then apply Teflo

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Secadora DV203AGW Manual de Usuario  Entfeuchter Kibernetik M20  Quick Start Guide – TurboVisualStudio  Image for Linux User Manual  iアプリ/iウィジェット  0051~0100(PDF:1175KB)  LÁMINAS ATRAPAINSECTOS  002202512 LUCREZIA LP14 LP20 LP30 002202512  postgres tutorial-7.3.2-A4  Emerson CF3900 Apollo Brushed Steel Ceiling Fan  