1. distance d a A is side view object sizes eiltan ceb top view Before connecting the devices adapt the whole scanner setup to the size ofthe object or surface region you want to scan The intersection angle between projection and camera view should be around 20 25 max 15 35 The following table should give you some indications for an optimal setup A A Te Lens distance b Distance d Achievable scan Size of scan object Calibration 7 surface region s pattern between camera between scanner resolution approx and projector and object 0 2 of object size lt 30 mm 30mm ca 30 mm ca 90 mm lt 0 1 mm 50 mm 60 mm ca 40 mm ca 120 mm ca 0 1 mm 70 mm 60 mm ca 65 mm ca 180 mm ca 0 15 mm 90 mm 120 mm ca 80 mm ca 220 mm ca 0 2 mm 120 mm 120 mm ca 110 mm ca 300 mm ca 0 25 mm 150 mm 120 mm ca 125 mm ca 350 mm ca 0 3 mm 200 mm 240 mm ca 160 mm ca 450 mm ca 0 4mm 300 mm 240 mm ca 250 mm ca 700 mm ca 0 6 mm 500 mm 240 mm ca 400 mm ca 1200 mm ca 1 0 mm in general similar to object angle 20 25 object should fill ca 0 2 of object size between them camera image The camera can be mounted left or right of the projector depending on how a suitable distance between their lenses can be achieved The DAVID software also supports a vertical setup with camera and projector above each other Installation Conne
2. Decrease aperture size The Projector Brightness control should be at maximum in most cases Only reduce it if a clean undistorted sine wave cannot be obtained otherwise 9 Look at the projected grey planes in the camera image Adjust camera focus mechanic focus ring so that the object is depicted as sharp as possible Also you can use the projected black and white stripes for focussing 10 Fasten all screws projector ball joint of camera so that nothing can be dislocated from now on 2 Menu Camera Calibration 1 Select a calibration pattern size which fits to the object see table on page 3 Set up the calibration corner at precisely 90 using the mounting tracks For starters the pattern should be flapped to the inside while advanced users may be able to reduce reflections with a concave corner setup 2 Remove the object and set up the scanner and the calibration corner in front of each other with approx the same distance as the object before The projection and camera image should be well focused The camera image must show at least the 6 ring markers and a few dot markers The whole camera image should be filled with around 15 to 70 calibration markers and the camera should not able to look past the calibration boards You can move rotate and tilt the scanner as a whole but you should not change anything above the red mounting rack Enter the scale size of the calibration pattern at Calibr Scal
3. DAVID SLS 1 Getting Started Guide Version 3 4 DAVID Vision Systems GmbH Rudolf Diesel Str 2a D 56070 Koblenz Germany Phone 49 0 261 983 497 70 Fax 49 0 261 983 497 77 Mail service david vision systems de Web www david laserscanner com 2012 DAVID Vision Systems GmbH DAVID SLS 1 Contents of Package SL Scanner pre mounted consisting of e Video projector e Camera with focusable lens e Mounting rack with ball joint for camera Tripod with protective bag 2 calibration panels with 2 mounting tracks 90 USB drive with DAVID Laserscanner Pro Edition and camera drivers Accessories for projector External wall power supply e Remote control e VGA cable e HDMI cable e 2 AN cables not required for scanner e Protective bag e User Manual Adapter set for global power supply USB cable for camera Cable straps System Requirements Windows XP Vista or 7 32 bit or 64 bit 3D graphics adapter Available VGA or HDMI port Two available USB ports Recommended Dual core processor 2 GHz 4 GB RAM NVIDIA or AMD graphics adapter Safety Instructions Only operate the scanner in a dry environment Do not operate the scanner in areas where there is a risk of explosion Repairs to the scanner or its components may only be performed by an authorized service centre or the DAVID Laserscanner after sales service Do not make changes of any kind to your scanner Preparation Setup
4. be carried out in the following order 1 Menu Hardware Setup Adjustment and settings of projector and camera 1 Select setup type Structured Light Setup 2 Choose the correct Screen ID such that the stripe pattern is projected by the projector 3 Place the scanner in front of the scanned object and adjust the projector s position and direction so that its projection illuminates the scanned surface not less but also not much more 4 Use the projector s focus ring to adjust sharpness such that the black and white stripes are well focused on the object surface 5 Below Camera select your camera DAVID CAM 2 M You will see the live view If necessary roughly adjust the camera s mechanic aperture and focus ring 6 Aim the camera so that it can see the projected pattern on the object Then fix the ball joint 7 The Exposure Time should be set to 1 60s otherwise the camera image might flicker or pulse when looking at the projection 8 Adjust the mechanic aperture at the camera s lens Regard only those image regions that show the circular wave pattern The red intensity curves must be sinusoidal and must not be over or under saturated In other words the red sine curve must not be cut off at the blue borders ESN WINS MU Bu a Sar Sc 1b EI Too dark Perfectly adjusted Too bright Increase aperture size sine wave nearly reaches the Sine wave is cut off overdriven blue borders
5. ct all components as depicted below VGA HDMI Installation of the Camera Drivers 1 Plug the USB drive into your PC then choose Open resp Explorer 2 Launch Install_DAVID CCD Camera_Driver may require administrator rights 3 Follow the instructions on screen Projector Settings The projector is shipped with optimal settings We recommend not to change anything in the projector s on screen menu You can restore the recommended settings in the projector s on screen menu any time 1 Select Reset 2 Be sure to switch Auto Keystone OFF and set the manual Keystone value to 0 For more information please refer to the projector s User Manual Setup Projector as Extended Desktop in Windows With your right mouse button click on a free space on your Windows desktop Choose Resolution or Properties depending on your Windows version Eigenschaften von Anzeige Designs Desktop Bildschimschoner Darstellung Einstellungen Ordnen Sie die Monitorsymbole so an dass sie der physikalischen Anordnung Ihrer Monitore entsprechen Screen Resolution File Edit View Tools Help Change the appearance of your displays Display 2 Acer Kia z Anzeige Uanain 200 x 600 recommended x 2 Plug und Play Monitor mit RADEON 9800 PRO Secondary Orientation Landscape z Bildschimaufi sung Earbquait t Niais J Hoch H chstezom 7 Make this my mi Show desktop o
6. ctive product may be returned to your supplier during the warranty period Ifthe warranty claim is valid you will be entitled to the repair of your device or a new device will be given to you This is free of charge Alternatively a warranty claim can be settled through reimbursement of the purchase price After the warranty period has expired you still have the option of sending the defective device to your supplier or to the DAVID Laserscanner after sales service for repair Repairs made after expiry of warranty will be subject to a charge Your statutory rights are not affected through this warranty Damage caused through improper handling use storage changes to the electronics lens or housing or through Acts of God or other external influences or any operation outside of the technical specifications are not covered by this warranty Before returning the device please contact your supplier to ensure your warranty claim is processed as efficiently as possible If it is not possible to process your warranty claim through your supplier you may as an exceptional case contact the DAVID Laserscanner after sales service directly Disposal Recycling Waste batteries or accumulators may not be disposed of as household waste Every consumer has a statutory obligation to properly dispose of these items at officially designated points of disposal Never discard electronic components of the DAVID Laserscanner in standard household waste In accorda
7. e You can find the number printed on the panels right next to the respective pattern The projector now shows a plane white or grey face You can adjust its brightness wit the Projector Brightness control so that the calibration markers are clearly visible in the camera image If there is enough environment light in the room you can set the control to 0 If necessary you can adjust the camera Exposure too 5 Click Calibrate in order to calibrate the camera In this step the software computes the position and orientation ofthe camera as well as the focal length and distortion parameters of its lens 6 From this moment on do not move or adjust anything at the scanner otherwise you will have to repeat the calibration 3 Menu Structured Light Scanning Calibration of the projector 1 When you open the Structured Light Scanning menu the projector will again show the setup pattern and both projector and camera will be set back to the settings you have made in step 1 2 Select a profile recommended default 3 Check the camera image again In those areas that show the circular wave pattern the red intensity curves must not be cut off at the blue borders Carefully adjust the lens aperture if necessary but be sure not to change the focus 4 Click Calibrate in order to calibrate the projector In this step the software measures the position and orientation of the projector its focal le
8. h each step In order for the automatic mode to find the correct alignment the scans have to overlap sufficiently i e contain a good portion of identical areas The button A starts the alignment mode In the 3D view first click on the scan you want to align Scan A Then click on the scan you want to align it to Scan B These images show an alignment of the blue scan to the green one Subsequently align more scans to those previously aligned Always select pairs which overlap as much as possible In the example shown above a good next step would be to align the yellow scan to the blue one and so on After all scans have been aligned you should run the Global Fine Registration mode 13 e Hint All scan movements can be undone separately with the Undo button 3 e Hint You can save your single scans at any time They will be saved in their current position and rotation in space so you won t have to align them again e Hint After some alignment steps it can be helpful to combine several scans temporarily Select two or more scans in the List of Scans press and hold the Ctrl key while you click Then click on them with the right mouse button and choose Combine This puts the selected scans into one group temporarily and allows you to tread them all as one In our example the Biissing bust we might combine scans 1 and 4 or all scans 1 4 and then align scan 5 to that group This way scan 5
9. n If the texture is too bright or too dark you can adjust the texture settings in the Texturing menu see below With your mouse you can rotate move and zoom the 3D view e The scans need to overlap sufficiently so that they can be combined aligned later on Generally 6 8 scans of different views around an object are required plus possibly a few of the top and bottom sides Grabbing a texture with each scan can help with the automatic or manual alignment Save each successful scan as an OBJ file Save As and or add it to the List of Scans After each click on Add to list you can immediately align the new scan to the previous ones Shapefusion menu see next chapter Alternatively you can first collect more scans in the Structured Light menu and align them all later Menu Texturing You can record a texture with each scan It is coloured if you are using a colour camera otherwise it is greyscale The texture usually requires different illumination settings When the Texturing menu is open you can adjust Projector Brightness camera Exposure or other camera properties as you like without influencing the scan settings A decent texture is like a good photo uniform illumination not too bright not too dark It may be helpful not to use the projector as a light source set Projector Brightness to 0 but instead use diffuse environment light in the room The button Grab Texture records a new textures and a
10. nce with the EU Directive 2002 96 EC on waste electrical and electronic equipment this must be disposed of in accordance with local regulations You can dispose of the product at your local public point for collection of electronic waste 2012 DAVID Vision Systems GmbH 15
11. nch DAVID by starting Start_DAVID3 on your DAVID USB key On the left side you can see the expandable main menus Each menu is dedicated to one ofthe following work steps which you will usually walk through from top to bottom For the individual work steps different camera and or projector settings may be optimal For example Camera Calibration may require a different Exposure Time or Texturing may require a darker projector setting The respective controls are available at all times and DAVID will remember and restore the settings separately for each work step depending on which menu is currently expanded Our software is developed and improved continuously Therefore please use the automatic update All updates within versions 3 x are free of charge This printed manual refers to version 3 4 of the software and may already be out of date Please also read our detailed and always up to date online manual which you can find on http www david laserscanner com Calibration of the Scanner One advantage of the SLS 1 s modular setup is that its size can be adjusted to very different object sizes Therefore calibration measurement of the current hardware setup in the DAVID software is required allowing the software to obtain undistorted 3D data at the correct scale We use a calibration corner as reference whose properties are known precisely The three steps hardware setup camera calibration and projector calibration must
12. ngth and distortion coefficients as well as optical transmission properties and delays of the whole system Your scanner is now calibrated This refers to the position and orientation of camera and projector relative to each other and the focus and brightness settings You may move rotate and tilt the scanner as a whole and you can close and restart the DAVID software without losing the calibration However if you rotate camera or projector with respect to each other or change the focus e g in order to scan much smaller or larger objects you will have to repeat the whole calibration procedure 10 3D Scanning Menu Structured Light Scanning BI Place scanner and object in front of each other like you did during calibration If the distance is too different the projected stripes and camera image will be out of focus In this case correct the distance not the focus rings Important For each scan observe that the red sine waves are not cut off overdriven this refers only to the image regions where the circular wave pattern is visible Should a correction be required carefully adjust the camera aperture but do not change the focus Each click on Start performs a new scan DAVID projects a set of different stripe patterns and records the images This takes 2 4 seconds depending on the settings 11 e Ifyou check the Auto grab texture option DAVID will record a texture with each sca
13. nlyon1 Advanced settings 800 x 600 Pixel lau zu zu Show desktop onlyon2 z Connect to a projector or press the A key and tap P Cl Windows Desktop auf diesem Monitor erweitern Make test and other items larger or smaller What display settings should I choose Identifzieren Problembehandluna Erweitert zz EEA Multiple display In this dialogue window you can separately change the settings of your two displays monitor and projector Your monitor should be set as main display Set the projector to be an extended desktop extend these displays extend desktop to this display This setting is required so that DAVID can project its scan patterns and show the user interface on your computer screen at the same time You can find more detailed instructions in our online user manual at http www david laserscanner com Manual in chapter 3D Structured Light Scanning When these settings are correct your monitor and projector will show different contents but with the same desktop wallpaper You can move the mouse pointer sideways from the monitor into the projected image The Windows Taskbar and most desktop icons will be shown only on the monitor All windows can be moved from monitor to projector and vice versa If the DAVID main window is shown on your projector grab its title bar with the mouse and move it over to your monitor Scanning with DAVID Lau
14. pplies it to the scan at hand All settings here are stored separately For the following scans you will not have to open the Texturing menu each time Instead you can use the Auto grab texture option in the Structured Light menu 12 Alignment and Fusion of Multiple Scans Menu Shape Fusion This menu offers to 1 align several scans to each other and 2 fuse them to one closed 360 model You can export the fused object in various file formats and use it e g for 3D printing In the following we describe the general case of aligning scans from arbitrary perspectives Hints about special cases and more detailed information can be found in the online manual on www david laserscanner com 1 Scan Alignment Single scans are usually collected in the List of Scans using the Add to List button during scanning You can also import scans from OBJ files by drag and drop or with the button below the list e Hint Each scan can be toggled visible invisible with the button e Hint If necessary you can clean your scan with the Selection Tool At this time you should only remove surface areas which are not useful for alignment i e which no pair of scans have in common Hint With the Arrange buttons E you can arrange all scans next to each other in order to get a good overview DAVID offers several alignment modes In general you should start with the Free mode which aligns one scan to one other wit
15. would be aligned to all scans which includes more overlapping areas and thus can lead to a more precise alignment Right click on the group s name in the list and choose Uncombine to separate the group again e Ifautomatic alignment cannot solve an alignment task correctly you can align scans manually by mouse keeping the Ctrl key pressed Please refer to the online manual for details 2 Scan Fusion Only visible scans will be fused so select all scans with the button e Click Fuse to start the Fusion This is a complex process which requires a computation time of several seconds or minutes All visible scans will be merged to one closed triangle mesh removing small artefacts If the scans have textures a fused texture will also be created Optionally all holes will be closed Finally you can use the Save button to export your fused 3D model as OBJ STL or PLY file 14 Terms of Warranty This device was manufactured using the latest production methods and has been carefully inspected All DAVID Laserscanner products are subjected to rigorous quality control Ifthis device nevertheless fails to perform faultlessly this is something we regret and we ask you to consult your supplier The following conditions apply to warranty claims This warranty is valid for a period of 24 months from the day of purchase Please keep the receipt carefully as proof of purchase when making a warranty claim The defe