Contents

1. Frequent vibration or impact exists Temp rature ambiante exc de 02 55 Vibration fr quente ou impact existe Daily average ambient temperature exceeds 35 C Rainfall or water droplet hits the product Temp rature ambiante quotidienne et moyenne exc de 35 C Pluie ou gouttelette frappe le produit e Relative humidity exceeds 5 to 95 or condensation is observed Exposed to direct sunlight Humidit relative exc de 596 9596 ou condensation est Expos lumiere du soleil directe observ e Metal pieces or conductive materials blow Altitude exceeds 2000 m Pi ce m tal ou mati re conducteur souffle Altitude exc de 2000 m Under strong electromagnetic field or noise Dust corrosive gas saline and oil smoke exist Sous champ lectromagn tique fort ou Poussi re gaz corrosif salin et huile fum e existe bruit Precautions concerning the installation Please read this instruction manual before installation he product shall be installed by a technician who has expertise in electric work such as safe installation and wiring Always handle the end face of metal parts with care The sharp part may cause injuries e During threading or wiring work take precaution so that any metal chip or a part of wire cut does not enter the product e Make sure to use the connection diagram for correct wire connection Incorrect wiring may cause the device malfunction
2. gt Q Q 5 Ethernet Max 4 levels 10BASE T Max 2 levels 100BASE TX 10BASE T 100BASE TX automatically detected Auto MDIX function straight crossover cable automatically detected Clock Additional difference of 0 5 seconds can be produced accuracy 25 C day 4 32 to 5 25 sec during outages Server section 25 C Backup data Backup is made using the battery Clock Measurement data for the last 1 hour Backup is made using nonvolatile memory CompactFlash memory card Setting values Measurement data except the one for the last 1 hour Battery ithium manganese dioxide primary battery Initial voltage 1800 mAh Life when in storage 5 years at room temperature actual service value 26 2 e 4 Specifications Energization Guaranteed value Guaranteed time after battery error time ratio occurs 13 700 hours 1 57 years 600 hours 25 days This indicates the assumed area of electric distribution to which the device is connected the area ranging from public distribution to factory machinery The measurement category ll applies to the device power supplied from fixed facility The surge voltage of this product is 2500 V up to the rated voltage of 300 V IEC 60664 1 The index indicates the level of conductive substance at the device s operating environment Contamination level 2 means only non conductive substance However occasional condensation m
3. 2 The installation of the designated computer is not completed Article 4 Limitation of liability 1 Mitsubishi Electric shall not guarantee that the Software is suitable or useful for the specific purpose intended by the user 2 Mitsubishi Electric shall assume no liability for any damage to the user or any third party s claim against the user arising from the execution of the license of use granted to the user under the Agreement Article 5 Alteration of the Software by user Any modification of the Software by the user shall not be allowed without written permission from Mitsubishi Electric Mitsubishi Electric shall assume no responsibility for the Software that has been modified by the user Article 6 Copyright The copyright to the Software shall belong to the Mitsubishi Electric The copyright to any reproductions described in Article 2 shall also belong to Mitsubishi Electric However the recording media on which the ooftware is recorded shall not belong to Mitsubishi Electric Article 7 Confidentiality The user shall keep confidential and must not disclose the Software its reproductions and the materials related to these The user must not leak to a third party any of Mitsubishi Electric s business secrets that the user may get to know under the Agreement Article 8 Duration of the Agreement The Agreement shall come into force when the user agrees to the Agreement and installs the Software and shall continu
4. 6th FI 105 Wu Kung 3rd Wu Ku Hsiang Taipei Taiwan R O C 95 0 1 202589 97 7 1 4411330 961 1 240430 92 0 42 7654342 63 0 2 634 8691 966 1 4770149 65 6473 2308 27 0 11 9282000 886 0 2 2306 8889 77 12 Bamrungmuang Road Klong Mahanak Pomprab Bangkok Thailand Avda Uruguay 1274 Montevideo Uruguay Calle 7 La Urbina Edificio Los Robles Locales C y D Planta Baja Caracas Venezuela 10th Floor Room 1006 1007 255 Tran Hung Dao St Co Giang Ward Dist 1 Ho Chi Minh City Vietnam 598 2 902 0808 58 212 241 9952 84 8 8386727 28 29 a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENK BLDG MARUNOUCHI 2 2 3 CHIY ODAKU TOKYO 100 8310 TELEX J24532 CABLE TOKYO LY3032728H21 1863652 1401
5. IP address 255 255 255 0 for the subnet mask and no gateway setting When you connect the product directly to a single PC you do not have to change these settings 5 Main Unit Installation Installation de l unit principale This product can be installed in two ways installation on an IEC rail 35 mm wide and direct installation on a board Le produit peut tre install au deux moyens installation sur un IEC rail 35 mm de large et installation directe sur une planche 5 1 Installation on IEC rail 35 mm wide Installation sur un IEC rail 35 mm de large 5 1 1 Mounting IEC rail mounting adaptor Montage d adaptateur pour monter sur IEC rail Mount the supplied IEC rail mounting adaptors small x 2 and large 1 on the back of the main unit Montez adaptateurs pour monter sur IEC rail petits x 2 et grand 1 sur le dos de l unit principale Back of main unit le dos de l unit principale Place the hook of the Push the upper part of the adaptor small into the adaptor small until you lower hole hear it click Placez le crochet de Appuyez sup rieur de l adaptateur petit dans le l adaptateur petit jusqu trou plus bas vous l entendez claquement Insert the adaptor large from below into the Push the lower part of the adaptor large grooves on the base unit until you hear it click Ins rez l adaptateur grand de bas dans la Appu
6. each operation Operation history monitoring point 64 KB x 4 x the number of operation monitoring points Transfer Zoom Daily Monthly Transfers data on the hour data for 1 Automatically transfers data to a function hour on the hour data for the day on the specified FTP server specified hour of the day data for the month Display function Zoom Displays 1 hour data collected at Analog value Line graph Measurement value 1 minute intervals Displays 2 sets of data at a time each for a separate measuring point or for a separate day Analog value Line graph Measurement value Displays 2 sets of 1 hour data Power factor collected at 1 minute intervals at a time each for a separate day Daily Electric energy Pulses graph Usage amount on the hour oron Displays 1 day of data collected Virtual measuring point the half hour on the hour or on the half hour Line graph Specific consumption and Displays 2 sets of data at a time accumulated energy amount on each for a separate measuring the hour or on the half hour point or for a separate day Analog value Line graph Measurement value Displays 2 days of data Power factor collected on the hour or on the half hour at a time Equipment Bar graph Usage amount on the hour or on the half hour Line graph Specific consumption and accumulated energy amount on the hour or on the half hour Specific consumption Bar graph Production amount and energy Displays 2 days o
7. exceeds 35 C e Rainfall or water droplet hits the product e Relative humidity exceeds 596 to 9596 or condensation is Exposed to direct sunlight observed Metal pieces or conductive materials blow Dust corrosive gas saline and oil smoke exist Under strong electromagnetic field or noise Precautions for disposal The product shall be properly disposed of in compliance with the Wastes Disposal and Public Cleansing Act The product has a built in lithium battery The lithium battery shall be disposed of in compliance with your local regulations e n EU member states there is a separate collection system for waste batteries Dispose of batteries properly at the local community waste collection recycling center The symbol shown below is printed on the batteries and packaging of batteries and devices with built in batteries used for Mitsubishi programmable controllers Note This symbol is for EU member states only The symbol is specified in the new EU Battery Directive 2006 66 EC Article 20 Information for end users and Annex The symbol indicates that batteries need to be disposed of separately from other wastes There may be some electricity left in the lithium battery removed Keep it away from other metal parts because its contact with the metal parts may cause heat rupture or fire Network building For installation and setting of web browsers and JavaVM Java Virtual Machine and
8. fire or electric shock Never do hot line jobs Otherwise it may lead to electric shock fire or device problems Use appropriate size of electric wires If inappropriate size of electric wire is used it may cause fire due to generated heat Use an appropriate size of solderless terminal which fits the wire If inappropriate solderless terminal is used wire breakage or contact failure may occur which may cause the device malfunction failure burnout or fire For UL c UL standard please use the copper conductors wire which temperature rating is 60 C 75 Pour UL c UL standard utilisez le conduit en cuivre dont la temp rature class e 60 C 75 C terminal block RAV2 3 5 section terminal block dedicated cable Contact output section 0 3 to 0 75 mm R1 25 3 terminal block Solderless terminals with a crimp sleeve cannot be used e Make sure all the fittings are securely tightened Failure in tightening may cause the device malfunction fire or electric shock Assurez vous que tout le serrage est fermement serr Manque de serrage peut causer mauvais fonctionnement du dispositif feu ou commotion lectrique e Fixing fittings must be tightened to the specified torque Excessive tightening may cause damage to terminals or Screws Fixation du serrage doit tre serr e a couple de serrage sp cifi Serrage excessif peut endommager du terminal ou vis Insufficient tightening may cause the device malfunction f
9. m tal de fixation pour toucher troitement l unit principale et serrez le vis sup rieur avec un tournevis Couple de serrage 1 00 1 35 Nem IEC rail Follow 1 to 3 LEE 1 Fix the DIN rail 2 Move the fixing metal bracket to the main body 3 Loosen the fixing metal bracket Left side 3 Suivez de 1 a 3 1 Fixer le DIN rail 2 Mettre la ferrure en m tal de fixation a l unit principale 3 Desserre la ferrure en m tal de fixation 5 Check that the right and left fixing metal brackets are secured to the IEC rail V rifiez que la ferrures en m tal de fixation en droite et gauche sont fermement attach es rail 6 Check that the right and left fixing metal P metal aon fads metal T 1 5t brackets are secured to the IEC rail Te CN V rifiez que la ferrures en m tal de fixation en droite et gauche sont fermement attach es l IEC rail 15 5 2 Direct installation on board Installation directe une planche 1 Undo the fixing screws on the top of the unit for the power supply section and the unit for the contact output section D boutonnez les vis pour fixation l unit qui sont sup rieurs de l unit pour la section d alimentation lectrique et de l unit pour la section de contact sortie 2 Remove the unit for the power supply section and the unit for the contact output section Retirez l unit pour la section d alimentation lectrique e
10. mandatory to attach the noise filter to power source lines but the noise could be reduced if it is attached Recommended Model gt Model Name FN343 3 01 Rated Current 3A Supplier SCHAFFNER 8 2 Ethernet communication section Section de communication Ethernet 8 2 1 For initial setting IP address setting Pour les r glages initiaux adresse IP fixation Supplied CD setting software Logiciel de r glages LAN cable straight or crossover Droit ou m tiss PC PC 21 8 2 2 For operation Pour op ration Client PC PC client le LAN cable straight C ble de LAN Droit LAN RER FIHDAEIUD Hub Hub 22 8 3 Ethernet communication section CH2 to PLC Section de communication Ethernet CH2 8 3 1 For operation Pour op ration LAN cable Cable de LAN Droit Intranet HUB R seau d intranet LAN HUB LAN C ble de LAN Droit LAN Cable de LAN Droit Ethernet Serial converter Convertisseur Ethernet S rie Connect to link unit Connectez a de lien PLC Connect to LAN adaptor or Ethernet unit Connectez au port Ethernet ou l unit Ethernet de PLC ETT Ld Please see the details in PLC s instruction manual Voyez le mode d emploi de PLC en d tail series PLC is only supported for serial communication by using Ethernet Serial converter S rie
11. position Off Memory card is ready to be removed MODE Operation Lights green During standard operation mode Lights orange During startup in hardware self diagnostic mode Lights red At the time of occurrence of a battery error Error display Blinks red During initial startup after purchase During electric outage due to batter exhaustion n Sep 1 en status Lights green Startup i is completed LAN Off Connected at 10Mbps Lights green Connected to LAN Off Not connected to LAN Blinks LAN communication in progress Server section SD RD communication Operation status of Lights green CC Link communication section is normally running RUN Off CC Link communication section is under abnormal conditions CC Link communication Lights green During normal operation CC Link master This LED lights green all the time because the product stays in CC Link master mode during operation SD CC Link Blinks green Transmitting through CC Link communication LN Blinks green Receiving through CC Link communication CC Link m E ee communication L RUN CC Link link Blinks green Linking through CC Link communication section status Off No link through CC Link communication CC Link Off During normal operation This light is off all the time because the product stays in CC Link master mode during operation Blinks red at regular intervals The switch on the CC Link communication section is
12. right and left screw holes in the lower side of this product and tighten all the mounting screws Placez deux bornes de montage dans les trous de vis en droite et gauche en bas du produit et serrer toue les bornes de montage 7 Mount the unit for the power supply section and the oe unit for the contact output section EE Montez l unit pour section d alimentation Crochet pour fixation t l unit lectrique et l unit pour la section de contact de sortie Unit fixing protrusion Saillie de fixation l unit Unit fixing lever Levier de fixation l unit Unit fixing hole Vs L unit a arrang le tou 8 Tighten the unit fixing screws on the top of the unit for the power supply section and the unit for the contact output section Tightening torque 0 36 to 0 48 N m Serrez les vis pour fixation l unit au sommet de l unit pour la section d alimentation lectrique et de l unit pour la section de contact de sortie Couple de serrage 0 36 0 48 Nem 17 6 Battery Installation and Replacement 6 1 Installing battery This product is shipped with the battery connector removed Before use make sure to connect the battery connector Make bundles of excess lengths of lead wire on the top of the battery 1 Open the battery cover on the bottom of the product inside the main unit as shown below 2 Check th
13. transfer to the FTP server has failed Check whether communication with the FTP server is normally running or settings in the FTP server are correct The battery backup RAM is initialized when you use the product for the first time or when you keep the product nonenergized for more than 3 minutes with the battery exhausted or disconnected If you cannot solve your problem according to the check items above contact your supplier or us 13 Warranty This document and product have undergone strict quality control and inspection before delivery but in the unlikely event that the document or product is defective in manufacture our company shall provide replacement Contact the distributor from which you purchased them However this warranty does not apply to the product or document that has been damaged by acts of God or misapplication Our company shall not be liable for any damages arising out of your or third parties system troubles legal problems misapplication failures during use or any other defects The product is warranted for a period of less than one 1 year from the date of your purchase from the date of delivery to your specified location or within eighteen 18 months from the date of shipment from our factory from the month and year of manufacture whichever is less warranty period shall not be renewed after repair 33 Software License Agreement This Software License Agreement here
14. C MELSEC PLC po eris model G series L series QnA series A series FX series Number of Total number of measuring points 255 points Up to 32 of 255 points are operation monitoring measuring points measuring Number of virtual measuring points 128 points points CC Link terminals Number of specific consumption measuring point Number of equipment measuring points 42 points Collects data at 1 5 minutes intervals on the hour or on the half hour on the Daily Virtual measuring point Four arithmetic operations with parentheses Arithmetic operations are done can be performed on up to 16 arithmetic based on data collected on the elements hour or on the half hour Specific consumption Divides energy amount by production amount measuring point A measuring point or virtual measuring point is specified for each amount Monthly Virtual measuring point Four arithmetic operations with parentheses Arithmetic operations are done can be performed on up to 16 arithmetic based on data collected on the elements specified hour of the day 64 points Saving function Zoom Daily Monthly Yearly For 62 days 1 minute or 14 days 5 minutes Saved in CompactFlash memory 186 days 60 months 5 years card Specific consumption measuring For 186 days only on a daily basis point Virtual measuring point For 186 days on a daily basis 60 months on a monthly basis Records changes from ON to OFF in operation monitoring input for
15. Check wiring conducted in step 8 This completes the installation procedure Read Precautions concerning the installation carefully to perform the operation safely elf the product gives off abnormal noise smell smoke or heat turn the power off immediately Setting The following explains the preparation for operating the product after it is installed 1 Use the supplied CD to install the setting software on your PC 2 Use the configuration software to set an IP address for the product See 7 IP Address Setting of this instruction manual When you use the factory default setting 192 168 10 1 for IP address you do not have to perform this step 3 Use the configuration software to set a date and clock for the product See Instruction Manual Configuration 4 Configure client computers to your network environment For details on settings contact your network administrator For details on setting procedures see the instruction manual of your computer or contact its manufacturer b Configure the web browsers in the client computers See Instruction Manual Operation 6 Set necessary information such as connected devices and measuring points See Instruction Manual Configuration 7 Check the product operation See Instruction Manual Operation eWrong network settings may cause other devices on the network to malfunction e The factory settings for this product are as follows 192 168 10 1 for the
16. FX est seulement soutenue pour la communication en s rie au moyen de convertisseur Ethernet S rie About the Ethernet Serial Converter we have check operation with LINE EYE 51 65 23 8 4 CC Link communication section Section de CC Link communication Energy saving data collecting server CC Link slave CC Link slave master station station station Serveur collecte de donn es Station affranchie Station affranchie conomie d nergie station maitre de CC Link de CC Link 1100 1 2W R sistance de terminal 1100 1 2W Terminal resistor 1100 1 2W R sistance de terminal 1100 1 2W Blue Bleu White Blanc Yellow Jaune CC Link dedicated cable Cable r serv CC Link CC Link dedicated cable Cable r serv CC Link Point The maximum transmission distance depends on the CC Link communication speed setting Distance de transmission maximale compte sur la fixation de la vitesse de communication Perform wiring according to the following table so that it will not exceed the maximum transmission distance R alisez le c blage selon la table suivante afin qu il n exc de pas la distance de transmission maximale Communication speed Vitesse de la communication Cable length between stations 20 cm or longer 20 cm or longer 20 cm or longer 20 cm or longer 20 cm or longer Vitesse de la 20 cm ou plus 20
17. MITSUBISHI ELECTRIC gt Energy Saving Data Collecting Server EcoWebServer III Model MES3 255C EN Instruction Manual Hardware B Preface Thank you for purchasing Mitsubishi s Energy Saving Data Collecting Server EcoWebServer Ill This instruction manual explains how to install and use the product Please read it carefully and use the product properly Make sure to read 1 Safety Precautions on page 3 for proper use before installing the product Keep this instruction manual in an accessible place for future reference whenever needed Make sure it is delivered to the end user Package and instruction manual To reduce environmental burden we use e Cardboard for the package Recycled paper for the instruction manual Packaged contents Make sure all the following items are in the package White x 2 Black 11001 2W Fe 13001 2W Energy saving data collecting server CC Link iod resistor main unit Small x 2 Compact Flash memory card software DIN rail mounting adaptor DIN rail mounting set Instruction manual included DIN rail mounting screw M5 x 10 Setting software Battery built in the bottom of the main unit s server section Instruction manual this document Table of Contents SALLY Precautions Me nets as nn sense nissan dote ni ee nent 3 2 Man mi cie D i i ERO E
18. OD PE 7 3 Name and Function of sata sine Pc RS AN NN 8 4 Procedures for Installation and Setting ccccccccecccssesseeceeeeeeeeeeeeceeeeeeeaeeeeceeeeeseaeaeseceeeesseeuaeeeeeessseeaeeeeeeeeessaagsees 11 5 Unit IS AN ATOS EORR 12 5 1 Installation on IEC rail 35 mm wide sn nant oU Rb cuin ie arr li het 12 oO Mounting IEC ral tolg adaptor esis iss dresse te sos les aede 12 5 1 2 Mounting IEC rail fixing square washer ccecccccceeeeeeeeceeeeeeeecuaeeeeeeeseeeeeeeesaeeeeeesseeeeeeesaaeeeessaaeeeeeesaaseees 13 S nstaling mah Unt OM IEG Taies ee tea et ee sitne 13 o P FIXO MAN UN eaea M 15 52 DISCUSSION ON DOME SE tf ss aoi quse RU 16 6 Battery Installation and Replace meN HL Oto cese eb e kae meti ca LB cae etu 18 6 1 Metalno AUG AY tita eem 18 6 2 n 18 7 RU BIS RP PR HEc 19 7 1 use aia itas au aci M DEMEURE cielo tic ICI 19 7 2 Checking IF address TT 20 8 COMME CHONADIA Ol AIM RR ne 21 8 1 POWENSUDDIY SECON EET OD COLD LEN 21 8 2 Ethernet communication section ss ioni Roos Dv Delo d n qe hate at ue fe ane ler Ee tege 21 8 2 4 For initial setting IP address setting sise 21 Bec o Co
19. at battery is properly installed 3 Insert the connector on the battery into the 6 2 Connector Battery lead wire case side connector pin in the right direction Replacing battery When the battery reaches its end of life the ERR LED on the server section lights red Replace the battery with a new one See 12 Options on page 25 1 Open the front cover on the server section and hold the RESET SELECT switch to the SEL position Connector main unit side When the CF CARD LED goes out turn this product off Open the battery cover on the bottom of the server section Connector Remove the battery from the holder battery side Insert a new battery into the holder in the right direction and connect the lead connector to the connector Battery Close the battery cover Turn this product on sure to perform battery replacement with electricity off ePerform battery replacement within 3 minutes If 3 minutes passes with the battery removed the data for the last 1 hour and the clock setting may be initialized The data and setting values older than those for the last 1 hour are not initialized If the IP address and clock settings are initialized reconfigure those settings after backing up the data 18 7 IP Address Setting 7 1 Setting IP address 1 Connect this product directly to a single PC that has the configuration software installed in it
20. ation numbers from the station number 1 to the last station number are counted as reserved station units Broadcast polling method 24 V DC 2A resistance load Rated switching 240 V AC 2A COS qQ 71 1 point 8 A 1 common voltage current 24 V DC 2A resistance load 240 V AC 2A COSqQ 71 1 point 8 A 1 common Life Mechanical 20 000 000 times or more electrical 100 000 times or more at rated switching voltage current 27 To make EcoWebServerlll EMC compatible the noise reduction parts must be installed in accordance with the following The noise reduction must be the parts of the table below or equivalent Distance from the terminal EMI FILTER NF2060A RQ 2 SOSHIN ELECTRIC CO LTD 2 CLAMP FILTER 2 2235 1030 TDK 01234567 l 89ABCDEF L CLAMP FILTER 40 to F COM output section E D class grounding EMI EMI 100 to 240 V AC FILTER FILTER CC Link CLAMP FILTER CC Link terminal CC Link terminal LL LAN cable straight or crossover CLAMP FILTER 28 9 2 Software specifications Specifications Up to 64 ME96NSR ME110SSR C ME110NSR C EMU2 RD3 C EMU2 RD5 C EMU2 R D7 C EMU2 RD2 C 4W EMU2 RD4 C 4W EMU3 DP1 C MDU WS V MDU W Terminal model S AE SW BIF CC AJ65BT 68TD AJ65BT 64RD3 AJ65BT 64AD AJ65SBTB1 8D AJ65SBTB1 16D AJ65SBTB1 32D AJ65SBTB1 16DT AJ65SBTB1 32DT Q J61BT11N LCPU LJ61BT11 No Up to 32 PL
21. ay lead to temporary conduction IEC 60664 1 For UL c UL standard please use the copper conductors wire which temperature rating is 60 C 75 C If the unit is reset when power failure compensation is not available by expiration of power failure compensation period set time would be changed to the initial status 00 00 on 1st of January 2002 If the time is changed with this status measured data may be disappeared Necessary data should be measured before changing the time setting About the data collecting method please refer to Data Collecting part in chapter 4 7 1 for maintenance of the user s manual Settings Specifications CC Link communication section Contact output section 156 kbps 625 kbps 2 5 Mbps 5 Mbps 10 Mbps Max transmission distance Speed between stations 156 kbps 625 kbps 2 5 Mbps 20 cm or longer 5 Mbps 10 Mbps Max number of connected 164 units under the following conditions 1 Total number of stations a bx2 cx3 dx4 lt 64 a number of units occupying 1 station b number of units occupying 2 stations c number of units occupying 3 stations d number of units occupying 4 stations 2 Number of connected units 16 x A D 54 x 88 x c lt 2304 A Number of remote station units Max 64 units B Number of remote device station units Max 42 units C Number of local station and intelligent device station Max 26 units units D Number of reserved station units Unregistered st
22. cartez les lignes de contr le des lignes lectriques autant que possible Taille de c ble regardez la page 3 Si COM sera connect aux points plusieurs terminaux doit tre dispos par client When a counter or timer that uses a DC DC converter is connected as a load its inrush current should be below the maximum load current of the contact output section Si l un comptoir ou chronom tre ce qu il utilise un DC DC transformateur sera connect comme une charge le courant d afflux doit tre inf rieur au courant de charge maximum de la section de contact de sortie If the inrush current is large perform any one of the following to reduce the impact of the inrush current Si le courant d afflux est grand r alisez l un des suivants pour diminuer l impact du courant d afflux Contact Resisor output section Section de R sistance Charge sortie contact Inductance Contact output section Inducteur Section de Charge sortie contact 25 9 Specifications 9 1 Hardware specifications Specifications Input power supply dm Entr e d alimentation lectrique 100 to 240 V AC 41076 15 Input frequency Fr quence d entr e 90 60 Hz 45 S INS VA at 110 V AC 25 VA at 220 V AC ie A 8 ms less 20 ms ou moins 100 V ou plus Ro LN ms or less 100 V AC or higher interrup
23. cking IP address 1 Open the front cover on the server section and set the MODE STOP RUN switch to the STOP position Hold the RESET SELECT switch to the SEL position 3 After the CF CARD LED turns off turn the RESET SELECT switch to the RES position 4 After all the LEDs except the POWER LED on the power supply section turn off return the RESET SELECT switch to the central position b Wait until the product starts up and the IP address is displayed on p the 7 segment LED at the front CL IP address display Display example of 192 168 10 1 set in the product 1 7 1 110 i 1 iR He Ic HB ei Ht a d Hexadecimal CO Hexadecimal A8 Hexadecimal 0A Hexadecimal 01 Decimal 192 Decimal 168 Decimal 10 Decimal 1 6 After you finish checking the IP address turn the MODE STOP RUN switch to the RUN position 20 8 Connection Diagram 8 1 Power supply section Section de l alimentation lectrique Note See more notice in page 3 Live wire fortifications is NOT allowed Noise filter Wire size refers to page 3 Filtre de bruit FG LG is exclusive for D class grounding Please connect L N over a noise filter Note Voyez les remarques sur la page 3 Fil sous tension N est PAS permis filter Taille de c ble regardez la page 3 FG LG est r serv s exclusive aux bases AC100 240V de classe D D class grounding It is not
24. cm ou plus 20 cm ou plus 20 cm ou plus 20 cm ou plus communication Max transmission distance Distance de transmission maximale Max transmission distance Distance de transmission maximale Energy saving data collecting server master station Terminal Serveur collecte de donn es Terminal resistor conomie d nergie station maitre resistor R sistance de R sistance de terminal terminal Remote station Remote device Remote device Local station Local station Station I O isol e station station Station locale Station locale Station de Station de Remote I O station Station I O isol e dispositif isol e dispositif isol e 24 8 5 Contact output section Section de sortie contact 01234567 89ABCDEF Load Charge 6 L 8 Point 100 200 V AC or 24 V DC 100 200 V AC ou 24 V DC Note See more notice in page 3 To prevent induction noise keep control lines and communication cables as far away from power lines as possible Wire size refers to page 3 Terminals are arranged by the guests when COM is connected to several points Note See more notice in page 3 Pour emp cher le bruit d induction
25. e in force for the duration until the Agreement becomes invalid due to any of the following 1 The user can terminate the license of use within one month after written notice is given to Mitsubishi Electric 2 Mitsubishi Electric can terminate the license of use if the user violates the Agreement Article 9 Domestic use only The user must not take the Software out of Japan or send it to any area outside Japan without prior written permission from Mitsubishi Electric Article 10 Termination When the license of use under the Agreement is terminated the original Software and all its reproductions printed materials etc shall be returned to or a document proving that these are destroyed shall be sent to Mitsubishi Electric within one month from the date of such termination All costs for such return or destruction shall be incurred by the user 34 Energy Saving Data Collecting Server Trademarks Windows Windows xP Windows Vista Windows 7 and Internet Explorer are trademarks registered trademarks and products of Microsoft Corporation in the United States and or other countries Java all Java based trademarks and logos are registered trademarks and products of Oracle Java Inc in the United States and or other countries e CF are trademarks of SanDisk Corporation e Ethernet is a registered trademark of Fuji Xerox Co Ltd EcoServer i
26. ecified in 9 Specifications of this manual If it is used outside the ratings it may cause not only malfunction or failure but also fire or burnout Settings including an IP address assignment are required to connect the product to the network Ethernet Before use perform an IP address assignment and other necessary network settings using the supplied configuration software Refer to IP Setting of Setting manual The product is configured as follows when shipped from the factory When you connect the to a single TE Hoi us change settings The product has a built in clock Before use set the current date using the supplied configuration software eBefore operating the product check that active bare wire etc does not exist around the product If any bare wire is found stop the operation immediately and take appropriate action such as isolation protection e Please contact our sales staff when you consider applying the product to special purpose including use in devices and systems for nuclear plant aerospace engineering medical care or automobile See the end of this document for details eCurrent might exceeded the specified value when the power is cycled immediately after the power is breaking off in 5 seconds Please turn on the power more than 5 seconds after breaking off Caution eDo not disassemble or modify the product It may cause failure electric shock fire Precaut
27. f data amount on the hour or on the collected on the hour or on the half hour half hour at a time Displays data for the specified day collected on the hour or on the half hour Weekly Specific consumption Line graph Specific consumption and Displays 7 days of data accumulated energy amount collected on the hour or on the the hour or on the half hour half hour Bar graph Usage amount for 1 day Displays 2 sets of 1 month data Monthly Electric energy Pulses Virtual measuring point Line graph Accumulated usage amount and collected at 1 day intervals accumulated daily planned amount each for a separate month or for a separate measuring point Yearly Electric energy Pulses Bar graph Usage amount and planned Displays 1 year of data collected amount for 1 month at 1 month intervals Line graph Accumulated usage amount and Displays 5 sets of data at a time accumulated planned amount each for a separate year or for a separate measuring point Current value group Displays accumulated current values hourly differences daily differences or monthly differences of current values for measuring points registered as a group up to 32 groups up to 255 points per group Measurement values for 0 points can be displayed in a screen Current value separately chosen Displays accumulated current values hourly differences daily differences or monthly differences of current values for measuring points registered in a di
28. ff If you turn the product off or reset it without performing this procedure you may lose the data saved in the CompactFlash memory card CompactFlash memory card slot server section the dedicated CompactFlash memory card included in the package when the power is off Always operate the product with the CompactFlash memory card in the slot If the CompactFlash memory card is not in the slot the product will not operate Terminal block power supply section Terminal Function symbol Power filtering ground m Power supply 100 to 240 V AC Terminal block CC Link communication section Function symbol CC Link communication line A DB CC Link communication line B CC Link communication line ground CC Link communication line shield Both ends of the shield line for CC Link dedicated cable should be connected to SLD of the unit Perform D type Type 3 grounding work dedicated for the FG terminal of each unit SLD and FG are connected together inside each unit CC Link station number setup switch CC Link communication section eSet Hold the switch to O Ken Note Itis set to 0 when shipped from the factory Do not change the setting If itis set to any position other than 0 CC Link communication cannot be conducted CC Link communication speed setup switch CC Link communication section 0156 Kbps 3 15 Note 1 Set to the same c
29. inafter referred to as the Agreement is applicable to the relevant software hereinafter referred to as the Software manufactured and sold by the Mitsubishi Electric Corporation hereinafter referred to as Mitsubishi Electric Software means all programs on the recording media and all related documents Article 1 License of use Mitsubishi Electric shall hereunder agree to grant the user the license to use the Software and the user shall accept all provisions stated below and agree not to assign such license of use to anyone other than contractors and not to possess an exclusive license of use Article 2 Reproduction of the Software The user must not reproduce all or part of the Software except for the following 1 The reproduction of the Software is only allowed when this is for the security of the Software and the use of such reproduction is limited to the designated computer This shall only apply to the software for which preparations for enabling the reproduction of the Software has been made Article 3 Use for computers other than the designated computer The Software shall not be used for computers other than the designated computer However if any of the following events occurs the Software can temporarily be used for a computer other than the designated computer for the period until such event ceases to exist 1 The designated computer cannot be used due to the work for maintenance adjustment failure etc Or
30. inquiries about their technical issues contact your network administrator or appropriate department For installation and setting of servers such as SMTP mail transfer servers and FTP file servers and inquiries about their technical issues contact your network administrator appropriate department or the manufacturers for those servers e We don t offer technical support for the above QR code QR code is for production management Please do not use 2 Features The product has an HTTP server function that can send data over the Internet Intranet via Ethernet that is collected from measuring instruments using CC Link communication The transmitted information can be viewed in a graph or list format on PCs connected to the Intranet the software programs necessary to view collected data are built in the product You do not have to install additional software on your PC to view the data E Also installing a mail server SMTP server or file transfer server FTP server allows you to send email notifications when an upper lower limit alarm operates and to save measurement data in a CSV format by automatic transfer View the graph Internet Explorer EcoWebServerlll setting software Transfer collected CC Link terminals FTP Server PLC data collecting SMTP Server SNTP Server Ethernet EcoWebServerlll EcoWebServerlll Time adjustment Report by Email Output b
31. into the IEC rail Accrochez l adaptateur l IEC rail Push the lower part of the main unit until you hear it click Appuyez inf rieur de l unit principale jusqu vous l entendez claquement 14 5 1 4 Fixing main unit Fixation de l unit principale To prevent vibration when you transport the product installed on a board make sure to fix the product using IEC rail fixing metal brackets Hook Fixing metal bracket Ferrure en m tal de fixation 1 Loosen the screw on the top of the fixing metal Crochet bracket EY Desserrez le vis au sommet de ferrure en m tal de fixation Hook A Crochet Place the hook into the upper side of the IEC rail Placez le crochet en haut de l IEC rail 2 Place the lower hook of the fixing metal bracket into the lower side of the IEC rail Placez le crochet inf rieur de ferrure en m tal de fixation en bas de l IEC rail 3 Place the upper hook of the fixing metal bracket into the upper side of the IEC rail Placez le crochet sup rieur de ferrure en m tal de fixation en sup rieur de l IEC rail lower side of the IEC rail Placez le crochet en bas de l IEC rail Place hook into 4 Slide the fixing metal bracket to come into intimate contact with the main unit and tighten e the screw on the top with a screwdriver Tightening torque 1 00 to 1 35 N m Glissez la ferrure en
32. ions for maintenance and inspection Use a soft dry cloth to clean off dirt of the product surface Do not let a chemical cloth remain on the surface for an extended period of time nor wipe the surface with thinner 4 Check for the following items to use the product properly for a long time Check for the items 1 to 3 once or twice every six months Check for the item 4 once a year 1 No damage on the product 2 No abnormality with LED indicators 3 No abnormal noise smell or heat 4 No looseness with installation wire connection to terminal blocks and connector connection Check these items under the electric outage condition eChecking looseness with installation wire connection to terminal blocks and connector connection must be done under the electric outage condition Precautions for storage o store the product turn off the power and remove wires and put it in a plastic bag To keep the power off for a long time remove the battery connector The battery s accumulated backup time for electric blackout is 13 700 hours 1 57 years Failure to use a battery over backup time may cause a data clear of the product For long time storage avoid the following places Failure to follow this instruction may cause failure and reduced life of the product Ambient temperature exceeds 25 C to 75 C e Frequent vibration or impact exists e Daily average ambient temperature
33. ire or electric shock Serrage insuffisant peut causer mauvais fonctionnement du dispositif feu ou commotion lectrique Partie Couple de serrage Terminal screw for power supply section M3 5 screw terminal block Borne de terminal pour terminal bloc Vis M3 5 oO dans la section d alimentation lectrique Terminal screw for CC Link M3 screw communication section terminal block Borne de terminal pour terminal bloc Vis M3 0 42 to 0 58 N m dans la section de CC Link communication Mounting screw for CC Link ipsi iu section terminal block M3 5 screw Borne de montage pour terminal bloc Vis M3 5 0 66 to 0 89 N m dans la section de CC Link communication Terminal screw for contact output M3 screw section terminal block Borne de terminal pour terminal bloc Vis M3 5 dans la section de contact sortie Mounting screw for contact output M3 5 screw section terminal block Borne de montage pour terminal bloc Vis M3 5 dans la section de contact sortie Unit fixing screw M3 screw x 12 Vis pour fixation l unit Vis M3 0 36 to 0 48 Nm 0 66 to 0 89 N m eMake sure that all the terminal covers are mounted Failure to mount them may cause electric shock Assurez vous que tout les couvercle sont attach s Manque d attachement peut causer mauvais fonctionnement du dispositif feu ou commotion lectrique To prevent induction noise keep control lines and communication cables as far away fr
34. le iioii REN EE REED a 22 8 3 Ethernet communication section CH2 to PLO cccccccccssseceecceeeeeeecceeeceeeseeueeeeeseeaeceeeseaeceesssegeeeeseaeeeessaas 23 odo i es qo 23 8 4 GO Link comtimunieatiod RS oto uu 24 8 5 Contact OUMOUTSSCH ON RO E ns 25 9 Tn Hr M HU H 26 9 1 mises eite SS CI ALOT NE T PO 26 9 2 Feo eue etudes caet a 29 9 3 ue tense ie MA soute da ie D m used 30 10 ETS Fal ee ae cc Na re 31 10 1 External dios OldS ESS cas oet haan ee solerent 31 10 gt Seting conditions mM 32 11 tU e a cer 32 12 FOUDISS OO RAR EEUU Us 33 13 33 1 Safety Precautions Precautions concerning the operating environment and usage conditions Do not use the product in the places as follows Failure to follow this instruction may cause malfunctions and reduced life of the product Ambient temperature exceeds 0 to 55
35. n the 7 segment LED on the server section is displayed on the 7 segment LED on the server section 4 is displayed on the 7 segment LED on the server section 01 is blinking on the 7 segment LED on the server section els power supply 100 to 240 V AC 50 60 Hz properly connected between L and N on the terminal block of the power supply section eis there any short circuit or break in the power line Is JavaVM Java Virtual Machine installed You need to install JavaVM in client PCs to display graphs Visit the following URL for installation http www java com Is there any error in communication with CC Link terminal devices Check whether CC Link terminal devices CC Link station numbers and CC Link baud rate are properly set and communication cables and termination resistance are properly connected battery is at the end of its life Replace the battery See 6 2 Replacing battery Please check if the battery is properly connected The data in the CompactFlash memory card is being restored during startup The product starts up normally after a few minutes Access to the internal memory has failed Reset the product Access to the CompactFlash memory card has failed Reset the product Automatic time synchronization with the SNTP server has failed Check whether communication with the SNTP server is normally running or settings in the SNTP server are correct File
36. na 200336 10 F Manulite Tower 169 Electric Road Morth Point Hong Kong Carrera 53 No 290 73 Medellin Colombia 9 Rostoum St Garden City P O Box 165 11516 Maglis El Shaab Cairo Egypt Gothaer Strasse 8 D 40880 Ratingen Germany Plot No 32 Sector 6 IMT Maneser P O Box 5045 Kawasan Industri Pergudangan 61 2 0684 7777 1 847 478 2100 55 11 3146 2200 56 32 2 320 600 86 21 2322 3030 852 2887 88 10 20 2 27961337 57 4 235 30 38 49 0 2102 486 0 91 124 4695300 62 0 21 6610651 9 62 2 3660 95 72 856 21 215043 961 1 240445 603 5569 3748 1480 6 Gayang Dong Gangseo Gu Seoul Korea 43 47 Lane Xang Road P O BOX 2789 VT Vientiane Laos Cebaco Center Block Autostrade Dora Box 11 2597 Beirut Lebanon 5 Jalan Pemberita U1 49 Temasya Industrial Park Glenmarie 40150 Shah Alam Selangor Malaysia NO137 139 Botataung Pagoda Road Botataung Town Ship 11161 Yangon Myanmar KHA 2 65 Volt House Dillibazar Post Box 2108 Kathmandu Cebaco Center Block Autostrade Dora Box 11 1314 Beirut Lebanon 1416 Brandreth Road Lahore 54000 Pakistan 24th Fl Galleria Corporate Center Edsa Cr Ortigas Ave Quezon City Metro Manila Philippines A Shuwayer St Side way of Salahuddin AFAyoubi St P O Box 15955 Riyadh 11454 Saudi Arabia 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Private Bag 2016 Isando 1600 South Africa
37. oft Windows XP Professional 32bit SP3 Microsoft Windows Vista Business 32bit SP2 Microsoft Windows 7 Professional 32bit 64bit SP1 Web browser Internet Explorer 7 Internet Explorer 8 32bit Internet Explorer 9 32bit JavaVM Oracle JAVA 6 JRE 6 32bit Oracle JAVA 7 JRE 7 32bit 30 0 c 0 c E e T ES LLI o 10 1 External dimonsions Front Side 946 p snl mi Bottom Unit mm 31 10 2 Setting conditions The space conditions is necessary for heat dissipation and battery replace Position of ceiling of the board trunking or other parts S NS Over 5mm D Over 30mm Over 80mm door SS SS When trunking is less than 50mm In other cases is over Product name Model name Replacement battery 32 12 Troubleshooting If the product gives off abnormal noise smell smoke or heat turn the power off immediately Check the following items for troubleshooting Check items Nothing is displayed Graphs cannot be displayed The ERR LED on the CC Link communication section is lighting or blinking The ERR LED on the server section is lighting The STA LED on the server section is blinking for a long time E1 is displayed on the 7 segment LED on the server section E2 is displayed o
38. om power lines as possible We recommend that you keep a distance of 100 mm or longer between them Do not place them in a board containing high voltage equipment Mount surge absorbers on equipment that is likely to produce noise eConnect both ends of the shield line for CC Link communication cable to the SLD terminal of the units SLD and FG are connected together inside each unit Make sure to insulate the shield line using vinyl tape or the like eFor the actual usage perform D type grounding dedicated for the FG terminal ePerform insulation withstand voltage tests and insulation resistance tests without connecting the FG terminal to the external case ground Precautions concerning the preparation before use Make sure that your installation site meets the requirements for the operation environment and usage conditions Before use perform the settings for the product Wrong settings may cause the product to malfunction Check the power ratings of the product After installing the product and performing wiring work peel off the dustproof seal Failure to peel it off may cause the product to malfunction due to heat generation The product has a built in lithium battery It is not connected to the product when shipped from the factory Connect it before using the product Refer to 6 Battery Installation and Replacement of this manual Precautions for use Use the product within the ratings sp
39. ommunication speed the CC Link terminals connected to the product they operate at different communication speeds communication cannot be conducted Note 2 The switch is set to 0 communication speed 156 kbps when shipped from the factory Terminal block contact output section symbol 0 to 9 Ato F Contact relay output 0 to 9 Ato 100 to 240 V AC or 24 V DC Contact relay output common common for output 0 to 9 A to 10 4 Procedures for Installation and Setting B Installation The following explains the operations from package opening to installation 1 Open the package 2 Check the packaged contents See Packaged contents on page 1 of this instruction manual 3 Insert the supplied CompactFlash memory card into the memory card slot 4 Connect the battery mounting connector See 6 1 Installing battery of this instruction manual 5 Check that the CC Link station number setup switch is set to 0 See CC Link station number setup switch in 3 Name and Function of Each Part of this instruction manual 6 Set a communication speed using the CC Link communication speed setup switch See CC Link communication speed setup switch in 3 Name and Function of Each Part of this instruction manual 7 Install this product See 5 Main Unit Installation of this instruction manual 8 Conduct wiring See 9 Connection Diagram of this instruction manual 9
40. on with the cover opened Bottom CompactFlash memory card EJECT button Push the button to eject the CompactFlash memory card MODE STOP RUN switch Set it in the RUN position for normal operation RESET SELECT switch Use to reset the product CompactFlash memory card Programs for collecting and 10BASE T 100BASE TX displaying data are stored in it It is also used to save collected data 1 Battery storage section Battery is stored in it Open the cover to connect a connector 1The CompactFlash memory card should be in the product all the time Removing it while the product is operating or it is been accessed may cause the product to malfunction Before removing it from the memory card slot make sure to hold the RESET SELECT switch to the SEL position and to turn the power off after the CF CARD LED goes out 2Connect a power supply of 100 240 V AC 41096 15 50 60 Hz Do not connect any power supply other than the above otherwise it may cause malfunction LED display E FOWET Supply POWER Lights green Power is section displa Lights green MODE STOP RUN switch is set to RUN position in Operation normal operation display Off MODE STOP RUN switch is set to STOP position in the IP address display mode RUN Lights green Memory card is accessible CF CARD Memory card Blinks green Memory card is being removed status RESET SELECT switch is held to SELECT
41. operated with power on Error status of Blinks red at irregular intervals Termination resistance is not installed L ERR CC Link The unit or CC Link dedicated cable is being communication influenced by noise Lights red The settings don t correspond to the connected equipment 0 t0 9 Ato F Off Contact output is open section status Lights red Contact output is closed LNA interface CH1 CH2 100BASE TX 10BASE T Ethernet 1 100 specifications MCN speed UTP Unshielded twisted pair cable media segment 100 m to hub ength MODE STOP RUN switch 5 MST standby master Turning the product on or resetting it with the switch in the STOP position displays the IP address currently specified for the product See 7 2 Checking IP address Usually use the product with the switch in the RUN position RESET SELECT switch Use to reset the product After you set the switch to the RES position hear it click and see all the LEDs except POWER on the power supply section go off return the switch to the central position Holding the switch to the SEL position during operation stops the reading writing of the CompactFlash Make sure to perform this procedure before turning the product off or resetting it Before turning the product off or resetting it make sure to hold the RESET SELECT switch to the SEL position and to see the CF CARD LED turn o
42. s a registered trademark of Mitsubishi Electric Corporation Other company names and product names in the manual are trademarks or registered trademarks of their respective owners Australia USA Mitsubishi Electric Australia Pty Ltd Mitsubishi Electric Automation Inc MELCO TEC Rep Com e Assessoria Tecnica Lida China Mitsubishi Electric Automation CHINA Ltd China Mitsubishi Electric Automation HongKong Ltd Proelectrico Representaciones 5 Eo M itsubishi Electric Europe B V Indi Mitlite Electric Company Pvt Ltd a F Korea Mitsubishi Electric Automation Korea Co Lid Societe Lao Co Lid Comptoir d Electricite Generale Liban Peace Myanmar Electric Co Ltd Watt amp Volt House Comptoir d Electricite Generale International S A L Prince Electric Co Middle East Arab Countries amp Cyprus Philippines Saudi Arabia Center of Electrical Goods Edison Electric Integrated Inc South Africa Thailand United Trading amp Import Co Ltd Vignol SA CBLelectric low voltage Setsuyo Enterprise Co Ltd Venezuela Jakarta Indonesia 348 Victoria Road Rydalmere N S W 2116 Australia 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Av Paulista 1439 72 Cerqueira Cesar CEP 01311 200 Sao Paulo SP CEP 0131 1 200 Brazil Agua Santa 4211 P O Box 30 D Vina del Mar Chile No 1386 Hongqiao Road Mitsubishi Electric Automation Center Shanghai Chi
43. splay list file up to 10 files Measurement values for up to 10 points can be displayed in a screen Email Error monitoring Monitors server startup reset read write errors on CompactFlash memory notification card measuring errors file transfer errors automatic clock adjustment errors battery errors monitoring against the planned monthly energy values Target Specific Performs an hourly monitoring of up to 64 measuring points for the actual consumption values against the target specific consumptions monitoring Operation monitoring Monitors up to 32 operation monitoring points for changes Sends up 8 messages to the specified destinations once a day week or month on the specified hour Error monitoring Monitors server startup reset read write errors on CompactFlash memory card measuring errors file transfer errors automatic clock adjustment errors battery errors Monitors up to 32 measuring points analog value for their upper lower limit monitoring monitoring against the planned monthly energy values Target specific Performs an hourly monitoring of up to 64 measuring points for the actual consumption values against the target specific consumptions monitoring monitoring points function annual basis Clock setting Reading and setting of the current date IP address setting Sets an IP address subnet mask gateway address and up to 3 DNS addresses 9 3 Operation environment Specifications OS Micros
44. t de l unit pour la section de contact 3 Mount two board mounting screws M4 x 12 on the board to fix the upper side of this product Montez deux bornes de montage M4 x 12 sur la planche pour fixer le c t sup rieur du produit 4 Hook the notch in the right side of this product on the right screw Crochez le cran du c t droite du produit sur le vis droite 16 Push Appuyez Raise a 4 Relevez 2 w Z5 Unit fixing hook Crochet pour fixation l unit Board Planche Notch Cran Board Planche 5 Hook hook slot in the left side of this product the left screw pct EO Crochez le cran du c t gauche du produit sur le vis Fente crochet w P gauche Mounting screw hole Trou pour monter le vis Both right and left sides Les deux c t en droite et gauche Board Planche L 6 Place mounting screws into the
45. tion time oma apu min Withstand voltage L N terminals output terminals L N terminals CC Link communication terminals LN terminals extemal case Insulation resistance L N terminals output terminals L N terminals CC Link communication terminals Memmi By noise simulator with a noise voltage of 1500 Vp p a noise width of 1 us and a noise Noise immunity frequency of 25 to 60 Hz Noise voltage IEC61000 4 4 2 kV 0 to 55 C Storage ambient temperature 25 to 75 C Operating ambient humidit 5 to 95 RH Input voltage distortion m Distorsion Within 5 Common Storage ambient humidity 5 to 95 RH Vibration resistance Constant Half Conforming to Intermittent 9 10 9 Hz 85mm j0times in JIS B 3502 each X Y Z 61131 2 vibration 9 to 150 Hz 9 8 m s2 Continuous 509 Hz ag pe vibration 9 to 150 Hz 49m s2 Impact resistance Conforming to JIS B 3502 IEC 61131 2 147 m s2 3 times in each XYZ direction No corrosive gas Operating altitude 2000 m or below Inside a board Il or below 2 or below 0 9 kg Built in unchangeable by user ERR Application Off when no power is input the product is reset or fuse blows terminal Rated switching 24 V DC 0 5A voltage current section Min switching load 5 V DC 1 mA Life Mechanical 20 000 000 times or more electrical 100 000 times or more at rated switching voltage current
46. using a LAN straight cable or crossover cable 2 Take a note of the IP address set in the PC IP Address ex Subnet mask x X Default gateway 2 amp 3 Change IP address set in the PC according to the IP address factory setting 192 168 10 1 set in the product IP address for the product IP address for the PC 192 168 10 1 192 168 10 xx xx is a value from 1 to 255 The upper 3 digits should be consistent with those for the product 4 Launch the configuration software to set a new project b Open the Configuring the IP address screen to enter an IP address for this product 6 Enter the maintenance password factory setting ecopass in the Password field and click the Change button IP address setting Password maintenance Direct write memory card CH1 IP address setting before changing IP address setting after changing IP address subnet mask Default gateway DNS setting before changing Number of DNS c DNS Server 1 DNS Server 2 DNS Server 3 CH2 If you not want to input and out ange the IP address settings of CH2 IP address setting before changing IP address setting after changing IP address 92 168 IP address 192 166 Subnet mask 255 25h 255 0 Subnet mask 255 255 2 Default gateway Default gateway 7 After you change the IP address for the product return the PC s IP address to its original address 19 7 2 Che
47. y Email when over upper and lower limit or operation status changed CC Link Ethernet b 4 ang ine T n odi Jo oiis Hi is A PLC 19 Bg g a EcoMonitorPro gem 4 Write collected data EMU3 Electronic to PLC device med MDU measuring breaker instrument Remote I O Analog unit unit Temperature input QE series CC Link 3 Name and Function of Each Front CC Link Power supply Server communication ee section section section 7 segment LED display Displays an error code when an error is detected on the product PORR AR Also displays the IP address set opu A sus LED display in the product when you start it m m ER up in the IP address displa MM ode di Croze os CC Link station 50 60Hz 40VA 1 swe ox number setup switch USB interface Not used LAN interface CH1 Connect to client PC CC Link transmission speed setup switch Contact output terminal block Contacts are closed when LAN interface CH2 Connect to PLC monitoring conditions are satisfied Connect external devices such as buzzers or lamps Power supply terminal block Connect a power supply 2 AC _ CBASE T 100BASE 1X in S CC Link terminal block LED display Connect a CC Link State display communication cable Front Server secti
48. yez inf rieur de l adaptateur grand rainure du unit de base jusqu vous l entendez claquement 12 5 1 2 Mounting IEC rail fixing square washer Montage de rondelle carr e pour fixer IEC rail Use square washers and mounting screws M5 x 10 to fix the IEC rail to the position where the main unit will be installed Utilisez rondelles carr s et bornes de montage M5 x 10 pour fixer l IEC rail dans la position o l unit principale sera install e Square washer IEC rail Mounting screw Rondelle carr e IEC rail Borne de montage IEC rail IEC rail View A D 08 Square washer Installation side MEN Rondelle carr e board etc Mounting screw bat Vue A M5x10 di Borne de montage M5 x 10 Keep 80 to 90 mm between the square washers Maintenez de 80 90 mm entre des rondelle carr es IEC rail fixing square IEC rail washer IEC rail Rondelle carr e pour fixer IEC rail Somme 80 90mm Point Make sure to place the square washers parallel to the IEC rail Assurez vous placer des rondelle carr es en parall le de l IEC rail Square washer IEC rail Square washer IEC rail Rondelle carr e IEC rail Rondelle carr e IEC rail EE 5 1 3 Installing main unit on IEC rail Installation de l unit principale sur IEC rail 13 Hook adaptor

Download Pdf Manuals

image

Related Search

PDF:1.7MB pdf 1 mb pdf 1 mb converter pdf 1 mb compress pdf 1 mb size pdf 1 mb resize pdf 1 mb compressor pdf 1 mb converter ilovepdf pdf 1 mb yapma pdf 1 mb to kb pdf 17 barcode generator

Related Contents

MYOTRAC INFINITI™ User Guide  HP ZBook 14 Mobile Workstation Hardware Reference Manual  リニアブッシュ取扱説明書  Quick reference GuiDe  1997 Oldsmobile Eighty Eight  RCD-91105B04-manual cover  Semiconductor Characterization System Technical Data  Olive Cart Basic 取扱説明書  MANUAL TÉCNICO  Philips 5ZH-CN SA3MXX08 User's Manual  