1. 3 Remove 2 or 3 knockouts from the top of the panel 4 Install utility input conduit and wire from a dedicated circuit breaker such as provided for a fire alarm or security system Voltage should be 120VAC 60Hz for 120V models and 277VAC 60 Hz for 277V models 240VAC 50Hz for 240V models 5 Install wires from switch legs if switch function is being used See diagram on panel door 5 Install emergency output conduit to emergency loads ensure that load voltage rating matches inverter voltage 6 When you receive the panel it will already have indicating LED s and test switch visible on the bottom of the panel The panel has a protective cardboard cover during shipment which should be removed after the panel has been securely mounted AC Input Output Wiring Instructions The CEPS must be installed by a qualified electrician in accordance with local state and NEC codes AC amp DC Voltages are hazerdous and care should be taken to follow all instructions Prior to wiring AC connections disconnect AC Input feed at relevant branch circuit breaker s Always wear appropriate clothing when handling batteries and equipment and use insulated tools 1 Remove fuse from bottom side of panel 2 Ensure that inverter rocker switch is in middle position OFF and that batteries are not connected 3 Ensure that knockouts on top of panel have been removed and conduits have been installed 4 Bring AC Input conductors and AC Output Co
2. in a workman like manner so that low voltage and line voltage connections do not share the same area If CEPS output does not match specifications or is stuck in emergency gt mode please consult the following troubleshooting guide Test 1 Remove fuse mounted on bottom of panel and check continuity Replace with 6A 250V fuse if neces sary Re insert all fuses Test 2 Observe indicator lights on blue inverter mounted in left of panel If LED s are flashing or are RED in color turn rocker switch to OFF middle position then back to REMOTE towards top of panel All LED s should become green or yellow if not consult LVS Inc Check that GFCI is not tripped Test 3 Allow 72 hours for batteries to charge and run battery voltage test described on page 3 If voltage is still irregular consult LVS Inc regarding battery wiring and replacement Test 4 Check all wire nuts for good electrical connections and ensure that no bare conductors are exposed Also ensure that all plug in connectors are firmly inserted and locked If replacing loose connections first discon nect all power and remove fuse from bottom of panel 4
3. Model CEPS 120 Model CEPS 240 Model CEPS 350 Installation Instructions amp User Manual UL924 LISTED EMERGENCY LIGHTING EQUIPMENT 73PK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS When using electrical equipment basic safety precautions should always be followed including the following Do not install outdoors Do not install near gas or electric heaters Mount CEPS ___ securely and in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel Do not use this equipment for other than its intended use All installation and servicing of this equpiment must be performed by qualified personnel The use of accessory equipment not specified or recommended by LVS Inc may cause unsafe conditions and may void the warranty Use caution when servicing batteries Battery acid can cause burns to skin and eyes If acid is spilled on skin or in the eyes flush with fresh water and seek medical attention immediately Make sure all connections are in accordance with NEC and local regulations Check AC Voltage rating on equipment label Do not connect to any other voltage 10 An unswitched AC power source is required 120 VAC or 240VAC or 277VAC depending on model 11 Do not use this product for other than intended use 12 To reduce risk of electric shock disconnect dedicated input breaker and all fuses before servicing 13 Do not attempt to service sealed component
4. ipped freight prepaid within the warranty period to the address below To the extent permitted by applicable law all warranties extending beyond repair or replacement as described above are disclaimed including the implied warranties of merchantability and fitness for a particular purpose Where applicable law prohibits disclaimers or the implied warranties of merchantability and fitness those warranties are limited to 12 months from date of shipment LVS provides a 90 day money back guarantee if equipment does not perform in accordance with LVS published specifications The liability of LVS and its agents under all warranties is limited to repair and replacement as described herein and under no circumstances shall there be liability for any other kind of loss damage or labor either consequential or for injury to person or property or otherwise Batteries are supplied on a pro rata basis for six years provided that the product 2 has been properly installed in the correct surroundings Panel Location 1 Panel should be installed in a ventilated indoor location and not subjected to temperatures above 100 F 37 8 C nor below 40 F 4 5 C and at an altitude of less than 10 000 feet for optimum performance 2 When the panel is installed on the wall the wall must have sufficient strength to support a weight of 100 pounds and a minimum of 4 screws 10 should be securely fastened in wood or concrete with plastic inserts to secure the panel
5. nductors through the appropriate conduits Per NEC emergency output circuit should be installed in a dedicated conduit 5 Connect AC Output conductors to wires 8 hot and 10 neutral 6 Connect AC Input conductors to wires 1 hot and 2 neutral 7 Connect grounds for AC Input amp AC Output to stripped ends of grounding wires provided Battery Installation 1 Remove batteries from shipping boxes and check for enclosure and terminal damage 2 Check to ensure correct number of batteries CEPS 120 1 battery CEPS 240 2 batteries CEPS 350 3 batteries 3 Measure DC voltage between and terminals of batteries all readings should be between 11 5V and 14V If battery voltage is too high or too low contact LVS at 1 800 982 4587 3 Leave protective sleeves on battery wires till ready to make final connections Always make connections one at atime Always connect black to black Always connect red to red 4 Consult diagram on panel cover for proper battery wiring 5 Ensure that all connections have been made in a workman like manner and that panel door can close Start Up 1 Set inverter rockerswitch in REMOTE position rocker should be up towards top of panel 2 Insert 250V 6A fuse into bottom side of panel 3 Ensure that cabinet is securely fastened to wall and that no wires are loose or disconnected 4 Ensure proper grounding of all system components and enclosures 5 Ensure all final connections have been made
6. nterruption Distortion Less than 3 Utility amp Inverter Power Indicator LED s Test Switch to simulate utility power loss Safety amp Protection V Safe momentary overload Up to 700 W for safe operation when using high inrush loads TEMPORARY STORAGE INSTRUCTIONS For temporary storage of CEPS system and batteries prior to installation select a clean cool dry location with normal ventilation suitible for human habitation and level floors DO NOT store system or batteries in a sealed room or container Ensure that floor is cabable of bearing load Donot store batteries for more than 60 days without charging Doing so will cause irreversible damage to battery cells and void battery warranty Ensure batteries are stored at temperatures within the following range 40 F to 100 F e 3 Year Warranty 6 Year Pro Rata Battery Warranty LVS Inc warrants to the original purchaser user for the published warranty period from the date of shipment that should LVS instruments or equipment prove defective by reason of improper workmanship or material LVS will repair or replace the same equipment without charge This warranty does not cover defects or malfunctions arising from improper installation operation or repair or neglect accident or abuse LVS will honor its warranty provided the equipment has not been physically damaged or improperly installed or connected To obtain warranty repair the defective product should be sh
7. s with the exception of standard battery replacements SAVE THESE INSTRUCTIONS a LVS Inc 2555 Nicholson Street San Leandro CA 94577 4216 I Phone 510 352 9600 1 800 982 4587 Fax 510 352 6707 www lvscontrols com Unit Specifications Input 120VAC or 240VAC or 277VAC 50 or 60 Hz 8 W Power Consumption when batteries charged Output 120VAC or 240VAC or 277VAC 50 or 60 Hz Pure Sine Wave CEPS 120 120W 1A at 120V 0 43A at 277V CEPS 240 240W 2A at 120V 0 86A at 277V CEPS 350 350W 2 9A at 120V 330W 1 2A at 277V 90 minutes run time at full load Output fused GFCI protected 120V models only Automatic Output Voltage Tracking maintains output Thermostat Controlled Silent Cooling Fan Power Factor Unity using incandescent loads 0 9 leading to 0 9 lagging depending on load 1 5 seconds transfer time to protect against momentary ON OFF voltage surges caused by power line hitting wet pavement or other power lines during a storm Operating Temperature 40 F to 100 F Frequency Regulation 3 Automatic low voltage battery disconnect voltage at full load at 120V 3 for a full 90 minutes emergency operation Efficiency Over 90 at full load Sealed Lead Calcium batteries provide long life and are maintenance free EMI in compliance with FCC Class A Regulation Operates fluorescents CFL LED halogen incandes cent loads Loads can be switched or dimmed during normal operation full brightness during i