NESS D16
Contents
1. button for 4 seconds 1 Press C User Code 0r Cx Cx together If Double Key Panic has been enabled by your installer If Panic Shortcut has been enabled by your installer or by RADIO KEY press and hold the PANIC For personal protection the keypad contains a PANIC feature which can be used to instantly trigger the alarm The PANIC function may have been programmed to be either AUDIBLE activates siren or buzzers or SILENT If your system is monitored by a Central Station sends a PANIC report by dialler If PANIC reports have been enabled by your installer PANIC cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate PANIC button To activate the panic alarm simply press that button DURESS 1 Disarm by pressing 5 6 8 or 9 User Code E A DURESS alarm can be triggered to alert the Central Station that you are being forced to Disarm the panel against your will To Disarm and send a DURESS alarm prefix your User Code with one of the digits 5 6 8 or 9 when Disarming DURESS alarms are only used if your system is monitored by a Central Station DURESS IS NORMALLY NOT ENABLED TO ENABLE THE DURESS FUNCTION CONSULT YOUR INSTALLER 12 NESS D16 CONTROL PANEL USER MANUAL EXCLUDING ZONES EXCLUDING ZONES eor JJ 1 Press User Code JJJ If Exclude Sho
2. NESS D16 16 Zone Control Panel and Dialler I de M Coa hy ec SCIL 2 OO INEZ D 6 OWNER S MANUAL REVISION 2 JULY 2001 Australia s largest designer and manufacturer of high quality security products Quality Endorsed a Company 1809001 LIC No QEC2074 Ness Security Products Pty Ltd NSW Head Office only WWW NESS COM AU HEAD OFFICE Ness Security Products Pty Ltd ACN 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au SYDNEY 02 8825 9222 MELBOURNE 03 9878 1022 BRISBANE 07 3343 7744 ADELAIDE Aquavia Controls 08 8277 7255 PERTH 08 0328 2511 NEW ZEALAND NFS NZ 64 9 573 0401 REVISION 2 JULY 2001 D16 USER MANUAL Document Part Number 890 247 For product 100 687 D16 Control Panel 2001 Ness Security Products Pty Ltd ACN 069 984 372 D16installer4 pmo200701 Specifications may change without notice CONTENTS Features teca tenete ee ete ER ied 4 Introduction redderent ici renes 5 Keypad ient dne ti ERR RE nri ERR ek ien 6 Visual Indicators 3 iet ii epis 7 OPERATION 453 p rd E Epio dos 8 RIMMING oce ca eee eee eet dd tdi geo es 9 Disarming eter pite 10 Resetting Alarms siirinsesi nnti 10 Monitor Mod n isinin teisese 11 Panic pesi ii eiri iaria aea ets 12 DUr SS iaie aai
3. Another detection device used is called a Reed Switch Reed Switches are attached to windows and doors to detect if a window or door has been opened A Reed Switch consists of a magnet which is normally attached to the moving part of a window or door and the Reed switch which mounts to the door or window frame The panel is Armed when it is set to detect an intruder At other times it is Disarmed Normally a zone is considered Sealed Activation of a detection device will cause the zone to be Unsealed and may cause an alarm Detectors such as fire detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setting A zone with this assignment is called a 24 hour zone Some detection devices may be required to generate an alarm or warning only when the panel is Disarmed A zone with this assignment is called a Day zone Before leaving the premises you must Arm the panel to enable it to detect intruders and generate an alarm After arming the panel will ignore detectors during the Exit Delay Time to enable you to depart without triggering an alarm Arming the system may be done through the keypad or with the use of optional Radio Keys for Arming by remote control from outside the premises When you enter the premises the panel will ignore selected zones for the Entry Delay Time and will not alarm unless you don t Disarm the panel during this allowed time Disarming the system may
4. Press P then E JJJ To exit Program Mode The PROGRAM light will turn off EXAMPLE 3 To program ENTRY DELAY 1 EXAMPLE 4 To program EXIT DELAY DDOD JJJ VLG e JJJ VLG Ld Enter the new time Enter the new time 1 99 seconds 1 99 seconds r PROGRAMMING FOLLOW ME TELEPHONE NUMBER 1 Press P MASTER CODE E JJJ Enters Program Mode The PROGRAM light will turn on 2 Press P 0 0 E ddd The existing Telephone No will be displayed by the keypad lights 3 Press CJ C C C CJ CJ i CJ E Jj The new Telephone No will be displayed Enter the new Telephone Number 4 Press P then E JJJ To exit Program Mode The PROGRAM light will turn off EXAMPLE 5 To program the Follow Me Telephone Number WOWW 444 QOOOOOSC0 Enter the new Telephone Number Up to 15 digits long EXAMPLE 6 To delete the Follow Me Telephone Number POW add E NESS D16 CONTROL PANEL USER MANUAL 17 WIRELESS PRODUCTS RADIO ACCESSORIES Ask your installer about the range Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door The Ness Radio Key provides the benefits of separate ON OFF and PANIC buttons in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel NESS
5. and then Arm again Continual warnings could mean that a detector is faulty and may have to be manually excluded If the auto exclude option is disabled the siren will sound for the duration of reset time if a zone is Unsealed at the end of exit time NESS D16 CONTROL PANEL USER MANUAL EN DISARMING YOUR ALARM SYSTEM DISARMING 1 Enter the protected premises via a delay zone 2 Press User Code E JJJ or by RADIO KEY press the OFF button 3 The ARMED light will turn off When you enter the protected premises through a delay zone the keypad responds with regular beeps as a reminder to Disarm You then have your programmed entry delay time to Disarm the panel by entering one of your user codes If the panel is not Disarmed by the end of the entry delay time an alarm will occur By using the optional radio keys you may Disarm your system from within your premises or from outside your entrance door 1 RESETTING AN ALARM 1 Press User Code E JJJ or by RADIO KEY press the OFF button There is also the option to Chirp the outside siren three times and to flash the strobe light for two seconds as an indication that you have Disarmed your system If you make a mistake in entering your code then you must press enter and start again Five incorrect entries will cause an alarm If Entry Beeps are programmed on Your panel can be reset and the alarm silenc
6. interface for controlling the many powerful features of the D16 system Information is displayed on a large LCD icon display which is backlit for easy night viewing DISPLAY TEST To display all the keypad icons press and hold the E button for at least 2 seconds All the icons will be on whilst the button is held down Display Test can be activated at any time either in operating mode or any program mode NESS LCD KEYPAD 100 667 BACKLIT LCD ICON DISPLAY Not Ready light ARM2 ALARM TAMPER RADIO FO B MONITOR BATTERY MAINS EXCLUDE PROGRAM LINE 12345687 9 10 11 12 13 14 15 vai amp m READY ARMED amp 8 16 KEYPAD BEEPER Not Ready o PANIC BUTTONS EACH KEY PRESS d 1 beep ARM BUTTON VALID ENTRY ddd 3 beeps MONITOR BUTTON ERROR BEEP JIL 1 long beep EXCLUDE BUTTON MAINS POWER IS OFF MEMORY BUTTON or BATTERY IS LOW JTLOTL 10 beeps PROGRAM BUTTON The Not Ready light is on when the panel is not ready to Arm i e a zone is unsealed there may still be movement in the premises or a door or window left open ENTER BUTTON EN NESS D16 CONTROL PANEL USER MANUAL VISUAL INDICATORS KEYPAD LIGHTS OPERATION NESS LCD K EYPAD 100 667 LIGHT O OFF on LS FLASHING ZONES 1 16 Zone Sealed Zone Unsealed Zone Alarm ARM
7. on board 100 203 sounder A single battery powers the smoke detector and the transmitter NESS D16 CONTROL PANEL USER MANUAL AUDIBLE MONITORING CENTRAL STATION MONITORING The D16 control panel has an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and Disarm the system Central Station Monitoring is highly recommended and is the most effective method of monitoring your D16 alarm system For further information about 24 hour monitoring contact your installer or Ness Security Products AUDIBLE MONITORING The D16 can also be programmed to send audible messages to any telephone or mobile phone When programmed for audible monitoring the D16 calls a pre programmed number or numbers and sounds a series of beeps over the phone These beeps can identify the zone or zones which caused the alarm and well as several other alarm types CENTRAL STATION MONITORING EM MONITORED PREMISES TELEPHONE LINE AUDIBLE MONITORING rr MONITORING STATION FIXED TELEPHONE MONITORED PREMISES TELEPHONE LINE MOBILE TELEPHONE FOLLOW ME TELEPHONE NUMBER Alarms are normally reported
8. that the D16 is connected to SEQUENCE OF OPERATION 1 Phone the D16 telephone number and listen for the required number of rings ring ring ring ring and then hang up 2 Wait 10 seconds and then call the number again within 50 seconds 3 The D16 will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The D16 is now ready to receive telephone commands 4 Press the 9 button on the telephone This tells the D16 that telephone commands will follow The D16 will respond with either 3 beeps if all OK One long beep means try again 5 Now enter a valid User Code that is normally used for Arming or Disarming the D16 followed by the st button The D16 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the required command See Summary Of Telephone Commands 7 Press x st to finish This tells the D16 to hang up Also hang up your telephone AUDIBLE FEEDBACK JJJ 3 BEEPS The User Code is valid Successful Arming or Disarming An Auxiliary output has been turned ON J J L 1 LONG BEEP D16 is already Armed Invalid code Try again J 1 SHORT BEEP An Auxiliary output has been turned OFF NOTES If the D16 does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up If an
9. ED Disarmed System Armed AREA 1 ARM2 Disarmed System Armed AREA 2 MONITOR Disarmed Monitor Mode MAINS Normal Mains Power Fail BATTERY Normal Backup Battery is Low MEMORY Normal Memory Mode selected Alarms in memory EXCLUDE Normal Exclude Mode selected Zones Excluded TAMPER Normal Tamper unsealed Tamper Alarm PROGRAM Normal Client Program Mode LINE Normal Dialler is transmitting Bsp d or Failure To READY gt Zone unsealed or System is ready to Arm gt Phone ine faul Rano Born Radi Gy 3 Cher Hi dt D bt ado device ib ou low battery battery NOT READY Ready to Arm Not ready to Arm light NESS D16 CONTROL PANEL USER MANUAL Ea OPERATION This section describes the operation of a typical control panel installation Keep in mind that your installation may vary depending on the selected options and equipment The operating instructions which follow will endeavour to cover the most common options Consult your installation company if you require further information All control panel operations are controlled by the D16 keypad except if an optional key switch or radio control equipment is installed OPERATING RULES Generally the panel will be Disarmed Armed or Monitor modes provide different levels of security for your premises when you are home or away Three other temporary modes Program Memory and Exclude allow you to perform various operations The panel will automatically exit from these temporary
10. RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the Ness D8 D16 amp D24 control panels Part No 100 001 Also operates Monitor mode and Panic when used with the Ness D16 D24 panels The Ness radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires NESS RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Part No 100 662 NESS RADIO KEY 3 BUTTON Fully waterproof ultra slim 3 button Radio Key for remote control of the D16 control panel Part No 100 664 With separate buttons for ON Arm OFF Disarm and PANIC functions c NESS RADIO KEY PENDANT 0 Fully waterproof pendant style transmitter can be used as a Part No 100 665 portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes NESS RADIO PIR J Ness Radio PIR Passive Infrared motion detector for wireless motion detection n Can be used in combination with Part No 100 663 Ness hardwired detectors in areas where it is not possible to install wires NESS RADIO SMOKE Uff DETECTOR 7 Radio Smoke Detector using lonisation smoke detection Part No technology With
11. a meet tei lea i a han 12 Excluding Zories itii ect is 13 Alarm Mernoly iniiis isea nsa ied detinet 14 PROGRAMMING essen 15 Programming Options Table 15 User Code programming eeeeess 16 Entry Exit Timer programming 17 Telephone Number programming 17 Wireless Accessories eneee 18 Monitoring described ssssssssss 19 Remote Operation by Telephone 20 Troubleshooting iisi isipin gerse 22 Installation Record Ainiin 23 NESS D16 FEATURES 8 or 16 Fully programmable zones Any combination of 8 or 16 hardwire or radio zones Full radio supervision Contact ID Dialler Format Ultra Modern and Impact resistant Housing Ness Audible Dialler Format Follow Me Audible Dialler Option Separate 24 Hour Tamper input Single or Double Trigger Zones Remote LCD Keypads Max 3 Fully programmable via the system Keypad Eliminates the need for expensive programmers or Proms Inbuilt Vibration Sensor Analyser All programming data is permanently stored in a non volatile EEprom memory True Dynamic Battery Test every time the Panel is Armed Disarmed and every hour Area Partitionable 2 Areas Any Zone can be programmed to any area as well as common areas Comes complete with an AC plug pack and supports a 12V 7Ah battery to maintain system security under all power
12. alarm occurs which requires the D16 to dial out while attempting remote control the D16 will treat the alarm as a priority give a constant tone as a warning and then hang up When all remote control commands are finished press x st to force the D16 to hang up EJ NESS D16 CONTROL PANEL USER MANUAL REMOTE OPERATION EXAMPLE ARMING THE D16 BY TELEPHONE 1 Dial D16 telephone number Listen for 1 double ring then hang up 2 Wait 10 seconds then dial the D16 telephone number again 3 The D16 answers immediately and gives a 2 second beep followed by low tone 4 PRESS 0 To prepare the D16 NAM 3 beeps 5 PRESS User Code s to authorise the next command 3 beeps 6 PRESS 4 to Arm the panel QJ 3 beeps 7 PRESS x st to finish and hang up SUMMARY OF TELEPHONE COMMANDS Prepare to receive commands Arm Areas Disarm Areas Turn Aux 1 Output ON or OFF Turn Aux 2 Output ON or OFF Finished hang up 5 3 9 2 9 se s 89 89 NESS D16 CONTROL PANEL USER MANUAL EI TROUBLESHOOTING SYMPTOM Zone light on or long beeps when Arming POSSIBLE CAUSE One or more Zone Detection Devices e g PIR Reed Switch may be Unsealed REMEDY Close door or window find the cause of movement 10 beeps from keypad MAINS light flashing BATTERY light flashing The mains power may be off The backup battery may be low A Radio Device battery may be low Ma
13. be done by keypad or with the use of optional Radio Keys Monitor mode allows selected zones to be Armed while leaving others Disarmed if you wish to protect a number of zones while you are at home If you wish to split your alarm system into two areas with access limited to each area by code numbers then Area operation is used Radio Keys can also Arm and Disarm Areas The control panel housing and the covers over external sirens are protected by tamper switches to detect someone attempting to disable the security system Activation of these switches will cause an instant tamper alarm If a detector becomes faulty you can Exclude the associated zone so that it is totally ignored and cannot generate an alarm Including the zone will enable it to generate an alarm again The control panel is fitted with a rechargeable stand by battery to ensure your security system continues to operate if the mains power is interrupted This control panel automatically tests the battery every hour and whenever you Arm Disarm the panel Dynamic Battery test Whenever an alarm occurs it may be silenced with a User Code or by optional Radio Keys otherwise it will reset at the end of Alarm Reset Time All alarms are stored in memory and may be viewed at any time by entering Memory Mode NESS D16 CONTROL PANEL USER MANUAL EN KEYPAD The Ness LCD keypad provides important visual and audible indication of the system status and is the main
14. e in the Armed state This means that Day 24hr and Monitor zones are independent of the area operations Note Area partitioning is in addition to Monitor Mode Any zone may be allocated to any area EN NESS D16 CONTROL PANEL USER MANUAL ARMING YOUR ALARM SYSTEM m ARMING 1 The NOT READY light must be off 2 Press User Code E JJJ OF Jd If Arming Shortcut has been enabled by your installer or by RADIO KEY press the ON button 3 The ARMED light will turn on Leave the premises within the Exit Delay Time Atthe end of Exit Delay Time 3 beeps will sound The control panel must be Armed prior to vacating the premises in order to detect intruders Ensure that the panel is not in Program Memory or Exclude modes Note If the panel is already in alarm you must first silence the alarm before you can Arm If something is wrong when Arming the control panel the normal 3 beeps will be replaced by other warnings 2 10 10 beeps means Mains Power is turned off or the Backup Battery is low 4 One long beep indicates an invalid entry oran alarm is outstanding and needs to be reset by entering your User Code first SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds as a warning to indicate that those zones have been automatically excluded For maximum security you should return Disarm check the premises
15. ed by the same key sequence as Disarming the panel If you arrive at your premises and find the strobe light flashing if installed reset the panel as above To check the cause of the alarm you can view the alarms in memory by entering Memory Mode EJ NESS D16 CONTROL PANEL USER MANUAL MONITOR MODE r MONITOR MODE 9 JJ 2 Press User Code E JJJ If Monitor Shortcut has been enabled by your installer or by RADIO KEY press the OFF button twice If Radio Key Monitor Arming has been enabled by your installer 3 The MONITOR light will turn on Only the zones which have been programmed by your installer to be Monitor Zones will be Armed Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home Your installer must program which zones will be active in Monitor mode The panel must be fully Disarmed before Arming in Monitor Mode If an alarm occurs while in Monitor mode entering User Code E will silence the alarm This will also Disarm the panel so remember to enter monitor again if needed By using the optional Radio Keys you can enter Monitor Mode by pressing the OFF button twice within 4 seconds Your installer must enable Radio Key Monitor Arming for this to work NESS D16 CONTROL PANEL USER MANUAL E EMERGENCY FUNCTIONS r PANIC or Cx E
16. entified by entering the Alarm Memory Mode as described on page 14 ES NESS D16 CONTROL PANEL USER MANUAL Alarms may be caused by Azone has been triggered while Armed ATamper has been triggered A PANIC button has been triggered INSTALLATION RECORD Date purchased Date installed D 4 1 6 Installation Company DIALLER SECURITY ALARM PANEL Telephone NESS D16 ALARM CONTROL PANEL Monitoring Company Telephone ZONE LIST DEVICE TYPE DESCRIPTION Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 NOTES 2001 Ness Security Products NESS D16 CONTROL PANEL USER MANUAL EJ OPERATION SUMMARY To ARM the system To DISARM or reset alarms User Code E OF E User Code E To Arm MONITOR mode To exit MONITOR mode User Code E Or E User Code E To EXCLUDE zones then To exit EXCLUDE mode User Code E OF E ZONE NUMBER E ZONE NUMBER E Up to 16 zones E PANIC alarm Cx User Code E 0r Cx E Of Cx Cx together To view MEMORY To exit MEMORY mode E NESS D16 CONTROL PANEL USER MANUAL User Code E OF E JIJ The next most recent event will be displayed Press Giewory and so on Up to 30 eve
17. ke sure the plug pack is plugged in and the power point id turned on Replace the backup battery Call your installer 1 long beep from keypad Invalid keypad entry Press E button and try again 2 second siren at the end of Exit Delay time A zone was Unsealed at the end of Exit Delay time Disarm the panel and check all zones Strobe light is flashing There has been an alarm Reset the alarm by Disarming the panel and check the Alarm Memory Siren sounds while the panel is Disarmed A 24 hour zone has been triggered E g Siren Tamper Box Tamper Panic Button Reset the alarm by Disarming the panel and call your installer EXCLUDE light is flashing A zone s has been Excluded TAMPER light flashing The 24 hour Tamper input has triggered Call your installer ALARM MEMORY light is flashing There are alarms in memory To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you Arm the panel Cannot enter Program Mode ALARMS DEFINITION The panel is Armed Only the Master Code can enter Program Mode Disarm the panel before attempting to enter Program Mode Try again using the Master Code All of these may cause your sirens and strobe to operate Various visual indications relevant to the alarm will be retained in the memory If this occurs Disarming your control panel will reset the alarm The cause of the alarm can be id
18. modes if you do not press any buttons on the keypad in a 4 minute period If you make a mistake while entering any codes press the enter button and start again When you are required to enter your access code you are given five opportunities to enter it correctly After the fifth invalid attempt the alarm is activated requiring the correct code to silence the alarm This prevents anyone trying to guess your code by entering random numbers AREA OPERATION Area Partitioning allows the 16 zones to be split into two partitions Areal and Area2 The panel then effectively operates as two separate systems sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Area and Area2 are both Armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Areal or Area2 Disarms OPERATION Arming and Disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they ar
19. nts
20. rtcut has been enabled by your installer 2 The EXCLUDE light will turn on 3 Enter the zone number of the zone s to be Excluded ZONE NUMBER E ZONE NUMBER E Up to 16 zones The zone light of each Excluded zone will turn on 4 Press E to exit Exclude Mode 5 The EXCLUDE light will flash continuously If a detector becomes faulty and cannot be Sealed when arming the panel then its zone may be Excluded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously while the panel is Disarmed and also when Armed Zones can only be Excluded when the panel is Disarmed Zone Exclude IS not permanent Excluded zones are automatically INCLUDED next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the ZONE NUMBER E sequence to turn OFF the zone lights to be Included NESS D16 CONTROL PANEL USER MANUAL E ALARM MEMORY or JI r VIEW ALARM MEMORY 1 Press User Code JJJ If View Memory Shortcut has been enabled by your installer 2 Press The next most recent event will be displayed Press The next most recent event will be displayed Press Ciemory and so on Up to 30 events 3 Press to exit Memory Mode 4 The MEMORY light will stop flashing The D16 Control Panel stores a comprehensive Alarm Memory The D16 will remember Arming Disarming Low Battery Main
21. s Fail and Alarms The memory is constantly upgraded and the last 30 events are always available for viewing This Memory display can only be selected while the panel is in the Disarmed state TO CLEAR THE MEMORY LIGHT The MEMORY light flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY light stops flashing after the memory is viewed as shown above The MEMORY light is automatically cleared next time the panel is Armed MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS LIGHT ALARM EVENT Zone lights 1 16 Zone alarm ARM Panel Armed no lights Panel Disarmed TAMPER Tamper alarm Siren cover panel etc EXCLUDE Panic alarm BATTERY Low Battery MAINS Mains power failure RADIO BATTERY ZONE RADIO BATTERY ARM Radio Device battery low Radio Key battery low E NESS D16 CONTROL PANEL USER MANUAL PROGRAMMING Various system options as listed below can be programmed by the user These options can only be accessed from Program Mode User Codes may need to be re programmed if a person has forgotten their code to give a new user access to the system or to give someone temporary access User Codes 2 15 can be set as Arm Only Codes These codes can Arm but cannot Disarm the panel Useful for assigning to cleaners tradesmen etc You may need to change the Entry and Exit timers if you find the delays are too long or short If Audible Monitoring is programmed b
22. supply conditions Monitor Mode Home Mode Outputs are separately fused with Automatic Reset Fuses Day Mode and Door Chime feature Zone inputs can be split with two end of line resistors so that two detection devices ie reed switches can both be monitored to provide maximum Security 30 Event Memory Supports 16 Radio Devices Radio PIRs Radio Reeds etc Supports 14 Radio Keys All inputs and outputs are heavily protected against lightning and high voltage supply transients An earth terminal is provided for extra protec tion 15 User Codes Arm only codes can be programmed Programmable Inputs to activate selectable Outputs Designed utilising the latest SMD Technology Forced Arming Feature Simple to Program and Use ES NESS D16 CONTROL PANEL USER MANUAL INTRODUCTION The Ness D16 micro computer based 16 zone control panel is the heart of your security system to which all your detection devices connect Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be connected to the D16 control system directly by cabling or with optional wireless Radio devices Detection devices called Passive Infra Red Detectors or P I R s for short can detect the movement of an intruder by sensing their body heat P I R s are used to cover various critical areas of your premises where an intruder may enter or trespass
23. using the Primary and Secondary telephone numbers When Audible Monitoring is enabled the Follow Me Telephone Number is available and can be programmed in User Program mode See page 17 for information on programming the Follow Me Telephone Number AUDIBLE MONITORING SEQUENCE When triggered by an alarm the D16 will dial the programmed telephone number s and output the audible message for 45 seconds or until it is acknowledged ACKNOWLEDGING THE ALARM The person receiving the call can then acknowledge the alarm by pressing the key on their telephone Press the key for at least 2 seconds during pauses in the audible message If the alarm is not acknowledged the keypad s LINE light will flash continuously until the panel is next Armed The programming of Primary and Secondary phone numbers is an Installer Programming option The Follow Me Telephone Number replaces the Primary AND Secondary telephone numbers NESS D16 CONTROL PANEL USER MANUAL 19 REMOTE OPERATION OPERATING THE D16 BY TELEPHONE The D16 will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2 To ensure security of operation a user can only carry out remote operations after entering a valid user code REMOTE CONTROL FUNCTIONS NEED Atelephone with DTMF tones AValid User code programmed in the D16 TheTelephone number
24. xit Program Mode P then E Selects a program The current value Enter new KEY option address is displayed data SEQUENCE l i EA ani DOLG JI os asyay he OLVG JII MODE PROGRAM button 2 or 3 Digit Option 00 to 119 ENTER button Enter new value using keys 0 9 ENTER button r PROGRAMMING USER CODES 1 Press P MASTER CODE E BE Enters Program Mode The PROGRAM light will turn on 2 Press P O O E ad The existing code will be displayed by the keypad lights Enter the Option Number of the User Code to be programmed See Options Table 3 Press 0C COGO JOOO0U dd Enter the new User Code twice 4 Press P then E JJJ To exit Program Mode The PROGRAM light will turn off EXAMPLE 1 To program User Code 1 The Master Code MOOD JII COCOCOCOGD J OVLVVVG JJ L Enter the new code Enter new the code again EXAMPLE 2 To program User Code 2 as an ARM ONLY code MOOS JI WD COCOCOCOGD J OOOO JIJ Enter the new code Enter new the code again 16 NESS D16 CONTROL PANEL USER MANUAL PROGRAMMING PROGRAMMING ENTRY EXIT TIMERS 1 Press P MASTER CODE E JJJ Enters Program Mode The PROGRAM light will turn on 2 Press P CJ P E Jd The existing time will be displayed by the keypad lights Enter the Option Number of the Timer to be programmed See Options Table 3 Press 5 JJJ Enter the new time from 1 99 seconds 4
25. y your OPTION OPTION No User Code 1 Master Code FACTORY DEFAULT installer the Follow Me Telephone Number is the telephone number the dialler will call in the event of an alarm If your Ness D16 panel is monitored by a Central Station the Follow Me number is ignored For all other programming changes talk to your installer The panel will automatically exit Program Mode is no buttons are pressed within a 4 minute period To enter Program Mode P MASTER CODE E To exit Program Mode P then E PROGRAMMED 3 to 6 digi User Code 2 3 to 6 digi User Code 3 3 to 6 digi User Code 4 3 to 6 digi User Code 5 3 to 6 digi User Code 6 3 to 6 digi User Code 7 3 to 6 digi User Code 8 3 to 6 digi User Code 9 3 to 6 digi User Code 10 3 to 6 digi User Code 11 3 to 6 digi User Code 12 3 to 6 digi User Code 13 3 to 6 digi User Code 14 3 to 6 digi User Code 15 Entry Delay 1 20 seconds 3 to 6 digi 1 to 99 sec Entry Delay 2 60 seconds 10 to 990 sec Exit Delay 60 seconds 1 to 99 sec Follow Me Telephone No Up to 15 digits NOTE The Entry Delay 2 timer programs in 10 second intervals Example if a value of 6 is programmed the time is 60 seconds NESS D16 CONTROL PANEL USER MANUAL I3 PROGRAMMING To enter Program Mode P MASTER CODE E To E
Download Pdf Manuals
Related Search
Related Contents
Chargeur & Batterie du Multi Outils EMO 36 Ficha técnica BTL-08 LC ECG User Manual Training and Education Services, IST Division Instalación - Bosch Security Systems SDMN6 - Fieldpiece Instruments PX0210 User Manual www.truemfg.com TENSOGEL HIDROALCOHÓLICO SLH 090 - Jungheinrich Copyright © All rights reserved.