USER GUIDE Dew Point Temperature Detector MODEL IRT600
Contents
1. EXTECH USER GUIDE INSTRUMENTS Dew Point Temperature Detector with Laser Pointer MODEL IRT600 Introduction Congratulations on your purchase of the Model IRT600 Dew Point Temperature Detector The IRT600 is capable of displaying Air Temperature AT Surface Temperature ST Relative Humidity RH and Dew Point Temperature DP and can analyze the potential for mildew The LED lamp above the LCD display changes color to indicate the potential for mildew green no mildew yellow or amber low to moderate probability of mildew and red high probability of mildew The IRT600 measures Surface Temperature using an infrared IR sensor and includes dual red laser pointers for improved targeting The IR sensor has a 12 1 Distance to Spot ratio This means that a target 30cm away from the meter has a spot diameter of 1 25cm a target 45cm away has a spot diameter of 3 75cm and so on The closer to the target the smaller the spot size and the further away the larger the spot size very much like a flashlight beam behaves with regard to distance to spot ratio The Air Temperature and Relative Humidity are measured by the internal sensors at the top of the meter Dew Point Temperature is calculated using Air Temperature and Relative Humidity measurements Mildew analysis is based on calculations made from Air Temperature Surface Temperature Dew Point Temperature and Relative Humidity values This meter is shipped fully tes
2. there is a low to moderate potential for mildew If the surface temperature lies within the bottom third temperature range between the air temperature and the dew point temperature the LED will be red indicating that there is a high probability of mildew present on the surface under test For example if the air temperature is 25 C and the relative humidity is 50 the dew point temperature is 13 8 C In this example the light would be green when the surface temperature is between 25 and 21 3 C a yellow light would indicate a surface temperature between 21 2 and 17 4 C and a red light would indicate a surface temperature between 17 3 and 13 8 C Battery Replacement To replace the battery 1 Open the battery cover located on the handle grip 2 Carefully remove the battery 3 Install new 9V battery 4 Close the battery cover before using the meter Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment Battery Safety Reminders o Never dispose of batteries in a fire Batteries may explode or leak o Remove battery
3. pointer button switches the pointers ON or OFF The IR sensor has a 12 1 distance to spot ratio see accompanying field of view diagram For example at a 30cm distance the measured spot size is 2 5cm 30cm 12 2 5cem 4 Press the trigger firmly again to switch the meter OFF 15cm 6 IR Surface Temperature Measurement Notes 1 25cem G 1 The object under test should be larger than the spot target size calculated by the field of view diagram printed on the side of the meter and in this guide 2 Before measuring be sure to clean surfaces that are covered with frost oil grime etc 3 If an object s surface is highly reflective apply masking tape or flat black paint to the surface before measuring Allow time for the paint or tape to adjust to the temperature of the surface it is covering 4 Measurements cannot be made through glass 5 Steam dust smoke etc can obscure measurements 6 The meter automatically compensates for deviations in ambient temperature However it can take up to 30 minutes for the meter to adjust to extremely wide changes 7 To find a hot spot aim the meter outside the area of interest then scan across in an up and down or side to side motion until the hot spot is located Detecting Mildew To detect mildew take a Surface Temperature measurement as described earlier by pointing the meter at the desired object s and moving the meter slowly noting the surface temper
4. ature of the object s under test Also note the Air Temperature Dew Point Temperature and Relative Humidity to learn how these relationships affect mildew potential The meter automatically detects the likelihood of mildew nonetheless it is useful to see how one measurement affects another and how the combinations of these measurements and calculations lead to an accurate mildew analysis The likelihood of mildew is higher the closer the Surface Temperature is to the Dew Point Temperature The Dew Point temperature takes the Relative Humidity measurement into account since the higher the RH the higher the Dew Point Temperature The meter uses the Air Temperature AT and the Dew Point Temperature DP values to create a range of temperatures that is divided into thirds see accompanying diagram The upper boundary is the Air Temperature AT and the lower boundary is the Dew Point Temperature DP Air Temperature AT Green Yellow Red Dew Point Temperature DP 5 IRT600 EU EN v1 4 9 13 If the surface temperature lies within the upper third temperature range between the air temperature and the dew point temperature the LED will be green indicating that the surface temperature and humidity are both normal and mildew is unlikely see diagram If the surface temperature lies within the middle third temperature range between the air temperature and the dew point temperature the LED will be yellow amber indicating that
5. from meter if it is to be stored for a long time period 6 IRT600 EU EN v1 4 9 13 Specifications Main Display Three color LED indicator Response time Diode Laser Pointers Emissivity IR Spectral Response IR Sensor Field of View Operating temperature Storage temperature Relative humidity Power supply Weight Dimensions Backlit LCD with multi function indicators Green Amber and Red to indicate mildew potential lt 1 second Output lt 1mW Wavelength 630 670nm Class 2 II Laser product 0 95 fixed 8 14um 12 1 Distance to Spot Ratio 0 C to 50 C 32 F to 122 F 20 C to 60 C 4 F to 140 F 10 90 RH operating lt 80 RH storage 9V battery NEDA 1604A or IEC 6LR61 or equivalent 163g 5 7 oz 168 x 82 x 58 mm 6 6 x 3 2 x 2 3 Range Resolution Accuracy Air Temperature 50 to 350 C 58 to 662 F 0 1 F C 3 5 C 6 3 F Surface temperature 50 to 350 C 58 to 662 F 50 to 20 C 58 to 32 F Dew Point Temperature 30 to 100 C 22 to 212 F 1 rdg 1 5 C 2 7 F 20 to 350 C 32 to 662 F Relative Humidity 0 to 100 0 1 3 5 20 to 80 Note Accuracy is given at 64 F to 82 F 18 C to 28 C lt 80 RH Copyright 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com 7 IRT600 EU EN v1 4 9 13
6. owering the Meter Press the trigger once to power the meter ON or OFF Turn the Backlight On Off Press the backlight laser button to turn the backlight on or off Selecting C F units of measure Press the C F key to select the desired temperature unit of measure Turn the Two Red Laser Pointers On Off Press the backlight laser button to turn the laser pointers ON or OFF Taking Measurements The IRT 600 can display Dew Point Temperature DP Air Temperature AT Infrared Surface Temperature ST and Relative Humidity RH The bottom display digits always show the Surface Temperature reading The upper display digits alternately show Air Temperature Dew Point Temperature or Relative Humidity depending on the mode that is selected The multi color status LED light located above the LCD display changes color to indicate the likelihood of mildew see the Detecting Mildew section 1 Press the trigger once firmly to switch the meter ON 2 Use the MODE button to select Air Temperature Dew Point Temperature or Relative Humidity for the upper display digits The meter will remember the display selection after the meter is switched OFF i I 3 For Surface Temperature measurements point the meter I l toward the surface under test The lower display digits show 45cm nN 18 the temperature of the surface under test For precise 3 75em J 15 targeting use the dual red laser pointers the backlight laser m
7. ted and calibrated and with proper use will provide years of reliable service Please visit the website www extech com for the latest version of this User Guide Customer Support and information on other products offered by Extech Instruments and FLIR Systems Safety e Use extreme caution when the laser pointer beam is on e Do not point the beam toward anyone s eye or allow the beam to strike the eye from a reflective surface CAUTI 0 N e Do not use the laser near explosive gases or in either LASER RADIATION potentially explosive areas DO NOT STARE INTO BEAM e Do not clean the laser with any corrosive acids or liquids DIODE LASER lt 1mW Output at 675nm e Use an appropriate 9V battery to power the meter CLASS II LASER PRODUCT 2 IRT600 EU EN v1 4 9 13 Meter Description Multi color mildew status indicator LCD display MODE button Backlight and Laser pointer button Battery compartment Measurement trigger Temperature units button Laser Pointers and Infrared sensor 1o opo ORE De GU ewe N Humidity Temperature sensors Display Description Emissivity setting fixed at 0 95 2 4 Air Temperature icon 1 Laser Pointer ON icon Battery status Bargraph range maximum 100 RH Air Temperature or Dew Point reading Unit of measure Surface temperature reading Or SO Oy S Bargraph an o Bargraph range minimum 0 10 3 IRT600 EU EN v1 4 9 13 Operation P