Home
PSACH 04244 - Modern Alarm Kft.
Contents
1. Pulsar PSACH 04244 v 1 1 PSACH 24VAC 44A 4x1A HERMETIC AC power supply for CCTV EN Edition 3 dated 10 10 2011 Replaces edition 2 dated 14 07 2011 Hee Ce CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of elements and connectors of the power supply 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Procedure of installation 3 Signalling the operation of power supply 3 1 Optical signalling 3 2 Technical output 4 Service and operation 4 1 Overload and short circuit 4 2 Maintenance 1 Technical description 1 1 General description AC AC PSACH 04244 power supply is using for supply devices requiring AC voltage of 24 V with overall efficiency of 4A 24 V AC Basic features of the power supply e 4 outputs protected independently with fuses or PTC failure short circuit within the circuit of any of the outputs will result in burnout of the safety device insert actuation of the PTC and isolation of the circuit from power supply e regulation of the output voltage in case of installation where significant drops in voltage in effective resistance of receiver supply cables can occur it is possible to correct the value of output voltage with the help of U1 U2 jumper independently for each AUX output optical work signalling informing about the condition of outputs and or failure AW technical output informing about output failure activity of the
2. SCP used for remote control of the activity protection short circuit protection SCP overload protection OLP overheat protection of the transformer OHP IP65 ABS hermetic casing equipped with microswitch TAMPER signalling opening of the door front Information about additional elements of PSACH 04244 power supply module of the AC AC power supply in ABS casing MSC 1512 module of MSC 12V 1 5A or 24V 1A power supply exchanged voltage allowing to create a 24 V AC and 12 V DC 24 V DC supply system Information about types Model S o Depo O SO PSAC 04244 AC AC 24 V AC power supply with overall current efficiency of 4 A 24V and switched output voltage of 24 0 V 27 0 V Equipped with AUX outputs condition signaling panel IP20 metal casing with signaling panel equipped with TAMPER microswitch PSAC 08246 AC AC 24 V AC power supply with overall current efficiency of 6 A 24V and switched output voltage of 24 0 V 27 0 V Equipped with AUX outputs condition signaling panel IP20 metal casing with signaling panel equipped with TAMPER microswitch PSACH 04244 AC AC 24 V AC power supply with overall current efficiency of 4 A 24V and switched output voltage of 24 0 V 27 0 V Equipped with AUX outputs condition signaling panel ABS IP65 casing equipped with TAMPER microswitch 1 2 Block diagram fig 1 E u Fig 1 Block diagram of the power supply 1 3 Description of elements and connectors of the power sup
3. solely within the service point of the producer 9 Warranty does not cover faults of the device resulting from reasons not lying within the power of the producer mechanical failures improper storage and transport usage not compliant with the user manual or the anticipated use of the device random events including atmospheric discharges power line failure fire flooding influence of high temperatures and chemical agents improper installation and set up not compliant with principles included in the user manual 10 Statement of performing changes in construction or repairs performed outside the service point of the producer or when the serial numbers or warranty stickers on the device were anyhow damaged shall result in the loss of warranty rights 11 Responsibility of the producer towards the purchaser shall limit to the value of the device settled according to the determined wholesale price suggested by the producer from the date of purchase 12 Producer shall bear no responsibility for faults resulting from damaging improper activity or impossibility to use the device especially when the above results from non observance of recommendations and requirements included in the user manual or use of the device Pulsar K Bogusz Sp j Registered partnership Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar p http www pulsar pl
4. 1 Pulsar K Bogusz Sp j producer provides two year quality warranty for the device counting from the date of sale indicated on the bill of sale 2 In case when there is no bill of sale when filing the claim three year warranty period shall be counted from the date when the device was manufactured 3 Warranty shall cover free repair or provision of functional equivalent the producer shall select the equivalent of the faulty device due to reasons lying in the domain of the producer including production and material faults unless these faults have been filed within the warranty period point 1 and 2 4 Device falling under warranty period should be delivered to the point where it was purchased or directly to the seat of the producer 5 Warranty covers complete devices with written description of the fault on properly filled claim application form 6 When a claim shall be positively considered the Producer shall be obliged to realise warranty repairs in the shortest possible time however this period of time should not extend 14 working days from the date when the device was delivered to the producer s service point 7 Repair period of which mention has been made in point 5 may be prolonged in case of lack of technical possibilities to perform the repair and in case of device conditionally accepted to the service point as the claimant did not meet the warranty conditions 8 All service activities resulting from the warranty shall be performed
5. able 6 The power supply should work in horizontal or vertical position Before installation is started the balance of the power supply load shall be performed During normal operation the sum of the currents consumed by the receivers cannot exceed I 4 0A 24 V AC Because the power supply was designed for continuous work it is not equipped with supply switch hence it is essential to ensure proper overload protection in the supply circuit It is also necessary to inform the user about the manner of disconnecting the power supply from the network supply usually by isolating and determining proper fuse element in the fuse box Electric installation should be performed according to binding standards and regulations 2 2 Procedure of installation 1 Before initiating the installation it is necessary to ensure that the voltage in the 230 V power circuit is disconnected 2 Mount the required seals in the power supply casing taking into consideration the cross section of the feeding conductors and consumerss Additionally it is necessary to consider the location of the power supply and elements of the additional equipment 3 Mount the power supply in the selected place and guide connecting cables 4 Connect the power cables 230 V AC with L N power supply terminals Connect the earth cable to the terminal marked with earthing symbol The connection should be performed with 3 core cable with yellow green PE protecting conductor Power conduc
6. ly are protected against short circuits with fuse element safety device inserts or PTC In case of damaging fuse element safety device it is necessary to exchange the fuse compliant with the original If PTC polymer fuses protection was chosen then automatic disconnection of the output voltage was signalled by switching off the green diode It is then necessary to disconnect the load from the power supply output for the period of about 1 min Loading the power supply with the current exceeding 24 0A 24 V AC 110 150 of the S power results in the failure of the fuse F in the 230 V AC circuit and or F1 F4 fuses In case of failure it is essential to exchange the fuse compliant with original 4 2 Maintenance All maintenance procedure may be performed after disconnecting the power supply from the power network The power supply does not require performing any special maintenance procedures however in case of significant drop of the dustiness it is only essential to remove the dust from the interior with the help of compressed air In case of changing the fuse it is essential to use substitutes compliant with the original parts recommended WEEE MARKING The used electric and electronic device may not be thrown out together with common household wastes According to WEEE directive binding within the EU in case of used electric and electronic devices separate means of utilization should be utilized GENERAL WARRANTY CONDITIONS
7. ply table 1 table 2 fig 2 fig 3 A Description of LB4 24V 27V AW elements fig 2 L1 L4 LED diodes green signalling the status of LL AUX1 output etc F1 F4 fuses in AUX cicuits F1 AUX1 etc circuits Jumper of the AUX output voltage change independently for each output U2 Ut A U2 jumper used voltage on AUXx U2 output U2 U1 a U1 jumper used voltage on AUXx U1 output Table 1 LB4 24V 27V AW terminals and elements fuse block O U Oo B Jumper of the change in PTC fuse element safety device type FPX FXX 7 d Fx jumper used polymer safety device selected Fx Fx x E Fx x jumper used fuse element safety device selected 160 mm SS a a a a 145 mm _ me m mm p4mm Unux U2 33mm Fig 2 View of the LB4 24 27 AW fuse block Femen No Description Fig 3 Separating transformer LB4 24V 27V AW fuse block table 1 TAMPER anti sabotage protection contact NC F fuse in supply circuit 230 V AC L N connection of 230 V AC power supply PE protection connection Table 2 Elements of the power supply U2 Orma LIE L2 He ie iii iei io F1 u1 F2 U1 FS U1 u1 Lo a x 3 a LB4 24V 27V AW F1 F2 F pa SS i J O AUX1 COM AUX2 COM AUX3 COM AUX4 COM AW GND POM U1 U2 126 mm 160 mm Fig 3 View of the power supply 1 4 Technical pa
8. rameters electrical parameters table3 mechanical parameters table4 user Safety table5 operation parameters table6 Electrical parameters table 3 Supply voltage Supply frequency S power supply power Power consumption Output voltage U1 23 0 28 0 V AC 100 load 0 load U2 25 5 31 5 V AC 100 load 0 load Range of voltage setting U1 U2 jump change Range of voltage regulation AUX output power 4x 1A 24 0 A 24 V AC max or 23 7 A 27 V AC max 4x F 1 0A fuse element safety device or PTC 1A Short circuit protection SCP failure of the fuse element safety device requires changing the fuse element insert AC 24 V circuit 4x F 1 0A or PTC 1A AC 230V circuit 1x T 1 0A Overloading protection OLP Technical outputs AW output signalling failure of one of the AUX outputs activation of the safety device type OC 50mA max normal status L level 0 V failure status hi Z level TAMPER output signalling opening of the power microswitch NC connectors closed casing supply casing 0 5A 50 V DC max Optical signalling LED diodes L1 L4 green status of AUX1 AUX4 outputs normal status illuminated failure status not illuminated LED diode Law red failure signalling of min one AUX output normal status not illuminated failure status illuminated T 1A 250 V F1 F4 fuse F 1A 250 V or PTC 1A Mechanical parameters table 4 Connections Supply 0 63 2 50 AWG 22 10 Outp
9. tatus of operation Presence of voltage on power supply outputs is signalled by illumination of green LED diodes on LB4 24V 27V AW fuse block Failure is signalled by red LED diode AW Condition of the power supply may be controlled remotely by AW technical output 3 1 Optical signalling e LED L1 L4 green diodes signal the feeding status on AUX1 AUX4 outputs In case of loss of voltage on the output burnout of the fuse activation of the PTC appropriate LED diode stops to be illuminated L1 for AUX1 L2 for AUX2 etc e LED AW red diode indicates failure of at least one AUX output number of the output is signalled by the green diode 3 2 Technical output The power supply is equipped with signalling output enabling to submit information about the failure or sabotage e AW output signalling the activity of the fuse output of the LB4 24V 27V AW fuse block AW technical output during the proper operation of LB4 24V 27V AW fuse block is disconnected from mass GND whereas in case of damaging one of the fuses the output shall be disconnected from the mass This status is also signalled by the red Law diode e TAMPER output signalling opening of the power supply casing output of the potential free contact signaling the status of the power supply doors power supply closed NC power supply open NO 4 Service and operation 4 1 Overload and short circuit of the power supply output Outputs of the AUX1 AUX4 power supp
10. tors should be connected to proper terminals through seal wire The circuit of the shock protection shall be performed with a particular care i e the yellow and green protection wire of the power cable shall be connected from one side to the terminal marked by the symbol of in the casing of the power supply Operation of the power supply without the properly made and fully operational circuit of the shock protection is UNACCEPTABLE It can result in failure of devices and electric shock 4 Connect the cables of the consumers to the AUXx COM terminals on LB4 24V 27V AW fuse block 5 When necessary connect device cables alarm unit controller signaller etc to technical outputs of the power supply AW output signalling the activity of the fuse output of the LB4 24V 27V AW fuse block TAMPER output signalling opening of the power supply casing 6 In case of installation where significant drops in voltage in effective resistance of receiver supply cables can occur it is possible to correct the value of output voltage with the help of U1 U2 jumper independently for each AUX output 7 Connect 230 V AC power supply 8 Check optical signalling of the power supply operation LED L1 L4 diodes green should be constantly illuminated 9 Close the casing after installing and verifying the correctness of the power supply activity 3 Signalling the operation of power supply The power supply is equipped with optical signalling the s
11. uts 00 41 1 63 AWG 26 14 TAMPER output cables 30cm The casing is equipped with disassembled assembly fuse block with power supply systems User safety table 5 PN EN 60529 2002 U protection degree IP65 required assembly of seals P9 0 4 8mm x 5 items P13 5 0 6 12mm x 1 item Insulation electric strength between the input network circuit and output circuits of the power supply I P O P 3000 V AC min between the input circuit and the PE protective circuit I P FG 1500 V AC min between the output circuit and the PE protective circuit O P FG 500 V AC min between the input circuit and the output or protective circuit 100 MQ 500 V DC Operation parameters table 6 Operating temperature 10 C 40 C Storing temperature 259C 60 C Relative humidi 10 90 Vibrations during operation unacceptable Surges during operation unacceptable Direct exposure to sunlight unacceptable Vibrations and surges during transport According to PN 83 T 42106 2 Installation 2 1 Requirements AC AC power supply shall be mounted by the qualified installer having appropriate required and necessary for a given country permissions and qualifications for connecting operating 230V AC installations and low voltage installations The device should be mounted in closed rooms according to II environmental class with air humidity of RH 90 maximum and the scope of temperature within 10 C and 40 C t