Home
go1984 User manual
Contents
1. 8 3 iPhone Client The go1984 web server provides a special interface for the iPhone This offers you the chance to access the go1984 server via the go1984 iPhone client You can also establish a connection to the go1984 server both via a WLAN and via GPRS Edge This provides you with access to live images from all the cameras on the go1984 web server which you have the relevant access rights for Call up the web interface in your browser by using the following URL http ip port Replace the variables as follows by the IP address or domain name of the computer running go1984 port by the port defined in the webserver configuration default is 80 To change camera select one from the camera list Office LovelQne 1040 Parking Kitchen Serverr um Entrance 2 O 2000 2009 logiware gmbh 69 901984 User manual Webserver Each camera gives you access to the entire recordings archive You can use this simply to browse through the scenes available for a particular day or select another day To help you find the relevant scene quickly a preview is displayed for each recording When you select the scene you want it starts playing Mar 14 00 Te more en If it is a PTZ camera you can insert transparent buttons next to the relevant camera so that you can pan tilt and zoom the camera via the touch sensitive display 2000 2009 logiware gmbh Webserver 70
2. 2000 2009 logiware gmbh 33 901984 User manual Basic setup 6 2 6 Export Recordings are saved in a proprietary format However the scenes recorded may be exported in AVI format or individual images in JPEG format E E Administrator 4 3 Cameras a IP Cameras Set My camera namane ln a Export an individual image Y E Motion detection Eff Recording 2 5 Mai2008 ES 28 Mi Export a scene When you are exporting to AVI format you will be offered the codecs available on your system to choose from when it comes to video compression Compressor Full Frames Uncompressed Microsoft Video 1 Intel YUV codec Intel YUV codec 2000 2009 logiware gmbh Basic setup 34 6 3 Motion detection 901984 includes high performance motion detection based on an optimized image difference process When motion detection is triggered the so called Motion signal is activated for this camera This signal can be used for instance to begin recording to launch an FTP upload or to trigger an alarm The image is split for this purpose into 8x8 pixel segments which are each analyzed for motion This means that with a resolution of 640x480 pixels for instance 4 800 segments must be analyzed for each individual image The threshold specifies what the minimum percentage of segments needs to be where motion is detected in relation to t
3. 8 4 J2ME Client You can also use a cellular phone with Java capability supporting the MIDP2 0 standard to access 901984 More specifically you can e view motion controlled live images e switch between the different cameras e control PTZ cameras Your cellphone has to be configured in such a way that the computer on which go1984 is running is accessible via the Internet To this end you can connect using the CSD GPRS or UMTS standards If your cellphone is not pre configured for Internet access please refer to your cellphone s instruction booklet for the correct settings or contact your network provider In addition the go1984 computer has to be accessible via the Internet using a static Internet IP address or a dynamic domain name Install the go1984 applet according to your cellphone s instruction booklet You ll find the required JAD JAR files in the following directory lt InstallDir gt web wap ota lt InstallDir gt is the directory where 901984 was installed You can launch the applet directly after installing it First open the settings dialog 2000 2009 logiware gmbh 71 901984 User manual Webserver The following fields need to be completed Optional Name of the camera that is automatically displayed after the connection has been set up ODE CIN I Username Your Roan Password 2000 2009 logiware gmbh Webserver 72 After you ve completed all fields
4. If you intend to transmit the image in a different resolution or compression level to that of the original image due to a small amount of bandwidth being available you can set this via the parameters Width and Height or CompressionLevel A compression level of 100 corresponds to the image s original quality O 2000 2009 logiware gmbh Webserver 78 You can see in the screen below that no images are transmitted as long as there is no kind of movement O fps The cluster camera is therefore almost in standby mode The motion detection function can now be deactivated Then every relevant image transmitted is recorded El amp Administrator El Y Cameras de IP Cameras a El a ggg Samet a ae corina 3 Alarm management H IG I0 Hanse ni 4 4 Image center Er gt Webserver En User manager r Help doubleclick mul Note A web server session is initiated on the cluster client for every active cluster camera If the cluster server being used is a Pro edition one a maximum of two cameras can be operated in this way With a Standard edition server a maximum of one camera can be operated like this see Editions gt Webserver sessions 2000 2009 logiware gmbh 79 901984 User manual Image Center 9 Image Center The Image Center is a flexible tool for viewing one or several cameras on a screen The camera arrangement is controlled using so called views 901984
5. 23 Alarm management H A PTZ camera ES Direct X AE lO Manager AE Image center HU Webserver Ge User manager Y Help doubleclick 13406 320x240 10 4 fos 9 09 10 AM 9 06 17 AM Axis Camera 207 TAxisCameral Administrator Cameras iP Cameras My camera a re 2000 2009 logiware gmbh Additional settings 84 If you want the image to be captioned use the Caption tab This function is also only available when the button is not activated S Add to Text Format ddimmyyyy hhinn ss Fit image to visible area expand Maintain image proportions TFE Use original image from camera for best performance Flip image horizontally Flip image vertically Rotate image by 90 Rotate image by 180 Rotate image by 270 2000 2009 logiware gmbh 85 901984 User manual Additional settings You set the image record pause using the following sliders The default setting is 200 ms i e 5 images per second fps In order to avoid increasing the network load and memory requirements unnecessarily you should in this case set the actual value required rather than the highest possible value In most cases using higher image refresh rates hardly results in scenes with greater information content El E Administrator 3 Cameras a IP Cameras Fi Properties 200 ms 5 0 fps Y pe boon Es criba mJ Alarm manag
6. LYCOS POP3 Server pop lycos de SMTP Server smtp lycos de Pop Kontoname Benutzername lycos de POP3 Server pop o2online de SMTP Server mail o2online de Pop Kontoname IhreRufnummer o2online de RTL World POP3 Server pop3 rtlworld de SMTP Server smtp rtlworld de Pop Kontoname Benutzername Schlund POP3 Server pop kundenserver de SMTP Server auth smtp kundenserver de Pop Kontoname m1234567 1 Mailbox Name POP3 Server post strato de SMTP Server post strato de Pop Kontoname name eigenedomain de Partner STRATO T ONLINE POP3 Server pop t online de SMTP Server mailto t online de Pop Name Anschlusskennung T Online Nr 0001 t online de T ONLINE SMTP POP3 Server pop t online de SMTP Server smtprelay t online de Pop Name Anschlusskennung T Online Nr 0001 t online de TISCALI POP3 Server pop tiscali de SMTP Server smtp tiscali de Pop Kontoname Benutzername ohne tiscali de VODAFONE POP3 Server pop email vodafone de SMTP Server smtp email vodafone de Pop Kontoname Tel Nummer o Alias vodafon de WEB de POP3 Server pop3 web de SMTP Server smtp web de Pop Kontoname Benutzername YAHOO POP3 Server pop mail yahoo de SMTP Server smtp mail yahoo de Pop Kontoname E Mail Adresse ohne yahoo de 2000 2009 logiware gmbh Masthead 96 13 Masthead logiware TT a TI BEBEBBBBE logiware gmbh Alfred Mozer Str 42 D 48527 Nordhorn Germany Telephon
7. PI 12 21 23 PI Axis Camera 207 TAxisCamera Admin istrator Cameras lP Cameras iy camera Alarm management Notification 2000 2009 logiware gmbh 89 901984 User manual Additional settings In most cases it is sufficient to complete the fields shown in the diagram If 901984 is still not able to send e mails check the settings or test using the POP3 before SMTP authentication method To do so please complete the POP3 access data block 000 By Cameras a IF Cameras SMTP server From email address EB y camera mim Arm ES al Use authentication E POPS logon before sending mail u ee Username POPS server SAE too ore E Image center REEL HE Password POPS username C ah POPS password ic po 2000 2009 logiware gmbh Additional settings 90 10 5 Translation It is possible to integrate new languages for the interface The following table shows the available languages E Administrator EG Cameras Eu IP Zameras eu kiy camera q Motion detection fff Recording Alarm management G Direct X EJ I0 Manager oF gt Webserver i Startup Http proxy SMTP properties Sceneca che Translation Error Log Cameras Direct X Help doubleclick Image center O Manager IP Cameras If you wish to create a new language option right click on a free column in the table Select an existing language as a template A dialog box appear
8. available to you as a DirectX device The next steps are the same as in the description for webcams USB 2000 2009 logiware gmbh Ep 25 901984 User manual Basic setup y 6 2 Recording Recordings are automatically sorted by month to the respective camera in the go1984 explorer If you wish to view the recordings select the Recordings entry of the respective camera in the go1984 explorer You ll be shown a list of all the months for which scenes are available Monthly overview Selecting a month will take you to the monthly overview Days are listed vertically times of day horizontally Each scene is represented as a little red mark in this overview Moving the mouse pointer over the marks calls up a quick preview of the corresponding scene You can open the selected scene for viewing by double clicking on it e E Administrator EB My camera 11 18 47 899 B 22 Thu H Alarm management 2000 2009 logiware gmbh Basic setup 26 Daily overview If you wish to view the recordings for a specific day select the day in the 901984 explorer as described below You ll be provided with an overview over the scenes recorded on that day Here too moving the mouse pointer over a scene will display a preview Open the selected scene for viewing by double clicking on it El E Administrator Eier Cameras E u IP Cameras Timer osx ix u M
9. provides numerous templates suitable for different resolutions E E Administrator 4 3 Cameras a IP Cameras Efi My camera fdas Screens HS Webserver EY Gy User manager f Setup att A Help doubleclick First define a view by selecting the appropriate one from the list of available templates Double clicking on it creates a new view that you need to provide with a unique name E E Administrator E Cameras a IP Cameras HA My camera 5 E Direct X H a lO Manager ES Image center Ede 7 Screens HS Webserver afk Gy User manager oo Setup a gt Help doubleclick Double clicking creates anew view 2000 2009 logiware gmbh Image Center 80 You ll now be shown the newly created view in the 901984 explorer in which one or several placeholders are defined which will be replaced by the camera images later on To link a placeholder to acamera click on it using the right mouse button This calls up a menu with a list of all available cameras Select a camera from the list You also have the option of placing a graphic behind the entire view Ei E Administrator E dea Cameras E IP Cameras Background image ee U En Direct X Len E 403 10 Manager x 59 y 51 PaintBox al a Image center Fr Du Webserver ae User manager y Help doubleclick RE JE BEE TI pS u BEES e Administrator image center vie
10. the event O O 6 Enter a name for the event f Cancel 2000 2009 logiware gmbh Basic setup 40 The new signal is now available and can be activated or deactivated via the shown URLs El Administrator E 4 53 Cameras e ur Properties a lO Manager El a Event E H Camera E CERE Scheduler E a une event http 11192 163 1 53 31 external name my_event aciwe 1 z Image center a gt Webserver Er User manager http 192 168 1 53 051 external name my_event actiwe 0 2 Help doubleclick http 4192 168 1 63 5 Vexternal name my_event amp actvwe 1 amp impuls 1 The other settings are now applied directly via the web interface of the camera or motion detector Take as an example the settings for an axis camera shown below First of all the 901984 server is created as an event server Event Servers Name Protoce t Basic Configuration t Video Image t Live View Config Event e aaa Event Freee Motion Detection Port Status t System Options add FTP 2000 2009 logiware gmbh 41 901984 User manual Basic setup You can check the connection directly using the Test button Event Server Setup HTTP Server Name go1984 Server URL http 192 168 1 63 B1 external User name Administrator Password LET Proxy address Proxy port Proxy username Proxy password Test the connection
11. to the specified HTTP server Test Events can now be defined accordingly at the start and end of the movement Event Types Event Type List t Basic Configuration t Video amp Image Name status Enabl Pr t Live View Config Event Configuration Instructions arj SNE Event Types Moton Detection Port Status t System Options Add scheduled 2000 2009 logiware gmbh Basic setup 42 Enter the On URL parameter under User defined parameters for the event at the start of the motion name my_event amp active 1 Triggered Event Type Setup General Name Motion Start Priority Normal Set min time interval between triggers 00 00 00 max 23 59 59 Respond to Trigger Always Only during time frame Sun Mon iY Tue Wed Thu Fri Sat Start time 00 00 Duration 2 00 max 168 00 hours O Never event type disabled Triggered by Motion detection In window Main when motion detection starts When Triggered E Upload images F Activate output port E Send email notification Send HTTP notification to go1984_Server Custom parameters name my_event amp active Message Fi Send TCP notification to Then add a MotionEnd event which will be triggered at the end of the motion Enter the following parameters for this event name my_event amp active 0 2000 2009 logiware gmbh 43 901984 User manual Basic se
12. web interface shown in the diagram will then be displayed in your browser ogiware IE G 19a Came Grerarce al Conference 2 Levee 1046 El Carora Grand Garden Bra Support i Vivi pa u mar a e Pa RAT TA AAA AR IT eae a A nd j ree hae HEN 015 0 La to Doe fe aig dq Lep a al a de 3 Fo w ai AA LE a P ko Fr aa 1 els Hetel 2000 2009 logiware gmbh 67 901984 User manual Webserver If you ve activated the user management you ll first be shown a login request requiring you to enter a valid username and password Connect to 127 001 The server 127 0 0 1 at go1984 requires a username and password User name f Password Remember my password ul Note In order for all example webs to run correctly you may have to modify your browser s security settings If you have no Java Virtual Machine installed you can download it free of charge at the following URL http www java com If you wish to use ActiveX based webs allow the following security settings e Run ActiveX elements which are safe for scripting e Run ActiveX PlugIns and controls e Download unsigned ActiveX controls e Active scripting If you wish to use Java based webs allow the following security settings e Scripting of Java Applets e Active scripting O 2000 2009 logiware gmbh Webserver 68
13. 0 2009 logiware gmbh Editions 2 Editions 901984 is available in various editions The following figure highlights the differences g01984 features Standard Pro Enterprise Supports IP cameras Supports Direct X sources User administration Webserver sessions Pre alarm recording Post alarm recording Recording capacity Ring storage Archive access intervals Cluster server Cluster client Program start in case of alarm Telephone call in case of alarm Event management I O controlling Scheduler 2000 2009 logiware gmbh 3 901984 User manual Installation 3 Installation Installing 901984 is a matter of minutes even for users unfamiliar with the program An unregistered version of the software can be tested for 30 days with all its functions An uninstaller is included in the download so that you can remove 901984 immediately from your computer if you are not happy with the program To start the installation click on the following icon is First choose the language you want for the installation process Select Setup Language Select the language to use during the installation You will now be taken step by step through the installation process for go1984 You can accept the default settings and continue in the installation process by clicking on the Next gt button where applicable alae Eat el M J su Welcome to the 901984 Setup Petes wong Wizard Vide
14. 01721234567 Fa Notification 22 FTP Upload amp Direct X Audio format must be PCM 5 000 kHz 16 Bit Mono 1 03 IO Manager Sie Image Center f Reset CAP y f Cancel call Screens fd gt Webserver fA gy User manager amp Help doubleclick 7 u Er SS L LEN gt a Administratori Cameras lP Cameras ily camera Alarm managementiPhone call Y Motion detection 059217139925 Ey C Program Filesigo19e4 CapiVavilnto way 640x480 4 9 fps 13 15 57 PM 2 56 27 PM Axis Camera 207 TAxisCamera In order to avoid being notified too often by calls you can define a rest time that has to elapse between calls To do so click on the clock icon and set the desired rest time on it Please also refer to the general notes on activating notification functions in the section on notifications 2000 2009 logiware gmbh Basic setup 56 6 6 Scheduler go1984 provides the option of executing certain functions such as recording or notifying only at certain times You can define as many schedulers as you like which can then be linked to the corresponding functions In order to create a new scheduler select the option Scheduler in the go1984 explorer E Administrator EXA Cameras a IP Cameras el Create a new scheduler 3 eu My camera Recording E May 2008 Bg 22 Thu H E Alarm management Ep Direct X ES O HManager Fy Event You can give each schedu
15. 901984 in service mode see Installation section deactivate this option so that 901984 service will then be launched automatically E E Administrator E 3 Cameras 52 IP Cameras E My camera lus r e Motion detection E ze Recording 9 23 ea Alarm management a Direct X 03 lO MManager El Ta image center us Webserver ben oy User manager en Help doubleclick jui Note a start automaicaly when windows starts up Http proxy SMTP properties Scenecache Translation E Start 901984 minimized i Select a skin Most Windows programs are shut down completely when you close the program window 901984 is only hidden and continues to run in the background While the program is running the 901984 symbol is displayed in the task bar near the time You can use it to shut the program down completely or to bring it back to the foreground Clicking on the icon with the right mouse key will open the corresponding menu Sh re E 9 46 AM 2000 2009 logiware gmbh Entering the license code 5 Entering the license code 10 901984 runs as a demo version after being installed In order to make 901984 function without any time or feature restrictions you need to enter the activation data you purchased into the appropriate fields EM RUNE 3 E y Cameras P Cameras o Ei Direct X a lO Manager 9 22 Image center 5 wae 7 cou 24 acy Use
16. Camera Administrator Cameras P Cameras My camera larm man agementiLAN Broadcast You also again have the option here to set a rest period by clicking on the clock icon This means that only when at least the specified period between two broadcasts has elapsed can a new notification be sent Please also refer to the general notes on activating notification functions in the section on notifications If a motion is detected you will be informed via popup from now on The last images transmitted can be replayed by clicking on the Play button a ily Camera 2000 2009 logiware gmbh Basic setup 52 You can also apply other settings on the broadcast client go1964 Client soft Buttons Network Popup on new Image Startup minimized f Select Skin y Popup on new image go1984 client appears in front when any motion is detected Startup minimized go1984 client is minimized on start up Play sound on new image Choose whether and with which sound file you would like to be notified if a motion is detected Notify again after Minimum period which must elapse before the next time you are notified Number of buffered snapshots Number of buffered images max 100 Select Skin Choose one of the available skins O 2000 2009 logiware gmbh 53 901984 User manual Basic setup ss Note Most Windows pro
17. ID El a Alarm management e Datetime filename FTP directory go yywy mm dd_hh nn 85 272727 jpg A Rotating number filename sample0024 jpg RAR u A Keep connection e Direct X 20 Tl E af lO Manager z E al Image center a E Upload as tmp and rename if finished 03 Screens al E Webserver ae User manager s Help doubleciick a 9 tos 134239 PM 2 56 27 Phil Axis Camera 207 TAxisCamera Admin istratoriCa meras lP Cameras My camera Alarm managementf THU pload The Action button amp is linked by default to the NewImage signal see also Event management section This means that the FTP upload is activated every time a new camera image is generated In this case too you have the option to set a rest period by clicking on the clock icon This means that only when the period specified between two transmissions to your FTP server has elapsed can a new upload operation be launched This then allows you to have the FTP upload operation simply carried out at a set interval Please also refer to the general notes on activating notification functions in the section on notifications 2000 2009 logiware gmbh Basic setup 50 6 5 4 LAN Broadcast In the event of an alarm 901984 can notify any users on the LAN via UDP Broadcast If the 901984 client has been installed and is active users will be notified about the movement detected on a camera via popup an
18. User manual 901984 http www go1984 com Alfred Mozer Str 42 D 48527 Nordhorn Germany Telephone 49 0 5921 7139925 Telefax 49 0 5921 7139929 http www logiware de 901984 User manual Contents Table of Contents oo Ff W N 11 12 13 Introduction ununn an A ee 1 Am 2 Lc Ae APP ARENA EARER NEAR SEESRUNLERSNEESELEERERRUEIEAERSURESASCEREREEMESENEECARERNE 3 Launching the A 8 Entering the license CONO sicicianiaii ERA kn a Rn nenn 10 Basie SEUD os 13 Adding a Camera scan EEEE EERE 14 A o nn A o o A 14 PIZZA 18 Webcam 0 be nee seen ne gene ere ees een em 23 AP ie Renee Rene ee e ee er ee 24 RECON ii 25 Calculating memory require ment sici n 28 Memory Manage Melisa aio aS 29 ocene A 30 A Pe e E a 31 ACCESS NE DENOTA ee ee Rees enieiese 32 EXPO ee een ee See 33 Motion detection u een 34 A nn 39 NotWMIcCa ON une ee ee 45 OU ee ee A ee ee 46 eee ee ee 47 A REES ENERGIEN AA A AT AEA E VENAE 48 LAN BIO IACI eir EE E E E E EE O N 50 ELICA PIO GT e ee ee EE 54 A A ee 55 An a nn 56 JE AP 60 AR 62 Configuratio T ee aci oaliii 63 o o 65 IPHONE CHEDE PP PA eiserne re 68 nn PP NE Ne NENNEN E E E 70 DINBNS ia ee a euere 73 US 21 1 PAP EN EEE CEENEENENHEHRENBENAERGN 76 Mage CONTO untada delete 79 AQAIIONalSCNIMOS serorei aaa E AE RAAR 83 CANOLA o E eigenen 83 o RAP 86 PAT DP PROXY sist Riiie 87 SMTP server CONT GUTAU ON sinia a aaan 88 o AP 90 Ev
19. abeled 901984 in your Windows start menu If you prefer a different name you can change it at this point Bi Sag Ss anes rat ay SELU COolL 03 y er en ee a os eB Sole J Select Start Menu Folder Where should Setup place the program s shortcuts A Setup will create the program s shortcuts in the following Start Menu folder To continue click Next f you would like to select a different folder click Browse go 1984 English All settings needed for the installation processes are now available By clicking on the Install button the installation will be completed and the required files will be copied to your hard drive ala ieee TT 6 Setup gal984 SEES T a a ee Ready to Install Setup is now ready to begin installing go 1984 on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program Files go 1984 Setup type Custom installation Selected components go 1984 go 1984 Client Start Menu folder go 1984 English 2000 2009 logiware gmbh 7 901984 User manual Installation The installation of 901984 has now been completed The installation routine is closed when you click on the Finish button You can choose to have 901984 launched directly afterwards Sn qo1984 al 1 gt Completing the go1984 Setup Petes wees Wizard Video sur
20. and confirmed them you can build up a connection to the 901984 server by pressing Connect The image from the camera is displayed The connection to the server is maintained In order to minimize costs a new image is only sent to the cellphone if a motion has been detected Press the More key to display a list of the available cameras to which you can also switch If the selected camera is a PTZ camera you can control it using the numbers keys Preset mode on off When you press this key the letter P is displayed at the bottom right of the screen You can now control predefined preset positions of the PTZ camera using the numbers keys 1 9 Press the key again to resume manual control 2000 2009 logiware gmbh 73 901984 User manual Webserver 8 5 DynDNS In order to make 901984 accessible via the Internet you need to have either a static Internet IP address or a dynamic domain name The latter can be set up free of charge using the DynDns org service Use the following link to set up an account https www dyndns org account create html Complete the selected fields to create an account After submitting the form you ll receive a confirmation at the e mail address you provided Click on the link in the e mail to confirm your account Now you can log onto the service using your username and password in order to set up a domain name User logitest Pass Peneen Lost Password Create Account Cl
21. are already pre determined and can be changed or removed as required You can also add via the calendar additional days for the current year or for each year Make sure that the holiday planner is not activated by default as specified holidays will continue to be ignored You activate this function by selecting the Active checkbox mM oo he 7 8 J Oktober 2008 D gt D gt So Sa Ga Load from template Di Mi Do Fr re 3 10 14 15 16 17 ee E 23 29 30 31 i i E Save as template 01 01 2084 01 85 2004 63 10 2004 25 12 2004 26 12 2004 Every year Every year Every year Every year Every year O 2000 2009 logiware gmbh User management 60 7 User management User management allows you to allocate individual authorizations for access to the program interface the web interface recordings and PTZ camera control Directly after installation user management is not activated i e all functions are accessible without entering a username or password Activate user management by clicking on the corresponding option field El E Administrator IP Cameras z Direct X El Ta lO Manager El 2 mage center Er Pin Help double click After activating the user management access is only allowed after entering a valid username go1984 creates a predefined non deletable Administrator account which always owns all access rights This account can be used witho
22. asic setup 6 2 4 Pre Post alarm Usually motion triggered recording begins the instant a motion has been detected However it is sometimes desirable to extend the recording by a few seconds before or after the event To do so simply enter the desired number of seconds into the appropriate fields and then activate the function using the corresponding button 901984 uses your computer s random access memory RAM for this feature In order to avoid too much memory being reserved you have the option of restricting the size to a maximum value Storage Scene creation Pre ig Access periods Log O 2000 2009 logiware gmbh Basic setup 32 6 2 5 Access time period Access to the recordings can be limited individually per user in the user management Among other things you can permit full access no access or access to a specified time period This is where you can define the time periods valid for this camera Storage f Scene creation Pre Post recording PA Cees periods 1 Log Afterwards simply select which time periods are available for the user in the user management El E Administrator E a Cameras E IP Cameras El My camera of Pe Video Administrator Bl Haer ff Motion detection eae T __ Camera El Recording 8 BIC My camera E Alarm management a amp General 7 EN Direct X H 4 23 10 Manager E d nage center a Treeview Web
23. ator E A Cameras al IP Cameras gt E My camera ff Motion detection EH we Recording E a Alarm management sound Motification i FTP Upload LAN Broadcast E Phone call Minimize amp Maximize r Direct X E 4 03 10 Manager E a Image center if Screens P 10 Webserver ae User manager P Help doubleclick E i 5 1 tps 3 14 48 PM 2 56 27 Phil Axis Camera 207 TAxisCamer Admin istratoriCa meras P Cameras My ca mera Alarm Mana emen cael EXE Here too you have the option of defining a rest time by clicking on the clock symbol A program is only launched if the defined time has elapsed between two program launches Please also refer to the general notes on activating notification functions in the section on notifications 2000 2009 logiware gmbh 55 901984 User manual Basic setup 6 5 6 ISDN In case of an alarm 901984 can make a telephone call using an existing ISDN card Once the connection is set up the program plays a freely definable audio file to the person being called Please enter the telephone numbers using only numeric digits Other signs or spaces can disrupt the function You can record your own audio files using the Windows Audiorecorder Please make sure you ve set the right format e PCM 8 000kHz 16 Bit Mono E Administrator eens Cameras a IP Cameras EM My camera Calling party FA Recording Fy Alarm management Called party number Sound
24. cal order You can use a filter to conveniently restrict the search for the model you want You can use characters and numerics in any combination For instance the text allnet will list all the cameras that include this combination of letters in their name E Administrator Sl pa Cameras fe Direct X E ae 10 Manager E Image center fas AD Webserver Eu ae User manager u Setup Eni Help doubleclick il log wa 1 Similarly a numeric combination such as 210 or an alphanumeric filter such as 210a can be input as search terms If you select the Ptz checkbox you can limit your search to cameras with PTZ support El E Administrator E a Cameras i 5 Direct e ce 41 453 O Hanager a Image center kun r i gt Webserver kun Mae User manager 2000 2009 logiware gmbh 15 901984 User manual Basic setup You then double click on the picture of the camera model you want to add 2 Selection list If you click on the Add camera button a list appears of the supported camera providers you can choose from E Administrator E Cameras Br IP Zameras zus Direct X H E 10 Manager a Image center aft gt Webserver OGF User manager 7 Setup ay amp Help doubleclick Airlink101 Airlive Appro Arecont Vision You simply choose the model of camera you want from the list 2000 2009 logiware gmbh Bas
25. cally The mouse pointer changes to the following symbol when held over linkable functions Clicking with the right mouse button opens the menu for creating and editing links Use the Event gt Scheduler gt entry to select one of the existing schedulers which will then turn the selected function on or off E E Administrator El al Cameras E a F Cameras My camera Action Http ewent F Camera H Invers al O Manager Ey Event ee Camera Se gt cheduler Y off time 2000 2009 logiware gmbh Basic setup 58 ss Note If certain functions need to be active at exactly opposite times in this case for instance opening hours you do not necessarily need to create an extra scheduler If you right click again on a scheduler link you can reverse the scheduler E Administrator 0 3 Cameras a P Cameras a i My camera Motion detection Eb 0 Recording E43 May 200 Rename camera 5 L Eu HCA 22 Disconnect Alarm manag E Direct X Event d aa IO Manager Action er Gi Camera Sen Scheduler fl 4 offtime 2000 2009 logiware gmbh 59 901984 User manual asic setup Under the Holiday planner tab you have the option to define days that should be processed separately These definitions have a higher priority than specified week schedulers In many countries public holidays
26. camera being used supports an area a frame can be created in the image by holding the Ctrl key down which is then highlighted You need to select the camera name again to do this This function is also supported in an image center display 2000 2009 logiware gmbh 21 901984 User manual Basic setup Preset Positions You can save up to 16 camera positions for each camera To do this simply click on the position you want hbowe to Delete position Then enter a position description Event Action Preset position 2 The new position is now displayed in color and can be accessed by clicking on it Preset position 1 2000 2009 logiware gmbh Basic setup 22 If you want the position to be displayed at certain times you can link it via a right click to a scheduler created beforehand You can in fact link the position to any signal lowe to Acid Delete position If you right click on a saved position it can be deleted again Move to m Note Sometimes administrator rights are required to be able to save or delete positions for the camera O 2000 2009 logiware gmbh 23 901984 User manual Basic setup 6 1 3 Webcam USB In order to be able to use your USB webcam in go1984 first install all the necessary drivers according to the camera manufacturer s instructions Once the camera is available as a DirextX device in Window
27. configuration and displays all IP addresses to which the webserver responds It is also possible to make the computer accessible via the Internet using a dynamic domain name El E Administrator E 3 Cameras IP Cameras My camera a Motion detection en a o Recording EH J Alarm management E po PTZ camera r e Motion detection 4 9 MByte s 39 06 MBit s ea TA o Recording a El 3 Alarm management 00 255 0 0 0 192 168 1 63 200 2009 2500 0 EH 20 O Manager J 4 9 MByte s 39 06 MBit s q laf e 2 0 MByte s 15 63 MBit s Z PTZ camer 10 Byte s 0 00 MBit s AdministratoriWebserver 2000 2009 logiware gmbh Webserver 64 The web interface addresses the available cameras using a so called index This is a consecutive series of numbers which you can use to define in which order the cameras are displayed on the web interface E E Administrator E Cameras a IP Cameras A E My camera Properties Domainname Sessions E squence of camel td e Motion detection E Recording My camera 61 03 Alarm management PTZ camera A Motion detection ff Recording H Alarm management H 10 Manager 0 Byte s 0 00 MBit s You can also view information regarding the currently active and inactive connections to the webserver For instance the display indicates the session ID the starting time the time to automatic disconnection in case of inactivity the u
28. d or an acoustic signal ss Note The go1984 client should not be confused with the 901984 desktop client Unlike the latter it is not suitable for permanent live monitoring via one or more cameras or for recording images from them You can install the go1984 client on another computer by running the go1984 setup and only ticking the go1984 Client option box San on aa fie a q p y E E Select Components 901984 Which components should be installed ere 1 Select the components you want to install clear the components you do not want to install lick Next when you are ready to continue Custom installation go 1 984 10 3 MB 2 go 1984 Client 30 MB Curent selection requires at least 3 6 MB of disk space lt Back Next gt Cancel The broadcast client can then be launched via the Windows Start menu 901984 Client Help and Support Run 2000 2009 logiware gmbh 51 901984 User manual Basic setup Now activate LAN Broadcast for the cameras you want El Administrator 4 3 Cameras a IP Cameras ep My camera l cele Motion detection Blt Recording Alarm management 1000 Byte a O E Sound e a Notification Call EXE Phone call EN Direct ao IO Manager 2 4 Image center Ca Screens gt Webserver A User manager Y Help doubleclick lt A 640x480 3 9 fps 12 39 22 PM 12 38 18 PM Axis Camera 207 TAxis
29. e 49 0 5921 7139925 Telefax 49 0 5921 7139929 Internet http www go1984 de E mail sales sales logiware de E mail support support logiware de All company and or product names are trademarks and or registered trademarks or brands of the respective manufacturers We reserve the right to make technical changes and assume no responsibility for errors or omissions 2000 2009 logiware gmbh
30. e again you have the option to set a rest period which must elapse between sending two e mails by clicking on the clock icon Simply click on the clock icon and then set the rest period you want Please also refer to the general notes on activating notification functions in the section on notifications Note The Action button amp is linked by default to the 901984 motion detection function If you want to send a meaningful image as an attachment when a movement is detected you must sometimes increase the Delayed detection value under Motion detection gt Settings The delayed detection will obviously have an impact on recordings too But you can balance out this delay simply by increasing the pre alarm value accordingly 2000 2009 logiware gmbh Basic setup 48 6 5 3 FIP If you wish the images from a camera to be sent to an FTP server in addition to being stored locally complete the following dialog First enter the login data for your FTP server FTP server Domain name or IP of your FTP server e g ftp online com FTP port almost always 21 FTP user ID Username for logging on to the FTP server FTP password Password for logging on to the FTP server FTP directory FTP server subdirectory where you want the images to be saved Passive mode If your FTP server cannot be run in the active mode select this option Keep connection After uploading an image the connection to the FTP s
31. e sorted in ascending order in the bar chart according to detected motion intensity The maximum motion share indicates which percentage is relevant to the analysis The segments before this are excluded Individual segments sorted If the motion intensity of individual segments red bar now exceeds the green line in the relevant area yellow the detected motion is highlighted in the relevant segment red rectangle in the live image The green line originates from the factors Noise suppression and Max motion share The reduction in noise suppression along with the increase in the max motion share therefore result in a higher level of sensitivity in terms of motion detection 2000 2009 logiware gmbh Basic setup 38 You will also find the following set up options Analyze only every xth frame motion detection is highly processor intensive due to the image decompression required Delayed detection delay in seconds until the motion signal is triggered This may for instance be a sensible option for an e mail alert in order to send a relevant image Idle signal after duration in seconds until the idle signal is triggered For further information refer to the Event management section Motion value is greater than This control enables you to avoid motion detection being triggered by rapid extreme lighting changes such as the interior lighting being switched on or auto iris adjustment by ca
32. ement As with many other sliders you also have the option here to specify for your own convenience the value you want in an additional window which opens when you double click on Pause between two frames Pause between two frames 6066l f Cancel 5 Some additional information about the camera is displayed at the bottom of the screen MESA sag ks eae 352288 Tie fps e 43 09 16 44 ai LevelOne Bi 1010 Anda A ast motion time Typs of camera 2000 2009 logiware gmbh Additional settings 86 10 2 Startup settings You can choose to launch go1984 minimized In this case the application will not be visible at first Only the little go1984 program icon will appear next to the system clock Double clicking on the icon will open the application interface As a further option you can set go1984 to be launched automatically when Windows is started If you are operating go1984 in service mode see Installation section deactivate this option as the go1984 service is then automatically started If you don t like the selected Standard skin you can choose a different one El Administrator l Seen Cameras Fay IP Cameras EIN My camera H A Recording 6 03 Alarm management ES Direct X Af lO Manager EJ Image center oll aa Webserver oar User manager es O 8 Help doubleclick e in Admin istratoriSetup O 2000 2009 logiware gmbh Start 901984 minimized Star
33. ent ES Direct X ee lO Manager ee Image center m Note In the case of IP cameras that do not support simultaneous MJPEG and MPEG4 dual streaming or where only MPEG4 streaming is activated by default MJPEG or Dual Streaming must be specifically selected in the camera settings e g Allnet Intellinet The section Additional settings provides information on how to edit further camera parameters such as resolution frame refresh rates or panning 2000 2009 logiware gmbh Basic setup 18 6 1 2 PTZ camera If the IP camera which has been added is a PTZ camera PTZ Pan Tilt Zoom you can easily operate this via go1984 ml Note If the camera s live image appears but you cannot use the PTZ control check the settings for Host Port Username and Password under Video gt PTZ settings to see that they are correct E Administrator By Cameras a IP Cameras AB My camera Ei PTZ camera 192 168 1 138 ca E Motion detection ft Recording El Alarm management H E lO Manager Image center me Aiei ener Jri command ptzf cgi A User manager Pan 170 7 h amp Help doubleclick a O E a mei CO o i 11 18 26 A Sony SNERZZER TSonyCamera _ 2000 2009 logiware gmbh 19 901984 User manual Basic setup There are different camera control options depending on
34. ent Manage Men aviar E un a TE nase EEE ana 91 ADDENGIX AAA ee 95 PORS3 SMIP Server u un ne sinne 95 o A A A 96 O 2000 2009 logiware gmbh 1 901984 User manual Introduction 1 Introduction go1984 is software designed for professional and hassle free monitoring by closed circuit TV CCTV It sets a new benchmark in the industry it is simple to use packed with features and available at an affordable price go1984 features everything you ll ever need to carry out professional CCTV surveillance including Live monitoring Recording timer controlled motion triggered or permanent Control of PTZ cameras Notification options acoustic by e mail or by voice call via ISDN Remote access via network or the Internet Calendar functions The software works as a so called hybrid system which means it is capable of processing digital network cameras as well as analog video sources via video servers or capture cards Companies with analog video technology can use the software to assist the smart transition to the digital world while integrating their existing hardware go1984 thus makes an important contribution to protecting your investments go1984 supports the hardware of many well known manufacturers such as for instance Axis Sony JVC Panasonic Mobotix Logitech Intellinet and many others The following figure illustrates the connectivity options provided by go1984 IP Kameras Clients 200
35. erver is kept open If you prefer the connection to be shut deactivate this option You can also choose to resize images before saving them on the FTP server Activate this option and define the new size of the image using the corresponding fields Finally you can define under which names to save the file s on the FTP server Simple filename The file name is the name you enter into the field Datetime filename The file name includes the time of day The constant part of the file name has to be enclosed in quotation marks Formatting is carried out according to the following key Year Month Day Hour Minute Second Millisecond Rotating number Enter the beginning of the file name into the field A number is filename automatically added onto the end of the name it is increased by one after each successful upload After the counter reaches the defined value it is reset to 1 Older images are then overwritten Upload as tmp and If you have problems uploading the files to your ftp server you can have rename if finished the images uploaded with the extension tmp at first After the upload has been successfully completed the files are renamed to the real file name 2000 2009 logiware gmbh 49 901984 User manual Basic setup El E Administrator Eb al Cameras E E IP Cameras My camera E a T FTP server 6 Simple filename AZ Motion detection IS El 501984 jg Si we Recording FTP user
36. ervicss Ing Legal Nebees Contec 2000 2009 logiware gmbh 75 901984 User manual Webserver g01984 can now automatically update the domain name Initiate the process by providing the domain name you ve chosen your username and password and by selecting the option Automatically update DynDNS Domain Now you ll be able to access your computer from the Internet using the dynamic domain name El E Administrator 4 4 Cameras a IP Cameras a Sessions Sequence of cameras See My camera l Y E Motion detection m E 4 Recording Port 2 53 May 2008 yourdomain dyndns org m 22 Thu Use Domain for local network connection too H Alarm management ES Direct X aC IO Manager H Image center A Update DynDNS domain automatically 2 Webserver IF User manager Username Help doubleclick Password VAdministratorWebserver O 2000 2009 logiware gmbh Webserver 76 8 6 Clustermode In the Enterprise edition of 901984 any cameras that have been integrated on a remote computer into another 901984 Standard Pro or Enterprise version can be added as cluster cameras This offers benefits in terms of e Network load images can only be transmitted when a motion is detected the camera on the cluster client is almost in standby mode e Performance it may also be sensible to set up a cluster system for load distribution The cluster server or servers will then
37. gram Calling a telephone number and playing an audio file ISDN card required ss Note All notification types need to be activated first Clicking on the options field of the respective option switches on the corresponding function If the desired option is grayed out there are some settings that must be provided beforehand because the option makes no sense without them For instance the option Telephone call makes no sense if a telephone number has not been provided E E Administrator ES Cameras E IF Cameras ee Wy camera q Je Video A Motion detection H 10 Manager H 2 Image center O Views inf Screens a me Webserver ak age User manager SET Setup 8 Help doubleclick O 2000 2009 logiware gmbh Basic setup 46 6 5 1 Sound 901984 can play a freely selectable audio file in wav format via your sound card in case of a notification Simply choose the corresponding file using the dialog 0 000 E E Administrator Foy Cameras a IP Cameras iy caera E C Program Filesigo1934 Sounds ilotion wav 4 Recording 2 4 Alarm management SEA FTP Upload Ed LAN Broadcast Call EXE Phone call ES Direct 1 3 IO Manager 2 4 Image center 3 Screens fd Bt Webserver oof GY User manager 3 1 fps 13 07 30 PM 2 56 27 PM Axis Camera 207 TAxisCamera Administrator Ca meras lP Cameras My camera Alarm managementiSound To prevent too many notifications fro
38. grams are shut down completely when you close the program window The 901984 Client is only hidden and continues to run in the background While the program is running the 901984 Client symbol is displayed in the task bar near the time You can use it to shut the program down completely or to bring it back to the foreground Clicking on the icon with the right mouse key will open the corresponding menu v Show StatusBar Show Toolbar Stretch fe Setup Show Hide wel Re 236 PM The following functions are also available Show this displays hides the status bar with additional information such as resolution StatusBar notification time image size in the bottom section of the go1984 client window Show Toolbar this displays hides the 901984 client toolbar this expands the image in the visible area stretches 2000 2009 logiware gmbh Basic setup 54 6 5 5 External program go1984 offers you the option of launching an external program in case of a notification In this case the image that triggered the notification can first be saved on the hard drive In this way special tasks can be carried out for which 901984 itself is not suitable To set up the feature select the program you want to launch and the launch type You can choose to have the image that triggered the notification saved on the hard drive first and can freely define the drive and the directory for this purpose El E Administr
39. he whole image so that a motion is indicated For instance in the case of a VGA resolution of 640x480 pixels with a threshold of 1 5 the figure will be 72 segments You should reduce the threshold if you want the motion detection facility to be more sensitive Motion areas are highlighted in the live image with red squares As soon as the actual value exceeds the specified threshold the motion signal is triggered The specified threshold yellow and current actual value green or red are graphically represented by two colored bars in the program to make adjustments easier for you The actual value bar changes from green to red if a motion has been detected The circle in the Motion field also turns red You ll be shown the live image from the camera with motion areas being marked by red rectangles As soon as the actual value surpasses the specified limit value the motion signal is triggered The specified limit value yellow and the current actual value green or red are graphically represented by two colored bars in the program in order to make adjustment easier for you The actual value bar changes from green to red if a motion has been detected The circle in the Motion field also lights up in red Motion where the threshold IS exceeded 2000 2009 logiware gmbh 35 901984 User manual Basic setup It often makes sense to exclude certain areas of the camera image from motion detection In order to d
40. ic setup 16 In both cases the following dialog box appears Add Camera Allnet ALL2297 My camera 192 166 171 111 Username Password You should set the following parameters in it Give the camera a unique nickname which can be used for it in 901984 Enter the camera s IP address or host name here If you have not yet assigned the camera an IP address refer to the camera manufacturer s documentation If a camera port other than the default port 80 is being used you can change this here If authentication is required to access the camera enter your username here Password Enter your password here for the authentication process mentioned above Refer to your camera manual for details of the default passwords Finally click on OK to confirm your details 2000 2009 logiware gmbh 17 901984 User manual Basic setup The camera you ve added will now appear in the branch IP cameras of the 901984 explorer The basic setup of the camera has now been concluded go1984 has automatically activated motion detection and recording for this image source As standard cameras only record when there is a detected motion If you want to record images permanently simply deactivate the motion detection option by clicking on the Motion detection option box el Administrator Fre Caption a Cameras co y E Motion detection eee Recording J Alarm managem
41. ically deleting scenes If more than one criterion is relevant the first criterion to be met will apply in each case the used disk space exceeds in this case you can allocate each camera a disk space quota this value When this option is activated the oldest scenes are automatically deleted when the quota is exceeded the scene is older than when this option is activated the scenes for each camera are automatically deleted when the scene is older than the duration specified in days disk space is less than the oldest scenes are automatically deleted when a quota for the remainder of the disk space is exceeded This value applies across all the cameras which are recording on the same partition hard drive and if changed it is automatically set for all the cameras on this partition hard drive El Administrator Stora e Scene crea creation n PreiPost recording Access periods Log a A Cameras j E IP Cameras EF My camera H Reue een 3 Direct X IO Manager came 2 Image center 2 Webserver AG User manager P Help doubleclick 50 0 MByte 22 6 MByte 200 4 kByte T223 13 PI 12 18 33 P Axis Camera 207 TAx Camera A dministrator Cameras P Camerasikly camera Recording 2000 2009 logiware gmbh Basic setup 30 6 2 3 Scene generation g01984 can aggregate recordings made during a certain interval to so called scenes This makes it much easier to find them late
42. ick on the Services link then on Dynamic DNS and finally on Get Started O 2000 2009 logiware gmbh Webserver 74 All you need to do is complete the Hostname field Choose a hostname that is easy to remember and distinctive If you like you can select a different extension for your domain name using the drop down menu indicated Ignore all the other fields and simply click on the Add Host button If the hostname you ve chosen is no longer available choose a different one DynDNS een Do Services count Suppor News Account meca Add New Hostname Host Services My Services Account Upgrades Note You currently don t have Account Upgrades in your account You cannot use some of our Host Service features Please consider SLA buying Account upgrade that make this form full functional and will add several other features Leam More Premier Support PANE EVER Hostname logitest homedns org Host Services MaiHop Outbound Wikicard Yes alias hostname domain to same settings Recurswe DNS Service Type Host with IF address Network Monitoring WebHop Redirect SSL Certificates O Offline Hostname Renew Services e Auto Renew Settings Sync Expirations IP Address Account Settings ge ee ie 5e auto detected IP address 85 Billing TTL value ts 60 seconds Edit TTL Mail Routing UU Yes let me configure Email routing Search Search 1998 2008 Dyrare Network S
43. ignal as shown in the diagram After you ve defined this setting the camera will start recording as soon as the contact at the camera s digital input is closed kotiondetector Idle Darkness MotionOverload Recording PreRecording Active Scheduler New Image Action Httpevent gt gt gt Error De m er IO m er ss Note Please note that a single input signal can also be linked to several different actions In the example above for instance you could have the same signal trigger e mail notification in addition to recording Furthermore a camera s signals are also available for all other cameras In the example the input signal from a single camera could be used to control the recording function of all cameras 2000 2009 logiware gmbh 95 901984 User manual Appendix 12 Appendix 12 1 POP3 SMTP Server A list of the most common POP3 SMTP servers POP3 Server pop 1und1 com SMTP Server smtp 1und1 com Pop Kontoname ptXXXXXX XXX Mailbox Name POP3 Server pop3 arcor de SMTP Server postman arcor de mail arcor de Pop Kontoname Benutzername ARCOR E PLUS POP3 Server mail imail de SMTP Server mail imail de Pop Kontoname Benutzername FREENET POP3 Server pop3 freenet de SMTP Server mx freenet de Pop Kontoname benutzername freenet de POP3 Server pop gmx net SMTP Server mail gmx net Pop Kontoname Kunden Nummer oder E Mail
44. l has been linked to which action a 3 O Manager a Ewent Aa Camera Fy My camera MA Darkness BA Error 2 Input E Motiondetector vee Recording My camera un Play sound My camera see Email notification My camera un LAN Broadcast My camera toe Call external program My camera 4 Phone call My camera 2 MotionOverload Newimage o 4 FTP upload My camera E PreRecording Y Recording E SceneActive Fy Scheduler A off time Fy Http event O 1 my event O 2000 2009 logiware gmbh Event management 94 gt You can create links anywhere the mouse pointer changes to the following symbol Clicking on the icon with the right mouse key will open the links menu The following example illustrates the process Example An IP camera s digital input has been linked to a doorbell Whenever a visitor rings the bell the camera is supposed to start recording To set up this event first choose a camera in the go1984 explorer and then select the Record option a IP Cameras See My camera H 0 Recording The various settings available for go1984 s recording function are shown The Action button amp is near the bottom The button is linked to go1984 s internal motion detecting after installation You can now change this link mapping it to the camera s digital input Click on the button with the right mouse key to open the menu Afterwards select Input1 as an input s
45. ler a unique name A Enter a name for the scheduler aOOOh Enter a name for the scheduler f Cancel Afterwards define the active and inactive times for each day Simply select the desired times using the mouse keep left mouse button pressed The active part will be shaded in green You can copy any day s settings to a different day using drag amp drop Simply use the mouse to drag the name of the day Monday Tuesday etc to a different day Furthermore you have the possibility of saving the completed scheduler to a file or loading it This is a useful feature when setting up several similar schedulers 2000 2009 logiware gmbh 57 901984 User manual Basic setup El E Administrator El a Cameras IP Cameras gt fee My camera Tuesday Wednesday Thursday Friday Saturday Sunday a Motion detection E A o Recording Sy May 2008 8 29 22 Thu ES 3 __ Alarm management EN a IO Manager El a Event ngi H Camera io 00 dm oo 3 Scheduler off time a 20 Http event ieee Plugin Per un i P o m 5 io Pa 0 ve Action El 53 Image center ia gt Webserver User manager part m7 on per mala mk wo nl ke io oo P Help doubleclick nu z m dm am m x 5 Pe fa at Pa MAdmin istrator IO ManageriEventiSchedulerioff time You can also use the scheduler to turn various camera functions on or off automati
46. m being sent you can set a rest period This means that only when at least the specified time has elapsed since the last playback can the sound file be played again Please also refer to the general notes on activating notification functions in the section on notifications O 2000 2009 logiware gmbh 47 901984 User manual Basic setup 6 5 2 E mail In order to enable e mail sending from 901984 a so called SMTP server see reference first needs to be specified If this has already been done you can continue here directly Select the entry Notification in the go1984 explorer You can now enter one or several recipients separated by semicolons into the field E mail address Adjust the subject line if you wish The variable cameraname is automatically replaced by the name of the camera triggering the alarm when an e mail is sent E Administrator G Cameras a IP Cameras Email addresses Use to seperate Subject Et a Motion detected on Cameraname 4 Recording 51 42 Alarm management RA Attach image to the mail bo EE El Sound SMTP properties 015 FTP Upload DO E LAN Broadcast O BA call Exe Ma ES Phone call ea Direct X AU 10 Manager 403 Image center HS Webserver age User manager amp Help doubleclick 320240 12 3 fps 12 26 20 Pl 12 21 23 PP Axis Camera 207 TAxisCamera Administratori Cameras iP Cameras hly ca mera la rm managementiNotification Onc
47. meras etc Brightness is less than Some cameras tend to produce noisy pictures under bad lighting conditions which can lead to motion detection being triggered This control enables you to turn off motion detection for images generated at less than the specified basic brightness Threshold Automatic go1984 always tries to provide the best settings for the segment threshold independently Threshold Manual analysis of each individual segment without the above mentioned extended adaptively operating settings being taken into consideration for the segment threshold This option is recommended only in exceptional cases 2000 2009 logiware gmbh 39 901984 User manual Basic setup 6 4 Http event Many of the current network cameras or even external network enabled motion detectors nowadays offer integrated motion detection and the facility to notify third party systems of any movement detected via an http message In the Enterprise edition of 901984 the motion detection facility of these devices can be used via the http event This may be a particularly sensible solution on performance grounds where there are a large number of cameras You will find this function under the IO Manager You can add a new event by clicking on the relevant button E E Administrator O Cameras ES lO Manager l a Event 1 03 Camera H Scheduler Enter the name you want to give the event Enter a name for
48. n lt lt Motion detection gt Settings gt Brightness is less than Doro Error the camera reports an error or is not available Idle no further motion has been detected for the value Motion detection gt Settings gt Delayed detection Inputi Input2 the camera s digital input is being closed Motiondetector a movement is detected MotionOverload the motion level is very high see Motion detection gt Settings gt Motion value is greater than NewImage a new image is transmitted from the camera Recording images are being recorded at that moment SceneActive a new scene is recorded and the interval specified without movement which must elapse before the next scene is generated see Scene generation gt No motion was detected for this time interval has not yet expired Scheduler the scheduler is in the green range Http event the http event is currently active 2000 2009 logiware gmbh 93 901984 User manual Event management The different input signals are grouped in the program s IO Manager LEDs are depicted to the left of the signals The LEDs may indicate the following status Signal on Signal off Signal is deactivated and therefore not available default setting for camera inputs and camera outputs You can view the different signals from the cameras in the IO Manager under the Event entry It also shows you which signa
49. n be linked to one or more actions The most important signals are automatically linked to standard actions after 901984 is installed For instance motion detection is linked to recording and notifications of the respective camera However you have the choice of changing these links The following output signals Actions are available depending on camera type O outputi O Output2 E 1a 10 Manager Dutputi This output signal can be used to switch a camera s digital output if available on or off It can be used for applications such as controlling a door opener for instance es Note An IP camera s digital inputs or outputs are not supplied as standard They must be explicitly activated when required in other words set from 0 to 1 E Administrator E a Cameras a a IP Cameras g fe o Recording Duration 6 9 Alarm management Nbrofframes 3 _ Direct X E E 9 IO Kanager ins ae Image center BER gt 5 gt Webserver Color En Ac User manager Baas Ms Setup a Help doubleclick Fps 2000 2009 logiware gmbh Event management 92 The following input signals Events are available Active the camera is active which means that the option box next to the Video option is ticked A Darkness Darkness the brightness of the camera image is very low see Motion detection gt Settings gt Brightness is less tha
50. o so you can draw any kind of mask over the image Various tools are available for doing so The mask is displayed on the screen transparently for control purposes Grayed out areas will be excluded from now on E E Administrator 2 5 Cameras EY P Cameras wy camera eh Video Pr en 7 Recording EJ Alarm management EN Drect X Manager H Image center US Webserver Mey User manager a Setup GP Help deublechek ARA leen ESAS AU 9638 25 AU Axis Camera 207 T xisCamera Admiro nComeras1P Cameras My camera Motion detechen Tools for drawing masks Rectangle tool for drawing masks p ine Wen p ine width 2 Pine mana OOOO CITI i inver mes CIC O 2000 2009 logiware gmbh Basic setup 36 For normal purposes motion detection settings do not need to be adjusted more than described above If the default values don t work perfectly for your needs you ll find additional setup options on the Properties tab E oJ Alarm management EN Directx EJ 10 Managar ECI maga center US Webserver GF User manager G Setup SP Help doubleckek 51 fps 3 10 06 24 A 2 S847 AM Axis Camera 207 TAxisCameral SS SS Se Ee SS AA Y AA AA A VeministratoriCamerasiP Camerasily cameraillaton detecion O 2000 2009 logiware gmbh 37 901984 User manual Basic setup The analyzed segments ar
51. o surveillance and recording This will install go 1984 3 7 on your computer tt is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup GOT YOU 901984 ls watching when you aren t gt Cancel 2000 2009 logiware gmbh Installation 4 If you prefer to install to a different directory or hard drive please select the corresponding option in the following dialog fl Ba errs eee T 5 Se up gol984 je i Select Destination Location Where should go 1984 be installed A Setup will install go 1984 into the following folder To continue click Next f you would like to select a different folder click Browse C Program Files go 1984 At least 0 7 ME of free disk space is required English 2000 2009 logiware gmbh 5 901984 User manual Installation Then select the components to be installed You can choose the 901984 client as well as 901984 see LAN Broadcast section beda Which components should be installed Select the components you want to install clear the components you do not want to install Click Next when you are ready to continue go 1984 go 1984 Client Curent selection requires at least 13 8 MB of disk space English 2000 2009 logiware gmbh Installation 6 The installation routine will automatically create an entry l
52. ordings use There s no simple answer to the question because many factors play a role These include e The number of cameras AK e The number of frames per second FPS e The image size KB e The amount of compression e Whether recording is permanent or motion triggered In order to get a rough idea of memory requirements in the case of permanent recording use the following rule of thumb You can usually assume the image size KB to be about 25 30 kilobytes AK FPS KB kilobytes second This will give you the approximate number of kilobytes needed per second recorded Multiplying by 3600 gives you an idea of the number of kilobytes needed per hour Please note that go1984 uses intelligent ring storage management to contribute significantly to efficient memory management In many cases it makes sense in any case to use motion triggered recording which reduces memory requirements substantially 2000 2009 logiware gmbh 29 901984 User manual Basic setup 6 2 2 Memory management go1984 includes efficient ring storage This enables you to optimize available hard drive space allocation to the cameras thereby ensuring that there is always enough memory space available for new recordings go1984 is able to delete the oldest recordings automatically after the allotted memory has been used up You can also select individual recording directories per camera The following criteria specifically apply for automat
53. ption of pour edition ws Note You must always enter the data for the full version first You can then input the update or upgrade key after this for instance after reinstalling your operating system or moving to a new system 2000 2009 logiware gmbh 13 901984 User manual Basic setup 6 Basic setup In order to use 901984 one or more image sources are required The following sources can be used e IP cameras e Capture cards and TV cards e Webcams USB This section explains how to integrate cameras or other image sources into 901984 It also provides information on how to configure recording on the integrated motion detection feature and on the notification options We ll be working on the basis of a typical case for which the pre defined automatic program settings are sufficient If you wish to make further changes or improvements to 901984 please refer to the section Additional settings 2000 2009 logiware gmbh Basic setup 14 6 1 Adding a camera 6 1 1 IP camera To add an IP camera select the entry IP cameras in the 901984 explorer zg E Administrator Ger fo ha r Direct X g 4 03 IO Manager n Image center ae er Webserver 1G User manager 2i EJ Setup bee Y Help doubleclick You now have two options for adding a new camera 1 Camera picture A list is displayed showing you pictures of all the available cameras arranged in alphabeti
54. r The concept used is quite simple Any scene that has already begun will be continued if less time than defined in the field Time interval has passed If more time has passed a new scene is generated You can also define that a new scene should be generated as soon as the scene file becomes larger than the value entered into the field File size or if the current scene is longer than the value entered into the field Duration The following criteria specifically apply for generating scenes Once again if more than one criterion is relevant the first criterion to be met is decisive no motion was detected for if the time between two recordings triggered by motion detection this time interval is less than specified here the scene already begun is continued But if this time is exceeded a new scene is generated The same applies if the recording is triggered by a signal other than internal motion detection e g by a camera s digital input signal or by an http event the size of the scene file is a new scene is generated if the current scene exceeds the size greater than specified here the duration of the scene is if the scene duration specified here is exceeded a new scene is longer than generated If scenes are recorded by default only when there is a detected motion the scene generated in this case will usually cover a longer period than specified under this point 2000 2009 logiware gmbh 31 901984 User manual B
55. r manager Ag Setup ay amp Help doubleclick Username GEBE Password City Number of licenses 2000 2009 logiware gmbh 11 901984 User manual Entering the license code Please take care to transfer the data exactly as you received them by e mail or on the license card You will sometimes find a numerical input for the name or place in the activation data If this is the case enter the specified numerical sequence qo1 984 needs to be registered to use it beyond the 30 day tral period Click on the link below for secure registration http iw gol dee de After registration the registration code will be emailed to the email address provided by you Enter the registration data received by you to complete the registration Mame o City Registration code If activation fails please check whether you entered the data correctly In 99 9 of all cases typing or transcription errors are the reason for activation failing 2000 2009 logiware gmbh Entering the license code 12 If you have purchased a license extension or an update to a higher edition click on Input upgrade key to enter the new activation data The installed license code allows you to download and install new releases of gol 964 in the same edition until 4 25 2008 Tou must enter an upgrade code if you want to use a higher edition or if you want to renew the subscri
56. r or you can add more vi The definitions describe the following in detail Size size of the whole view numbering of the objects contained these may be specifically PaintBox a placeholder for the camera image PTZ a placeholder for the PTZ field for a controllable camera Size Width 800 Height 600 1 Object PT Left 16 Top 12 Width 189 Height 196 2 Object PaintBox Left 352 Top 12 Width 320 Height 240 ss Note The new template will only be available after you have restarted go1984 2000 2009 logiware gmbh 83 901984 User manual Additional settings 10 Additional settings 10 1 Camera In order to modify other camera settings please select the camera in the 901984 explorer You now have the option of influencing image processing mel Note regarding IP cameras The EE button carries out a special function While it is activated the original jpg image from the IP cameras is used in go1984 modifications such as rotating mirroring or adding text are not possible In this way go1984 can run at its optimum performance level Wherever possible try to apply camera settings in the camera itself which make further modifications by go1984 unnecessary If your camera is not able to do this deactivate the TFE button and apply the settings in 901984 H E Administrator 4 3 Cameras 2 a E IP Cameras SE gt My camera ran u o en n a My camera 23 05 2008 09 09 10 1
57. s you can integrate it into go1984 For this you first need to activate DirectX support To do so select the option as indicated in the diagram At the next program launch go1984 will search your computer for available DirectX devices and display them under DirectX in the go1984 explorer E E Administrator E a Cameras a 3 IP Cameras My camera e e Motion detection E Id e Recording El E Administrator Ba Cameras E IP Cameras E a My camera e gt Motion detection a Er o Recording E q o Recording Bog Alarm management A IO Manager El 42 Image center oe gt Webserver ge User manager eK Help doubleclick Taa Ts al Load DirectX on startup Microsoft LifeCam WX 1000 01 56 65 40 dropped frames 140355 IM icrosoft LifeCam 451000 O 2000 2009 logiware gmbh Basic setup 24 6 1 4 Capture card Capture cards are physically installed into the PC and convert analog image signals into digital signals Start by installing the card in your computer and installing all required drivers as indicated by the card manufacturer s instructions Most single channel capture cards based on the BT878 chip can be used Usually only the first channel of multichannel cards can be used in 901984 In addition 901984 supports the following four channel cards e Spectra8 by ITuner e Videum4400 by Winnov After you ve installed your capture card successfully it will be
58. s requesting you to enter a name for the new language e g Spanish Use the existing languages to translate terms line by line into the new language After completing the translation the newly created language option is immediately available Startup Http proxy T sum properties Scenecache Translation Error Log State Confir Confir cameras Development enviroment English Copy to clipboard Delete FGO1984_MSG DIRECTX FGO1984_MSG_IMAGECENTER Confin FGO1984_ MSG IOMMANAGER Confirmed FGO1984 MSG _IPCAMS Confirme FGO1984 MSC LICENSENOTW Confirmed FGO1984_MSG_MSG TOOLTIP Confirmed FG01984_MSG_PLEASEMAIL Confirmed FGO1984_MSG PLUGIN Confi Equalize same conceptions Remove language German Export language to text file spanish Import language from text file Czech Export as CSV Russian French EEEEELEEE EE talian Confirmed Portuguese FGO1984_MSG_SETUP Polish zur Turkish Simplified Chinese FRBASEWIDEO_MSG_NEWEAMNAME Traditional Chinese Swedish 2000 2009 logiware gmbh 91 901984 User manual Event management 11 Event management go1984 includes a highly flexible event management option which permits 901984 to be individually configured Various input and output signals are available These signals can be supplied to 901984 by cameras schedulers or plug ins Every input signal ca
59. s to the different browser views we activex A default uE iPhone java A E jawascript us pda Cheensa ver E Tree BPE wap Don t forget to save the edited settings using the Save button e Note If new cameras are integrated after a user is created the right to access the cameras must be granted explicitly to the user that has been previously created 2000 2009 logiware gmbh Webserver 62 8 Webserver 901984 provides an integrated webserver that is accessible from local networks and the Internet using TCP IP The server makes it possible to access the live feed and recordings using the Internet Explorer Controlling PTZ cameras is also possible What s makes the feature special are the HTML templates which permit a completely customizable design of appearances and functions Use the examples provided to adapt them to your own needs You ll find the templates in the following directory lt InstallDir gt Web where lt InstallDir gt is the directory where go1984 was installed Praia a 2 Qu a a a Gy ul gen e 0 A O 2000 2009 logiware gmbh 63 901984 User manual Webserver 8 1 Configuration 901984 is delivered with predefined webs that can be called up using an Internet browser Every web is saved in its own subdirectory The root web directory can be specified In addition the available bandwidth can be limited 901984 analyzes your computer s network
60. sername and so on Properties Domainname Sessions Sequence of cameras Log Max bandwidth ekda 00 03 27 5 26 2008 1 28 39 PM Administrator 89 7 kByte 5 26 2008 1 25 39 PM 192 168 1 50 4 9 MByte s 2000 2009 logiware gmbh 65 901984 User manual Webserver 8 2 Interface Call up the web interface in your browser by using the following URL http ip port Replace the variables as follows by the IP address or domain name of the computer running 901984 by the port defined in the webserver configuration default is 80 You will then end up at the web server homepage where you can choose the web and transmission quality that you want high or low You will also find the option to install the 901984 desktop client logiware zum uns You can also access the web you want directly http ip port web Replace the variables as follows ip by the IP address or domain name of the computer running go1984 port by the port defined in the webserver configuration default is 80 by the directory name of the web The following webs are predefined as examples java tree activex javascript pda iPhone 2000 2009 logiware gmbh Webserver 66 In the tree web you can also specify the camera or view you want directly view x 1 2x2 2 3x3 etc or camera cameraname The complete URL could look something like this The
61. t automaicaly when windows starts f Select a skin 87 901984 User manual Additional settings 10 3 HTTP Proxy If a proxy server is required for the HTTP protocol in your network define the necessary settings here Ask your network administrator for the correct settings E E Administrator Seen Cameras 7 EE IP Cameras _ Use Proxyserver EIN My camera Server Y E Motion detection ff Recording 3 1 03 Alarm management ES Direct X H lO Manager a Image center gt Help doubleclick 2000 2009 logiware gmbh Additional settings 88 10 4 SMTP server configuration In order to enable e mail sending from go1984 a so called SMTP server first needs to be entered this only has to be done once Outgoing e mails are sent to this server and ultimately to the recipient Your provider can supply you with the settings required to configure the SMTP server Alternatively you can obtain the information from your e mail program Outlook Outlook Express etc A list of the most common servers is supplied in the appendix El EE Administrator Ey Cameras a IF Cameras Email addresses Use to seperate E My camera Loo neW Vi Subject Er Motion detected on Cameraname Recording ie Alarm management Y Attach image to the mail 3 LAN Broadcast Call EXE Phone call ae Direct aL IO Manager Setup Help doubleclick i 320240 12 3 fps B u mn o 12 26 20
62. take over motion detection while the cameras on a central cluster client are brought together A new cluster camera is created on the cluster client in the same way as adding an IP camera This means that you select the IP cameras option in 901984 Explorer Then choose the camera go1984 Camera from the selection list Wisicom e Vivotek a Now specify the IP address or host name under which the go1984 cluster server can be accessed Address of camera O O Enter IF address or hostname 62 75 214 164 He f Cancel Enter a nickname Cluster camera 2000 2009 logiware gmbh 77 901984 User manual Webserver Login Cluster camera Username Password Be Remember username and password E Administrator EG Cameras E IP Cameras EM Cluster Motion detection fg Recording A J Alarm management fi Direct X a lO Manager H Image center la Webserver acy User manager Help doubleclick Admin istratoriCamerasWP_ CamerasiCluster cameralWideo 6060 If the user manager is active on the cluster server you must enter a valid username password combination for authentication You must then enter the name of the cluster server camera in the Camera field which you intend to access You can also determine via the Motion parameter whether images should be transmitted permanently Motion 0 or only when motion is detected Motion 1
63. the camera model 1 Via the arrow keys Slide pan and tilt 2 Via the slider Tiltelider 3 Via click and drag Click on the button in the centre and hold the mouse button down Now move the mouse crosshair within the PTZ field to move the camera to the position you want which also allows you to use the pan and tilt functions comfortably Slide pan and tilt O 2000 2009 logiware gmbh Basic setup 20 4 Via Ctrl mouse click in the live image If the live image is visible and the camera name highlighted you can also control the camera using the Ctrl key and clicking inside the live image In order to control the camera zoom go across the image with the mouse and move the mouse scroll wheel These functions are also supported in an image center display El E Administrator EE a Cameras E P Cameras lg e Motion detection of LH a Recording E 43 Alarm management El 35 I0 FEREN E 423 Image center fA Webserver HE User manager P Help doubleclick Ctrl Click Original in image fror ige from source device i is used Use labelling rotating and quality from the Sourc eel nae Ten A a Man ran rar rm nn en mn Ms 5 ps i T 56 4 49 A NE ij 56 03 Al Sony SNC RZ25P SP TSonyCamera ees z gt 2 Administrator Cameras IP Cameras PTZ camera un nd sn mn in 5 Via Area zoom If the
64. tup Then you must link the recording in the http event E E Administrator E a Cameras El IP Cameras EMB My camera iiH Ar Video u 00 Sen a lO Manager a Event E Ele Camera E Scheduler E a Http event H E Action E m Image center td D Webserver oy User manager ie a Help doubleclick Alarm management Storage Scene creation Disconnect Pre Post recording Access periods Scheduler go1984 which is linked by default to go1984 motion detection to If you are not going to continue using the go1984 motion detection function any more or as an alarm function for instance you can now deactivate it El E Administrator 3 2 3 Cameras 5 P Cameras EA My camera BR F video 2000 2009 logiware gmbh Basic setup 44 nis Note Sometimes you need to still change the values for the pre and post alarm so that the recorded scenes cover the overall period you want O 2000 2009 logiware gmbh 45 901984 User manual Basic setup 6 5 Notification g01984 can use various channels to notify you in case of an alarm They are Playing an audio file via a sound card Sending an e mail with or without an image attached Uploading one or several images via FTP Sending an image to the 901984 client via UDP Broadcast Launching an external pro
65. ut a password at first However you should define a password as soon as possible by editing the Administrator account Username Administrator Password blank Be E Administrator E a Cameras P Cameras Direct X ce lO Manager Administrator BBL Access rights El Ab Image center H A Cameras LIL General __ Treeview __ Web Delete user Administratonilser manager 2000 2009 logiware gmbh 61 901984 User manual User management The User column displays all existing users Use the three buttons to create edit or delete users Please note that a newly created user has no rights by default In order to edit a user s right first select the user Afterwards use the Access rights column to allow or deny the desired options You can also change several users rights in a single step To do so first select the first user then press the CTRL key on your keyboard and hold it while selecting one or several users from the list Access rights are subdivided into the following areas i Cameras Access to live feed PTZ control recording period E __ My camera wo PTZ camera fa we Long period me Medium period ae Short period me Unlimited w General Deletion of scenes r e DeleteScene Treeview sia Treeview Access to IO functions webserver settings camera settings we Directx 2 Imagecenter we OManager TS IPCams amp Setup amp WebServer ar Web Acces
66. veillance and recording Setup has finished installing go 1984 on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup View Readme bd Execute go 1984 GOT YOU 201984 ls watching when you aren t Finish In the Enterprise edition go1984 can be installed as a service To do this you start the program on a one off basis via the command line using the parameter install ES Administrator CA Windowe Syste m32 cmd exe Ioj x A message will appear indicating that the service has been successfully installed 901984 Ea gcl984 service successfully installed 2000 2009 logiware gmbh Launching the program 4 Launching the program After installing 901984 there are various ways to launch it 1 Launch using the Windows quick start bar A5 Video surveillance a Computer aNErWOrE 3 Launch using the start menu Select Start gt All Programs gt 901984 gt 901984 Default Programs Ly 901984 e Help gt Uninstall g Help and Support gs Video sur Video surveillance a 2000 2009 logiware gmbh 9 901984 User manual Launching the program 4 Autostart If you want 901984 to be launched automatically when your computer is switched on please activate the option shown in the following diagram If you are going to run
67. wsiMy view 2000 2009 logiware gmbh 81 901984 User manual Image Center You can define as many views as you like which can then be displayed simultaneously on various monitors or sequentially on a single monitor Next select the Screens entry from the 901984 explorer in order to generate such a representation First click on the Create a new screen button A Screen can contain one or more views Use the button to select and add the desired views to the list of Views for this screen If you ve added several views 901984 can automatically switch between them at certain intervals Et Administrator Ela Cameras ie Show Y Hide Ay IP Cameras os My camera Linked views Position Shortcut Properties Direct X ao I0 Manager Ey Image center o 872 My view E Switch views automaticaly Admin istratorimage center Screens My screen You can modify additional settings such as Position Keyboard shortcuts or Properties using the corresponding entries Clicking on the Show button displays the preset Screen 2000 2009 logiware gmbh Image Center 82 Defining customized views If the views supplied don t match up with your expectations you can add more templates in a simple manner You will find the definitions for the views ini under the 901984 installation folder in the Template directory You can edit these using a simple text edito
68. y camera H 16 25 10 268 eof 14 56 21 823 se 14 50 35 880 s 09 13 52 109 ff 09 12 35 843 oF 4 53 Alarm management EN Direct X E 1 63 IO Manager El 4 23 Image center Br gt Webserver User manager r Help doubleclick In addition you have the option of changing the playback speed of the preview mode and of defining the width of the preview scenes 2000 2009 logiware gmbh 27 901984 User manual Basic setup Scene playback You have two different modes available when you come to play back individual scenes kai Loop mode the scene that is currently selected will be re run at the end of the scene m Endless mode fall the scenes recorded on the camera are played back in sequence in chronological order T Comes EL TE a E IP Cameras Play Sp ie My camera ATmr O05x Mix B2x Dax a a Motion detection E ze Recording EY May 2008 H 23 Fri Eo 22 Thu Y 16 27 25 705 16 25 10 268 14 stk 21 ai B 09 13 52 A mE 09 12 35 843 a al Alarm management H T IO Manager E H E Image center Zr gt Webserver ae User manager y Help doubleclick a 32272008 2 50 38 PM 719 Admin istratoriCamerasWP CamerasiMy ca mera Recordin g May 200822 Thui14 50 35 880 2000 2009 logiware gmbh Basic setup 28 6 2 1 Calculating memory requirements One of the most frequently asked questions is how much hard drive space will the rec