Home

Ultratrend DMS 5.0 Data Management System

image

Contents

1. Load Saved Query WHERE Plant Name MAPLE STREET ORDER BY Location Number Point Num Save Custom Query 25 i lt Back Next gt Cancel Help amp Contact Information For assistance with Ultratrend DMS contact UE Systems between the hours of 9 00 AM and 5 00 PM Eastern Standard Time Telephone 914 592 1220 Fax 914 347 2181 Email info uesystems com 26
2. Click on Remove iii Attach To This must be performed after an image has been Added to the Image file If an image is attached to an historical record than you can select any of the categories above it when Attach To is selected Set IN oe There are two methods for attaching an image The first is to use the Historical Record To attach an image using the Historical Record 1 Select the Historical Record 2 Open the Image tab 3 Select Attach To and then click on one of the categories Baseline Point Location Machine or Group The second is to use any other category Baseline Point Location Machine or Group 1 Select the category to which you will attach the image 2 Click on Attach To 3 Click on the category 11 c History The History Chart is a spread sheet to display selected information for a specific Test Point The information will also be used to create a trend chart To create the spread sheet in the History tab Select the desired Test Point Open the History tab if it has not already been opened Use the Selector box located on the extreme right of the History tab Highlight the desired test information item Use the left arrow key to move it to the spread sheet 6 Use the right arrow to remove any column from the spread sheet d Chart The Chart tab displays the information you selected in the History tab as a Trend Chart The Y Axis displays the dB while the X Axis shows the date The Y Axis scale can be
3. right click on the descriptor and select Rename To create a new Location Machine Highlight the Group and then Select Edit New Location Machine or right click on Group and select New Machine Location E RECORD POINT The Record Point is the specific test point that will contain all the Historical Records that are listed by date of entry The Record Point may be set using 8 or 3 characters depending upon the selected Location Machine format The Record Point will be listed sequentially in order of a specific test route Therefore the first Record Point will automatically be assigned 001 the next 002 up to 400 to cover up to 400 records When data is entered into the Record Point an Historical Record will be created After it is created either by downloading data from the Ultraprobe 15 000 10 000 9000 3000 or manually entered the Historical Record will be listed under each Record Point as a date To create a new Record Point 1 Highlight a Location Machine 2 Select Edit New Record Point or Right Click on a Location Machine Select New then Record Point F HISTORICAL RECORD An Historical Record contains data Fields associated with a specific Application Each time an inspection is performed the new data will be stored in the Historical Record Fields associated with the time and date in which the inspection data was collected The first entry is defaulted by the program as the Baseline record This may be
4. adjusted by selecting the high and or low values and re entering a new value If the chart line values are too high up the scale and difficult to read select the highest value shown at the top of the chart then re type a higher value For example if the highest value were 50 highlight the 50 and re enter a higher value such as 60 The chart will move down For low values perform the same select the lowest value and enter a new lower value lee So When viewing a Chart there is an option to print the Chart or to save the chart If the Chart is saved it can be attached to a Point that will be inserted into a report It can also be attached to a Baseline record for sending to an Ultraprobe 15 000 and viewed while inspecting a Route e Alarms Alarm levels can be set for high and low alarms A new baseline level can also be set To use an Alarm tab the Historical Record must be selected It is recommended that the Baseline Historical Level be opened when creating the alarms If a new baseline is to be used select the appropriate baseline Historical Record and continue When the Alarm tab is opened there are two choices Update All Alarm Levels using values or Update All Alarm Levels using deltas 1 Update All Alarm Levels using values a This defaults to a Low Alarm of 8 dB and a High Alarm of 16 dB over the first reading The first reading is automatically assumed to be the Baseline reading 2 Update All Alarm Lev
5. changed by clicking on the Baseline Icon located in any Historical Record It is the Baseline record that is uploaded to an Ultraprobe The Baseline information is used to be compared with the test data as it is being collected and it is the record used to set Alarm levels With the Ultraprobe 15 000 if sound files and or images have been attached to the Baseline record all will be sent for viewing on board while performing inspections out in the field The Historical Record contains data Fields that are downloaded from the Ultraprobe and uploaded to the appropriate Ultraprobe You may create an unlimited number of Historical Records for each Record Point An Historical Record contains all the inspection data unique to a selected APPLICATION To view an Historical Record it must be selected in the tree on the left of the data screen The data can be automatically entered into the Historical Record by downloading the information from the Ultraprobe If images have been attached or if sound WAV files have been connected to a particular Historical record an icon will be attached 1 Image Attached Icon JE DRIVEA 001 When an Image has been attached to an Historical Record an Icon will appear to the left of the Test Point in the Hierarchy tree 2 Wave File Connected Icon 3 20 2008 When a Wave File has been attached to an Historical Record an icon will be displayed to the left of that record IV TABS The tabs on the up
6. dB indicators move Fast Medium Slow Units Standard or Metric Scale Relative or Offset refer to Ultraprobe user s manual for details Instrument enter the Ultraprobe used for this test Serial Number enter the serial number of the instrument used for this test Test Results this data varies depending on the application Move a Record After an Application is set and the data is entered into a Record Point there may be occasions when the sequential order must be changed A Record Point may be out of sequence or in the wrong position To change the order click on the Record Point you wish to move Drag it to the new location Adialog box will open and ask Move the selected record and insert after the drop location If this is correct select OK If it is not what you wish to do select Cancel Once selected all the values located below the point of the drop location will be automatically updated in sequential order akWN Delete a Record To delete a record 1 Select the record you wish to delete 2 Right click the mouse and select Delete Adding a Record To add a record Right click on the desired LOCATION MACHINE Select Create Record Point b Images An Image can be attached to a Group Location Machine test Point Historical Record or Baseline An Image or sound file that has been saved to a test Point while using the Ultraprobe 15 000 will automatically be attached to t
7. effectively you must have set alarm levels in DMS 2 Up Images This report will put two individual records per page with one image per record It will choose the very first image in the record i The Path file window will open select the path and name the report ii Click OK iii Review your report Compressed Gas This report displays data for your leak survey It can be used for any gas The default gas selections in the sheet are Compressed Air Argon Helium Hydrogen and Nitrogen It will compute the cost of the leak and the impact on your plants Carbon Footprint You may adjust your local carbon gas emissions in the coefficient located on the bottom of the Compressed Gas report sheet There are tabs on the bottom of the spread sheet which will guide you to Cost Report annualized updated report Month Monthly results Master this blank sheet is only used to facilitate importing of data and does not need to be used Flow Rate Chart for setting your CFM Guesstimate and a Coefficient Table to select your greenhouse gas results by the state area in which you perform the test It will report the savings per month and globally update the Report Sheet to review your results on an annualized basis 22 d Everything This report will include all the data entered in DMS for each test point There are two formats to select Excel or Text Spreadsheet csv Once saved the spreadsheet can be edited 4 To Generate one of the
8. Microsoft Excel option be sure that you have this program already installed in your computer Select Next To save this report you will need to select a location in the Save As box Check to see if the file name is correct change if not check the Save In box to be sure the report is going to be saved in the correct location To save select the Save As button If you do not want to continue select Cancel The next dialog box is Export Completed If you do not wish to save this query select Finish To save this query for future use Select the Save this Query button When this is selected the Save As box opens Select the folder and location in which you will save your data When you have selected the file location for the Query the Export Completed dialog box will open again select Finish B Creating an SQL Report Using the Create SQL Report opens an Advanced Filtering window Here you can Load a Saved Query or Save a Custom Query that you will use for future reports If you select Load a Saved Query it will open the DMS SQL file If you select Save a Custom Query remember to provide it with a file name Export Wizard Advanced Filtering Enter a custom SQL query or load a pre saved query from file Please enter your custom SQL string in the box below or press Load Saved Quer ta Inad a nre caved miary fram a file Custom SQL Query SELECT FROM All Info
9. Test Point and drag it to the desired location Release the button at the desired location You will be asked Are you sure you want to move the selected Location if you do click on Yes and the move will be completed Vil VIEWING WAV SOUND FILES IN UE SPECTRALYZER If a sound file has been attached to a record Historical Record in the Ultraprobe 10 000 or the Ultraprobe 15 000 the file link will appear in the WAV File window on the Record Information tab when an Historical Record has been opened To view the sound in UE Spectralyzer look in the WAV File box on the Record Information tab and click on Open Wait for UE Spectralyzer to open and click on Run in the Spectralyzer window To enter a sound WAV file manually after an historical record has been created 1 Use either an SD or Compact Flash card or memory stick to transfer the sound to a file folder 2 Insert the memory card CF Card into the card reader or into the memory port of your computer Open My Computer Locate the temporary drive for the memory card Select the WAV file Open Edit and select Copy or use Ctrl C Open Program Files Open the Ultratrend DMS root directory select DMS Plants 9 Open the Plant Folder being used 10 Open Edit and select Paste or use Ctrl V 11 Paste the WAV file into the WAV folder in the plant you are using 12 Open the Historical Record and in the Record Information tab 13 look for the WAV File box 14 use the F
10. a uploaded to the Ultraprobe The process will then require renaming the Location Machine and Test Points after the data has been downloaded to DMS If new select Edit then New and then Plant Provide a name for the Plant Select the Application Label name the Group Perform the test in the field Download to DMS If needed any of the original items can be re named If the test points or Location Machine are not in the desired sequence perform a Drag and Drop operation to move the item to the desired sequential location See section VI Drag and Drop Raw In this instance no Route has been created the test is performed in the field and the data is to be downloaded to DMS after the test is completed Perform the test in the field Open DMS create either Plant Application Group Select Group by clicking on it it will be highlighted in Green Open Communication and download the route Rename Location Machine and Point 18 f If the test points or Location Machine are not in the desired sequence perform a Drag and Drop operation to move the item to the desired sequential location See section VI Drag and Drop Vil DRAG amp DROP This is a typical Windows function When you have finished planning a Route or have returned from a Route and discover the sequence of your Route needs to be changed use the Drag amp Drop feature Left click and hold the mouse button over the out of sequence Location Machine or
11. above reports i Select the report template you will use ii Click on the Generate Selected Report box iii Choose the path to the file window opens name the file and select the path iv A window will announce the report was successfully created Locate the file and review the results Just the data for test points in the alarm state Low or High will be displayed 5 Steam 1 Select the Group you will use for the report 2 The Steam icon will be highlighted and a dropdown menu will appear 3 Your choices for the report include a Alarm Report This will produce test points that are in an alarm state It will be created in MS Excel To use this report effectively you must have set alarm levels in DMS b Steam Report This report details the steam trap survey results and the steam trap condition When you select this template a Select Report Conditions window will open Select the conditions you want to use in your report You can select All Conditions NE Not Entered OK LEK Leak BLW Blow through NIS Not In Service PLG Plugged SIZ Sizing issue OTH Other When you have made your selections click OK The test report will include columns for Point Area Point Manufacturer Application Type Operation Type Pipe Size Orifice Size Inlet Temperature Outlet Temperature if used A B C D Test Results c Everything This report will include all the data entered in DMS for each test point There are t
12. ant this selection will provide you with a list of the Plants you have created Select the Plant to be copied and then edit or reformat to create a new but similar Plant Route iv Close Plant Select a Plant in the tree that you want to close then select Edit Close Plant and that Plant will be removed from the tree v Configure Lists These are lists that contain information related to describing details of a test for an Application They can be uploaded to the Ultraprobe 10 000 and 15 000 to be used when entering test data in the field and can also be used as short hand descriptions when entered into an Historical Record when a route has been downloaded to DMS The list descriptions are preset in the software but can be changed or Configured To change a list 1 Select Edit Configure Lists 2 Choose an Application 3 On the lower left of the Edit Lists box is List Name This is the name of a specific test item that is appropriate for the selected i Edit Lists oe E wee Application Electrical z fme 4 Select the List Name you want to edit for example Test List Name COR Results ee 5 The List Item Box on the Right side of the Edit Lists box will tem Component Voltage i display the item as 3 letters such as NE for Not Entered or 13 Revert to Default Cancel LUB for Lubricate or if Electric was selected COR for Corona 6 Highlight the List Item and change using up to 3 capitalized
13. d to and downloaded from the Ultraprobe Each Application has its own unique record structure A Plant can contain only 6 Applications These are Generic Valves Bearings Electrical Steam Leaks oS oN gt An Application can contain an unlimited number of Groups Groups can be a general area that includes the subject test equipment An Application can be selected when the Create Plant window is opened After a Plant has been created new Applications may be assigned as follows 1 Either click on Edit select New and Select Application or Right click on the opened Plant 2 Select New then select Application 3 Use the down arrow in the Application Type box to view the applications Select the Application 4 Enter a Group name select a descriptor format 13 3 or 8 8 The descriptor will be used to describe or label the item Location Machine you will be testing and the Test Point 5 When finished select the Create button 6 If a Group was previously created in Excel it can be imported here C GROUP e The Group is your Route It is the specific test or project area that includes the equipment to be tested e The Group is what defines the records that are sent to the Ultraprobe e Only one Group at a time can be sent to an Ultraprobe and the entire Group will be sent e f your work plan requires using more than one Route at a time and you are using an Ultraprobe 10 000 or 15 000 consider using multiple Compact Fla
14. eadsheet and contains the Test Point data for your Group The columns include Point Name Location Machine Alarm Lubricated and Comments To Generate one of the above reports 1 2 3 4 Select the report template you will use Click on the Generate Selected Report box Choose the path to the file window opens name the file and select the path A window will announce the report was successfully created Locate the file and review the results Just the data for test points in the alarm state Low or High will be displayed 20 2 Bearing 1 Select the Group you will use for the report 2 The Bearing icon will be highlighted and a dropdown menu will appear 3 Your choices for the report include a 4 Up Images In this report you can attach up to 4 images for a test point i When selected a window will open select the point you will use in the report and the images that were attached up to 4 will be included in the report ii Select the image or images iii In the pull down arrow you may select the image and the position in which you would like the image to set in the report as image 1 2 3 or 4 You may also select not to use the image iv Click OK v The Path file window will open select the path and name the report vi Click OK vii Review your report b Alarm Report This will produce test points that are in an alarm state It will be created in MS Excel To use this report effectively you must have set a
15. els using deltas a This can be used to determine the low and high alarm levels over a set Baseline reading Here you may select any dB value over the baseline For example should you find that an appropriate low alarm level for a test subject is 10 dB over the Baseline reading set the 10 in the Low Alarm Delta box Then determine what the High Alarm value should be and enter that in the High Alarm Delta box 12 The record information of the specific Historical Record you have selected when opening the Alarm tab will be displayed in the box at the bottom labeled Record Information f Reports A report may be generated for any Group within an Application To generate a report 1 Select an Application 2 Select a Group 3 Within each Group there is a dialog box with report templates that are Application Specific You can select from any of these templates or you can create your own Custom Report 4 Ifa report format has been saved it may be opened in the Create SQL dialog box V GETTING STARTED Understanding the Features A FILE Under File there are the following Features Actions i Open Plant Here you can open a previously created Plant which will contain all the basic route information and data ii New Plant This is used to create a new plant and will open the New Plant Wizard to help guide you into creating your route details ili Save a Copy of Plant If you want to reproduce a previously created Pl
16. hat historical record when downloaded to DMS For Ultraprobe 15 000 users when an image is assigned to a baseline it will be uploaded to the Ultraprobe 15 000 along with other baseline information 10 For any of the digital Ultraprobe models once an image has been assigned to an Historical Record it may be attached to any category in the tree above it Baseline Point Location Machine or Group Multiple images may be attached to any of the above categories When generating a report you may include up to 4 images for the test point included in the report When an image is assigned to a Point it can be included in a Report There are three main functions in the Image tab Add Remove Attach To i Adding an Image If an image is to be entered and linked to a Group Location Machine test Point or Historical Record manually perform the following 1 Highlight select the category e g Point 2 Select the Images tab if it has not been previously selected 3 Locate the Add button on the bottom left of the Images tab box 4 Click on the Add button 5 Using the Windows box locate the file and then select OK ii Deleting Removing an Image To delete an image Highlight select the Location Machine Test Point or Historical Record Select the Images tab if it has not been previously selected Be sure the image you want to delete is highlighted Locate the Remove button on the bottom left of the Images tab box
17. ile icon 15 locate the path to the sound file 16 click on the file select Open or double click on the file The sound path will be registered in the WAV File box ONO amp 19 Vill CREATING REPORTS There are three procedures for creating a report using Icons for Specific Applications Creating a Custom Report and Creating a SQL Report To use any of these refer to the instructions below A Creating a Report using Icons Templates There are 6 Icons representing the Applications in DMS Generic Bearing Electric Leak Steam and Valve 1 Generic a Select the Group you will use for the report b The Generic icon will be highlighted and a dropdown menu will appea c Your choices for the report include Alarm Report This will produce test points that are in an alarm state It will be created in MS Excel To use this report effectively you must have set alarm levels in DMS 2 Up Images This report will put two individual records per page with one image per record It will choose the very first image in the record 1 The Path file window will open select the path and name the report 2 Click OK 3 Review your report d Everything This report will include all the data entered in DMS for each test point There are two formats to select Excel or Text Spreadsheet csv Once saved the spreadsheet can be edited e Master Route This spreadsheet is useful for mechanical routes This is saved as an MS Excel spr
18. larm levels in DMS c Lube Route This will generate a report for those bearings in an alarm state The columns in this report are Machine Point Date Frequency dB Sensitivity Low Alarm High Alarm Alarm Status Type of Lube and Lubed d Everything This report will include all the data entered in DMS for each test point There are two formats to select Excel or Text Spreadsheet csv Once saved the spreadsheet can be edited e Master Route This spreadsheet is useful for mechanical routes This is saved as an MS Excel spreadsheet and contains the Test Point data for your Group The columns include Point Name Location Machine Alarm Lubricated and Comments 4 To Generate one of the above reports i Select the report template you will use ii Click on the Generate Selected Report box iii Choose the path to the file window opens name the file and select the path iv A window will announce the report was successfully created Locate the file and review the results Just the data for test points in the alarm state Low or High will be displayed 3 Electric 1 Select the Group you will use for the report 2 The Electric icon will be highlighted and a dropdown menu will appear 3 Your choices for the report include a 4 Up Images In this report you can attach up to 4 images for a test point v When selected a window will open select the point you will use in the report and the images that were attached up
19. le s below and choose whether Export all data DO NOT filte Export data that matches AN Use the ANY to use more ee eee Use the ALL to use more Field Condition Type Condition inclusive rules restrictive rules e g Date xi is equal to i 8 20 2010 lt Back Cancel 24 10 11 c Export Data that matches All rule This will be a limited report to a narrow scope of information Here you will have to define exact parameters such as a specific date range Alarm Status and specific Group It is more restrictive For example Only A and B 6 The Preview box will open If you wish to change anything use the Back button If you approve of the items shown select the Next button S Export Wizard 7 gt Preview The exported data file will contain the information displayed in this pr Please check the table below to ensure that it contains the data you wich ta he eynarted Group Point Point Date dB Freque High Z Low A Machi 1 DRIVE 3 20 2 32 30 48 40 Machi 1 DRIVE 4 20 2 37 30 48 40 Machit 1 DRIVE 5 20 2 41 30 48 40 Machi 1 DRIVE 6 20 2 34 30 48 40 Machi 1 DRIVE 7 20 2 50 30 48 40 Machi 2 DRIVE 3 20 2 31 30 47 39 Machi 2 DRIVE 4 20 2 34 30 47 39 Machin gt Monet EANAN AN on a7 20 g lt Back Next gt Cancel The Select Output File Type dialog box has 2 options Microsoft Excel 2003 2007 Workbook and the Comma Separated Text File csv If you select the
20. letters 7 If you want to return to the original List as it came from the factory the default values click on the Revert to Default box 8 Click OK when through vi Data Base Manager This feature is used to re format your route data If the original setup needs to be changed you may do so here When selected the dialog box offers the following changes Split a Group Merge Two Groups Move a Group Split a Plant Merge Two Plants Repair Group The Repair Group function helps repair corrupted or unrecognized data in a Group B EDIT Under Edit are the following Features Actions i Cut aLocation Machine Test Point or Historical Record ii Copy Copy a Location Machine Test Point or Historical Record iii Paste Paste a Copied or Cut Location Machine to a Group or a Test Point to a Location Machine or an Historical Record to a Test Point Once copied edit to suit if needed iv Delete any item in the route tree can be deleted using this function v Rename change the name of a Group Location Machine or Test Point vi Expand All If the data in the tree is collapsed expand it with this feature vii Collapse All If the tree is too large and needs to be collapsed use this viii Edit Preferences This opens a dialog box with the following tabs 1 General there are two options to select a Language Select from a list of languages here After the selection has been made the changes will occu
21. local drive usually C however if it is to be shared in a network you can locate that drive and enter the folder there The Descriptor format is 13 3 and 8 8 This will be used to describe identify both the location or machine and the test point or record number If you select 13 3 the location machine will have 13 alphanumeric characters while the record test point will be limited to 3 When done click OK D A new Plant Wizard window will open to create your Group data There are 3 ways to create your test Group 1 Default The default configuration is columns for Group Name Location Machine remember 13 or 8 characters and Point 3 or 8 characters If you want to view an example of what this will look like click on the Example box located in the top right corner of the window Copy from Group select this and a window will open for DMS Plants You can select one of the Plant folders open and select the file with the extension mdb The Group will open with the original data removed and will be ready for new data entry Copy from Excel If a Group has been created and saved in Excel you can locate and copy it to the new Plant Group If you want to view an example of what this will look like select the Example box located on the right next of the Copy From Excel box To copy click on the Copy From Excel box A window will open to help you select the path of the file After it is located click on the file and either double click
22. model is different and therefore DMS must be configured to the specific Ultraprobe being used for data transfer Configure Probes opens a Probe Manager window which will display a list of Ultraprobe instruments To configure a Probe a To adda new Ultraprobe click on the New button located on the bottom of the window to open the Wizard There are two methods of establishing the Ultraprobe for DMS recognition i Automatic Probe Detection With the Ultraprobe connected to the computer or the CF or SD card inserted into the computer DMS will search for the Ultraprobe and register it for future connections ii Manual Setup When selected the Manual Probe Setup Wizard will open Select the desired Ultraprobe click on Settings to create the communication protocol Enter the name and drive for the SD card CF card or USB port then select Next and DMS will test the connection When complete a confirmation will be displayed b If you want to remove an Ultraprobe displayed in the list highlight it and click on the Remove button located on the bottom of the window c If the Ultraprobe model you use is displayed in the list highlight it and check to be sure the listed drive is correct If not either i Remove the Ultraprobe and then select the New button located on the bottom of the window to configure the Ultraprobe ii Open the Settings box located on the Right side of the window and in the Name box delete the drive and enter the new drive l
23. ocation for 15 example if it read UP15000 on D and the actual location was C click in the box and highlight the drive and type in the correct drive 2 Selected Probe This will let you know which probe has been selected for communication with DMS If you use multiple probes it is recommended that you routinely check this before uploading and downloading data 3 Test Connection After an Ultraprobe has been connected to the computer make sure the data transfer will be successful Use Test Connection to be sure the CF SD or USB connection is working 4 Send Group to Probe To Upload a Group to an Ultraprobe 9000 10 000 or 15 000 a Be sure the Ultraprobe is connected or the appropriate memory card is inserted b Check to see that the Group to which you will place the data is highlighted in the tree on the left of the screen c Test the connection Upload Group e Window messages will read Loading Record _of__ followed by Upload Successful Opening Connection to Probe all files copied successfully f Click on OK The baseline data will be uploaded NOTE For instructions regarding uploading to an Ultraprobe refer to your instrument instructions 5 Retrieve Group from Probe To download a Group from an Ultraprobe 3000 9000 10 000 or 15 000 a Be sure the Ultraprobe is connected or the appropriate memory card is inserted b Check to see that the Group to which you will place the data i
24. or select OK When through click on OK Save to Excel When a Group has been created before exiting by clicking the OK button you may save it to Excel where you can use for future routes or edit and save for future use 17 E Alternative method There are three alternate methods to set a route w 92900 Fa gt o 1 Detailed 2 Basic 3 Raw Detailed all the necessary information for the Route will be entered It is advisable that before setting up a Route with details walk through the test areas to note the best way to proceed Look for areas that could complicate the inspection flow and adjust the sequencing of test points accordingly In DMS create Plant Application Group a Fill in the details as required in the Set up Wizard b If the data has previously existed in Excel that can be imported using the Copy from Excel box in the New Plant Wizard Upload the data to the appropriate Ultraprobe Perform the test following the Route Download the Data If new Location Machine or test points have not been entered in the original setup but were data logged the DMS data tree will add them Right click on each new item to rename g Ifthe test points or Location Machine are not in the desired sequence perform a Drag and Drop operation to move the item to the desired sequential location See section VI Drag and Drop 220 Basic In this method the inspection will be performed in the field with limited dat
25. per right side of the screen may be opened by clicking on them These are the tools to use after a route inspection has been performed a Record Information This tab brings the test record information to the screen It contains the test data for an historical record and therefore cannot be opened until a specific historical record located in the tree on the left side of the screen has been selected Record Information Images History Chart Alarm Reports i 7 Date Time Module Type Test Result Typical data viewed in an historical record 3 20 2008 6 21 33 PM sm oy ONE i i dB Frequency Inspector ID Temperature The information viewed is D zj 30 z 5 z Date Ti me od Sensitivity Info Ken i nT gt lype dB Frequency 0 40 English x NE x Mode the test mode used in the ene me ji E Instrument Real Time Peak Hold Pom ae ae DRIVEA Relative Sn ap shot Comments Tent Offset Value if offset has been used Serial Number refer to your instrument manual ole for details of both Mode and Offset WAE Value CAWAVE albgood wav A pen Alarm value Record Path ue MAPLE STREET Bearing Machine Room SYSTEMS INC Location Machine Taaa arik Comments enter relevant comments in the box WAV File if a sound is attached to the record it can be viewed using the open button Record Path To show where this record resides Module Type Inspector ID Meter Response how the intensity amp
26. port Create a report using only the data you want Select the Group you will use in the report Click on the Custom Report Box 3 The Select Fields dialog box opens Select each item you wish to use in the report Use the right pointing arrow button to add to the Included Columns box If you wish to remove an item you added to the Included Columns box highlight the item in the box then use the left pointing arrow button a To add all items in the left Available Columns box select the right pointing arrow All button To remove all items from the Included Columns box use the left pointing All button b To move an item up or down in the Included Columns box use the Up or Down button It will move an item up or down one space each time the button is selected 4 When through select the Next button 5 The Filter Rules Dialog box will open You have 3 choices a Export all data All your selected data will be exported without any filtering b Export Data that matches ANY rule Using ANY will allow for multiple filters that might not be related For example you might want to look at data from 2 groups It is inclusive For example you can use A and B and C and D Ss Export Wizard jr j Filter Rules Rules to decide which records will be exported Condition ctilf you would like to filter the exported data by one or more rules please enter your ru
27. r only after the program has been shut down and re opened b Display Alarm Groups This allows you to move the position of an Alarm group to either the top of the group data or below it If you do not want an Alarm Group to be displayed select Do not show Alarm Group Za Open a DMS Plant DMS Plants Folder C DMS Plants Plants Found EDDYVILLE EXCEL Fairchild General Mixer HBC MADIE STREET 14 2 Backup Settings To avoid missing or losing data this feature lets you select when to back up a database The backup will be performed before a selected action One or all can be selected The selected actions are a before Closing a Group b before Importing records c before Splitting a Group d before Dragging and Dropping 3 Paths The paths to DMS Plants Backups and Spectralyzer Paths are located here If any of these items are moved to another location or if DMS cannot find these paths identify where they reside Use the folder icon located next to any of the three items The Browse For Folder window will open to find the location for the link c COMMUNICATIONS This is the tab used for uploading or downloading data from the Ultraprobe Baseline data will be uploaded to the Ultraprobe 9000 10 000 and 15 000 Test results will be downloaded from the Ultraprobe 3000 9000 10 000 and 15 000 The Communications tab contains the following 1 Configure Probes Each Ultraprobe
28. ratrend DMS from your computer locate the file Ultratrend DMS v5 0 and extract the contents of the folder To install the program double click on setup exe and follow the instructions To install Ultratrend DMS from a CD insert the CD select My Computer select the appropriate disc drive and click on the Ultratrend DMS folder Click on the setup exe icon and follow the instructions Or open the Start and select the Run command then select setup exe and follow the instructions II DATABASE amp STORAGE LOCATION INFORMATION You must know where your Plant DMS Database is stored Ultratrend DMS 5 0 stores databases and related information in a folder called DMS Plants The default location for the DMS Plants is the C drive C DMS Plants The databases and other related information can be stored on another drive such as a network location by selecting a drive during installation by creating a new DMS Plants folder or by copying the DMS Plants folder to a drive of your choice If the location of the DMS Plants folder is changed after installation to locate go to the title bar Edit Paths and update the path This is the path DMS will look for when starting up To open a Plant choose File Open Plants i Open a DMS Plant DMS Plants Folder CADMS Plants Fa Plants Found EDDYVILLE EXCEL Fairchild General Mixer HBC MADI F STREET Cancel Browse to
29. s highlighted c Test the connection d Select Retrieve Group from Probe A window will open with a message Please select where to insert the downloaded records i There are three selections Plant Name Application Type and Group Name BE SURE TO check each selection box before continuing e When you are sure the data will be sent to the correct location f Select OK 6 Clear Instrument This will delete data from the Ultraprobe or Ultraprobe memory card Make sure the instrument is connected or the appropriate memory card is inserted in the computer Open Communications Select Clear Instrument 2 16 A message window will read Opening Connection to Probe Probe Data Cleared Select OK HELP This contains two items the Instruction Manual and About Ultratrend DMS About Ultratrend DMS will open a window with information about the version and contact information VI SETTING A ROUTE It is recommended that you clear any opened Plant before creating a new route To do this A Highlight the Plant right click and select Close Plant B Click on File and select New Plant C The New Plant Wizard will open 1 EO N 6 Create and enter a Plant Name Select an Application either click in the Application box or use the pull down arrow Create a Group Name Where will you be testing The DMS Plants Folder allows you to select where this Route will reside For example the program defaults to your
30. sh or SD cards one for each Route A Group contains a sequential set of records ranging from 1 to 400 These records reflect the information found in the 400 memory locations of the Ultraprobe A Group holds an unlimited number of History Information In the hierarchy structure A Group will be created under an Application When assigned to an Application the information collected will be placed in fields that relate solely to that specific Application for example the data fields for Bearing includes items such as Test Result Temperature while the data fields for Electric will include voltage humidity etc A Group may be re created in any of the 6 Applications To Create a new Group highlight Application then either select Edit New then Group or right click on an opened Application 1 Points Currently In Alarm A Points Currently In Test Points within a group that are in an Alarm state will be placed in a separate Group and identified with an icon displayed next to the heading Points Currently in Click on the to open and view any test points within the Group that have been selected as either in High Alarm or Low Alarm status This set of Points in Alarm can be moved from just above the Group data in the tree to below the group data or it may be removed This is performed by opening Edit and then selecting Preference Under General use the box titled Display Alarm Groups The change will happen
31. the location or the DMS Plants folder and click OK this will be shown in the top window Plants that are in the DMS folder will show in the bottom window Changing the location of a DMS Plant To change the location of a DMS Plant folder or to Backup or to define where Spectralyzer is located use the Edit Preferences Paths option located in Edit Preferences See the Edit Preferences section IHI FORMAT HIERARCHY Note To build a Route see Getting Started Ee Edu Comrmnenications Help A TA o MAPLE STREET Record Informabon images History Chan Alarm Reports l l Rearing i Group gt poeanana Date Tiene Module Type z Points Currently In 20 2008 621 pha STM Location Machine gt puwel ae e7 we Record Point gt ORIVEA 001 3 Vode e Respon Historical Record gt A202008 ea Pani Time 170 eum gt A PLANT A Plant is the top of the hierarchy A user can select an unlimited number of Plants All essential data is contained within the Plant which includes Application Group Location Machine Test Point the numbered location and Historical Records In order to view any of the components the Plant must be opened A Plant can contain only the 6 Applications listed below and an unlimited number of Groups and Locations To create a Plant Go to File select New Plant and use the New Plant Wizard B APPLICATION An Application determines the type of information to be uploade
32. to 4 will be included in the report vi Select the image or images vii In the pull down arrow you may select the image and the position in which you would like the image to set in the report as image 1 2 3 or 4 You may also select not to use the image 21 viii Click OK ix The Path file window will open select the path and name the report x Click OK xi Review your report Alarm Report This will produce test points that are in an alarm state It will be created in MS Excel To use this report effectively you must have set alarm levels in DMS Everything This report will include all the data entered in DMS for each test point There are two formats to select Excel or Text Spreadsheet csv Once saved the spreadsheet can be edited 4 To Generate one of the above reports 4 Leak i Select the report template you will use ii Click on the Generate Selected Report box iii Chose the path to the file window opens name the file and select the path iv A window will announce the report was successfully created Locate the file and review the results Just the data for test points in the alarm state Low or High will be displayed 1 Select the Group you will use for the report Pa 2 The Leak icon will be highlighted and a dropdown menu will appear uk 3 Your choices for the report include a Alarm Report This will produce test points that are in an alarm mode It will be created in MS Excel To use this report
33. ue Ultratrend DMS 5 0 YSTEMS ING Data Management System INSTRUCTION MANUAL 14 Hayes Street Elmsford NY 10523 PH 914 592 1220 Fax 914 347 2181 V 5 0 Ultratrend DMS Instruction Manual 5 0 Table of Contents Introduction Program Overview System Requirements Installation Database amp Storage Location Information Hierarchy Plant Application Group Groups Points in Alarm Sending Groups Points in Alarm to Ultraprobe 10 000 amp 15 000 Location Machine Record Plant Historical Record Image Attached Wave Attached Tabs Record Information Move a Record Adding a Record Images Adding an Image Deleting an Image Attaching Image to Record History tab Chart tab Alarms Reports IV Getting Started Understanding Features File Open Plant New Plant Save a Copy of Plant Close Plant Configure Lists Database Manager Edit Cut Copy Paste Delete Rename Expand All Collapse All Edit Preferences Communications Configure Probes Add New Ultraprobe Sending Groups Retrieving Groups Clear Instrument Help Setting a Route Drag amp Drop Viewing WAV files in UE Spectralyzer Creating Reports Help amp Contact ODDWAONNNDAAAHK WWW OW l OVERVIEW Introduction Ultratrend DMS is data organizing software for creating and maintaining databases that apply to all the basic applications performed by the Ultraprobe models 3000 9000 10 000 and 15 000 Users can select Generic inspections Bearings Leaks Val
34. ves Steam and Electrical applications It will store and organize records provide reports alarms and graphs Users will be able to transmit data from the Ultraprobe to a computer or from a computer to the Ultraprobe via a USB connection by Compact Flash Card Ultraprobe 10 000 or by an SD card Ultraprobe 15 000 Program Overview Ultratrend DMS is similar in appearance and operation to Windows Explorer providing users with a Record Hierarchy view of the data and the ability to sort organize and archive records The record hierarchy is Plant Application Group Location Machine Record Each Record will maintain fields which contain basic inspection data as well as a subsection for historical information The hierarchy design of the program provides users with the capability of ever expanding data management System requirements Hardware requirements e IBM PC or compatible Capable of running Windows XP XP Pro Vista e Windows 7 e 256 MB or higher e VGA monitor capable of displaying 256 colors e Mouse or other pointing device e Operating System requirements e Windows XP Vista or Windows 7 e 1 Gigabyte of RAM required 2 gigabytes recommended Installation Note Before installing Ultratrend DMS v 5 0 uninstall all older versions of Ultratrend DMS This will NOT delete your plant folder from the previous versions If you download from the Internet locate the file Ultratrend DMS v 5 0 For installation of Ult
35. when DMS is closed and re opened Sending Alarm Groups to an Ultraprobe Alarm Groups may be sent to the Ultraprobe 10 000 and to the Ultraprobe 15 000 To send an Alarm Group up to the Ultraprobe 10 000 or Ultraprobe 15 000 highlight the appropriate points currently in the Alarm state and select Send Group to Probe This action will send only the Baseline information from records that match the appropriate Test Points in Alarm level to the Ultraprobe These records will be stored sequentially in the Ultraprobe For example if records 5 amp 12 are in Alarm state they will show up as Record 1 amp 2 on the Ultraprobe After taking new readings for the Points in Alarm with the Ultraprobe 1 In Ultratrend DMS highlight the Group name again and select Retrieve Group from Probe 2 Ultratrend DMS will update the records and remove them from the Points in Alarm Group D LOCATION MACHINE This is the test subject It may contain one or more Test Points The Location Machine name may be set using 8 or 13 characters depending on how the test equipment and test point identification boxes are configured When creating a database it is important that you consider a name that will be understood by all users A Location is tied to a specific Group within a specific Application It will contain the Historical Records of each Test Point and must stay within the Application Note If there is a need to change the name of a Location Machine
36. wo formats to select Excel or Text Spreadsheet csv Once saved the spreadsheet can be edited 4 To Generate one of the above reports i Select the report template you will use ii Click on the Generate Selected Report box iii Chose the path to the file window opens name the file and select the path iv A window will announce the report was successfully created Locate the file and review the results Just the data for test points in the alarm state Low or High will be displayed 6 Valve 1 Select the Group you will use for the report cia 2 The Valve icon will be highlighted and a dropdown menu will appear 3 Your choices for the report include a Alarm Report This will produce test points that are in an alarm state It will be created in MS Excel To use this report effectively you must have set alarm levels in DMS 23 b Everything This report will include all the data entered in DMS for each test point There are two formats to select Excel or Text Spreadsheet csv Once saved the spreadsheet can be edited 4 To Generate one of the above reports i Select the report template you will use ii Click on the Generate Selected Report box iii Choose the path to the file window opens name the file and select the path iv A window will announce the report was successfully created Locate the file and review the results Just the data for test points in the alarm state Low or High will be displayed A Custom Re

Download Pdf Manuals