Home

TEE Transducer Care Philips Healthcare www.philips.com

image

Contents

1. WINDOW PLASTIC CAPS TIP BENDING NECK LATCH SHEATH KNOBS amp BREAKS PROXIMAL DISTAL HANDLE mip HANDLE HANDLE CONNECTOR CD Mktg 0001zs TEE Transducer Care document Page 2 of 4 Philips TEE Transducer Compatible Pre Cleaners Disinfectants amp Accessories for the UK Product Manufacturer supplier contact details Cleaners Control Housing and Cable T Spray Il Quat Ammonia Pharmaceutical Innovations pharminnovations com CIVCO Medical Solutions civco com Mana Tech Ltd UK distributer mana tech com Pre Cleaners and Cleaning agents Transducer shaft and tip Autozyme Puricore International Ltd puricore com NHS Supply Chain supplychain nhs uk BODE Chemie bode chemie com Bodedex H R Healthcare Ltd UK distributer email mike hoskins hrhealthcare co uk Cidezyme Enzol lt 5 CIVCO Medical Solutions civco com Mana Tech Ltd UK distributer mana tech com Neodisher Septo Pre Clean Dr Weigert orweigert co uk Gigazyme Schilke amp Mayr UK Ltd schuelke com NHS Supply Chain supplychain nhs uk Disinfectants Transducer shaft and tip RelyOn Perasafe Powder Antec International re yon dupont com NHS Supply Chain supplychain nhs uk Peracetic acid OCS Olympic Chemical Systems olympicchemicalsystems com Perastel compatible with Puricore AER Tristel Solutions Ltd tristel com Tristel Fuse for Instruments used with Stella
2. transducer car amp TEE Cleaning Procedure Power Procedure amp Point This information is to be used in conjunction with your institution s infection control procedure Disinfectants Transducer care Always follow the recommendations of disinfectant manufacturer Note Prior to disinfection the instrument should be cleaned using an enzymatic cleaner or mild soapy solution to remove any visible contaminate and then each element of the instrument disinfected according to the guidelines Procedure for disinfecting the TEE transducer by immersion 1 Disconnect the transducer from the system 2 Use the following procedure to remove all organic matter and other residue a Soak gauze pads in mild soapy water Do not use iodine based soaps b Wipe the distal tip and flexible shaft up to the control housing steering mechanism with the gauze pads Use an enzymatic cleaner to assist in removing protein residuals c Use water to rinse the distal tip and flexible shaft thoroughly Avoid wetting transducer hub 3 Check the transducer for any residual organic material Repeat Step 2 if necessary 4 Disinfect the distal tip and flexible shaft by placing them in the appropriate disinfectant Warning Do not soak the transducer for extended periods The transducer steering mechanism is not sealed if disinfectant or other fluid enters the steering mechanism it will corrode the gears and electrical connections 5 Remove the tip and sha
3. TEE Transducer Care DH i Li PS Philips Healthcare www philips com ultrasound Philips Customer Helpdesk 0870 5329741 TEE care including handling cleaning storing and disinfectant compatibility This checklist is your opportunity to verify that your facility has received training and will act as a reference to you 4 of training topics covered with relevant help function keywords in bold Note User information provided with system is the primary and best source of information Topic Notes e lel Objective By the end of the training users will be familiar with Philips recommendations for 7 User TEE Cleaning Procedure PDF Important information for TEE transducer care handout S8 3t Quick Materials Guide Operating Notes Getting Started System Help Information components Read this first Transducer For information on transducer general care handling cleaning storing amp disinfectant compatibility see Care System User manual amp Philips Transducer Care website www healthcare philips com main products ultrasound transducers transducer_care index wpd TEE Transducer Care Topic Notes Handling Handle the transducer with care Dropping or banging can cause serious damage TOE Use a tip guard on the transducer distal tip to protect the transducer s lens during transportation Accessories Always use a bite guard during studies A protective cover such as a disposable sheath should be used during studies TEE A
4. ccessories and Supplies Storage amp When not in use store the transducer in a TEE storage rack Use the carrying case to transport the Transport transducer Storage for transport Warning Do not bend the shaft into a circle with a diameter less than 0 3m 1ft Electrical Before use inspect the transducer for damage In the event of any sign of damage immediately Safety discontinue use Checking the TEE Transducer Electrical Safety Check Device available from Civco Medical Electrical TEE Transducer Specifications and Minimum Patient Weight Topic Notes Transducer Identify transducer flexible shaft and distal tip handle and steering mechanism cable and connector parts Spec amp Transducer specifications tip size patient weight guidelines Transducer descriptions Safety See table below TEE transducer specifications and minimum patient weight guidelines Probe Mode Model CIVCO Min patient Tip Length Tip weight kg mm Guard code X7 2t xMatrix 667 094 S7 2 Omni Ill 610 945 S7 3t Mini Multi 610 1009 S8 3t Micro TEE 610 1111 Please refer to System User manual CD Mktg 0001zs TEE Transducer Care document Page 1 of 4 TEE Transducer Cleaning and Disinfecting Topic Notes Correct See Disinfectants and Gels in the Getting Started Manual and User Manual Cleaning See User Materials Important information for TEE
5. d accepts that the topics detailed above have been covered during the training provided to the above key participants who now feel competent to operate the equipment in its intended clinical applications according to the Operators Manuals and to provide training to other users The checklist summary and evaluation form must be completed by customer and Philips representative and copies will be retained by both Authorised customer representative Signature Title Comments We trust that this training has been satisfactory Please feel free to comment in the space provided below Philips Healthcare would like to keep you informed about education courses they provide Please indicate if you give permission for us to put your email address on a central e mailing list by ticking the box next to your contact details CD Mktg 0001zs TEE Transducer Care document Page 4 of 4
6. ft from the disinfectant and thoroughly rinse with water according to the instructions from the disinfectant manufacturer Note some disinfectant manufacturers recommend rinsing by immersion in water 6 Dry the distal tip and flexible shaft with a sterile cloth or pad or allow to air dry 7 Lightly wipe only the steering mechanism and handle with a pad moistened with rubbing alcohol 70 isopropyl alcohol or using T Spray Il as directed 8 Clean the cable using a mild soap solution Quaternary Ammonium or Milton Do not use alcohol based products 9 Wipe the connector with bleach alcohol or Quaternary Ammonium based products Do not spray 10 Hang the transducer on a wall mounted rack and allow to air dry to complete procedure Cautions Do not rinse or immerse the handle or steering mechanism Do not rinse or immerse the cable or connector The use of 70 isopropyl alcohol on transducers is restricted to the handle only Do not use bleach or isopropyl alcohol based products on the transducer or shaft Never sterilize the transducer with autoclave ultraviolet gamma radiation gas steam or heat sterilization techniques Severe damage will result Fewer agents are compatible with Mini and Micro TEE See compatibility table Using non recommended disinfectants incorrect solution strength or immersing deeper or longer than recommended can damage or discolour the transducer Basic TEE parts PROXIMAL DISTAL BEAD
7. re Website www healthcare philips com main products ultrasound transducers transducer_care index wpd Caution Philips advises customers to follow instructions in the Philips User Manual or Transducer Care website for disinfectant compatibility with Philips Ultrasound devices The use of non recommended disinfectants may damage your transducer Avoidable transducer damage is not covered by warranty or service contract The use of non recommended disinfectant is done so at the customers own risk CD Mktg 0001zs TEE Transducer Care document Page 3 of 4 TEE Transducer Training Checklist Summary and Evaluation Institution Contact Person Phone Customer email address Address System Serial Configuration Number Date Project number applicable to installation training Trainer Name Email contact details Please send course info This training was related to an installation Yes No Please circle If additional non installation training please provide details After you have received your training please tick in the left column or mark N A not applicable Transoesophageal TEE Transducer Overview TEE Transducer Care TEE Transducer Specifications and Minimum Patient Weight Guidelines TEE Transducer Cleaning and Disinfecting and Cautions TEE Transducer Compatible Pre Cleaners Disinfectants Accessories and Automated Disinfectors for the UK The undersigne
8. semi automated decontamination device Tristel Solutions Ltd tristel com Tristel Sporicidal Wipes Tristel Solutions Ltd tristel com Accessories Tip protectors bite guards transducer covers sheaths storage racks and holders etc CIVCO Medical Solutions civco com Mana Tech Ltd UK distributer mana tech com 2Micro TEE transducer S8 3t Palmedic Probetection Cover Kit Product code 1280 02 Palmedic palmedic eu Leonhard Lang UK distributer email tony abbott leonhardlang co uk Storage cupboards Neocare neocare org uk Endoscope Storage Cabinet PuriCore International Ltd puricore com Automated Disinfectors Transducer shaft and tip C 10 Probetester Test and Disinfection equipment for US probes Optima Scandinavia AB tee probetester com SMC Limited Optima UK distributer email enquiries smcni com Automated Endoscope Reprocessor AER PuriCore International Ltd puricore com Important Note Fewer agents are compatible with the Mini Multi S7 3t and Micro TEE S8 3t transducers From the disinfectant group only RelyOn Perasafe Tristel Solutions Lid Tristel Fuse for Instruments and Tristel Sporicidal Wipes are compatible with these delicate transducers 7Palmedic Probetection Cover Kit Specifically designed Transducer cover kit for the Micro TEE S8 3t transducer For more information please contact your local Ultrasound Representative or access the Transducer Ca

Download Pdf Manuals

image

Related Search

Related Contents

Pansement absorbant lipido-colloïde micro-adhérent  le rapport d`expertise pré-définitif  LA PÉDICULOSE  User Manual - UC Agriculture and Natural Resources    View manual - Frigidaire  Netgear FS728TP User's Manual  FT TOTAL NETTOYANT INJECTEURS ET CARBURATEUR  Samsung SGH-X680 Manual de utilizare  Lenco MES-403  

Copyright © All rights reserved.