Home
Ziton Server
Contents
1. March 2006 Impro Technologies Data subject to change without notice Page 24 Impro Ziton Server User Manual Issue 1 Software Version V3 22
2. APPLICABILITY OF THIS MANUAL Design changes to the system may be made which do not affect this manual For this reason the software and firmware versions quoted here may differ from those in the system When a change occurs which affects this manual the manual issue number will change and the software and or firmware version quoted here will change appropriately Until that occurs these versions and any subsequent versions will be covered by this issue of the manual The last two digits of the standard Impro stock code indicate the issue status of the item concerned This manual is applicable to the Impro Ziton Server Software Module Version 1 00 onwards The next issue of this manual will determine the final software version to which this issue is applicable Please advise us of any errors or omissions in this manual to enable us to improve our service to you Thank you for choosing mpro products to implement your security or asset management systems Impro Technologies design and manufacture a wide range of technically advanced high quality reliable Access Control and Asset Identification and Management Systems Please contact your distributor to find out more about our products or advise us of your needs for specialised products not yet in our extensive and continually expanding range k Custman Impro Card Designen XP325 0 0 GB 00 Issue 1 March 2006 English Manuals impro_ziton_server usrm en 01 doc
3. I mproNet XP300 400 ZITON FIRE ALARM SERVER Version 3 22 SOFTWARE USER MANUAL Manual reference number XP325 0 0 GB 00 Issue 1 March 2006 IMPRO OFFICES WORLDWIDE I mpro Benelux BV Tel 31 20 497 3218 Fax 31 20 497 3952 E mail 5 louisd improbenelux nl ENG eng Website www improbenelux nl Address New Yorkstraat 45 47 Airport Business Park Lijnden 1175 RD Lijnden The Netherlands Tel 727 733 7061 Toll Free 800 390 5837 Fax 727 736 1031 E mail 5 info improus com Website www impro net Postal P O 607 Dunedin Address FL 34697 Physical 1177 Main Street Suite A Dunedin Address FL 34698 I mpro South Africa Tel 27 31 700 1087 Fax 5 27 31 700 1511 E mail impro impro net Website www impro net Postal P O Box 15407 Ashwood Address South Africa 3605 Physical 47 Gillitts Road Pinetown Address South Africa 3610 IMPORTANT NOTI CE In the event of any discrepancies in meaning between this the original English version of the manual and any other version of this manual in whatever language the information in this version shall take precedence March 2006 Impro Technologies Data subject to change without notice Page 2 Impro Ziton Server User Manual Issue 1 Software Version V3 22 IMPRO TECHNOLOGIES PTY LTD SOFTWARE LICENSE AGREEMENT READ THE TERMS AND CONDI
4. other names included therein are trademarks of Licensor No right License or interest to Licensor trademarks are generated hereunder and you agree that no such right License or interest shall be asserted by you with respect to such trademarks 9 GOVERNING LAW This License Agreement shall be construed and governed in accordance with the laws of Republic of South Africa 0 COSTS OF LITIGATION f any action is brought by either party to this License Agreement against the other party regarding the subject matter hereof the prevailing party shall be entitled to recover in addition to any other relief granted reasonable attorney fees and expenses 11 SEVERABILITY Should any item of the License Agreement be declared void or unenforceable to any court of competent jurisdiction such declaration shall have no effect on the remaining terms hereof 12 NO WAIVER The failure of either party to enforce any rights granted hereunder or to take action against the other party in the event of any breach hereunder shall not be deemed a waiver by that party as to subsequent enforcement of rights or subsequent actions in the event of future breaches 13 USE WITH 3 PARTY EQUIPMENT The use of this software with a card printer or any other 3rd party equipment is undertaken at the client s own risk Impro will not accept liability for any damage to such equipment caused by incompatibilities between Impro Technologies software and the
5. transfer pledge lease rent or share your rights under this License agreement 2 LICENSOR RIGHTS You acknowledge and agree that the Program consists of proprietary unpublished products of Licensor protected under Copyright Law and trade secret laws of general applicability You further acknowledge and agree that all right title and interest in and to the Program are and shall remain with Licensor This License Agreement does not convey to you an interest in or to the Program but only a imited right of use revocable in accordance with the terms of this LICENSE Agreement 3 LICENSE FEES The License fees paid by you are paid in consideration of the icenses granted under this License Agreement 4 TERM This License Agreement is effective upon your opening of his package 5 LIMITED WARRANTY Licensor warrants for your benefit alone that the program diskettes in which the computer software is embedded and he user s manual shall for a period of 90 days from the date of commencement of this License Agreement referred as the warranty period be free from defects in material and workmanship Licensor further warrants for our benefit alone that during the Warranty Period the Program shall operate substantially in accordance with he functional specifications in the User s Manual You agree that the oregoing constitutes your sole and exclusive remedy of breach by Licensor of any warranties made under this Agreement EXCEPT FOR TH
6. 1 Figure 12 Figure 13 Figure 14 Ziton Alarm Panels and Zones 9 Ziton I mproNet interface block diagram 11 Ziton ZP3 RS232 cable connector 65 12 Ziton ZP5 RS232 cable 25 pin to 25 pin D type connector pin outs 12 Ziton ZP5 RS232 cable 25 to 9 pin D type connector 13 Ziton Server dialog General Tab 5 14 Panel Setup oro er E 15 Add a new fire panel 00 16 Editing fire pariel dialOQgi iones 16 Panel deletion confirmation 17 Sensors on Panel 1 dialog een 17 Add new sensor dialog 2 0111 nnns 18 Help Menu Ziton Server 00 18 Help Info dialog 19 Figure 15 Alarms tab information enne nnnns 20 TABLES Table 1 Ziton Server main menu options 14 Impro website Technologies Pty Ltd http www impro net Reg No 90 06574 07 March 2006 Impro Technologies Data subject to change without notice Page 6 Impro Ziton Server User Manual Issue 1 Software Version V3 22 ZI SERVER SOFTWARE SCO
7. E WARRANTIES SET FORTH ABOVE THE PROGRAM AND THE SOFTWARE CONTAINED THEREIN ARE LICENSED 15 AND LICENSOR DISCLAIMS ANY AND ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 6 LIMITATION OF LIABILITY Licensor s cumulative liability to you or any other party for any loss or damages resulting from any claims demands or action arising out of or relating to this Agreement shall not exceed the License fee paid for the use of the Program In no event shall Licenser be liable for any indirect incidental consequential special or exemplary damages or lost profits even if Licenser has been advised of the possibility of such damages 7 HIGH RISK ACTIVITIES The software is not fault tolerant and is not designed manufactured or intended for use or resale as on line control equipment in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control direct life support machines or weapons systems in which the failure of the Software could lead directly to death personal injury or severe physical or environmental damage High Risk Activities and its suppliers specifically disclaim any express or implied warranty of itness for High Risk Activities 8 TRADEMARKS mproX ImproNet IXP and
8. L ImproNet System Software from Version 7 08 onwards includes a Ziton Server module This software allows alarm signals received from a Ziton ZP3 or ZP5 Panel or group of panels to be displayed on the ImproNet System Floor Plan s by the ImproNet Graphics Runtime software The Ziton Server software communicates with the ImproNet Graphics Runtime package The related ImproNet software consists of a Ziton Server which can communicate with a group of Ziton Fire Control Panels via an RS232 link One or more Impro Graphics Runtime packages can then connect to the Ziton Server in order to display alarms generated in the Ziton system These two Impro software programs can run on any machine on the network provided these have access to the ImproNet Database ELECTRICAL CONNECTIONS The electrical connections between each Ziton Panel or group of panels and the ImproNet System consist simply of an RS232 link from the main Ziton Panel to a PC that has access to the ImproNet Database The Ziton Server allows for the selection of a COM port and baud rate for this connection March 2006 Impro Technologies Data subject to change without notice Page 10 Impro Ziton Server User Manual Issue 1 Software Version V3 22 Hardware Block Diagram The connections between a Ziton Panel and an ImproNet System are shown in block diagram form in Figure 4 The only connection required is an RS 232 link Inputs from Ziton Fire PC with access to al
9. PE OF THIS MANUAL This document provides information about the integration of a Fire Alarm System based on one of two types of Ziton Alarm Panel with an ImproNet System The purpose of this integration is to allow alarm indications from one or more Ziton Alarm Panels to be displayed and acknowledged via the ImproNet Graphics Runtime software The alarms provided for in ImproNet are Fire Alarms The two Ziton panels concerned are the ZP3 and ZP5 Panels Such an alarm system would typically include one or more Ziton Panels and associated alarm sensors When using the 2 5 Panel it must be equipped with a 2 5 232 communications board to provide RS232 communications for connection to the ImproNet software The electrical connections required are described in this document This document does not provide any detailed information on programming the Ziton panel That information is part of the Ziton documentation ASSOCI ATED MANUALS Further information can be found in a Ziton ZP3 Fire Control Panel Manual b c d INTRODUCTI ON The Impro Ziton Server permits alarms from a Ziton Panel to be displayed and acknowledged from the graphics Floor Plan in an ImproNet System Ziton ZP5 Fire Control Panel Manual ImproNet Graphics Designer User Manual XP331 0 0 GB XX ImproNet Graphics Runtime User Manual IXP332 0 0 GB XX The Impro Ziton Server Software allows for the use of the Ziton ZP3 or ZP5 Panel in conjunction w
10. TIONS OF THIS LICENSE AGREEMENT CAREFULLY BEFORE OPENING THE PACKAGE CONTAINING THE PROGRAM DISKETTES OR CD ROM THE COMPUTER SOFTWARE THEREIN AND THE ACCOMPANYING USER DOCUMENTATION THE PROGRAM CONCERNING THE PROGRAM BETWEEN YOU AND IMPRO TECHNOLOGIES THIS LICENSE AGREEMENT REPRESENTS THE ENTIRE AGREEMENT PTY LTD THE LICENSOR AND IT SUPERSEDES ANY PRIOR PROPOSAL REPRESENTATION OR UNDERSTANDING BETWEEN THE PARTIES BY OPENING THE PACKAGE CONTAINING THE PROGRAM YOU AND YOUR COMPANY COLLECTIVELY YOU ARE ACCEPTING AND AGREEING TO THE TERMS OF THIS LICENSE AGREEMENT IF YOU ARE NOT WILLING TO BE BOUND BY THE TERMS OF THIS LICENSE AGREEMENT YOU SHOULD PROMPTLY RETURN THE PACKAGE IN UNOPENED FORM AND YOU WILL RECEIVE A REFUND OF YOUR MONEY 1 LICENSE GRANT Licenser hereby grants you and you accept a non exclusive license to use the Program CDROM and the computer software contained therein X object code only from collectively referred to as the Software and the accompanying User documentation only as authorised in this License Agreement The Software may be used only on a single computer owned leased or otherwise controlled by you or in the event of the in operability of that computer on a backup computer selected by you Concurrent use on two or more computers is not authorised without the advance written consent of Licenser and the payment of additional license fees You agree that you will not assign sublicense
11. Ziton ZP5 Fire Control Panel to a PC To connect a ZP5 Fire Control Panel to the PC an RS232 shielded cable with a 9 way female D type connector at one end and a 9 way or 25 way female D type connector at the other must be used see Figure 4 SHIELD SHIELD TD TD RD RD ae 5 mo RIS RTS Z om 20 2 CTS CTS g DSR DSR 19 28 GND DTR DTR ziton zp5 RS232 25d pin outs wmf 25 way D type 25 way D type female female Figure 4 Ziton ZP5 RS232 cable 25 pin to 25 pin D type connector pin outs See next page March 2006 Impro Technologies Data subject to change without notice Page 12 Impro Ziton Server User Manual Issue 1 Software Version V3 22 SHIELD 1 SHIELD TD 2 TD av RD 3 RD ww Qe 5 SS RTS 4 RTS OF aa CIS 5 cis NE DSR DSR GND 7 GND DTR 8 DTR ziton zp5 RS232 9d pin outs wmf 25 way D type 9 way D type female female Figure 5 Ziton ZP5 RS232 cable 25 pin to 9 pin D type connector pin outs ZI TON FI RE ALARM PANEL PROGRAMMI Certain configuration actions need to be made via the Ziton keypad panel to allow the software to communicate correctly Detailed programming information is included in the Ziton ZP3 and ZP5 Fire Control Panel Manuals You may need to ask your Ziton installer to program the Panel s CONFI GURATI ON OF THE ZITON SERVER SOFTWARE Ziton Server Software Configuration To configure the Zito
12. arm sensors Control Panel ImproNet Database Note 1 amp 2 NOTES 1 If the Ziton panel is type ZP3 it Inputs from connects directly to the PC alarm sensors Ziton Fire Control Panel 2 If the Ziton panel is type ZP5 it Note 3 connects via a ZP5 Comms Board to the PC 3 Other Ziton panels can be con nected to communicate with the PC via the first panel ziton zp3 alm mpronet conn wmf Inputs from Ziton Fire alarm sensors Control Panel Note 3 to other Ziton Fire Control Panels Figure 2 Ziton ImproNet interface block diagram RS232 Connection from a Ziton ZP3 Fire Control Panel to a PC This RS232 connection is made directly from ZP3 Panel to the PC using a shielded multi core cable refer to Figure 3 This cable requires a 9 way D type female connector at the ZP3 end and a 9 way or 25 way D type female connector at the PC end The cable is used to link the 9 way D type connector on the Ziton ZP3 Panel to a PC RS232 Comms port If necessary this link can be extended to a maximum of 10 m 10 94 yds March 2006 Impro Technologies Data subject to change without notice Page 11 Impro Ziton Server User Manual Issue 1 Software Version V3 22 9 way female Female D type connector D type 9 way OR 25 way 9 Go 9 Oe oe oc NS ziton zp3 RS232 pin outs wmf Figure 3 Ziton ZP3 RS232 cable connector pin outs RS232 Connection from a
13. e sensors see Figure 1 See next page March 2006 Impro Technologies Data subject to change without notice Page 8 Impro Ziton Server User Manual Issue 1 Software Version V3 22 Loop 1 ez S ensor ziton sample system wmf Figure 1 Ziton Alarm Panels and Zones concept Typically a Zone could be a department and a Super Zone the building containing that department Protocols Two protocols can be used within the Ziton Alarm System One is used when only one Ziton Panel is fitted and the other for multi panel systems where more than one panel is connected to a master panel a For single panel systems Protocol 07 ZCP2 Single Setup 57600 7 1 March 2006 Impro Technologies Data subject to change without notice Page 9 Impro Ziton Server User Manual Issue 1 Software Version V3 22 This indicates settings of 57600 baud 7 data bits even parity 1 stop bit b For multi panel systems Protocol ZCP2 Multi is similar and is intended to be used on multi panel systems where more than one panel is connected to a master panel PRELI MI NARY REQUI REMENTS The Ziton alarm system must be fully operational as a stand alone system before integrating it with the ImproNet System The following items must have been set up in the Ziton Panel Software before configuring the ImproNet software Sensor Names The names and locations of the Sensors must be known SERVER DESCRI PTI ON GENERA
14. ith the Impro Graphics Runtime package This Software is provided as part of the ImproNet System Software Suite from ImproNet V7 08 onwards CAUTI ON Do not attempt to use the Impro Ziton Server software when proprietary Ziton software is running March 2006 Impro Technologies Data subject to change without notice Page 7 Impro Ziton Server User Manual Issue 1 Software Version V3 22 GENERAL I NFORMATI DONGLES LI CENCI NG The Ziton Server does not need a dongle to run However each Graphics Runtime package needs to be unlocked via the ProxMate or similar unit to operate with the Ziton software ZI TON SYSTEM TERMI NOLOGY It is essential that you know the Ziton terminology listed here when integrating Ziton Panels with an ImproNet System NOTE The terms Panel Loop Super Zone and Zone used in this document have meanings specific to the Ziton System and are not related in any way to the same terms as used in ImproNet Panels Loops and Zones Each Ziton Alarm System can be divided into Zones and Super Zones Each Super Zone can contain several Zones see Figure 1 The Ziton Server is designed to manage Fire Alarms from the Ziton ZP3 or ZP5 Alram Control Panels Several sensors can be used in each Zone and each sensor is identified individually by the system so that the location of a fire can be accurately identified A Loop is a serial connection to a Ziton panel that includes one or mor
15. l Panel No 1 Name Save Figure 8 Add a new fire panel dialog 2 Select the required Panel No from the selection box 3 Type in the Name of the Panel in the box provided 4 Select Save or Cancel as required Edit Panel data 1 To edit data for a Panel highlight the appropriate line and click Edit 2 The Editing fire panel dialog shown in Figure 9 will be displayed 3 Change the Panel No if required from the selection box 4 Change the Panel Name if required by highlighting the existing text and entering the new text Editing fire panel Panel No 2 Name Factory fire alarms Save Figure 9 Editing fire panel dialog 5 Click Save or Cancel as required March 2006 Impro Technologies Data subject to change without notice Page 16 Impro Ziton Server User Manual Issue 1 Software Version V3 22 Delete Panel data 1 To delete Panel data select the line required in the Panel Setup dialog 2 Click Delete The dialog shown in Figure 10 will be displayed Confirm deletion of fire panel e This action can not be undone at a later stage When you delete this fire panel you will also delete all sensors that are associated with it The fire panel and all it s sensors will be removed from all Floorplans and any mappings will be discarded Are you sure you wish to continue and delete this Fire panel Figure 10 Panel deleti
16. n use the procedure below Comms Port Configuration 1 Select the Config option from the Ziton Server main menu 2 Select the Ports option This permits the selection of a Comms port from COMI to COM 8 3 Select the required Port and click OK 4 The default Port is COMI Baud Rate Configuration 1 Select the Config option from the Ziton Server main menu 2 Select the Baud option This permits the selection of a baud rate from these options 9 600 19 200 38 400 and 57 600 The default baud rate is 57 600 3 Select the required baud rate and click OK Panel Configuration To configure Fire Panels select View and then Panel The Panel Setup dialog shown in Figure 7 will be displayed Panel Setup Fire Panels Below is a list of fire panels that are currently configured 1 Admin Offices fire alarms 2 Factory fire alarms 2 rows loaded in 40ms Sensors Add p Edit Jj Delete Figure 7 Panel Setup dialog The Panel Setup dialog displays a list of the fire panels that are currently configured The operation of the Add Edit and Delete buttons is described next followed by the Sensors button March 2006 Impro Technologies Data subject to change without notice Page 15 Impro Ziton Server User Manual Issue 1 Software Version V3 22 Adding a new Panel 1 To add a new Fire Panel click Add The Add a new fire panel dialog shown in Figure 8 will be displayed Add new fire pane
17. n Server proceed as follows 1 Start the Ziton Server from install dir gt bin Ziton exe 2 The Ziton Server dialog shown in Figure 7 will be displayed See next page March 2006 Impro Technologies Data subject to change without notice Page 13 Impro Ziton Server User Manual Issue 1 Software Version V3 22 The Ziton Server Menus File Config View Help Server Information Below you will find information relating to this server A Alarms 2005 11 30 13 13 20 Database connection configured 2005 11 30 13 13 22 Server is up and running Shutdown Figure 6 Ziton Server dialog General Tab selected The Ziton Server Main Menu Bar includes the following options pale OPTION OPERATI ONS COMMENTS File Exit Exit Ziton Server Config Ports Select RS232 Comm Port from COM 1 to 8 Baud Select required baud rate View Panels Permits the configuration of Panels and Sensors Help About This dialog provides release date and version information and the options listed below INF Provides property and value information about software installed GC Used to release unused memory Table 1 Ziton Server main menu options March 2006 Impro Technologies Impro Ziton Server User Manual Issue 1 Data subject to change without notice Software Version V3 22 Page 14 CONFI GURATI ON PROCEDURE To configure the Ziton Server in a new applicatio
18. n Server dialog shown in Figure 13 will be displayed About Ziton Server Impro Technologies Ziton Server 3 22 Release 20051028 Windows 2000 and Java v1 4 2 09 Copyright 2 2000 2003 Impro Technologies Figure 13 Help Menu Ziton Server dialog March 2006 Impro Technologies Data subject to change without notice Page 18 Impro Ziton Server User Manual Issue 1 Software Version V3 22 3 Option INF provides data about the installed software an example is given in Figure 14 4 Option GC frees unused memory INFO sun awt windows Toolkit 1252 Figure 14 Help I nfo dialog USE OF THE ZI TON KEYPAD The Ziton Keypad is used to program the Ziton Panel and to manage the alarm system Further details are provided in the Ziton manuals CONFI GURATI ON OF THE GRAPHI CS SOFTWARE Graphics Runtime Software Configuration The configuration and acknowledgement of alarms from the Ziton equipment in the Graphics Runtime software is described in the Graphics Runtime Software User Manual Graphics Designer Software Configuration The configuration of Ziton alarm icons in the Graphics Designer software is described in the Graphics Designer Software User Manual March 2006 Impro Technologies Data subject to change without notice Page 19 Impro Ziton Server User Manual Issue 1 Software Version V3 22 ALARM INDICATIONS amp ACKNOWLEDGEMENT 1 To view Alarm Indications click the Ala
19. on confirmation dialog Sensors To display a list of sensors connected to a Panel 1 Highlight the Panel data by selecting a panel in the Panel Setup dialog for example Panel 1 2 Click Sensors A Sensors on Panel 1 dialog similar to that shown in Figure 11 will be displayed Sensors on Panel 1 Sensors Below is a list of sensors that are associated with this fire panel 1 Reception sensor Generic Sensor Office sensor Generic Sensor 2 rows loaded in Oms Figure 11 Sensors on Panel 1 dialog March 2006 Impro Technologies Data subject to change without notice Page 17 Impro Ziton Server User Manual Issue 1 Software Version V3 22 Adding a new Sensor 1 To add a Sensor click Add The Add new sensor dialog shown in Figure 12 will 2 3 4 5 6 be displayed Generic Sensor Loop No 189 Sensor No 1 Zone No 12 Super Zone No Guidance Text Save Cancel Figure 12 Add new sensor dialog Type the Sensor Name in the box provided Select a Sensor Type from the drop down menu Select the required Loop Sensor Zone and Super Zone numbers Type in Guidance Text if required in the box provided This text will appear in the Graphics Runtime when this alarm occurs Click Save or Cancel as required Help Menu 1 2 Select the Help option from the Main Menu Select About The About Zito
20. ontrol Panel to 12 ZITON FIRE ALARM PANEL 4 nnns 13 CONFIGURATION OF THE ZITON SERVER 13 Ziton Server Software 1 20021 eee 13 TheZiton Server M NUS sci cut eben ige eee ER 14 CONFIGURATION PROCEDURE essem eene nennen enne 15 Comms Port 1 eene 15 Baud Rate Configuration citet et eiie Digiti 15 Panel nennen nennen nennen nnn 15 Help Meri oer Re e etie pu ere utet ene 18 USE OF THE ZION KEYPAD 19 CONFIGURATION OF THE GRAPHICS 19 Graphics Runtime Software Configuration sss 19 Graphics Designer Software 19 ALARM INDICATIONS amp ACKNOWLEDGEMENT eH 20 APPLICABILITY OF THIS MANUAL t YR dtr tae eR 24 DI AGRAMS March 2006 Impro Technologies Data subject to change without notice Page 5 Impro Ziton Server User Manual Issue 1 Software Version V3 22 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 1
21. rms tab in the Server Information dialog Alarms information similar to that shown in Figure 15 will be displayed ioixi File Config View Help Server Information Below will find information relating to this server Log Alarms 2005 01 14 0 28 31 2005 01 11 02843 Figure 15 Alarms tab information 2 The Alarms tab displays details of each alarm condition received from the Ziton system 3 To acknowledge an alarm select the appropriate row in this screen The row will now be highlighted 4 Double click on the highlighted row A box with the word Acknowledge will be displayed next to the highlighted row select this box to acknowledge the Alarm 5 If all Alarms are acknowledged the associated Ziton Panel is silenced by the Ziton Server Software END March 2006 Impro Technologies Data subject to change without notice Page 20 Impro Ziton Server User Manual Issue 1 Software Version V3 22 USER S NOTES March 2006 Impro Technologies Data subject to change without notice Page 21 Impro Ziton Server User Manual Issue 1 Software Version V3 22 USER S NOTES March 2006 Impro Technologies Data subject to change without notice Page 22 Impro Ziton Server User Manual Issue 1 Software Version V3 22 USER S NOTES March 2006 Impro Technologies Data subject to change without notice Page 23 Impro Ziton Server User Manual Issue 1 Software Version V3 22 USER S NOTES
22. said equipment READ THI S BEFORE OPENI NG THE ENVELOPE CONTAINING THE SOFTWARE March 2006 Impro Technologies Impro Ziton Server User Manual Issue 1 Data subject to change without notice Page Software Version V3 22 March 2006 Impro Technologies Data subject to change without notice Page 4 Impro Ziton Server User Manual Issue 1 Software Version V3 22 I MPRO ZI TON SERVER SOFTWARE INSTALLATI ON AND CONFI GURATI ON CONTENTS ZITON SERVER SOPLWARE Duet tet e Re 7 SCOPE OF THIS MANUAL 7 ASSOCIATED MANUALS erret ttn hee dette nia rebar en re Poe 7 INTRODUCTION aha aaa amaaa a A dee tete eu dte rn qe ns 7 GENERAL INFORMATION ren Tope enean og od da 8 DONGLES EICENCING irit irre tente tni 8 SYSTEM TERMINOLOGY toned ied ep HI ect 8 Panels Loops ANd 27 11 ina A ANA aE nnne nnns 8 Protocols EDEN 9 PRELIMINARY REQUI REMENTS 2 Re prr e ar rene ae 10 5 I a T RR 10 SERVER DESCRIPTION inerenti ror edenda 10 GENERAL t RNase eet ete gs 10 ELECTRICAL CONNECTIONS i SER RAE RR 10 Hardware Block Diagram ist eer eie sri i 11 RS232 Connection from a Ziton ZP3 Fire Control Panel to a 11 RS232 Connection from a Ziton 2 5 Fire C
Download Pdf Manuals
Related Search
Related Contents
Philips Carry Case DLN1769 Atlus PERSONA 4 ARENA Samsung AR12FSSKABEN Instrukcja obsługi Real Decreto 56/1995 RAV-362-462UH-PE RAV-363-463AH8-PE Service Manual SECTION 1: INTRODUCTION 取扱説明書 - ダイニチ工業 Copyright © All rights reserved.