Home
Installation Manual
Contents
1. ANY WIRES CURRENTLY CONNECTED TO THE GARAGE DOOR OPENER USE WIRE TIES TO SECURE O EXCESS WIRING CLEAR OF ALL MOVING PARTS OF THE GARAGE DOOR AND OPENER 000 OOO CORRECTIVE ACTION Reset the GD00Z 4 by pressing the LINK button 5 times A quick beep then a longer beep indicates the reset Use this procedure only in the event that the network primary controller is missing or otherwise inoperable 1 Make sure the power supply is plugged in securely to a live outlet 2 Make sure the power cord is plugged in securely to the GD00Z 4 Make sure that there are no obstacles preventing the door from moving Make sure that the GD00Z 4 connection wires are connected to the proper terminals on the garage door opener Trace the wires from the garage door opener s pushbutton wall console to the door opener This is where the GD00Z 4 connection wires should be connected Make sure the tilt sensor is mounted correctly on the garage door with the arrow pointing up Make sure the battery pull tab has been removed from the tilt sensor 3 Replace the battery in the tilt sensor 8 SYSTEM OPERATION Restore power to your garage door opener To synchronize the system use the garage door opener s pushbutton to manually open and close the door STAY CLEAR OF THE DOOR Use your Z Wave Controller to activate your garage door opener The GD00Z 4 will beep and flash for f
2. SAFETY NOTES pPropuct DESCRIPTION GD00Z 4 Gocontrol e mew Z Wave Information e Z Wave is a registered trademark Z Wave technology Allows remote operation of a garage door opener using Z Wave controllers Acts as a Z Wave repeater to improve communications within the Z Wave mesh network A garage door opener remote lowe command transceiver with built in PLUS GD00Z 4 Summary of Operation GD00Z 4 connects to the garage door opener s pushbutton wall console terminals A wireless tilt sensor mounts on the garage door and reports the door s position to the GD00Z 4 GD00Z 4 responds to Z Wave commands from Z Wave controllers to open or close the garage door A warning indicator light flashes and a beeper sounds for 5 seconds before the door begins to move If the door does not completely open or close a second open or close command can be sent after 30 seconds If the door does not completely open or close after the second attempt the GD00Z 4 operation is suspended until a local garage door pushbutton is activated GARAGE DOOR OPENER REMOTE COMMAND TRANSCEIVER with TILT SENSOR LISTED DOOR OPERATOR Installation Instructions BF NORTEK SECURITY amp CONTROL USA amp Canada 800 421 1587 amp 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www nortekcontrol com PRODUCT COMPONENTS WARNING GD00Z 4 LIGHT of Sigma Designs Inc and or its subsidiaries Z Wave
3. be required to obtain warranty service This warranty shall not be extended or restarted upon receipt of any repaired or replacement part or product under this warranty No person is authorized to extend or otherwise modify this warranty How do I Obtain Warranty Service To obtain warranty service email our Returns Department at returns nortek com Include your name address telephone number the model number of your product a copy of your original sales receipt and a description of the problem Unless we need to discuss the situation further with you you will be emailed a Return Authorization Number and shipping instructions If we need to discuss the situation further with you we will call or email you NS amp C may require troubleshooting on installed product before a Return Authorization Number is issued Anything shipped to us without a Return Authorization Number willbe automatically returned unopened You are responsible for the charges for shipment to us unless you are a California resident Limitations THE DURATION OF ANY IMPLIED WARRANTY INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you NS amp C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY
4. AL SPECIAL HANDLING MAY APPLY SEE www dtsc ca gov hazardouswaste perchlorate KEEP AWAY FROM SMALL CHILDREN IF BATTERY IS SWALLOWED PROMPTLY SEE A DOCTOR DO NOT TRY TO RECHARGE THIS BATTERY DISPOSAL OF USED BATTERIES MUST BE MADE IN ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA GD00z 4 CONNECTIONS Plug the power cord into the power input jack on the GDO0Z 4 Connect the GD00Z 4 connection wires to the pushbutton wall console terminals on the garage door opener The terminals may be named PWC WC PB PUSHBUTTON or RED and WHITE Terminal names and locations vary by model GARAGE DOOR OPENER Either wire can connect to either terminal TROUBLESHOOTING PROBLEM Unable to include in Z Wave network The GDO00Z 4 does not flash or beep when activated The GD00Z 4 flashes and beeps when activated but the door does not move Garage door opens or closes but the status does not change on the Z Wave Controller POSSIBLE CAUSE GD00Z 4 was not properly excluded from a previous Z Wave network No power to the GD00Z 4 Obstruction blocking the door or incorrect wiring The tilt sensor signal is not being received by the GDOOZ 4 Remove the screw from 120 VAC outlet faceplate Secure the retaining bracket to the faceplate with the provided screw Snap the power supply into the bracket while plugging into the outlet DO NOT DISCONNECT
5. Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other legal rights which vary from State to State REGULATORY NOTICES Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Les changements ou modifications non approuv s express ment par la partie responsable de la conformit pourrait annuler autorit de l utilisateur a faire fonctionner l quipement This equipment has been tested and found to comply with the limits for Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipmen
6. entrapment detection system 5 PAIRING INCLUDING WITH THE SYSTEM Note Plug in the GD00Z 4 near your Z Wave Controller for these steps GD00Z 4 STATUS power NDICATOR D 3 INPUT Be Attach the mounting plate Snap the sensor onto oe lt tothe top panel of the door the mounting plate JACK y P LINK 5 lt a nelotthe CONNECTION SK kan T BUTTON S eee ARROWS ON PLATE WIRES D 0 amp SENSOR POINT UP MOUNTING SCREWS t ai a eae AND ANCHORS T O L I ane ire ee ARROWS T i I a OPTIONAL i pa Poston ADJUSTABLE GD00Z 4 MOUNTING Use double sided tape or BRACKET the two mounting screws supplied drill 1 16 pilot holes if required SUPPLY RETAINING BRACKET TO INCLUDE THE GD00Z 4 INTO YOUR CONTROLLER TO EXCLUDE THE GD00Z 4 FROM YOUR CONTROLLER Place your Z Wave Controller into Place your Z Wave Controller into Discovery or Include mode LOW BATTERY REPLACEMENT PLUS SIDE UP Exclude mode Insert the battery into the 1 transmitter S SCREW AND MOUNTING HARDWARE FOR ADJUSTABLE BRACKET The system will notify you when the battery is low replace the battery with Press and release the link button a type CR2032 coin cell Press and release the link button on the GD00Z 4 SCREW FOR on the GD00Z 4 POWER SUPPLY BRACKET Confirm that the GD00Z 4 was recognized by your Z Wave Controller Confirm that the GD00Z 4 was excl
7. is an Interoperable two way RF mesh networking technology designed for use with a Z Wave gateway controller and other Z Wave enabled devices Replication is the process of copying or transferring your Z Wave network from one controller to another This is a Security enabled Z Wave product and must be used with a Security enabled Z Wave controller in order to fully utilize this product As such this device will not respond to Basic CC commands ASSOCIATION The GD00Z 4 supports 1 Group with 1 Node Group 1 must be assigned the Node ID of the controller to which unsolicited notifications from the GD00Z 4 will be sent The Z Wave controller should set this association automatically after inclusion O TILT SENSOR INSTALLATION AND BATTERY To activate the tilt sensor remove the battery protection pull strip This operator system is equipped with an unattended operation feature This door could move unexpectedly NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR A WARNING A This system can be installed on sectional type roll up doors only per UL 325 DO NOT INSTALL ON ONE PIECE DOORS A WARNING A The Remote Command Transceiver must be mounted in the garage in sight of the garage door where the visual and audible movement warning indicators can be clearly seen and heard A WARNING A Do not install the Remote Command Transceiver on garage door operators manufactured prior to 1993 models without an operational safety beam
8. ive seconds before the door moves The GD00Z 4 will activate the door opener and open or close the door STAY CLEAR OF THE DOOR NORTEK SECURITY amp CONTROL LIMITED WARRANTY What is Covered Nortek Security amp Control NS amp C warrants to consumers who purchase this product for personal family or household purposes new irom NS amp C directly or from an authorized NS amp C dealer that the product will be free from defects in materials and workmanship for a period of uj ear from the date of purchase This warranty only applies if the product is installed at a residence in the 50 United States or District of Columbia and gayat the site of the original installation It is not transferable This warranty is not extended to resellers If a defect exists NS amp C will have you ship the defective part or product to us and we will at our option either repair or replace it This warranty does not cover defects or damages caused by improper handling maintenance storage installation removal or re installation misuse jnon factory authorized modification or alteration use of incompatible accessories electrical power problems or surges impact by foreign obiecte accident fire acts of God normal wear and tear or shipping damage other than a shipmenttrom NS amp C Note that all NS amp C products are designed to be installed removed and serviced by trained individuals or professionals Keep your original sales receipt as it will
9. t into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada 236956 BX2 Copyright 2015 Nortek Security amp Control LLC
10. ton wall console Once the GD00Z 4 has initiated the movement of the garage door another command cannot be sent for 30 seconds This eliminates the chance of bouncing the garage door and possibly damaging the garage door opener GD002Z 4 Specifications Power Supply Operating Temperature Audible Alarm Strobe Communications Mounting Input 120 VAC 0 8 A Output 12 VDC 2A 4 122 F 20 50 C 45 db 10 feet 360 Lumens Z Wave 908 4 MHz Screws and anchors to the ceiling or bracket to the opener s hanging hardware Tilt Sensor Specifications Power Supply Operating Temperature Battery Life Communications Range Mounting to Garage Door Type CR2032 Coin Cell Battery 4 122 F 20 50 C 24 Months typical Proprietary 345 MHz 100 feet line of sight to GDO0Z 4 Double sided tape or two mounting screws Specifications subject to change without notice kd wal The optional adjustable mounting bracket fits 3 ways on the GD00Z 4 The bracket snaps onto indents on either side or on the end of the GD00Z 4 Use the bolts and nuts supplied to attach the bracket to a secure structure BE SURE THE GD002 4 IS CLEAR OF ALL MOVING PARTS OF THE GARAGE DOOR AND THE WARNING LAMP IS NOT OBSTRUCTED NOTICE TO USERS IN CALIFORNIA CR COIN CELL LITHIUM BATTERY INFORMATION THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM BATTERY WHICH CONTAINS PERCHLORATE MATERI
11. uded by your Z Wave Controller To open the case twist a small screwdriver in case slot POWER SUPPLY Refer to your Z Wave Controllers instructions for additional information on including devices Refer to your Z Wave Controllers instructions for additional information on excluding devices SCREWS AND MOUNTING TAPE FOR TILT SENSOR GD00Z 4 MOUNTING Tilt sensor mounted on he top panel ol mounts on the ceiling The GD00Z 4 typically REMOVE POWER FROM THE GARAGE DOOR OPENER BEFORE CONTINUING near the opener and the power outlet WARNING THE GD00Z 4 WARNING LAMP MUST BE VISIBLE IN ALL DOOR POSITIONS THE GD00Z 4 CAN ALSO BE ATTACHED TO THE OPENER S HARDWARE USING THE ADJUSTABLE MOUNTING BRACKET Secure bracket with screw Use the four screws and anchors to mount INDENT the GD00Z 4 above the opener P a 3 16 HOLES d FOR ANCHORS 7 OPERATION NOTES 1 The warning light will flash and the warning beeper will sound for five seconds before the door opener is activated STAY CLEAR OF THE DOOR AND DOOR OPENER THEY ARE ABOUT TO MOVE If the door does not completely open or close after remote activation the GD00Z 4 will allow user to try to operate the door one more time If the second attempt fails the GD00Z 4 will go into lock out mode See Note 3 If the GD00Z 4 is in lock out mode and will not accept remote commands activate the door from the pushbut
Download Pdf Manuals
Related Search
Related Contents
Terex Z-Booms Specsheets FR.indd ACD Call Guide User Manual Simpli Home INT-AXCSM-BNCH-EB Instructions / Assembly Samsung SGH-P730 User Manual 65110 - 1 HP Dust Collector w/ Parts Breakdown USER MANUAL Lithonia Lighting IBH 11L MV Installation Guide pdf:226KB - 中国四国産業保安監督部 DS90 Marmitek IHM TP700 Comfort - Patrick MONASSIER Copyright © All rights reserved.