ALTERNATING PRESSURE PUMP AND
Contents
1. 4 Use the hangers to hang the pump on the bed s foot end as shown above adjust the hangers to place the pump in the most upright position or place the pump on a flat surface easily accessible to the caregiver and or doctor A NOTICE Place the pump in a position where the caregiver and or doctor can access it easily 5 Connect mattress overlay s quick connectors to pump Ensure connectors are secure before continuing 14025 INS LAB RevB11 11 A NOTICE Check to ensure the air hoses are not kinked or tucked under mattress or overlay A NOTICE Locate all cords so that they will not be stepped on tripped over or otherwise subjected to damage or stress N WARNING Do not use a household extension cord if the electrical cord does not reach the power outlet Use of an improper extension cord could result in fire and electric shock If an extension cord must be used use a three conductor cord with ground properly wired in good electrical condition and keep it as short as possible N WARNING This device which MUST be grounded is equipped with a cord that has a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded A NOTICE Ensure the pump unit is suitable for the local power voltage 6 Plug the power cord into a properly grounded electrical outlet A NOTICE Use the pump only with the mattress overlay recommended by the manufacturer Do not use it f
2. Front Panel D normal pressure indicator low pressure indicator ON OFF switch Ib T control dial pump front panel Front panel pressure control dial The pressure control dial controls the air pressure output To increase pressure turn the dial clockwise To decrease pressure turn the dial counter clockwise ON OFF switch The ON OFF switch turns the main power on and off Normal pressure indicator When the normal pressure indicator green LED illuminates pressure inside mattress overlay has reached the preset pressure setting Low pressure indicator When the low pressure indicator yellow LED illuminates pressure inside mattress overlay is below normal Please refer to TROUBLESHOOTING Pump Rear ye rear power cord 10 14025 INS LAB RevB11 pump INSTALLATION UNPACKING Unpack the box to inspect for any damage which may have occurred during shipment If there is any damage please contact your authorized distributor immediately PUMP AND MATTRESS OVERLAY INSTALLATION wire hanger 3G S y end foot end mattress overlay a mattress installation 1 Remove all sheets blankets and pillows from the bed 2 Place the mattress overlay on top of the mattress with the foot end oriented as shown above Tuck overlay s mattress extensions under the mattress to secure over lay to mattress 3 Fold open the wire hangers on the back of the pump as shown above
3. SAFETY PRECAUTIONS The safety statements presented in this chapter refer to the basic safety information that should be observed by those using this Mattress Overlay System There are ad ditional safety statements in other chapters or sections which may be the same as or similar to the following or specific to the operations N DANGER Indicates an imminent hazard situation that if not avoided will result in death or serious injury N WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious injury N CAUTION Indicates a potential hazard or unsafe practice that if not avoided could result in minor or moderate personal injury A NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information to ensure that you get the most from your product DANGER To reduce the risk of electrocution N DANGER Always unplug this product immediately after use Z DANGER Do not use this product while bathing N DANGER Do not place or store this product where it can fall or be pulled into a tub or sink N DANGER Do not place this product in or drop into water or other liquid N DANGER Do not reach for a product that has fallen into water Unplug it immediately 14025 INS LAB RevB1 1 5 WARNING To reduce the risk of burns electrocut
4. LLIIVIEX A Graham Field Brand ALTERNATING PRESSURE PUMP AND MATTRESS OVERLAY SYSTEM MODEL 11025 USER MANUAL Important Do not operate the Mattress Overlay System without first reading and understanding this manual Save this manual for future use Info The most current version of this manual can be found online at www grahamfield com 14025 INS LAB ReuB11 CONTENTS INTRODUCTION nneemmnnnnnnenmnnnnnnenmnnnnnnnmnennnnnennnnnnn te 3 INTENDED USE aaa 3 EQUIPMENT SYMBOLS u s 3 TEST STANDARDS 4 IMPORTANT SAFETY PRECAUTIONS 5 DANGER M 5 WARNING ulama 6 N 7 PRODUCT DESCRIPTION 8 PUMP AND MATTRESS OVERLAY SYSTEM is 8 J 9 PUMP FRONT PANEL 10 PUMP REAR 1a 10 NSAAIOJJJJ 11 UNPACKING 11 PUMP AND MATTRESS OVERLAY INSTALLATION 11 OPERATION 0 namana 13 PRESSURE ADJUSTMENT u s 14 LOW PRESSURE FAULT CONDITION ee 14 QUICK DISCONNECT L A 15 CPR FUNCTION 15 NMAINTEMNAMNCE 16 ez ulcer 16 L 16 MATTRESS OVERI AM 16 GENERAL MAINTENANCE aa 16 STORAGE 16 TROUBLESHOOTING a 17 SPECIFICATIONS 18 PUMP aaa 18 MATTRESS OVERLAY aa 18 Lu Lnul g 19 Graham Field and Lumex are registered trademarks of GF Health Products Inc GF Health Products Inc Graham Field is not responsible for typog
5. NTENANCE CLEANING Perform the following cleaning procedures before use and as necessary thereafter Pump Wipe the pump with a clean damp cloth and mild deter gent and keep it away from dust Air dry A NOTICE Do not use corrosive or powdered cleansers to clean the pump A NOTICE Do not immerse or soak the pump A NOTICE Do not clean with phenolic products Mattress Overlay Wipe the mattress overlay with a clean damp cloth and mild detergent The mattress overlay may also be cleaned using a 10 solution of sodium hypochlorite bleach di luted in water Air dry thoroughly before use A NOTICE Do not clean with phenolic products A NOTICE After cleaning air dry the mattress overlay without direct exposure to sunlight GENERAL MAINTENANCE 1 Check power cord and plug for abrasion or excessive wear 2 Check mattress overlay for signs of wear or damage En sure air tubes are firmly secured to pump connectors 3 Check the air hoses for kinks or breaks For replace ment please contact your GF authorized distributor STORAGE 1 To store lay the mattress overlay out flat and upside down 2 Roll from the head end toward the foot end 3 Store mattress overlay and pump in a dust free environ ment with no exposure to direct sunlight 16 14025 INS LAB RevB11 TROUBLESHOOTING Problem Solution O Power is not ON Ensure the power cord is connected to main power Low pressure indicator is illuminate
6. d Patient is bottoming out Mattress overlay is not secured No air produced from some air outlets of the air tube connector Ensure connections between air hose connectors and pump are tightly secured Ensure all tubing hose connections along mattress overlay are tightly secured Ensure CPR valves are sealed Ensure there are no air cell leaks Pressure setting could be inadequate for the patient adjust pressure to higher level and wait for a few minutes Ensure all the snap buttons are securely fastened Ensure the mattress overlay extension sheets are tucked under the mattress This is normal during alternating mode Air outlets take turns producing air during preset cycle time Info If the above information does not answer your questions please contact your GF authorized distributor for further assistance 14025 INS LAB RevB1 1 17 SPECIFICATIONS Info Specifications are subject to change without notice PUMP Item Specification Power Supply 120V AC 60 Hz 1A See rating label on product Pump Unit Dimensions 10 x 5 1 x 3 7 25 4cm x 13cm x 9 5cm Weight 3 51 1 6 kg Environment Temperature Operation 50 F to 104 F 10 C to 40 C Storage 5 F to 122 F 15 C to 50 C Shipping 5 F to 158 F 15 C to 70 C Humidity Operation 10 to 90 RH non condensing Storage 10 to 90 RH non condensing Shipping 10 to 90 RH non condensing Classi
7. e the setting If your fingers do not fit well increase the setting two notches firmer Wait ten minutes and then check again You should only have to ad just this setting one time per patient Please consult your physician for an appropriate setting Low Pressure Fault Condition Info When abnormal low pressure occurs not during setup while the mattress overlay is filling the low pressure indicator yellow LED will illuminate Ensure all connectors are connected properly and that they are correctly installed per instructions The low pressure indicator will illuminate until the low pressure fault condition is resolved at which time the low pressure indicator will de illuminate and the normal pressure indicator will illuminate A NOTICE If the pressure level is consistently low check for leakage in tubes and or connecting hoses If necessary replace any damaged hoses Contact your GF authorized distributor for repair 14 14025 INS LAB RevB11 QUICK DISCONNECT Pull the power plug from the wall connector to disconnect the device quickly CPR FUNCTION If CPR must be performed on the patient while the mat tress is in use to immediately deflate the mattress either l Pull the CPR valves from the mattress in the location of the ar row shown at right or Disconnect the quick connector from the CPR valves pump in the location bo of the arrow shown at quick connectors right 14025 INS LAB RevB11 15 MAI
8. edding and any accessories added to the bed can all affect the risk of entrapment Thorough patient assessment and monitoring are necessary to reduce the risk of entrapment including establishing whether the use of a bed rail is in the best interest of the patient Read and understand the User Manual before using this equipment GF Health Products Inc product manuals are available online at www grahamfield com Visit the FDA s Bed Safety page at www fda gov to learn more about the risks of entrapment It is the responsibility of the facility and provider to be in compliance with these guidelines Refer to user manuals for beds and rails for additional product safety information After any adjustment repair or service and before use ensure all attaching hardware is securely tightened Bed rails with dimensions different than the original equipment specified by the bed manufacturer may not be interchangeable and may result in entrapment or other injury NOTICE A NOTICE Ensure the pump unit is suitable for local power voltage A NOTICE The pump can be used only with the accompanying mattress Do not use it for any other purpose 14025 INS LAB RevB11 7 PRODUCT DESCRIPTION PUMP AND MATTRESS OVERLAY SYSTEM CPR valves mattress overlay quick connectors pump 8 14025 INS LAB RevB11 PUMP front wire hangers air tube connectors quick connectors pump 14025 INS LAB RevB1 1 Pump
9. fication e Class I Type BF IPX0 Applied part Air Mattress Not suitable for use in the presence of a flammable anesthetic mixture No AP or APG protection MATTRESS OVERLAY item Specification Dimensions Lx WxH 78 7 x 35 4 x 5 200cm x 90cm x 12 7cm Pressure Range mmHg 40 90 18 14025 INS LAB RevB11 WARRANTY GF Health Products Inc warrants the Lumex Model 14025 Alternating Pressure Pump and Mattress Overlay System for a period of one year for defects in workmanship and materials If a product is deemed to be under warranty GF Health Products Inc shall provide at its option 1 re placement of any defective part or product or 2 a credit of the original selling price made to GF Health Products Inc s initial customer The warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc The warranties contained herein contain all the represen tations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation as sertion guarantee warranty collateral contract or other assurance except those set out in this document 14025 INS LAB RevB11 19 USA Corporate Headquarters GF Health Prod
10. ion fire or personal injury WARNING Do not leave this product unattended when plugged in Z WARNING Always use close supervision when this product is used by on or near children or those who require close supervision WARNING Use this product only as intended and described in this manual Do not use attachments or accessories not recommended by GF Health Products Inc N WARNING Never operate this product if a It has a damaged cord or plug b It is not working properly c It has been dropped or damaged d It has been dropped into water Return the product to your GF authorized distributor N WARNING Keep the cord away from heated surfaces N WARNING Never block the air openings of this product or place it on a soft surface such as a bed or couch where the openings may be blocked Keep the air opening free of lint hair and other similar particles N WARNING Never drop or insert any object into any opening or hose WARNING Do not use this product in the presence of flammable anesthesia or where oxygen or nitrous oxide is being administered N WARNING Connect this product only to a properly grounded power outlet N WARNING Maximum patient weight capacity for this product is 265 Ib 120 kg 6 14025 INS LAB RevB1 1 WARNING Patient entrapment with bed side rails may cause injury or death The bed frame and its components including the mattress bed side rails head and foot board b
11. or any other purpose 12 14025 INS LAB RevB1 1 OPERATION 1 Turn the power switch to the ON position 2 Adjust the pressure adjust knob to the maximum position Info Always set the pressure adjust knob to the maximum position for the quickest inflation at set up the mattress overlay can then be adjusted to the desired pressure 3 The pump will begin delivering air into the mattress overlay While the mattress is filling the D low pressure indicator yellow LED will illuminate O 4 When the selected pressure level is reached the low pres sure indicator will de illuminate and the normal pressure indica o tor green LED will automati cally illuminate 5 Replace all sheets blankets and pillows on the bed 14025 INS LAB RevB11 13 PRESSURE ADJUSTMENT Generally a lighter patient will need a lower softer set ting while a heavier patient will need a higher firmer setting but pressure adjustment must ultimately be based on the patient s weight distribution A short stocky person may be the same weight as a tall thin person but their settings will not be the same The mattress should be firm enough to support the patient yet soft enough so the pa tient will sink down to eliminate pressure points Test the pressure by placing three fingers below the mattress under the patient s buttock area your fingers should just fit If the fit is too loose decreas
12. raphi cal errors Packaging warranties specifications and products are subject to change without notice 2 14025 INS LAB RevB1 1 INTRODUCTION Use this manual for initial setup and operation of the Lumex Model 14025 Alternating Pressure Pump and Mattress Overlay System Read all instructions before using the mattress overlay system and save this manual for future reference INTENDED USE This product is intended to reduce the incidence of pres sure ulcers while optimizing patient comfort It is also use ful for the following purposes e Individual home care setting and long term care of those suffering from pressure ulcers e Pain management as prescribed by a physician EQUIPMENT SYMBOLS BF symbol Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment information with regard to returning and recycling this product please consult your local city office household waste disposal service or GF authorized distributor Disposal of Electrical amp Electronic Equipment WEEE Do not treat this product as household waste For more detailed Sa 14025 INS LAB RevB11 3 TEST STANDARDS This product has been tested and successfully approved with the following standards ForUSA UL 1434 For Europe EN 60601 1 EN 60601 1 2 EN 55011 Class B EN 61000 3 2 EN 61000 3 3 IEC 801 2 IEC 801 3 IEC 801 4 IEC 801 5 4 14025 INS LAB RevB11 IMPORTANT
13. ucts Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 770 368 4700 GRAHAM FIELD www grahamfield com 2011 GF Health Products Inc