Home

DIAPro LED Battery Wash Beam IP65

image

Contents

1. Return all settings to factory defaults DMX512 Controller Mode 1 Setting DMX512 Address DMX ADDRESS 001 512 2 Setting Channels CONTROL MODE ADVANCED BASIS NORMAL 3 WDMX control PERSONALITY gt WDMX ON OFF RESET If the unit is successfully connected in the home display the sign Appears If the unit is not connected to a transmitter or switched off no sign is visible E ED DMX512 Channel Values ADV BAS NOR Description 245 255 Electronic shutter effect Shutter closed Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast slow Shutter open Strobe 10 sine wave pulse fast slow Shutter open 000 255 Dimmer 0 100 wN 000 255 ZOOM 0 100 000 255 Color wheel rotation effect 000 255 Red 0 100 000 255 Green 0 100 000 255 Blue 0 100 o JA o N 000 255 White 0 100 Oo NIOJ ony A gt Er aad eal Er 000 255 Color temperature 2500K 10000K 000 255
2. Safety Cable Note the cable must be i d through the heat Hanging Clamp secured fhrc Note sold sink ventilation separately passageway Connection of DMX Signal Wire 1 Please use the fixture controller wire specially when use the DMX512 Controller Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture Connect the end of the cable coming from the first fixture which will have a male 3 pin connector to the input connector of the next fixture consisting of a female 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on This product can be connected numerous lamps in series without the need for the signal amplifier the signal will not be weakened 3 PIN TO 5 PIN CONVERSION CHART Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter 3 PIN TO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin2 Pin2 Data signal Pin 3 Pin 3 Do not use Do notuse Do notuse Do notuse 4 OPERATING INSTRUCTIONS Control Panel Functions MODE ENTER BUTTON FUNCTION UP Holding down the UP or DOWN button for more than 3 seconds the MENU display rotated 180 DOWN MODE Exits fro
3. AUTO 0 10 000 255 AUTO SPEED 000 255 DIMMER SPEED s B 11 12 s 0958
4. Show Atelier DIAPro LED Battery Wash Beam IP65 ifero USER MANUAL s a 1 2 8 1 BEFORE YOU BEGIN What is included 1xFixture 1x Power cable with plug 1xUser Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC POWER This fixture has an auto switching switch mode power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unitis to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz Each lightis connected end to end by the power socket POWER IN and POWER OUT on the light or use the waterproof power cord Please ensure the head and the tail tightening when connect the lights to preventthe power leakage occurred by water seepage to the plug Help preserve the environment Ensure that this product is recycled atthe end ofits lif
5. ambient temperature 40 C Do not operate fixture at temperatures higher than this Never connect the device to a dimmer pack 2 INTRODUCTION Specifications e Voltage Rating AC100V 240V 50 60Hz Power Rating 50W LED Quantity 4x10 W RGBW Lens 8 40 Zoom Ingress Protection IP65 indoor option Product Size 240x191x286mm N W 6Kgs Battery Duration 9 hours full white 20 hours color fade e 4 hour fast charge from flight case e 8 hours in slow charge with PowerCon More than 1 000 charge deplete cycles No memory effect Noacid leaks Dimensions 3 SETUP Installation Requirement This product can be used in a variety of situations can hang and put on the ground If hanging the fixture for over head use then please follow the below steps Please choose the suitable location to put or hang the light when installing it You must use the exclusive clamp hanger and screw when hanging it and make sure the weight of the light is within limits of the hanger Please make sure without any flammable objects within 0 5m when installing the light The installation should be operated by professional person any irregular installation will cause the body injury or equipment damage Block access below the work area and use suitable and stable platform when installing or servicing fixture
6. e Your supplier can give details of local arrangements for the disposal of products Safety Instructions WARNING Please read these instructions carefully which includes important information about the installation usage and maintenance of this product The following symbols are used to identify important safety information on the product and in this manual A DANGER DANGER WARNING WARNING WARNING Safety hazard Hazardous Fire hazard LED light Refer to user Riskofsevere Voltage Risk of emission Risk injury or death lethal or severe ofeye injury electric shock This light belongs to grade protection device therefore the light must connect to the earth excellently And the power connection must be operated by the professional technician Make sure that the working voltage will not higher or lower than the rated value Make sure that the cable didn t be damage or lacerated by sharp The light must be power off when it s standing idle or before clearing The cable must with plug and you must pull out the cable by handle the plug Please be careful when installing the lighting Never touch the bared cable or it will cause the deadly electric shock Please use the suitable and safe cable to connect the light Please never remodel the light randomly we will not take the guarantee for the faulty and damage which caused by dismantle repair or remodel of the nonprofessional person Maximum
7. m the current menu or function UP value when in a function Navigates upwards through the menu list and increases the numeric DOWN Navigates downwards through the menu list and decreases the numeric value when in a function ENTER Enables the currently displayed menu or sets the currently selected value in to the selected function MAIN SUB FUNCTION FUNCTION SELECTION INSTRUCTION DMX ADDRESS 001 512 Set DMX start address CONTROL ADVANCED 12CH 12 Channls MODE BASIS 05CH 5 Channls NORMAL 08CH 8 Channls Dimmer 00 100 Dimmer Red 00 100 Green 895100 ech color Static color Blue 00 100 White 00 100 zoom 00 100 zoom Strobe SP 0 20 0 20Hz Select strobe frequency Aute Auto 1 8 Auto program Custom Custom program Tempreture ON OFF Temperature display on off Color Calib ON OFF Color calibration mode on off Fast Fast dimming with unrestricted speed Dimmer Speed PERSONALITY Smooth Smooth dimming with restricted speed ON Turn on the Wireless W DMX OFF Turn off the Wireless RESET Reset the Wireless SCENE 0 255 Scene R 0 100 red G 0 100 green COLOR B 0 100 blue w 0 100 white Scene Editor S 0 100 0 20Hz Select strobe frequency Fade F 0 255 step time XXX s Time T 0 255 transition time oflaststepto currentstep XXXs Zoom Z 0 255 Wide narrow Use OFF ON Information RESTORED CPU firmware version Factory RST

Download Pdf Manuals

image

Related Search

Related Contents

XP 25 (5e ”d.) Ð TdM  Note Teller 2 - Programa de Asistencia Tecnológica de Puerto Rico  本商品の取扱説明書について 各部の名称 箱の  Leica LED2000 / LED2500 User Manual  MANUAL DEL USUARIO  

Copyright © All rights reserved.
Failed to retrieve file