Contents

1. HOXAeANSSU lt 3 mo Timer Counter Totalizer Totalizer 1 T pes res posee v end 3 En s n esee n ELA Name Tolz1 Desc Source ragi Action Enable Decimal 1 Period Hour Unit Mar Preset 0 0 LOW Cut 0 0 Event Alarm No Type SetPoint Job1 Job2 Il No 100 0 Log Alarm amp utoAck No Action 2 No 100 0 Log Alarm AutoAck No Action 89 Timer 1 Configuration 33 RealTime Configure 400x240 F 7F RNO Timer Counter Totalizer Timeri i EET emper Type Daily Action Enable Time Hour Minute la 9 T Jobi Reset Totalizer Tolzi Job2 Enable Totalizer_Tolz1 It require to Reset Totalizer at start of totalizing every day to begin recording of new data again Timer2 Configuration 2 RealTime Configure d Ex c N el 2 Timer Counter Totalizer o EG RAO Timerz 1 A a e Type Daily Action Enable Time Hour Minute s mam Jobi Log Report_Tolz1 Jobe Disable Totalizer_Tolz1 When Log Report function is used it memorize Totalizer data at specific time which will be used later during reports archival as daily weekly and monthly basis 90 Timer3 Configuration 3 RealTime Configure Type weekly Action Enable Jobi Enable Timer_Timerl Job2 Enable Timer Timerz Timer4 Configuration 3 RealTime Configure Type weekly Action Enable
2. File Page Zoom a b d K Pl Page 1 of3 amp m oom EM s Save ld this is to save report configuration Format of files is Rave snap shot ndr You may download any ndr viewer from internet Print 3 this is to take print out of selected configuration file Exit this is to exit print viewer ERE dE I e KI Pap I of 4 A m D Zoom IER Md Project Testi Timer Configuration Date Time 05 11 09 09 43 10 Timer Type Time Jobi Jab Action 1 Daily 0 Day Hour Minute 1 Sec DO Latch On DOL 4 Mo Action Enable 2 Dady 0 Day 10 Hour 0 Minute 1 Sec DO Latch Off DOI 4 Mo Action Enable 3 Countdown 0 Day D Hour 0 Minute 1 Sec Mo Action Mo Action Disable 4 Countdown 0 Day Hour 0 Minute 1 Sec Mo Action Mo Action Disable 5 Countdown 0 Day 0 Hour 0 Minute 1 Sec Neo Action Mo Acton Disable 6 Countdown 0 Day 0 Hour 0 Minute 1 Sec Ho Acton No Acton Disable 7 Countdown 0 Day 0 Hour 0 Minute 1 Sec Ho Acton Mo Acton Disable E Countdown 0 Day 0 Hour 0 Minute 1 Sec Ho Acton Mo Acton Disable 9 Countdown 0 Day 0 Hour 0 Minute 1 Sec Ho Action No Action Disable 10 Countdown 0 Day 0 Hour 0 Minute 1 Sec Report Preview File Page Zoom SED 144 KK Page i of4 A my B Zoom 1200 R Zoom In Project Test1 Tag Configur ation Date Time 05 11 09 10 04 57 NO Bank Node IP Tag Type EngHi Unit Speed Alarm1 Alarm2 Alarm3 Alarm4 Alarm5 Tag Name Use Gateway Device Type Data Type EngLo Decimal Method SP1 SP2 SP3 S
3. 40121 1 Baud Fate 40122 D Parity 40123 D Stop Bit E 40124 U Reply Delay bd 17 am Stop Description of Modbus Register Baud Rate Enter one of the following values then switch on 54470 to enable 2400 4500 3600 13200 38400 5600 11520 Move Mouse pointer over Value for Description Configuration For ex If you want set baud rate enter the required value in the register 40121 and then press enter in the PC keyboard Set all the parameters once and then switch off the power supply to the IO Module Now switch on the Dip switch 10 on the module to make above settings effective After power on the IO Module will have new Communication settings Please note that at this point of time IO module may not communicate with PC because you may have different settings at RS232 RS485 converter and also COM port settings in the PC Testing the lO Module For ex If you want to test lIO 16DO module It contains total 16 digital outputs You can connect IO module with PC as explained above via RS232 RS485 converter You can force digital output from low to high and check its status at the IO module and also you can observe LED status on the IO Module itself 0 Do not open lO Studio and Real time viewer at same time in your PC First complete IO module configuration using IO studio software close IO studio then open Real time viewer 4 Configuration 4 1 Tools in DAS software 4 1 1 Tool Bar
4. 8 Configuration data New project or close existing project e Open existing project Select page Choice E Measured data or Historical viewer Arrange all Show default screen layout mix digital values bar graph trends Alarm page Display Events Alarms list 124 Display Digital Values Er Display Trend 5 Display all channel Digital la Save Option A Delete this project a Print Bank setting b Channel configuration Channel Display configuration 4 Tools Counter Timers Totalizers configuration Customized Comments for Alarms mE Project Auto Configure Close and return to main program 4 1 2 Menu Bar FilelF View Vv Page P Window W Language L HelpiH En SISI SS View v Page P Wi 3 New B Open Close Recent Create DDE link in Excel i3 Exit RUSUDE Page P Window W La Configuration data Ctrl Alt C E Measured data Ctr E Altti M joy M Language L Window UA FE Arrange all 88 All channel digital AE A Help H Chinese Simplified Chineset Traditional Czech English French German Italian Japanese Korean Palish Portuguese Russian Spanish Thai 4 2 Bank settings 4 2 1 RS232 bank setting 20 Open Real time viewer from Data acquisition studio software Start Programs Data acquisition studio Real Time viewer RealTime Configure Sli h Se M ax 2 y E E Create a new project
5. Guest Properties General Member Of Profile Ls Guest Full name Description Built in account for quest access to the computer d User must change password at next logon v User cannot change password Password never expires Chacon tiet Do not select this Accaunt iz locked aut Then guest will be enabled as shown attached L Computer Management E lel 1 BI E iml File Action View Window Help S x qoc Ele E Computer MEE Local i System Tools El Event Viewer Shared Folders B Local Users and Groups a Users Groups EH Performance Logs and Alerts Device Manager de Storage a Removable Storage z Disk Defragmenter Disk Management Ta Services and Applications Description Built in account For administering tr Built in account For quest access to Remote Desktop Help Assi Account For Providing Remote Assis CN Microsoft Corporation This is a vendor s account For Ehe F enabled properly Now in second computer PC2 check if RealTime folder is opening or not Click on My Network Places L N V Nebwar E Plates 103 Now click on View work group computers e s Infor File Edit View Favorites Tools C9 pack M a jos Address Py Infor Network Tasks 2 Add a network place a View network connections Setup a home or small office network Y Set up a wireless network For a home or small office ey V
6. TES RealTime Configure Click on NO 21 Auto confisuration Device Type 1 0 Card Bank m Protocol Madbus TCP jw Auto update IP address Example 192 168 0111 g Please kev in IP here and then press button ta IP List add it to the IF list E Please select one IP Form IP List and then press button bo remove it l Use Gateway Device Made address x Cancel Click on Cancel Set Bank settings properly first and save it RealTime Configure lanxe Aasaa je Ox e SNES0e 23 80 Bank 1 Protocol Modbus RS232 Y Total 4 banks available for configuration R5232 Com Port com y Baud Rate Parity No Data Bits fe y Stop Bits vw Default 22 Total 4 banks available for configuration and they are for accepting incoming connections from various ports For ex Bank1 Set as Modbus RS232 Now you can receive data to DAS software from any of above ports if they are available After completing Bank settings click on icon a Save and then click on icon To let the new Bank setting take effect system will save them then restart Continue Y N Yes No Click on Yes now DAS will be closed 4 2 2 Ethernet Bank setting RealTime Configure OX NANSG tt gt 3 89 Bank2 Protocol Modbus TCP Ethernet Port 502 Select Modbus_T
7. AVI 1 1 Mo 1 UO Card All List l LO Card 1 AIV2 1 1 Mo 1 LO Card AI Float AVS 1 1 NG 1 I O Card ATI Float AIv4 1 1 NG 1 IO Card ATI Float AVS 1 1 Ma 1 IO Card AI Float Ave 1 1 NG 1 IO Card AI Float Av 1 1 NG 1 IO Card AI Float AIva 1 1 Ma 1 IO Card AI Float 4 4 2 Add new IO module by Ethernet Make sure that IO module is connected to PC via PC E converter Ex Module ID 5 IP address of PC E is 192 168 0 112 Make sure that Bank setting is made properly for Modbus_TCP say at Bank2 2 Use Ping instruction at Dos prompt and make sure that PC E is working fine Command Prompt Microsoft Windows KP Version 5 1 2688 GC Copyright 1985 2661 Microsoft Corp CisDocuments and Settings user gt ping 192 168 868 112 Pinging 192 168 608 112 with 32 bytes of data Reply from 192 168 808 112 bytes 32 timetims TTL 64 Reply from 192 168 0 112 bytes 32 time lt ims TTL 64 Reply from 192 168 868 112 bytes 32 time ims TTL 64 Reply from 192 168 808 112 bytes 32 timetims TTL 64 Ping statistics for 192 168 868 112 Packets Sent 4 Received 4 Lost Y Hz loss gt Approximate round trip times in milli seconds Minimum ms Maximum ims Average Bms Use lO studio software and make sure that IO module is working fine and you are able to see registers of IO module in PC lOStudio BrainChild File About Module ID 5 Start Setup Comms Port Comm Fort TEPP Poll Rate 5 A Tums IF Addres
8. For Digital Input O indicates bit is low 1 indicates bit is high For Digital output Empty indicates no digital output 1 indicates output is available Microsoft Excel DDE_Test3 Ex File Edit View Insert Format Tools Data Window Help 12 BF U E Sal fe RealTimeViewerlTagsService Tag 5 Ho data available at these channels check wiring to the 10 module a p Sh Sh uu wt wr ui ut oc TD 6 Historical Viewer When Real time viewer is running in PC data will be saved in hard disk This data can be archived using measured data with in Real time viewer Click on measured data icon or alternatively in menu click on View then measured data as shown to open historical viewer for data stored using Real time viewer File F Edit E View Y Disply D Page P Search S Help H ae ie h S Sid t e 9 G E 2oomSize zij Baa 1 Scale MARO 2500 0 12 4 l d y 12 51 40 Hs 1 Px 40 13 06 40 05 11 09 05 11 09 3 05 11 09 05 SA C 09 05 11 09 Y Tagl Rearmost v Tag2 1 v Tag3 Y Tag4 v Tags Y Tag i v Tag Y Tags Seek by Legend Seek by Event Alarm Seek by Remark Trend Scale List Pagel Zoom Rate 35ec Dot Index Time 05 11 09 13 16 28 6 1 Tools 6 1 1 Tool Bar 76 To open new project e To open existing project file Print E Display trend cd E t p 9 M m A E Display Even
9. 10 IO Module Set address say 1 for the IO Module using DIP switches on the Module itself Connect 24V DC Power supply to the IO module and make sure that Dip switch10 is OFF to allow communication of IO Module with PC on Default communication settings If you are using RS232 RS485 converter like SNA10A from Brainchild make sure that you have selected all the communication settings properly as follows BAUD RATE 9600 DATA BITS 8 PARITY NONE STOP BITS 1 Communications Port COM1 Properties General Port Settings Driver Details Resources Bits per second E Data bits E S Parity None we Stop bits 1 Flow control Mane Restore Defaults In the PC select above settings at the COM port Right click on My computer Properties Hardware Device Manager COM ports Open IO studio software ey Set Program Access and Defaults Programs IOSEudio ei RealTime viewer L TE FTA Documents K L5 Uninstall Settings K d Search K 2 Help and Support EST Run 10 Studio BrainChild Module ID H Stop Setup Comme Port L amm Port Comm 7 Baud Rate S600 Poll Rate 5 2 ims Select If every thing is proper IO Studio will read the IO Module and show the status of the IO registers If there is a problem please check the following Dip switch settings in IO module Communication cable RS485 RS232 converter communication settings COM port number in PC and
10. 4 10 4 Auto Page In Real time viewer click on Icon Configuration data icon 8 Click on E icon to configure options then select Auto Page tab Share Email Communication Subo page e Interval 15 Sec This function is to rotate pages at set time interval Action Enable Disable options are available Interval This is time interval and max 60 sec is possible If this option is enabled and time is set then display pages in Real Time Viewer will be rotated cyclically as per set time 4 11 Print Configuration It is possible to print channel configuration Display configuration Tools Timers Counter and Totalizers configuration and comments setup Select the required and then click on Print icon EN 56 RealTime Configure Data Typ Ee o 2 Yes 2 1192 168 0 112 1 0 Card Bit ool i I O Card_1 DIZ 1 2 Yes 2 192 168 0 112 1 0 Card 5 Bit Baal 2 I O Card 4 DI3 1 2 Yes 2i 192 168 0 112 1 0 Card DI Bit Baal 3 I O Card 5 DI4 1 2 Yes 2 1192 168 0 112 1 0 Card DI Bit Bool d I O Card 7 DIS 1 2 Yes 2 192 168 0 112 1 0 Card DI Bit Bool 5 Math Operatio DI6_1 2 Yes 2 1 192 168 0 112 1 0 Card DI Bit Bool For Counters and Totalizers maximum 4 channels can be printed at one command Select the starting counter number say 1 then you can print configuration of Counter 1 to Counter4 If you select Counter 3 then you can print configuration of Counter 3 to Counter 7 KR 37 Report Preview
11. Time Day Hour Minute Friday 9 10 Jobi Disable Timer Timer Jobe Disable Timer Timerz Now you can view various reports as follows 91 Display measured values from historical data of C File F Edit E DisplvtD1 HelptH de E Display measured values from historical data of C Data Acquisition StudiolRealTimeWemo1 prj File F Edit E Disply D Help H 22 EE List lt 05 15 09 gt No Type Name Value Time List It lists all the Reports logged with in a day For ex three shifts in same day Daily Select Daily to list log report for total day Use Pe 8 ESA soft buttons to navigate reports of other days Weekly Select Weekly to list log report for current week Sunday to Saturday Use EN gt soft buttons to navigate to earlier and next week Monthly Select Monthly to list log report for current month Use EJ amp soft buttons to navigate to earlier and next months For ex 11 may 2009 Monday total feed rate is 1000 M 12 may 2009 Monday total feed rate is 2000 M 13 may 2009 Monday total feed rate is 3000 M 14 may 2009 Monday total feed rate is 4000 M 15 may 2009 Monday total feed rate is 5000 IM For the weekly report from May10 to May16 it shows 15000 M Ex First week total is 10000 M second week total is 15000 Me third week total is 10000 M and fourth week total is 12000 M then in the monthly report it will show a total of
12. 4 Add A Tag Ses e Auto update Device Type uo Card Bank z Tag Name fauto O Card o a Use Gateway Device Mode address 1 IP address uf OK X Cancel Protocol Device type Select Math operation 38 Modify Tag Data Device Type Bank E c Tag Name Math Log Type LogSpeed 1 Sec lt Trigger by Time lt Data Byte Type S lt NN LogMethad Instant Tolerance Range Low 3276 8 Range High 3276 7 Decimal i lt Expression All1_5 AlI2 5 2 Unik Dea c Engineering er Type fInput Register e Scale Transformation Enable dress 1 L Scale High 100 0 Data Type ih Scale Low 10 0 Event Alarm Type SetPoint Jobi Jobe Hysteresis 1 No b No Action lio Action lo o Z No lo o No Action Bm Action feo 3 m i Ne Action no Action o o 4 No n o No Action No Action foo 5 m o No Action No Action lo o x Cancel Except for Expression it is similar to do the setting up for Analog input explained earlier Define the Tag Name Log Speed Log Method Log Speed Trigger type Data type Decimal Unit Scale Low Scale High and Event Click on data entry box it appears Source Operator and a keyboard The Source covers all available Analog inputs Math inputs Counters and Totalizers The Operators are Mathematic functions described below Use Source Operator and keyboard to define the Math equation The Math expression equation can be keyed in maximum
13. 47000 M 92 6 5 4 Value List It is to view data in tabular column 05 12 09 07 59 44 05 12 09 16 20 01 foom Size 100 m5ec Dot 1 5ec Dot 05 15 2 Sec Dok 5 5ec Dot 10 Sec Dot Various Zoom rates are available for selection 100 msec dot 1 sec dot 2 sec dot 5 sec dot 10 sec dot 20 sec dot 30 sec dot 1 min dot 2 min dot 5 min dot 10 min dot 30 min dot 10 min page 30 min page 1 hr page 2 hr page 4 hr page 8 hr page day page week page and month page Search by specific time Search by a specific time Time 3 15 2009 10 05 07 AM x Cancel 93 e Search by a period of time Search by a period of time From 5 15 2009 10 00 88 AM TO 5 15 2009 10 20 55 AM X cancel 4H T tt These are for navigation of pointer in tabular column fast backward backward forward and fast forward 6 6 Page Selection Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj FilefF Edit E view V Displv D Page P Search 5 Help H B muB ENE ENEE MES Xm ERA In Menu click on Page and then select the required page Number of pages available for display depends on configuration of display pages in Real time Maximum 200 display pages are available and maximum 24 pens channels can be configured in each page 94 de RealTime Configure HOxS H eH MO AAA A A V Tice CP 1 2 O PEO e E
14. If Digital Output cards like IO 8DIO IO 4RO 10 16DO is available in network and then you will be able to switch on digital outputs based on events Can include customized mimics into DAS software No it is not possible Can take print out of trends digital values etc from DAS software Yes it is possible Can write a formula for computation 108 19 20 21 22 23 24 Yes you can use Math channels and write formula Do you have internal timers counters Totalizers etc in DAS software There are 50 timers 50 counters and 50 Totalizers in DAS software want to control the pump based on Real time clock Is it possible in DAS Yes you can use Timer and select type as Daily and then configure start and stop time Can configure Alarms in DAS software Yes it is possible How many Tags supported in DAS software Maximum 1024 including external and internal memory What is Tag It is a channel Ex Al AO DI DO Math etc Can log report of counter values in digital IO module Yes you can use IO 16Dl and it support till 1 KHz You can display counter values of IO 16DI module in DAS software in future 109 BrainChild Brainchild Electronic Co Ltd No 209 Chung Yang Road Nan Kang Dist Taipei Taiwan R O C Tel 886 2 27861299 Fax 886 2 27861395 E mail sales brainchild com tw Website http www brainchild com tw 110
15. Output Status jme 7 14 Module Type 103 Software Version 1 Modbus Value Label Address 20001 SES Tae Meenas Description of Modbus Register 30002 Current Input 1 30003 0 Current Input 2 U m Current Input 1 30004 U Current Input 2 Range 0 4095 12 bits 30005 0 Current Input 4 30006 D Current Input 5 30007 0 Current Input 6 30008 D Current Input 7 30009 0 Current Input 8 30010 21645 Input Status 30100 1 DIF Switch 1012 1 Baud Rate 40122 0 Parit 40123 0 Stop Bit 40124 0 Reply Delay Move Mouse pointer over Value for Description 10 681 Module Type 104 Software Wersion 1 Modbus Value Label Address 20007 360 Tupe 5w Version Description of Modbus Register 30002 Analog Input 1 30003 O Analog Input 2 0 10 Voltage Input 1 0004 U Analog Input 3 Range 0 4095 12 bits 30005 D Analog Input 4 30006 0 Analog Input 5 30007 D amp nalog Input E 30008 D Analog Input 7 30003 D Analog Input 8 30010 21845 Input Status 30100 1 DIF Switch 40121 1 Baud Rate 40122 O Parit 40123 0 Stop Bit 407 24 U Reply Delay Move Mouse painter over value for Description 15 10 81 Module Type 105 Software Version 1 Modbus Address Value Label 30001 361 Type 5 Version S 3000 166 Thermacouple Input 1 30003 JE FED Thermocouple Input 2 30004 JE FED Thermocouple Input 3 30005 32 60 Thermocouple Input 4 3000
16. S Event Alarm List Event value Content 1 Login System 05 08 09 15 56 44 v1 all EE alarm Normal Event Cleared It displays the Ack acknowledgement Type Source Active time Clear time and Value of events or alarms Use scroll bar to move downward or upward Press Ack button to acknowledge the alarm Events do not need to be acknowledged On the Event Alarm List three different colors indicate the status of the alarm ES alarm Red Presently in alarm status Normal Green The cause of alarm status was temporary and has now returned To normal Event Clesred Grey A temporary alarm in green status after having been Acknowledged and then becomes grey Active Time is the time that alarm status becomes active Clear Time is the time when two conditions are met Firstly alarm status is cleared and becomes normal and secondly the user has acknowledged it If any alarm occurs the red buzzer icon on the top right starts to flash After the cause of alarm is no longer met and the alarm is acknowledged then the red buzzer icon disappears When Clear Time shows Terminated this indicates that turning off the power has terminated the alarm 5 1 3 Display Digital Values Display real time measured value from C Data Acquisition 5 File F View PagetF WindowlW Language L HelprH 12 gBemm EEG x Click o
17. Share name RealTime Allow network users to change my Files Learn more about sharing and security y Windows Firewall is configured to allow this folder to be shared with other computers on the network View pour Windows Firewall settings If above options already selected deselect them first Then click on Apply Now select the above options again and click on Apply Then check if Real Time folder is shared or not If it is shared properly it shows with hand symbol as shown below Please refresh the page and check again Nor C GK RealTime Now in First computer PC1 do the following Right click on My computer at desktop 102 L Computer Management OA El Fie Action View Window Help SEID Mame 1 FullName i Administrator Computer Management Local E ills System Tools EH ES Event Viewer Shared Folders E i Local Users and Groups 4 Users Groups El Performance Logs and Alerts de Device Manager n Storage fF gee Removable Storage Disk Defragmenter Disk Management E Ha Services and Applications Description Built in account For administering EF Built in account For quest access to Remote Desktop Help ssi Account for Providing Remote Assis CM Microsofk Corporation This is a vendor s account For the F Make sure that Guest is Enabled No X sign here Select Guest mouse right click click on Properties
18. Software Version 1 Modbus Value Label Address 1000 BRE Digital Input 1 a 10002 EUM Digital Input 2 10003 E Digital Input 3 10004 BERN Digital Input 4 17 EE Digital Output 1 js gt Digital Output 2 30001 6s 7 Type S Version 30002 2 D Input Status 40003 1 Output Status 30004 Jrg AID Input 1 30005 Jar 68 a A ATO Input 2 30006 5 O l maloo Input 1 30007 D Analog Input 2 40008 U Analog Output 1 40009 3 D Counter 1 40011 1 D Counter E 40013 3 D Counter 3 40015 U Counter d 300391 U Calibrate Haw Data 400392 U Calibrate Channel Description of Modbus Register Status of Digital Output 1 Hed 0 OFF Green 1 ON Double Click to change Move Mouse pointer over Value for Description 10 Studio BrainChild File About Module ID 10 160 Module Type 100 Software Version 1 Modbus Value Label Address 40044 U Counter Capture 5 al 40046 U Counter Capture 6 40046 U Counter Capture 40050 U Counter Capture 8 40052 U Counter Capture 3 40054 U Counter Capture 10 40056 E nic Counter Capture 11 40056 8 Oc Counter Capture 12 40060 0 D Counter Capture 13 40062 O Counter Capture 14 40064 oc Counter Capture 15 40066 D Counter Capture 15 307 00 ol 1 DIF Switch 40101 1 1 Counter Made 40702 2 D Input Filter 40103 3 D Counter Zero
19. 32 SCADA There is no need to configure any thing at RSLinx Procedure for configuration 1 Open SCADA project 2 System Node Select DDE server as data source 3 Name DAS No gaps 4 Application RealTime Viewer 74 5 Topic Tag Service 6 Check enable in the box This node should be selected 7 Now open the data base 8 Create analog tag with all the details similar to the tag at the DAS 9 Select DAS at the NODE 10 Write the tag address For ex analog input 1 Al1 should be written as Tag Please check up excel file for the tag number corresponding to the tag name defined in the DAS configuration Please note that underscore is required before the tag number other wise data will not be exchanged 11 Now open the tag monitor and configure for the above tag for checking of DDE with the tag If DDE is configured properly then tag value should appear correctly at the tag monitor with state as VALID If any error message is available then you have to repeat from step 1 Please note that before checking tag monitor Real time viewer in PC should be in running condition 0 Using DDE in Excel it is possible to read status of Math channels Analog Inputs Analog Outputs Digital Inputs Digital Outputs Temperature from RTD and Thermocouple type of IO cards Counter values etc 0 In Excel for Analog input RTD TC IO module at value if it show Error it means no data available in specific channel
20. Card AI Float AIIG 1 2 Yes 5 192 168 0 112 1 0 Card AI Float AIT 1 Yes 5 192 1568 0 112 1 0 Card AI Float Alla 1 2 Yes 5 192 168 0 112 1 0 Card AT Float 4 5 Channel Configuration Add IO module to the data base as explained in previous section In Real time viewer click on Icon Configuration data icon E RealTime Confisure Data a Tepe All List 5 1 jo Card 1 AII2 1 2 Yes 5 211 72 166 deg Card Float AII3 1 2 Yes 51211 72 166 1 0 Card s Float AII4 1 2 Yes 51211 72 166 1 0 Card AI Float AIIS 1 2 Yes 51211 72 166 1 0 Card AI Float AIS 1 2 Yes 51211 72 166 1 0 Card AI Float AIF 1 2 Yes 51211 72 166 1 0 Card AI Float AIS 1 2 Yes 51211 72 166 1 0 Card AI Float Select the required IO card in Device Type and select the Required Tag Name Then double click on the selected Tag name it will prompt the following screen 30 Modify Tag Data zl Device Type Bank Tag Name fami Protocol Modbus_TCP Use Gateway Device Node address IP address Log Type LogSpeed fi Sec v Trigger by Time Data Byte Type 4 Byte X LogMethod Instant v Range Low 14 00 Range High 20 00 Decimal 2 v Gain fi Offset 0 0 Unit f Sensor Type Current mA Engineering Scale High 100 00 Scale Low 0 00 Event Alarm Type SetPoint Job1 Job2 Hysteresis 1 No Y No Action No Action 2 No v No Action No Action 3 No v No Action No Actio
21. DIP Switch Switch 40101 0 Output watchdog Timer Description of Modbus Register 13 10 40 Module Type 113 Software Version 1 Modbus Value Label Address ii Relay Output 1 A G Relay Output 2 3 EQUI Relay Dutput 3 Status of Relay Output 2 4 A Relay Output 4 A B ed IU OFF 30001 369 Type Sw Version Green 1 ON 40002 3 Output Status 30100 1 DIP G wich Double Click to change 40101 U Output Watchdog Timer 40102 U Modbus Masher Timeout 40703 3 D Modbus Master Rate 40121 1 1 Baud Rate 401 22 U Parity 40123 D Stop Bit 40124 U Reply Delay Description of Modbus Register Move Mouse pointer over value for Description 0 00 Module Type 102 Software Version 1 Modbus Value Label Address 10001 M Digital Input 1 A Description of Modbus Register 10002 RERUM Digital Input 2 e 10003 BEER Diaital Input 3 Status of Digital Output 4 10004 SH Digital Input 4 _ Hed 0 0FF 10005 NN igita Input 5 Green 1 ON 10006 MN Digital Input 6 10007 Digital Input 7 Double Click to change 10008 RE Digital Input 8 17 EE Digital Output 1 15 NI Dijital Output 2 15 EI Digital Output 3 Digital Output 4 MIA Dijital Output 5 1 Digital Output 6 Digital Output Digital Output 8 san sg Types Version TEE Move Mouse pointer over Value 3000 ECETIA for Description 40003 15
22. Real time viewer click on Icon Configuration data icon E RealTime Confisure x 8 RI oO 7 Add Mo Device Tvpe All List l UO Card 1 Alle 1 Z Yes E elie 166 TS Card Float AITS_1 Z Yes 5 211 72 166 1 0 Card is Float AII4 1 Z Yes 5 211 72 166 1 0 Card Al Float AITS_1 Z Yes 5 211 72 166 1 0 Card AI Float AIIG 1 Z Yes 5 211 72 166 1 0 Card AI Float AID 1 Z Yes 5 211 72 166 1 0 Card AI Float Alla 1 Z Yes 5 211 72 166 1 0 Card AI Float Select the required IO card in Device Type and select the Required Tag Name Then double click on the selected Tag name it will prompt the following screen 35 Modify Tag Data Tio Tag Name A111_1 Protocol Modbus_ TCP 4 Use Gateway Device Node address IP address 211 72 166 119 Device Type Io Card Log Type Enable Logspeed 1 Sec Trigger by Time Data Byte Type 4 Byte LogMethad Instant Tolerance Range Low 4 00 Range High 20 00 Decimal 12 Gain p Offset o o Unit ots Sensor Type Current m Engineering Register Type Panl Pater E Scale High 100 00 ister Address Scale Low 0 00 Event Alarm Type SetPoint Jobi Jobe Hysteresis 1 No o 06 ho Action st E jo 00 Mo Action Mo Action In on No Action tio E Mo Action H No Action 1 In na X ceca For Analog inputs five events are available for each channel Maximum two jobs can be configure
23. Testi Comment Configuration Date Time 05 11 C No Content 1 2 5 4 5 6 7 8 9 Tank TK101 Level High Message2 Message3 Message4 Message5 Message6 Message Messages Message9 10 Message 10 11 Messagel 1 12 Message12 13 Message13 14 Message14 15 Message15 16 Message16 17 Message17 E 18 Message18 19 Message19 20 Message20 21 Message21 22 Message22 23 Message23 24 Message24 25 Message25 26 Message26 24 Message27 28 Message28 E A Iw 4 12 Backup 4 12 1 Project and Data backup By default project configuration and data files will be stored at the path C Data Acquisition Studio RealTime XxXxX Where XXX is project name 58 If you need to store data in another drive then it has to be selected during installation of data acquisition software Choose Destination Location estination Folder Data Acquistion Studio hoose Folder Ey Data Acquisition Studio CG Documents and Settings Ey KAV Pa Observer x Cancel For ex Name of Project BottlingPlant Then when you create a new project the following files will be created 2 RealTime File Edit View Favorites Tools Help o Back d Search Key Folders Address e C Data Acquisition Studio RealTime Folders S E Desktop ES a My Documents E X My Computer RealTimeProduct LJ DOR pant Configuration Settings 1 KB ES q 314 Floppy 4 E Ss Local Disk C M B gt esal i Bottling plant C3 Data A
24. check if Real time folder at C Data Acquisition Studio is shared or not 100 E Data Acquisition Studio File Edit View Favorites Tools Folders g Desktop ES My Documents E A My Computer q 316 Floppy 45 S Local Disk C C3 Data Acquisition Studio BC Common Historical C Historicallanguage RealTimelanguage RealTime If the RealTime folder is shared properly it shows as above If not Refresh once and check again Irrespective of successful share setting from DAS software we suggest to perform share setting again manually and procedure is as follows Ei Desktop ES My Documents ls 3 My Computer ES q 31 Floppy A e Local Disk C E Data Acquisition Studio Te BC Common C Historical Historicallanguage 2 ORs E g Collapse E Explore ES C L Open G Search Ela T E TIE and Security Select Real time right click then click on Sharing and Security 101 Real lime Properties General Sharing Customize Local sharing and security T Tp share this folder with other users of this computer B only drag it Lo the Shared Documents folder To make this folder and its subfolders private so that only vau have access select the following check box Network sharing and security d To share this folder with both network users and other eh users of this computer select the first check box below and type a share name Share this folder on the network
25. click on Totalizer tab 47 Maximum 50 Totalizers available for configuration 32 RealTime Configure 40x2 anasu gt 3 RO Timer Counter Totalizer Totalizer1 A A ed En sn eg d e d d e L LET Name Tolz1 Desc Source AT 5 Action Disable Decimal n Period Sec Unit Preset 0 0 Low Cut 0 0 Event Alarm No Type SetPoint Job1 Job2 1 no 100 0 Log Alarm AutoAck No Action 2 No 100 0 Log Alarm amp utoAck No Action Name Defines the name of the totalizer Desc Defines the description for a specific totalizer on the display Source Select a specific analog input or Math input to be used for totalizing Action Disables or enables the totalizer Decimal Defines the decimal point for the totalizer Period Selects second minute or hour used for the totalizer Unit Defines the unit of totalizing Preset Defines the preset value for the totalizer The totalizer starts from a preset value Low Cut f Source channel has below this setting then value is skipped from Totalizing Event Defines the type set point Job1 or Job2 Type Select one of three options None Process Hi Process Low Set point Defines the set point of process value to trigger the totalizer Job1 Job2 various jobs as described in 3 6 2 2 jobs for each totalizer 4 7 3 1 Totalizer Example Water flow rate is in M Sec Supervisor want to know about total water discharged and want this information daily weekly and
26. comment only RSIchan DDEInitiate RSLinx DDE_REPORTS write data thru channel This is comment only DDEPoke RSlchan F8 2 L10 Range Reports XLS sheet1 D37 D46 close dde link This is comment only DDETerminate RSIchan End Sub 73 Example 2 DDE link between Allen Bradley SLC 5 03 PLC and Excel Task Read a block of data 5 integers from PLC to excel Name of the Excel file Reports XLS Data Source PLC Starting address N7 30 Target cells in Excel A7 to A11 User RSLinx to configure PLC and DDE link DDE topic name in RSLinx DDE REPORTS Sub Block Read open dde link testsol DDE Topic This is comment only RSIchan DDEInitiate RSLinx DDE REPORTS get data and store in data variable This is comment only data DDERequest RSIchan N7 30 L5 C1 Paste data into selected range This is comment only Range Reports XL S Sheet1 A7 A11 Value data close dde link This is comment only DDETerminate RSIchan End Sub Example 3 DDE between DAS software and SCADA Allen Bradley RSVIEW 32 When the Real time viewer in DAS is working well in PC then the tag data from DAS software will be available in the expression format as follows RealTime Viewer TagService Tag1 Application RealTime Viewer Topic Tag Service Tag name Tag Please observe underscore before the tag number The above tag information can be directly configured in SCADA to enable DDE between DAS software and RSVIEW
27. driver settings Close Real time viewer IO 16D1 Module Type 100 Software Version 1 Modbus Value Label Address 10001 A Digital Input 1 B Description of Modbus Register 10002 RUN Digital Input 2 p 10003 ER Dalal Input 3 Status of Digital Input 1 10004 RE Digital Input 4 s Hed 0 OFF 10005 MN Digital Input 5 Green 1 lt ON 10006 E Digital rout E 10007 RM Digital rout 7 10008 I Digital rout 8 10009 AN Digital Input 3 0010 BRE Dijital Inputt 0 10011 AN Digital inputi 1002 BEI Digital Input 2 10013 BRI Digital Input 3 10014 BU Digital Input 4 10075 N Digital Input 5 10076 EE Digital Input 6 20007 356 Typer Sw mee Move Mouse pointer over Value 30002 Ales p ai 40003 3 D Counter 1 40005 0 Counter 2 10 1600 Module Type 101 Software Version 1 Modbus Value Label Address E Digital Output 1 gt i Digital Output 2 EE Digital Output 3 Status of Digital Output 8 4 EE Dia Output 4 Red 0 lt DFF RY Digital Output E Green 1 ON c Digital Output E 7 Dicital Output 7 Double Click to change S o Digital Output 8 9 25 Digital Output 9 1o EE Digital Output U 11 NEN Digital Outputl 1 iii Digital Output 2 13 EN Digital Output 3 T Ei Digital utpurT4 15 A Digital Outputi5 EN Digital Outputl 0007 IT pper SW Version Move BUE E Value 40002 5 Date Stas Status 30100 0 1
28. totalizer number in the jobs after selecting Preset Totalizer Reset Totalz Reset totalizer into zero and then select Target from Tolz 1 to Tolz 50 It requires configuring totalizer and enabling it to appear totalizer number in the jobs after selecting Preset Totalizer Enable Totalz Start the totalizer and then select Target from Tolz 1 to Tolz 50 It requires configuring totalizer and enabling it to appear totalizer number in the jobs after selecting Preset Totalizer Disable Totalz Stop the totalizer and then select Target from Tolz 1 to Tolz 50 It requires configuring totalizer and enabling it to appear totalizer number in the jobs after selecting Preset Totalizer Preset Counter Start the Counter with a preset value and then select Target from Conti to Cont50 It requires configuring Counter via tools to appear counter number after selection of Preset counter in the jobs Reset Counter Resets the counter into zero and then select Target from Cont1 to Cont50 Inc Counter Increase the counter and then select Target from Cont1 to Cont50 Dec Counter Decrease the counter and then select Target from Cont1 to Cont50 Log Report Make the report for Counter and Totalizer Reset MinMaxAve In Report function after logging the MinMaxAve data of Al and Math channels for one day for example then reset historical data in order to logging new data for the next day Log Message Log customized comments for alarm as messages on an event
29. using the following equation RH Ea Ed 100 The units of relative humidity are in percent Here is an example of the using the equations Assume that your dry bulb temperature Td 40 C and Wet bulb temperature Tw 30 C Ew 0 61078 EXP 17 269 Tw Tw 237 3 Td Tw Ew 0 61078 EXP 17 269 30 30 237 3 40 30 Ew 42 4262 milli bars Ed 0 61078 EXP 17 269 Td Td 237 3 Td Tw Ed 0 61078 EXP 17 269 40 40 237 3 40 30 Ed 73 7416 milli bars Ea Ew 0 63 Td Tw Ea 42 4262 0 63 40 30 Ea 36 1262 milli bars RH Ea Ed 100 RH 36 1262 73 7416 100 RH 48 99 End of Theory DAS support Virtual Math channels 5 Math channels are required to calculate one RH Td AI1 analog input for dry bulb temperature PT100 41 Tw Al2 analog input for wet bulb temperature PT100 Math1 EXP 17 269 AI1 AI1 237 3 Math2 Ed1 0 61078 Math1 Al1 Al2 Math3 EXP 17 269 AI2 Al2 237 3 Math4 Ew1 0 61078 Math3 Al1 Al2 Ea Ew 0 63 Td Tw Math5 RH1 Math4 0 63 AI 1 AI2 Math2 100 Mame Mathi Expression EXP 17 269 AT1 AI14 237 3 Name Math Expression 0 61078 Math1 AI1 Al Name Math3 Expression EXP 17 269 AI AI2 237 3 Name Math4 Expression 0 61078 Math3 AT1 AI2 Name Maths Expression Math4 0 63 AT1 AT2 Math2 100 Now in Math5 you will get Relative humidity in 9o Five events are supported for every Ma
30. 36 characters Edit math expression Input IAI SAR IG Source Operator Counter2g Counter3 Counter3 Counter32 X Cancel 39 Math Expressions SIN x COS x EXP x SQRT x LN x LOG x ABS x POW x y ROUND x HI x y LO x y INV x TG x CTG x ASIN x ACOS x ATG x x y Addition Subtraction Multiplication Division sin x cos x e Square root of x loge x log 10 x Absolute of x y X The closest integral number to x The bigger value between x and y The smaller value between x and y 1 x tan x 1 tan x Sin 1 x Cos 1 x Tan 1 x Remainder of x y 40 4 5 7 1 Math Example Relative Humidity Math application How to Calculate Relative Humidity Theory Requirement Two Analog Inputs Type RTD Al1 To measure dry bulb temperature Al2 To measure wet bulb temperature First calculate the saturation vapor pressure E for both the dry bulb Td and wet bulb Tw temperatures using the following equations Ew 0 61078 EXP 17 269 Tw Tw 237 3 Td Tw Ed 0 61078 EXP 17 269 Td Td 237 3 Td Tw In the above equations the temperatures units are Celsius and the saturation vapor pressure units are milli bars The function EXP is the exponential and not raising something to an exponent Then calculate actual vapor pressure Ea using the following equation Ea Ew 0 63 Td Tw Relative Humidity is then calculated
31. 3DigitalPage1 P ar BRE Digital Event zz Arrange all EE All channel digital 61 Display real time measured value from C Data Acquisition Studio Reallime emo1 prj File F Yiew Page P Window W Language L Help H amp j mBemrm Nd BE o E o sve WM Event Alarm List Secs mE Ack Type Source Value Content 1200 0 1300 0 1400 0 1600 0 1600 0 1700 0 1 Login System 05 08 09 15 56 44 120 0 120 0 120 0 120 0 120 0 120 0 2000 0 2100 0 2200 0 2300 0 2400 0 2500 0 Digital Page1 2 E x S Trend Page1 16 01 06 05 08 09 Taali Page1 Page1 Sampling Rate 1 Sec Scan Time 6 ms start Th UMDAS Microsoft W ZH Recorder ENU Micr pa VR18 Manual 2 3P p 5 untitled Paint Viewe S BLA 4 07PM 5 1 2 Display Events Click on Event Icon to show events in full page alternatively in Menu click on Window and then click on Event Display real time measured value from C Data Acquisition File F View PagerF WindowiW Language L HelprH Ae Display real time measured value from C File F View V PagelP Bas LanguagelL k Qu i E Es Trend HEE Bar ME Digital a Digital Page1 SR Arrange all BEER Al channel digital Status 62 S Display real time measured value from C Wata Acquisition Studio ReallimeWemo1 prj File F Wie WindowrwWw LanguagelL HelprH Da arpa EIE H E
32. 6 Sd ate Thermocouple Input 5 30007 7 JE FED 91T Thermocouple Input E 30008 Jr BA 9 Thermocouple Input 7 30009 g Je PD 91T Thermocouple Input 8 30070 ATS CJC Temperature 30011 21044 Input Status 3007 6 65415 Calibrate Raw Data ADT 7 U Calibrate Control 301 Da 1 DIP Switch 40101 1 Thermocouple Type 40102 AL Line Frequency 40103 100 CJC Offset 40104 1 Display Units C F 40121 1 1 Baud Rate ioa opan IQ EATD Module Type 109 Software Version 1 Modbus Address 30001 365 IType Sw Version 30002 6500 AID Input 1 30003 42766 AID Input 2 30004 27 66 IRTD Input 3 30005 dar bA IRTD Input 4 30006 2 66 AID Input 5 30007 42766 RID Input E 30008 8 1364 4 Input Status 30076 El 34423 3 Calibrate Haw Data 4001 z D Calibrate Control 30100 T 1 DIF Switch 40701 1 IRTD Type 4002 AU Line Frequency 40103 U Display Units CF Value Label 4121 1 Baud Rate 4r 22 U Parity 40123 U Stop Bit 40124 U Reply Delay Description of Modbus Register Thermocouple Input 1 Range xxx bo yum y Example 101 44 wil be read back as 1014 Move Mouse pointer aver Value for Description Description of Modbus Register ATO Input 1 Range amp xx to yu y Example 107 4 C wil be read back as 1014 Move Mouse pointer over Value for Description 16 10 0 810 Module Type 112
33. 7 Frequently asked questions 1 What is the difference between Data acquisition studio and IO studio software IO Studio software is a tool used for configuration of IO module from PC and it is also used for IO module diagnostics purpose It is not for Real time Data logging and archival Real time viewer is for data logging and archival What is the difference between Observer software Communicator software and DAS software Observer software is used for Brainchild Paperless Recorder Communicator software is used for Brainchild Temperature Controllers DAS software is used for Brainchild IO modules Paperless Recorders and Controllers DAS software is similar to Observer software but with additional features Please check section 1 3 for details information about features available with DAS software Can open IO Studio and Real Time viewer at same time in PC No First open lO studio software for configuration of IO module Close lO studio software and then open Real Time viewer Can open Observer software and DAS software simultaneously in single PC No it is not possible It may conflict some of resources and it may generate some error messages It is not required to run Observer software and Data acquisition software simultaneously in same PC as Data acquisition software also covers paperless Recorders and Controllers shortly along with IO modules In this case it just need to uninstall Observer software and install data acquisi
34. A total of 100 messages available for customer customization Hysteresis To avoid job have been activated too often option available to set for no reaction in 0 1 to 10 of full span Low Scale to High Scale Note Each of the IO modules has different sampling rates For every channel it requires to specify the sampling rate in data acquisition software By default DAS will acquire data from each of the IO module with sampling rate of 1 sec Minimum available sampling rate is 1 sec Available options are 1 2 5 10 30 60 120 sec For ex lf the logging speed is set at 10 second in Instant mode the DAS logs using the last of ten measured data values it acquired in last 10 sec at rate of 1 sample sec For the same speed in Averaging mode the DAS logs using the average of the ten measured data values it acquired at rate of 1 34 sample sec For the same speed in the Maximum or Minimum mode then the DAS logs using the maximum or minimum of the ten measured data values it acquired at rate of 1 sample sec Sampling Logging historical trend Display real time Instant 10S the last of 10 measured data the last of 10 measured data Averaged 10S the average of 10 measured data the last of 10 measured data Maximum 10S the maximum of 10 measured data the last of 10 measured data Minimum 10S the minimum of 10 measured data the last of 10 measured data 4 5 3 Analog inputs Add IO module to the data base as explained in previous section In
35. Ae Apo e 4 pms c mme ft z po poo 5 ass Wwe zo p00 poo 6 COM OCC CNN AN CN ar arl a 5 2 Data dynamic Exchange DDE Dynamic Data Exchange DDE is a standard inter application communication protocol built into Microsoft Windows operating systems and supported by many applications that run under Windows DDE takes data from one application and gives it to another application lt allows Windows programs that support DDE to exchange data between themselves Data from DAS software can be exchanged with Excel on DDE link After completion of all network configuration adding of all Modbus slaves then open Data acquisition studio software from start programs Data acquisition studio Real time viewer Project create DDE link in excel Display real time measured value from C Wata Acqu mim View V Pagef Windowriw LanguagerL Help H 3 Mew gt pen Close Recent 05 11 09 10 14 21 789 Create DDE link in Excel Exit 70 Specify the path and file name as follows Save As AJA Save In E Desktop EE E EX E ray Documents E My Computer My Recent amp JMy Network Places Documents _ een Desktop My Documents Mu Computer m s Places Save as type excel file Pcs Cancel Mu N ehao File name By default the file name will start with DDE and the project name with underscore Save the file name in PC at select
36. C with Minimum 200 MHz processor 128 MB RAM 100 MB free space in the hard disk RS 232 serial port Ethernet Network adopter RJ 45 female Operating system Windows ME Windows XP Windows Vista Windows NT amp Windows 2000 1 3 DAS features 1 3 1 Real Time Viewer v 1024 tags including Al AO DI DO amp Math v 1 to 24 configurable tags display per page maximum 200 display pages v Math channels v 50 Timers 50 Counters and 50 Totalizer s v 100 comments for Alarms v Real time trends Bar graphs Digital value display v Real Time Alarms Y Log Speed 1 2 5 10 30 60 120 Sec Log Methods Instant Average Minimum amp Maximum Log trigger type By time By value change v Alarms by Email Y Display languages English French German Italian Japanese Korean Polish Portuguese Russian Spanish Thai and Czech Chinese Traditional and Chinese Simplified v Connection to IO Modules Paperless Recorder Controllers and any third party devices via Modbus RTU or Modbus TCP protocol v Five different types of Events can be configured for each channel and each event support 2 jobs So total 10 different jobs can be set per each channel Y Event Type available for Trigger H HH L LL Rate of increase Rate of decrease and Error v Jobs Available to link with events Log Alarm Log Event Log Alarm Auto ack send email Sound buzzer DO Latch ON DO Latch OFF DO Process Enable Timer Disable Timer Preset To
37. CP protocol in any freely available Bank Port number should be 502 for Modbus TCP protocol After completing Bank settings click on icon k Save and then click on icon To let the new Bank setting take effect system will save them then restart Continue Y MN Yes No Click on Yes now DAS will be closed 4 3 Create New Project Open DAS again 23 Start Programs Data acquisition studio Real Time viewer Create a new project TE Ox Enter the new name Testi X cance Information There are no tag data in the project Do vou want to configure iE 2044 Protocol Madbus R5232 e Auto update Node address y OF X Cancel Select the Bank properly and enter Address of IO module as shown above Click on OK O Note If you have more than one IO module already connected in RS485 then select Auto Update and then you can enter starting and ending address of IO module in above screen to acquire tag data base of all the IO modules at a time Alternatively other modules can be added individually as explained later 24 RealTime Configure Axa 85 ANG Eu o X Mo Device Type Use Gateway Node IP Device Type ag Type AI All List Alvi 1 1 Mo 1 LO Card 1 IO Card 1 Alvz 1 1 Ma 1 IO Card AIV3 1 1 Mo 1 NO Card AIV4 1 1 Mo 1 I O Card AIVS 1 1 No 1 I O Card AIVO 1 1 Mo 1 IO Card AIV 1 1 No 1 NO Card AIV8 1 1 Mo 1 IO Card Click on icon IS Save lt sh
38. Channel Color Width Low High lt P P Forward 6 5 2 Events Alarm List It is to view list of Events Alarms Display measured values from historical data of C Wata Acquisition Studio ReallimeWemot1 prj FilegF Edit E view BIB Page archt5 HelprH B E c EE Trend view EEE fed Event Alarm List S Report List Mo tack 7 Walue List Active Time Clear Time value Contents 1 L 5 05 08 09 15 47 32 2 Logout System 05 08 09 15 55 18 3 Login System 05 08 09 15 55 18 4 Logout System 05 08 09 15 56 43 5 Login System 05 08 09 15 56 44 6 O Hi amp larm Tagl 05 08 09 15 58 19 Terminated 993 1 O HiHiAlarm Tagl 05 08 09 15 58 19 Terminated 403 1 8 LI LoAlarm Tagl 05 08 09 16 03 21 Terminated 103 8 a O LaLoAlarm Tag 05 08 09 16 03 47 Terminated 19 9 10 Logout System 05 08 09 17 00 40 It shows list of Alarms events as per occurrence of event as per channel configuration 88 Event Alarm Tvpe SetPoint Jobi Jobe Hysteresis 6 5 3 Reports List It is to view list of reports f Trend View Event Alarm List Tail Report List Value List 6 5 3 1 Reports Example A factory operates for 8 hours a day from Monday to Friday and the staff wish to get the total volume of production from daily weekly and monthly reports Start totalizer at 8 00 hrs Stop Totalizer at 17 00 hrs Source of Process value Analog inputl feed rate 1000 M hr Totalizerl configuration 32 RealTime Configure
39. Dot Zoom by 2 Min Doat zoom by 5 Min Dot zoom bv 10 Min Dot Zoom by 30 Min Cot zoom by 10 Min Page zoom by 30 Min Page zoom bv 1 Hour Page Zoom by Z Hour Page Zoom by 4 Hour Page Zoom by amp Hour Page Zoom bv Day Page Zoom by Week Page zoom by MonthPage Horizontally Vertically Bl Black background UU white background Zoom Various options available for selection as shown above Horizontally To view historical trend horizontally in screen Vertically To view historical trend vertically in screen Black background To set black back ground for historical trend White background To set white background for historical trend 79 Disply Dr Event Alarm List E Report List Value List Page To select the page E By Time in ery By Period w By Legend By Event Alarm By Remark Search To search historical data by various options Historical Viewer Help E About 6 2 Export data to Excel Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj FilefF Edit E view V Dispi Page P Search 5 Help Be S BO 8 hd EN EEES jme TIE BA 1 scale af of Impurt CLL AIE E Export Cer alk o Clear iCkrl AlE L de Copy Chr alte Remark Cora l R Import Option M Signature Ctri alt s 80 Export data in Excel Range Select Pens Speed value below will be the dot interva
40. P4 SP5 1 2 2 192 168 0 112 DI i 1 Sec H L No No No DI Yes I O Card Bit Bool 0 Instant 1 0 2 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI2_1 Yes I O Card Bit Bool 0 Instant 3 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI3 1 Yes I O Card Bit Bool 0 Instant 4 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI4_1 Yes I O Card Bit Bool 0 Instant 5 2 2 192 168 0 112 DI 1 1Sec No No No No No DI5 1 Yes I O Card Bit Bool 0 Instant 6 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI6_1 Yes I O Card Bit Bool 0 Instant 7 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI7_1 Yes I O Card Bit Bool 0 Instant 8 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI8 1 Yes I O Card Bit Bool 0 Instant 9 2 2 192 168 0 112 DI 1 158 No No No No No DI9 1 Yes I O Card Bit Bool 0 Instant 10 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI10 1 Yes I O Card Bit Bool 0 Instant ny 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI11 1 Yes I O Card Bit Bool 0 Instant T2 2 2 192 168 0 112 DI 1 1Sec No No No No No DI12 1 Yes I O Card Bit Bool 0 Instant 13 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI13 1 Yes I O Card Bit Bool 0 Instant 14 2 2 192 168 0 112 DI T 1 Sec No No No No No DI14 1 Yes I O Card Bit Bool 0 Instant 15 2 2 192 168 0 112 DI 1 1 Sec No No No No No DI15 1 Yes I O Card Bit Bool 0 Instant 16 2 2 192 168 0 112 DI 1 1 Sec No No No No No v lt gt Report Preview File Page Zoom aR 4 KRN page fl of AASB Zoom E R Project
41. User Manual Data Acquisition Stadia BrainChild UMDASA Rev 1 0 06 2009 TABLE OF CONTENTS le INTRODUC TION D 5 1 1 INTRODUCTION T P 5 1 27 SYSTEM REQUIREMENTS ed ade dl 5 143 DAS FEATURES 2 lei tms 5 13 41 Real IMSS H rr rada 5 1 3 2 FISTONCAl di lp eet E 6 1 3 3 Sample elec Le 7 Z SOFTWARE INSTALLATION P 8 2 DAS SOFTWARE INSTALLATION 2 4 ect ead ce hae aie ici 8 22 DAS SOFTWARE UNINSTALL s rented doo Monnet es EUER 10 3 AOS TUD O ect 10 4 CONFIGURA TO Nara 18 Al JOORSIN DAS SOFTWARE itecto cud taire stnidadd sana oet utn aee rd dao oce ace 18 4 1 1 TOO BO ecce plebi A LIE E Lie 18 4 1 2 Menu BA T ob 20 AZ BANK SETTINGS OP O UA Svante eee E etl fee 20 4 2 1 Roz3Z DANK Sci eric E 20 4 2 2 Etemel Bank SUING iaa oia iO aio ies co dial ries 23 WO CREATE NEW PROJECT sans ibid 23 4 4 ADDING OF NEW IO MODULES INTO NETWORK xxx e e e e ee eee 26 4 4 1 Add new IO module by RS232 RS485 sse 26 4 4 2 Add new IO module by Ethernet occooonccoccccocnccocnccccnonanccnanccnnncnncnonaninnons 2f ASD CHANNEL CONFIGURATION ca a iia 30 4 5 1 EVEN nn 32 4 5 2 doom m cm MEO D 33 2X EC MEM NPU s AoSe tach 35 4 5 4 BIST iie cO a 36 4 95 JAndlog OUMU sio tute ssttostac ohne puesto too tacto head abut also scs testae chaton 37 4 5 6 Digital OUUDEIIS iori cda 37 4 5 7 Qin C ieh Ee EE Hm 38 4 6 DISPLAY CONFIGURATION eee e eee 42 44 TOOLS CONFIGURATION iiair esed tct bp eed EOS ds 44 4 7 1 Mc 44 4 7 2 A O Pene
42. a need to be available M Event file Select path of event files where all the excel files event alarms to be available By default all the above files will be stored at C Data acquisition Studio Real Time Project name Project name_pen csv lf different installation folder given during installation of DAS software then files will be stored in specific path If you wish to store data event excel files in different folder click on e icon and then specify the target folder and click on Save 0 If there is large data after 65535 rows it creates new excel file with name Project name Part X where X is the file number say 1 2 etc 6 3 Remark This is used to mark comment on data after verification For ex supervisor check historical trend and wish to mark a comment say Irregular at specific date time Maximum 40 characters are allowed in each remark Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj FilefF Edit E view V Displv D Page P Search 5 Help H 1 Scale View Displv D Pac Import Chr ealk 1 Ag Export Crealo Clear Ctrl Alt L de Copy Ckri Alt C em Remark Ckri AlE F Import Option In historical viewer there is a pointer which moves around the trend for selecting the data Just use the mouse and left single click on historical trend then you can see pointer as shown attached 82 c L is d L l a md mmm k ee ee ee
43. act as Modbus Master and Acquire data from IO modules acting as Modbus Slaves in RS485 network The serial port of the PC is connected to an RS232 RS485 Converter like SNA10A which in turn is connected to the Network Alternatively Ethernet port of PC is connected to Protocol converter like PC E as shown attached Applications Data Acquisition to PC via Serial Port 16D PC BE Digital Serial Link M Inputs RS232 RS485 120 Ohm Termination Converter ae Request Master i dius laves RS485 Network Hanaapse K 120 Ohm Termination Analog n Digital y Outputs nputs Applications Data Acquisition to PC via Ethernet PC gt EM Digital _ Ethernet 1 Inputs Serial to Ethernet Converter PC E 120 Ohm Termination Modbus gt Request Master or Slaves Response RS485 Network 120 Ohm Termination Digital Outputs 2 Software Installation 2 1 DAS software installation Install DAS software from CD lt installs Real Time viewer and lO studio software automatically IO Studio software is used to configure Modbus based IO modules from Brainchild IO studio required Net frame work and it will be installed during installation of DAS software Insert Hardware lock Key pro in PC at USB port With out hardware lock DAS software will run for one hour in demo mode 27 Data Acquisition Studio setup 40 BEBENEZEZRE Choose Destination Location Ix estination Fold
44. and third party applications running under windows operating systems via DDE Procedure to find the tag number for the tag name to use in DDE applications Create DDE link from Real time viewer Open Excel file Three columns appear in the excel file as Name Unit and Value as shown in the Excel file Name This is tag name actually defined in the channel configuration Unit This is unit for the tag name defined in the channel configuration Value This is the specific cell where process value for the tag will appear in real time To find the DDE format for any tag in channel configuration for a specific tag double click at Value column for the corresponding tag defined at Name For ex For Name Tag1 is at R2C1 double click at cell R2C3 to see DDE format for Tag1 Click on Esc button at the key board to see process value at the cell from displaying DDE format ES Microsoft Excel DDE Demo1 icu File Edit View Insert Format Too MA lcd la RI A ca C21 Y L Name Double click Tago here to see 20 5 Tag DDE format 96 5 8 Tag 96 8 9 Tag amp Press Esc 26 8 10 Tag9 button in 96 8 il Tagio Keypad to go ggg back to view 12 Tagll process value 96 8 3 Tagl2 in real time 0628 1 Tagl6 90 5 If any Error appears in any cell at excel possible reasons is no data available at selected tag Check the channel configuration and make sure value is available If any NAME text appears in the ex
45. cel file it indicates that particular tag is not configured properly Tag name may not available at DAS software 12 Note If Excel file is not opening from the selected path then check the following 1 RAM size in the PC is very less Restart the computer and then create the DDE link once again and open the Excel file Increase virtual memory in the PC Please contact system administrator to check the virtual memory settings at the PC My computer properties advanced performance settings advanced virtual memory DDE with third party applications Once the data is available at Excel at particular cell then data can be exchanged with the third party applications like PLC SCADA and Visual Basic etc If data is to be exchanged with PLC then PLC programmer can write Visual basic macro in Excel from the following link Excel Tools macro For the source code examples PLC programmer may check the PLC manuals for DDE sample macros It is also possible to exchange data from recorder to SCADA applications through DDE Example 1 DDE link between Allen Bradley SLC 5 03 PLC and Excel Task Write a block of data 10 floating points from Excel to PLC Name of the Excel file Reports XLS Data Source D 37 to D 46 data in total 10 cells Target PLC Starting address F8 User RSLinx to configure PLC and DDE link DDE topic name in RSLinx DDE REPORTS Sub Block_Write open dde link testsol DDE Topic This is
46. cquisition Studio NEZ s NZ File 5 BC Common ba m 1 Historicallanguage 5 Bottling plant E C Data O 20090514 C3 20090518 C3 RealTimeLanguage HTS Configuration Files Data Files 59 File Edit View Favorites Tools Help Q sack amp K yo esp Ey pa dens E Data files amp ddress CiData Acquisition Studio RealTimetlBattling plant Data olders Ej Desktop a 20090514 a 20090518 ES E My Documents 3 My Computer 3 OptionConfigure cfg _ RealTimeConfigure cfg Job 3 Floppy A CFG File CFG File E S Local Disk C 1 KB alo E 5 Data Acquisition Studio pea pl pud 4 Tools alue cfg istoricallanguage 31 File HH CFG File 0 RealTime de ica Zr ILER HE IKB 3 5 Bottling plant E C3 Data c 20090514 Data files Configuration C3 20050518 Format of folder files Y Y HHDD 5 RealTimeLanguage Y Year HH Month D Date Take BACKUP of C Data Acquisition Studio RealTime regularly and store in safe place 4 12 2 Restoring Project with Data Install Data acquisition software Copy Realtime folder to C Data Acquisition Studio Open the project from data acquisition software Start Programs RealTime viewer 4 12 3 Sending Project files In case of any problems in configuration if you wish to send project files zip RealTime folder available at C Data Acquisition Studio except data files and send it to us 0 If project is running for few day
47. d for each event 4 5 4 Digital Inputs Modify Tag Data eL W Auto update Device Tvpe IO Cat Bank Tag Mame Protocol Modbus TCP Use Gatemay Device Made address E IP address zh Event Alarm Tvpe SetPoint Jobi Job2 E 1 H Log Alarm Mo Action 2 L Log Alarm No Action x Cancel For Digital inputs two events are available for each channel Maximum two jobs can be configured for each event Ex When DI1 is high Log alarm when DI1 is Low Log alarm 36 4 5 5 Analog Outputs C Modify Tag Data le Auto update Device Type Bank Tag Name Protocol Modbus TCP Use Gateway Device Mode address IP address Log Output Range Low 0 0 Range High 100 0 Decimal n Expression AHL1 AHS Sensor Type 0 20 Currenkim x Cancel Output Select Enable or Disable Range Low Defines the low scale with decimal if necessary For instance output 0 20 mA the Scale Low can be set up with value 0 0 to be correspondent to low range 0 mA Range High Defines the high scale with decimal if necessary For instance input O 20mA the Scale High can be set up with value 100 0 to be correspondent to high range 20mA Expression It is possible to write a formula up to 36 characters If user attempts to write more than 36 characters in formula it prompt an error message indicating strings in expression should be less than 36 characters Mathematic functions are supp
48. d to save memory in PC If data logging is required in set log speed fixed time interval select Trigger as by timer If data logging is required only when there is change in process value then select Trigger as by change This will save memory Tolerance This is enabled if by change is selected at Trigger Type For ex If tolerance is set at 0 5 then if the new process value is more than or less than 0 5 then only the new sample will be logged Data Byte Type Choose 2 or 4 or 8 byte Range Low Range low for specific channel in selected device ex 4 00 mA for IO 8AII module Range High Range high for specific channel in selected device Ex 20 00 mA for lO SAI module Decimal select one of the options 0 1 2 3 or 4 Gain It is a multiplier to correct the sensor error The correct value the process value offset x gain Offset It is offset value to correct the sensor error Unit The engineering unit of input Sensor It displays input type automatically as per the type of IO card selected Scale Low Defines the low scale with decimal if necessary For instance input 0 10 V the Scale Low can be set up with value 0 00 to be correspondent to low range 0 V Scale High Defines the high scale with decimal if necessary For instance input 0 10 V the Scale High can be set up with value 100 00 to be correspondent to high range 10 V 4 5 1 Event The Event is frequently used for Alarm purpose Event can also be used
49. e e E l ees Est alL Mode Enable Page Marks Speed 1 Sec Dat Direction Horizontal Page Background Black Mo Channel Color Width LOW High 1 kea mes 3j E freno Sp 3 z 2 aoe ji IE Ems 4 rags Bred zn siang mon 5 Tags Mimagenta R Afa eo 5 rs s yew Yellow fi Aao feo 7 frag C Gray Ah Afo eoo 8 rage a ckward Forward E Deep Blue Fig Display pages configuration in Real time Note In Mode if Disable is selected then page will be not visible in either Real time viewer or Historical viewer 6 7 Search It is to search data and then take print out of trend if required Data can be searched with following criteria By Time By Period of Time Seek by Tag Name Seek by Event Alarm Seek by Remark l Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj FilefF EditfE view v Displv D Page P BR Help HT gt e E E Bl B a 6E nb La A T de ek i a El Zoom Size E p jamaj El Scale lt T 6 7 1 By Time It is to search data by specifying exact date and time 95 Click on icon for search by specific time alternatively in Menu click on Search and then Select By Time te By Time a By Period w By Legend By Event Alarm By Remark Enter the required date and time of the data to be searched and click on OK then pointer in tre
50. e ee l ee SS d PE l m This is curser point for exact date time selection mur c cde mE I TUE a LE T E mM ec Tm c ce taxon pred allie ery TE r r HM M vag 130553 130688 anga 130907 131012 AR a2 1 08 05 11 09 05 11 09 05 11 09 05 11 09 05 11 05 Us EL 05 11 09 Place the pointer at exact date time required then in menu click on Edit then Remark and now it prompts the following Remark Edit Remark Time 9 11 2002 1 09 09 PM E Contents Irregular Can not more then 40 words x Cancel Click on OK after writing remark asi 130558 13 06 58 13 08 03 13 09 07 13 10 12 Sox 13 12 22 1 1 09 05 11 09 05 11 09 05 11 09 05 11 09 05 11 09 05 11 09 of sesolesewegegeaegeceeoale see O O O O O O O O O A RRE RR RN A RR ER MR ER RR AR RR RN cd Content Irregular Remark Time 05 11 09 13 09 09 Pagel Page Zoom Rate 100 mSec Dot Index Time 05 11 09 13 09 09 83 Later it is possible to search data with respect to above remark by any one of the following way Click on Remark icon 3 In Menu click on Search then select Remark EIE HaelpiH Bv Time a By Period By Legend By Event Alarm By Remark Alternatively near the task bar at bottom area of the screen click on Seek by Remark i Trend Scale L
51. ed path as above to proceed further For example if desk top is selected in the path then excel file should be available in the desk top If the MS Office is not installed in the PC then you cannot open the excel file created as above procedure Please contact your system administrator to install MS office software in the PC Now try to open the file from the desk top created for using DDE application with the recorder through Observer software Microsoft Excel This workbook contains links Ea other data sources IF you update the links Excel will attempt to retrieve the latest data IF vou dont update the links Excel will use Ehe previous information Note that data links can be used to access and share confidential information without your permission and possibly perform other harmful actions Do not update the links iF you do not trust the source of this workbook Click on update to activate DDE between DAS software and Excel application If the DDE is successful then real time data of the channels should be updated in excel file as shown in sample screen DDE expression format to get real time data from the Observer software is as follows Real Time Viewer TagService TagN Where N 1 2 3 Application RealTime Viewer Topic Tag Service 71 Tag name Tag Please observe underscore before the tag number It is possible to exchange data related to Al DI DO Counters and Totalizers between DAS software
52. el as a drawing pen its color width Display Hi and Display Low Channel Selects a specific analog input Al or Mathematics Math or selects Disable if a specific channel is not required Color Selects the color for each pen 43 Width Selects the width of trend 1 thin 2 medium 3 wide Low Defines the low scale for a pen on the display High Defines the high scale for a pen on the display Forward backward button It is to navigate to next earlier 8 sets of pens for display configuration 4 7 Tools Configuration In Real time viewer click on Icon Configuration data icon E 2 RealTime Configure S x2 L Sel Auto Tools Click on 5 icon for Tools configuration 4 7 1 Timers 3 RealTime Configure 0x23 2 4430 Fert KO Timer Counter Totalizer Timer i 2 fa 2 5 5 rese pe pu es e E Sg Type Countdown Action Disable Time Day Hour Minute Sec Job1 No Action Job No Action Maximum 50 timers available for configuration Type Countdown Repeat Countdown Daily Weekly or Monthly Countdown Defines the interval of time e g days hours minutes and seconds Not Real Time clock 44 Repeat Countdown Repeats the previous countdown Daily Weekly or Monthly The timer works in selected interval of Real Time clock Action Disables or enables the timer Job1 Job2 various jobs as described in 3 6 2 2 jobs for each timer 4 7 1 1 Timer Example Switch o
53. er Data Acquisition Studio hoose Folder 73 ALDUS Ey Avis5ys 73 Backup river Selection E c M x Cancel Select Folder x Cancel Program Folder Data Acquisition Studia Congratulation Run DAS as follows Q Set Program Access and Defaults ES Windows Catalog a Windows Update Simatic O Shortcut to Service lt gt Program Updates y Microsoft Update Uninstall de IOStudio X RealTimeViewer aa Data Acquisition Studio fax Programs Ec Documents Settings gt 49 Search d Y Help and Support 4 Run Shut Down sa Windows XP Professional start Cl Recorder_EN 7 wi Sent Items 2 2 DAS software Uninstall Start Programs Data Acquisition studio Uninstall 3 IO STUDIO This is a tool useful for setting configuration of IO module and used for diagnostics purpose This tool will be installed during installation of Data acquisition software and can be opened from Start Programs Data acquisition Studio IO Studio Ex Set communication settings Read IO status in PC Force Outputs to test the Output modules 0 Do not open lO Studio and Real time viewer at same time in your PC First complete IO module configuration using IO studio software close IO studio and then open Real time viewer IO Module etu LE M ann aan as t TII RS485 RS232 Converter
54. for digital output DO Timer Totalizer Counter or Report Type There are various types of H L HH LL R r or Error to be selected for job or Alarm purpose H High limit When the process is over high limit the alarm or job is actuated 32 L Low limit Any the process is lower than low limit the alarm or job is actuated HH High high limit to set up another limit higher than high limit for double warning LL Low low limit to set up another limit lower than low limit for double warning R Increasing rate of change The job or alarm is actuated when the rate of increasing process value is greater than the specified rate time interval For example when the Set point is set to 100 15S if the process is increasing greater than the value 100 in 1 second then job or alarm will be actuated r Decreasing rate of change The job or alarm is actuated when the rate of decreasing process value is greater than the specified rate time interval For example when the Set point is set to 50 25 if the process is decreasing greater than the value 50 in 2 seconds then job or alarm is actuated Error f there is error in channel input then alarm or job is actuated Set point To set up the process value for actuating Job1 and or Job2 Job1 Job2 When an event occurs the task to be performed is called the job A typical example is to trigger sound buzzer in event of high temperature Each pen can accept five events or alarms and each eve
55. ide of the screen as shown above Select the Remark and double click Then pointer in trend will go to data where specific remark is marked earlier 6 8 Print It is to print Trends Events Alarms Reports Process Values etc First it requires to search the historical data as explained in earlier section and then click on Print icon it open Print preview first and then click Print icon again to take print out Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj FilefF Edit E View Displv D Page P Search 5 HelpiH IAEA ENEE LATE EE EN FiletF p Open Cro Print hou Recent k Exit 99 6 9 Share It is possible to share historical data stored in one computer and view this historical data from other computers in the Local area network It is not required to have hardware lock keypro in second computer to view historical data Hardware lock is required only for Real time Viewer First Computer name PC1 Real time viewer Second computer name PC2 To view historical data Project name Bottling plant In first computer open Real time viewer and then open Bottling plant project Click on configuration data icon gt Then click on Option icon S Select share then select share data so that other people can read it option and then click on OK soft button Option Do nok share f Share data so other people can read it x Cancel Now
56. iew workgroup computers Show icons For networked UPnP devices Shows you all the Now select First computer PC1 and double click it to show the following screen File Edit View Favorites Tools Help pack vy Ba DO Search Folders Address e U pC E Network Tasks CE6 E 7 f RealTime ad Add a network place View network connections c 4 L Printers and Faxes Set up a home or small office network Set up a wireless network For a home or small afFice View workgroup computers Show icons Far networked UPnP devices Wik de OG Now double click on RealTime folder 104 File Edit View Favorites Tools Help Qv li gt d yo Search Folders Hak Address G V BC RealTime Bottling plant File and Folder Tasks LJ Bottling plant PRI File 1 KB Make a new Folder Y Publish this Folder to the a es Web FEL CFG File EF 4 KB Other Places RealTimeProduct Configuration Settings 1 KB e Mahidhar_note Mahidhar notebo E My Documents S Shared Documents X Mv Computer a My Network Places If Real time folder is shared properly in first computer then from second computer you will be able to see above project files as shown above If it prompts any error message as shown below then it requires sharing RealTime folder at C Data Acquisition Studio manually again and repeat the above procedure i PC RealTime is no
57. iewer click on Icon Configuration data icon E Click on E icon to configure options then select Communication tab Option Share Email Communication Auto page Sampling Rate ka Tire Ou 30 Sec Sampling rate It is used to set data display time for Real Time Viewer User can select one from the following for real time monitoring Time out This is time set for generating time out errors related to real time viewer communication For example if IO modules and PC with data acquisition software are located at different places connected through Ethernet across different gateways and then user can adjust sampling rate and time out settings to avoid errors in communication When real time viewer is running please observe the following taskbar at the bottom side of the screen Pagel Sampling Rate 1 Sec Scan time 4 ms Here scan time should always be less than sampling rate Other wise communication errors will occur If PC and Modbus slave devices are connected by long distance network then there might be chances that scan time gets increased So check this and set 55 sampling rate more than scan time Also user can set time out settings to generate communication failure errors Maximum time out settings possible is 60 sec For example scan time is adjusted and time out setting 30 sec This means if scan time is more than sampling rate for more than 30 sec then communication errors will be generated
58. ist Pagel Page zoom Rate 1060 mSec Dot Then it will show list of Remarks available in a window Just double click on selected Remark and pointer will navigate to specific remark number automatically at specific date time 6 4 View Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj File F Edit E view V Displv D Page P Search 5 Help 1 Scale This is to display trend in monitor with various zoom rate Horizontally To view historical trend horizontally in screen Vertically To view historical trend vertically in screen Black background To set black back ground for historical trend White background To set white background for historical trend For ex Zoom 1 sec dot First check monitor current display setting If screen resolution is 1280 X 800 pixels then you will be able to see data around 900 sec as right side of the trend it shows digital values and it occupies remaining pixels 84 Display Properties Themes l Desktop Screen Saver Appearance Settings IIT AJ L Display Plug and Play Monitor en NVIDIA GeForce Fx S700LE Screen resolution Color quality EE More Highest 2 big v 1280 by 800 pixels EINE NE NN Troubleshoot VISI L y mm Ctrl 1 A omo Ctrl T a Foor All Ctr zoom by 100 mSec Dok zoom bv 1 Sec Dot zoom by 2 Sec Diot zoom by 5 Sec Diot zoom by 10 Sec Ciot zoom bv 20 Sec Ciot Zoom by 30 Sec Diot zoo
59. l Beran Inputs amp Counters 10 cards 68 If you wish to see Counter and Totalizer value as channels in main pages then they can be selected in Math channel and then select specific Math channel in Display pages configuration as shown attached Edit math expression Source Modify Tag Data Tag Name Mathi Device Type Math O anki Ns gn Lis rm S E IP E ddress d Log Type ler ible LogSpeed 1 Sec l Trigger by Time lt Data Byte Type la Byte LogMethod Instant olerance Range Low 99999999999999 9 Range High 99999999999999 9 Decimal fi Expression Conti Unit Deg c Select Counter Totalizer here Engineering Type Scale Transformation Enable nain Register Address fi Scale High 100 0 Data Type ouble Scale Low n o Event Alarm Type SetPoint Job2 Hysteresis 1 No l No Action No Action 0 2 No ji No Action No Action 0 3 No lt No Action No Action 4 no y No Action No Action 5 No No Action No Action 0 69 X Cancel 3 RealTime ontigur e Cx Si ANE BIE trimg anh Auto A an a en an an an eee p pose s d Mode Enable Fage Marks Speed l1 Sec Dot Direction Horizontal M Background Black Pen S5elect Hath channel here for display Mo Channel Color Width Lowy High Wo mete sl jo 100 0 2 uzs Mae Ah Apo poo 3 amas AEn
60. l of all the pen le The display Time period data to be exported Speed Mel Source List Destination List File Iw Pen file C Data Acquisition Studia RealTime Demal Demoi1 Pen csv e iv Event File C Data Acquisition Studio RealTimeDemolDernol_Event csv e X Cancel Range The display Select this option if it is required to export data specific to display screen Current view Time Period Select this option and enter start data end date start time and end time This is to select historical data with specific time period and then export to excel All Select this option is all the historical data needs to export to excel files Speed This is to select resolution for data archival 100 msec dot 1 sec dot 2 sec dot 5 sec dot 10 sec dot 20 sec dot 30 sec dot 1 min dot 2 min dot 5 min dot 10 min dot 30 min dot 10 min page 30 min page 1 hr page 2 hrs page 4 hrs page 8 hrs page day page week page and month page For ex If 1 sec dot selected then you can archive data once in a sec If 1 min dot selected then you can archive data once in 1 min Source List Tags available for selection for data export Destination List Tags already selected for data export gt Move Tag from source to Destination gt gt Move all Tags from Source to Destination _ Move Tags from Destination to Source 81 Move all Tags from Destination to Source Pen He Select path of data files where all the excel files dat
61. lect IO card for addition of IO modules into network Bank Select bank from 1 to 4 as per bank configuration IP address P address of the gateway say PC E converter May be all the IO modules are connected to PC E via RS485 Device Node address Address of slave device to be added to network 4 10 Option In Real time viewer click on Icon Configuration data icon 8 S RealTime Configure E S 8 AB Ro 7 Option Click on E icon to configure options 52 4 10 1 Share In Real time viewer click on Icon Configuration data icon E Click on E icon to configure options then select Share tab Option SEs C Do not share S Share data so other people can read it x Cancel Share do not share options are available for user selection If share option is selected then historical data available in the computer can be shared from other computers On selection of this share data shared folder will be created and following message will be shown Information Lol i 1 Ci Data Acquisition Studio RealTime Share Folder created For example you have some Modbus slaves like IO module recorder etc and wish to analyze historical data at different computer While opening project in the second computer directly link to the project file available under C Data Acquisition Studio through network configuration This will minimize the data transfer between Modbus slaves and the computers and make it more efficient b
62. m by 1 Min Dok zoom bv 2 Min Dot Zoom by 5 Min Dat zoom by 10 Min Cot zoom by 30 Min Cot zoom bv 10 Min Page zoom by 30 Min Page zoom by 1 Hour Page Zoom by Hour Page Zoom by 4 Hour Page Zoom by amp Hour Page zoom by Day Page zoom by Week Page zoom by Month Page Horizontally Vertically Bl Black background UU white background 85 6 5 Display Display measured values from historical data of C Wata Acquisition Studio ReallimeWemo1 prj FilefF Edit E View Displv D Page P Search 5 Help Leis see x 1 Scale 0 Dispi Tx Tren d Vie Event Alarm List 5 Report List Value List 6 5 1 Trend view It is to view historical trend Display measured values from historical data of C Data Acquisition Studio Reallime WDemo1 prj File F Edit E View Asu Page P Search S Help H NW lt gt aa a Zoom Size Y i ie E ES Event Alarm List 1 Scal ER 2 B Value List Tagi Rearmost Tag2 Tag3 Tag4 Tags Tag Tag v i Pagel Page Zoom Rate 155ec Dot Index Time 05 11 09 13 01 18 If 24 pens are configured in page1 and if it is required to view only 1 to 8 pens then select them in wndow as shown Tagi Rearmost Tage Tags Tag4 Tago Tage Tag niani Jl S RJ ISI ISI IST IST IST IS 86 Tag1 scale is 120 to 1000 Tag2 scale is 120 to 1100 If it is required to see both the scales the
63. monthly reports 48 Totalizer1 Source Al1 Action Enable Decimal 1 Period Sec Unit Cub Mtr Preset 0 0 Timer1 Type Daily Action Enable Time Hour 23 Min 59 Sec 59 Job1 Log Report Target Totalizer1 Job2 Reset Totalizer Target Totalizer1 Reset Totalizer1 historical data in order to log new data for the next day 4 8 Comments In Real time viewer click on Icon Configuration data icon 8 RealTime Configure dx ANA c gt 3 5M0 Timer Counter To a Click on El icon for Comments configuration 100 messages available for display of customized alarms Maximum 50 characters are allowed in each message and these comments can be assigned as Job function Log message in events at the Analog Digital Math channel configuration Ex Message1 Tank TK101 level High 49 i RealTime Configure EH Message Message messages Messaged Messagen Message Message Messages Message 10 Mlessagqei u bi RealTime Configure messages Modify Tag Data 192 168 0 112 olerance Register Type Input Register 71 scale Transformation i y Engineering High fo999999999999 99 Register Address K S cale High 100 00 Engineering Low 9999999399999 99 o zo oa eg Message_Messaget Jpn a AAA pes po 50 4 9 Project Auto configure In Real time viewer click on Icon Configuration data icon 8 2 RealTime Configure jg xe m mS Jo ad Modify O fie Project auto co
64. n 4 No v No Action No Action 5 No Y No Action No Action X cancel Device Type Display channel source Bank Display current Bank number Tag Name It is to define the name for each channel in maximum 9 characters Auto Update If you wish to modify Tag name and modify configuration deselect it Use Gateway Device Node address It is address of selected device type IP address Display current gateway IP address Log Type Enable Disable Select disable while a specific channel is not required at this time Select enable while a specific channel is required Log Speed It is the logging speed recording speed of measured data Select Log opeed column then choose 1 2 5 10 30 60 or 120 seconds Log Method The method of logging measured data Select the column and then choose the Log method of Instant Average Minimum or Maximum data Instant logging in the last measured data at the sampling interval Average logging in averaged measured data at the sampling interval Minimum logging in minimum measured data at the sampling interval Maximum logging in maximum measured data at the sampling interval Trigger Select various types like by time or by change or disable 31 By Time Data log based on Log Speed and Log Method By Change Depends on Tolerance setting Log speed and Log Method is disabled if this option is selected and if this option is selected sampling rate is fixed at 1 sec This option is selecte
65. n Digital Icon 123 to show all digital values in full screen alternatively in Menu click on Window and then click on Digital Maximum 24 channels can be displayed in each page and total 200 display pages available 63 Display real time measured value from C File F view PagelP Bul LanguagerL 3 d 4 pm E Trend Digital Page1 Event SR Arrange all Al channel digital Status caes Digital Page1 Pagel Pagel Sampling Rate 1 Sec Scan Time 1 ms start Th UMDAS Microsoft Th Recorder ENU Mi ga YR18 Manual 2 3P Y untitled Paint 5 wer v2 36 S BLA 4 13PM 0 Note Back ground color for each channel depends on display configuration as shown attached 64 RealTime Configure d iu axel SAEs te Da M Auto 2 E a E a E l e ec pas e ie o Made abe y Page Marks Speed 1 Sec Dot Y Direction Horizontal Pagel Background Black Mo Channel Color Width Low High ka Backward Be Forward 5 1 4 Display Bar Graphs Display real time measured value from C Data Acquisition File F View PagetFP Windowi Ww Language L HelprH Click on Bar Icon Hi to show Bar graphs in full screen alternatively in Menu click on Window and then click on Bar Maximum 24 channels can be displayed in each page and total 200 display pages available Display real time measured value from C File F Vier PagelP Bue La
66. n Ge geese UR ES 98 00 ERIN n 99 69 15 100 7 FREQUENTLY ASKED QUESTIONS eene nnn 107 O Information to user NOTE 0 Do not open IO Studio and Real time viewer at same time in your PC First complete IO module configuration by using IO studio software close IO studio then open Real time viewer O It requires to buy USB hardware lock Keypro from supplier to run RealTime viewer in PC One single license is required to run Real Time Viewer in single PC It is not required to purchase Hardware lock to view historical data in other computers via LAN With out hardware lock Real Time Viewer in Data acquisition software will run for 1 hr in demo mode 1 Introduction 1 1 Introduction Data Acquisition Studio DAS software is PC based data logging and Acquisition software It acquires data from Modbus RTU Modbus TCP slave devices like IO Modules Recorders Controllers etc and shows Real time data in PC in form of Trends Bar graphs Digital values etc and store data in PC for later archival DAS support up to 1024 tags One tag means one channel and it can be either Analog input or Analog output or digital input or digital output or Math channel 10 25 26 10 28 46 332 10 38 46 10 42 06 1 45 26 10 52 06 10 55 26 PN 05 15 09 05 15 09 9 05 15 09 05 15 09 05 15 09 05 15 09 1 2 System requirements P
67. n click on Trend scale List select the required tags y RS Tad Rearmast O irri iii iter rereirrrreiirreteiitireriiitiiitititiiii irri EN T acs Seek by Legend Seek by EventiAlarm Seek by Remark Trend Scale List AE Select All Scale option as shown attached Display measured values from historical data of C Data Acquisition Studio Reallime Wemot1 prj File F EditfE view V Disp Page P S5earch S HelprH 10 3i A 8 zoomsize E Select All Scale to view multiple display scale on Y xis File F Edit E Viewty Disply D3 PagelP SearchiS HelpiH e co lt ES ES S gt 9 m zooms MEET an Seale 000 0 y Hus Bras tag Scale AAA A A A a a A yn ses ml 976 0 776 04 856 07 664 0 734 07 552 0 612 07 nm Dak i lj 328 04 368 0 216 02 246 0 104 0 124 0 8 0 290 LE ns labios LT kda d peus dahi Z Bearer RR H M M s E Pol ES i 87 If it is required to change color width display scale of specific pen then do the settings in Real time viewer configuration as shown below The settings made at Real time viewer shall be retrieved in historical viewer also No separate display settings available for Historical viewer Baxe ISE HS HE AOF N Auto Display Pagel 1 la la Js s e e e e Jar a Ji H Mode Enable Page Marks Speed n Sec Dot Direction Horizontal Page Background Black Pen No
68. n water pump every day at 8 00 hrs and switch off at 10 00 hrs This application requires to Daily type timer which works with Real Time Clock Configuration settings are as follows Timer1 Type Daily Action Enable Time Hour 8 Min O Sec 0 Job1 DO Latch On Target DO1 Job2 No Action Timer2 Type Daily Action Enable Time Hour 10 Min 0 Sec 0 Job1 DO Latch Off Target DO1 Job2 No Action 3 RealTime Configure IZ 1 Se BNR NG E rt BO Timer Courter Totalizer Timer IT ea a ed ee ee bubus sm se Type Daily Action Enable Time Hour Minute lg D Jobi DO Latch On DO1 4 Job2 No Action 45 4 RealTime Configure HOxXS lanas l gt 3 M0 Timer Counter Totalizer apical aa Type Daily Action Enable Time Hour Minute 10 x ln kd Jobi DO Latch Off DO1 4 Jobe No Action 4 7 2 Counters In Real time viewer click on Icon Configuration data icon 8 Click on ES icon for Tools configuration and then click on Counter tab Maximum 50 timers available for configuration 1 RealTime Configure SZ PIL He HEH HT Timer Counter Totalizer Counter 1 t 22 tes fe Ce ce se ao ae ae LT Mame Conti Desc Counter 1 Unit No Preset o Event Alarm Mo Type SetPoint Jobi Job2 1 H 100 Log Alarm No Action 2 EN foo Log Alarm AutoAck No Action Name Defines the name of counter Desc Defines the description for a specific counte
69. nd will go to specified date time Search by a specific time Time 3 15 2009 10 05 07 AM x Cancel 6 7 2 Period of Time It is to search data specifying time interval Click on e icon to search data by a period of time alternatively click on Menu then select By period Search by a period of time E From 5115 2009 10 00 28 AM To 5115 2009 10 20 55 AM X Cancel Enter Start date end date start time and end time for the data to be searched and click on OK then it displays trend in specified range To take print click on Print icon to open Print viewer and then click on 3 for printing the trend 96 a Bug Page of 1 amp 2 A Zoom EM se Click here to Print trend Tagg Ta lU Tagil Tagiz Tagl3 Tagl4 i Tagl3 Tagi amp Seek by Legend Seek by Event Alarm Seek by Remark Trend Scale List 6 7 3 By TagName It is to select specific trend for display For ex You have configured 8 tags in page no 1 to check tag1 clearly you wish to see only trend1 Then select this option and select the required tag Bv Tag Mame By Event Alarm By Remark y Tagi Rearmost y Tage T v Tags w Tag4 y Tags Forefront oes SEE T EA Click here Click on Seek by TagName and then select the required Tag to display in trend If it requires viewing display scale click on Trend scale list and select the
70. nfigure Click on icon for Project auto configure If RS232 is selected in the Bank then if all the IO modules are connected in RS485 network then it is possible to acquire data base of all the IO modules specifying start and end address of IO modules using Project auto configure function 37 Auto configuration AE Device Type no Card Bank n Q Protocol Modbus_Rs232 le Auto update Node address From 1 ff Ok AX Cancel Device type Select IO card for addition of IO modules into network Bank Select bank from 1 to 4 as per bank configuration Auto update Select if it is required to acquire data base of IO modules and give tag name for the channels automatically From Start address of IO module To End address of IO module Click on OK to add all the IO modules into network configuration If Ethernet is selected in the Bank then it requires IP address of the Gateway and address of each of the IO module to add new IO module each time 91 Note Provision is not available to enter range of IO modules like RS232 RS485 Auto configuration Device Type Jo Card Bank 2 Protocol Madbus TCP lg Aubo update IP address Example 192 166 0 111 g Please key in IP here and then press button Eo IP List add it to the IP list S Please select one IP Form IP List and then press button to remove it le Use Gateway Device Node address 1 x Cancel Device type Se
71. nguagerL DALA d mm ES trend A Digital Page1 BE Digital Event ES Arrange all 33 All channel digital 65 4 Display real time measured value from C Data Acquisition Studio ReallimeWemo1 prj File F Yiew Page P Window W Language L Help H ooo uns e sss T y mao l m sss du E I j 1200 0 1300 0 1400 0 1600 0 1600 0 1700 0 1068 0 1158 0 1248 0 1428 0 1428 0 1518 0 936 0 1016 0 1096 0 1256 0 1256 0 1336 0 804 0 874 0 944 0 1084 0 1084 0 1154 0 672 0 732 0 792 0 912 0 912 0 972 0 540 0 590 0 640 0 740 0 740 0 790 0 408 0 448 0 488 0 568 0 568 0 608 0 276 0 306 0 336 0 396 0 396 0 426 0 144 0 164 0 184 0 224 0 224 0 244 0 12 0 22 0 32 0 52 0 52 0 62 0 120 0 120 0 120 0 120 0 2100 0 2300 0 2400 0 2500 0 1878 0 2058 0 2148 0 2238 0 1656 0 1816 0 1896 0 1976 0 1434 0 1574 0 1644 0 1714 0 1212 0 1332 0 1392 0 1452 0 990 0 1140 0 1190 0 768 0 888 0 546 0 636 0 324 0 384 0 102 0 132 0 120 0 120 0 Pagel Pagel Sampling Rate 1 Sec Scan Time start Ty UMDAS Microsoft W Wy Recorder ENU Micr pa VR18 Manual 2 3P p j untitled Paint Viewe RIUS 4 25pm 0 Note Fill color in graph and display range for each channel depends on display configuration 5 1 5 Display Real Time Trends Display real time measured value from C Data Acquisition File F View PagetFP Window Language L HelprH Re E SEF Click on Trends Icon des to sh
72. nt can create two jobs Various types of jobs can be selected 4 5 2 Jobs The following jobs are available for configuration to be executed on an event No Action Do nothing Log Alarm Auto Ack Record alarm with acknowledgement automatically Log Alarm Record alarms Log Event Record events Send Email Send email if it is configured on an event Sound Buzzer Sound the buzzer on an event DO Latch On Set digital output relay on and then select Target say DO 1 The relay is latched when it is activated Digital Output relays will be shown if digital output card is configured and available in database DO Latch Off Set digital output relay off and then select Target say DO 1 The relay is latched when it is activated Digital Output relays will be shown if digital output card is configured and available in database DO Process Set digital output relay on for process high or low and then select Target from DO 1 to DO 6 The relay is not going to be latched when it is activated Digital Output relays will be shown if digital output card is configured and available in database 33 Enable Timer Start the timer and then select Target from Timer1 to Timer 50 or all Timers Disable Timer Stop the timer and then select Target from Timer1 to Timer 50 or all Timers Preset Totalz Start the totalizer with a preset value and then select Target from Tolz 1 to Tolz 50 It requires configuring totalizer via tools and enabling it to appear
73. on All Channels Digital AA Language Mi gt a EE Es Trend Bar ME Digital E Event Alarm List Event i Login a Arrange all 2 Commerror FEE All channel digital 3 Lommerror El ParnnErenr 67 5 1 7 Display Counter amp Totalizers Display real time measured value from C Data Acquisition File F View PagerFP Window Language L HelprH eB SER NH PR SZ Click on Status Icon alternatively in Menu click on Window and then click on Status and then click on tab Tools to show status of Counters amp Totalizers It display status of all 50 counters and 50 Totalizers If IO cards are available in network then other tabs with name Tools appear under status and they displays status of Digital Inputs Counters Digital Outputs based on selected IO card in the network Display real time measured value from File F View V AAA LanguagerL IDe gt 5 m zm i E Event m Conti zL Arrange all 2 Cont2 35 5 All channel digital 3 Conta Status d finnta File F view window Language L HelpiH LO Ade JE E mj me m These tabs MPa Ad TE automatically based on selected 10 cards in network No Name value Desc 1 E O No Counter 1 2 Cont T 3 Cont3 T 4 Cont4 l 5 Lont5 1 D Cont T F Cont T H Cont T g Cont T 10 Cont 10 O Status of Status of 58 counters Digital Outputs and 56 Totalizers This tab is always visible by Status of Digita
74. orted and they can be used in expression while writing formula 4 5 6 Digital Outputs 2 Modify Tag Data Device Tvpe Bank Tag Mame DO1_4 Protocol Modbus TCP Use Gateway Device Node address IP address X Cancel The above screen is useful to change name of tag after de selecting auto update In real time these digital outputs should be triggered by jobs defined at events 4 5 6 1 DO Example Temperature Channel 1 Al1 When temperature Al1 gt 80 C then switch ON digital output When temperature Al1 lt 40 C then switch OFF digital output 37 Modify Tag Data Y Auto update Bank Tag Name lY Protocol Modbus TCP Use Gateway Device Node address 3 IP address Device Type Log Type le LogSpeed hse 2 Trigger Data Byte Type sve y LogMethod Tolerant Range Low 2000 Range High soo Decimal y Gain h Offset fo 8 8 Unit K o Sensor Type PT100 Erice Register T Scale Transformation Disable Engines d r ddi Scale High 250 1 Engineering Low 99999999999999 9 D Scale Low 200 8 AE Type SetPoint Jobi Job2 Hysteresis LIR ellep Pokatchon pors fw amp Atn i 2 AA A E X Cancel 4 5 7 Math Inputs In Real time viewer click on Icon Configuration data icon E Now click on Add button 2 RealTime Configure Click here
75. ow Real Time Trends in full screen alternatively in Menu click on Window and then click on Trend Maximum 24 channels can be displayed in each page and total 200 display pages available 37 Display real time measured value from C FilefF View PagelP Bgm LanguagerL Sas TS par Ta BE Digital 1000 0 Event Arrange all K 888 0 HE All channel digital EE Status K 776 0 66 4 Display real time measured value from C Data Acquisition Studio ReallimeWemo1 prj File F Yiew Page P Window W Language L Help H 5g BSB INE E 16 09 18 16 10 58 6 1 j 15 14 18 bh z 6 2 8 16 24 18 16 25 58 05 08 09 05 08 09 05 0 05 08 09 E 05 08 09 05 08 09 05 08 09 a B Tagi Tag Tigh Tag Tags a viE w Tag Tagilo Tagli Tagi2 Tagi3 aai Tagl6 Pagel Pagel Sampling Rate 1 Sec Scan Time UY UMDAS Microsoft W Ty Recorder_ENU Micr P VR1S Manual 2 3P p i untitled Paint XT Real_Time_Viewer amp JLS 4 29 PM 0 Note Trend color and trend width for each channel depends on display configuration 5 1 6 Display All Channel Digital Display real time measured value from C Data Acquisition File F View PagerFP Window Language L HelprH ama SAI E gt EOOOO EH UMM Click on All Channel Digital Icon 5 5 to show all channels as digital values in full page alternatively in Menu click on Window and then click
76. ows Real time viewer screen Data Type Float Float Float Float Float Float Float Float in PC E Event Alarm List Ack Type Source Active Time Clear Time Value Content 100 00 1 Login System 04 09 09 13 53 30 90 00 70 00 60 00 50 00 40 00 30 00 20 00 10 00 Digital Page1 i Page1 44 36 13 6 3 9 09 D4 19 D4 100 00 90 00 70 00 60 00 50 00 40 00 30 00 20 00 10 00 100 00 90 00 70 00 60 00 50 00 40 00 30 00 20 00 10 00 100 00 90 00 70 00 60 00 50 00 40 00 30 00 20 00 10 00 S 100 00 90 00 70 00 60 00 50 00 40 00 30 00 20 00 Ma gt anes Pagel Pagel Sampling Rate 1 Sec Scan Time 60 ms 100 00 90 00 80 00 70 00 60 00 50 00 40 00 30 00 20 00 1 00 00 90 00 80 00 70 00 60 00 50 00 40 00 30 00 20 00 10 00 If it is by Ethernet screen shots will be as shown below 25 Auto configuration Device Type Ifa Card hal Bank 2 Protocol Modbus TCP We Auto update IP address Example 192 168 0 111 g Please kev in IP here and then press button to IP List 192 168 0 112 add it to the IP list an Please select one IP Form IP List and then press button to remove it W Use Gateway Device Node address 5 x Cancel O Note When Ethernet is used in a bank it is not possible to add many IO mod
77. r on the display Unit Defines the unit of counter Preset Defines the preset value for the counter The counter starts from a preset value 46 Event Defines the type set point Job1 or Job2 Type Select one of three options None Process Hi Process Low Set point Defines the set point of process value to trigger the counter Job1 Job2 various jobs as described in 3 6 2 2 jobs for each counter 4 7 2 1 Counter Example Supervisor wants to know the number of occurrence of an event in a day say pressure switch signal high Digital input1 is used for Pressure switch High signal indicates High pressure Low signal indicates normal pressure Digital Input Event1 Type H Job1 Inc Counter Target Counter1 Timer1 Type Daily Action Enable Time Hour 23 Min 59 Sec 59 Job1 Log Report Target Counter1 Job2 Reset Counter Target Counter Reset Counter1 historical data in order to log new data for the next day If values meet the following conditions DAS will change notation from traditional to scientific the value is more than 10 5 or less than 1 1045 the value digit length in display exceeds the allowed range Ex Up to 5 digits counter displays value directly Say 0 99999 100000 will be shown as 1E5 that means 5 zero s after 1 4294967295 will be shown as 4 29497E9 etc 4 7 3 Totalizers In Real time viewer click on Icon Configuration data icon E Click on 5 icon for Tools configuration and then
78. required tag 97 6 7 4 By Alarm Event It is to view and point to data based on selected event way Ey Period By Tag Mame By Event Alarm By Remark Mo Ack Type Source System System System System System Active Time 06 03 09 11 18 12 06 03 09 11 18 3 06 03 09 11 20 35 06 03 09 11 23 11 06 03 09 11 23 11 ES See E Click here Mo ck Tvpe Source Active Time Clear Time Values 1 Login System 06 03 09 11 18 13 2 Logout System 06 03 09 11 18 34 3 Login System 06 03 09 11 20 37 4 Logout System 06 03 09 11 23 11 5 Login System 06 03 09 11 23 11 5M HiAlarm 06 03 09 11 28 18 Terminated 7 U HiHiAlarm Tagi 06 03 09 11 28 23 Terminated 663 0 Double click Seek by Tag Name Seek by Event Alarm Seek by Remark Trend Scale List Select the required event Alarm then double click on it Then pointer in the trend will move to specific time at which event Alarm is triggered 6 7 5 By Remark It is to view and point to data based on selected Remark HelprH Bv Time D By Period By Tag Name By Event Alarm By Remark 98 Remark Time 0603109 11 25 23 Double click Seek by Tag Name Seek by Event Alarm Seek by Remark Trend Scale List Ho Remark Time Page Content X 1 05 15 09 10 36 28 Page OK 05 15 09 10 41 06 Irregular Double click All the list of Remarks will be shown in window at the bottom s
79. s 132 1168 0 112 Select 28 JOStudio BrainChild File About Module ID 5 Stop Comms 10 86 Module Type 103 Software Version 2 Modbus Value Label Address 30001 615 Tupe SW Version Description of Modbus Register 30002 0 Current Input 1 30003 0 Current Input 2 30004 0 Current Input 3 30005 0 Current Input 4 30006 0 Current Input 5 30007 0 Current Input 6 30008 0 Current Input 7 30009 0 Current Input 8 30010 21845 Input Status 30100 73 DIP Switch 40121 38400 Baud Rate 40122 D Parit 40123 1 Stop Bit 40124 D Reply Delay Move Mouse pointer over Value for Description Add A Tag Je Auto update Device Type LO Card Protocol Madbus TCP Select IO card in Device type Select Bank properly as per Bank settings Select Use Gateway and Select address of IO Module Enter IP address of PC E converter which is connected to IO modules via RS485 converter Click on OK If IO module is connected properly to PC via PC E then tag data base of IO module will be added as shown attached 29 RealTime Configure 7 Add Mo Device Type Data Type All List A11_1 e Yes 5j 192 168 D a IO Card Float 1 LO Card 1 ATT 1 Z Yes 5 192 168 0 112 1 0 Card A Float AITS_ 1 2 Yes 5 192 168 0 112 1 0 Card AI Float AIT4 1 2 Yes 5 192 168 0 112 1 0 Card AI Float AIIS 1 2 Yes 5 192 168 0 112 1 0
80. s then RealTime folder may become big size with large storage data If it is more data it is difficult to send project files with data by Email So before sending project configuration files you may need to take out large data files first and then send only configuration files You may first copy total RealTime folder to your desktop and then remove the data files from RealTime folder at your desktop such that it will contain only configuration files Then zip Realtime folder and send it to us 60 5 Real Time Viewer 5 1 Opening project If it is a new project refer earlier section and create a new project If it is existing project open the project by selecting appropriate path If communication is established between PC and Modbus Slave modules over the selected bank then after opening Real time viewer By default the following screen will appear which shows all the components like Events Alarm list Bar graphs Digital values and Trends 5 1 1 Display Arrange All Display real time measured value from C Data Acquisition 5 File F View PagerF Window Language L HelprH Click on El icon to display Digital values trends bar graph 8 events alarm list in one screen Each of the above will be shown in separate windows alternatively in Menu click on Window and then click on Arrange All S Display real time measured value from C File F View v PagelP ARNO Language k A o
81. saeaieurontips a iad a R 46 4 7 3 MOAZES epee ete nee ene oia 47 AiO COMEN So oe De 49 49 UPROJECT AUTO GONEICURES a o to da 51 4 10 OPTION ces A id 52 A Sha TTT 53 A M ME A D NEM TB T o3 2 ND Meere sla Eae 1 eT tH HIC 55 c 0 T 5 Ha i o LT 56 4 11 PRINT CONFIGURATION eee a ERES o6 4 12 BACK A dM EI M M MM LE LU 58 4 12 1 Project and Data backup saci sese eee 58 4 12 2 Restoring Project with Data sese 60 A123 Sending Projectile sm T 60 9 REALTIME VIEWER 252enbwustoe dE eter 61 Owl OPENING PROJE C TTT 61 5 1 1 Display Atrange T 61 5 1 2 SDA ENON esas E 62 5 1 3 Display Digital Values eee 63 5 1 4 Display Bar Graphs ereccion ai cre ee A eae eae 65 5 1 5 Display Real Time Tenda sss 66 5 1 6 Display All Channel Digital sese 67 5 1 7 Display Counter amp Totalizers sees 68 5 2 DATA DYNAMIC EXCHANGE DDE 70 6 HISTORICAL VIEWER eene rennen nnne nnn nnne nnn nnn nnn nnn 76 MEME ss 76 6 1 1 A e gece OE E OO calender 76 6 1 2 MENU lt T cba 78 0 2 EXPORTDATA TOE FE ear MEI MM HMM EI NM M IMEEM M UM 80 28 o A o ee ee 82 5 a O A 84 e o PO O a 86 6 5 1 Trend VIEW TT 86 6 5 2 Events Te BIS an ee en eee A EEEE EE EE 88 6 5 3 REDONS EIS Tsg aa a ea 89 A A o E a E EEE A E E E A A EE 93 0 0 PAE SELECTION m m 94 OF ce E AP E A EO 95 6 7 1 EVO is 95 6 7 2 a 96 6 7 3 zie surreal ea a 97 6 7 4 a 98 6 7 5 ETE SMA A en g
82. t accessible You might not have permission to use this network resource Contact Ehe administrator of this server to Find aut if you have access permissions Access is denied Procedure to open historical viewer from another computers in network After completing above setup it requires to open Real time viewer in second computer and project file of first computer via My network places as shown below Open Real Time viewer Click on c icon Mu Network Click on Places Select Entire Network and then double click it Look in a Mu Network Places a OCE 105 Look in d Entire Network E Lo Microsoft Windows Network Mu Recent Documents Select Microsoft windows Network and double click it Then select work group and then select the First computer Look in Y PCO1 PC1 T RealTime Mu Recent Documents Double click and rs open the project file Then the following message will be prompted and open Historical viewer Information Display measured values from historical data of MPC1 RealTime a prj File F Edit E View Disply D Page P Search S Help H i CW Bj Sj Fo E roms EEE 1 Scale 116 00 40 4 1055 19 09 Instead of opening above historical viewer if it prompts the following message then check computer name and description Make sure that computer name does not have too many characters Read Project Mame is NULL 106
83. talizer Reset Totalizer Enable Totalizer Disable Totalizer Preset Counter Reset Counter Increase Counter Decrease Counter Log Report Reset Min Max Avg and Log Message Y Project Auto configure option available Generate tag data base automatically once IO modules are connected to the network and create a new project Y Supported Math functions SIN COS EXP SQRT LN LOG ABS POW ROUND HI LO INV TG CTG ASIN ACOS and ATG Y Source of Math channel Analog inputs Math channels Counters and Totalizers Y Data Types 2 byte 4 byte and 8 byte Decimal 0 to 4 1 3 2 Historical Viewer v Historical trend v Historical Alarms Events v Reports Daily Weekly amp Monthly Y Display Historical values in tabular column Y Mark Remarks on data Comments v Search data by Time Timer Period Event Alarm tag wise and Remark v View trends both Horizontally and Vertically v Zoom out amp Zoom In Y Display view options available at 1 sec dot 2 sec dot 5 sec dot 10 sec dot 20 sec dot 30 sec dot 1 min dot 2 min dot 5 min dot 10 min dot 30 min dot 10 min page 30 min page 1 hr page 2 hr page 4 hr page 8 hrs page day page week page and Month page Y Display white back ground black background v Export data and alarms events to CSV files Specify time or time period or all v Print trend view Event Alarm list Reports amp Tag Values 1 3 3 Sample Applications Data Acquisition Studio Software in PC will
84. th channel and two jobs are available in every event same as Analog input channel Math channels are virtual channels It contains measured value based on the equations These values can be recorded similar to physically connected Analog inputs and display digital values trends bar graphs etc 4 6 Display Configuration P In Real time viewer click on Icon Configuration data icon 8 2 RealTime Configure HO X Ed Display Config 42 Click on icon for display configuration 3 RealTime Configure ux SS 5 sE t e NO Z Auto Pagel E E E a a a a a Mode Enable ka Page Marks Speed i Sec Dot Direction Horizontal T Pagel Background Black Fen Mo Channel Color Width Low High 1 TE 5 TIE a 0 Dn 100 00 2 CE E oa SEC E ef Forward Maximum 200 display pages available for user configuration In each page maximum 24 tags are allowed per page Mode This is for page enable or disable Page Marks This is the name for specific page Ex Section Kiln Maximum 38 characters are allowed Speed This is real time trend display resolution Select one of the options in 1 sec dot 2 sec dot 5 sec dot 10 sec dot 20 sec dot 30 sec dot 1 min dot 5 min dot 10 min dot 10 min page 30 min page 1 hr page Direction Selects the trend direction horizontal or vertical Background Defines the background color of Trend mode in black or white Pen Defines a specific chann
85. tion software want to run DAS Real time viewer in 3 different computers Do need to buy 3 nos hardware lock Yes It is required to buy 3 nos USB based hardware lock Keypro have only COM port in PC don t have USB port How can run DAS software It requires another PC with USB port Serial port based hardware lock is not available want to run Real Time viewer in single PC want to view historical data in other 2 computers in LAN How many hardware locks need to buy 107 It requires purchase of single hardware lock for Real Time Viewer It is not required to have hardware lock Keypro to view historical data in another computers via LAN 10 11 12 13 14 15 16 17 18 Can connect DAS software to third party devices via Modbus Yes this is possible in future Can connect Recorder Controllers to DAS software Yes this is possible in future Can send email from DAS software Yes this is possible want to search data and then export data to excel Is it possible Yes it is possible Can display Real time trends digital values bar graphs using DAS software Yes it is possible How many trends can view in single page and how many display pages are available 24 pens page and maximum 200 display pages Can exchange data from DAS to another PC How it is done Use Dynamic data exchange DDE Can switch on Digital Outputs from DAS software
86. ts and alarm list Display Report Display values list Export data into excel Copy curves to clipboard Remark write a comment oearch by specific time Search by a period of time Fast back ward for data monitoring Backward Forward Fast forward Zoom out Zoom in Zoom all Zoom by time Zoom by value Navigate to next page Close historical viewer and return to Main program Tf B Black background W White background Show graphical representation horizontally Show graphical representation vertically 6 1 2 Menu Bar Display measured values from historical data of C Data Acquisition Studio RealTime Demo1 prj FilefF Edit E View Displv D Page P Search 5 Help Las m ES ise A Scale 0 f Open Chro Print b Recent K Exil Import Ckrl Alt I E Export Ctrl Alto Clear iCErl AlE4 L de Copy Chrl AlE C Remark Ckrl AlE2 R Import Option Import reserved for future Export To export data to excel Clear To clear the clipboard Copy To copy the current screen image to clipboard Remark To enter custom comments by user Import Option To refresh historical data as per set time interval 78 A R y pi L U J zoom In Ctrl I C Zoom Out Chr T C Zoom Al Ckrl zoom by 100 mSec Dot zoom by 1 Sec Dat zoom bv 2 Sec Duat zoom by 5 Sec Diat Zoom by 10 Sec Dat zoom by 20 Sec Dat zoom bv 30 Sec Dot Zoom by 1 Min
87. ules to the tag data base at one step It requires adding each IO module individually RealTime Configure Ox 8 s HN BO Na E ES No Device Type Use Gateway Made IP Device Type S Type Data Type All List AI 1 2 Yes 5 192 168 0 112 I O Card Float 1 NO Card_1 AI 1 2 Yes 5 192 168 0 112 1 0 Card A Float AHS 1 2 Yes 5 192 168 0 112 1 0 Card AI Float All4 1 2 Yes 5 192 168 0 112 1 0 Card AI Float AIS 1 2 Yes 5 192 168 0 112 1 0 Card AI Float Ae 1 2 Yes 5 192 168 0 112 1 0 Card AI Float AI 1 2 Yes 5 192 168 0 112 1 0 Card AI Float AHS 1 2 Yes 5 192 168 0 112 1 0 Card AI Float 4 4 Adding of new lO modules into Network 4 4 1 Add new IO module by RS232 RS485 Make sure that IO module is connected to PC via RS485 converter Bank setting is made properly for RS232 say at Bank In Real time viewer click on Icon Configuration data icon 8 26 RealTime Configure AHE Sn 9 Mo Device Tvpe Use Gateway NodesIP Device Type Tag Type Data Type Click on Add button Add A Tag Amka W Auto update Device Type luo Card Bank jt y Tag Name UEO Protocol Modbus R5232 Mode address IP I W OK X cancel Select Bank properly Enter node address of the IO module and click on OK If the module is connected properly it acquire data base of selected IO module automatically RealTime Configure dmm elete Data Type Float Device Type Tag Type AI
88. y using available resources through network configurations 4 10 2 Email This is to send email on an event like alarm In Real time viewer click on Icon Configuration data icon 8 99 Click on E icon to configure options then select Email tab The default Port number 25 is used to send email from STMP server If your network administrator configured different port in your LAN for accessing internet email then you have to modify the port number accordingly Option Sie EJ Share Email Communication Auto page Please Fill in the blanks so Ehe email Function can be activated SMTP Server Host company com Port 25 User John Email Address Sender sales company com Receiver service company com c X Cancel To send an email for any event the procedure is as follows Set SMTP server details as below Please contact system or network administrator for the server details if your computer is connected in LAN Host Port User name From Sender email address To Receiver email address Max 10 email addresses can be selected In case email is successful it delivers as follows Type HiAlarm Source Tag1 ActiveTime 05 08 09 13 31 04 Value 50 Comment Levelhigh If Email is failed to deliver then it prompts the following error message In this case it requires checking all the email settings 54 Real_Time_Viewer E e Socket Error 11004 4 10 3 Communication In Real time v