1. 12 Technical 13 Contatti sane Sidi Er rene ERE Va 14 Installation Guide Windsensor IEN101010 3 Notes on this Guide SMA Solar Technology AG 1 Notes on this Guide This installation guide describes how to install and commission the anemometer Store this installation guide where it will be accessible at all times 1 1 Validity This installation guide is valid for the upgrade kit of the anemometer 1 2 Target Group This installation guide is intended for the installer 1 3 Symbols Used The following types of safety instructions and general information appear in this document as described below i DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury i WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury CAUTION NOTICE indicates a situation that can result in property damage if not avoided Information Information provides tips that are valuable for the optimum operation of the product 4 Windsensor IEN101010 Installation Guide SMA Solar Technology AG Safety 2 Safety 2 1 Appropriate Usage The anemometer is a sensor intended to measure horizontal wind force outd
2. Accuracy 0 5 Measuring range 0 8 m s to 40 m s Resolution 0 4 m Proportional frequency to wind force 100 Hz at 40 m s 60 m s are also possible briefly Wind run Environmental conditions during operation Ambient temperature 25 Cto 60 C Mounting location Outdoors When free of ice Installation Guide Windsensor IEN101010 13 Contact 8 Contact SMA Solar Technology AG If you have technical problems with our products please contact our Service line We require the following information in order to provide you with the necessary assistance Sensor model e Communication device e Measured values SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany www SMA de SMA Serviceline Inverters 49 561 9522 1499 Communication 49 561 9522 2499 Fax 49 561 9522 4699 E Mail Serviceline SMA de 14 Windsensor IEN101010 Sunny Central SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany www SMA de SMA Serviceline Tel 49 561 9522 299 Fax 49 561 9522 3299 E Mail SunnyCentral Service SMA de Installation Guide SMA Solar Technology AG Legal Restrictions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of eval
3. System Monitoring Anemometer Installation Guide Windsensor IEN101010 98 0025210 Version 1 0 Cn SMA Solar Technology AG Table of Contents Table of Contents 1 1 1 1 2 1 3 2 2 1 2 2 3 3 1 3 2 3 3 4 4 4 2 4 2 1 4 2 2 5 1 5 2 6 1 6 2 Notes on this 4 Validiy ua ie tee d utto ei ina ne Ga cae al 4 Target Group ese eau s o EP SEE e e 4 Symbols 4 Safety od op vede doa eR ERU ERU RU 5 Appropriate renna E qua bu d 5 Safety 5 Unpacking Pen a odes m BER Pc Ua dira 6 cubo A E E 6 Cabling 6 Selecting the Mounting Location 7 Mounting the Device 8 Mounting the anemometer on a 8 Mounting the anemometer on a wall 8 Wall Mounting with Mounting 8 Wall Mounting with Wall Mounting Bracket 9 Electrical Connection 10 Meee Re Up AA 10 Connecting the Sensor to the Sunny SensorBox 10 Decommissioning gt ia 12 Disassembling the 12 Disposing of Ihe Sensor
4. chnology AG This also applies to the provision or non provision of support activities Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements of the manvfacturer SMA Factory Warranty The current guarantee conditions come enclosed with your device These are also available online at www SMA de and can be downloaded or are available on paper from the usual sales channels if required Trademarks All trademarks are recognized even if these are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by SMA Solar Technology AG is under license SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E Mail info SMA de 2004 to 2010 SMA Solar Technology AG All rights reserved Installation Guide Windsensor IEN101010 15 SMA Solar Technology AG
5. echnology Mounting the Device 4 2 2 Wall Mounting with Wall Mounting Bracket Position Number Description A 1 Wall mounting bracket B 4 Hex screws 4 Washers D 4 Screw anchor The optional wall mounting bracket is required for wall mounting using the wall mounting bracket 1 Determine the mounting position taking into consideration the requirements of the mounting location 2 Attach the wall mounting bracket to the wall using screws screw anchors and washers 3 Mounting the anemometer on a mast see page 8 4 Attach cables closely to the wall mounting bracket using cable ties or similar attaching material M The anemometer is mounted Installation Guide Windsensor IEN101010 9 Electrical Connection SMA Solar Technology AG 5 Electrical Connection 5 1 Circuit diagram Position Description A Reed sensor 5 2 Connecting the Sensor to the Sunny SensorBox 1 Open Sunny SensorBox as described in the Sunny SensorBox Installation Guide 2 Unscrew the cable gland s lock nut on the top left of the Sunny SensorBox and remove the filler plugs 3 Thread the sensor cable through the lock nut and the cable gland at the top left into the Sunny SensorBox enclosure 10 Windsensor IEN101010 Installation Guide SMA Solar Technology Electrical Connection 4 Connect sensor to connection F3 Wind of the Sunny SensorBox The polarit
6. er with 3 m output cable Mounting angle Screws Screw anchor Straps Washers mim ojoj gt NI N N N 3 2 Cabling Recommendations In the event that the pre configured output cable is too short please note the following information when purchasing a longer cable e Cross section min 2 x 0 25 mm min 2 x AWG 24 Tip you can also use a 4 core line 4 x 0 25 mm External cable diameter min 4 5 mm max 6 mm maximum cable length may not exceed 30 m e UV resistant for outdoor use only 6 Windsensor IEN101010 Installation Guide SMA Solar Technology Unpacking 3 3 Selecting the Mounting Location e mounting location must not be sheltered from the wind or in the lee of objects such as chimneys or satellite systems anemometer must be mounted in an upright position otherwise water can enter the anemometer and destroy it If possible install the anemometer in the center of flat roofs Installing the anemometer at the edge of the roof may cause air turbulence that may distort the measuring results Observe the pre configured cable length of 3 m The cable may be cut or extended to a maximum of 30 m Installation Guide Windsensor IEN101010 7 Mounting the Device SMA Solar Technology AG 4 Mounting the Device 4 1 Mounting the anemometer on a mast 1 Determine the mounting position taking into consideration the requ
7. irements of the mounting location Attach the mounting angle using the enclosed clamp at the top end of the mast see Place anemometer with the screws in the wide recesses of the mounting angle see and rotate the anemometer up to the end of the narrow recess see Tighten the screws below the anemometer Attach cables closely to the mast using cable ties or similar attaching material The anemometer is mounted 4 2 Mounting the anemometer on a wall 4 2 1 Wall Mounting with Mounting Angle p If anemometer is mounted directly on the wall turbulence may occur which reduces e 1 the precision of measurements a We recommend using a wall mounting bracket for wall mounting see chapter4 2 2 Wall Mounting with Wall Mounting Bracket page 9 The wall mounting bracket enlarges the distance to the wall and avoids turbulence The accuracy of measurements is increased Determine the mounting position taking into consideration the requirements of the mounting location Attach the mounting angle on the lateral end of the wall using screws and screw anchors see Place the anemometer including screws into the wide recesses of the mounting angle see and rotate the anemometer to the end of the narrow recesses see Tighten the screws below the anemometer Lay cables on the wall The anemometer is mounted Windsensor IEN101010 Installation Guide SMA Solar T
8. oors The provided performance data can be processed by the Sunny SensorBox Use the anemometer exclusively for purposes indicated in the installation guide and the indicated application range Use only SMA Solar Technology AG original accessories or accessories recommended by SMA Solar Technology Read the accompanying documentation for the anemometer and the communication product carefully before connecting the anemometer 2 2 Safety Precautions General safety precautions to avoid bodily harm Lay cables so that no one stands on them or trips over them e Work on rooftops entails a safety risk and requires special safeguards to be implemented General information in order to avoid damage to the device e Damage to the sensors as a result of incorrect connection to the Sunny Boy Control Plus or Sunny Central Control Before connecting read the corresponding installation guide and use the enclosed circuit diagram when commissioning the Sunny Central Control Integrate the sensor into the existing lightning protection e Protect your PV plant components against overvoltage from outside by connecting the sensors to an overvoltage protector When using the sensors with the Sunny Central the corresponding overvoltage protectors can be ordered as an option from Sunny Central Installation Guide Windsensor IEN101010 5 Unpacking SMA Solar Technology AG 3 Unpacking 3 1 Packing List Position Number Description Anemomet
9. uating the product or its correct implementation is allowed and does not require permission Exclusion of liability The general terms and conditions of delivery of SMA Solar Technology AG shall apply The content of these documents is continually checked and amended where necessary However discrepancies cannot be excluded No guarantee is made for the completeness of these documents The latest version is available online at www SMA de or from the usual sales channels Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following Damages during transportation Improper or inappropriate use of the product Operating the product in an unintended environment Operating the product whilst ignoring relevant statutory safety regulations in the deployment location Ignoring safety warnings and instructions contained in all documents relevant to the product Operating the product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond statutory limit values n case of unforeseen calamity or force majeure The use of supplied software produced by SMA Solar Technology AG is subject to the following conditions SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by SMA Solar Te
10. y of the cables is arbitrary i iP ip ca Gi OMM F o P E Wind IP EXT e o 5 Manually tighten the sleeve nut to the cable gland torque 0 8 6 Lay cable using suitable fastening material MI The anemometer is connected You can now put Sunny SensorBox into operation Installation Guide Windsensor IEN101010 11 Decommissioning SMA Solar Technology AG 6 Decommissioning 6 1 Disassembling the Sensor 1 Reset the configuration of the sensor in the communication device 2 Detach the sensor cable from the communication device 3 Disassemble the sensor depending on the assembly type MI The sensor is now disassembled 6 2 Disposing of the Sensor At the end of its service life dispose of the sensor in accordance with the applicable disposal regulations for electronic waste at the installation site at that time Alternatively send it back to SMA Solar Technology with shipping paid by the sender and labeled ZUR ENTSORGUNG for disposal 12 Windsensor lIEN101010 Installation Guide SMA Solar Technology AG 7 Technical data Mechanical data Technical data Height 160 mm Base diameter 50 mm Cup diameter 134 mm Weight 300 g Measured values Proportional frequency in relation to wind force 100 Hz at 40 m s