Home
N/C-20000 CPAP or VPAP Set-up Instructions
Contents
1. on page 1 Connect the barrel connector from Charge Controller to DC In Out Port A on Battery Connect the other end to Solar Panel as shown Figure 9 with the Authorized SunGuard Charge Controller Cable Keep Battery and Solar Panel connected charging whenever possible as it will take a up to 10 hours of direct sun light to fully charge a discharged Battery Battery Figure 9
2. DC power this WILL damage your ResMed CPAP see ResMed Manual A ResMed Converter or an Inverter optional accessories must be used When Using ResMed Converter Plug the car plug end of the ResMed Converter into the DC IN OUT Port B of Battery Figure 5 Plug the barrel connector end of the Converter into the ResMed CPAP OR When using an Inverter Make sure Inverter switch is in the OFF position the dot on the switch is up Figure 4 page 2 Plug the car plug end of the Inverter into the DC In Out Port of the Battery Turn the Inverter switch ON and confirm Green LED on inverter is on Plug the wall plug of the CPAP into the Inverter Turn CPAP Machine switch to ON ResMed CPAP rosvoa Converte DC In Out Port B Battery Converter ResMed CPAP Figure 5 H Shutting System Down l 8 21 2013 1 Power off the CPAP then turn off the inverter 2 Unplug the CPAP then the inverter Battery Reset no led lights after holding Test button for 30 seconds 1 If no lights come on this means the battery needs to be reset by having it plugged into one of the following power sources a A wall outlet using A C charger b An automobile using an inverter and the A C charger see cautions regarding using inverter c A second N C 20000 going from the D C out of the working battery to the D C in of other battery using the D C power cord with the J tip 2 Once connected to power source press and hold the Test but
3. Vehicle OPTIONAL EQUIPMENT A Using 2 Batteries to Power your CPAP Ti CPAP p Sy e 2 DC Power Cords included with Battery Packs e M Connector Tip included e Procedures All Brand CPAPs 1 Insert M Tip into end of DC Power Cord 1 2 Place the car plug end into the DC In Out Port B of Battery 1 3 Place the end with M Tip into the DC In Out Port A of Battery 2 e Procedures NON ResMed CPAPs Figure 6 Procedures for ResMed CPAPs Figures 7 amp 8 4 Place the appropriate Connector Tip 4 Make sure Inverter is turned OFF for your CPAP on the end of Cord 2 5 Insert car plug end of Inverter or ResMed 5 Connect DC Power Cord 2 car plug Converter into the DC In Out Port B of Battery 2 end into DC In Out Port B of Battery 2 5a Plug wall plug into Inverter 6 Connect Tipped end to CPAP 5b Turn inverter ON 7 Turn on your CPAP 6 Or if using Converter plug into ResMed CPAP 7 Turn on your CPAP DC Power see DC Power Cord1 MTipp ee N Cordi Connector Tips o SiG Batte gt ry Di T me Inverter pom DC Power ae 5b Cord 2 Swen E Figure 6 Figure 7 CPAP J DC Power Cordi ResMed Figure 8 B Charging the Battery using Solar Panel Optional Equipment 8 21 2013 1 2 J Included with the Solar Panel Solar Panel amp Charge Controller with Cable Fully charge Battery before leaving the Grid using the method outlined in Procedure C
4. METER End View of Battery F Powering a CPAP which can receive DC input directly from battery Figure 3 NOTE for all ResMed products please go to section G 1 Find the appropriate Connector Tip by comparing tips to the tip of your CPAP s AC charger Try the tip in your CPAP s charge port It should go in easily DO NOT force it 2 Place the appropriate Connector Tip on the end of DC Power cord 3 Connect the car plug end of the DC Power cord to the DC IN OUT Port B of the fully charged Battery 4 Connect the Connector Tip with Cable to your CPAP Novuscell Connector Tips Viidi NDC P A oad OS Carns Mobile CPAP Battery Pack Li ion DC Power Cord CPAP connected to Battery Figure 3 OR if you are using an Inverter some CPAPs only receive AC power from wall socket Figure 4 gt Inverter has an internal fan and will over heat if enclosed inside a carry bag must be allowed to breath 1 Make sure Inverter optional accessory switch is in the OFF position the dot on the switch is up 2 Plug the car plug end of the Inverter into the DC In Out Port of the Battery 3 Turn the Inverter switch ON and confirm Green LED on inverter is on 4 Plug the wall plug of the CPAP into the Inverter 5 Turn CPAP Machine switch to ON DC In Out Ports CPAP which requires AC input Figure 4 G your ResMed CPAP a e 1 2 3 4 2 DO NOT connect your ResMed CPAP directly to the Battery
5. Novuscell BA T T E R I E S dli i Instruction Manual for N C20000 Mobile CPAP Battery Pack Included in your package e Battery Bag e CPAP Lithium lon Battery e AC Charger 2 pcs e DC Power Cord amp Connector Tips e DC AC Inverter Optional Procedures A Read this Instruction Manual in its entirety prior to use Failure to follow these Procedures and observe the Cautions may result in any or all of the following Battery shut down Battery damage CPAP damage reduced run times shortened Battery life and voided Warranty 4 B Read your CPAP Manual carefully before assembling your system You are responsible for the application See Cautions on page 3 C Fully Charge the Battery Charging the Battery Using a Wall outlet see Cautions page 3 Figure 1 1 Connect 2 pieces of AC Charger 2 Connect the AC Charger wall plug to a wall outlet 3 Connect the AC Charger barrel connector to the DC IN OUT Port A of Battery 4 Charge until Charge Indicator Light on AC Charger is Green fully charged Red light charging This could take up to 8 hours if Battery is depleted gt DC In Out Port A AC Charger ate bs a lt O AC Line Charge Indicator Light Figure 1 charging the Battery Using an Inverter alternate method Figure 2 Make sure Inverter optional accessory switch is turned OFF j Start your vehicle vehicle must be running at all times to avoid draining your vehic
6. ecommend the use of the Humidifier with this Battery Although a humidifier can be used the usage times will be significantly lower than expected Multiple factors will affect the usage times including but not limited to device type pressure settings altitude use of the humidifier use of an Inverter or Converter 20 or more for each factor Use of a CPAP with more than 12V may cause Battery s internal circuitry to shut off to protect Battery from over run If the Battery stops functioning reconnect to the Battery s AC Charger to reset the internal circuitry Use ONLY the included factory approved AC Charger using any other charger will void your Warranty DO NOT rely on the LED lights as an indicator of full charge 4 lights 75 100 Meter is only a rough estimate of charge level Full charge is indicated by the GREEN light on the AC Charger Charging your Battery directly from your Vehicle s Power Socket using the DC Power Cord is NOT recommended as it could possibly damage the vehicle s electrical system If you wish to do this at your own risk follow these procedures 1 start the vehicle so the Power Socket will stabilize to approximately 13 volts 2 plug the Battery s DC Power Cord into the vehicle s Power Socket and 3 plug DC Power Cord into the Battery Reverse procedure to disconnect Vehicle must be running during charging vahide amy Power Cord M Tip Power _ are Socket DC In Out Port A Battery Start
7. le battery 3 Plug car plug end of Inverter into vehicle power socket 4 Turn inverter ON and note green run light 5 Connect the AC Charger wall plug to Inverter 6 Connect barrel connector end of AC Charger into DC IN OUT Port A of Battery 7 Charging is complete when indicator light is Green remove Inverter plug from socket see Cautions on page 3 Start Vehicle Vehicle Power 6f Et Socket DC In Out i Port A i a a AC Charger 3 RA Thverter i j Charge Indicator Light On Off By EA Switch E3 Figure 2 8 21 2013 D Using the Battery Test Button C See End View of Battery diagram below e Press the Test Button if any LED s come on continue as described below if no lights come on Hold the Test Button down for up to 30 seconds to turn Battery ON and view LED Power Meter e You should see one red or up to 4 LED lights come on if no lights come on please go to section I e Note the LED s will shut off after a few seconds however the battery will remain on e Indicator lights are a rough estimate of Battery power level See Cautions on page 3 E LED Power Meter E e When Low Power Alarm Light D is flashing Battery needs to be recharged However we recommend charging Battery when only 2 lights are visible e Press the Test Button C for 1 second to view the indicator lights on the Battery a A DC IN OUTPORT A B DC IN OUT PORT B C TEST BUTTON D LOW POWER ALARM LIGHT E LED POWER
8. ton until see the Led s light up the battery is now reset 4 CAUTIONS amp IMPORTANT NOTES VVVV V VVV WV v Vv Do not expose Battery to high heat i e leave in car this will reduce life cycles and or damage Battery Keep in dry environment electronic components will corrode with exposure to moisture For longer life store the Battery at 80 charge at a temperature of 50 75F discharge amp recharge every 90 days Do not attempt to disassemble the Battery Do not drop or crush CPAP Batteries are compatible with most makes amp models of CPAP machines however some are not able to receive DC power battery power and require the use of an optional DC to AC Inverter to complete the connection between the Battery and the CPAP Check your CPAP machine s user manual to determine if it can receive DC power An Inverter keeps the voltage from the battery constant because of this some DC compatible machines may get more run time with the optional Inverter even though they are able to receive DC power We suggest trying your connection with the Inverter amp then without the Inverter to determine which provides the best run time for DC compatible CPAPs only DO NOT leave Inverter plug connected to Vehicle Power Socket when Battery is fully charged OR when vehicle is not running Doing so will drain your CPAP Battery or your car battery It could also damage Battery and or power socket Manufacturers specifically DO NOT r
Download Pdf Manuals
Related Search
Related Contents
MicroBlaze Microcontroller Reference Design User Guide v1.5 Samsung Galaxy S5 Active Наръчник за потребителя(KK) Teledyne 3110 Oxygen Equipment User Manual 82600DM0100 VM FRアンダーリップ 取扱説明書 型 の 大画面映 6. Diagnóstico OBD II Darca Heritage Manual 明治機械製作所から5.5〜7.5KW新シ Manual_usuario_DielmoOpenLiDAR_2.0_BN6 SISTEMA DE AUDIO PORTATIL Boombox® NPB-260 Copyright © All rights reserved.