1. TOPCON INSTRUCTION MANUAL IMAGING TOTAL STATION GPT 7000i series PROGRAM MODE FOREWORD FOREWORD Thank you for purchasing the TOPCON Imaging Total Station GPT 7000i series For the best performance of the instruments please carefully read these instructions and keep them in a convenient location for future reference FOREWORD General Handling Precautions Before starting work or operation be sure to check that the instrument is functioning correctly with normal performance No responsibility TOPCON Corporation has no responsibility for loss of data stored in the memory in case unexpected accidents User 1 This product is for professional use only The user is required to be a qualified surveyor or have a good knowledge of surveying in order to understand the user and safety instructions before operating inspecting or adjusting 2 Wear the required protectors safety shoes helmet etc when operating Exceptions from Responsibility 1 The user of this product is expected to follow all operating instructions and make periodic checks of the product s performance 2 The manufacturer or its representatives assumes no responsibility for results of a faulty or intentional usage or misuse including any direct indirect consequential damage and loss of profits 3 The manufacturer or its representatives assumes no responsibility for consequential damage and loss of profits by any disaster an earthq
2. 35505 number of repetitions Mean Angle SEE 3 Diff Angle 0 00 00 1 Sight the 1st target RESET then press Meas button Horizontal angle will be released IMAGE NP 4 O Horizontal angle can be accumulated up to 99 times O clear all data press the RESET key 13 PROGRAM MODE Edge Abstraction Mode At the time of measurement this mode abstracts the edge and displays the coordinates of its points 1 Press the EDGE icon i 2 Collimate the target object Edge Extraction Measurement WIDE x0 50 3 Switch to the telescopic mode and press the MEAS key Measurement cannot be conducted unless you switch to the telescopic mode Telescopic numeric key 1 Wide angle numeric key 2 Following the completion of measurement the screen will become set Edge Extraction Measurement To release it click the CLEAR key TELE x1 00 Measurement results N E and Z will be displayed Edge Extraction Measurement these points indicating the abstracted edge If edge abstraction is unsuccessful a message to that effect will be displayed If you tap inside the frame the coordinates of the point tapped will be displayed You can also display the coordinates of any point when extraction has been successfully carried out TELE x1 00 10 669 E i 0 675 14 PROGRAM MODE Displayed Messages Message code Countermeasures Please Mode change to narrow a
3. REM icon 2 Select the YES button Remote Elevation Measurement Input Prism Height by Manual e yes Ono ee ET Prism Height 1 000 im 3 Input the Prism Height Example 1 000m 4 memorize the prism height press the SET key Remate Elevation Measurement 5 Press the YES key Input Prism Height by Manual ESC ti hu Storing the Current Refrector Height PROGRAM MODE 6 Collimate prism Remote Elevation Measurement Input Prism Height by Manual Or Ji es Prism Height 000 7 Press the Meas Prism REM Measure Prism 8 Press the SET key To measure the distance again press the RE TRY key WIDE x0 50 HD 2 128 rm Colimation OK olmation r i 9 Collimate target K Remote Elevation Measurement Input Prism Height by Manual Vertical angle VA and Vertical distance VD will a Yes C Ma be shown Prism Height f1 000 m SET 54 06 04 3 441 mi NP e HE PROGRAM MODE 2 Without prism height input 1 Press the REM icon 2 Select the NO button Remote Elevation Measurement Input Prism Height by Mana 3 Collimate prism 4 Press the Meas Prism key MEE _ 5 Pressthe SET key a b A 6 Collimate ground point G 7 Press the Meas Ground key WIDE x0 50 B 4725 Colimation OK 1 ser DI Exc Remote Elevation Measurement 9 Collimate target K Input Prism Height by Manual Vertical
4. angle VA and Vertical distance VD will Ow em be shown VA 4191345 VD 4 544 m NP e ung PROGRAM MODE Missing Line Measurement MLM The Missing Line Measurement program calculates the horizontal distance dHD slope distance dSD and elevation dVD between two target prisms The instruemt can accomplish this in two ways MLM Method A B A C Measurement is A B A C A D MLM Method A B B C Measurement is A B B C C D Prism A Prism B Instrument Prism C Example MLM Method A B A C Procedure of MLM Method A B B C is completely same as Method A B A C Method 1 Press the MLM icon 2 Select the A B A C button 3 Collimate prism A 4 Press the MEAS key Horizontal distance between the instrument and prism A will be shown Direction 10 PROGRAM MODE 5 Collimate and press the MEAS key corn reeset ill Horizontal distance between the instrument and NER BBC a prism B will be shown AvD den Direction And then the horizontal distance dHD relative E Line Measurement elevation dVD and slope distance dSD between prism A and B will be shown A B A C A B B C esc i m dHD 0 495 dvD 0 053 6 Press the IMAGE key dsD 0 498 Direction amar IMAGE Dan IMAGE RESET NP de A figure for drawing the sides of the image is IMAGE DISPLAY displayed WIDE x0 50 Miss
5. coordinate of occupied point C Example N coordinate 5 321m Unit wes im E E coordinate 8 345m Occupied PT E N 5 321 3 Input N and E coordinate of backsight point A E p 345 Backsight PT Pl 4 321 E 12 345 Example N coordinate 54 321m E coordinate 12 345m IMAGE At this time press the IMAGE key The image will be displayed NP e nag PROGRAM MODE 4 memorize the occupied point press the IMAGE DISPLAY SET OCC key 5 Press the YES key 6 Press the SET key M 5 321 PA 7 Collimate the backsight E 8 345 Backsight PT N 4 321 Ei 12 345 Occupied PT TER 8 Press the YES key Setting A Direction Angle The display returns to Program mode menu TELE x1 00 HR 40 00 4 40 Colimation OK loves D no PROGRAM MODE Remote Elevation Measurement REM The Remote Elevation program calculates the vertical distance height of a remote object relative to a prism and it s height from a ground point without a prism height When using a prism height the remote elevation measurement will start from the prism reference point If no prism height is used the remote elevation will start from any reference point in which the vertical angle is established In both procedures the reference point should be perpendicular to the remote object Target K Prism P VD Instrument Prism height 1 With prism height input 1 Press the
6. ct the menu by pressing panel icon Main menu STANDARD MEASUREMENT Press the PROG icon SETUP ADJUST PROG EXIT de Qua Program mode menu Repetition angle measurement Refer to Chapter Repetition Angle Measurement REP Missing line measurement Refer to Chapter Missing Line Measurement MLM Remote elevation measurement Refer to Chapter Remote Elevation Measurement REMY Setting a direction angle for backsight orientation Refer to Chapter Setting a Direction Angle for Backsight Orientation BS Edge abstraction mode Refer to Chapter Edge Abstraction Mode PROGRAM MODE Setting a Direction Angle for Backsight Orientation BS Entering the instrument and backsight coordinate values This program uses the input coordinate values of the occupied point instrument and backsight point to calculate the backsight orientation direction angle The occupied and backsight coordinate input display appears After the coordinate values are entered for both points the instrument calculates the backsight direction angle for orientation Also the occupied coordinate values are stored in memory The program does not store the backsight coordinate values in memory Backsight point Example Occupied point C N coordinate 5 321m E coordinate 8 345m Backsight point A N coordinate 54 321m E coordinate 12 345m 1 Press the BS icon Setting a Direction Angle 2 Input N and E
7. ing Line Measurement ITE 7 To measure the distance between points A and A 2 4 0 O 4 B B 0 C repeat procedure 5 m dHD 1227 dvb nos dsD 122 Direction 273 3352 O To confirm the previous data press the or gt key O To clear all data press the RESET key 11 PROGRAM MODE Repetition Angle Measurement REP Repetition Angle Measurement program calculates horizontal angles and shows the total angle Ht and the mean Hm of all the angles measured The program also keeps track of the amount of complete sets of horizontal angles measured Repetition Angle Measurement program can be done by horizontal angle right measurement mode 12 Repetition Angle Measurement H Angle 10 47 35 per 1 Press the REP icon 2 Collimate the first target A 3 Press the MEAS key Total Angle Vm Mean Angle Diff Angle Sight the 1st target A 4 then press Meas button Angle will be set ZERO IMAGE NP s ung Repetition Angle Measurement H Angle Total Angle Mean Angle Diff Angle Sight the 2nd target B 4 Collimate the second target B 5 Press the MEAS key then press Meas button Horizontal angle will be hold IMAGE NP amp HEN PROGRAM MODE The total of angle Ht and the mean of angle Repetition Angle Measurement Hm are shown H Angle 955 05 8 Tues 6 Repeat procedure 2 5 to measure the desired Total Angle
8. ngle Switch to telescopic display then conduct measure ment Corner detection has not been performed Edge extraction was unsuccessful but measurement was completed If you tap a point within the frame its coordinates will be displayed Can t change image after meas ls it all Following measurement the magnification and the right camera mode cannot be changed To change them press the CLEAR key Please specify within the limit Tap inside the frame O f message code still persist after attempting to clear them contact your local Topcon dealer or Topcon head office 15 PROGRAM MODE 16 IMAGING TOTAL STATION GPT 7000i series TOPCON CORPORATION 75 1 Hasunuma cho Itabashi ku Tokyo 174 8580 Japan Phone 3 3558 2520 Fax 3 3960 4214 www topcon co jp 64548 90020 GPT 7000i PROGRAM MODE
9. uake storms floods etc A fire accident or an act of a third party and or a usage any other usual conditions 4 The manufacturer or its representatives assumes no responsibility for any damage and loss of profits due to a change of data loss of data an interruption of business etc caused by using the product or an unusable product 5 The manufacturer or its representatives assumes no responsibility for any damage and loss of profits caused by usage except for explained in the user manual 6 The manufacturer or its representatives assumes no responsibility for damage caused by wrong movement or action due to connecting with other products FOREWORD Contents FOREWORD 1 General Handling Precautions ss due dw ques Gades EE PROP dia Les 2 iano ani 2 Exceptions from Responsibility 2 COMEM a N O TED 3 PROGRAM MODE 5 5232 xd xg ERE Bee NA RR dieu detente 4 Setting a Direction Angle for Backsight Orientation BS 5 Remote Elevation Measurement REM 7 Missing Line Measurement MLM 10 Repetition Angle Measurement REP 12 Edge ADS Macuon Mode pit quii qnd ED Maeda quise EA 14 Displayed Messages merito aras dad Neal i Re dad adan awe E 15 PROGRAM MODE PROGRAM MODE Sele
Download Pdf Manuals
Related Search
Related Contents
Targus SafeVu Westbrass D493244CH-07 Instructions / Assembly データベースサーバ統合で“攻め”のIT投資を Samsung PL80 Lietotāja rokasgrāmata Thecus Y.E.S Box N2100 iTunes Configuration Guide Descargar p550 Appareil photo numérique Manuel de l`utilisateur Porter-Cable PCE6430 Use and Care Manual Manuel d`utilisation - Migros Copyright © All rights reserved.