Home

User Manual

image

Contents

1. Symbol Byte Definition Note CMD 1 0x68 DAT1 1 0x06 Factory Reset DAT2 1 0 nouse DAT3 1 0 no use DAT4 1 0 no use Saving Mode Setting Symbol Byte Definition Note CMD 1 0x68 DAT1 1 0x08 Save 0x09 Call DAT2 1 1 24 1 24 saving modes DAT3 1 0 no use DAT4 1 0 no use Read write matrix information Symbol Byte Definition Note CMD 1 0x70 DAT1 1 0x10 Write 0x11 Read DAT2 1 Output way No 0 16 or ff DAT3 1 Input way No 0 16 DAT4 1 0 no use Index according to the output way when read the matrix information Input way 0 Output way 1 16 means close the corresponding output way Input way 0 Output way 0 means close all output ways Input way 0 Output way 0 Command is illegal no treatment Input way 1 16 Output way 1 16 means switch the corresponding way Input way 1 16 Output way ff means will switch input way to output way Read board software version number Symbol Byte Definition Note CMD 1 Ox6A Regulate other function gt DAT1 1 0x01 read Read software version number DAT2 1 0 255 Version number high DAT3 1 0 255 Version number low DAT4 1 0 Display mode high Low Such as 1 1 DXP D1616 User Manual 74 Read and write series number Symbol Byte Definition Note CMD 1 Ox6A Regulate other function gt DAT1 1 0x10 write 0x11 read se
2. Communication Toolbar Communication Toolbar includes three options as follows e am Open comm 8 Synchronization en 10101 Cascade Open Comm o After set the serial click to open the comm when open comm the icon e will turn to e and the red icon COMI Closed will turn to green icon COMI Opened DXP D1616 User Manual 44 5 Communication Software Guideline Software Operation 25 AVDEP Series Compact Router 2 0 4 6 Control Language Admin Help e z 8 l 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DESEEE SE EEE E Output 14 15 16 Al 1 2 3 4 5 6 7 8 9 10 11 12 13 Mo Mao HEE E HH Save User Mode Load User Mode Save 1 Save 2 Save 3 Save 4 Save 5 Save 6 Save 1 Save 2 Save 3 Save 4 Save 5 Save 6 Save 7 Save 8 Save 9 Gave 19 Save 11 Save 12 Save 13 Save 14 Save 15 Save 16 Save 17 Save 18 Save 19 Save 20 Save 21 Gave 2 Save 23 Save 24 Save 19 Save 20 Save 21 Save 22 Save 23 Save 24 MV 1 04 MA 0 SN 1234 100M 1 09 Click the e icon to close comm then the green icon COMI Opened will return to the red icon COMI Closed Synchronization When two devices work synchronously and user need to get the same operation both for DXP D1616 and windows control program click the synchronization icon g For example select input 2 output 3 in the front panel of DXP D1616 then cli
3. Logo Info Click the beside Logo ON OFF if need to set Logo Info Click the beside Custom Logo ON OFF to turn on the custom logo function Move the g or click Default to adjust the display time Adjust position by 3 up down arrow and input the information Click Set after setting Logo Info Display Time E Firm Info Postion 15 E Info 01234567890123456 Device Info Postion 5 E Info 01234567890123456 Set Factory Setup Click Factory Setup to reset to its factory settings Language Click the Language option and choose language version for example choose English click English the interface will be switched to English AVDEP Series Compact Ko Control P SEE Admin Help Chinese HH C English E Admin Advance debug is only done by engineer Please connect us for password DXP D1616 User Manual 43 5 Communication Software Guideline Software Operation Admin Password PP Eh Help Version explain Software version history About Display information of software About AVDXP Series Compact Router AR IAVYDXP Series Compact Router Version 2 0 4 6 Copyright C 2009 2014 RGBLink Co Ltd All Rights Reserved ddress 5603 604 Weiye Building Torch Hi Tech Industrial Development Zone Xiamen Fujian AGBlink erer y eee See EMaitrgblinkes gmail com pene ww rgblink com r
4. DXP D1616 User Manual 58 6 System Setup and Operations How to Set the Machine Address How to Set the Machine Address 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose MAC ADDR 3 Push the TAKE button to confirm Push any one of button 1 9 on output area to set the machine address Push the TAKE button to confirm after setting DXP D1616 User Manual 59 6 System Setup and Operations How to Realize Signal Auto Take How to Realize Signal Auto Take 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose AUTO TAKE 3 Push the TAKE button to confirm and enter to the auto take setting Push the NEXT button to choose ON or OFF then push the TAKE button to confirm System default the status is ON and when switch the signal user need not to push the TAKE button DXP D1616 User Manual 60 6 System Setup and Operations How to Lock the Front Panel How to Lock the Front Panel 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose LOCK 3 Push the TAKE button to confirm Push the NEXT button to choose ON or OFF then push the
5. 2048x1152 60 2560x812 60 2560x816 60 STMPE 480160 576150 720P50 60 1080150 60 1080P50 60 Signal Level TMDS pwl single pixel input 165MHz bandwidth Format Standard DVI 1 0 HDMI 1 3 DVI Output Number of Outputs 16 Connector Standard DVI I socket Signal Level TMDS pw 165MHz bandwidth Supported Resolution VESA 800x600 60 1024x768 60 1280x768 60 1280x1024 60 1360x768 60 1366x768 60 1400x1050 60 1440x900 60 1600x1200 60 1680x1050 60 1920x1080 60 1920x1200 60 2048x1152 60 2560x812 60 2560x816 60 STMPE 480160 576150 720P50 60 1080150 60 1080P50 60 Extras Communication RS232 Power Supply 85 264V 3 8A IEC 3 Working Environment 0 C 45 C Stored Environment 10 to 90 Product Warranty DXP D1616 3 years parts and labor warranty User Manual 68 B Contact Information dni Warranty All video products are designed and tested to the highest quality standard and backed by full 3 years parts and labor warranty Warranties are effective upon delivery date to customer and are non transferable RGBlink warranties are only valid to the original purchase owner Warranty related repairs include parts and labor but do not include faults resulting from user negligence special modification lighting strikes abuse drop crush and or other unusual damages The customer shall pay shipping charges when unit is
6. Navigation In 4 Use Acrobat Reader s bookmarks to navigate to the desired location All chapter files have the same bookmark structure for instant navigation to any section Please note e Extensive hyperlinks are provided within the chapters e Use Acrobat s Go to Previous View and Return to next View buttons to trace your complete navigational path e Use the Previous Page and Next Page buttons to go to the previous or next page within a file e Use Acrobat s extensive search capabilities such as the Find tool and Search Index tool to perform comprehensive searches as required Catalogue and Index Use the Table of Contents bookmarks to navigate a desired topic Click any item to instantly jump to that section of the guide You can also use the Index to jump to specific topics within a chapter Each page number in the Index is a hyperlink DXP D1616 User Manual 14 1 Brief Introduction Terms and Definitions Terms and Definitions The following terms and definitions are used throughout this Manual e ASCII American Standard for Information Interchange The standard code consisting of 7 bit coded characters 8 bits including parity check used to exchange information between data processing systems data communication systems and associated equipment The ASCII set contains control characters and graphic characters e Aspect ratio The relationship of the horizon
7. K 6500 K and 9000 K e Contrast ratio The radio of the high light output level divided by the low light output level In theory the contrast radio of the television system should be at least 100 1 if not 300 1 In reality there are several limitations In the CRT light from adjacent elements contaminate the area of each element Room ambient light will contaminate the light emitted from the CRT Well controlled viewing conditions should yield a practical contrast ratio of 30 1 to 50 1 e DVI Digital Visual Interface The digital video connectivity standard that was developed by DDWG Digital Display Work Group This connection standard offers two different connectors one with 24 pins that handles digital video signals only and one with 29 pins that handles both digital and analog video e EDID Extended Display Identification Data EDID is a data structure used to communicate video display information including native resolution and vertical interval refresh rate requirements to a source device The source device will then output the optimal video format for the display based on the provided EDID data ensuring proper video image quality This communication takes place over the DDC Display Data Channel e Ethernet A Local Area Network LAN standard officially known as IEEE 802 3 Ethernet and other LAN technologies are used for interconnecting computers printers workstations terminals serve
8. TAKE button to confirm Push the MENU button for 3 seconds to unlock panel DXP D1616 User Manual 61 6 System Setup and Operations How to Realize Hot Backup How to Realize Hot Backup 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose HOT BACKUP 3 Push the TAKE button to confirm and enter to hot backup function setting Push the NEXT button to choose ON or OFF then push the TAKE button to confirm Inputs 1 8 are any combination of backup it will recall another backup if one signal has problem The detailed parameters can be set on windows control program and invalid for button operation DXP D1616 User Manual 62 6 System Setup and Operations How to Save the Preset Input and Output Channel How to Save the Preset Input and Output Channel 1 Push the SAVE button on the front panel the button light is on At the same time some buttons 1 16 in output and input area are on and some flash Button is on can be saved and button flashes will be overwrite shown as follows 2 Choose the button on to save the LED screen will show save complete For example the button 3 on output area is on push the button the LED screen will show as follows 3 If choose the button flash the information saved before will be overwrite For example the button 1 on ou
9. e RS 232 An Electronic Industries Association EIA serial digital interface standard specifying the characteristics of the communication path between two devices using either DB 9 or DB 25 connectors This standard is used for relatively short range communication and does not specify balanced control lines RS 232 is a serial control standard with a set number of conductors data rate word length and type of connector to be used The standard specifies component connection standards with regard to the computer interface It is also called RS 232 C which is the third version of the RS 232 standard and is functionally identical to the CCITT V 24 standard e Saturation Chroma chroma gain The intensity of the color or the extent to which a given color in any image is free from white The less white in a color the truer the color or the greater its saturation On a display device the color control adjusts the saturation Not to be confused with the brightness saturation is the amount of pigment in a color and not the intensity Low saturation is like adding white to the color For example a low saturated red looks pink e Scaling A conversion of a video or computer graphic signal from a starting resolution to a new resolution Scaling from one resolution to another is typically done to optimize the signal for input to an image processor transmission path or to improve its quality when presented on a particular display
10. e SDI Serial Digital Interface The standard based on a 270 Mbps transfer rate This is a 10 bit scrambled polarity independent interface with common scrambling for both component ITU R 601 and composite digital video and four channels of embedded digital audio e Seamless Switching A feature found on many video switchers This feature causes the switcher to wait until the vertical interval to switch This avoids a glitch temporary scrambling which normally is seen DXP D1616 User Manual 18 1 Brief Introduction Terms and Definitions when switching between sources e SMPTE Society of Motion Picture and Television Engineers A global organization based in the United States that sets standards for base band visual communications This includes film as well as video and television standards e S video A composite video signal separated into the luma Y is for luma or black and white information brightness and the chroma C is an abbreviation for chroma or color information e Sync Synchronization In video sync is a means of controlling the timing of an event with respect to other events This is accomplished with timing pulses to insure that each step in a process occurs at the correct time For example horizontal sync determines exactly when to begin each horizontal scan line Vertical sync determines when the image is to be refreshed to start a new field or frame There are ma
11. 9 10 1 12 13 14 15 16 If need to close one output signal for example close output 3 click 0 in Input area then click 3 in Output area output 3 is closed and turn to original gray DXP D1616 User Manual 46 5 Communication Software Guideline Software Operation Input 0 1 2 3 4 5 6 7 8 9 10 1 12 13 14 15 16 Dutput All 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 If need to set one input to all outputs for example set input 1 to 16 outputs click input channel 1 in Input area then click All in Output area all outputs will switch to input 1 Input 0 1 2 3 4 5 6 if 8 9 10 11 12 13 IE 15 16 mina EE EHEHE E MA Output 11 12 13 14 15 16 All 1 2 3 4 5 6 7 8 9 10 papa Ea SA EE EE RE Save Load User Mode DXP D1616 provides 24 kinds of save modes User can save the parameters in Save User Mode area and load the saved parameters in Load User Mode area Save User Mode Load User Mode Information Toolbar lt shows the connect status software version and so on DXPY1616 o MV 1 04 M4 0 5N 1234 100M 1 09 DXP D1616 User Manual 47 5 Communication Software Guideline How to Connect Windows Control Program by RS232 Interface How to Connect Windows Control Program by RS232 Interface Firstly install the control software in your PC Connect one end of RS232 cable to the DXP D1616 and the other end to the serial port on the PC If there is no serial port in the PC it needs the S
12. current device status The first four screen show each output to the corresponding input channel The fifth screen shows the software version the sixth screen shows the serial number and the seventh screen shows the machine address Reset Enter to reset menus push any button to reset to its factory settings push the MENU button to exit LOGO Push the MENU button to enter to the menu items Push the MENU or NEXT button and choose lt LOGO gt push the NEXT button choose lt ON gt the device will show the LOGO Push the TAKE button to confirm DXP D1616 User Manual 31 4 Menu Orientation Menu EDID EDID is extended display identification data used to identify the input video display information When DXP D1616 is unable to detect the input signal but the input signal can be normal in the display enable the EDID function it will copy the EDID of output port to one or all input ports of the monitor Language User can choose Chinese or English according to their needs to operate the interface more quickly Cascade Push the MENU button to enter to the menu items Push the MENU or NEXT button and choose lt CASCADE gt user can check and set cascade Then push the TAKE button to confirm Mac Addr The machine address need to modify when use one windows control program and when use more windows control program user need to set up different machine address This function is cascade m
13. the MENU up arrow button or NEXT down arrow button and choose EDID 3 Push the TAKE button to confirm 4 Push any button on output area on the front panel for example choose 3 as the output channel 5 Push any button on Input area on the front panel for example choose 5 as the input channel E 6 Push the TAKE to confirm and the EDID copy finish Note DXP D1616 When set the EDID the output interface must be connected to monitors User Manual 56 6 System Setup and Operations How to Set the Language How to Set the Language 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose LANGUAGE 3 Push the TAKE button to confirm and enter to the language setting 4 Push the NEXT button to choose the language for example choose ENGLISH then push the TAKE button to confirm DXP D1616 User Manual 57 6 System Setup and Operations How to Realize Cascade Setting How to Realize Cascade Setting 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose CASCADE 3 Push the TAKE button to confirm and enter to the cascade setting Push the NEXT button to choose ON or OFF then push the TAKE button to confirm
14. 2 communication interface RS422 communication interface optional with outage protect function can read and store up to 100 user scenarios and special matching control software can in conjunction with computer remote control system or all kinds of distal control equipment such as center console system The system is equipped with multiple sets of serial instructions compatible with mainstream matrix of serial instruction set DXP D1616 User Manual 21 1 Brief Introduction Application Questions Application Questions RGBlink offers solutions to demand technical problems Any application questions or required further information please contact with our Customer Support Engineers Refer to Appendix B for contact details Monitor IA BE AVDSP Video Processor AVDSP FARS PC HS CP 2048 Control Interface a Pei HE RS232 Monitor LAS Video Wall HDTV Player PU HNL DXP D1616 User Manual 22 2 Hardware Orientation A In This Chapter This chapter provides detailed information about the DXP D1616 panel The following topics are discussed e DXP D1616 Front Panel e DKP D1616 Back Panel DXP D1616 User Manual 23 2 Hardware Orientation DXP D1616 Front Panel DXP D1616 Front Panel Brief introduction of DXP D1616 front panel as the following picture The front panel consist of LED screen indicator IR receiver and buttons the button is for control command input
15. 6 is unable to detect the input signal but the input signal can be normal in the display the use of EDID Study function will copy the output port is connected to the input port of the monitor of the EDID the device can identify the input signal Interface as shown EDID Study Qut Port E In Port CJ ALL In Port Comm Setup When control DXP D1616 via windows control program set the COM first For example set CommPort as COM1 which is checked from device manager set BoudRate to as 9600 Click OK after setting Comm Settings serial CommPort Com BaudRate 9600 DXP D1616 User Manual 41 5 Communication Software Guideline Software Operation Machine Addr The machine address need to modify when use one windows control program and when use more windows control program user need to set up different machine address Set from 1 click the up down arrow to select the machine address for example select 2 click Set to confirm Machine Addr Hot Backup Choose Hot Backup ON before set hot backup Inputs 1 8 are any combination of backup it will recall another backup if one signal has problem Group Number 2 ES Group Size Set Set C Hot Backup ON OFF Device Update Click to choose the file path then click Start to update the device Device Update DXP D1616 User Manual 42 5 Communication Software Guideline Software Operation
16. 7 Choose the upgrade program file path and click Start to begin to upgrade as shown File Path P Start usu 8 When loading progress is 100 it means loading successfully as shown below Or user need to load again FilePath Bati MCU YI O1AV Matrix MCU 20121210 V1 01 bin bin P Start 9 Restart the device and check whether it operates normally DXP D1616 User Manual 71 RGBlink D Serial Communication Protocol Serial protocol Baud rate 115200 BPS 1 bit start bit 1 bit stop bit No parity bit Protocol data format Sending data format as follows defined as shown in table 1 ADDR SN CMD DAT1 DAT2 DAT3 DAT4 CHKSUM Table 2 sends data format definition Symbol Byte Definition Note ADDR Address SN Used for transmission flow controlling CMD Command type DAT1 DAT2 DAT3 DAT4 CHKSUM a fos ee ee a O a a All protocol data Receiving data format as follows defined as shown in table 3 ADDR SN CMD DAT1 DAT2 DAT3 DAT4 CHKSUM Table 4 receiving data format definition Symbol Byte Definition Note ADDR Address Not used SN Used for transmission flow controlling CMD Command type DAT1 DAT2 DAT3 DAT4 CHKSUM i a A gt gt A r All protocol data C
17. DXP D1616 User Manual e Manual RGB RD UM D1616 E001 Revision V1 1 RGBlink DXP D1616 User Manual 1 DXP D1616 User Manual Thank you for choosing our products In order to allow you to learn how to use the DVI Matrix quickly we bring you the detailed user manual You can read the introduction and directions before using the DVI Matrix please read all the information we provide carefully to use our products correctly Copyright 2015 All rights are reserved by RGBlink This document is done independently by Xiamen RGBlink Science amp Technology Co LTD No part can be copied reproduced or translated without permission Notice RGBlink provides this manual as is without warranty of any kind no matter expressed or implied including but not limited to the implied warranties or merchantability and fitness for a particular purpose RGBlink may make improvements or changes to the products and the programs described in this publication at any time without notice This publication would contain technical inaccuracies or typographical errors Changes are periodically made to the information in this publication these changes are incorporated in new editions of this publication Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonabl
18. HKSUM ADDR SN CMD DAT1 DAT2 DAT3 DAT4 SN is used for flow controlling with beginning connection settings SN 0 each command PC send SN plus one The back command lower machine send should be consistent with the receiving SN command Lower machine should at least cache five receiving commands PC should well flow control DXP D1616 User Manual 72 according to SN sending command and SN receiving command The premise that PC sends the 5th command is already received the first command reply You can reduce the sending command and wait for receiving time by using SN flow control Frame format Sending and receiving frame format as follows including protocol data uses ASCII code such as 0 x02 means 0 x30 0x32 E Send IC ee ee E Receive IC 6 Go back following data when receive does not support command or error Symbol Byte Definition Note CMD 1 CMD DAT1 1 OxFF DAT2 1 OxFF DAT3 1 OxFF DAT4 1 OxFF Basic Setting Model Symbol Byte Definition Note CMD 1 0x68 DAT1 1 0x01 DAT2 1 Specification DAT3 1 Specification DAT4 1 0 no use DAT2 0x16 DAT3 0x16 Specification DXPV1616 DAT2 and DAT3 means matrix size if there is enable customers setting model DAT2 0x08 DAT3 0x08 Specification DXPV0808 Factory Reset DXP D1616 User Manual 73
19. L Phase Alternate Line A television standard in which the phase of the color carrier is alternated from line to line It takes four full pictures 8 fields for the color to horizontal phase relationship to return to the reference point This alternation helps cancel out phase errors For this reason the hue control is not needed on a PAL TV set PAL in many transmission forms is widely used in Western Europe Australia Africa the Middle East and Micronesia PAL uses 625 line 50 filed 25 fps composite color transmission system e PIP Picture in Picture A small picture within a larger picture created by scaling down one of the images to make it smaller Each picture requires a separate video source such as a camera VCR or computer Other forms of PIP displays include Picture by Picture PBP and Picture with Picture PWP which are commonly used with 16 9 aspect display devices PBP and PWP image formats require a DXP D1616 User Manual 17 1 Brief Introduction Terms and Definitions separate scaler for each video window e Polarity The positive and negative orientation of a signal Polarity usually refers to the direction or a level with respect to a reference e g positive sync polarity means that sync occurs when the signal is going in the positive direction e RJ 45 Registered Jack 45 A connector similar to a telephone connector that holds up to eight wires used for connecting Ethernet devices
20. ck the synchronization icon 8 the windows control program will synchronization to the current state Input 0 1 2 3 4 5 6 7 8 9 10 11 OM Ma E mon Dutput All 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 Moca HEH HE HH 1 14 15 16 2 13 EN mua Cascade When connect the second device with serial cable click the cascade icon DXP D1616 User Manual 45 5 Communication Software Guideline Software Operation qn E then it will search the cascade device and will display the machine address of one device on the page Left click 4 and enter to the widows control program page user can operate on this page Input and Output Signal Support 16 kinds of input signals and each input corresponding to different colors Input D 1 2 3 4 5 6 7 8 3 10 11 12 13 14 15 16 OM mata EE MON E MA Click input channel 1 in Input area and click output channel 1 on Output area then the color of output channel 1 will corresponding to the color of input channel 1 Input 0 1 2 3 4 5 6 7 8 9 10 11 E EET E nom Output All 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 14 15 16 yA 1G EN ma 1 User can also set one input to more outputs Click input channel 1 in Input area and click output channel 1 2 3 in Output area output 1 2 3 will output signal 1 and the color of output channel 1 2 3 will corresponding to the color of input channel 1 Input 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MU E HEEE E NA Output All 1 2 3 4 5 6 7 8
21. connector and has a horizontal scan frequency of 31 5 kHz and vertical frequency of 70 Hz Mode 1 2 and 60 Hz Mode 3 The signal is non interlaced in modes 1 2 and 3 and interlaced when using the 8514 A card 35 5 kHz 86 Hz in mode 4 It has a pixel by line resolution of 640x480 with a color palette of 16 bits and 256 000 colors e YCrCb Used to describe the color space for interlaced component video e YPbPr Used to describe the color space for progressive scan non interlaced component video DXP D1616 User Manual 20 1 Brief Introduction System Overview System Overview RGBlink strong technical strength determines the high quality of AVDXP series matrix switchers We choose the chips with best performance elaborate design for every way of switchers to ensure the high quality of switchers After rigorous testing 3G HD SD SDI video signal optical signal transmission rate are 2 97Gbps DVI switchers signal bandwidth is 2 5 GHz support HD digital signal input VGA switching signal bandwidth is 450 MHz 3 db support resolution of 2048x1536 60hz and 1024x768 120hz composite video bandwidth for 100 M 3 db fully meet various strict requirements and high quality occasions Products in this series are widely used in large screen projection display engineering electronic teaching command and control center multimedia meetings room etc Switches in this series are equipped with monochromatic LCD RS 23
22. e e 34 TAS CP 34 Software InstallatiON w ww wwmwmmmmmamamnamwa 35 Software OPEN 39 A fo 0 0 AEE NE ET NE 39 DXP D1616 User Manual 9 Communication Toolbar a 44 Input and Output Signal yaaa 46 save Load User Mode ada 47 Information Toolbar aa Rateenanaes cates 47 How to Connect Windows Control Program by RS232 Interface48 6 System Setup and OperatiONsS ooooocccccnononnncconccnonnccnnncnnns 50 MNS Chapter AAA A cee eden cela 50 How to Switch between Input and Output Channel 51 How to Switch One Input to all OutpU S lt s w w 53 How to Read Device Status ooooooccnnnccnnccnocnnonaconannnnnnnnconannnnnos 54 How to Set LOGO Display when Power On 55 How to Set the EDID ua TS 56 How to Set the Language resaltado 57 How to Realize Cascade SettidQ oooonconiccninconoconoccnonnconncnananannos 58 How to Set the Machine Address oooooonoconoccciccconcccocanancconccnnnanannos 59 How to Realize Signal Auto Take rnrnnnnnnnnrnnnrnonrnnenrnenrnenrnenvrneneenn 60 How to Lock the Front Panel oonnocnnccnonccnnccnncnnoccnonaconannnnnos 61 How to Realize Hot Backup ooocoocccocccoccccocococaconcconccnnnananccanccnnanannos 62 How to Save the Preset Input and Output Channel 63 How to Load the Saved Input and Output Channel 64 H
23. e RS 232 IN is the interface connecting serial communication interface of RS 232 control protocol can connect central control device such as CP 2048 RS 232 OUT is the serial communication interface of multiple devices cascading control can connect many sets of DXP devices Power and switch AC 85 264V 3 8A 50 60Hz IEC 3 DXP D1616 User Manual 27 RGBlink 3 Hardware Installation In This Chapter 301 00 This chapter provides comprehensive installation instruction for DXP D1616 hardware Following is the size of DXP D1616 for your reference 480 00 432 00 00000000 CI 000 00000000 ooo 00000000 0000 331 00 o GE GE GER GER gt AO D gt MD o 9 aa I AT AT AT de lt gt lt B gt SG MG lt gt MS MS SO o SS ME gt gt MS gt MS MD Po DXP D1616 User Manual 28 Safety Precautions For all DXP D1616 DVI Matrix installation procedures please observe the following important safety and handling rules to avoid damage to yourself and the equipment e To protect users from electric shock ensure that the chassis connects to earth via the ground wire provided in the AC power Cord e The AC Socket outlet should be installed near the equipment and be easily accessible Unpacking and Inspection Before opening DXP D1616 DVI Matrix shipping box inspect it for damage If you find any damage notify the shi
24. e protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed or used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area may cause harmful interference in which case the user will be responsible for DXP D1616 User Manual 2 correcting any interference Guarantee and Compensation RGBlink provides a guarantee related to perfect manufacturing as part of the legally stipulated terms of guarantee On receipt the purchaser must immediately inspect all delivered goods for damage incurred during transportation as well as for material and manufacturing faults Please complain to RGBlink by written notice The period of guarantee begins from the date of transfer of risks in the case of special systems and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of compliant RGBlink can repair the fault or provide a replacement at its own discretion within an appropriate period If this measure proves to be impossible or unsuccessful the purchaser can demand a reduction in the purchase price or cancellation of the contract All other claims in particular those relating to compensation for direct or indirect damage and also damage attributed to the operation of sof
25. ensity of video light produced on a screen without regard to color Sometimes called black level CAT 5 Category 5 Describes the network cabling standard that consists of four unshielded twisted pairs of copper wire terminated by RJ 45 connectors CAT 5 cabling supports data rates up to 100 Mbps CAT 5 is based on the EIA TIA 568 Commercial Building Telecommunications Wiring Standard e Color bars A standard test pattern of several basic colors white yellow cyan green magenta red blue and black as a reference for system alignment and testing In NTSC video the most commonly used color bars are the SMPTE standard color bars In PAL video the most commonly used color bars are eight full field bars In the DXP D1616 User Manual 15 1 Brief Introduction Terms and Definitions computer the most commonly used color bars are two rows of reversed color bars e Color burst In color TV systems a burst of sub carrier frequency located on the back porch of the composite video signal This serves as a color synchronizing signal to establish a frequency and phase reference for the chrome signal Color burst is 3 58 MHz for NTSC and 4 43 MHz for PAL e Color temperature The color quality expressed in degrees Kelvin K of a light source The higher the color temperature the bluer the light The lower the temperature the redder the light Benchmark color temperature for the A V industry includes 5000
26. erial to USB adapter Right click My Computer on the home screen of control PC Enter to Attribute Find Hardware option as following System Properties System Restore Automatic Updates Remote General Computer Name Hardware Advanced Device Manager 2 The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device A Driver Signing lets you make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Driver Signing Windows Update Hardware Profiles Drivers Lam Hardware profiles provide a way for you to set up and store ee different hardware configurations Hardware Profiles Click Device Manager on the left check the COM number as following COM1 is offered DXP D1616 User Manual 48 5 Communication Software Guideline How to Connect Windows Control Program by RS232 Interface Computer Management ml Fie Action view Window Help e amp DVD CD ROM Devices IDE ATA ATAPI controllers 8 PCMCIA adapters a Processors Se Disk drives wi Batteries Modems I Ports COM amp LPT gt BT Port COM 4 Smart card readers Remember the COM you are using and then run the control software find Communication option System default for the first time user have to click butto
27. int is loose you can replace the connecting line 3 Check if the output port is in accord with the controlled port 4 If not belong to above three circumstances maybe it is caused by host internal fault please send to professional for maintenance 5 If there is no display in LCD and no reaction for operation please check if the power input is good contacts 6 If the output image is disturbed maybe the input output devices without good ground 7 If there is obvious electrostatic when drawing or inserting audio and video interface maybe the power ground without good ground please ground with the right way otherwise it will easily damage the host and shorten the host life 8 LCD display is normal communication port has return code but no image output or no audio output e Maybe the AV interface is loose you can just plug it tightly e Maybe it is short connection you can just change it e Maybe wire is break you can just change it 9 If matrix panel button communication port can not be controlled maybe host internal is damaged please send to professional for maintenance DXP D1616 User Manual 67 RGBlink A Specification DVI Input Number of Inputs 16 Connector Standard DVI I socket Supported Resolution VESA 800x600060 1024x768 60 1280x768 60 1280x1024 60 1360x768 60 1366x768 60 1400x1050 60 1440x900 60 1600x1200 60 1680x1050 60 1920x1080 60 1920x1200 60
28. is now ready to configure AVDXP on this computer Click Next to begin configuration Click Back to change settings Click Cancel to exit DXP D1616 User Manual 37 5 Communication Software Guideline Software Installation Click Next to go on AVDEP InstallAware Wizard Installing AYDXP The program features you selected are being configured Ca Please wait while the Install ware Wizard installs AYDXP This may take several minutes Status AVDEP InstallAware Wizard Completing the InstallAware Wizard for AYDXP You have successfully completed the Install ware Wizard for AVDXP To close this wizard click Finish DXP D1616 User Manual 5 Communication Software Guideline Software Operation Software Operation Install communication which comes with the package of DXP D1616 device RGBlink Double click f icon from home screen and double click AVDXP to run the software DXP D1616 communication software interface as shown Zia AVDXP Series Compact Router 2 0 4 6 Control Language Admin Help E E 0 1 E 3 4 5 6 7 8 3 10 11 12 13 Ta 15 16 DAGE BEE E MA Dutput All 1 2 is 4 5 6 7 8 El 10 11 12 ve Ge TO Save User Mode Load User Mode mv 2227 MA 0 SH 100M 7 File Toolbar File Toolbar includes four options Control Language Admin and Help Control Control includes nine options In Port EQ Out Port Dr
29. iver EDID Study Com Setup Machine Addr Hot Backup Device Update Logo Info and Factory Setup interface as shown DXP D1616 User Manual 39 5 Communication Software Guideline Software Operation Language Admin Help In Port EQ Dut Port Driver EDID Study Comm Setup Machine Addr Hot Backup 3 4 poto MIN Factory Setup In port EQ If extend the DVI input cable user need to adjust the EQ value of compensation to ensure signal receiving Select All all the inputs will be set to the same value User can read the EQ after write it Select Write to write the EQ and select Read to read it InPort EQ In Port E Ca Ea p E Out port Driver If extend the DVI input cable user need to adjust the out port driver value of compensation to ensure signal transmission Select All all the inputs will be set to the same value Select Write to write the EQ and select Read to read it Out Port Driver Driver EQ and Out Driver values table DXP D1616 User Manual 40 5 Communication Software Guideline Software Operation Cable length m EQ Values DRIVE Values Input cable Out cable 1 5 1 5 0 5 0 3 1 5 3 0 5 0 3 1 5 16 5 0 4 1 3 1 5 30 0 5 1 3 3 1 5 0 1 0 3 3 3 0 4 0 3 3 16 5 0 1 1 3 3 30 0 4 1 3 EDID study EDID is extended display identification data used to identify the input video display information When DXP D161
30. k Science amp Technology Co Ltd Headquarter S603 604 Weiye Building Torch Hi Tech Industrial Development Zone Xiamen Fujian Province P R C Shenzhen office Floor 11 A1 Building Baiwang R amp D Building Shahe West Road Xili Town Nanshan District Shezhen Guangdong Province P R C Beijing office No 2702 Sino Light Building Tower B Wang Jing East Road Chaoyang District Beijing P R C Shanghai office East Building F2 No 88 Qinjiang Road Shanghai P R C Tel 86 592 5771197 Fax 86 592 5771202 Customer Hotline 4008 592 315 Websites htip Awww rgblink com httip Awww rgblink cn e E mail sales rgblink com DXP D1616 User Manual Safe Operation Summary The general safety information in this summary is for operating personnel Do Not Remove Covers or Panels There are no user serviceable parts within the unit Removal of the top panel will expose dangerous voltages To avoid personal injury do not remove the top panel Do not operate the unit without the panel installed Use the Proper Properly This product is intended to operate from a power source that will not apply more than 230 volts rms between the supply conductors or between both supply conductor and ground A protective ground connection by way of grounding conductor in the power cord is essential for safe operation Ground the Product Properly This product is grounded through the grounding conductor of the power cord To avoid elect
31. lows 1 If choose AUTO TAKE ON push any button on output area in the front panel for example choose 5 as the output channel Then push any button on Input area in the front panel for example choose 3 as the input channel the signal of output channel 5 will be switched to the signal of input 3 2 If choose AUTO TAKE OFF push any button on output area on the front panel for example choose 5 as the output channel Then push any button on input area on the front panel for example choose 3 as the input channel After setting push the TAKE button to confirm DXP D1616 User Manual 51 6 System Setup and Operations How to Switch between Input and Output Channel Note Input channel The signal that will be switched to output channel Output chamnel The signal that connected to display device The number 1 16 means channel 1 16 DXP D1616 User Manual 52 6 System Setup and Operations How to Switch One Input to all Outputs How to Switch One Input to all Outputs 1 If choose AUTO TAKE ON push the ALL button on the front panel Then push any button on input area on the front panel for example choose 3 as the input channel all the signal of output channel will be switched to the signal of input 3 2 If choose AUTO TAKE OFF push the ALL button on the front panel Then push any button on Input area in the front panel for exa
32. mple choose 3 as the input channel Push the TAKE button to confirm all the signal of output channel will be switched to the signal of input 3 DXP D1616 User Manual 53 6 System Setup and Operations How to Read Device Status How to Read Device Status 1 Push the MENU button on the front panel and enter to the menu items 2 System default STATUS option if it is not selected push the MENU up arrow button or NEXT down arrow button and choose STATUS 3 Push the TAKE button to confirm user can view the current device status The first four screen show each output to the corresponding input channel The fifth screen shows the software version the sixth screen shows the serial number and the seventh screen shows the mac address DXP D1616 User Manual 54 6 System Setup and Operations How to Set LOGO Display when Power on How to Set LOGO Display when Power on 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose LOGO 3 Push the TAKE button to confirm and enter to LOGO setting push the NEXT button to choose ON or OFF then push the TAKE button to confirm DXP D1616 User Manual 55 6 System Setup and Operations How to Set the EDID How to Set the EDID 1 Push the MENU button on the front panel and enter to the menu items 2 Push
33. munication software The following topics are discussed e Software Installation e Software Operation e Howto Connect Windows Control Program by RS232 Interface DXP D1616 User Manual 34 5 Communication Software Guideline Software Installation Software Installation DXP D1616 video processor is very easy to be configured with user friendly communication software for edit and display Double click Next to next dialog AYDXP InstallAware Wizard Welcome to the InstallAware Wizard for AWDXP The Install4ware Wizard will install AVDXP on your computer WARNING This program is protected by copyright law and international treaties To continue click Next Cancel And in next dialog is the user agreement of the software click Agree to go on AVDEP InstallAware Vizard License Agreement Please carefully read the following license agreement IMPORTANT PLEASE READ Terms and Conditions of RGBlink Product Support Software License Agreement This RGBlink Product Support Software License Agreement this Agreement is effective as of the date the Software is obtained from RGBlink the Effective Date and is entered into by and between RGBlink Corporation 5603 Weiye Building Torch Hi Tech Industrial Development Zone Xiamen Fujian Province P R C RGBlink and You 1 DEFINITIONS You Your or Licensee means the individual or company who has or will download use and o
34. n as following Comm Settings Serial CommPort Coml v BaudRate 9600 v Check and tap Serial Serial Port for example is COM1 which is checked from device manager Set DXP D1616 Boud Rate to be 9600 Click Confirm after setting Click e open serial check if COM icon is on the bottom right corner when there is the prompt green showing on the software it means the communication is ok and you can use the software to control the device now DXP D1616 User Manual 49 RGBlink 6 System Setup and Operations In This Chapter This chapter focuses on system setup and operation mainly including the following contents e How to Switch between Input and Output Channel e How to Switch One input to all Outputs e Howto Read Device Status e Howto Set LOGO Display when Power on e How to Set the EDID e Howto Setthe Language e Howto Realize Cascade Setting e Howto Set the Machine Address e Howto Realize Signal Auto Take e How to Lock the Front Panel e Howto Realize Hot Backup e How to Save the Preset Input and Output Channel e How to Load the Saved Input and Output Channel e How to Reset the Factory Settings DXP D1616 User Manual 50 6 System Setup and Operations How to Switch between Input and Output Channel How to Switch between Input and Output Channel User can switch the signals between input and output channel by front panel buttons of DXP D1616 specific operations are as fol
35. nu tree 3 Change the windows control program Format Time ECO Description Principal 1 0 2013 11 21 0000 Release Peter 1 0 2015 01 20 0001 1 Change the front and back panel Vira DXP D1616 User Manual N RGBlink CONTENT CONTENT serviran adds 8 1 Brief INTO UCI aversjon 12 Chapter Structure sa 13 ML Puso andando 14 Terms and Definitions isc ii tia 15 System Overview rrrnrrrnrnannennnensnrnnnvennnensnrvnnrnsnnensnrsnnrennnenensnsnssennee 21 Application QUESTIONS vasca anan 22 2 Hardware OrientatioN cmononcccnnocoonnnccnnnonannnccnnncnanoccnonoonos 23 In This Pr 23 DAP D1616 Front Panel sora 24 ECD Panela IA AA AA dst AA AA AA 24 A AAA 24 AR REE dol 25 FUNGUO BUD N spore 25 DXP D1616 Back Panel necia roca 27 3 Hardware Installation susi dd 28 ao EE 28 Safety Precautions cn riada 29 Unpacking and Inspection arnranvnonrnonvrnrnrnenrnrnrnrerrnenrnenrnerrreensenn 29 DXP D1616 User Manual 8 SAA aan 29 4 Menu Orientation micocii inncacicinnccinncacincc nina ncicinnn caricias 30 TAS CNA do 30 MENO asa SNS RESIDES 31 DIALUS si Sa 31 HE ve 31 OO atric tera A beatin e WAA WA IA WA IAA KIKA NA 31 D NE ET EE ENER 32 Language a atest eana EEEE ayn eh cle i Nae ka 32 Cascade EE ese MA tava theives Aun tes tet she arias a lees 32 Mac Addi ara A 32 KN 32 A A 32 A tsecaks sae tated cha Uses A TT 33 WAA O 33 ME NN 33 5 Communication Software Guidelin
36. ny other types of sync in video system Also known as sync signal or sync pulse e TCP IP Transmission Control Protocol Internet Protocol The communication protocol of the Internet Computers and devices with direct access to the Internet are provided with a copy of the TCP IP program to allow them to send and receive information in an understandable form e USB Universal Serial Bus USB was developed by seven PC and telecom industry leaders Compaq DEC IBM Intel Microsoft NEC and Northern Telecom The goal was easy plug and play expansion outside the box requiring no additional circuit cards Up to 127 external computer devices may be added through a USB hub which may be conveniently located in a keyboard or monitor USB devices can be attached or detached without removing computer power The number of devices being designed for USB continues to grow from keyboards mice and printers to scanners digital cameras and ZIP drives e VESA Video Electronics Standards Association A nonprofit number organization dedicated to facilitating and promoting personal computer graphics through improved standards for the benefit of the end user www vesa org e VGA Video Graphics Array Introduced by IBM in 1987 VGA is an DXP D1616 User Manual 19 1 Brief Introduction Terms and Definitions analog signal with TTL level separate horizontal and vertical sync The video outputs to a 15 pin HD
37. ow to Reset the Factory SettiMgS oconccnncconoconoccniccconnanananannos 65 7 Common Questions and Solutions cooccccmomommmmmsmom o 66 DXP D1616 User Manual 10 IA thischapt r a 66 A Specification iii i 68 B Contact INfOrmatl OM viscosidad 69 C Software Upgrade comodidades 70 MCU Program Ud iia 70 D Serial Communication Protocol ooocccooncnnnnnncnnnonnnnnonns 72 DXP D1616 User Manual 11 1 Brief Introduction dla This chapter is designed to introduce you to the DXP D1616 User Manual It covers e Chapter Structure e Manual Usage e Terms and Definitions e System Overview e Application Questions DXP D1616 User Manual 12 1 Brief Introduction Chapter Structure Chapter Structure The following chapters provide instructions for all aspects of DXP D1616 operations Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Appendix A Appendix B Appendix C Appendix D DXP D1616 Brief Introduction Hardware Orientation Hardware Installation Menu Orientation Communication Software Guideline System Setup and Operations Common Questions and Solution Specification Contact Information Software Upgrade Serial Communication Protocol User Manual 13 1 Brief Introduction Manual Usage Manual Usage Following are important tips for streamlining your use of this User Manual in its electronic PDF form
38. pping carrier immediately for all claims adjustments As you open the box compare its contents against the packing slip If you find any shortages contact your sales representative Once you have removed all the components from their packaging and checked that all the listed components are present visually inspect the system to ensure there was no damage during shipping If there is damage notify the shipping carrier immediately for all claims adjustments Site Preparation The environment in which you install your DXP D1616 should be clean properly lit free from static and have adequate power ventilation and space for all components DXP D1616 User Manual 29 4 Menu Orientation dl In This Chapter This chapter describes all DXP D1616 processor menus including how they are accessed the functions that are available and descriptions of each menu tree in block diagram format The following topics are discussed e MENU e Status e Reset e LOGO e EDID e Language e Cascade e Mac Addr Lock e Hot Backup Auto Take Work Time e Mute DXP D1616 User Manual 30 4 Menu Orientation Menu MENU Push the MENU button to enter the menu items shown as below Push the MENU up arrow reuse button and NEXT down arrow button to select menu items Push the TAKE button to enter corresponding setting or view the menu STATUS MAC ADDR Status User can view the
39. r distribute the RGBlink Product Support Software and who is being licensed to use the Software We Us or RGBlink means RGBlink Corporation an China corporation The Program or the Software means the software package that was or will be downloaded or obtained from RGBlink and which may be comprised of a setup program self extracting v DXP D1616 User Manual 35 5 Communication Software Guideline Software Installation AYDXP InstallAware Wizard Customer Registration Please enter information on yourself k user Install yware User can select Change to choose the DXP D1616 install software AYDXP InstallAware Wizard Destination Folder Select folder where setup will install files Installaware DXP D1616 User Manual 5 Communication Software Guideline Software Installation Click Next to go on AYDXP InstallAware Wizard Select Program Folder Select the location where you would like to create new shortcuts Setup will add program shortcuts to the Program Folder listed below You may type anew folder name or accept the suggested name Click Next to continue Program Folder AYDXP Install this application For Anyone who uses this computer all users Only for me current user InstallAware Click Next to go on AYDXP InstallAware Wizard Completing the InstallAware Wizard for AYDXP The Install4ware Wizard
40. r example When switch off the AUTO TAKE function push the ALL gt 5 Enter button it will distribute the input of channel 5 to all outputs SAVE Save button save all current switching channels and current states the buttons 1 16 in output channel correspond to save 1 16 and the buttons 1 16 in input channel correspond to save 17 32 a total of 32 kinds of saving modes For example Push the SAVE button then push the 6 button in output channel the current state will be saved to SAVE 6 Note If power fails suddenly the device will automatically save to the current using mode and do not need reset when power on LOAD Load button load all the saved modes the buttons 1 16 in DXP D1616 User Manual 25 2 Hardware Orientation DXP D1616 Front Panel output channel correspond to save 1 16 and the buttons 1 16 in input channel correspond to save 17 32 a total of 32 kinds of saving modes For example Push the LOAD button then push the 3 button in output channel user can load SAVE 3 DXP D1616 User Manual 26 2 Hardware Orientation DXP D1616 Back Panel DXP D1616 Back Panel Brief introduction of DXP D1616 back panel as the following picture The port marked with DVI D INPUTS is input ports connecting the signal source and video signal from laptop The port marked with DVI D OUTPUTS is output ports connecting monitor projectors and other display devic
41. returned for repair Headquarter S603 604 Weiye Building Torch Hi Tech Industrial Development Zone Xiamen Fujian Province P R C Tel 86 592 5771197 Fax 86 592 5771202 Customer Hotline 4008 592 315 Websites http www rgblink com http www rgblink cn e E mail support rgblink com DXP D1616 User Manual 69 RGBlink C Software Upgrade MCU Program Upgrade 1 Connect RS232 interface to the computer with a RS232 cable That is connect the RS 232 IN port of DXP D1616 to the RS232 COM port of the computer 2 Power on AVDXP exe 3 Double click t and open the software the interface as shown Za AVDEP Series Compact Router 2 0 2 4 WSAD Language Admin Help In Fort EQ Out Port Driver EDID Study Comm Setup Machine Addr USART Set 3 4 5 6 7 Device Update E mH im E Logo Info Factory Setup 4 Comm Setup choose the CommPort and set BaudRate for example choose Com1 and set BaudRate as 115200 click OK after setting Comm Settings Serial CommPort Com1 v BaudRate DXP D1616 User Manual 70 5 Open comm ej If the status shows green communication is ok and user can use the software to control the device DXPV1616 4 it means the 6 Choose the Device Update the interface as shown e AYDXP Series Compact Ro MENS Language Admin Help EDID Study Comm Setup Machine Addr USART Set Device Update 3 4 vono M Factory Setup
42. rical shock plug the power cord into a properly wired receptacle before connecting to the product input or output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Use the Proper Power Cord Use only the power cord and connector specified for your product Use only a power cord that is in good condition Refer cord and connector changes to qualified service personnel Use the Proper Fuse To avoid fire hazard use only the fuse having identical type voltage rating and current rating characteristics Refer fuse replacement to qualified service personnel Do Not Operate in Explosive Dangerous Atmospheres To avoid explosion do not operate this product in an explosive atmosphere DXP D1616 User Manual 5 Terms and Equipment Mark in This Manual WARNING Highlight an operating procedure practice condition statement etc which if not strictly observed could result in injury or death of personnel Note Highlights an essential operating procedure condition or statement CAUTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance DXP D1616 User Manual 6 Amendment Record The table below lists the changes to the DVI Matrix User Manual 2 Change the me
43. ries number DAT2 1 0 255 Series number high DAT3 1 0 255 Series number low DAT4 1 0 For example high for 0x12 low for 0x34 then series number is 1234 Read and write communication address not IP address Symbol Byte Definition Note CMD 1 Ox6A Regulate other function DAT1 1 Ox20 write Ox21 read Local address DAT2 1 0 99 Local address 0 means broadcast address DAT3 1 O no use DAT4 1 O no use Local address is default for 0 LOGO Display Parameters Setting Symbol Byte Definition Note CMD 1 0x68 DAT1 1 Oxf3 DAT2 1 1 0 Open Close LOGO display DAT3 1 1 0 Display Cancel display customer LOGO DAT4 1 1 10 boot LOGO display time second DXP D1616 User Manual 75 Common communication commands lt T addr sn cmd data1 data data3 data4 cs gt cs addr sn cmd data1 data2 data3 data4 lt T0001701002020085 gt switch input2 gt output2 lt T0001701003020086 gt switch input2 gt output3 lt T0001701004030088 gt switch input3 gt output4 lt T000170100e0a0099 gt switch input10 gt output14 lt T000170100e00008F gt close output way14 lt T0001 701 0ff040084 gt switch input4 gt all outputs lt T0001701106000088 gt Read input channel that output way6 correspond to lt F00017011060d0095 gt Back input13 gt output6 Note Compatible with Extron matrix MVX 1616 VGA A agreement DXP D1616 User Manual 76
44. rs etc within the same building or campus Ethernet operates over twisted pair and over coaxial cable at speeds starting at 10Mbps For LAN interconnectivity Ethernet is physical link and data link protocol reflecting the two lowest layers of the OSI Reference Model e Frame In interlaced video a frame is one complete picture video frame is made up of two fields or two sets of interlaced lines In a film a frame is one still picture of a series that makes up a motion picture e Gamma The light output of a CRT is not linear with respect to the voltage input The difference between what you should have and what is actually output is known as gamma e HDMI High Definition Multimedia Interface An interface used primarily in consumer electronics for the transmission of DXP D1616 User Manual 16 1 Brief Introduction Terms and Definitions uncompressed high definition video up to 8 channels of audio and control signals over a single cable HDMI is the de facto standard for HDTV displays Blu ray Disc players and other HDTV electronics Introduced in 2003 the HDMI specification has gone through several revisions e HDSDI The high definition version of SDI specified in SMPTE 292M This signal standard transmits audio and video with 10 bit depth and 4 2 2 color quantization over a single coaxial cable with a data rate of 1 485 Gbit second Multiple video resolutions exist including progressive 1280
45. stions and Solutions In this chapter This chapter mainly introduces common fault problems and solutions of the video processor specific content as follows 1 When there is ghost in matrix peripheral display device images for example the projector has ghost generally it is not caused by the host Maybe the projector is not adjusted probably or the wire quality is not standard adjusting the projector button or replacing the wire is needed Maybe the wire is too long and cause signal attenuation adding a long wire drive is needed e Maybe hybrid installation with the 220V high voltage 2 When there is color loss or no video signal output maybe it is caused by poor contact of video interface or break 3 When COM generally refers to computer serial port can not control the matrix check if the communication port that controls software set is corresponding to device serial port Check if the computer communication port is in good condition 4 No corresponding image output when matrix switching 1 Check if the corresponding input has any signals or test with oscilloscope or multimeter If there is no signal input may be the input connection is broken or joint is loose you can replace the connecting line 2 Check if the corresponding output end has any signals or test with oscilloscope or multimeter if there is no signal output may be the input DXP D1616 User Manual 66 connections is broken or jo
46. tal dimension to the vertical dimension of an image In viewing screens standard TV is 4 3 or 1 33 1 HDTV is 16 9 or 1 78 1 Sometimes the 1 is implicit making TV 1 33 and HDTV 1 78 e AV Audio visual or audio video e A Background is an unscaled source typically originating from a computer background source appears at the system s lowest priority visually in back of all other sources e Baudrate Named of J M E Baudot the inventor of the Baudot telegraph code The number of the electrical oscillations per second called baud rate Related to but not the same as transfer rate in bits per second bps e Blackburst The video waveform without the video elements It includes the vertical sync horizontal sync and the chroma burst information Blackburst is used to synchronize video equipment to align the video output One signal is normally used to set up an entire video system or facility Sometimes it is called House sync e BNC Bayonet Neill Concel man A cable connector used extensively in television and named for its inventors A cylindrical bayonet connector that operates with a twist locking motion To make the connection align the two curved grooves in the collar of the male connector with the two projections on the outside of the female collar push and twist This allows the connector to lock into place without tools e Brightness Usually refers to the amount or int
47. ting the LED screen is composed of 128 16 points and used to display the operation and running state the indicator shows the operating status LCD Panel Used to display the current status and prompting message Plug into the power cord and push the power button to ON the LCD module on the front panel will show RGBLINK and go into self verification For the first setup it is default for factory setting With front panel keyboard user can operate DXP D1616 through the menus on LCD panel DXP D1616 front panel as shown in figure H Indicator Power The red power indicator is on when there is power supply Mode When switch audio and image at the same time the yellow mode DXP D1616 User Manual 24 2 Hardware Orientation DXP D1616 Front Panel indicator is on DXP D1616 V1 1 can not support this function Com When connect device for cascade the green Com indicator is on IR Receiver Can receive the infrared signal Function Button 1 16 Digital button Selection button for input and output channel used to set video signal input and output channel also can be used to number choice of save or call saving modes MENU Menu and up arrow button Push the button to enter into the menu items In menu state push the menu to exit the current state to the previous state NEXT Down arrow button TAKE Confirm button ALL Distributor selection button it will output one input to all outputs Fo
48. tput area is on push the button the LED screen will show as follows Push the TAKE button to confirm and push MENU button to cancel 4 Push the MENU to exit the save state or push the SAVE button the light is off and exit the save state Note The buttons 1 16 on output area corresponding to save 1 16 and the buttons 1 16 on output area corresponding to save 17 32 DXP D1616 User Manual 63 6 System Setup and Operations How to Load the Saved Input and Output Channel How to Load the Saved Input and Output Channel 1 Push the LOAD button on the front panel the button light is on At the same time some buttons 1 16 in output and input area are on and some flash Button on is ready for recall and button flashes means just recall shown as follows 2 Push the button on to recall 3 Push the MENU button to exit the load state or push the LOAD button the button light is off and exit the load state DXP D1616 User Manual 64 6 System Setup and Operations How to Reset the Factory Settings How to Reset the Factory Settings 1 Push the MENU button on the front panel and enter to the menu items 2 Push the MENU up arrow button or NEXT down arrow button and choose RESET 3 Push the TAKE button to confirm 4 Push any key to reset factory settings and push MENU button to exit DXP D1616 User Manual 65 RGBlink 7 Common Que
49. tware as well as to other service provided by RGBlink being a component of the system or independent service will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence or part of RGBlink If the purchaser or a third party carries out modifications or repairs on goods delivered by RGBlink or if the goods are handled incorrectly in particular if the systems are commissioned operated incorrectly or if after the transfer of risks the goods are subject to influences not agreed upon in the contract all guarantee claims of the purchaser will be rendered invalid Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by RGBlink either The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with the customer Trademark Brand and product names mentioned in this manual may be trademarks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufactures DXP D1616 User Manual 3 Company Address RGBlink Xiamen RGBlin
50. ultiple machines of different address and controlled by windows control program Lock In order to avoid the wrong operations user can lock front panel Push MENU key for 3 seconds to unlock panel Hot Backup User can turn on or off the hot backup function push the TAKE button to DXP D1616 User Manual 32 4 Menu Orientation Menu confirm after set Inputs 1 8 are any combination of backup it will recall another backup if one signal has problem The detailed parameters can be set on windows control program and invalid for button operation Auto Take Push the MENU button to enter to the menu items Push the MENU or NEXT button and choose lt AUTO TAKE gt push the NEXT button to turn on or off the auto take function push the TAKE button to confirm System default turn on this function and user need not to push the TAKE button to confirm when switch the signal Work Time Push the MENU button to enter to the menu items Push the MENU or NEXT button and choose lt WORK TIME gt user can view the boot times and total time Mute Push the MENU button to enter to the menu items Push the MENU or NEXT button and choose lt MUTE gt user can turn on or off the mute function After setting push the TAKE button to confirm DXP D1616 User Manual 33 RGBlink 5 Communication Software Guideline In This Chapter This chapter provides detailed information about the control com
51. x720 and interlaced 1920x1080 resolutions Up to 32 audio signals are carried in the ancillary data e JPEG Joint photographic Expects Group Commonly used method of lost compression for photographic images using a discreet cosine transfer function The degree of compression can be adjusted allowing a selectable tradeoff between storage size and image quality JPEG typically achieves 10 1 compression with little perceptible loss in image quality Produces blocking artifacts e MPEG Motion Picture Expect Group A standard committee under the auspices of the International Standards Organization working on algorithm standards that allow digital compression storage and transmission of moving image information such as motion video CD quality audio and control data at CD ROM bandwidth The MPEG algorithm provides inter frame compression of video images and can have an effective compression rate of 100 1 to 200 1 e NTSC The color video standard used in North America and some other parts of the world created by the National Television Standards Committee in the 1950s A color signal must be compatible with black and white TV sets NTSC utilizes an interlaced video signals 525 lines of resolution with a refresh rate of 60 fields per second 60 Hz Each frame is comprised of two fields of 262 5 lines each running atan effective rate of 30 frames per second e Operator Refers to the person who uses the system e PA

Download Pdf Manuals