Home

User manual KSIO 9~24K.cdr

image

Contents

1. Using remote control section models only room very well Air filter is blocked Clean the air filter while air flowing Doors or Windows are open Close the doors or windows lout from the air conditioner Air inlet or outlet of indoor or outdoor unit has been blocked Clear obstructions away first then restart the unit Compressor 3 minutes protection has been activated Wait If the trouble has not been corrected please contact a local dealer or the nearest customer service center Be sure to inform them of the detailed malfunctions and unit model number Notes Do not attempt to repair the unit yourself Always consult an authorized service provider o Kimaire The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2014 Klimaire Products Inc 2190 NW 89 Place Doral FL 33172 USA Tel 305 593 8358 Fax 305 675 2212 www klimaire com sales klimaire com The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details
2. OPERATING INSTRUCTIONS eo a O Special functions Refrigerant Leakage Detection With this new technology the dipsplay area will appear EC and the indication lamps continue flashing when the outdoor unit detects refrigerant leakage Louver Angle Memory Function optional Within the scope of safety angle it will memorize the open angle of horizontal louver If it exceeds it will memorize the boundry of safety angle In the following circumstances it will return to standard angle 1 pressing the manual switch 2 unplug and then plug in the machine So we strongly suggest that the open angle of the horizontal louver should not be set too small in case the condensed water forms and drops from the horizontal louver SELF CLEAN function Optional Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation Theunit will operate as following sequence FAN ONLY mode at Low fan speed Heating operation with LOW fan speed applicable to cooling amp heating modles only FAN ONLY operation Stop Operation Turn off Note This function is only available under COOL AUTO COOL FORCED COOL and DRY mode Before select the function it is recommended to run the air conditioner under Cooling operation for about half an hour Once the Self Clean function is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN bu
3. Before using your air conditioner please read this manual carefully and keep it for future reference INVERTER SPLIT TYPE ROOM AIR CONDITIONER USER S MANUAL Krimaire z ksiQ Read This Manual Tiend N as Keep this manual where the operator can easily find them Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service CONTENTS SAFETY PRECAUTIONS AAE aIla e E A A E eas scntaeennianteaisanes nceas duabieaeeee gga yuSleteant A E T 3 CAUTION EE E T E T E E S EEE 4 NAMES OF PARTS PRUE MG ear oe S E T EA SE AES T A E N T 5 outdoor unit Indication lamp OPERATING INSTRUCTIONS Special FUNC TONS srecna manekene E EERE E ERREAREN OAA An A AANE Ea EE E AEAEE ERREEN 6 Operating temperature re Manual operation tsa Airflow direction control 8 How the air conditioner WOFKS ou cee ceeccccccecee cece ceeeee cence eeeeeeeeeeeceeeeeeesseeseeeeeeeeseesneeseeeeeeeeeneetees 9 CARE AND MAINTENANCE Bette maintenance i ccs as areca kieran nadine neni ieee eins Cleaning thes Mitre see ipar aee ne EEE AAEN A AAEE EAA Aee AA AEAEE EEEE EE ERS Cleaning the a
4. ED COOL and DRY mode the air conditioner will run Anti mildew function for 7 10 minutes if turns off on HEAT mode the unit will continue operating for about 30 seconds at LOW fan speed then stop the operation and turn off the unit automatically 8 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity relative humidity higher than 80 Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed 9 Heating mode For cooling and heating models only The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 10 Auto restart function Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operation push the ON OFF button on the remote controller For the unit with Auto restart feature when the power restores the unit restarts automatically with all the previous settings preserved by the memory function TROUB
5. LESHOOTING TIPS Troubleshooting guide The unit may stop operation or continue OPERATION RUN indicator or other indicators continue flashing Trouble If one of the following code appears on the display area E0 E1 E2 E3 P3 or FO F1 F2 F3 PO P1 P2 to run in asafety condition depending on models Waiting for about 10 minutes the fault may be recovered automatically if not disconnect the power and then connect it in again If the problem still exists disconnect the power and contact the nearest customer service center Fuse blows frequently or circuit breaker trips frequently Other objects or water fall into the air conditioner Terrible odors are smelled or abnormal sounds are heard Stop the air conditioner immediately disconnect the power and contact the nearest customer service center Malfunctions Cause What should be done Unit does not start Power cut Wait for power to be restored Unit may have become Unplugged Check that plug is securely in wall receptacle Fuse may have blown Replace the fuse Battery in Remote controller may have been exhausted Replace the battery The time you have set with timer is incorrect Wait or cancel timer setting Unit not cooling lor heating Cooling heating Inappropriate temperature setting Set temperature correctly For detailed method please refer to
6. and air freshening filter 1 Remove the air filter 2 Remove the air freshening filter 3 Install a new air freshening filter 4 Reinstall the air filter and securely close the front panel Preparation for extended non operation If you plan to idle the unit for a long time perform the following 1 Clean the indoor unit and filters 2 Operate the fan for about half a day to dry the inside of the unit 3 Stop the air conditioner and disconnect power 4 Remove the batteries from the remote controller The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or service provider Pre season inspection Check that the wiring is not broken off or disconnected Clean the indoor unit and filters Check that the air filter is installed Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time A Caution Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Do not wash air filter with hot water at more than 40 C 104 F Shake off moisture completely and dry it in the shade Do not expose it directly to the su
7. ast free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacturer will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ignoring of instructions may cause harm or damage The seriousness is classified by the following indications Awarninc This symbol indicates the possibility of death or serious injury a CAUTION This symbol indicates the possibility of injury or damage to propery Meanings of symbols used in this manual are as shown below a S Strictly prohibited q O Be sure to follow the instructions r A WARNING N S e Do not extend the cable and never use multiple plugs A poor electrical connection poor insulation or voltage which is higher than permitted can cause fire Do not expose your body directly to the cool air for prolonged period Never poke fingers sticks or other objects in the air inlet and outlet vents e Never attempt to repair relocate modify t
8. eration When you set the air conditioner in AUTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on set temperature and the room temperature The air conditioner will control room temperature automatically to the temperature point you set If you feel uncomfortable in the AUTO mode you can set your desired temperature SLEEP operation When you push SLEEP button on remote controller during cooling heating cooling amp heating models only or AUTO operation the air conditioner will automatically increase cooling or decrease heating 1 C 2 F per hour for the first 2 hours then hold steadily for the next 5 hours after that it will switch off This mode saves you energy and brings you comfort at night DRYING operation The fan speed will be automatically controlled under dry operation During the dry operation if the room temperature is lower than 10 C 50 F the compressor stops operation and restarts until the room temperature is above 12 C 54 F Optimal operation To achieve optimal performance please note the following Adjust the air flow direction correctly so that it is not forwards people Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperature levels Close doors and windows on COOL or HEAT modes or performance may be reduced Use TIMER ON button on the remote controller to select a
9. he air conditioner yourself Always contact your service partner if it requires e Never pull the plug out by pulling on the cable Hold the plug firmly and pull it out of the plug socket otherwise there is a risk of damaging the cable Do not operate your air conditioner in a wet room such as a bathroom or laundry room Remove all dirt from the power plug and plug it firmly Soiled plugs can cause fire or an electric shock In the event of any abnormalities such as smell of burning immediately switch off the device and pull the plug Contact your service partner Always switch off the device and pull the plug before you start to clean it Use specified power cord Contact the authorized installer for installation of this unit Contact an authorized service technician for repair or maintenance of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the air conditioner SAFETY PRECAUTIONS fe CAUTION lt lt Never actuate any switches with a wet e f the air conditioner is to be used in hand It may cause an electric shock conjunction with other heaters the air Never use t
10. he device for any other should be refreshed periodically otherwise purpose than the intended use Never there is a risk of lack of oxygen place food precision instruments plants e Always pull out the power plug if the unit animals paint etc on the unit is not going to be used for any lengthy Do not expose plants or animals directly period of time Collections of dust can to the air flow cause fire Never clean the air conditioner with water e Always switch off the air conditioner and Never use combustible cleaning agents pull out the power plug during a storm as these could cause a fire or deformation Electrical parts may get damaged e Never place any burning objects close to e Check that the drainage line is correctly the device if they could be directly affected connected If not water will escape by the emitted air e Check that the condensation water can e Never step onto the outdoor device and run off unhindered It may cause water never place anything on it damage if the condensation water cannot e Never use an unsteady or rusty base run off properly Never install the air conditioner in places The air conditoner must be earthed in where combustible gas can be emitted accordance with the local codes Emmitted gas may collect and cause an e For electrical safety purposes we explosion recommend that you install an earth e Never allow the air conditioner to run for leakage circuit breaker too long with the doors
11. ir filter and air freshening filter Replacement of the air filter and air freshening filter 7 Preparation for extended non operation ccccccccccceeececeeeeeceeneeceeeeeeeeeeeeseeeeeeseeeeeeetesseeeeenee es Pre season INGDO CUO iss cicvnssencnscesstonins ae a weauadeanacsealenves Eea oonspee gues endweda ge casededa cen ANERE as TROUBLE SHOOTING TIPS Normal function of the air conditioner s sssssesetseee cece eeeeee ates ce eeeeee cases ceneeaaaeeeeeeaseeseeeeaeeees 12 Troubleshooting GUJE seient a a E aa a a a naia anaa 14 When using this air conditioner in the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision DISPOSAL Do not dispose of this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at le
12. ling operation Mode Temperature Heating operation Drying operation NOTE conditioner is used outside of the above co is below 0 C 32 F we strongly recommend guarantee it running smoothly Room temperature 17 C 32 C 0 C 30 C 10 C 32 C 62 F 90 F 32 F 86 F 50 F 90 F 0 C 50 C Outdoor temperature 32 F 122 15 C 30 C 0 C 50 C 5 F 86T 327 122T 15C 50C 5 F 122F For the models with low temperature cooling system 1 Optimum performance will be achieved within these operating temperatures If air might come into operation and cause the unit to function abnormally 2 If the air conditioner runs for a long time in cooling mode and the humidity is high over 80 condensed water may drip out of the unit Please sets the vertical air flow louver to its maximum angle vertically to the floor and set HIGH fan mode Suggestion For the unit adopts an Electric Heater when the outside ambient temperature nditions certain safety protection features you to keep the machine plugged in order to Manual operation Units are equipped with a switch to run emergency operation mode It can be accessed by opening the front panel This switch is used for manual operation in case the remote controller fails to work or maintenance necessary AUTO COOL Manual switch Suspension bars AUTO COOL Manual s
13. n it may shrink D TROUBLESHOOTING TIPS Normal function of the air conditioner The following events may occur during normal operation 1 Protection of the air conditioner Compressor protection The compressor can t restart for 3 4 minutes after it stops Anti cold air Cooling and heating models only The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached A When heating has just started B Defrosting C Low temperature heating The indoor or outdoor fan stop running when defrosting Cooling and heating models only Defrosting Cooling and heating models only Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner During this condition air conditioner will stop heating operation and start defrosting automatically The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost built up on the outdoor unit 2 Awhite mist coming out from the indoor unit e Awhite mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity e Awhite mist may generate due to moisture generated from defrosting process when the air conditioner restarts i
14. n HEAT mode operation after defrosting 3 Low noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running It is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak sound when the compressor is running or has just stopped running This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing e Anoise may be heard due to louver restoring to its original position when power is turned on 4 Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating models only mode When indoor temperature reaches the temperature setting on air conditioner the compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling and heating models only to the set point TROUBLESHOOTING TIPS 7 The air conditioner runs Anti mildew function after turning off the unit When turning off the unit under COOL AUTO COOL FORC
15. or windows open e If the power cord is damaged it must be or if the humidity is very high replaced by the manufacturer its service agent or similary qualified persons in order to avoid a hazard Ne eZ NAMES OF PARTS Indoor unit Names of parts Indoor unit Front panel Air inlet Air filter Air outlet Horizontal air flow grille Vertical air flow louver inside Display panel N a ade Bea Outdoor unit 8 Connecting pipe 9 Connecting cable 10 Stop valve Outdoor unit NOTE All the pictures in this manual are for explanation purposes only The actual shape D of the indoor unit you purchased may be slight different on front panel and display window The actual shape shall prevail Indication lam Indication lam ION indication lamp optional function This lamp illuminates when Clean Air feature is activated Signal receiver siele DEFROST indication lamp Enabled on cooling amp heating models only e wu ec Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation OPERATION indication lamp This lamp illuminates when the air conditioner is in operation 20 20 ko TIMER indication lamp Lights up during Timer operation E Temperature indicator Displays the temperature settings when the air conditioner is operational Displays the malfunction code 5
16. th a clicking sound For some models please use suspension bars to prop up the panel 2 Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder then pull it downwards 3 Remove the AIR FILTER from the indoor unit Clean the AIR FILTER once two weeks Clean the AIR FILTER with a vacuum cleaner or water then dry it up in cool place CARE AND MAINTENANCE jam ee een en O a Air freshening filter Ez eS ANNA A D ee Plasma Air filter Hold the two parts of Plasma where are marked with signal and lift it Then you can open the cover of the the plasma and remove the filter 4 Remove the Air Freshening Filters from its supporting frame The solution to disassemble may differ from each other for different filters Refer to and Clean the air freshening filter at least once a month and replace it every 4 5 months Clean it with vacuum cleaner then dry it in cool place A For the models with plasma do not touch the plasma within 10 minutes after you open the panel 5 Install the air freshening filter back into position 6 Insert the upper portion of air filter back into the unit taking care that the left and right edges line up correctly and place filter into position Replacement of air filter
17. time you want to start your air conditioner Do not put any object near air inlet or air outlet as the efficiency of the air conditioner may be reduced and the air conditioner may stop running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position CARE AND MAINTENANCE Care and Maintenance Before mainatenance eTurn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Power supply must be disconnectd before cleaning the indoor unit A CAUTIONS A cloth dampened with cold water may be used on the indoor unit if it is very dirty Then wipe it with a dry cloth e Do not use a chemically treated cloth or duster to clean the unit e Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Never use water hotter than 40 C 104 F to clean the front panel it could cause deformation of discoloration Cleaning the unit wipe the unit with a soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air freshening filter Aclogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it stops wi
18. tton on the remote controller again will stop the operation and turn off the unit automatically CLEAN AIR function on some models This air conditioner is equipped with ionizer or Plasma Dust Collector Depending on specific configuration of the model With the anions generated by lonizer the air circulation of the air conditioner fills the room with refreshing natural and healthy air The Plasma Dust Collector generates a high voltage ionization zone through which the air is converted to plasma Inside the air most of the dust smoke and pollen particles are captured by the electrostatic filter Anti mildew function Optional When turns off the unit on COOL DRY AUTO Cool mode the air conditioner will continue operating for about 7 10 minutes depending on models at LOW fan speed If turns off on HEAT mode the unit will continue operating for about 30 seconds at LOW fan speed This will help to dry up the condensed water inside the evaporator and prevent the breeding of mildew Under Anti mildew operation do not restart the air conditioner until the unit is completely off Vertical swing function Optional After the AC starts up users can control the vertical louver swing by the remote controller 6 OPERATING INSTRUCTIONS NOTE This manual does not include Remote Controller Operations see the lt lt Remote Controller Instruction gt gt packed Operating temperature with the unit for details Coo
19. vertical louver can only be adjusted manually Move the deflector rod manually to adjust the air flow in the direction you prefer IMPORTANT Do not put your fingers into the panel of blower and suction side The high speed fan inside may cause danger CAUTION e Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode Otherwise condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings When the air conditioner is started immediately after it Deflector rod was stopped the horizontal louver might not move for approximately 10 seconds e Open angle of the horizontal louver should not be set too small as COOLING or HEATING performance may be impaired due to too restricted air flow area Do not move the horizontal louver manually otherwise Rang the horizontal louver will be out of sync Please cease operating unplug power for a few seconds then restart the air conditioner Do not operate unit with horizontal louver in closed position OPERATING INSTRUCTIONS How the air conditioner works SLEEP operation 7 hours timer off Set Temperature 1 C 2 F m k 1hour 1hour Cooling SLEEP operation 7 hours timer off F al T Set 1 C 2 F Temperature t1 CIZE 1 e hour 1hour Heating AUTO op
20. witch D NOTE The unit must be turned off before operating the manual control button If the unitis operational continue pressing the manual control button until the unit is off Open and lift the front panel up to an angle until it remains fixed with a clicking sound For some models please use suspension bars to prop up the panel One press of the manual control switch will lead to the forced AUTO operation If press the switch twice within five seconds the unit will operate under forced COOL operation Close the panel firmly to its original position CAUTION This switch is used for testing purposes only You had better not choose it Torestore the remote controller operation use the remote controller directly Q OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the horizontal vertical louver using the remote controller For some models the vertical louver can only be adjusted manually e Perform this function while the unit is in operation To set the horizontal vertical air flow direction Range e Use the remote controller to adjust the air flow direction The vertical horizontal louver changes 6 degree in angle for each press or swing up and down automatically Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details For some models the