1. can be used to reset all Function values to factory default values 4 Warranty conditions Enerdrive warrants this product to be free from defects in workmanship or materials for 24 months from the date of purchase During this period Enerdrive will repair the defective product free of charge Enerdrive is not responsible for any costs of the transport of this product This warranty is void if the product has suffered any physical damage or alteration either internally or externally and does not cover damage arising from improper use or from use in an unsuitable environment This warranty will not apply where the product has been misused neglected improperly installed or repaired by anyone other than Enerdrive Enerdrive is not responsible for any loss damage or costs arising from improper use use in an unsuitable environment or improper installing setup and malfunctioning of the product Since Enerdrive cannot control the use and installation according to local regulations of their products the customer is always responsible for the actual use of these products Enerdrive products are not designed for use as critical components in life support devices or systems that can potentially harm humans and or the environment The customer is always responsible when implementing Enerdrive products in these kind of applications Enerdrive does not accept any responsibility for any violation of patents or other rights of third partie
2. Enerdrive DRIVING YOUR ENERGY NEEDS ELITE battery monitor D Thank you for purchasing an Enerdrive Battery Monitor Please read this owner s manual for information about using the product correctly and safely Keep this owner s manual close to the battery monitor for future reference Owner s manual Enerdrive Pty Ltd Unit 11 1029 Manly Road Tingalpa Brisbane Queensland 4173 Australia http www enerdrive com au Before proceeding with this owner s manual please make sure you have carefully read the enclosed installation guide as well 1 eLITE display and control overview 3 4 Enerdrive a e Y tsaaaatiill peel syochronize Vv A Ah 7 1 EACT AAT ELITE battery monitor 10 Charge battery indicator Alarm activated indicator Numeric value indicator field Readout units Main battery or Auxiliary battery indicator State of charge bar Synchronize indicator Select State of charge readout or next value gt Select current A or Amphour Ah readout or enter leave Setup menu 0 Select voltage readout Main or Auxiliary or previous value lt ZORO Gh ON 2 Synchronisation In order to keep your battery monitor delivering accurate status information about your battery it is important to regularly synchronize your battery monitor with your battery As explained in the quick start guide a synchronisation step is also needed before you can actually use your batter
3. ected shunt With standard delivered 500A 50mV shunt 350A continuous the range is limited to 600 600A 6 Declaration of conformity CE IMPORTER Enerdrive Pty Ltd ADDRESS Unit 11 1029 Manly Road Tingalpa Brisbane Queensland 4173 Australia Declares that the following products PRODUCT TYPE MODEL BATTERY MONITOR eLITE Conforms to the requirements of the following Directives of the European Union EMC Directive 2004 108 EC RoHS Directive 2002 95 EC The above product is in conformity with the following harmonized standards EN61000 6 3 2001 EMC Generic Emissions Standard EN61000 6 2 2005 EMC Generic Immunity Standard Enerdrive eLITE Manual Rev1e Printed in The Netherlands
4. he alarm relay will be activated Default 10 5V Range 8 0 33 0V Step size 0 1V 5 06 Low battery alarm Off SOC When the State of charge percentage has risen above this value and the alarm relay was activated the alarm relay will deactivate again When FULL is selected the alarm relay is deactivated when the Auto sync parameters are met Default 80 Range 1 100 FULL Step size 1 F07 Peukert s exponent The Peukert s exponent represents the effect of reducing battery capacity at higher discharge rates When the Peukert value of your battery is unknown it is recommended to keep this value at 1 25 A value of 1 00 disables the Peukert compensation Default 1 25 Range 1 00 1 50 Step size 0 01 n 08 Shunt Amp Rating This Function represents the Amp rating of your shunt at 50mV Included with your battery monitor is a 500Amp 50mV shunt meaning that at 500A flowing through the shunt a voltage of 50mV is generated across the small Kelvin screw terminals of the shunt This voltage will be used by the battery monitor to measure the amount of current Default 500A Range 10 900A Step size variable n 09 Backlight mode Represents the duration of backlight activation in seconds after key press The backlight can also be set to be always ON or always OFF Function setting AU activates the backlight automatically when charge discharge current exceeds 1Am
5. justing these values yourselves When your battery system is 24V besides checking battery capacity Function F01 for the correct value you should also change the values of F02 and F05 Default 24V system values for F02 and F05 are respectively 26 4V and 21 0V The following Functions are available F01 Battery capacity Your Main battery s capacity in Amphours Ah Default 200Ah Range 20 999Ah Step size 1Ah Gnl 02 Charger s float voltage Auto sync parameter This value must be equal to your battery charger s float voltage which is the last stage of the charging process In this stage the battery is considered full Default 13 2V Range 8 0V 33 0V Step size 0 1V an 03 Charger s float current Auto sync parameter When the charge current is below this percentage of the battery capacity see Function F01 the battery will be considered as fully charged Make sure this Function value is always greater than the minimum current at which the charger maintains the battery or stops charging Default 2 0 Range 0 5 10 0 Step size 0 1 a 04 Low battery alarm On SOC When the State of charge percentage has fallen below this value the alarm relay will be activated the Charge battery indicator starts flashing and the State of charge bar is empty Default 50 Range 0 99 Step size 1 F05 Low battery alarm On Volts When the battery voltage has fallen below this value t
6. p or when a key is pressed Default 30sec Range OFF 5 300 ON AU Step size variable a 10 Alarm contact polarity Enables selection between a normally open NO or normally closed NC contact Default NO Range NO NC a 11 Auto sync sensitivity Only change this setting when F02 and F03 are set correctly and automatic synchronization still fails If automatic synchronization takes too long or does never occur lower this value When the battery monitor synchronizes too early increase this value Default 5 Range 0 10 Step size 1 a 12 Firmware version Displays the firmware version of the battery monitor read only Default x xx The last two Functions are socalled Reset Functions By pressing the SETUP key the selected Reset Function can be viewed The default value for all Reset Functions is OFF To actually reset the selected Function use the lt and gt keys to change the value from OFF to ON Pressing the SETUP key again will step back to the Setup menu All reset items set to ON will only be reset once the Normal Operating Mode is accessed again by pressing the SETUP key for 3 seconds The following Reset Functions are available b Reset Battery status Use this reset item to reset your current battery status for example after you have installed a fresh battery of the same specifications as the previous one F Reset Functions This reset item
7. s resulting from the use of the Enerdrive product Enerdrive keeps the right to change product specifications without previous notice Examples of improper use are too high input voltage applied wrong shunt connection applying battery voltage to shunt input mechanically stressed enclosure or internals due to harsh handling and or incorrect packaging contact with any liquids or oxidation caused by condensation 5 Technical specifications Parameter eLITE Supply voltage range 9 35VDC Supply current Vin 24VDC 7mA Vin 12VDC 9mA Input voltage range auxiliary battery 2 35VDC Input voltage range main battery 0 35VDC Input current range 999 999A Battery capacity range 20 999Ah Operating temperature range 20 50 C Readout resolution voltage 0 35V 0 1V current 0 100A 0 1A current 100 999A 1A amphours 0 99Ah 0 1Ah amphours 100 999Ah 1Ah state of charge 0 100 0 1 Voltage measurement accuracy 0 3 Current measurement accuracy 0 4 Dimensions frontpanel 64mm body diameter 52mm total depth 79mm Weight 95grams Shunt dimensions footprint 45 x 87mm height 17mm base 35mm M8 screws weight 145 grams Protection class IP20 frontpanel only IP 65 Professional connection kits Quick connection kits Accessories Note the given specifications are subject to change without notice Measured with backlight and alarm relay turned off 2 Depends on sel
8. ter these three seconds the flashing FULL message appears on the the display just like when it is automatically synchronized 3 Setup menu Using the Setup menu your battery monitor can be adjusted to fit into your system A number of parameters called Functions can be set according to your needs This menu can be accessed by the following sequence 3 sec Fol E When the Setup menu is entered you can use the lt and gt keys to browse through the different Functions By pressing the SETUP key the selected Function value can be viewed The lt and gt keys can now be used to change this value Pressing the SETUP key again will then step back to the Setup menu From any menu position the Normal Operating Mode can be accessed again by pressing the SETUP key for 3 seconds This will also save any Function value changes to internal memory When no keys are pressed for 90 seconds while operating in the Setup menu the battery monitor will automatically return to the Normal Operating Mode again without saving any Function value changes The factory settings are based on a 12V battery system with a capacity of 200Ah For 12V systems generally only Function F01 has to be checked for correct operation of your battery monitor When your battery capacity is other than 200Ah Function F01 has to be changed to a value that is equal to your battery capacity All other Functions can be left unchanged if you are uncertain about ad
9. y monitor During operation the battery monitor automatically indicates when a synchronisation is required by displaying the message SYNCHRONIZE A synchronisation step means nothing more than performing a complete charge cycle on your battery A charge cycle will be considered complete when all discharged energy is restored in the battery and both Auto sync parameters F02 and F03 are met during at least 4 minutes This typically means when the battery charger switches to float mode By meeting these conditions the battery is considered full which will be indicated by a flashing FULL message on the display Besides this the State of charge readout will be set to 100 and the Amphour readout reset to OAh The FULL message will disappear when a key is pressed or automatically when the battery starts discharging again Performing synchronisations regularly is also important to keep your battery healthy and to increase it s lifetime You will notice that if you are often performing full charge cycles yourselves the battery monitor will most likely not display the SYNCHRONIZE message since the battery is already kept in good sync with the battery monitor Besides automatic synchronisations based on meeting the Auto Sync Functions you can also manually synchronize the battery monitor with your battery when you are sure your battery is fully charged This can be accomplished by pressing both lt and gt keys simultaneously for three seconds Af
Download Pdf Manuals
Related Search
Related Contents
Husqvarna O0803001 User's Manual 電子申告キャンペーンのご案内 PRODUCT FACT SHEET FM 3306 and FM 3316 Overview Features Fiche produit - Nicolas Entretien Infineon C508 User`s Manual Harbor Freight Tools 2 Ton Cable Winch Puller Product manual Nedis VLSP41800W20 coaxial cable Digital Still Camera ISE シリーズ取扱説明書 Copyright © All rights reserved.