1. Manuals The following shows manuals relevant to this product Detailed Manual Manual Number Manual name Model code GT16 User s Manual SH 080778ENG Sold separately 1D7M88 GT15 User s Manual SH 080528ENG Sold separately 1D7M23 GOT1000 Series Connection Manua SH 080532ENG Sold separately 1D7M26 Relevant Manuals For relevant manuals refer to the PDF manuals stored in the GT Designer2 CD ROM 2005 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives refer to EMC AND LOW VOLTAGE DIRECTIVE of GT15 User s Manual The CE logo is printed on the rating plate of the GOT indicating compliance with the EMC and low voltage directives Packing List The following items are included Model Product Quantity Bus connection unit 1 GT15 QBUS GT15 ABUS Mounting screws set 2 screws 2 1 stickers Bus connection unit 1 GT15 QBUS2 Mounting screws set 2 screws 2 GT15 ABUS2 stickers Extension interface relay board 1 Item GT15 GT15 GT15 GT15 QBUS QBUS2 ABUS ABUS2 IN 1 1 1 1 Connector OUT 1 1 16 points 32 points I O occupied points I O assignment I O assignment 16 intelligent points
2. 1 Overview This User s Manual describes the GT15 bus connection unit hereafter abbreviated to the bus connection unit Use the bus connection unit for making bus connection of the GOT Refer to GT16 User s Manual or GT15 User s Manual for the applicable GOT 2 Specifications The performance specifications of the bus connection unit are indicated below The general specifications of the bus connection unit are the same as those of the GOT Refer to GT16 User s Manual or GT15 User s Manual for the general specifications of the GOT Kem GT15 GT15 GT15 GT15 QBUS QBUS2 ABUS ABUS2 Interface QCPU Q Mode QnA ACPU bus connection bus connection 3 Part Names and External Dimensions 1 GT15 QBUS GT15 ABUS 107 4 13 2 GT15 QBUS2 GT15 ABUS2 E Model A B Cc D 23 12 31 5 GT15 QBUS 0 09 0 47 1 24 g 2 5 1 29 33 5 GT15 QBUS2 0 10 0 43 4 44 4 32 45 15 29 5 GT15 ABUS 0 18 0 59 1 16 i 45 1 31 31 GT15 ABUS2 0 18 0 43 4 22 4 22 Unit mm inch Dimensions of X when the bus connection unit is mounted to the GOT GOT GT16 GT15 15 19 5 0 78 21 0 83 12 1 18 0 71 18 0 71 10 4 21 0 83 8 4 5 7 z 23 0 92 Unit mm inch No Name
3. Special 32 points Internal current 0 44A 0 44A 0 12A 0 12A consumption 5VDC 0 13kg 0 14kg 0 13kg 0 14kg Weight 0 291b 0 31Ib 0 291 0 31Ib When the GOT power is on the internal current consumption is included in the current consumption of the GOT When the GOT power is off the internal current is supplied from the power supply of the PLC system Select the used bus connection unit according to the connection target and connection position lt Bus connection unit selection example gt 1 Select the bus connection unit according to the connection target QCPU Q Mode motion controller Q series GT15 QBUS GT15 QBUS2 ACPU QnACPU motion controller A series GT15 ABUS GT15 ABUS2 M 2 Select the bus connection unit according 3 E to the GOT connection position 4 m m Placed midway GT15 QBUS2 GT15 ABUS2 Placed at end GT15 QBUS GT15 ABUS GT15 QBUS2 GT15 ABUS2 When using the bus connection make the communication settings to perform communication between the GOT and PLC Refer to GOT1000 Series Connection Manual for details of bus connection When using bus connection unit use a standard monitor OS and communication driver of GT Designer2 Version2 15R or later With a standard monitor OS and communication driver of an older version the GOT has cannot recognize the unit to perform monitoring
4. Description Bus connector 1 Connector for connecting the IN side bus connection cable IN side Bus connector Connector for connecting the 2 OUT side bus connection cable OUT side Extension connector installed to 3 InlerielCe Connector a front extension unit or the GOT Extension connector to which a 4 Extension connector back extension unit is installed Mounting screws fixed with a 5 Mounting screw front extension unit or GOT Screw for fixing the extension 6 Board fixing screw interface relay board 7 Rating plate 4 Installation Procedure The method for mounting and removing the bus connection unit is explained using the GT 15 as an example Refer to the GT16 User s Manual for the bus connection unit mounting and removal methods for the GT16 1 GT15 QBUS GT15 ABUS 1 Power off the GOT 2 Remove one extension unit cover of the GOT 4 Fasten the bus connection unit by tightening its mounting screws 2 places with tightening torgue 0 36 to 0 48 Nem 5 When installing an extension unit on the unit that has been installed remove the connector cover and the sticker When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mounting screws 2 places Keep the connector cover fixed Keep the sticker stuck as it is Accessor
5. MITSUBISHI MODEL GT15 QBUS GT15 QBUS2 GT15 ABUS GT15 ABUS2 BUS CONNECTION UNIT User s Manual Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 BUS U MODEL CODE 1D7M39 IB NA 0800323 F 0810 MEE GRAPHIC OPERATION TERMINAL GOTio900 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION 7 A Indicates that incorrect handling may cause d DANGER hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause A CAUTION hazardous conditions resulting in medium or slight personal injury or physical damage en Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to personal safety Please save this manual to make it accessible when required and always forward it to the end user DESIGN PRECAUTIONS A CAUTION Do not bunch the control wires o
6. al Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasa
7. n Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan
8. ng always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction CAUTION Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of GT16 User s Manual or GT15 User s Manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation
9. r communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS lt gt DANGER Before mounting or dismounting this unit to or from the GOT always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction CAUTION Use this unit in the environment given in the general specifications of GT16 User s Manual or GT15 User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS lt gt DANGER Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction A CAUTION Insert and fit the bus connection cable into the connector of the unit to be connected until it clicks After fitting check for lift which can cause a malfunction due to a connection fault STARTUP AND MAINTENANCE PRECAUTIONS DANGER Before starting cleani
10. shi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni P
11. y sticker Connector l T cover t Sticker 2 GT15 QBUS2 GT15 ABUS2 1 Power off the GOT 2 Remove two extension unit covers of the GOT 3 Attach the extend interface relay board to the extend I F 2 side on the GOT After the installation detach the connector cover from the extend inter face relay board For GT155 the extension interface relay board is not needed 4 Fit the bus connection unit in the GOT case Remove the connector 5 Fasten the bus connection unit by tightening its mounting screws 4 places with tightening torgue 0 36 to 0 48 Nem 6 Fasten the bus connection unit by tightening the board fixing screws 2 places with the tightening torque of 0 36 to 0 48 Nem 7 When installing an extension unit on the unit that has been installed remove the connector cover and the sticker When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mounting screws 4 places Keep the connector cover fixed Keep the sticker stuck as it is Connector cover Accessory sticker Accessory sticker Point Remove the screws that fixes the extend interface relay board before removing the unit Above 6 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubi