1. 12 0 1 4t Disable and enable SMS Messages function e 0 means not activated e 1 means activated e Example to disable SMS Messages function send SMS Messages 1234120 or using phone should input 1234 12 0 EASY INSTALLATION INSTRUCTIONS 1 Mount monitor panel where indication lights can be readily seen 2 Mount bilge level switch in centerline of boat and above any residual bilge water Insert 1 wire from the bilge level switch and one wire from the alarm cable Co on pA penn into the two holes in the crimp and compress with pliers This will connect i ke the two wires and the surplus silicone grease will be expelled no need to strip insulation Repeat this process with the second wire Waterproof Crimps 1 If using a wireless bilge switch ensure the wireless module is mounted as high as possible to safeguard against water ingress Mount smoke detector in cabin away from galley area 4 Mount PIR as high as is practical above the sole The sensor should face the detected area at 90 for best coverage 5 Proximity switch Fix magnet to locker door or washboard and fix transmitter to fixed side maintaining 6mm or less gap between edges see operating light on off 6 Run supply cable from the battery you wish to monitor and connect via fuse on lead 7 Run alarm cable from bilge level switch and gas detector to panel 7 gnd amp 8 gnd 8 Insert SIM card and energise supply 9 When the panel settles with G
2. the signal LED blinking quickly SIM card un loaded SIM card is setting PIN code GSM signal weak e reload SIM card e cancel PIN code of SIM e change to a place with a stronger signal Suggested TEXT TEMPLATES for your phone TEXT Set alarm 12341 ALARM ON Unset Alarm 12340 ALARM OFF Relay On Heating 12343 HEATING ON Relay Off Heating 12344 HEATING OFF Alarm Status Enquiry 123420 ALARM STATUS Alert amp Alerting Number 123421 ALERT ALERTING No Add Phone Nol for SMS 12343 JP 1 SMS phone No Add Phone No 2 for SMS 123438 TERE Ek 2 SMS phone No Clydebuilt Marine Electronics www cbme co uk boatsteward User manual 1 System Foreword This wireless GSM intelligent monitoring system is built on leading microprocessor technology with advanced GSM digital signal processing power It is a highly integrated system of text messages multiple mode s of wireless coding long distance appliances controlling short messages identification and other technologies When alarming it will automatically inform of the alerting device and location through text messages It is stable reliable and safe With human manipulation and telecom phone line removed it can be comprehensively applied to places at which wire phone networks can NOT cover the protection needed It is able to protect users property and personnel safety as well as monitoring the boat 2 General introductio
3. 10 Troubleshooting Problem Probable Reasons Available Solutions 1 Alarm does not dial out not arming alerting phone incorrectly set parts improperly installed code no match SIM card overdue e do arming operation e re set according to the spec e Relocation of parts e re code e 5 Top up the SIM card 2 cannot operate by phone password or SMS input incorrect e retry password SMS or reset password 3 no message indication when alerting SMS message not recorded e record SMS message 4 remote control keyfob out of order coding un matched with the Panel insufficient battery power battery has poor contact or voltage e re learn the remote control e change battery to correct type e contact www boatsteward co uk e to change the matched remote control keyfob 5 infrared detector out of order low power e Renew battery 6 siren without sound siren plug or jack in short circuit or broken line siren out of order closed siren by command e repair or change plug or jack e change the jack line e activate siren by command e use another siren to double check 7Panel not receiving detector a nearby emitter is sending code Panel receiver stoppage standby battery of the Panel insufficient e move one detector next to panel and try again e identify the interfering source and eliminate it e check Panel power is on 8
4. S text is 07974699999 Send text 12343707974699999 to the SIM number in the monitor panel Default password 1234 code no 37 mobile number to be alerted 07974699999 To change the password follow instructions below 50 new password 1234 504321 Modify user operation password e For example If user wants to set new user password as 4321 please send SMS message 1234504321 or using phone input 6 SMS programming wAll programming for this panel are accomplished through cell phone call to the host GSM card and sending short messages On working status and the GSM network detection is normal Send the following TEXT commands 1 General command pattern sent via SMS is password command parameter e g setting SMS phone no 1234379999999 37 user number Add or delete 1 group of phone number for receiving SMS messages Example if the user wants to add phone number 12345678 send This is the first and SMS Messages 12343712345678 or using phone should input possibly only 1234 37 12345678 programming to do Example if the user wants to delete second group number send SMS Messages 123437 or using phone should input 1234 37 38 user number Add or delete 2 group of phone number for receiving SMS messages 39 user number Add or delete 3 group of phone number for receiving SMS messages SMS on setting as follow
5. SM light flashing every 3 seconds put panel switch ON 10 Operate the panel with the remote control and trigger all sensors individually 11 Operate panel with mobile phone and check operation
6. ect the DC power Upon power up the alarm panel will carry a self test sequence as below e Six Defense Zones LED and two Functional LED s on front panel will flash in order once each and end with a buzzer long Beep e The GSM Signal LED flashes with one second interval for checking the GSM signal e If GSM network detected all right Beep sound stops and Signal LED becomes flashing every three seconds the GSM signal and SIM card are all confirmed normal system is READY Now switch the stand by battery switch to ON m indicating information Buzzer Short Beep once Key pressing indication Long Beep once Confirm receipt of a key stroke Continuous short Beep for 2 times Correct command received Continuous short Beep for 3 times Error in command Beep at moderate intervals SIM card not found Defense Zone Always lit Defense zone alerting LED Blinking Defense zone coming into delayed alerting Arming LED Always lit Arming status Blinking quickly Stay safe arming status Blinking slowly Coming into delayed arming status GSM signal Blinking every 1 second GSM signal weak or SIM card not found LED Blinking every 3 seconds GSM module and SIM card working properly Not lit Without electricity Inputing SMS called number do this now 37 user number Example mobile number you wish to be sent SM
7. f the detector in the Defense zone is triggered only once it will not immediately alarm But if being triggered once again within 30 seconds after the first triggering it will alarm immediately EMERGENCY Defense zone no matter on arming or disarming status if detector is triggered it will alert Usually used in connection with Smoke Detectors Gas Detectors and emergency button etc CLOSED Defense zone no matter arming or disarming status detectors will not alert even being triggered 4 Installation and debugging mhost and 2G SIM card installation The panel should be installed in a central zone of the monitored area so as to make sure that all wireless detectors can be best received Take care to keep away from large scale metal objects or appliances with high frequency interference The control panel 1 sov seg sm GSM BALARMBA E 4 YE ku ome jse Fi N iw NEAR Speaker optional for future use DISARM Remote Control Unit Sim Card Installation Connection of wired sensors amp relay Relay connect NO and C between the load to be controlled Sensors Bilge level switch connect Gnd To 7 Gas alarm relay connect Gnd To 8 Zone 9 connect Gnd To 9 Zone 10 connect Gnd To 10 5 The GSM host settling First time energization Ensure the SIM card use a 2G only all wired sensors if applicable and antenna are correctly installed then conn
8. into the shore power in order to monitor this supply e Input voltage DC 9V 12V e Standby current lt 25mA e Alerting current lt 450 mA e Wireless frequency 315 433 868 915MHZ 2262 1 5 4 7M EV1527 300K e GSM SYSTEM supporting GSM850 900 1800 1900MHz 2G Sim Card only e Standby battery NI HI AAA 6 DC7 4V e Siren loudness 110dB O Accessories parameters this panel is compatible with PT2262 code PT2240 code and EV1527 shorten code Servicing The PIR s have an on off switch on the side which can be switched off when onboard so as to prolong the battery life Although the battery life of individual detectors can vary it is recommended that the batteries be renewed on an annual basis and be tested frequently The MOB fobs after prolonged immersion or for annual service in order to maintain their integrity should be returned to CBME Clyde Marina Ardrossan Ayrshire Scotland KA22 8DB Operation Commands amp Programming Commands 0 DISARM SMS Messages disarming send SMS Messages 12340 1 ARM SMS Messages arming send SMS Messages 12341 2 STAY ARM SMS Messages STAY arming send SMS Messages 12342 3 RELAY ON SMS Messages Relay closing send SMS Messages 12343 4 RELAY OFF SMS Messages Relay opening send SMS Messages 12344 20 Find arming and disarming status send SMS Messages 123420 21 Find alerting number and alert receiving number configu
9. n of functions mten zones set as normal stay intelligent emergency open or closed types etc mUsing phone cellphone or SMS to configure amp control the panel remotely m Four wired zones six wireless zones each zone can be equipped with many accessories m Three groups of phone numbers for SMS messages One normally open signal output which can be externally linked to operate heating etc m Built in short message contents Short message content from alarming zone can be amended m Wireless intelligent study coding compatible with 2 262 normal encoding and a million group encoding convenient and flexible for adding or reducing accessories mTelephone long distance telecontrol for arming disarming and controlling appliances mEEPROM information protection information will never be lost mBuilt in NI Lithium battery will automatically be transferred to stand by after outage with short message prompting EDC supply and standby twenty four hour normal guarding and unbroken service mPanel using double triple or quadruple GSM GPRS wireless industry module depending on model which is stable and reliable 3 Arming Disarming Operations 3 1 Arming Arming means that all detectors are working When something triggers the detectors the alerting system will alarm at once After arming operation the Set light on the panel will remain on until it has been reset by the remote control or by SMS Remote control operation press
10. red in the panel send SMS Messages 123421 80 Used to inquire as to SMS Messages contents from all Defense zones e For example send SMS Messages 123480 81 Defense zone one SMS Messages content 82 Defense zone two SMS Messages content Used to set SMS Messages content given by Panel when the first Defense zone alerts SMS Messages content can NOT exceed twelve characters e For example send SMS Messages 123481 Man overboard At that time when the first Defense zone is triggered the SMS Messages of Man overboard will be sent as a short message to alarming number Used to set SMS Messages content given by Panel when the second Defense zone alerts ditto 83 Defense zone two SMS Messages content Used to set SMS Messages content given by Panel when the third Defense zone alerts ditto 84 gt 89 Messages for ZA gt Z9 The forth to ninth Defense zone can be inferred as above 90 Defense zone ten SMS Messages content Used to set SMS Messages content given by Panel when the tenth Defense zone alerts ditto 7 Note Difference between Defense Zone Types NORMAL Defense Zone the Panel only works on the arming status When disarming there is no response e STAY Defense zone can be shut off solely through the remote control keyfob to ensure no external influence will cancel this function e INTELLIGENT Defense zone i
11. the arming key in the remote control unit once will Set Phone Send SMS 12341 and receive a confirmation TEXT 3 2 Stay arming Stay is for arming the Gas detector Smoke detector and bilge alarm but not the PIR or Proximity switch When armed the Set light on the panel will flicker Remote control operation press Arming key and the Stay key in the remote control unit once each will Set 3 3 Disarming operation Disarming means that when the panel alerts it can stop the alerting or put the system into disarm status After disarming even triggering detectors can NOT make the panel alert except for the detectors in emergency Defense zone s i e MOB fob or the emergency key in the remote control unit After disarming arming light goes out Remote control operation press the disarming key in the remote control unit once will reset Phone Send SMS 12340 and receive a confirmation TEXT 3 4 Emergency alerting If an emergency arises press the emergency key on the remote control unit or the MOB man overboard fobs this in turn will operate the sounder and send a text message 8 Leaving factory default Password 1234 Long distance control Open Ringing times once Siren timing 1 minute Aural remote control siren open Delayed arming Osecond Delayed alerting 0 second 9 System Specification e A230v gt 12V de adaptor is supplied which enables the unit to be set up at home and or plugged