Contents
1. DLs users OOOO a OPTIONAL ITEMS Optional chest plate for collecting chest motion and breathing data using an optical tracking system LIMITED WARRANTY All standard CIRS products and accessories are warranted by CIRS against defects in material and workmanship for a period as specified below During the warranty period the manufacturer will repair or at its option replace at no charge a product containing such defect provided it is returned trans portation prepaid to the manufacturer Products repaired in warranty will be returned transportation prepaid There are no warranties expressed or implied including without limitation any implied warranty of merchantability or fitness which extend beyond the description on the face hereof This expressed warranty excludes coverage of and does not provide relief for incidental or consequential damages of any kind or nature including but not limited to loss of use loss of sales or inconvenience The exclusive remedy of the purchaser is limited to repair recalibration or replacement of the product at manufacturer s option This warranty does not apply if the product as determined by the manufac turer is defective because of normal wear accident misuse or modification Non Warranty Service If repairs or replacement not covered by this warranty are required a repair estimate will be submitted for approval before proceeding with said repair or replacement Product
2. Waray Period Non Standard or customized products Training Phantoms and Disposable Products Electrical Products and Dynamic Phantoms 12months All other standard products 48 months Plastic Water 60 months MODEL 008PL FEATURES e Move any phantom with sub millimeter accuracy and reproducibility e Surrogate and phantom motion fully and independently programmable e Easy transport set up and operation e Motion software enables different cycles amplitudes and waveforms e Surrogate breathing platform accommodates numerous gating devices CIRS COMPUTERIZED IMAGING REFERENCE SYSTEMS INC 2428 Almeda Avenue Suite 316 Norfolk Virginia 23513 USA Toll Free 800 617 1177 Tel 757 855 2765 Fax 757 857 0523 E mail admin cirsinc com www cirsinc com Technical Assistance 1000 6174177 Computerized Imaging Reference Systems Inc has 2013 Computerized Imaging Reference Systems Inc been Certified by UL DQS Inc to ISO 9001 2008 All rights reserved All brand names product names or trademarks iS Certificate Registration No 10000905 QM08 belong to their respective holders Specifications subject to change without notice Publication OO8PL PB 012915
3. and fixation of almost any phantom and traditional laser alignment marks enable accurate positioning of the entire device An independently controlled smaller platform provides Posterior Anterior sur rogate chest wall motion Computerized Imaging Reference Systems Inc is recognized world wide for tissue simulation technology and is the leader in the manufacture of phantoms and simulators for medical imaging and radiotherapy www cirsinc com Programmable Motion for Any Phantom TH PYNE Een NN Model OO8PL shown with CIRS Plastic Water DT stack Phantom available separately TA ane Model OO8PL shown with CIRS Model OO2H9K IMRT Head and Torso Freepoint Phantom Phantom available separately Easy To Use Software Graphical user interface simplifies operation of the Model 008A CIRS Mation Control Adjust motion amplitude cycle time and phase shift with pull down menus and slider bars File Motid View Help Instantly Start Stop Pause or Loop motion LY Inferior Superior aveform Cos6 Amplitude 10 00 mm Cycle Time 4 000 sec Phase Shift 0 000 sec Start Position 0 00 mm Average Position 3 64 mm Current Position 10 00 mm Anterior Posterior Waveform s Amplitude Cycle Time Phase Shift Start Position i Average Position 0 00 mm Current Position 0 00 mm AAV OAV G Lateral Waveform Amplitude Cycle Time Phase Shift Start Position Average Position 0 00 mm Cur
4. a A a i E i S Wi m a l ATI A y E d i a y C a Uy ee y Model 008PL TN BYNES Strict QA procedures for the imaging planning and delivery of radiotherapy using respiratory management devices are required to ensure the safe and effective use of these devices AAPM TG 76 report The management of respiratory motion in radiation oncology 2428 Almeda Avenue Suite 316 Norfolk Virginia 23513 USA Tel 800 617 1177 757 855 2765 Fax 757 857 0523 WWW CIRSING COM O CAPABILITIES e Commission 4D imaging and 4D radiotherapy systems e Quantify volumetric and posi tional aliasing of CT in the presence of 3D target motion e Evaluate static and dynamic target localization accuracy of onboard imaging systems e Test accuracy and consistency of tumor tracking and respiratory gating devices e Assess dosimetric accuracy of temporally modulated radiation therapy e Train and evaluate personnel during implementation of new equipment and techniques Overview The CIRS Dynamic Platform provides an economical user friendly solution for the com plex tasks associated with tumor motion and patient positioning in radiation therapy The platform is made from stiff low density plastics The device enables precisely con trolled inferior superior motion up to 50 mm for any phantom up to 70 lbs A removable pin system in the main platform allows consistent placement
5. convenient real time graphic display of pre selected target start position current position during operation and average time weighted position In addition the ROI analyzing function provides the time spent by the target between two chosen amplitudes and the average time weighted position for that particular ROI Users can instantly start stop or pause the motion at any time New start positions can be graphically selected and applied making the device very useful for static test as well as dynamic testing Users can also select the number of cycles to be looped by entering the desired value or choose continuous looping 1 million cycles Independently Controlled Surrogate Motion The surrogate motion is mechanically independent of platform motion and programmable through the CIRS Motion Control Software This feature provides even greater flexibility to the clinician and is useful in assessing correlation between surrogate and phantom motion Surrogate AP motion range of up to 50 mm can be achieved The surrogate platform motor is powerful enough to accommodate bel lows and other belts in addition to Varian RPM and various tracking fiducials e Maximum surrogate motion is 50 mm e Minimum cycle time is 1 second e Maximum cycle time is unlimited Advanced Electromechanical Components CONTROLLER Motions are generated through a multi axis motion controller A USB port enables interfacing with most computers The contro
6. ller sends instructions as well as supplies and conditions power to the actuators thru a 25 pin serial cable The motion controller can be fully operated through CIRS Motion Control Software from a distance of up to 70 feet with the Ethernet USB cable provided ACTUATOR Housed within anodized aluminum enclosures the actuators con tains bipolar stepper motors Maximum range of inferior superior IS platform motion is 50mm with an accuracy of 0 05 mm Maximum range of anterior posterior AP surrogate motion is 50mm with an ac curacy of 0 05 mm Motions can be synchronized to one another with accuracy better than 20 msec Motion cycle time accuracy is better than 5 msec Optical sensors ensure precise mechanical positioning The actuators are designed for continuous operation If not manually stopped and reset by the user they will perform 1 000 000 in continu ous mode cycles then stop automatically Model 008PL Specifications E T E T sin t 1 2cos4 t 1 2cos6 t sawtooth sharkfin CIRS Motion Control Software System Requirements Windows XP Pentium 3 or equivalent 512 MB RAM 2 MB of available disk space Ordering Information INCLUDED WITH MODEL 008PL cont uit wt rere statea 110 220 v 60 60 TE rnar P cating acuatortox OOOO O OSS O e i ORs moion ontotSotware coron o ereen e Network cable oarso 75 Ti 08 25 maletormalscabe O Z Pfs eere OOO e O 2 2amprastacingiuess O O OO OOOO CT powers
7. rent Position 0 00 mm ii 0 00 mm 4 000 sec 0 000 sec Motion Parameters Linear Rotational Surrogate Inferior Superior Amplitude 0 Cycle Time Set Phantom Position A ea ot Surrogate Waveform Cos6 Amplitude 10 00 mm Cycle Time 4 000 sec Phase Shift 1 000 sec Average Position 3 78 mm Current Position 7 50 mm Tissue Simulation amp Phantom Technology z Import Motion Data Real time display of target and surrogate motion parameters Import data from column Smoothing 10 140 160 180 Import patient specific waveforms from tab delimited or comma separated file formats USER FRIENDLY MOTION CONTROL The CIRS Dynamic Platform is operated using CIRS Motion Control Software a user friendly graphical user interface that can be installed on any computer running Windows XP Amplitude cycle time and phase shift can be applied to both the surrogate and main platform using slider bars or by entering desired values within the limits of the system Five different waveforms are available from a standard pull down menu An unlimited number of clinically relevant and patient specific wave forms or correlation models can be imported from tab delimited or comma separated file formats There are also waveform editing smoothing and analyzing tools to ease the optimization of custom waveforms All motion files can be saved for future use The software also provides a
Download Pdf Manuals
Related Search
Brochure brochure brochure templates brochure meaning brochure examples brochure printing brochure maker brochure design brochure holder brochure templates free brochure printing near me brochure stand brochure paper brochure size brochure mockup brochure canva brochure ai brochure mockup free brochure online brochure png brochure 3 fold brochure menu brochure in english brochure vector brochure vs leaflet brochure meaning in english
Related Contents
Lochinvar TISUN SCH-I-O User's Manual FCC-Warnung Kanada Sicherheitsanerkennungen EN 55022 Samsung SPS-210 User Manual PATRIMOINE INDUSTRIEL ET TECHNIQUE Dometic DM2662 Refrigerator User Manual USER MANUAL - Kramer Electronics Astro Goya 590 South Shore Furniture 3642213 Instructions / Assembly Copyright © All rights reserved.