Home
A9GT-50WRS2/A9GT-50WRS4 type Serial
Contents
1. 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
2. whenever necessary Always forward it to the end user DESIGN PRECAUTIONS DANGER Do not bundle control lines or communication wires together with main circuit or power lines or lay them close to these lines As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS DANGER Before mounting or dismounting this module to or from the GOT always shut off GOT power Not doing so can cause a module failure or malfunction Before connecting the Communication cable to this module always shut off GOT power Not doing so can cause a malfunction INSTALLATION PRECAUTIONS CAUTION Use this module in the environment given in the general specifications of the GOT User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Insert the communication board securely into the GOT connector After it has been inserted check to make sure that it is not being lifted up A faulty connection can lead to faulty input or output When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to GOT or screw damage When mounting the communication board take care not to become injur
3. MITSUBISHI A9GT 50WRS2 A9GT 50WRS4 type Serial Communication Board User s Manual Thank you for buying the MELSEC GOT Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AIGT 50WRS2 RS4 U i 1DM113 IB NA 0800186 B 0406 MEE MITSUBISHI Graphics Operation Termina SAFETY PRECAUTIONS Always read before starting use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device Refer to the user s manual of the CPU module to be used for a description of the PLC system safety precautions These e SAFETY PRECAUTIONS e classify the safety precautions into two categories DANGER and CAUTION Procedures which may lead to a dangerous condition and DANGER cause death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and CAUTION cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it
4. discharge the electricity charged in the body etc before touching the module Failure to do so may cause a failure or malfunctions of the module DISPOSAL PRECAUTIONS CAUTION When disposing of the product handle it as industrial waste Manuals Relevant Manuals For relevant manuals refer to the PDF manual stored within the drawing software 2001 MITSUBISHI ELECTRIC CORPORATION 1 Overview This user s manual describes the A9GT 50WRS2 serial communication board hereafter referred to as the A9GT 50WRS2 A9GT 50WRS4 serial communication board hereafter referred to as the A9GT 50WRS4 Fitted to the A956WGOT the A9GT 50WRS2 A9GT 50WRS4 can be connected with the PLC CPU computer link unit microcomputer other s PLC or the like by using RS 232C RS 422 connector for peripheral The A9GT 50WRS2 is a communication board used for RS 232C communication The A9GT 50WRS4 is a communication board used for RS 422 communication A956WGOT AIGT 50WRS2 A9GT 50WRS4 For details of the system configuration refer to the GOT A900 Series User s Manual GT Works Version5 GT Designer Version5 compatible Connection System Manual After opening the box check that the following items are present Quantity A9GT 50WRS2 or AYGT 50WRS4 Communication board Mounting screw 2 Specifications 2 1 Specifications of the A9GT 50WRS2 A9GT 50WRS4 A9YGT 50WRS2 A9GT 50WRS4 9 pin D sub male inch screw 22 pit D sub e
5. ed by the components that are installed or surrounding materials When mounting the communication board remove any static electricity accumulated on your body before engaging in work Otherwise this may result in damage to the board WIRING PRECAUTIONS CAUTION Plug the communication cable into the connector of the connected module and tighten the connector mounting screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or module STARTUP AND MAINTENANCE PRECAUTIONS DANGER Before starting cleaning always shut off GOT power Not doing so can cause a module failure or malfunction CAUTION Do not disassemble or modify any module This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this module directly Doing so can cause a module malfunction or failure Always secure the cables connected to the module e g run them in conduits or clamp them Not doing so can cause module or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the module Doing so can cause module or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to
6. itsubishi Electric Europe B V German 6F No 105 Wu Kung 8rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg U K Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 ALEXANDRA ROAD 05 01 02 Italy Mitsubishi Electric Europe B V Italian MITSUBISHI ELECTRIC BUILDING Branch SINGAPORE 159943 Centro Dir Colleoni Pal Perseo Ingr 2 Tel 65 6473 2308 Via Paracelso 12 20041 Agrate B Thailand F A Tech Co Ltd i Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road Spain Mitsubishi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 10120 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBER MAKMUR Barcelona Spain JI Muara Karang Selatan Block A Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch Tel 62 21 663 0833 India Messung Systems Put Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M I D C BHOSARI PUNE 411026 TEL 33 1 5568 5568 Tel
7. lMmale Communication DDK brand meter screw connector Dee Sang 17LE 23090 27 D3CC 17L 10250 27 D3AC Internal current consumption DC5V mA weight g Ib 3 Name of the Parts and Outline Dimension Drawing f O4 3 A 3 A w 1 2 00 O 3 88 9 3 50 l Unit mm inch Description Communication cable Connector for connection of connection connector communication cable an O Connector Connector for connection to the GOT Communication board mounting 4 Installation Procedure 1 Open the slot cover on the back of the A956WGOT 2 Mount the A9GT 50WRS2 or the A9GT 50WRS4 in the slot for mounting a communication board Align the hole for the attachment screw on the transmission board with the hole for the attachment screw on the transmission board of the GOT main module then attach a Insert the AIGT 50WRS2 AIGT 50WRS4 3 Fix by tightening the mounting screws of the A9GT 50WRS2 or the A9GT 50WRS4 within the specified torque range 36 to 48 N cm 4 Close the slot cover To remove the unit reverse the installation procedure Be careful not to touch the board inside the GOT main body by hand when mounting the A9GT 50WRS2 or the AIGT 50WRS4 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in
8. the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation AV Paulista 1471 Conj 308 Instrumentation Plaza 103 Cao Bao Rd Sao Paulo City Sao Paulo State Shanghai 200233 China Brazil Tel 86 21 6475 3228 Tel 55 11 283 2423 Taiwan Setsuyo Enterprise Co Ltd Germany M
Download Pdf Manuals
Related Search
Related Contents
Comrac Archer Collection Gas Assisted Desk Mount This user manual describes all proceedings concerning the 取扱説明書はこちら ASSMANN Electronic AK-300202-050-E USB cable Manuel de la collecte digitale nn-s348wfrph User's Guide for Weather Research and Forecast (WRF) Modeling Omino Bianco pistolet.indd Accu-Chek Aviva Manual Central EU ファイバセンサアダプタ取扱説明書 Rev.55 Copyright © All rights reserved.
Failed to retrieve file