Home

Instruction Manual - E

image

Contents

1. not puncture cut shorten or splice the LED cable strip except where marked Unplug the unit and AC power adapter from the electrical outlet during electrical storms or when unused for long periods of time to prevent damage For outdoor use make sure that all connections and the end cap in the last segment are tightly secured to preclude the entry of water Do not exceed the recommended length of LED cable listed for each power supply Do not look directly into the LEDs when lit They are powerful and could damage your vision LOCATION Place power supply well above the ground or in an area they will NOT be submerged in water or other liquids The LED Cable strip and components are rated IP65 weatherproof only Do not submerge the LED cable strip in liquids or use the product in the vicinity of standing water or other liquids Keep all components away from extreme heat sources such as heating vents radiators electric heaters and re pits Do not cover this product as the covering may cause the LED Cable to overheat melt or ignite Do not submerge the LED Cable in liquids or use the product in the vicinity of standing water or other liquids Do not route the cord or LED Cable through walls doors windows or any like part of the building structure Place LED Cable strip so it will not shine directly into people s eyes INSTALLATION Safety measures must be observed at all times during the installation of this product Use proper safe
2. strips in a exible X shape End Cap Required to protect end of LED Cable that is not connected to a connector Female to Male Extension Allows for longer extension from power supply to rst run of LED Cable Available in 5 and 15 lengths Max 15 of extension per run Male to Male Extension Allows for longer extension in between runs of LED Cable Available in 5 and 15 lengths Max 15 of extension per run E CI368X01R0 Install Power Supply Install Inline On O Dimmer Switch optional Connect to Power Matching the icons on the connectors connect the Power Supply PS Link Connector to the Power Supply Plug the power supply into the AC outlet Connect Inline On O Dimmer Switch The Inline Dimmer Switch goes between the Power Supply PS Link Connector and the Power Supply Unplug the Power Supply from the AC outlet before connecting Match the icons on the PS Link Connector with the icons on the Inline Dimmer Mount Inline On O Dimmer Switch The Inline Dimmer uses a keyhole mounting system designed to be mounted vertically IMPORTANT Connect the power supply to the PS Link Connector BEFORE plugging the power supply into the AC outlet To select the correct power supply determine the length of LED Cable needed Wattage Max Cable Soft Output Max Cable High Output 18 watt 15 feet 6 5 feet 30 watt 25 feet 11 5 feet 60 watt 50 feet 23 feet 96 watt 82 feet 32 feet IM
3. LED FLEXIBLE CABLE STRIP LIGHTING Installation Instructions amp Quick Start Guide www e conolight com s a l e s e c o n o l i g h t c o m 8 8 8 2 4 3 9 4 4 5 PART NUMBER CI368X01R0 REVISED 08 22 2013 LED Cable Strip Dimension LED Cable Component Layout Inline On O Dimmer Switch Connectors Front view 30mm Side view 1 4 7 16 5 8 1 1 4 7 1 8 OR E 4 way Power Splitter PS Link Connector Power Supply AC Outlet Inline On Off Dimmer Switch optional PS Link Connectors End Caps End Cap U Connector X Connector L Connector T Connector I Connector Jumper Cable End Cap End Cap End Cap Front view Side view Back view 2 2 7 8 3 4 way Power Splitter Connects four LED Cable strips to one power supply Requires four PS Links Power Supply PS Connector One required for every run of cable Connects LED Cable to power supply Jumper Cable Connects two LED Cable strips together with a exible cable Available in 4 6 12 and 24 lengths I Connector Connects two LED Cable strips together in a straight line or extends a length of LED Cable L Connector Connects two LED Cable strips together at a right angle U Connector Connects two LED Cable strips parallel together for twice the brightness T Connector Connects three LED Cable strips in a exible T shape X Connector Connects four LED Cable
4. PORTANT Disconnect the Inline Dimmer from Power Supply before mounting IMPORTANT The Inline Dimmer can dim up to 50 feet max of LED Cable Power Button On Off Level 5 max shown Level 4 Level 3 Level 2 Level 1 min Light Bar Indicator Increase light level Decrease light level Dimming Bar A Screw partially into surface leaving 1 4 inch to hang the Inline Dimmer M2 9 4 screw is recommended provided by others B Fit center of keyhole in back of Inline Dimmer over screw and slide down to mount Cut LED Cable Cut the LED Cable strip to your desired length as indicated by the cut mark every 7 inches Installation Instructions amp Quick Start Guide Install Connectors optional A With the LED side facing up slide one LED Cable strip into the opening in one side of the connector until it reaches the end Repeat with the other LED Cable strips in the other sides of the connector if required At the end of your LED Cable run slide the End Cap onto the end of the strip that will not have a connector The End Cap protects the LED Cable strip B Push the LED Cable strip completely into the connector The ridges on each side of the LED Cable strip will be covered when the strip is properly installed C Using pliers apply even pressure to the bottom and top halves of the connector to push the connector together This secures the LED Cable strip inside Look for the ridges on each si
5. de of the LED Cable strip Slide LED cable until all of the ridges are covered IMPORTANT Only use connectors once Once LED Cable is inserted into connector removing LED Cable will damage the cable and connector IMPORTANT M2 9 4 screws are recommended provided by others Install 4 way Power Splitter optional Match the icons on each Power Supply PS Link Connector with the icons in the 4 way Power Splitter Repeat the same connection method with the Power Supply and the 4 way Power Splitter I Connector Channel Bracket Installs with one screw by others Barely visible after LED Cable snaps in Edge Bracket Installs with one screw by others Use for ush mount installations such as along a baseboard Channeling Installs with screws by others LED Cable snaps securely into place Install End Cap Mounting Options IMPORTANT The LED Flexible Cable Strip Lighting system is designed to work ONLY with the power supplies connectors mounting options and accessories listed Do NOT substitute other products as they may damage your system Do not plug into outlet until power supply is secured Place power supply near outlet and off the ground so there is no chance of it being submerged in water Risk of re and electric shock Uncoil LED Cable strip prior to plugging into receptacle The connectors consist of two parts a top and bottom which are partially assembled at the factory Do NOT push the conn
6. ectors together before you are ready to install The LED Cable strip may only be cut every 7 inches indicated by a cut line on the LED side of the strip When you are measuring for your installation if the total length in inches is not a multiple of 7 then adjust the plan of your layout to use the nearest cut line marked on the strip When using pliers that do not cover the entire surface of the connector hold the connector and strip steady so the LED Cable strip remains in position Carefully rotate the pliers and apply pressure to each side of the connector pushing the top and bottom together There is only one way to connect the 4 way Power Splitter Power Supply PS Link Connector to the Power Supply Make certain the icons match before connecting Connect the 4 way Power Splitter to the PS Link Connectors and to the Power Supply BEFORE plugging the power supply into the AC outlet Do not coil the strip into a tight circle with a diameter less than 8 inches ELECTRICAL RATING To avoid any malfunctions of the system and to protect against electrical shock re or physical injury please observe the following This system has been designed to work with 100 240 volt AC current Connection to a line voltage other than that may create a safety and re hazard and may damage the system If you are unsure of the type of power supply to your home consult your local power company or a quali ed service technician GROUNDING INSTRUCTIONS Th
7. is product must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor is able to result in a risk of electric shock Check with a quali ed electrician or serviceman if you are in doubt as to whether the product is properly grounded Do not modify the plug provided with the product If it will not t the outlet have a proper outlet installed by a quali ed electrician Ground Fault Circuit Interrupter GFCI protection should be provided on the circuits or outlet to be used for outdoor use of this product Receptacles are available with built in GFCI protection for this measure of safety If you are unsure of the type of outlet consult a quali ed service technician to install a GFCI receptacle POWER SOURCE Do not modify the plug provided with this product If it will not t the outlet have a proper outlet installed by a quali ed electrician Damaged or deformed power cords are hazardous and should be replaced immediately by a quali ed service technician OPERATION Do not operate with the LED Cable strip tightly coiled Do
8. riods of time the system should be unplugged from the AC outlet SERVICE Always remove the AC power adapter from the electrical outlet before adjusting or inspecting the system Inspect your system periodically Do not open dismantle or attempt to repair the LED Cable strip or the bottom half of the connectors There are no user serviceable parts Do not open the cabinets of accessories or power supply Opening the cabinets may present a shock hazard and any modi cation to the product will void your warranty Do not attempt to service the components yourself If water or any metal objects such as paper clips wire or staples accidentally fall inside then disconnect from the power source immediately and consult an authorized service center Technical data is based on optimum conditions and actual performance may vary 2012 e conolight All rights reserved Country of origin China U S Design Patent No D635 930 S Install Mounting Brackets optional Mark Placements for Brackets Install Edge Bracket Install Channeling Install Channel Bracket Installation Instructions amp Quick Start Guide 12 16 A B C A B A B Snap into lip Adjust placement if necessary when tightening screws www e conolight com IP65 N25615
9. ty gear and tools during the installation process to prevent physical injury Products should be installed in accordance with the user manual current electrical codes and or the current National Electric Code NEC Improper installation may cause a possible shock or re hazard To avoid electrical shock and or damage to the system do not handle the components with wet hands Always make sure the LED Cable strip is disconnected from the power source before cutting connecting mounting or modifying in any way Do NOT dismantle the LED Cable strip itself Do not coil the strip into a tight circle with a diameter less than 8 inches or bend it in half as it may damage the LEDs embedded in the LED Cable strip Do not subject the LED Cable strip to continuous exing Do not use if there is any damage to the light or cord insulation Inspect periodically LED Cable connectors have sharp pins inside Follow instructions when handling Use only e conolight LED Cable connectors mounting and power supply Carefully follow the instructions to install and mount Secure the LED Cable using only the hangers or clips provided Do not secure this product or its cord with staples nails or like means that may damage the insulation CLEANING Clean only with a dry or slightly damp cloth DO not use any acid or alkaline liquids cleansing agents or solvents Unplug the system from the wall outlet before cleaning NON USE PERIODS When left unused for long pe

Download Pdf Manuals

image

Related Search

Related Contents

  Fujitsu t900 User's Manual  EL PROWL-400 (PENDIMETHALIN) COMO CONTROLADOR DE  Rollei DF-S 500 SE  WHEATON Roller Apparatus  Graco Manzel Model 25 Lubricator User's Manual  2635 manual  Frigidaire FDG8970E User's Manual  CREATION D`UN GUIDE D`UNIFORMISATION DES PRATIQUES  SMG-700 User's Guide V1.00 (Nov 2004)  