Home

Classe LWB 12 - Red Lighting

image

Contents

1. 19 Blue LED array 3 0 255 Blue 0 Black 255 100 Blue 20 White LED array 3 0 255 White 0 Black 255 100 White Shutter strobe 0 31 Led trun off 32 63 Led turn on 64 95 Strobe effect slow to fast 8 8 6 96 127 Led turn on 128 159 Pulse effect in sequences 160 191 Led turn on 192 223 Random strobe effect slow to fast 224 255 Led turn on e Dimmer intensity 0 255 Intensity 0 to 100 Color Macro 10 10 48 0 7 No function 8 255 Color Rainbow from slow to fast Color Presets 0 10 No function 11 20 White2700k 21 30 White3200k 31 40 White4300k 41 50 White5600k 11 11 9 51 60 White6500k 61 70 White8000k 71 100 Blue Red 101 130 Blue Green 131 160 Green Red 161 190 Red Blue 191 220 Green Blue 221 255 Red Green Color Mode i2 li 10 0 189 No function 190 254 Edit a new white balance 255 Store a new white balance Chase Patterns 0 10 Led trun off 11 40 Chase 1 13 13 11 41 70 Chase 2 71 100 Chase 3 101 130 Chase 4 131 160 Chase 5 161 190 Chase 6 191 220 Chase 7 221 255 Chase 8 si lp Chase Speed 0 255 Fast to Slow Reset internal programs 0 79 Normal 80 84 All motor reset 85 87 no function 88 90 no function 91 93 Store white balance enabled 94 96 no function is lis lai 97 99 no function 100 119 Internal program 1 secne1 8 of EEPROM 120 139
2. Press lt Up Down gt the display will show Manual Control Press ENTER the display will show Manual Control The display show AUTO Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Un iR UN 8 5 3 Calibration With this function you can calibrate and adjust the effect wheels to their correct positions The password of calibrate values is 050 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Effect Adjust is displayed Press ENTER the display will show Effect Adjust Press lt Up Down gt the display will show Calibration Press ENTER the display will show Calibration The display show Password XXXX Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Un A WN 8 6 Users mode set In this menu user can select different channels list by different sequence For example after the user enter this manual if select Auto Program CH 22 means in this User s mode the Dimmer is in Channel 16 8 6 1 User mode With this function you can create user defined channel orders 8 6 2 Edit User Mode With this function you can adjust the rest user defined channel order 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Users mode set is displayed Press ENTER the display will show Users mode set 2 The display show Edit Us
3. WAS AARP V NEED SET SS Su E NE ZA A E N Ss 2 Sen S E gt eo S oF Ox A E WA EP PLA cS P AED Se p SOS Wm la N sd Mounting points Be sure this fixture is kept at least 0 2m away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Overhead mounting requires extensive experience including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury 5 DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket QR 1 Ground 2 Signal 3 Signal s E Eesi ES Eesi lt DMX512 DMX controller Address 35 Address 18 Address 1 6 DMX 512 connection with DMX terminator For installations where the DMX cable has to run a long dis
4. Auto Program is displayed Press ENTER the display will show Auto Program Tap the lt Up Down gt button the display will show Master1 Alone Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 1 5 Sound Control With this function you can run the internal program sound controlled 1 See QS Access the main menu Tap the lt Up Down gt button until Sound Control is displayed Press ENTER the display will show Sound Control Tap the lt Up Down gt button the display will show Master1 Alone Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 2 Information 8 2 1 Time information Current Time With this function you can display the temporary running time of the device from the last power on The display shows XXXX XXXX stands for the number of hours The counter is resetted after turning the device off l ied co IS Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Tap the lt Up Down gt button until the display will show Time Information Press ENTER the display will show Time Information Press lt Up Down gt the display will show Current Time Press ENTER the display will show Current Time The display will show XXXX Hours Press ENTE
5. Press ENTER the display will show Temperature C F The display show Celsius Press lt Up Down gt the display will show Fahrenheit Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Un A UN 8 3 6 Initial Status With this function Display initial effect position 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Press lt Up Down gt the display will show Initial Status Press ENTER the display will show Initial Status The display show XXX Press lt ENTER gt to confirm or press lt MODE ESC gt to return to the main menu nA A U N 8 3 7 Reset Default With this function you can select restore factory set for ON or OFF the default is OFF 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Press lt Up Down gt the display will show Reset Default Press ENTER the display will show Reset Default The display show OFF Press Up Down the display will show ON Press ENTER to confirm or press lt MODE ESC gt to return to the main menu nA A U N 8 4 Reset Function With this function you can reset the device via the Control Board You can select the different reset fun
6. is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Feedback Press ENTER the display will show Feedback The display show ON Press lt Up Down gt the display will show OFF Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Movement Speed With this function you can select scan mode from 1 to 4 p 4 5 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Movement Speed Press ENTER the display will show Movement Speed The display show Speed 1 Press lt Up Down gt the display will show Speed 2 Speed 3 Speed 4 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Mic Sensitivity With this function the default is 70 you can select the desired microphone sensitivity from 0 to 99 1 Unde Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality i
7. l qute ek Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Address via DMX Press ENTER the display will show Address via DMX The display show ON Press lt Up Down gt the display will show OFF Press ENTER to confirm or press lt MODE ESC gt to return to the main menu No DMX Status With this function when the drive is not DMX signal it runs automatism close hold and music the default is hold l ue 5 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show No DMX Status Press ENTER the display will show No DMX Status The display show Hold Press lt Up Down gt the display will show Close Auto Music Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Pan Reverse With this function you can reverse the Pan m
8. E LIEHTIMNE PROFESSIONAL MOVING HEAD USER MANUAL Classe LWB 12 KEEP THIS MANUAL FOR FUTURE NEEDS C C Contents 1 EEALUTES D M vseduae 1 VAR FixtuFe BAT RACER IL NR 2 3 SAFETY INSTRUCTIONS sisivscesssavsssscsdveccsvecvenssdedvaccussdvenssdadecssecseecssensocedeccseotscesdosstecsseasssestoesusesseccsceaseersees 2 3 1 Important safety Warns isccccesvcnsisesscectsesvcsesnscsnavcesdeestensvenstcectcesuenstsnasesscunsentstencsvecversusttbenassectessueedseness 2 3 2 GENERAL GUIDELINES wssiisccesscscsesssssccseteascsecsstecscesbescsecsesscsonsbebasnesededsuessdessaossvecdensscedseossseddensodedsexs 3 4 INSTALLATION INSTRUCTIONS wisscsscssccesssescocssesccescccnsncsodnssenssecbasseotnssestcosecovensessnesdedecssvedesanessecesssbecseaenss 4 rugis s 4 5 DMX 512 control connection eee eee eee ee eee eee etta oeste tna e ette anas e teens esee eaae ee senses seen aee eaae eet e enses sense eee 8 6 DMX 512 connection with DMX terminator eee e ee eee ee eee ee eee en esee eta see etas see eaa a esee eae sete enses teen aseo 8 7 Projector DMX start address selection 1 eere eee eee ee eee eren e eene tete seen setas etta ese ene sette setas etna eee 9 8 rn Un BTE TU RSEN TREE 9 6 1 FUNCTION eene es A E
9. Fine control of Pan movement TILT Movement 8bit 0 255 Tilt Movement 17 Tilt Fine 16bit 0 255 Fine control of Tilt movement Speed Pan Tilt movement 0 225 max to min speed 226 235 blackout by movement 236 255 no function Red LED allarrays 0 255 Red 0 Black 255 100 Red Green LED all arrays 0 255 Green O Black 255 100 Green Blue LED all arrays 0 255 Blue O Black 255 100 Blue White LED all arrays 0 255 White 0 Black 255 100 White 13 Red LED array 1 0 255 Red 0 Black 255 100 Red 14 Green LED array 1 i 0 255 Green O Black 255 100 Green 15 Blue LED array1 0 255 Blue O Black 255 100 Blue 16 White LED array1 0 255 White 0 Black 255 100 White 17 Red LED array 2 0 255 Red 0 Black 255 100 Red 18 Green LED array 2 0 255 Green O Black 255 100 Green 19 Blue LED array 2 0 255 Blue 0 Black 255 100 Blue 20 White LED array2 0 255 White 0 Black 255 100 White 17 Red LED array 3 0 255 Red 0 Black 255 100 Red 18 Green LED array 3 i 0 255 Green O Black 255 100 Green
10. Internal program 2 secne9 16 of EEPROM 140 159 Internal program 3 secne17 24 of EEPROM 160 179 Internal program 4 secne25 32 of EEPROM 180 199 Internal program 5 secne33 40 of EEPROM 200 219 Internal program 6 secne41 48 of EEPROM 220 239 Internal program 7 secne49 56 of EEPROM 240 255 Music Control secne of Program 1 10 prefabrication 10 1 Install Snoot Only fix four screws like the followings when install Snoot Fix four screws 10 2 Install frost filter Only fix four screws like the followings when install frost filter Fixfour screws 11 ERROR MESSAGE When you turn on the fixture it will make a reset at first The display may show Err channel is XX while there are problems with one or more channels XX stands for channel 1 2 3 4 5 6 who has the testing sensor for positioning For example when the display shows Err channel is Pan movement it means there is some error in channel 1 If there are some errors on channel 5 channel 6 channel 1 at the same time you may see the error message Err channel is Pan movement Err channel is Tilt movement Err channel is red led flash repeated for 2 times and then the fixture will generate a second reset If the fixture remain error message after performing reset more than 2 times only the channels which have errors can not work properly others can work as usual Please contact with dealer or manufacturer for service self repair i
11. Press ENTER to confirm or press lt MODE ESC gt to return to the main menu LastRun Password With this function you can display the timer password 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Tap the lt Up Down gt button until the display will show Time Information Press ENTER the display will show Time Information 2 Press lt Up Down gt the display will show LastRun Password 3 Press lt ENTER gt the display will show LastRun Password The time password is 038 4 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Clean Last Run With this function you can clear last run time of the fixture The display shows ON or OFF Press Enter to confirm l 4 5 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Tap the lt Up Down gt button until the display will show Time Information Press ENTER the display will show Time Information Press lt Up Down gt the display will show Clean Last Run At L Timer Password menu input right password Press lt ENTER the display will show Clean Last Run The display show OFF Press lt Up Down gt the display will show ON P
12. order to avoid a hazard CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals 3 2 GENERAL GUIDELINES This device is a lighting effect for professional use on stages in discotheques theatres etc the device was designed for indoor use only This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual Lighting effects are not designed for permanent operation Consistent operation breaks may ensure that the device will serve you for a long time without defects Do not shake the device Avoid brute force when installing or operating the device While choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust Please don t project the beam onto combustible substances The minimum distance between light output from the projector and the illuminated surface must be more than 0 2 meter If you use the quick lock cam in hanging up the fixture please make sure the quick lock fasteners turned in the quick lock holes correctly Operate the device only after having familiarized with its functions Do not permit ope
13. the settings of one channel will affect only the selected fixture In the case of the led move head which is a 17 channel fixture you should set the starting address of the first unit to 1 the second unit to 18 17 1 the third unit to 35 17 18 and so on 8 Control Board The Control Board offers several features you can simply set the starting address run the pre programmed program or make a reset MODE The main menu is accessed by pressing the button until the display starts flashing Browse through the menu by pressing the button 9 button button or button Press the Enter button in order to select the desired menu You can change the selection by pressing the the 2 button 9 button button or button Confirm every selection by pressing AC button You can leave every mode by pressing the button The functions provided are described in the following sections it will exit from flash 10 seconds after the last keypress Press this key under edit mode The functions provided are described in the following sections To access the display menu via the internal battery press the DC switch button for 2seconds To shut off the display immediately choose the commend Reset All menu and press Enter button otherwise the display will automatically switch off about 1 minute from last button press Effect Adjust Set Dmx Address A001 AXXX DMX a
14. to make the lights in good condition and extend the life time we suggest a regular cleaning to the lights 1 Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust 2 Clean the fan each week 3 A detailed electric check by approved electrical engineer each three month make sure that the circuit contacts are in good condition prevent the poor contact of circuit from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents Please refer to the instructions under Installation instructions Should you need any spare parts please order genuine parts from your local dealer 13 TECHNICAL SPECIFICATIONS Power supply AC100 240V 50 60Hz Power consumption 190 W Packing dimensions 48x42x36 5 cm Net weight 10 KG Gross weight 12 KG Remark errors and omissions for every information given in this manual excepted All information is subject to change without prior notice
15. A E E oe eia suono e Ve kae ek ve eene eee lt oa eve nose cuneo e eg po eoa Fe ee io ae A 11 M BTE eI RR n 11 BAD Diny Value vesscscssessssscessacsssscstescseasscscssesvecc oasacsesassuescsonscceccbessuccdsvesvedsvesteccssaseveddseseccesecssedseessocess 11 MERERETUR 11 SAA AUCO PEOSTAM data LR 12 8 1 5 CuuEbUOI Um E tototo 12 IVA LR TTE AE CR 12 8 2 1 Time information visicccsccssconssosscenscossenscessventocdesassessevesessnchacdesseuccedeesscesesouedsssseuteseocdsesseseonsssecnas 12 8 2 2 E Svcinivdiumom seris 5 soi 13 S323 T EI A sissccsccdscensecsscossncssceosecssvecsceseveesossenecssesscuedosssnsscosauetscessnetcoodecetesedsautssstocstsseseessseotoses 14 8 3 PERSONALITY REDE SEPTA 14 8 3 1 Status Set Unps oer rele nene ero eere venere rose Teresa eae ae Seas a E E easa eue n atat Suha SS 14 8 3 2 Service setting eere neku kuudeks taaa iaaeaie Eanes o inea eR so 16 8 3 3 Fans Controli muundama euo soros sS osok ussat sorsat osobe sesoses e Ue opise i 17 8 3 4 Display Stine sicecccseseessseevsesscesvensiscescedstcevensteesssedccestenisentececteestentbentsvestsederstcensseesdousesevenssenssers 17 8 3 5 Temperature CHB cccssecsciciesecressccsescecdescYeutuesessessecevensieoeteeseocersussvedoseseseseocsuscosestocesgecseecssesonsecs 18 REB POEINIETI CP T see seed 18 8 3 7 Reset Default qc 18 8 4 Reset FUNCUHON S
16. AS 18 8 5 DE TUZH LV CREE 19 S551 Test E aTa CE sivcccccscccsccnstcscconskosssvechoscguaccevesatesdensesessunvacecesnsecdesseuccecesetecsesonedssceenteseecsntsseceonssssecens 19 8 5 2 Manual COMtLONs i ccssisescsssssessssssscsssesseecssessesessescesssseosses scbdeossveveesss ootessdvectesseveutesteeecdesesveveesseeses 19 8 5 3 Calibra tioN ER 19 8 6 Users ODE SEL ASRPERDPEPIECE DEEP CE 19 SGP BET Quit sissies P E E T T A E A E 19 8 6 2 Edit Us r Mode rA 19 A D1 DV 0 OINEN N NNE N E E N E 20 8 7 1 Select DEOQFalWS eet eee eee eoe retra ene eere eor sessio seske nan eere euro opa ue ae intense sisevee sas vee 20 98 7 2 Edit DrOSraum ccsccokecctestecsaeccssecatiussosascacsesatecbecsessessecetecee Se St MAI 20 8 7 3 Edit SCENES TC oireista 20 8 7 4 REC Controller E LA 20 9 INSTRUCTIONS ON USE DP 22 LO prefabricati T 41 m es osis sen ieos t vsk een vu sioss iisa 24 IUS Install Bor P 24 10 2 Install frost filter cesccsssvescsssevessssosseesssonsescssonsiccsssssacsseoosacs vv siseive vas s vsevvneievs kes ekesiosioeskusv ekesed ends 25 EDENDI eo T ees 25 12 CLEANING AND MAINTENANCE e eee ee eene eee eo eet e etae sten eet en eee en ee eene eee en e eene seen eee en ee eene eene esaet 26 13 TECHNICAL SPECIFICAT IONS eere eene retenta onerat tata sonata stata tns on sins tn seats senten teneas sen
17. Address is displayed Press ENTER the display will show Tap the lt Up Down gt button the display will show A001 AXXX Press ENTER to confirm or press lt MODE ESC gt to return to the main menu With this function you can display the DMX 512 value of each channel The display automatically shows the channel with a value changing 1 Access the main menu PR 8 1 3 Slave Mode Tap the lt Up Down gt button until Dmx Value is displayed Press ENTER the display will show Tap the lt Up Down gt button choose each channel Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Dmx Value With this function you can define the device as slave 1 19 Access the main menu Tap the lt Up Down gt button until Slave Mode is displayed Press ENTER the display will show Slave Mode Tap the lt Up Down gt button the display will show Slave1 Slave2 Slave3 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 1 4 Auto Program With this function you can run the internal program You can select the desired program under Select program You can set the number of steps under Edit program You can edit the individual scenes under Edit scenes With this function you can run the individual scenes either automatically i e with the adjusted Step Time l te ok Access the main menu Tap the lt Up Down gt button until
18. D display after 2 to 59 minutes Turn the encoder in order to select the desired shut off time The default is 5 minute Display Reverse With this function you can the entire display to be flipped by 180 to allow for better view when the fixture is hung from truss or a ceiling This function is disabled as default 1 Tap lt MODE ESC gt button access the main menu Tap the Up Down button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Display Setting Press ENTER the display will show Display Setting 2 Press lt Up Down gt the display will show Display Reverse 3 Press lt ENTER the display will show Display Reverse 4 The display show OFF Press lt Up Down gt the display will show ON 5 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Key Lock With this function you can activate the automatic keylock status If this function is activated the keys will be locked automatically after exiting the edit mode for 15 seconds keeping press the MENU key for 3seconds if you do not need this function 1 nA RU P2 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Display Setting Press E
19. NTER the display will show Display Setting Press lt Up Down gt the display will show Key Lock Press ENTER the display will show Key Lock The display show OFF Press lt Up Down gt the display will show ON Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Disp Flash With this function you can the entire display to be flipped by 180 to allow for better view when the fixture is hung from truss or a ceiling This function is disabled as default 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the Up Down button until the display will show Display Setting Press ENTER the display will show Display Setting Press lt Up Down gt the display will show Disp Flash Press ENTER the display will show Disp Flash The display show ON Press lt Up Down gt the display will show OFF Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Un d UN 8 3 5 Temperature C F With this function Display the temperature for Celsius or Fahrenheit 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Press lt Up Down gt the display will show Temperature C F
20. R to confirm or press lt MODE ESC gt to return to the main menu Total Run Time With this function you can display the running time of the device The display shows XXXX XXXX stands for the number of hours l AD Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Tap the lt Up Down gt button until the display will show Time Information Press ENTER the display will show Time Information Press lt Up Down gt the display will show Total Run Time Press ENTER the display will show Total Run Time The display will show XXXX Hours Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Last Run Time With this function you can display last the running time of the lamp The display shows XXXX XXXX stands for the number of hours 1 Mode F9 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Tap the lt Up Down gt button until the display will show Time Information Press ENTER the display will show Time Information Press lt Up Down gt the display will show Last Run Time Press lt ENTER the display will show Last Run Time The display will show XXXX Hours
21. ce into operation for the first time These installations have to be approved by a skilled person once a year Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury CAUTION The electric connection must only be carried out by a qualified electrician Before mounting make sure that the installation area can hold a minimum point load of 10 times the device s weight Connect the fixture to the mains with the power plug Installation via the Omega holders 1 0mega holders 2 Clamp 3 Safety rope 4 Quick lock fastener a Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the D13 hole in the middle of the bracket b Insert the quick lock fasteners of the first Omega holder into the respective holes on the bottom of the device Tighten the quick lock fasteners fully clockwise c Install the second Omega holder d Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw Notice this step is quite important to ensure that the fixture will not drop out by the damage of the clamp Layout Drawings
22. ction you can call up various submenus via RDM This device is RDM ready RDM stands for remote device management and makes remote control of devices connected to the DMX bus ANSI E1 20 2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol Manual settings like adjusting the DMX starting address are no longer needed This is especially useful when the device is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX line The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices If DMX splitters are used and RDM control is to be used these splitters must support RDM The number and type of RDM parameters depend on the RDM controller being used 8 3 3 Fans Control With this function you can set the speed of the running fans The selections have Auto high and low 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality 2 Press lt Up Down gt the display will show Fans Control 3 Press lt ENTER the display will show Fans Control 4 The display show Auto Press Up Down the display will show High Low 5 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 3 4 Display setting Shut off time With this function you can shut off the color LC
23. ctions by turning the encoder 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Reset Function is displayed Press ENTER the display will show Reset Function 2 The display show Reset Pan amp Tilt Press Up Down the display will show Reset Pan amp Tilt 3 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 6 5 Effect Adjust 8 5 1 Test channel With this function you can test each channel on its correct function 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Effect Adjust is displayed Press ENTER the display will show Effect Adjust 2 Press lt Up Down gt the display will show Test Channel 3 Press ENTER the display will show Test Channel 4 The display show AUTO Moving frist channel Press lt Up Down gt can choose other channel 5 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 5 2 Manual control With this function you can adjust the lamp more easily All effects will be canceled the shutter opens and the dimmer intensity will be set to 100 With the individual functions you can focus the light on a flat surface wall and erform the fine lamp adjustment 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Effect Adjust is displayed Press ENTER the display will show Effect Adjust
24. ddress setting E Dmx Value ALL DMX value display 2 Slave Mode Slavel Slave2 Slave3 Slave setting E Auto Program Master Alone Auto program Sound Control Master Alone Music control Current Time XXXX Hours Power on running time Total Run Time XXXX Hours Fixture running time E Time Information Last Run Time XXXX Hours Fixture Last times clear E LastRun Password Password XXX Timer Password 038 Clean Last Run ON OFF Clear Fixture Last time D Temperature Info Head Temp XXX Q F Temperature in the head Software Ver V1 0 Software version Addr via DMX ON OFF Add via DMX No DMX Status Close Hold Auto Music Auto run if no DMX Pan Reverse ON OFE Pan Reverse movement Tilt Reverse ON OFE Tilt Reverse movement Pan Degree Pan 540 Pan Degree Select 1 Pan 540 90 offset Pan Degree Select 2 Status Settings Pan 630 Pan Degree Select 3 Tilt Degree Tilt 270 Tilt Degree Select 1 Tilt 240 Tilt Degree Select 2 Feedback ON OFF Movement Feedback Movement Speed Speed 1 4 Movement Mode Select fa Mic Sensitivity 0 99 Sensitivity of Mic E Hibernation OFF 01M 99M OFF Stand by Mode 2 Service Settin Service Pass Password XXX Service Password 050 A 8 RDM PID XXXXXX RDM PID Code Auto Fans Control High Fans Speed select Low Shutoff Time 02 60m 05m Display shutoff time Display Setting Display Reverse ON OFF Reverse 180 degree Key Lock ON OFF Key Lock Disp Flash ON OFF No Signal Flash Celsius Temperature switch cepa Fahrenheit betwe
25. e unit receives Auto Program Part 2 To start a Auto Program please proceed as follows 1 Slave Setting Select Function Mode by turning the encoder Press the Enter button to confirm Select Set to slave by turning the encoder Press the Enter button to confirm Turn the encoder to select Slave 1 Slave 2 or Slave 3 Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu 2 Automatic Program Run Select Function Mode by turning the encoder Press the Enter button to confirm Select Auto Program by turning the encoder Press the Enter button to confirm Turn the encoder to select Master or Alone The selection Alone means Stand Alone mode and Master that the device is defined as master Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu 3 Program selection for Auto Pro Part Select Edit program by turning the encoder Press the Enter button to confirm Select Select programs by turning the encoder Press the Enter button to confirm Turn the encoder to select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and thus select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press the Enter button to confirm Press the MODE ESC button in order to return to
26. en C F Initial Status PAN XXX Initial effect position Reset Default ON OFF Restore factory set 9 Reset ALL Reset ALL E Reset Pan Tilt Reset Pan Tilt Test Channel AUTO Test function Manual Control ns TAS Fine adjustment of the lamp Calibration Calibrate Password Color wheel XXX Password 050 Calibrate and adjust the effects to standard right position Standard Mode Basic Mode Extended Mode Users mode to change E Deer Noe User Mode A channel numbers gt 3 User Mode B E User Mode C Edit User ModeA Max Channel XX Edit User ModeB PAN CHOI Preset User modes Edit User ModeC Select Program Prog Part 1 Program 1 10 Program 1 Prog Part 2 Program 1 10 Program 2 Prog Part 3 Program 1 10 Program 3 Select programs to be run Edit Prg Program 1 Program Test Testing program Edit Program d Step 01 SCxxx Program in loop Program 10 Step 64 SCxxx Save and exit Edit Scene 001 pr Xr Save and automatically i Fade Time Edit Scenes Edit Scene i return Secne Time i 250 manual scenes edit Input By Out Rec Controller XX XX Automat scenes rec Default settings shaded 8 1 FUNCTION 8 1 1 Set DMX Address With this function you can adjust the desired DM X address via the Control Board 1 Access the main menu noni Vu 8 1 2 Dmx Value Set DMX Address Tap the lt Up Down gt button until Set DMX
27. ept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class I Therefore it is essential that the device be earthed If protection screen lens or ultraviolet screen in the fixture is apparently damaged or is damaged to exceed their own effective degree such as cracked and gashed it must be replaced The electric connection must carry out by qualified person Make sure that the available voltage is not higher than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project the beam onto combustible substances If the external flexible cable or cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in
28. er Mode frist channel Press lt Up Down gt the display will show Edit User Mode 3 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 6 7 Edit programs 8 7 1 Select programs With this function you can select the program for the Program Run 8 7 2 Edit program With this function you can edit the internal programs 8 7 3 Edit scenes With this function you can edit the scenes of the internal programs 8 7 4 Rec Controller The moving head features an integrated DMX recorder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head Excursion A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slav
29. he lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Pan Degree Press lt ENTER the display will show Pan Degree The display show 540 Press lt Up Down gt the display will show 630 540 90 offset Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Tilt Degree With this function you can select pan degree for 630 or 540 l Hd ip p Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Tilt Degree Press ENTER the display will show Tilt Degree The display show 270 Press lt Up Down gt the display will show 270 240 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Feedback With this function you can feedback switch of pan movement or tilt movement ARO Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality
30. ilt movement is adjustable Scan position memory auto reposition after unexpected movement Strobe effect with 18 flashes per second and pulse effect General dimming and blackout for all four colors Excellent color mixing and rainbow effect Display Can be changed 180 reverse to fit for different installation position e Dimmer intensity from 096 10096 Control board with full color LCD graphic display and touch keyboard Rechargeable Back up Battrty for Display Preset program 7 built in programs can be called up via DMX controller Software upload by optional accessory via DMX line 2 Fixture Overview Lens DC Switch Microphone Display Mode Esc button ENTER button Left button Down button O WAN OQ tn A N Up button 10 Right button 11 Power switch 12 Fuse 13 Power in 14 Power out 15 3 Pin DMX out 16 3 Pin DMX in 498888 3 SAFETY INSTRUCTIONS 3 1 Important safety warns CAUTION Be careful with your operations With a dangerous voltage you can Suffer a dangerous electric shock when touching wires This device has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not acc
31. ovement l SP wets Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Pan Reverse Press ENTER the display will show Pan Reverse The display show OFF Press lt Up Down gt the display will show ON Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Tilt Reverse With this function you can reverse the Tilt movement l Cic o b9 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Tilt Reverse Press ENTER the display will show Tilt Reverse The display show OFF Press lt Up Down gt the display will show ON Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Pan Degree With this function you can select pan degree for 630 or 540 l De 5 Tap lt MODE ESC gt button access the main menu Tap t
32. ration by persons not qualified for operating the device Most damages are the result of unprofessional operation Please use the original packaging if the device is to be transported For safety reasons please be aware that all modifications on the device are forbidden If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to short circuit burns electric shock lamp explosion crash etc 4 INSTALLATION INSTRUCTIONS CAUTION Do not operate this device with open cover 4 1 Mounting the device CAUTION AN Please consider the G B7000 1 2007 G B7000 217 2008 and the other respective national norms during the installation The installation must onlv be carried out bv qualificd person The applicable temperature for the lighting is between 10 C to 45 C Do not use the lighting under or above the temperature The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate safety rope Never stand directly below the device when mounting removing or servicing the fixture The operator has to make sure the safety relating and machine technical installations are approved by an expert before taking the devi
33. ress ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 2 2 Temperature Info Head Temp With this function you can display the temperature on the display board of the base near CM Y filter in Celsius l gestis M SES Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Tap the lt Up Down gt button until Temperature Info is displayed Press ENTER the display will show Temperature Info Press lt Up Down gt the display will show Head Temp Press ENTER the display will show Head Temp The display show XXX C P Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 2 3 Software Ver With this function you can display the software version of the device l GIG du ooa Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Information is displayed Press ENTER the display will show Information Press lt Up Down gt the display will show Software Ver Press ENTER the display will show Software Ver The display show Ver x x Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 3 PERSONALITY 8 3 1 Status settings Addr via DMX With this function you can adjust the desired DMX address via an external controller
34. s displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings Press lt Up Down gt the display will show Mic Sensitivity Press ENTER the display will show Mic Sensitivity The display show 70 Press lt Up Down gt the display will show 0 99 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu Hibernation Standby mode The lamp and step motors will be power off if the fixture stay without DMX signal for 15 mins Factory default And the fixture will be reset before working once it receive DMX signal again 1 Tap lt MODE ESC gt button access the main menu Tap the lt Up Down gt button until Personality is displayed Press ENTER the display will show Personality Tap the lt Up Down gt button until the display will show Status settings Press ENTER the display will show Status settings 2 Press lt Up Down gt the display will show Hibernation 3 Press lt ENTER gt the display will show Hibernation 4 The display show OFF Press Up Down the display will show 01M 02M 99M 5 Press ENTER to confirm or press lt MODE ESC gt to return to the main menu 8 3 2 Service setting Service Pass The Password for this function is 50 RDM PID With this fun
35. s not allowed PAN movement Er PAN yoke movement error This message will appear after the reset of the fixture if the yoke s magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB The PAN movement is not located in the default position after the reset TILT movement Er TILT head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB The TILT movement is not located in the default position after the reset 12 CLEANING AND MAINTENANCE The following points have to be considered during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Crs CAUTION Disconnect from mains before starting maintenance operation In order
36. sensa ens en suo 26 Thank you for your patronage We are confident that our excellent products and service can satisfy you For your own safety please read this user manual carefully before installing the device In order to install operate and maintain the lighting safety and correctly We suggest that the installation and operation should be done by the verified technician and follow the instruction strictly CAUTION Keep this device away from rain and moisture CAUTION Unplug mains lead before opening the housing Every person involved with the installation operation and maintenance of this device has to be qualified follow carefully the instructions of this manual INTRODUCTION Thank you for having chosen this professional moving head You will see you have acquired a powerful and versatile device Unpack the device Inside the box you should find 1 One XLR connection cable 2 Two omega clamps 3 One safety rope 4 Manual Please check carefully that there is no damage caused by transportation Should there be any consult your dealer and don t install this device 1 Features e 12 x 15W high power LEDs Extremely Long Life 50 000 Hr and low power consumption 3 DMX channel mode 15 17 21 channels Pan tilt movement 8 bit and 16 bit resolution For smooth and precise resolution Pan 540 630 540 90 offset optional Tilt 270 240 movement High speed of pan tilt movement speed of pan t
37. tance or is in an electrically noisy environment such as in a discothegue it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 1209 ON PIN 3 PIN 2 7 Projector DMX start address selection AII fixtures should be given a DMX starting address when using a DMX signal so that the correct fixture responds to the correct control signals This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device You can set the same starting address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to listen to the same control signal from the same channel number In other words changing the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on the quantity of control channels of the unit That means changing
38. the main menu 4 Program selection for Edit Program Select Edit program by turning the encoder Press the Enter button to confirm Select Edit program by turning the encoder Press the Enter button to confirm Turn the encoder to select the desired program With this function you can edit specific scenes into a specific program Press the Enter button to confirm Press the MODHESC button in order to return to the main menu 5 Automatic Scene Recording Select Edit program by turning the encoder Press the Enter button to confirm Select Edit scenes by turning the encoder Turn the encoder to select the desired scene numbers You can program a maximum number of 250 Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture Part 1 e seme soonest sommere seone te Part 2 es s ms m j 9 INSTRUCTIONS ON USE DMX channel s functions and their values 2IDMX channels Mode Channel Value Function St Ba Ex 5 5 1 PAN Movement Sbit 0 255 Pan Movement 16 Pan Fine 16bit 0 255