1. 5 Press to update with new date setting or press Es to abandon this option and retum to Usermenu 2 Setup Users 2 4 There are 31 usercodeswhich maybe assigned to one of the usertypes shown below User01 is designated asthe masteruserand isprogrammed as5678 atthe factory Although user01 can change theirpasscode the usertype cannotbe changed Once the masteruserhas assigned a userto the system they may also change their passcode but they cannot change their user type Master User02 31 canbe programmed asthe type Master If the installation company has programmed the masteruserforfull access he orshe will have access to all user menus and options If the installation company has programmed the masteruser for limited access he or she will NOThave access to Usermenu 2 options 6 and 8 and all of User menu 3 Standard Users02 31 canbe programmed asthe type Standard Thisusertype can only access User menu 1 Holiday Users 02 31 can be programmed as the type Holiday This usertype allows the alarm system to be set and unset and access to User menu 1 However the passcode is automatically deleted from the system when a master user passcode is used to unset the alam system Normally the master user would assign this passcode type a temporary user whilst the they are away on holiday etc 25 User Menu 2 TS790 amp T5900 User Manual Setup Users Cont Set Only Reset Only Duress
2. 28 TS790 amp TS900 User Manual User Menu 2 3 Press B to toggle between Amed and Omitted If a low tone is generated Coy 8 8 when pressing B then the selected circuit cannot be programmed into the 24Hr group 4 Repeat from step 2 for other circuits when finished press to abandon this option and retum User menu 2 Print System Log 2 7 The system log stores 700 events 1800 when expanded ifa printeris connected to the system it is possible to printa selected number of events Once the printout has been started itcan only be stopped by selecting this option again and entering O00 for the number of events 1 Ensure that User menu 2 is selected LCD Starburst LED re annt System Log REES ER ea R S N Ho events option The display will show 2 Enterthe numberof eventsto be printed 000 699 0000 1799 if expanded e g enter 150 forthe last 150 events starting with the most recent event The display will show 3 Press to start printing the display will automatically retum to User menu 2 To Cancel printing repeat from step 1 and select 000 0000 if expanded events at step 2 I amp Ifthe printerisleftconnected to the system it will printout system eventsasand when they occur real time printout 29 User Menu 2 TS790 amp T5900 User Manual Configure Wards 2 8 The 15790 amp T5900 can be split into four wards System Ward S Wa
3. 3 Press 0 to select the Ward Selection Menu The display will show FEES PARURE 4 Select deselectthe wards by pressing A for Ward A B for Ward B C for Ward C 0 for Ward S e g to set wards Band C deselect wards Sand A The display will show 5 When the display shows the required wards press The exit sounder will start if required leave via the prescribed ext route The display will show the remaining exttime LE 6 Whenexttone stopsthe displaywillshow Mass sr Bei PART SET the wards thatare set and the e g 85 38 Sun 28 APR ART SET lt gt The Ward Selection Menu isdisplayed fora pre programmed amountof time which is programmed bythe installation company If no wardsare deselected atthe end ofthe pre programmed time the alarm system will attempt to full set 13 Operating The System TS790 amp TS900 User Manual Unsetting individual Wards with Standard User Passcodes If the installation company has configured the alarm system as described on the previouspage the standard and master users will be given access to the Ward Selection Menu when unsetting the alarm system The following example shows how to unset wards A and B 1 Enter the premises via the prescribed entry route and proceed directly to the Starburst LED LCD generate an intemupted tone The display sacra a ae will show the remaining entry time the entytmerexpics Te dplayilshow EREN the entrytimerexpires Th
4. 45 Display Messages Cont 0 06 eee ee 46 Glossaty Of Terms iss oboe rh RR E ee cae bone ve 47 TS790 TS900 User Manual Overview Introduction The T5790 and TS900 are advanced security alarm contol systems using state of the art electronics to provide comprehensive but flexible protection for both domestic and commercial premises The system comprises of a number of components linked to a central control unit which is concealed from view but accessible for maintenance The T5790 can monitor from 10 to 16 detection circuits whereas the TS900 can monitora maxmum of 56 Both systemscan be operated from up to fourremote keypads which may be one of fourtypes Detection devices such as door contacts or movement sensors are allocated to detection circuits which are identified on the remote keypad displays All detection circuits may then be allocated to the whole system orgrouped into Wards areas so that access to certain areas can be controlled independently A modem can also be connected to the alarm system via the telephone line to allow remote interrogation programming and resetting of alarms Thisfeature is known as Downloading and is normally performed by the installation company orcental station Each alam installation is specific to the site and its occupier and may differ from other TS790 TS900 installations This manual describes in detail all the functions and procedures available to the user however notall these maybe
5. Set Bx SEI 3 When the display shows the required ward s press The exitsounderwill start if j j 1 T Please Exit Hou mnc The display will showthe remaining exttime 4 When the system has set the display will show the wards that are set and the time Unsetting ward B with Code Set Group A passcode System initially full set 1 Enter the premises via the prescribed entry route and proceed directly to the remote keypad The intemal sounders cal als tD LCD will show the remaining enty time 2 Enteryourpasscode IN before Fass 3 Select the wards you require to unset 4 When the display shows the required wards press The entry sounder will stop and the display will show the wards that are ee i 16 TS790 amp TS900 User Manual User Menu 1 User Menu 1 Introduction User menu 1 is only available to selected users the menu is selected by entering your passcode and pressing the ENT button within 5 seconds There are thirteen menu options which can be selected in any order To leave User menu 1 and retum to the system to the normal unset condition simply press the ESC button To select User menu 1 enter your passcode 2 2 2 2 then press the E button within 5 seconds The display shows RJ 5 Bell Test page 18 IN Walk Test page 18 le Remote Reset page 19 4 Change Passcode page 19 5 Enable Chime page 19 16 Omit 24 Hou
6. Front Door etc Once the edit circ uittextoption isselected the keypad operates ina tex mode see page 44 for full details To program circuit text proceed as follows LCD 1 Ensure that User menu 3 is selected Press 6 to select the Edit Circuit Text option The display will show p 2 Select the circuit by entering its numberorby pressing A To scroll up one circuit C To scroll down one circuit e g to select circuit 04 enter 04 If CCT 84 the circuit has no tex the display will show 3 Press B if text has already been programmed for the selected circuititcan now be edited go to step 6 However if the circuit has no text the display will show 4 To program new tex without copying press and go to step 6 If you wantto copytext from anothercircuit select the circuit by entering its numberorby pressing A To scroll up one circuit B To scroll up ten circuits C To scroll down one circuit e g to copy tex from circuit 02 enter 02 The display dde us will show the text to be copied e g 5 Press to copy the text and edit as below The display SSSR will show the copied text e g CT B2 6 Use the keypad keys to program edit the text see page 44 When the display shows the required text press to acceptand repeat from step 2 orpress J to abandon and retum to Usermenu 3 42 TS790 amp TS900 User Manual User Menu 3 View Inactive Circuits 3 0 The T5790 and T5900
7. Time Switch B TU Off Line 1 Baa pare bal hal Time Switch B 300 ff time 1 1800 LLLI Time Switch B TIM Select Ortion mo ERLE Starburst LED TIME ote 37 User Menu 3 TS790 amp TS900 User Manual Setting The Day Forthe Time Switchesto operate on the corect daysthe system requires the day to be entered This will also be displayed on the bottom line of LCD remote keypads Set the day as follows 1 Ensure that the required Time Switch is LED Starburst LED selected e g Time Switch B The display will show 2 Press amp to set the day The display will show man nI press 4 to select the day Wednesday The Cv DET display will show 4 Press E to accept the setting the display will show Manually Switching The Output The Time Switch output may be manually toggled On and Off as follows 3 Selectthe day by using keys 1 to 7 e g LCD Starburst LED a 20 5 Bst sekectsd e g Tm Switch B Te display will Select Ortion 1 Ne show status of the selected Time Switch e g 3 Press the 0 key to toggle the selected fine Suiten E DN Time Switch output ON and OFF e g to is 9 ot switch output on press 0 The display will show nn ee T Fe required press amp J again to retum to User Petes Setion s menu 3 38 TS790 amp TS900 User Manual User Menu 3 Part Set Groups 3 2 This option allows the Part Set buttons A Band C to be defined so that they can
8. electric door stike connected to the alarm system so that when the passcode is entered the door strike is operated to allow the user access into that area Users 02 31 may be programmed as Full Set Group This user type only allows the wards assigned by the installation company ormaster user to be set and unset This usertype does not have access to any user menus Users 02 31 canbe programmed as Code SetGroup A Thisusertype only allows the wards assigned by the installation company ormaster userto be set and unset This usertype does not have access to any user menus Users 02 31 canbe programmed as Code Set Group B Thisusertype only allows the wards assigned by the installation company ormaster user to be set and unset This usertype does not have access to any user menus Users 02 31 canbe programmed as Code SetGroup C Thisusertype only allows the wards assigned by the installation company or master userto be set and unset This user type does not have access to any user menus 26 TS790 amp TS900 User Manual User Menu 2 Setup Users Cont To setup users proceed as follows 1 Ensure that User menu 2 is selected Press 4 to select the Setup users option The display will show 2 Enter the user number 02 31 that is required to be setup e g to setup user 12 enter 12 followed by The display will show the curent user type Note If the code iscurmently unassigned the display will show Not in
9. gt 9999 I amp If Night circuits have been selected asomitted the alarm system MUSTbe setor part set from User menu 1 in order to invoke the omitted circuits 21 User Menu 1 TS790 amp T5900 User Manual Silent Set 1 8 This menu option allows the user to full set or part set the system silently whilst User menu 1 is selected This is an altemative procedure to the one described on page 10 LCD Starburst LED 1 Ensure that User menu 1 is selected i i ilent Set on ENT Press 8 to select the Silent Set option The Enter aroue gt 2L EIN display will show 2 The system can now be full or part set silently by pressing 0 for full set A forpart set A B forpartsetB C for partset C e g To full set the system press 0 and A Flease Exit How leave via the prescribed exit route The 2993 display will show View Activity Count 1 9 Detection circuits that have been programmed by the installation company as Flagged will increase the activity counterby one each time the circuit is activated when the system is unset The counter is automatically reset to zero when the system is full or part set and the counter is restarted when the system is unset This counter could be used to countthe numberof persons entering in to a particular area e g shop entrance door To view the counter proceed as follows LCD Starburst LED 1 Ensure that User menu 1 is selected activity opga nnnn Press 9 to
10. wards press The exit sounder will sat if ross TE required leave via the prescribed exitroute Time 1ert gt aa25 LILIE The display willshowthe remaining exttime 6 When the system has set the display will as per PART SET show the wards that are set and the time n5 un pa Da PT lt gt Ifthe system is partset entry of a valid passcode is assumed to unset rather than set further wards To set further wards it is necessary to unset nothing the system will then assume that you require to set further wards 1 ul Operating The System TS790 amp TS900 User Manual Setting amp Unsetting Wards with the Code Set Group Passcodes If the installation company has enabled the Ward Selection Menu for your alarm system all users defined as Code Set Group users will also have access to the Ward Selection Menu Howeverthe userscan onlyselectordeselectthe wardsthathave been assigned to their Code SetGroup e g if Code SetGroup A isconfigured to have accessto wardsAand B then when the Ward Selection Menu is displayed the usercan only select or de select wards A and B The following example uses Code Set Group A which is configured to have accessto wards A and B Setting ward B with Code Set Group A passcode system initially unset 1 Enter your passcode 2 2 the LCD Starburst LED display will show Please Confirm Set AB RB 2 Selectthe wards you require to set e g Eee
11. If an alarm has occured whilst the alarm system is full or part set the display will indicate the detection circ uit that wastriggered when the system is unset Once the cause ofthe alam has been established the system must be reset see Resetting after an alarm 1 Enter the premises or area via the LCD Starburst LED prescribed entry route and proceed directly to the remote keypad The intemal sounders will generate an intemupted tone The display will show how much time you have left e g 2 Enteryourpasscode 2 2 2 2 within pa CON the entrytime The intemal sounders will stop ALARM oF and the display will show the detection circuit that caused the alam e g 3 Referto Resetting after an Alarm gt _ If Circuit Tex hasbeen programmed then the display on the LCD and Starburst remote keypads will altemate between the Circuit number and the Circuit Text at step 2 Resetting After An Alarm The installation company will have programmed the system to be either User Reset Engineer Reset or Remote Reset consult your installation company if you are not sure User Reset From step 3 of Unsetting After An Alarm proceed follows Starburst LCD LED 1 Enter your passcode 2 2 2 The Press ent to EUNT display will show Select Functions Ve ea 2 Within 5 seconds press amp J The display SYSTEM OPEN n 3 After 5 Seconds the SYSTEM OPEN Fe AGA show the time date and banne
12. PA Code Access Full Set Group Code SetGroup A Code Set Group B Code SetGroup C Users 02 31 may be programmed as Set Only This user type allows the alarm system to be setand access to User menu 1 Users 02 31 may be programmed as Reset Only This usertype allows 24hralarmms to be reset and access to User menu 1 option 1 to 9 Users 02 31 can be programmed as Duress When this user type is entered a silent Panic Alarm i e Bell and sounders not triggered is transmitted to the central station via the telephone line and remote signalling device if fitted The user will still be able to setand unsetthe alarm system and access User menu 1 Note All other user code types will generate a Duress alarm if the passcode is entered with the first two digits reversed e g for a standard passcode of 2580 enter5280 to generate a Duress alam If required thisfeature can be disabled by the installation companyor by making the first two digits of the passcode the same Users 02 31 can be programmed as PA Code When this usertype is entered a Panic Alarm is transmitted to the central station via the telephone line and remote signalling device if fitted The extemal sounder s and strobe light s are also activated Users 02 31 can be programmed as Access When this usertype is entered any output thatis programmed as Access will activate fora pre set time Normally this user type is used in conjunction with an
13. full alarm will occur when the first entry timer expires lt gt Ifduring the entryprocedure the user straysfrom the prescribed entryroute and activates a detection circuit a full alarm will occur intemal sounders and extemal sounders If the alarm system is fitted with a remote signalling device such asa digicom this will also be triggered and police action will be taken However the alarm sytem may be programmed with an Entry Abort feature which will allow a further presettime delayto occur if a detection circuit isaccidentallytriggered during the entry procedure This will delay the triggering of the remote sgnalling device and allow the user time to unset the system The delay is normally set to 90 seconds by your installation company Full Set Entry Time Second Entry Time Part set Entry Time Entry Abort Delay TS790 amp TS900 User Manual Operating The System Part Setting Using The Part Set Buttons The T5790 amp T5900 can have up to three predefined part set configurations Each configuration allows the alarm system to set with one or more wards isolated Each configuration is then assigned to a part setbutton A BorC normally this will be done bythe installation company at the time of commissioning However the master user may also configure the partset buttons providing the installation company has programmed the alam system to allow this facility see Part Set Groups on page 39 To partset the a
14. have a facility to flag selected detection circuits that have not been activated whilst the system was unset This feature would normally be used in situations where a movementdetectorislikelyto become obscured bythe activityinthatarea Forexample boxes within a store room that are stacked in front of a detector The system can still be full orpart set but the display will show those detection circuits that ha ve not been activated whilst the system was unset The master usercan use this menu option to view the inactive detection circuits lt gt Only detection circuits that have been programmed as Flagged by the installation company will provide this feature To select the View Inactive Circuits option proceed as follows 1 Ensure that User menu 3 is selected LCD 1 i i Ho Activity from Press 0 to select the View Inactive C irc uits option The display will show those circuits Starburst LED which have not been activated whilst the Stores Detector Git peat CCT 82 Healthy DEI U J system has been unset e g 2 Press J to abandon and retum to User menu 3 43 User Menu 3 TS790 amp TS900 User Manual Text Keypad In the text mode the keypad functions as follows A Up the alphabet 1 CharacterA 2 CharacterE 3 Character B Change cursor 4 Charactero 5 CharacterU 6 Numbero C Down the alphabet 7 Curorleft 8 Toggle case 9 Cursor right D Notused ent Accept text 0 Space s Abandon editing
15. is unset This menu option allows the user to temporarily omitthe circuits thathave been assigned in the 24 Hourgroup This will allow them access to the areas that are protected by 24Hr and Auxiliary type detection circuits e g Loading bay doors Fire Doors etc LCD Starburst LED 1 Ensure that User menu 1 is selected ALIS Press 6 to select the Omit 24 Hour Group option The system remains unset and the OMITTED display will show 2 To re reinstate the 24 hourGroup repeat SYSTEM OPEN DPEN step 1 The display showthe SYSTEM OPEN message I amp Ifa low tone is generated when this menu option is selected then no detection circuits have been assigned to the 24 Hour Group Omitting Circuits 1 7 Sometimes it may be necessary to omit detection circuits when setting or part setting the system This allows the useraccess to the omitted area s when the system is set orpartset It is also possible to omit 24hr or Auxiliary circuits so that access to these areas can be obtained when the system is unset When the alam system is unset or when a user passcode is entered Night detection circuits thatwere selected asomitted are automatically re reinstated Only detection circ uits thathave been programmed by the installation company as Omit may be selected when using this menu option 20 TS790 amp TS900 User Manual User Menu 1 1 Ensure that User menu 1 is selected Press 7 to select the Omit Circuits option The d
16. relevantto the way yoursystem is setup To avoid unnecessary operating enors please discuss the details of the alarm system with your installation company before attempting to use it Also ensure that installation company complete the system record sheets at the back of this manual and fill in the details required within the section called Operating The System Overview TS790 TS900 User Manual Remote Keypads Youralarm system can be operated from one ormore remote keypads which will have been strategically located within the protected premises The remote keypads may be one of four types Arming Station The remote aming station can only be used to full set part set and unset your alarm system Green Power Indicator Flashes if no mains power is present Steady when mains poweris present e Red Function Indicator Can be O programmed by the alam company to indicate a fault set or part set etc Keyboard Used for operating your alam system O Cover Fold down cover with quick guide operating instructions Setting the System em ent o ec LED Keypad The LED remote keypad can be used to full set part setand unset the alarm system Italso can be used forlimited programming functions LED Display Used to show the system un time along with other system o lt lt OPE D as Be messages A Green Power Indicator Flashes if no mains powe
17. select the View Activity Count option The display shows the count value e g 2 Press J to abandon this option and retum to User menu 1 Full Set and Part set 1 0 A B C This menu option allows the user to full or part set the system from User menu 1 as follows 1 Ensure that User menu 1 is selected The system can now be full or part set by pressing 0 for full set A for part set A B for part set B C forpart set C e g To full set the system press 0 and 5999 leave via the prescribed ext route The display will show 22 TS790 amp TS900 User Manual User Menu 2 User Menu 2 Introduction This menu is only available to master users and is selected by pressing the ENT button whilst User menu 1 is selected There are eleven menu options within this menu which may be selected in any order The master user may leave this menu and retum to User menu 1 by pressing ESC button oradvance to User menu 3 by pressing the ENT button To select User menu 2 first ensure User menu 1 is selected then press the I key The display shows 1 View Circuits page 24 2 Set the Clock page 24 3 Set the Date page 25 4 Setup Users page 25 5 Alter Chime Circuits page 28 6 Alter 24Hr Group page 28 1 Print System Log page 29 8 Configure Wards page 30 9 View System Log page 31 0 Remote Call Back page 33 AJ Initiate Remote Service Call pag
18. set any combination of wards S A Band C e g Button A can be defined to set wardsA and B and Button B defined to setonly ward B Each Partset Group may also have up to 32 charactersof text assigned See Edit Text For Part Set Groupson page 41 The following example shows how to define Part set Group A Button A so that wards SA amp C are set when the button is selected by the userattime of setting 1 Ensure that User menu 3 is selected RS GRP option The display will show 2 Selectthe Part set group by pressing A for Part set Group A B for Part set Group B C for Part set Group C A The display will show WO nr 3 Select de select the wards that will set when the Part set group is selected by pressing 0 To select de select Ward S A To select de select Ward A B To select de select Ward B C To select de select Ward C e g To select the Ward S and Ward uni um n Part t Gi A C Press O then C The display will 5A show 4 When the display shows the required setting press v to accept The display will retum to step 1 Repeat for other part set groups B or C orpress 9 to retum to User menu 3 ri Part Set Group Operation When a Master or Standard user passcode is entered during the unset mode the alam system will attemptto fully set aftera five second delay However if during the five second delay one of the pa
19. the test The display will showthe remaining on time e g Bells ON gt 89 Press ESC to end 5 The display will automatically retum to User menu 1 when all three tests are completed Walk Test 1 2 This option allows the userto test the function of individual detection circ uits without causing an alam As each cir uitis activated the circuit numberand status are displayed and the intemal sounders generate a two tone Chime sound Once the test has been completed the tested circuits can be reviewed in numerical order 1 Ensure that User menu 1 is selected Press 2 to select the Walk Test option The display will show 2 Activate detection circuits in tum by opening doors with alam contacts and walking in front of movement detector e g activate circuit 05 then circuit 03 3 When the test has been completed press 4 he display will show 4 The display will now automatically scroll through the circuits that were tested in numerical order The curent status of the circuit is also displayed The button can be used to scroll through the tested circuits more quickly if desired 5 Press J to leave the Walk Test option and retum to User menu 1 Starburst ress E50 is end Test ress E50 is end ESC to end 5s x NONE x x coe ROTE Office Door CCT 85 Active Office Detector CCT 83 Active Tested CCTs were Press ESC to end Office Detector CCT 83 Healthy A Active H Healthy S Shorted
20. uts 2 1 oscil coe pace bere m ea are 24 SetClock 2 2 i ess kr engem a n stt paeem ra n 24 Set Date 2 3 ru 00 iia ced ade en aaa 25 Setup Wers 2 4 sae y x oe ha x EP x CR d da 25 Alter Chime Circuits 2 5 ros RETE REPRE ea ede be 28 Alter 24Hr Group 2 6 0 cc cece n III 28 Print System logs 2 7 5 a nahen m euim een 29 Configure Wards 2 8 30 Viewing the System Log with an LCD Remote Keypad 2 9 31 Viewing The Log With an LED or Starburst Remote Keypad 2 9 31 Remote Call Back 2 0 sse n IIR 33 Initiate Remote Service Call 2 A4 nnn 34 User Menu 3 Introduction iura esce erra ey ee y ned oe is 35 Time Switch A B amp C 3 1 isses nnn 36 Selecting Time Switches aonana auaa 36 Setting The On limes llsllsslssllsrnenee 36 Setting The Off limes 0 2 0 2c eee eee 37 Setting The Days Of Operation 00005 37 Setting The Day 0 ee 38 Manually Switching The Output 05 38 Part Set GroupS 3 2 0 teens 39 Gode Set Groups 3 3 4 ddan exter deaths e oe a 40 User Names T9900 Remote Keypads Only 3 4 41 Edit Text For Part Set Groups T5900 Remote Keypads Only 3 5 41 Edit Circuit Text T5900 Remote Keypad Only 3 6 42 View Inactive Circuits 3 0 lle IR 43 Tex Keypad inea km gan ana 44 Fault Finding Display Messages vex hp ox ra eee d
21. visit The system can still be used as normal but you should contact your installation company for further advice Another user is operating the system from a different remote keypad When he she has finished all remote keypads will revert to normal Tamperalam from detection circuit 05 Refer to Resetting After an Alarm on page 11 You are trying to set the alarm system with a telephone line fault LF If you press the system will continue to set or part set but your remote signalling device may not work if the alarm is triggered 46 T9790 amp T5900 User Manual Fault Finding Glossary of Terms Auxilia ry C irc uit Chime Central Station Detection Circuits Digicom Downloading Duress Exit Entry route Final Exit Entry Time Event Log Exit Time Exit Terminator Full Set Master User Modem Night C irc uit Omit Part Set Adetection circ uittype which is monitored atalltimes When triggered it will only activate outputs that are programmed as auxilia ry An optional facility which allows selected detection circuits to generate a two tone Chime when triggered A permanently manned monitoring station used to receive alam transmissions via the telephone line from a remote signalling device such as a digicom All detection devices e g magnetic contacts movement sensors etc are connected to detection circuits Each circuit is allocated a number which identifies the detection d
22. 1 Ensure that the required Time Switch is selected e g Time Switch B The display will show 2 Select the first second or third OFF times by pressing AJ for the first OFF time 5 for the second OFF time 6 for the third OFF time e g to select the first OFF time press 4 The display will show 3 Enter the OFF time in a 24Hr format e g for 6 00 PM enter 1800 The display will show aS 4 Press to accept the time setting The display will show 5 Repeat steps 2 3 and 4 forthe second and third OFF times as required Setting The Days Of Operation To setthe daysthatthe first second and third On and Offtimesoperate on proceed asfollows LCD Time Switch B Select rtion 1 Ensure that the required Time Switch is selected e g Time Switch B The display will show 2 Selectthe days of operation forthe first second orthird timer by pressing Z for the first timer 8 forthe second timer 9 forthe third timer e g press 7 to set the days of operation for the first ON OFF timer The display will show 3 Select de select the days of operation using keys 1 to 7 e g press 1 then 2 to select the days Sunday amp Monday etc The display will show 4 Pressen to acceptthe days of operation setting The display will show 5 Repeat steps 2 3 and 4 forthe second and third ON OFF times as required LCD Starburst LED Time Switch B CTUM Starburst LED LCD
23. 19 90 T5900 Intruder Alarm Control Panels User Manual Quick Reference Guide Full Set Enter your passcode AAC Part Set Enter your passcode Press A BorC as required 2224 A or B Unset Enter your passcode AAMC Silent Full Set Enter your passcode Press 8 3 9 2 7 8 Silent Part Set Enter your passcode Press A BorC as required Press 8 DDD A or B or C 8 Bell Test Enter your passcode Press ENT within 5 secs Press 1 sounders on Press ESC when finished MAA ev 4 ESC Walk Test Enter your passcode Press ENT within 5 secs Press 2 Conduct Walk Test Press ESC when finished soog ew 2 Conduct Walk Test ESC Remote Reset Enter your passcode Press ENT within 5 secs Press 3 12 02 023 2 ev 3 Contact your central station and quote 4 digit number Enter reply number Press ENT Press ESC when finished zoow ev ESC Change Passcode Overview Enter your passcode Press ENT within 5 secs Press 4 Enter new passcode Press ENT to accept Press ESC when finished JAG CONTENTS Quick Reference Guide Overview Intioduction isis eR RR Rense decane ae 1 Remote Keypad u a ceed eames cena naar 2 AMINI STATIONS e P EE 2 LED Keypad osi door COD cathe oup C oo ot eie EX Bebe E 2 Staiburt Keypad issus cides ga hn hex x ORDRE CR Rud 3 LCD Keypad
24. 4 FIRE ALARM B2 ERED 88 38 45 2804 IAE Lt FUSE BLOWN amp Tu MODE FUSE Bi B8 38 45 28484 MODE REMOVED Bl M nt 88 38 45 28 784 e NECI Lt Full alarm from detection circuit 05 Referto Resetting After an Alarm on page 11 Auxiliary or Bell tamper alarm Refer to Resetting After an Alarm on page 11 Auxiliary alarm from detection circuit 06 Referto Resetting After an Alarm on page 11 The system standby Battery is faulty Contact your installation company forfurther advice One ormore circuit have failed whilst on test Use the View Log option to view the detection circuits that have failed The system can still be set or part set Contact your installation company for further advice One ormor 24 hour circuits are isolated from the system Referto Omit 24 Hour Group on page 20 Code tamperfrom remote keypad 01 caused by 4 incorect passcode entries Refer to Resetting After an Alarm on page 11 Delayed alarm from detection circuit 05 Refer to Resetting After an Alarm on page 11 Entry time out alarm from detection circuit 01 Refer to Resetting After an Alarm on page 11 Fire alarm from detection circuit 02 Referto Resetting After an Alarm on page 11 The auxiliary supply fuse has blown Contact your installation company forfurther advice The auxiliary supply fuse in Node 01 has blown Contact yourinstallation company forfurther advice Node 01 has been disconnected from the system or
25. 42 44 sib ele RR Db RR DD peewee INR RES EE 3 Operating The System ajujefolt oivo o pr 4 ser Men s eR een 4 Engineeron Site Message 0 cece nennen 4 Full Setting The System ssseseee nenn nn 5 Unsetting The System 22222 eee seen een nenn 6 Part Setting Using The Part Set Buttons 22 222222 cee eee 7 Part Setting With Part Set PasscodeS 1 ce cece eee 8 Silent Sting ede oer ma xe pa EY ER Y EP E 10 Unsetting After An Alam lssseleeee nh 11 Resetting After An Alam ccc cece eee tenes 11 User Re SEC nie ane chase ane Face n claim ERAS OR 11 Engineer Reset ae ana chess 12 Remote Reset eios e bce bonuses at 12 Setting individual Wards with Standard UserPasscodes 13 Unsetting individual Wards with Standard UserPasscodes 14 Setting amp Unsetting Wards with the Code Set Group Passcodes 16 User Menu 1 IDOE UC TONG EPOR DE 17 Bell Test 1 1 00 000 p IRR RD ah 18 Walk Test 1 2 22 44 822 aaa tear oy PER nhaand 18 Remote Reset L3 hose Ra IET de eat 19 Change Passcode 1 4 2 2 2222 cece cece eee 19 Enable Chime L5 ics rau cheek oboe Rex aces ss 19 Omit24 Four Gup 1 6 oorr REIR 20 Omitting Circuits 1 7 seen 20 SlenESeE 1 8 5s 5 oa ane a dare cem Ion d et EE ac Eie 22 View Activity Count 1 9 0 0 0 0c cece cece nnne 22 Full Set and Part set 0ALBC 222 2222222 ee 22 User Menu 2 INDOUUCHON bees chee Ha a da 23 Mew Cic
26. Cursor Types This character is used to represent the top line text cursor V This character is used to represent the bottom line text cursor This characteris used to represent the number cursor To program text Proceed as follows 1 Text is entered by pressing one of the vowel keys and then using the A or C keysto move up and down e g to type the letter R press 5 to select U then press C three times to scroll down to the letter R The display will show 2 Now use the 9 key to move the cursor right repeat step 1 forthe nex letter Keep repeating steps 1 and 2 until the whole word is formed e g 3 Numbers may be entered by pressing key 6 then using the AJ or C keysto move up and down Aquickerway isto press B which changesthe cursorto and numbersmay now be entered directly using the number keys e g to enter405 firt press B then enter 405 The display will show LCD 4 When the display shows the required text press to acceptor press to abandon ROOM CCT 8 ROOM 485 ECT a2 44 T9790 amp TS900 User Manual Fault Finding Fault Finding Display Messages LCD ALARM 85 08 30 45 28404 AUX BELL TAMPER 08 30 45 28704 AUXILIARY 86 IV 08 38 45 28 84 A BATTERY FAULT 08 38 45 28 84 CCTS FAILED TEST 08 30 45 28704 CETS ISOLATED 08 30 45 28704 CODE TAMPER 1 88 38 45 28484 DELAY ALARM 05 n LU n g9 30 45 20704 DEL FIT OS ENTRY ALARM Ei 88 38 45 28 8
27. ERHBES Wards A B C or System Set SYSTEM OPEN 575 GPEN JP System fully unset SYSTEM RE ARMED RE ARMED F System rearmed all healthy circuits SYSTEM SET FULL SET System fully set TAMPER 01 56 TAMP R 01 55 5 Tamperalam from circuit TEST CCTS OFF TEST GFF All circuits taken off Test TEST FAIL 01 56 T FAIL 0 56 DB 1 5 Circuit failed during Test TIME CHANGED TIME CHG System time changed UNSET WARD A B C S UNSET F E C 5 1 Wards A B C or System Unset WALK TEST WALK TST System Walk Test selected 56 Panic Alam circuit activated 3 ka I Ts I Table 1b Log eventcodesand descriptions Remote Call Back 2 0 If youralarm system has been fitted with a modem the installation company can dial into the system and remotely read and write data from the control panel For added security the installation company can also program youralarm system so thata masteruserhasto authorise anywrite commands When Remote Call Back issetto Enabled the installation companycan dial into the system atany time and read and write data from the control panel When Remote Call BacK issetto Disabled the installation company can dial into the system at any time and only read data from the control panel Once a masteruserhasenabled Remote Call Back the system will automatic ally disable Remote Call Back after four hours 1 Ensure that User menu 2 is selec
28. T Tamper 18 TS790 amp TS900 User Manual User Menu 1 Remote Reset 1 3 This option allows the userto Reset the system afteran alarm by using a Remote Reset code The full procedure is explained in Resetting Afteran Alarm on page 12 Change Passcode 1 4 This option allows all users thathave accessto Usermenu 1 to change theirown passcode The master users can also add and delete user passcodes see Setup Users on page 25 1 Ensure that User menu 1 is selected LCD Starburst LED 1 H New code gt option The display will show 2 Enter your new passcode e g 1212 thanse Fass code E the display will show Hew code gt 1212 CU 3 Press to acceptthe new passcode a multi tone indicatesthatthe new passcode has been accepted and the display will automatically retum to Usermenu 1 Alow tone indicates that the passcode is not available Repeat again from 1 trying a different four digit number Enable Chime 1 5 Detection circuits that have been programmed as Chime by the installation company orthe master user will generate a two tone sound if activated This menu option allows the user to selectone of the five Chime options Disabled All detection circuits programmed as Chime will not generate a Chime tone when activated Enabled Alldetection circuits programmed as Chime wil generate a Chime tone when activated Enabled in P Set Alldetection circuits pr
29. code the alarm system will be full set afterthe pre programmed exit timer has expired The display at step 2 will count down the remaining ext time Final Exit Afterentering your passcode the alarm system will be full set afterthe Final Exit dooris opened and closed The display at step 2 will show a count of 9999 Exit Terminator Afterentering your passcode the alarm system will be full set afterthe Final Ext door is opened and closed and after pressing the Exit Teminator button a push button normally mounted outside of the premises The display at step 2 will Show a count of 9999 Instant After entering your passcode the alarm system will be full set after 5 seconds gt gt If an attempt ismade to full set the system whilst any circuits are active such asa door being open the display at sep 2 will indicate the circuit s thatare in fault and intemal sounder generates an interrupted tone The fault must be cleared before the setting procedure can be completed If the system issetby Timed Bt or Instant and the fault is still present at the end of the ext time an intemal alarm will be generated If fitted the extemal strobe light will flash indicating that the system has Failed to set To prevent this alarm simply re enter your passcode before the ext timer expires To full set the system proceed as follows LCD LED 1 Enter your passcode voo he mm EUNT TION display will show Select Functions TR OL 2 A
30. cuit 10 enter 10 the top line of the display shows the circuit text if programmed and the bottom TET O H line shows the status of the circuit e g CCT 18 Healthy 3 PressiJto leave this optionand retum to Usermenu 2 Set Clock 2 2 The system clock uses the 24hr format and provides event times for the system log as well as displaying the current time when the system is set or unset The clockis set as follows 1 Ensure that User menu 2 is selected alu LCD Press 2 to select the Set Clock option The Fe sess display will show 2 Enter the time using the number keys aA will show 3 Press to update with new time setting or press s abandon this option and retum to User menu 2 24 TS790 amp TS900 User Manual User Menu 2 Set Date 2 3 The system date isshown in day month format itis used to provide event datesin the system log and isnomallydisplayed LC Donly when the system issetorunset The date issetasfollows 1 Ensure that User menu 2 is selected Press 3 to select the Set Date option The Saarourst LED LCD 2 Enter the date using the number keys e g enter 2804 forthe date 28 APRII The eunu display will show PEDRO S 3 Press and the display will show 4 Select the day by pressing 1 for Sunday 5 for Thursday 2 forMonday 16 forFriday 3 forTuesday Z for Saturday 4 for Wednesday e g to select Wednesday press 4 the display will show
31. d the display i 1 ABC SECURITY 1 3 After 5 seconds the SYSTEM OPEN message will disappearand the display will show the time date and bannertext LCD only e g The Code Set Group passc odes may be used when the system isfully set When the passcode is entered only those wards assigned to the Code Set Group will be unset The following example shows how to unset wards A and Busing the passcode type Code Set Group A The example first assumes that the alarm system is initially full set TS790 amp TS900 User Manual Operating The System Part Setting With Part Set Passcodes Cont To unset your area s proceed as follows 1 Enter the area or premises via the LED Saarourst LED prescribed entry route and proceed directly to the remote keypad The intemalsounders generate an intemupted tone The display will showhow much time you have lefte g 2 Enteryour Code Set Group passcode ESE 3 3 C 2 within the enty time The 252 Sun 28 APR 7 TUNG Ant intemal sounders will stop and the display will show the wards that have remained set and the time e g The system may be retumed to the full set condition by re entering the Code Set Group passcode and leaving the area orpremises via the prescribed exit route The system may also be fully unset at any time by entering a valid passcode Master Standard or Holiday Code Set Group A Sets unsets wards Code Set Group B Sets unsets ward
32. e 34 Starburst LCD LED User menu 2 nr pos Select Ortion USER 5 View Circuits Enter CCT No gt our E BE Bes Ehe Bez eg Change Fasscode Hew code gt Alter Chime ccts crt n Enter CCT No gt TS et a Alter 24Hr Grour COT Enter CCT No gt LLI ut I Print System Log No events Configure Wards y ni Enter CCT Ho 5 nee oe PASSCODE 88 TI nmn Lt N LIE Remote Call Back Lt pieles Call Number 1 rA I mt 6181 12345678 LIILL Lief lt gt Menu options6 and 8are onlyavailable ifthe installation companyhasprogrammed the master users for full access 23 User Menu 2 TS790 amp T5900 User Manual View Circuits 2 1 Each detection circuit may be viewed to ascertain its status The circuit status conditions are Healthy H The nomal status of an alam circuit Active A The status of an activated alam circuit Tamper T The status ofa tampered circuit open circuit Shorted S Status of circuit which is shorted A shorted status is generated when a normally open device such as pressure pad or Ext Terminator is activated 1 Ensure that User menu 2 is selected LCD Starburst LED Press 1 to select the View Circuits option View Circuits rey H P Enter CCT No gt bee ot The display will show 2 Select the circuit by entering its number orby pressing A To move up one circuit B To move up ten circuits C To move down one circuit e g to view cir
33. e alarm system is unsetthe detection circuit may be triggered without causing an alam To intentionally exclude the monitoring of one or more detection Circuits when full or part setting the alarm system The state of the alarm system whenitis protecting partofthe premises 47 Fault Finding 19790 amp TS900 User Manual Passcode P A Panic Alarm Remote Keypad Reset Set System Open System Set Tamper 24 Hour C ircuit Unset Users Wards A unique four digit number which must be entered before the alam system can be operated Emergency push button switch used to activate an alam The alam signal will also be transmitted to the central station if a remote signalling device is fitted A device located away from the main contol panel that is used to operate the alarm system The action required to retum the system to its normal state after an alam To am the alam system or wards The normal unset state of the system The full set state of the alarm system An alarm caused by the system being interfered with physically orby too many unauthorised keypad entries A circuit that is monitored at all times When triggered in the unset condition a local alarm is generated Intemal sounders only When triggered in full or part set condition a full alarm is generated To disarm the alarm system orareas wards Persons allocated a passcode which allows them to operate the alarm system A group of detect
34. e display willshow rt 588 cules 3 Deselect the wards by pressing A for Ward A B for Ward B C for Ward C 0 for Ward S e g to unset wards A and B deselect Please confirm varisSand C he depay vil how BE EEE 4 When the display shows the required Maas rs c AAE and the display will show the wards that are To unset further wards assuming wards S and C are set 1 To unset another ward enter your passcode 2 2 The display will Gace show Please Confirm ERBEN fer 2 Select the ward s you require to unset unset c In e g to unsetward C deselect ward S The Wards set 5 1 DRAT GET display will show 3 When the display shows the required 85 58 sun 28 APR 7 ward s press The display will show the wards that are set 14 TS790 amp TS900 User Manual Operating The System To Set further Wards assuming ward A is set 5 s Starburst 1 To set other wards enter your passcode fisse 2 2 2 2 The display will show er 2 Deselect all wards so that the display Please Confirm allt Base a BLE shows Inset i k kK ok 3 Press and the display will show Please Confirm ES play sho Set S BC 5 Bt NOTE Ward A is not displayed asit is already set 4 Select the ward s you require to set e g to set wards B and C press O to Please Confirm pr deselect ward S The display will show SE Ee SE 5 When the display shows the required
35. entered Full alarm from circuit 01 56 Auxiliary tamper activated Fi za 5 i m mn Y za m AUX BELL TAMPER Au N co me Auxiliary circuit activated Battery fault voltage below 10 5V Extemal bell and strobes tested Modem making a call back to remote PC cr Ti r r 24Hr group omitted during the unset condition Circuits omitted by the user at time of Setting The number of circuits tested during Walk Test Code tamper from keypad 01 04 Plug on digicom active un m wi we co pa ce Plug on digicom failed to communicate Plug on digicom communicated successfully System Date changed DEFAULT CODE Userpassc ode 01 resetto 5678 bythe engineer DELAY ALARM 01 56 Delayed alam during a part set condition DURESS 01 31 Duress alarm from user passcode 01 31 ENTRY 01 56 7 Fn Entry timer started by circuit 01 56 ENTRY ALARM 01 56 ERU Entry timed out alam from circuit 01 56 FACTORY RESTART FACT RST Fr System Factory Restarted FIRE ALARM 01 56 RE GI 56 FRB Fire alarm circuit activated FIRST KNOCK 01 56 Fal The first activation of a Double Knock circuit FUSE BLOWN 01 Fao INACTIVE CCTS 01 56 IRD KEY POINT 01 56 5 LINE FAULT LINE RESTORED Control Panel 12V Auxiliary Fuse blown un we Inactive circuits during the Unset condition un we Key point opera
36. er menu 3 Code Set Group Operation Starburst LCD Code set Grour Enter Grour gt a5 ES CRRA a res GRP E53 Code set Grour A Will set CA J Code set Grour A A mm Will set A C1 I When the system is unset and a Code set Group passcode is entered the selected areas wards will set after the setting procedure is followed e g If Code set Group A is defined as above then when the passcode is entered it will set wards A and C If the system is fully setand the passcode is entered it will unset wardsA and C The Code set Group passc odesare programmed bythe masteruserwithin Usermenu 2 see page 25 40 TS790 amp TS900 User Manual User Menu 3 User Names TS900 Remote Keypads Only 3 4 This option allows the master user to assign up to seven characters of text against each user passcode When viewing the log users that have a name programmed appearin the event description e g PASSCODE Fred If the username is left blank the event description will show the user number e g PASSCODE 01 When this menu option is selected the keypad operates in a text mode see page 44 for full details To program the usernames proceed as follows LCD 1 Ensure that User menu 3 is selected Press 4 to select the User Name option The display will show pe a ts 2 Enterthe usernumber01 31 e g enter 01 foruser01 then press The display will show 3 Use the keypad keys to program text see
37. evice Forexample a room protected by a movement sensor may be Circuit 01 while a door protected by a magnetic contact may be Circuit 02 Digital Communicator Aremote signalling device fitted to the system which will transmit alarm status data via the telephone line to a dedicated central station A process which allows the alarm system to be remotely interogated and programmed via a computerand modem A means of entering a passcode which generates a silent alarm via the digicom if fitted to a central station The route for entering or leaving the protected premises when the system is being full or part set The doorordetectorthatis used forleaving and entering the premises A pre set time delay to allow the userto enter the protected premises and reach the remote keypad without causing an alam A record of system activity which is stored in a non volatile memory A pre set time delay to allow the userto leave the premises when the alam system is being set by the timed exit method An extemal push button switch required by some police forces which is used to set the system after leaving the premises The state of the alam system when it is protecting all wards The user s who are responsible for assigning new users to the alarm System A device fortransmitting and receiving data to and from a computer via the telephone line A detection circuit type that will generate a full alarm when the alam system isset When th
38. fter5 seconds the extsounderwill start 52 2 exit How Y 3 Leave via the prescribed exit route 4 The system is set when the exit time has expired on activation ofthe Final Ext c irc uit or pressing the Exit Terminator button as Sr the display will show 5 After 5 seconds the SYSTEM SET message will disappearand the display will e only e g Setting Mode Timed J Final Exit I Exit Terminator J Instant I Ext Time Operating The System TS790 amp TS900 User Manual Unsetting The System The unsetting of the alarm system can be performed from any remote keypad To unset your alarm system proceed as follows 1 Enter the premises via the prescribed entry route and proceed directly to the Gans LCD remote keypad The intemal sounders EEE ID nter Your Loge generate an intemupted tone The display ITime left gt ee25 2025 will show the remaining entry time e g 2 Enteryourpasscode 22 2 2 before will stop and the display will show 3 After 5 seconds the SYSTEM OPEN message will disappearand the display will show the time date and bannertext LCD peo eee only e g I amp Ifthe entry time is exceeded an alarm isgenerated from the intemal sounders and the Second Entry timerisstarted If atthe end of the Second Entry timer the alarm system hasnotbeen unseta full alarm condition will occur Ifthe installation companyhassetthe Second Entry timer to zero the
39. hasfailed Contact your installation company for further advice 45 Fault Finding TS790 amp TS900 User Manual Display Messages Cont PHONE LINE FAULT E 45 28704 PSU OVERLOAD 45 28704 The coverof Node 01 has been removed Referto Resetting After an Alarm on page 11 Mains powerto the system has been removed Enter a valid passcode to silence the alarm The system will be maintained from its standby battery fora minimum of 8 hours If the mains poweris not restored after 8 hours contact your installation company forfurther advice Panic alarm from detection circuit 08 Referto Resetting After an Alarm on page 11 Panic alarm generated by user 09 PA Code Refer to Resetting After an Alarm on page 11 Control panel coverhas been removed Referto Resetting After an Alarm on page 11 Telephone line fault systems fitted with remote signalling only To silence the alarm simply entera valid passcode If the fault persists contact your installation company forfurther advice The power supply within the control panel is being overloaded Entera valid passcode to silence the alarm and contact yourinstallation company for further advice Remote keypad 01 has been disconnected from the System or has failed Contact your installation company for further advice The cover of remote keypad 01 has been removed Refer to Resetting After an Alarm on page 11 Your system requires a service
40. ia a relay When this menu option is selected the keys function as follows 1 First ON time 2 Second ON time 3 Third ON time 4 First OFF time 5 Second OFF time 6 Third OFF time 7 Days of operation 1st 8 Days of operation 2nd 9 Days of operation 3rd en Set day 0 Toggle output ON OFF ss Escape A Select Time Switch A B Select Time Switch B C Select Time Switch C Selecting Time Switches When the Time Switch option is selected Time Switch A is automatically selected to select one of the other Time Switches proc eed as follows 1 Ensure that User menu 3 is selected Starburst LED Press n to select the Time Switch option m TIMER H The display will show 2 Selectthe Time Switch by pressing A for Time Switch A B for Time Switch B C for Time Switch C e g to select Time Switch B press a Setting The On Times To set the firt second and third ON times proceed as follows 1 Select the 1st 2nd or 3rd ON time LCD Starburst LED en 2 Enter the ON time in a 24Hr format e g enter 1700 for5 00 PM The display will show 3 Press to acceptthe time setting The fine suiten E TIMER B display will show Select Option IMIE 4 Repeat steps 2 and 3 for the second and third ON times as required 36 TS790 amp TS900 User Manual User Menu 3 Setting The Off Times To set the first second and third Off times proceed as follows
41. ion circuitsthatmaybe setorunsetindependently of each other 48 TS790 amp TS900 User Manual System Records User Record Set Unset Wa rds System Ward A Ward B User Type User Name 49 System Records 19790 amp TS900 User Manual Detection Circuit Record Circuit Circuit in Wards No Location Omit Chime System A B 50 TS790 amp T5900 User Manual System Records Detection Circuit Record Circ uit Circuit in Wards No Location Omit Chime System A B 51 Service Record Engineer Action Installation Information Bell Delay Bell Duration Master User Access Full Limited Remote Signalling Downloading Yes No User Authorisation Set with poweroff Yes No Set with Line Fault Installation Engineer Installation Company Address Telephone Central Station Telephone 18610 Drg 33 2179 00 Issue 01 Doc 02 November 1998
42. isplay will show 2 Select the circuit by entering its number orby pressing A To scroll up one circuit C To scroll down one circuit e g forcircuit 03 enter 03 The top line of the display will show the circuit tex if programmed and the bottom line shows whether the circuit is Armed or Omitted e g 3 Press B to toggle between Amed or Omitted If a low tone is generated when pressing B thenthe selected circuitcannot be omitted 4 When the display shows the required setting press to accept The display will show the next circ uit 5 If required repeat from step 2 forother circuits When finished press amp 3 If 24hr or Auxiliary circuits were selected the system will retum to the unset condition and the display will show 6 ff Nightcircuits were selected the system will retum to the User menu 1 and the display will show 7 The system can now be full or part set with the selected Night circuits omitted by pressing forfull set for part set A for part set B for part set C e g To full set the system press 0 and leave via the prescribed exit route The display will show IO AJ B CJ LCD Omit Circuits Enter CCT No gt Office Detector rr E CCT B3 Armed LL Office Detector ECT 3 n CCT Bi Omitted Leis L Store Room PIR FE Er CCT 84 Armed LL ECTS ISOLATED IF UST M UTI 63 38 Sun 28 APR LONE os IIMITTLITT MTT Ed ILI il 9933 Flease Exit Now Time left
43. larm system proceed as follows Starburst LCD LED 1 Enter your passcode 2 2 2 The Press ENT to DING TI display will show Select Function J LOL ETEN 2 Within 5 seconds press the required forpart set A The display will show 3 The ext sounder will start If necessary leave the area via the prescribed exit route HHA The display will show the remaining exttime 7 9225 sri e g 4 The system will be part set when the ext PART SET time has expired on activation of the Final Exit circ uit or by pressing the Exit Terminator Bez button as appropriate When the system is part set the display will show the wards that 16 40 I amp The tex shown on the LCD remote keypads at step 2 may be programmed by the master user see Edit Text for Part SetGroups on page 41 If the text is not programmed the display will read the default Part Set group A for the above example I amp Ifthe alam system has LED remote keypads fitted the installation company may have programmed the system so that the altemating displays shown at step 4 only show the time Part Set A Setting Mode Timed J Final Exit I Exit Terminator J Instant I Part Set B Setting Mode Timed Final Ext II Ext Terminator J Instant I Part Set C Setting Mode Timed Final Ext Jj Ext Terminator J Instant I Operating The System TS790 amp TS900 User Manual Part Setting With Part Set Passcodes Passc ode types Code Se
44. ng your alam system Cover Fold down cover with quick JJ guide operating instructions AR M Rs Operating The System Introduction Initial access to the system is gained by entering a 4 digit passcode Everytime you wish to use the system your passcode must be entered corectly If a passcode is repeatedly entered incorrectly a code tamperalam wil be generated Up to 31 separate userpasscodesare available foroperating the system The masteruser user 01 is the person responsible forallocating other users to the system Each user 02 31 may be defined for different authorisation levels See page 25 for full details the table below shows the code levels and their menu access Code level User Menu 1 User Menu 2 User Menu 3 Master v v v Standard v Holiday v SetOnly v Reset Only Options 1 9 only PA Code v Access Used foraccess control Full Set Group Code Set Group A Code Set Group B Code Set Group C Only allows setting and unsetting of selected wards Ifthe installation companyhasprogrammed the masteruserfor limited access he orshe will NOThave accessto User menu 2 options 6 and 8 and all options in User menu 3 User Menus In general when evera userpasscode is entered the system will enterinto a 5 second function mode if the button is pres
45. ogrammed as Chime wil generate a Chime tone when activated during the part set condition Enabled in Unset All detection circuits programmed as Chime will generate a Chime tone when activated during the unset condition Enabled o p AOn Alldetectioncircuitsprogrammed as Chime wil generate a Chime tone only when Custom O P A isactive Custom O P A is configured by the installation company and may be programmed to go active only when certain condition are true e g the output could be programmed to follow one of the Time Switch outputs thus allowing the chime to be enabled during a time window continued oven 19 User Menu 1 TS790 amp T5900 User Manual 1 Ensure that User menu 1 is selected LCD Starburst LED Press 5 to selectthe Enable Chime option The display will show ges 2 Select the chime option by pressing IO 0 Enabled Disa bled 1 Disabled OFF 2 Enabled ON 1 3 Enabled in P Set ON 2 4 Enabled in Unset ON 3 Enabled o p A On ON 4 BJ Toggles between options 1 5 e g to disable the Chime feature DEE press 1 the display will show 3 When the display shows the required setting press to accept The display will automatically retum to User menu 1 m ln Omit 24 Hour Group 1 6 The installation companyormasterusermay group togetherdetec tion circ uittypes 24 Houra nd Auxilia ry so that they can be omitted when the system
46. p TS900 User Manual User Menu 3 User Menu 3 Introduction This menu is only available to master users and is selected by pressing the ENT button whilst Usermenu 2 isselected There are sixmenu options within this menu which may be selected in any order The master user may leave this menu and retum to User menu 2 by pressing ESC button To select User menu 3 first ensure User menu 2 is selected then press the key The display shows 1 Time Switches page 36 2 Part Set Groups page 39 3 Code Set Groups page 40 4 Users Name page 41 5 Part Set Group Text page 41 6 Circuit Text page 42 3 View Inactive Circuits page 43 LCD Starburst LED User menu 3 mc Select rtion 1 USER 3 Time Switch A TIMED DL Select rtion 1 mo IE eH Part set Grour nm Dod Ee Enter Grour gt J 25 GRI Code set Grour 7 PE EDO er Edit Text For User Mo gt Edit Text For HEE Ie Edit Text For No Activity from 2 NM T gt Usermenu 3 is only available if the installation company has programmed the master users for full access 35 User Menu 3 TS790 amp TS900 User Manual Time Switch A B amp C 3 1 The TS790 TS900 system has three programmable Time Switch outputs A Band C Each output can be independently set with up to three separate on off times and made to operate on various days of the week These outputs may be used to contol intemal orextemal lighting v
47. page 44 When the displayshowsthe required text press to accept orpress J to abandon and retum to step 1 Repeat forthe other User Names or press J to retum to User menu 3 Edit Text For Part Set Groups TS900 Remote Keypads Only 3 5 When the system is being part set using the part set button A Bor C the display will show the default message of Part set group A Bor C This message can be changed using up to 32 characters e g Part set group A may be changed to Setting Office area only When this menu option is selected the keypad operates in a text mode see page 44 To program the part set text name proceed as follows LCD 1 Ensure that User menu 3 is selected Press 5 to select the Edit Text forPa rt SetG roups option The display will show 2 Select the Part set Group by pressing A for Part set Group A B for Part set Group B C for Part set Group C e g to select Part set Group A press A The display will show 3 Use the keypad keys to program text see page 44 When the display shows the required text press to accept The display will retum to step 1 Repeatforthe other Part set Groups or press s to retum to User menu 3 41 User Menu 3 TS790 amp TS900 User Manual Edit Circ uit Text TS900 Remote Keypad Only 3 6 Each detection circuit can have up to sixteen characters of text assigned to it e g circuit 01 may be programmed to
48. r Group page 20 7 Omit Circuits page 20 8 Silent Set page 22 9 View Activity Count page 22 _0 Full Set page 22 A 18 1C Part Set page 22 Sta rburst LED LCD User menu 1 n i Select rtion 1 USER Sounder ON gt B3 J Press ESC to end Walk Test Press ESC to end Remote Reset n Quote gt 5609 555 g E ze Chime ccts are n t Enabled LOG CCTS ISOLATED 65 38 Sun 28 APR Omit Circuits rr Mi Enter CCT No gt LLI LU Silent Set Enter Grour gt Activity Boca ree Press ESC to end LLL Please Exit How Please Exit How mnn Time left gt Baa LLLI 17 User Menu 1 TS790 amp T5900 User Manual Bell Test 1 1 This option allows the intemal sounders extemal bells and extemal strobe lights to be tested by the user When selected each device will operate in sequence for nine seconds 1 Ensure that User menu 1 is selected Press 1 to select the Bell Test option 2 The intemal soundens will operate for 9 seconds press to advance to the next test or s to end the test The display will count down the remaining time e g Starburst Sr ON gt 89 ae a Sr ESC to end ae FUN C Strobe ON gt 69 DN 5 Press ESC to end LU 3 The extemal bell s wil operate for 9 seconds press to advance to the next test or J to end the test The display will show the remaining on time e g 4 The extemal strobe s will operate for 9 seconds press to end
49. r is present Steady when mains power is present Red Function Indicator Can be programmed by the alam company to indicate a fault set or part set etc O Keyboard Used for operating your alam system Cover Fold down cover with quick guide operating instructions TS790 TS900 User Manual Overview Starburst Keypad The Starburst remote keypad can be used to full set partsetand unset the alarm system It also can be used for limited programming functions Starburst Display Used to show the OPEN M rie system time along with other system r messages Green Power Indicator Flashes if no mains power is present Steady when mains power is present Red Function Indicator Can be programmed by the alam company to indicate a fault set orpart set etc O Keyboard Used for operating your alam system Cover Fold down cover with quick guide operating instructions LCD Keypad The LCD remote keypad is a full function keypad and can be used to program test set and unset the alarm system o CF LCD Display Used to showthe system TW e time along with other system messages D Green Power Indicator Flashes if no mains power is present Steady when mains poweris present Red Function Indicator Can be programmed by the alarm company to indicate a fault set or part set etc Keyboard Used for operati
50. rd A Ward B Ward C Each ward can then be assigned to a passcode or part set button to allow flexible part set arrangements See Part Set Groups on page 39 and Code Set Groups on page 40 Only Night Final Ext and Exit terminator circ uittypes can be assigned to wards A Band C Circuits can be assigned to more than one ward A B or C thus creating overlapping areas Circuits that are assigned to more than one ward will only be armed when both orall wardsare set From the factory all detection circuits are assigned to the system ward i e they are not assigned to wardsA BorC Circuits that remain assigned to the system ward can also be setor unsetindependently See Part Set Groups on page 39 and Code SetGroups on page 40 1 Ensure that User menu 2 is selected Sam ES option The display will show 2 Enterthe circuit number e 9 forcircuit 02 enter 02 The top line of the display shows the circuit text if programmed and ers Rom PIR the bottom line shows the wards that the circuit are assigned to e g itn I I aoe L LL r 3 Select de select the wards by pressing A for Ward A B for Ward B C for Ward C 02 to wards A and B If a lowtone is Se generated when pressing the A B or rT 02 8 C then the selected circuit cannot Gd OG be programmed into wards r 4 Press to acceptand repeatfrom step 2 forothercircuits when finished pre
51. rt set buttons A BorC is pressed the display will show relevant Part set Text and after a short delay the system will only set the areas wards that are assigned to the selected Part set Group 39 User Menu 3 TS790 amp TS900 User Manual Code Set Groups 3 3 This option allowsthe userpasscode types Code Set Group A Code Set Group B Code Set Group C and Full Set Group to be defined so that each may Set or Unset any combination of Wards A Band C and the System Ward e g Code Set Group A may be defined to Stand Unset Wards A and Bonly and Code Set Group B defined to Stand Unset Wards B C and the system etc 1 Ensure that User menu 3 is selected Press 3 to select the Code Set Groups option The display will show 2 Select the Code set group by pressing A To select Code set Group A B To select Code set Group B C To select Code set Group C 0 To select Full set Group e g To select Code set Group A press A The display will show 3 Select de select the wards by pressing 0 To select de select Ward S A To select de select Ward A B To select de select Ward B C To select de select Ward C e g to add Ward C press C The display will show 4 When the display shows the required setting press v to accept The display will retum to step 1 repeatforthe other Code set Groups or press s to retum to Us
52. rtext LCD only e g Your alarm system is reset by User Q Engineer J Remote Reset Continued Over 11 Operating The System Engineer Reset TS790 amp T5900 User Manual From step 3 of Unsetting After An Alarm proceed as follows 1 The display will cycle between the detection circ uitthatcaused the alarm and the CALL ENGINEER TO RESET SYSTEM The system will also beep every minute to indicate the system requires an engineerto reset the system To silence the beeps simply enter your passcode 2 2 2 2 Call the installation company to attend and reset yoursystem LCD Starburst LED ALARM 3 DUM n Office Detector NEL 09 45 55 28704 LU PF gU CALL ENSINEER TO can RESET SYSTEM LIILL De ENGINEER I amp The display shown at step 2 is programmable and may show something different Remote Reset From step 3 of Unsetting After An Alarm proceed as follows 1 Follow Step 1 of the Engineer Reset procedure 2 Enter your passcode A 2 The display will show 3 Within 5 secondspress J UserMenu 1 is selected the display will show 4 Press 3 to select the Remote Reset option The display will show a random four digit Seed Code e g 5 Wite down the Seed Code Telephone your central station and quote the Seed Code You will be asked to report the circumstances of the alam If an engineer is not required to attend site you will be given a unique fo
53. s Code Set Group C Sets unsets wards Full Set Group Sets unsets wards Operating The System TS790 amp TS900 User Manual Silent Setting The alarm system may be full orpart set such that the intemal sounders are switched off during the exit proc edure Howeverthe system will give a shorttone atthe end of the ext procedure to indicate that the system has successfully set To fullset the alarm system silently proceed as follows Starburst LCD LED 1 Enter your passcode 2 2 2 2 the mA FUNETIB display will show Select Functions LIT UL 2 Within 5 seconds press 8 The display 3 Leave via the prescribed ext route 4 The system is full set when the ext time has expired on activation of the Final Ext circuit or by pressing the Ext Terminator button as appropriate To part setthe alarm system silently proceed as follows Starburst LCD LED 1 Enter your passcode 2 2 The FLING TION display will show Select Function 2 Within 5 seconds press the required SS part set button AJ B or C e g press A ESSET for part set A then press 8 The display will show 3 Leave the area or premises via the prescribed ext route 4 The system is part set when the exit time has expired on activation of the Final Ext circuit or by pressing the Ext Terminator button as appropriate 10 TS790 amp T5900 User Manual Operating The System Unsetting After An Alarm
54. sed during thistime Usermenu 1 isselected asa reminder a brief description of each menu option within Usermenu 1 is printed undemeath each button onthe the remote keypads e g button 1 selects the Bell Test option If the button is not pressed within 5 seconds the system will attempt to full set When anyof the menu optionsare selected the usermay abandon the function by pressing the ss button If the s button is repeatedly pressed whilst one of the user menus is selected the alarm system will retum to the normal OPEN condition Engineer on Site Message When the installation engineer attends the site for routine maintenance etc the remote keypads may show Engineer on site EM ON 5 IEE whilst this message is displayed the alam system remains fully operational However before the engineerleaves the site he should ask one of the users to entertheir passcode followed by 4 this will clearthe Engineer on site message and retum the system to the nomal OPEN condition 4 TS790 amp TS900 User Manual Operating The System Full Setting The System The full setting procedure may be initiated from any remote keypad if more than one is fitted Before attempting to full set the alarm system ensure that all movement detectors are unobstucted and all doors and windows are secure The installation company will have set up youra lam system to full setbyone ofthe following Timed Exit Afterentering your pass
55. select the View Log option The display will show the most recent event see Table 1 e g 2 Use the A or keys to scroll backvardsand the C key to scroll forwards through the log e g enter A to scroll backwards The display shows the previous evente g 3 To viewthe time forthe selected event press B once The display shows the time that the event occured e g 08 45 am 4 To view the date forthe selected event press B again The display shows the date that the event occuned e g 28 APRII 5 To view the minutes and seconds forthe selected event press B again The display showsthe minutesand seconds that the event occurred e g 40 mins amp 59 secs 6 To view the event description again for the selected event press B again The display shows the event description again e g 7 Press to leave this option and retum to Usermenu 2 Starburst LED 31 User Menu 2 TS790 amp T5900 User Manual ACTION ALARM ALM SENT AC OFF AL GFF AC RESTORED RE GI ACCESS 01 31 cC 55 r3 ALARM 01 56 ALARM Bi 55 TANP AUXILIARY 01 56 UX ai 5 BATTERY FAULT BELL TESTED CALL BACK No 01 03 CCTS ISOLATED CCT OMITTED CIRCUITS TESTED 01 56 CODE TAMPER COMMS ACTIVE COMMS FAILED COMMS SUCCESSFUL DATE CHANGED Alam activated when system is part set Mains power removed oy ou a m Mains power restored za n co uo Access user passcode 01 31
56. six Chime options See Enable Chime on page 19 1 Ensure that User menu 2 is selected LCD LED Press 5 to select the Alter Chime Circuits option The display will show 2 Select the circuit by entering its numberor by pressing A To move up one circuit To move down one circuit 3 e g forcircuitO7 enter 07 the top line of the display shows the circuit text if Den es M m s ies whetherthe circ uitis selected as Chime or Silent e g 4 4 Press B to toggle between Chime and Silent f a lowtone isgenerated when Entrance Door a_r pressing B thenthe selected circuitcannot CeT 87 chine MES be programmed as Chime r4 SE eu 5 Repeat from step 2 for other circuits when finished press to abandon this option and retum User menu 2 Alter 24Hr Group 2 6 Detection circuits types 24H and Auxiliary can be grouped together so that if required the users can omit the group when the system is unset 1 Ensure that User menu 2 is selected ICD Starburst LED Press 6 to select the Alter 24hr Group option The display will show 2 Select the circuit by entering its number or by pressing A To move up one circuit C To move down one circuit e g forcircuit 10 enter 10 the top line of the display shows the circuit text if programmed and the bottom line uc Loading Bas Door EET d m shows whetherthe circuit is selected as Amed or Omitted e g
57. ss E39 to abandon this option and retum User menu 2 30 TS790 amp TS900 User Manual User Menu 2 Viewing the System Log with an LCD Remote Keypad 2 9 To view the log with an LCD remote keypad proceed as follows 1 Ensure that User menu 2 is selected Press 9 to select the View Log option The display shows the most recent event The top line shows the event description see Table 1 and the bottom line shows the time and the date that the event occuned one g 2 Use the AJ or keysto scroll backwardsand the C key to scroll forwards through the log e g enter A to scroll backwards The display shows the previous event e g 3 If the event being displayed is one that refers to a user number e g PASSC ODE 01 Pressing the B key will toggle between the user text name and user number for that event 4 Ifthe event being displayed is one that refers to a circuit number e g ALARM 02 Pressing the B key will toggle between the circuit number and circuit text for that event 5 Press to leave thisoption and retum to Usermenu 2 LCD PASSCODE 1 08 45 59 28 784 PASSCODE 61 08 40 59 28704 PASSCODE Colin PASSCODE 1 08 40 59 28 84 08 40 59 28 704 ALARM 62 Store Room PIR 06 00 59 28 84 06 00 59 28 04 Viewing The Log With an LED or Starburst Remote Keypad 2 9 To view the log with an LED or Starburst remote keypad proceed as follows 1 Ensure that Usermenu 2 is selected Press 9 to
58. tGroup A Code Set Group B Code SetGroup C and the Full Set Group enable the userto setand unset only the wards assigned to their Code Set Group The Code Set Groups are configured by the master user or installation company see Code Set Groups on page 40 The following example shows how to set and unset wards A and Busing the passcode type Code Set Group A The example first assumes that the alarm system is initially unset To set yourarea s using a Code Set Group passcode proceed as follows 1 Enter your Code Set Group passcode Starburst LED LCD 2 2 2 2 The exit sounder will start If Please Exit Now nnazc necessary leave the area via the prescribed exit route The display will show the remaining exit time e g 2 The system is partset when the exttime PORT SET has expired on activation of the Final Exit circuit or by pressing the Ext Terminator button as appropriate When the system 4 has part set the display will show the wards AGA that are setand the time e g To unset your area s proceed as follows LCD Sarburst Y Enter the area or premises via the Fee nes prescribed entry route and proceed directly to the remote keypad The intemalsounders generate an interupted tone The display LED will show the remaining entry time e g SYSTEM OPEN 2 Enter your Code Set Group passcode 2 2 2 within the entry time The intemal sounders will stop an
59. ted an Starburst LED Press 0 to select the Remote Call Back option The display will show 2 Press B to toggle between Enabled Yes and Disabled No Press to update with new setting or press abandon this option and retum to User menu 2 33 User Menu 2 TS790 amp T5900 User Manual Initiate Remote Service Call 2 A If youralarm system is fitted with a modem itis possible fora master userto initiate an upload sequence to a remote site normally the alam company or central station Once the communication link is established the remote site can read and write data from the control panel This feature is only compatible with Menvier Lineload software version 2 0 orabove lt gt Only select this option when requested by the installation company if this option is selected without authorisation from the installation company the modem may not connect with the remote site To initiate a Remote Service Call proceed as follows 1 Ensure that User menu 2 is selected Starburst LCD LED Press A to select the Initiate Remote Call Number 1 roy NI Service Call option The display will show B19 17545678 Suse 2 Select the telephone number you require to call by pressing 1 to call number1 2 to call number2 3 to call number 3 p wu Call Number 2 re m The display will show 3 Press to initiate the upload sequence to the remote site or press to abandon this option 34 TS790 am
60. tion from circuit 01 56 Telephone line fault detected Telephone line fault restored MODEM LOCK OUT Modem failed to communicate NO EVENT No log event NODE ADDED 01 05 Node added to the system NODE FUSE 01 05 Node fuse blown NODE REMOVED 01 05 Node removed from the system NODE TAMPER 01 05 Node cover removed ON SITE RESTART System On Site restart OMITS REMOVED Previously omitted circ uits reinstated Table 1a Log event codes and descriptions 32 TS790 amp TS900 User Manual User Menu 2 Sta rb urst Description PA ALARM 01 56 PRALM Gi 56 PRO PA CODE 01 31 PANE G 56 PED Panic Alarm passcode entered PANEL LID TAMPER LB TRAP LE Control panel lid removed PART SET A B C FSET RABE P H h L System Part Setusing one ofthe A B orC buttons PASSCODE 00 31 USER GG 3H UrGO 31 Userpasscode entered 00 31 REMOTE ADDED 01 04 R ADO Gi G4 AO I 04 Remote Keypad added to the system REMOTE RESET REM RST System reset by Remote Reset passcode REM REMOVED 01 04 R REM Gi OH BI Remote Keypad removed from system REM SERVICE CALL R 5 CALL Remote service callvia Lineload software and PC REM TAMPER 01 04 R TMP Gi O4 BI Remote Keypad cover removed SERVICE CALL END RS END SE Remote service call finished SERVICE REQUIRED SERVIC Service required SET FAIL SET FAIL System failed to Set SET WARD A B C S a SET ABS S
61. ur digit Remote Reset code 6 Enterthe fourdigit Remote Reset code 2 2 then press Amuti tone beep will confirm acceptance and the display will retum to UserMenu 1 7 Press esd to retum to the Unset condition the display will show 8 After 5 seconds the SYSTEM OPEN message will disappearand the display will show the time date and bannertext LCD only e 9 LCD Starburst LED Press ENT to CUNT TUN gt e Select Functions TION F uut User menu 1 SER an Select Ortion LEN A Remote Reset Quote gt 6846 58 55 MEE HEL Remote Reset Reply gt User menu 1 Mt quom Select rtion 1 USER I Be SYSTEM OPEN noc 99 38 Sun 28 APR UPEN ABC Security na 88 30 Sun 28 APR Dato LE 12 TS790 amp TS900 User Manual Operating The System Setting individual Wards with Standard User Passcodes The installation company can enable certain standard users to have access to the Ward Selection Menu This feature allows the userto select the wards that they require to set at the time of setting the alarm system The following example shows how to set wards Band C LCD Starburst LED 1 Enter your passcode 2 2 The Frese ent to PUNTA display will show Select Functions L0 te rend 2 Selectthe setting option as follows A PartsetA B PartsetB C PartsetC 0 Ward Selection Menu NOTE If an option is not selected after 5 secondsthe system will attempt to full set
62. use 3 Selecta new usertype by pressing 4 Master 1 PA Code 2 Standard 8 Access 3 Holiday 9 Full set group 4 SetOnly A Code setgrp A 5 Reset Only B Code set grp B 6 Duress Code set grp C e g to select usertype Standard press 2 The display will show 4 When the display shows the required usertype press to accept The display will show 5 Entera 4 digitpasscode forthe selected user e g enter 2580 The display will show 6 Press to update with new passcode a multi tone will indicate that the passcode has been accepted and the display will retum to step 1 Alowtone indicates thatthe passcode isnotavailable Re enter trying a different 4 digit passcode 7 Repeat from step 1 for other users or press to retum to User menu 2 Starburst LED LCD USER Ea User No gt ut 4 Alter user tyre Nm rmm Hot in use vum Lt Alter user ture Ti rni n Standard S LU ANDARD Change Fass code New code gt Change Fass code Hew code gt 2588 coo I amp To delete user passcodes 02 31 from the system select the user number you wish to delete at sep 2 then enter your own passcode at step 5 27 User Menu 2 TS790 amp T5900 User Manual Alter Chime Circuits 2 5 This menu option allows the master users to select which detection circuits are designated as Chime Once programmed as Chime allusersthathave accessto Usermenu 1 can select one of the