1. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LEADER L GHT professional lighting products LL STAGE SPOT VARIO OPTIC ithout optic TR E11 p ae COMPLIMENTS ON YOUR PURCHASE All dimensions are in millimeters 215 j l Following items are included 1 LL STAGE SPOT VO without optic LL STAGE SPOT 16 RGBA without optic 1 pc PowerCon type A B 1 pc User manual 1 pc 2 LL STAGE SPOT VO with optic LL STAGE SPOT 16 RGBA without optic 1 pe LLVARIO OPTIC SPOT 16 25 1 pe PowerCon type A B 1 pc User manual Tipe Additional items needed Data cables with XLR 5pin Female Male 1 pc Controller compatible with DMX 1 pc Mounting accessories as necessary Surface mounting Screws and washers 1xM12 or 2xM10 Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 02 2 Back panel 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Connecting to AC power 03 4 Control data connecting 03 5 DMX channels 04 MAINTENANCE ENVIRONMENT RY Do not throw away the appliance with the normal household waste at the end GY of its life but hand it in at an official collection point for recycling By doing this you help to preserve the envir
2. 2 Vario Optic installation It is not necessary to open the fixture for echange of Vario Optic LL VARIO OPTIC SPOT 16 The optic installation is easy and fast by 1 screw Carefully remove the optic modul and insert the new one and fix with screw 2 1 If you have any question please contact su leaderlight sk LL36 202 LL STAGE SPOT 16 RGBA VO 25 LL36 203 LL STAGE SPOT 16 RGBA without optic Accessories LL37 190 LL VARIO OPTIC SPOT 16 10 LL37 191 LL VARIO OPTIC SPOT 16 25 LL37 192 LL VARIO OPTIC SPOT 16 40 LL37 193 LL VARIO OPTIC SPOT 16 EL Eliptical 15 x90
3. igital signal POWER Red alternate blinking Autotest function DATA Green 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters luminaries clamps cables Hairbreadth from combustible materials is 0 5m Before physical installation insert the optic modul on front of luminary The optic installation is easy and fast by 1 screw figure Nr 2 1 03 3 Connecting to AC power To tackle all Safety Information 01 For protection from electric shock the device must be grounded earthed It is not necessary to open the fixture before power supply Power supply is solved simple with Neutrik PowerCon connectors The fixture is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 260V Cord plug connections Wire Colour Screw US L live brown yellow or brass N neutral blue silver ground earth yellow green green 03 4 Control data connecting Control data cable length is specified by Norm IEC929 Annex E4 It is not necessary to open the fixture before c
4. onment MMxX Leader Light All right reserved 01 SAFETY INFORMATION WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done only by a qualified professional in accordance with relevant local codes 01 1 Risk of eyes damage Do not look directly into LED lamps Do not look into light beam from a distance of less than 40 cm 16 inches 01 2 Protection from electric shock Shut down power before installation or maintenance Luminaries and recommended AC power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of AC power and frequency that complies with local building and electrical codes to use Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the warranty Before removing or installing any cover or part of appliance disconnect it from AC power Appliance always connect to earth eltech 01 3 Fire prevention Follow all safety consideration A Thermostatic switches or fuses never to bypass Device never shield Around the axis of the fitting 180 must be maintained space for cooling Minimum distance from the surrounding objects must be 100mm 4 in figure 1 1 LEDs never direc
5. onnecting of DMX512 control signal Interconnections are realized by Neutrik XLR 5pin IN Out connectors Pin connections Pin 1 ground Pin 2 signal negative Pin 3 signal positive If you have any question please contact support leaderlight sk 03 5 DMX channels subject to change The latest version of DMX channels appendix are on the websites www leaderlight eu Amber Ultra soft curve Master Dip1 On Strobo Dip1 On 04 MAINTENANCE i To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coverd by warranty Regular cleaning is demand dust dirt Maintenance policy Unplug mains before maintenance and at least 10 minutes cool off Appliance do not illegal open or demount Clean up dust only from outer surface for ex scuttle diffuser and lenses Use vacuum or dumpy duster warm water Before reinstalling to check failure free state no wet parts INSTALLATION SPACE Ventilation space 180 free minimal 80mm Ventilation space 90 free minimal Minimal mounting distance from surface Surface installation Screw the fixture to the surface M12 or 2xM10 Ws AIMING POSSIBILITY The fixture could be aim to wish position with bracket Unfix by hand the screw and aim the fixture to the wish position and fix 1
6. t cover with filters or other materials Allowing max ambient temperature is 40 C 104 F Luminaries never use without mounting brackets The housing never install directly to the surface WARNING UMMM VILLAS ALLL bd Non minimum distance and or non use the original brackets is at your own risk 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type 16xRGBA OneChip LED Lifetime Long 60 000 hrs 90 degradation Vario Optic 10 25 40 and EL Eliptical 15 x90 Control data connection DMX 512 In Out with 5pin XLR Input power 150W Power connection 100 260V AC In Out PowerCon Net weight 3kg IP IP20 Ambient temp Ta Maximum 40 C Cooling Conventional Materials and finish Housing powder painted anodized aluminium in black other colours on request Installation Surface mounting Note LED Ii RGBA Red and Green and Blue and Amber Edition A 2010 02 2 Back panel DMX Out DMXin Power In XLR 5pin XLR 5pin PowerCon Control LEDs Dip options 100 10 1 Rotating DIP address 000 511 POWER DATA Control LEDs Indication INDICATION blinking 2Hz light off STATUS OK inside fixture is everything correct NO DMX8512 signal POWER Red DATA Green DATA Green blinking 4Hz OK income correct DMX512 signal DATA Green fast blinking NON correct d

Download Pdf Manuals

image

Related Search

Related Contents

Tunturi C525i User's Manual  Stratos®Pro A2... CONDI Betriebsanleitung    L`été se fête - Mairie de Fouesnant – les Glénan  SVAT Electronics qxd600 User's Manual  Ficha de Dados de Segurança CANETAS DE COLORAÇÃO  Encargado del Fondo Circulante    Tristar Air conditioner  Protein skimmer user manual  