Home

Advanced Installation & User Manual

image

Contents

1. Try to keep the extension cable as short as possible as the signal strength from the sensor is very low 11 4 Installation Settings Once the unit is wired SOLARIMMERSION IV has to be configured with the parameters required for the particular installation type used By default for simple installations with a single heater the only configuration requirements are listed below Follow the steps below to calibrate and setup the unit Step 1 Turn off the PV or micro generation system This is to make sure power is only imported which is essential for sensor clip calibration Step 2 Turn on SOLARIMMERSION IV unit Step 3 Turn on a high load like a kettle or a 2kW heater to make sure power is imported and wait for 5 seconds 3a If the sensor clip is installed correctly the display will be as below with the ASTERISK symbol Blinking 3b If the display is as below then you have to swap the wiring on the CT sensor terminals Once the terminals are swapped restart the switch and make sure the display is as picture 3a 5 LOAD 1 Step 4 Set the correct time amp software settings according to the wiring mode selected Please see section 5 Using Menu Controls and Internal Clock setting the time in Appendix 1 Step 5 Turn the PV inverter back on That completes the installation and SOLARIMMERSION IV should now start to divert any surplus power if available to the immersion heater or the connect
2. V input supply from 16A MCB 13A fused outlet N Neutral 2 Mains Neutral All neutral terminals internally connected E Earth 3 Main Earth Relay Terminals Terminal Description Normally open relay terminal NO Common relay terminal Normally closed relay terminal All relay terminals are volt free and max current is 16A Sensor Terminal Terminal Description CT AC current sensor clamp terminal CT AC current sensor clamp terminal Wiring Diagrams amp Software Setup Single Load System For single heater control no relay terminal wirings are required as the secondary load options is not used The default factory settings of the SOLARIMMERSION IV are optimised for a single heater configuration This keeps the installation simple as the only menu setting required is setting the time MAINS SUPPLY 16A MCB IMMERSION HEATER HENLEY BLOCK T1 NCCOMNO OP L L L RELAY POWER IX SOE _ OOO OMANIN Clip on CT UTILITY METER The default factory settings of the switch is configured for single heater system So no setting changes are required other than setting up the time If any settings were changed before please do a factory reset of the switch via the menu controls Dual Load System consumeRUNT MAINS SUPPLY 16A MCB IMMERSION HEATER 1 IMMERSION HEATER 2 HENLEY BLOCK 300 SOO 000000207
3. lL TUL CT NCCOMNO OP L L L RELAY POWER Clip on CT UTILITY METER With a single Load system the surplus will flow back to the grid once the water is hot and the thermostat cuts off This could be avoided using a dual heater system The secondary load LOAD 2 will be turned on when the primary load s LOAD 1 thermostat is cut off This improves the efficiency of the system Menu Settings for Single Load and Dual Load systems Set time LStepno Button Action Display m NN uu Time Time qM Time Clock Menu Set secondary load DT Dii 2 cam mE 2 30 mins option 60mins Press again Eur Load 2 for 30 mins 60mins 10 Menu Item Displayed Remarks Secondary Load Status Enabled Enable the secondary load Secondary Load Time 30 or60 long the secondary load should run Minutes before switching back to primary load Example Scenario for dual system The secondary load will be activated 3 minutes after the thermostat in the immersion cuts off amp there is surplus power 1 The primary load thermostat cuts off 2 The system has a surplus of 1000w at the point when the primary load cuts off 3 The system still maintains 1000W surplus after 20 minutes If the Load time is set to 60 the unit will deactivate LOAD 2 after 1 hour and activate LOAD
4. 1 If the LOAD 2 thermostat is still at cut stage the LOAD 2 will be activated after 20 minutes and the whole cycle will continue Sensor Clip Installation The correct installation and positioning of the current sensor clip is very important for the efficient operation of SOLARIMMERSION IV Wrongly installing the sensor clip could result in importing of power and the user incurring additional costs for electricity The sensor clip should be installed at the main incoming grid supply to the building which could be from the utility electricity meter Please note it is Utility Electricity meter NOT the PV generation meter Close the clip around the Live or Neutral cable from the utility electricity meter Please ensure the sensor clip is positioned nearest to the utility electricity meter as possible Only open a consumer unit if you are qualified to do so or are an experienced electrician If there is more than one consumer unit the clip must be positioned at the primary income source before it splits IMPORTANT SENSOR CLIP HAS TO BE ON THE UTLITY ELECTRICITY METER TAILS AND ALWAYS ENSURE THE CLIP IS CLOSED SECURELY AROUND THE CABLE Connect the clamp wire to the terminals inside SOLARIMMERSION IV If the sensor clip cable is not long enough it can be extended up to 50m but this must be done using a double twisted pair cable in order to stop any possible interference and a firm connection to the original cable is required
5. Solarlmmersion Use 100 of Solar PV Surplus SOLARIMMERSION IV Advanced Installation Manual v1 2 Contents Technical Specifications Mounting Clamp Installation Installation Settings Support amp Warranty Safety Notes Potentially dangerous High Voltages are present and therefore this equipment should only be installed by a qualified person Connect the equipment according to the correct IEE regulations and separate all wiring according to 1010 Make sure all screw terminals are tight before you switch the equipment on The terminal screw is rated 0 5Nem torque Do not touch any circuitry after you have connected the equipment due to potentially lethal voltages on the circuit board or connector terminals Equipment designed for Pollution Degree 2 environments only This means you must install it in a clean dry environment Overview SOLARIMMERSION IV is an intelligent surplus power control system for your PV system It diverts surplus power which would normally be exported to the grid When the unit is connected to an immersion heater it can heat water for free using the surplus power SOLARIMMERSION IV Highlights e Heats water using surplus power from all sorts of micro generation systems wind turbines hydro power e Keeps exported power as close to zero as possible by adjusting power levels to the immersion heater e Single sensor clip e LCD display for easy control and m
6. URN TO THE DEFAULT HOME DISPLAY AFTER SAVING THE VALUE USE ESC BUTTON AT ANY TIME TO RETURN TO THE HOME SCREEN AND RETAIN THE NORMAL OPERATION OF THE SWITCH LCD BACKLIGHT TURNS OFF AFTER 5 MIN TO SAVE ENERGY PRESS ANY BUTTON TO TURN ON THE BACKLIGHT AGAIN ALL MENU BUTTON OPERATIONS EXCEPT OVR SHOULD END BY PRESSING ESC 14 Appendix 1 Menu Options amp Controls Full List 1 Internal Clock setting the time Stepno Button Action E Time Time me Time Clock Menu 2 Override Button Setting the override function Stepno Button Action IE Override pn Menu 3 Set Auto Boost Setting the auto boost function Stepno 1 Button Action E 7 ESC to exit if only 1 Auto Boost Set Auto Boost 1 Menu setting required OR OR Set Auto Boost 2 Menu to set Auto Boost 2 repeat Set Auto Boost 1 menu if setting a second steps Auto Boost required 16 4 Load 2 Setting the secondary load Step no Button Action Display EE 2 30 mins option For 60mins Press T again Load 2 Enabled for 30 mins 60mins 8 Factory Reset setting the unit to factory settings Factory Reset Factory Reset confirmation ae Unit resetting to Factory settings 17 Support User Installation query Consult a qualified installer electrician Technical support for qu
7. alified installers and electricians please call us on 0845 519 8729 Online Support System If you require any assistance please submit your query to the Technical Support team via the link shown below http solarimmersion co uk solarimmersion support technical support Warranty Amelec Instruments Ltd warranty provides free repair or replacement cover for all faulty in parts and workmanship for 24 months from the date of purchase Amelec Instruments Ltd obligation is limited to replacing parts which have been reported promptly and are so found by Amelec Instruments Ltd upon inspection A valid proof of purchase is required if making a warranty claim Warranty is void in the event of improper accidental damage unauthorised service use of unauthorised components misuse natural disasters including lightning strike This warranty does not extend to ancillary equipment not supplied by the manufacturer No responsibility is assumed for incidental damage No responsibility is assumed for consequential damage Faulty parts Unit must be returned by prepaid post and accompanied by a Returns number available in advance from online ticket system 18
8. anagement of the unit e No need to change immersion heater or the tank e No manual intervention required to use surplus power e Built in override and boost timer functions to an immersion heater manually if required e Low threshold levels meaning less wasted power e Diverts as little as 20W of surplus power e Built in multifunction relay for Second load e Internal thermal protection e Multiple loads available 2 Technical Specifications Weight Dimensions Weight 650g 200mm Mounting holes centre 175mm 65mm Electrical Specifications Description Min Nominal Supply Voltage VAC 220 240 260 Supply Frequency 45Hz 50Hz 55Hz Hz Load Current A 13 16 Load Size kW 3 4 Relay Contact 250 Voltage VAC Relay Contact 1 1 Current A B Clamp Current 100 PV System Size W 500 4000 No Max Operating 5 20 40 Temperature C 3 Installation Mounting To keep the installation quick and easy we recommend that SOLARIMMERSION IV is installed near to the consumer unit as most of the connections required can usually be found there When choosing a suitable place to install SOLARIMMERSION IV the following should be considered e Near the main incoming mains supply of the property Access to the immersion heater supply cable normally in the consumer unit e Access to suitable supply via 16A MCB or 13A fused outlet e Ease of access and visibility of the SOLARIMMERSION IV LCD Screen and c
9. ed load 12 5 Using Menu Controls amp Setting Time When you have turned on the unit the default home screen will appear as shown in the imagine below This is the screen you will return to every time you press the ESC button Current time Sun symbol constant Load diverting indicator Surplus Energy available Current Load divert active This will be LOAD 2 when the secondary Sun symbol Blinking load is activated No surplus available divert on hold There are FIVE control buttons underneath the LCD screen Override OVR to activate the Override function Hold for 2 seconds to activate Up to navigate through the Menu Sub Menu options to increase values Down J to navigate through the Menu Sub Menu options or to decrease values Enter ENT to select a Menu option or save new values Escape ESC to cancel an action and return to the default home screen Yellow LED Power ON indicator 13 Within the main menu there are 5 options which are listed below Internal Clock Override Button Set Auto Boost Load 2 Factory Reset 0O A O N IMPORTANT TO ACTIVATE THE MAIN MENU PRESS THE ENT OR ESC BUTTON USE UP OR DOWN BUTTONS TO MOVE BETWEEN THE MENU OPTIONS TO SELECT A MENU OPTION TO CHANGE PRESS ENT BUTTON ONCE THE CORRECT VALUE IS SELECTED USING THE UP AND DOWN BUTTONS PRESS ENT BUTTON TO SAVE THE VALUE THE SCREEN WILL RET
10. ontrol buttons e Good ventilation to keep air flowing through the unit at least 100mm around the unit e Suitable cable access point location through the top of the unit Secure the SOLARIMMERSION IV to the wall with the two screws or using suitable fixings for the surface type Electrical Installation Electrical connection should only be made by a qualified person Please do not attempt to install SOLARIMMERSION IV unless you hold such qualifications or are an experienced electrician Alterations to fixed wiring and or opening the consumer unit may be required risk of death by electrocution Locate the most appropriate cable access point at top of the unit to make connections to the unit according to the wiring diagram Loads The proportionally controlled primary and secondary loads connected alone or combined should not exceed 3kW The load should not include digital circuits as they may be affected by the modulated output from the SOLARIMMERSION IV The relay terminals could be used to drive small inductive or resistive load when LOAD 2 is enabled Terminals Make sure the wiring cables are securely connected and fully tightened with the rising clamp terminals The terminal screw is rated 0 5Nem torque Failure to do so can result in fire or the SOLARIMMERSION IV unit being damaged Power Terminals Terminal Description 9 Proportional output to the load Max 3kW L Live 2 Main Live 240

Download Pdf Manuals

image

Related Search

Related Contents

TP-Link Archer C9 Data Sheet  Korky 54CM Instructions / Assembly  6・7ページ(PDFファイル:510KB)  EUROLIVE F1320D  POLYTEST Product User Manual - Ray  CARACTÉRISTIQUES • Cellules « intelligentes  Cooper Lighting LUMARK Impact Wall Medium User's Manual    Manual de usuario de la aplicación eDCS - Medio Ambiente  Severin AT2515 toaster  